HomeMy WebLinkAboutCompaction TestHeadquarters 11345 U.S. Highway 1 Ar Sebastian, FL. 32958 &J ILVAB Orlando 723 Progress Way Sanford, FL. 32771 June 7, 2021 CONTRACTOR: JOB LOCATION: PERMIT #: To Whom it may concern, Southeast General Contractors 10380 SW Village Center Dr. Unit 232 Port St Lucie, FL 34987 633 SE Hidden River Drive Port St Lucie, Florida 20080279 As requested, we tested the compacted fill for the House Pad. Mailing PO Box 78-1377 Sebastian, FL. 32978 Phone: 772-589-0712 C.A.# 5693 KSMengineering.net KSM JOB # : 211934-2d/SS/bm To determine if the fill was properly compacted on the pad to a depth of 3 feet, we performed nuclear density tests on the top two feet. To estimate the soil density below a depth of 2 feet we used a Static Cone Penetrometer. During the tests, a shaft with a conical point is pushed through soil and the soil resistance measured on a calibrated gauge. After the soil resistance is measured, the hole is advanced with a hand -auger in 1-foot increments to permit a continuation of measurement of density versus depth. Test Results: Nuclear density tests performed on the top 2 feet indicates the compaction exceeds the project specifications of 95% (ASTM 1557). Static Cone Penetrometer readings indicate the compacted backfill below 2 feet are generally well compacted to a depth of 3 feet. Based on the nuclear density tests and Static Cone Penetrometer readings, it appears the fill on the house pad was properly compacted. Should you have any questions, please feel free to contact our office. Respectfully, Digitally signed by This item has been electronically signed and sealed by Bryan E. Dahike, PE R Li,, 814'9 g rya n E Da h I ke on the date stated directly to the right using a digital signature. Date: Printed copies of this documents are not nsidered signed and sealed and the ,,gnat..m tbe�er,flednnanyeieetrnnle '.Pies. 2021.06.07 12:47:20 —04'00' Bryan E. Dahlke, P.E. V.P. of Engineering PE # 81439 06/07/21 Email: frank@southeastcontracting.com Test report shall not be reproduced, except in full, without the written approval of KSM Engineering & Testing Geotechnical Engineering - Construction Materials Testing - Special Inspections - Civil and Structural Consulting Proudly Serving Florida since 1990 Certified Women Owned Business - WBE Headquarters 1W C IL � ENGINEERING Mailing 11345 U.S. Highway 1 PO Box 78-1377 Sebastian, FL. 32958 1 %% AND TESTING Sebastian, FL. 32978 Orlando Phone: 772-589-0712 723 Progress Way SOIL COMPACTION REPORT C.A.# 5693 Sanford, FL. 32771 ASTM D 1557 and ASTM D 6938 KSMengineering.net DATE TESTED: PERMIT #: CONTRACTOR: JOB LOCATION: June 4, 2021 20080279 Southeast General Contractors 633 SE Hidden River Drive Port St Lucie, Florida KSM JOB #: 211934-2d/SS/bm NUC # 528 Nuc Model: MC-IDR-P Nuc Serial #: MD049528 ITEM TESTED: House Pad TEST LOCATION PEN DRY MAX. DRY PERCENT DEPTH OF SAMPLE READ DENSITY PROCTOR VALUE (P.C.F) COMPACTION 1 S.W. 0" - 12" 50+ 113.7 114.8 99.0% 2 Center 114.1 99.4% 3 N.E. 112.8 98.3% 4 N.W. 12" - 24" 50+ 113.1 98.5% 5 S.E. 113.6 99.0% Soil Description: 116.0 I I I I I I 1 Gray Shelled Sand W E 115.0 J_.. �.._.�_.. .._-._..� �.._.�_.._ In Place Moisture: I I I I I I I I 11.3% H 114.0 Proctor Optimum Moisture: T 113.0 t— J.._.I_..1. I._..L..J.. I_.._ 0 12.0 % p I I I I I I Proctor Max. Dry Density: P.C.F. 112.0- 114.8 C I I I I I I I @ Test Locations the Density & F 111.0 I— Penetrometer readings indicate the I I I I I Degree of Compaction Meets 110.0 • Minimum Requirement D I I T I r for Unstaked Foundation R 109.0..�.._.i_..t.._�._..r..�.._.�_..� I I I I I I I Respectfully Submitted: Y 7 8 9 10 11 12 13 14 15 Moisture - % of Dry Weight Disclaimer: Contractor is responsible to maintain the tested area in the condition that KSM completed the indicated passed compaction test. KSM is not responsible if the tested area has been altered from the approved inspected condition. Bryan E. Dahlke, P.E. V.P. of Engineering PE # 81439 6/7/2021 Email: frank@southeastcontracting.com Test report shall not be reproduced, except in full, without the written approval of KSM Engineering & Testing Geotechnical Engineering - Construction Materials Testing - Special Inspections - Civil and Structural Consulting Proudly Serving Florida since 1990 Certified Women Owned Business - WBE