HomeMy WebLinkAbout20-249A Ocean Harbor N BLDG A - Rep 2 - 06.01.21M L Engineering Inc. Consulting Engineers Threshold Inspector 2030 37th Avenue Vero Beach, Florida 32960 Phone: (772) 569-1257 Fax: (772) 569-4041 www.mlengineeringinc.com Project No. 20-249A Report No. 2 Project Manager: Building Official: Contractor: File Mr. Gene Ross – Elliott Merrill Community Mgmt. SLC Bldg. Dept. Mr. Robert Stark – Structure-Con Mr. Khris McConnell – Structure Con Page 1 of 2 THRESHOLD INSPECTION REPORT OCEAN HARBOR NORTH CONDOMINIUMS – BLDG. A CONCRETE REPAIRS 5151 N. HWY. A1A, FT. PIERCE, FL 34949 SLC BUILDING PERMIT NUMBER: 2103-0590 PROJECT NAME: Ocean Harbor N. Condos – Bldg. A DATE: June 1, 2021 CLIENT: Elliott Merrill Community Management LOCATION: Ft. Pierce, FL CONTRACTOR: Structure-Con PROJECT MGR: Mr. Khris McConnell INSPECTED BY: Todd Rhoten WEATHER: Sunny WORK INSPECTED: Units 215/315, 315/415, 415/515, 515/615 & 811 OBSERVATIONS: Units 215/315, 315/415 & 415/515 • All repaired areas have been poured with the approved repair mortar. • Preparation for new waterproofing at repaired areas has begun. • Stucco at ceiling applied at all full depth repairs. Unit 515/615 • Tile removed at the spalled area. • Loose concrete has been chipped at the east facing sliding glass door. • Corrosion in the reinforcing bars does not extend into the unit. • Spalling area is partial depth and does not require full depth repair. Unit 811 • Roof slab edge has been repaired in the 2-foot sections as recommended. • The extent of corrosion was limited to the north facing edge only. • Stucco has been replaced at the repaired areas. RECOMMENDATIONS: Unit 515/615 • All bars shall be power tool cleaned and painted with a corrosion inhibitor. • Form and pour repair areas with a high strength repair mortar and provide proper clearance for all reinforcing bars. All work to date is in compliance with recommendations as indicated in the permitted documents. ______________________________ _________________________________ Michael Lue, P.E. Todd Rhoten, Inspector M L Engineering Inc. Consulting Engineers Threshold Inspector 2030 37th Avenue Vero Beach, Florida 32960 Phone: (772) 569-1257 Fax: (772) 569-4041 www.mlengineeringinc.com Project No. 20-249A Report No. 2 Project Manager: Building Official: Contractor: File Mr. Gene Ross – Elliott Merrill Community Mgmt. SLC Bldg. Dept. Mr. Robert Stark – Structure-Con Mr. Khris McConnell – Structure Con Page 2 of 2 Pic 1 Unit 315 Stucco repair at ceiling of full depth repair. Pic 2 Unit 415 Surface repair ground flush with surrounding areas and is ready for new waterproofing. Pic 3 Unit 811 Ceiling spall repairs in progress.