Loading...
HomeMy WebLinkAboutEnergy CodeFORM R405-2020 FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION Florida Department of Business and Professional Regulation -Residential Performance Method Project Name: Lot 9 Block 1 Waterstone 1820 BGR Builder Name: ADAMS HOMES Street: 5424 Lugo Street Permit Office: City, State, Zip: Fort Pierce , FL, 34951 Permit Number: Owner: Jurisdiction: 661000 Design Location: FL, ST_LUCIE_CO_INTL County: St. Lucie (Florida Climate Zone 2 ) 1. New construction or existing New (From Plans) 10. Wall TypeV120.0 sqft.) Insulation Area 2. Single family or multiple family Detached a. Concrete Block - Int Insul, Exterior R=4.1 1850.00 ft2 3. Number of units, if multiple family 1 b. Frame - Wood, Adjacent R=13.0 270.00 ft2 4. Number of Bedrooms 4 c. N/A d. N/A R= ft2 5. Is this a worst case? No 11. Ceiling Types (1900.0 sqft.) R= ft2 Insulation Area 6. Conditioned floor area above grade (ft2) 1820 a. Under Attic (Vented) b. Knee Wall (Vented) R=30.0 1820.00 ft2 R=19.0 Conditioned floor area below grade (ft2) 0 c. N/A 80.00 ft2 R= ft2 7: Windows(239.3 sqft.) Description Area 12. Ducts R ft2 a. U-Factor: Dbl, U=0.33 136.36 ft2 a. Sup: Attic, Ret: Main, AH: Main 6 364• SHGC: SHGC=0.23 b. U-Factor: Dbl, U=0.33 32.38 ft2 13. Cooling systems kBtu/hr Efficiency SHGC: SHGC=0.21 a. Central Unit 35.0 SEER:16.00 c. U-Factor: Dbl, U=0.30 32.38 ft2 SHGC: SHGC=0.23 Area Weighted Average Overhang Depth: 4.251 ft. 14. Heating systems kBtu/hr Efficiency Area Weighted Average SHGC: 0.269 a. Electric Heat Pump 34.6 HSPF:8.50 8. Skylights Area c. U-Factor:(AVG) N/A ft2 15. Hot water systems SHGC(AVG): N/A 9. Floor Types (1820.0 sqft.) Insulation Area a. Electric Ca 40 p: gallons a. Slab -On -Grade Edge Insulation R=0.0 1820.00 ft2 b. Conservation features EF: 0.940 b. N/A R= ft2 None c. N/A R= ft2 16. Credits Pstat Glass/Floor Area: 0.131 Total Proposed Modified Loads: 61.38 PASS Total Baseline Loads: 64.83 I hereby certify that the plans a cations covered Revie -of the plans and Y= ap this calculation are in compli c e Flori rgy specifications covered by this Q Code. calculation indicates compliance "titip PREPARED BY: with the Florida Energy Code. Before . r construction is completed r DATE: n2-oR_7o21 Winn Kann any this building will be inspected for compliance with Section 553.908 I hereby certify that this building, as designed, is in compliance Florida Statutes. , 6 with the Florida Energy Code. l OER/AGE c BUILDING OFFICIAL: .DATE: DATE: - Compliance requires certification by the air handler unit manufacturer that the air handler enclosure qualifies as certified factory -sealed in accordance with R403.3.2.1. - Compliance requires an Air Barrier and Insulation Inspection Checklist in accordance with R402.4.1.1 and this project requires an envelope leakage test report with envelope leakage no greater than 7.00 ACH50 (R402.4.1.2). 3/8/2021 3:33 PM EnergyGauge® USA 7.0.00 - FlaRes202O FBC 7th Edition (2020) Compliant Software Page 1 of 4 FORM R405-2020 INPUT SUMMARY CHECKLIST REPORT PROJECT Title: Lot 9 Block 1 Waterstone 182 Bedrooms: 4 Address Type: Lot Information Building Type: User Conditioned Area: 1820 Lot # 9-1 Owner Name: Total Stories: 1 Block/Subdivision: Waterstone # of Units: 1 Worst Case: No PlatBook: Builder Name: ADAMS HOMES Rotate Angle: 0 Street: 5424 Lugo Street Permit Office: Cross Ventilation: No County: St. Lucie Jurisdiction: 661000 Whole House Fan: No City, State, Zip: Fort Pierce Family Type: Detached , New/Existing: New (From Plans) FL , 34951 Comment: CLIMATE / Design Temp Int Design Temp Heating Design Daily Temp V Design Location TMY Site 97.5 % 2.5 % Winter Summer Degree Days Moisture Range FL, ST_LUCIE_CO_INTL FL_VERO_BEACH_MUNI 39 90 70 75 299 58 Medium BLOCKS Number Name Area Volume 1 Block1 1820 18200 SPACES Number Name Area Volume Kitchen Occupants Bedrooms InfilID Finished Cooled Heated 1 Main 1820 18200 Yes 5 4 1 Yes Yes Yes FLOORS # Floor Type Space Perimeter R-Value Area Tile Wood Carpet 1 Slab -On -Grade Edge Insulatio Main 33 ft 0 1820 ft2 _--- 0.42 0 0.58 ROOF / Roof Gable Roof Rad Solar SA Emitt Emitt Deck Pitch V # Type Materials Area Area Color Barr Absor. Tested Tested Insul. (deg) 1 Gable or Shed Composition shingles 2035 ft2 456 ft2 Medium N 0.85 N 0.85 No 0 26.57 ATTIC / V # Type Ventilation Vent Ratio (1 in) Area RBS IRCC 1 Full attic Vented 300 1820 ft2 N N CEILING # Ceiling Type Space R-Value Ins Type Area Framing Frac Truss Type T 1 Under Attic (Vented) Main 30 Blown 1820 ft2 0.11 Wood 2 Knee Wall (Vented) Main 19 Batt 80 W 0.11 Wood 3/8/2021 3:33 PM EnergyGauge® USA 7.0.00 - FlaRes202O FBC 7th Edition (2020) Compliant Software Page 2 of 4 FORM R405-2020 INPUT SUMMARY CHECKLIST REPORT WALLS Adjacent Cavit Width H ' ht 0 Wall T�jpp Space y - e1g Sheathing Framing Solar Below 1 SW Exterior Concrete Block - Int Insul Main 4.1 59 0 10 0 590.0 ft2 0 0 0.6 o 0 2 NW Exterior Concrete Block - Int Insul Main 4.1 20 0 10 0 200.0 ft2 0 0 0.6 0 3 NE Exterior Concrete Block - Int Insul Main 4.1 66 0 10 0 660.0 ft2 0 0 0.6 0 4 SE Exterior Concrete Block - Int Insul Main 4.1 40 0 10 0 400.0 ft2 0 0.6 0 5 - Garage Frame - Wood Main 13 27 0 10 0 270 0 ft2 0 0 23 0 01 DOORS # Ornt Door Type Space Storms U-Value Width Height Area Ft In Ft In 1 NW Insulated Main None .25 3 6 8 20 ft2 r' 2 - Wood Main None .25 2 8 6 8 17.8 ft2 WINDOWS " Orientation shown is the entered, Proposed orientation. / Wall Overhang V # Ornt ID Frame Panes NFRC U-Factor SHGC Imp Area Depth Separation Int Shade Screening 1 SW 1 Vinyl Low-E Double . Yes 0.33 0.23 N 6.9 ft2 1 ft 4 in 0 ft 10 in None Exterior 5 2 SW 1 Vinyl Low-E Double Yes 0.33 0.23 N 48.6 ft2 1 ft 4 in 0 ft 10 in None Exterior 5 3 NW 2 Vinyl Low-E Double Yes 0.33 0.31 N 7.1 ft2 9 ft 4 in 0 ft 0 in None None 4 NW 2 Vinyl Low-E Double Yes 0.33 0.21 N 16.2 ft2 1 ft 4 in 1 ft 0 in None None 5 NW 2 Vinyl Low-E Double Yes 0.33 0.21 N 16.2 ft2 1 ft 4 in 1 ft 0 in None Exterior 5 6 NW 2 Vinyl Low-E Double Yes 0.33 0.31 N 13.3 ft2 9 ft 4 in 1 ft 6 in None None 7 NE 3 Vinyl Low-E Double Yes 0.33 0.23 N 48.6 ft2 1 ft 4 in 0 ft 10 in None Exterior 5 8 SE 4 Vinyl Low-E Double Yes 0.55 0.7 N 17.8 ft2 12 ft 0 in 0 ft 6 in None None 9 SE 4 Vinyl Low-E Double Yes 0.3 0.23 N 32.4 ft2 1 ft 4 in 0 ft 10 in None Exterior 5 10 SE 4 Vinyl Low-E Double Yes 0.33 0.23 N 32.4 ft2 12 ft 0 in 0 ft 6 in None Exterior 5 GARAGE # Floor Area Ceiling Area Exposed Wall Perimeter Avg. Wall Height Exposed Wall Insulation 1 596 ft2 596 ft2 64 ft 8 ft 1 INFILTRATION # Scope Method SLA CFM 50 ELA EgLA ACH ACH 50 1 Wholehouse Proposed ACH(50) .000444 2123.3 116.49 218.7 .1381 7 HEATING SYSTEM # System Type Subtype Speed Efficiency Capacity Block Ducts 1 Electric Heat Pump/ Split Singl HSPF:8.5 34.6 kBtu/hr 1 sys#1 3/8/2021 3:33 PM EnergyGauge® USA 7.0.00 - FlaRes202O FBC 7th Edition (2020) Compliant Software Page 3 of 4 FORM R405-2020 INP11T SI IMMARV r14=r►Lf1 icr oConor - - - ---- - - - N % l COOLING SYSTEM # System Type Subtype Subtype Efficiency Capacity Air Flow SHR Block Ducts 1 Central Unit/ Split Singl SEER: 16 35 kBtu/hr cfm 0.75 1 sys#1 HOT WATER SYSTEM # System Type SubType Location EF Cap Use SetPnt Conservation 1 Electric None Garage 0.94 40 gal 62.3 gal 120 deg None SOLAR HOT WATER SYSTEM FSEC Collector Storage Cert # Company Name System Model # Collector Model # Area Volume FEF None None ft2 DUCTS / ---- Supply ---- ---- Return ---- Air CFM 25 CFM25 HVAC # Location R-Value Area Location Area Leakage Type Handler TOT OUT QN RLF Heat Cool 1 Attic 6 364 ftz Main 91 ft' Default Leakage Main (Default) (Default) 1 1 TEMPERATURES Programable Thermostat: Y Ceiling Fans: Cooling Jan Feb Heating Jan Feb Venting Mar Mar HX A r APr Jul May Jun Jul IMa X Jun ri AuSeP ri Aug Se ri Oct Oct Nov Nov HX Dec Dec H Jan Feb Mar [X] Apr [ May [ Jun Jul Aug Se [X] Oct Nov Dec Thermostat Schedule: HERS 2006 Reference Hours Schedule Type 1 2 3 4 5 6 7 -8 9 10 11 12 Cooling (WD) AM PM 78 80 78 78 80 78 78 78 78 78 78 80 80 80 80 78 78 78 78 78 78 78 78 78 Cooling (WEH) AM PM 78 78 78 78 78 78 78 78 78 78 78 78 78 78 78 78 78 78 78 78 78 78 78 78 Heating (WD) AM PM 66 68 66 66 68 68 66 66 68 68 68 68 68 68 68 68 68 68 68 68 68 68 66 66 Heating (WEH) AM PM 66 68 66 66 68 68 66 66 68 68 68 68 68 68 68 68 68 68 68 68 68 68 66 66 MASS Mass Type Area Thickness Furniture Fraction Space Default 8 Ibs/s .ft. 0 ftz Oft 0.3 Main 3/8/2021 3:33 PM EnergyGauge® USA 7.0.00 - FlaRes202O FBC 7th Edition (2020) Compliant Software Page 4 of 4 IL FORM R405-2020 ENERGY PERFORMANCE LEVEL (EPL) DISPLAY CARD ESTIMATED ENERGY PERFORMANCE INDEX* = 95 The lower the EnergyPerformance Index, the more efficient the home. 5424 Lugo Street, Fort Pierce, FL, 34951 1. New construction or existing New (From Plans) 10. Wall Type and Insulation Insulation Area 2. Single family or multiple family Detached a. Concrete Block - Int Insul, Exterior R=4.1 1850.00 ftZ 3. Number of units, if multiple family 1 b. Frame - Wood, Adjacent R=13.0 270.00 ft2 c. N/A R= ftZ " 4. Number of Bedrooms 4 d. N/A R= ftZ 5. Is this a worst case? No 11. Ceiling Type and insulation level Insulation Area a. Under Attic (Vented) R=30.0 1820.00 ftz 6. Conditioned floor area (ftZ) 1820 b. Knee Wall (Vented) R=19.0 80.00 ftz 7. Windows" Description Area c. N/A R= ftZ a. U-Factor: Dbl, U=0.33 136.36 ftZ 12. Ducts, location & insulation level R ftZ SHGC: SHGC=0.23 a. Sup: Attic, Ret: Main, AH: Main 6 364 b.. U-Factor: Dbl, U=0.33 32.38 ftZ SHGC: SHGC=0.21 13. Cooling systems kBtu/hr Efficiency c. U-Factor: Dbl, U=0.30 32.38 ftZ a. Central Unit 35.0 SEER:16.00 SHGC: SHGC=0.23 d. U-Factor: other (see details) 38.19 ftZ SHGC: other (see details) 14. Heating systems kBtu/hr Efficiency Area Weighted Average Overhang Depth: 4.251 ft. a. Electric Heat Pump 34.6 HSPF:8.50 Area Weighted Average SHGC: 0.269 8. Skylights Description Area 15. Hot water systems a. U-Factor(AVG): N/A ftZ a. Electric Cap: 40 gallons SHGC(AVG): N/A EF:0.94 9. Floor Types Insulation Area b. Conservation features a. Slab -On -Grade Edge Insulation R=0.0 1820.00 ftZ None b. N/A R= ftZ Credits (Performance method) Pstat c. N/A R= ftZ I certify that this home has complied with the Florida Energy Efficiency Code for Building Construction through the above energy saving features which will be installed (or exceeded) in this home before final inspection. Otherwise, a new EPL Display Card will be completed based on installed Code compliant features. Builder Signature 1 �� Date: Address of New Home: City/FL Zip: *Note: This is not a Building Energy Rating. If your Index is below 70, your home may qualify for energy efficient mortgage (EEM) incentives if you obtain a Florida Energy Rating. For information about the Florida Building Code, Energy Conservation, contact the Florida Building Commission's support staff. **Label required by Section R303,1.3 of the Florida Building Code, Energy Conservation, if not DEFAULT. 3/8/2021 3:34 PM EnergyGauge® USA 7.0.00 - FlaRes2020 FBC 7th Edition (2020) Compliant Software Page 1 of 1