Loading...
HomeMy WebLinkAbout14Typical vertical #5 Rebar Spacing 3x Place as shown Window & Door Section Align furring straps to the closest corner & build in to center of each wall for an even 6" spacing for as much of the wall as possable Ir Screws [led in Bu( 'c concretc 0 min sizc anizcd y Coated acing -45.00"; 6.50" Rise: 12" Run Stager 2" from center �uck Top &Sides detail P.T. 2x 12 trimmed to 11 " wide Buck Bottom detail P.T. 2x4 inside & outside Gap inbetween for concrete pour and vibe access 2x 95 Bar Vertical Each side, Lintel / Opening Detail O co Garage Man Door (D Stairway Detail Peel and Stick Flashing & NN ater Barrier on External Cupola walls & window openings ICF =il'.T. Buck Fluid Applied n Monolithic Flashing On all ICF door & window openings Window & Door Stirrup sizes & spacing overhead lintels FLOOR 1 � FLOOR 2 (Bottom (Bottom ID Steel) (E) Steel) (E) A *NR *NR 1- #4 *NR B 1- #5 *FL 1- #4 *NR C *NR *NR *NR *NR D 1- #6 *FL *NR *NR E 1- #6 *FL 1- #5 12 F *NR *NR 1- #4 *NR G 1- #4 *FL 1- #4 NR H 1- #4 *NR 1- #4 *NR I 1- #4 *NR 1- #4 *NR J *NR *NR 1- #4 *NR K 1- #4 *FL *NR NR L *NR *NR 1- #4 *NR M 1- #5 *FL *NR *NR N 1- #6 *FL *NR *NR Q--- -- ----- -- --- --- -- ----- -- --- P--- Q -- ----- -- --- --- -- ----- -- --- R *NR *NR 1- #4 *NR S 1- #5 *FL *NR *NR T 1- #5 *FL *NR *NR U--- -- ----- -- --- --- -- ----- -- --- V--- -- ----- -- --- --- -- ----- -- --- W 2- #6 *FL *NR *NR 1- #5 *FL *NR *NR *NR *NR 1- #5 18 1- #6 *FL 1- #5 12 1- #4 *FL *NR *NR LINTEL DETAIL Required Lintel and opening reinforcement Top Rebar 1 - #5 1 ypical or S Stirrups Bottom rebar Single or Double bar 1 M,iy 4" Vin Standard Stirrup #3 Stec] 314" min �q s �y "S" Type Stirrup #3 Sted 4" min . fJ scale none A. 24" Minimum distance. May wrap 90' around corners. B. Bucking System C. Vertical reinforcement. 2) #5 vertical rebars each side of opening. D. Locate first stirrup at 1/2 spacing(s) from the face of opening. Remaining Stirrups at "S" to stirrup end distance. E. Stirrup end distance. Specified in Lintel Tables. F. 900 rebar around all openings in addition to required Lintel and wall reinforcement. G. 2- 45 additional rebar around all openings, in addition to required Lintel and wall reinforcement. H. If lintel table has bottom reinforcing of at least 2 45 rebar, add 1- #5 rebar at top of opening. All shear reinforcement (#3 rebar) is at 6" spacing up to end distance at each end of lintel beam. *FL = Stirrups are required the Full Length of the Lintel Beam *NR — Not Required Note: required wall reinforcement, ICF blocks & stem wall (if applicable) not shown for clarity. 1 /2" Plywo with 4-8D 1 top & botto ��_eFIT F. �4Nrrrrr This item has been electronically signed and sealed by Robert F. ��r•''EN r�rp C,f :r0 a Oleck, Ph.D.,PE using a Digital Signature and date. Printed t " copies of this document are not RtoP. - i @ considered signed and sealed and the signature must be ' S ••..,„,,. • 3� �� verified on any electronic copies. r��S,ONA„`���� ZETA-12 )r overhang Digitally signed by Robert F Oleck Date: 2021.05.21 10:21:24 -04'00' EPS foam, attach continous ICF wall with 1/4" X 4 " 8" O.C. Stagger top to bottom Front 4' Overhang & Corbel Section External Staircase detail (North)(D CMU columns mid spaced inbetween windows "A" & "F 56.00"1 [3.51 I ¢�z=4�n UNr`µ Fr"�Q G 5 u p aai A.� FW1��7+v PH�mY 0 Who GFE�¢�k�a Q F L1 W CP,=aIF" 0000 N N N N N r• ,-I Qnnoon c��ao t- oo o� M A 0 � •POO y IT! W •� � o .� rN- � M �!3 e--I N 4-� C/� Page: 14 Scale: P 112" 0 :24)