Loading...
HomeMy WebLinkAbout3Notes: All dimensions are to ICF & or wall framing {x.xx} =Vertical distance from Datum 1 MCxx = Square CMU Masonary Column, Size IC (Insulated Concrete Form), 6" Core, 2.5" EPS foam, 11.00" Total Width Concrete: per structural notes sheet 2 All lintels in Exterior ICF walls shall be 6" thick by 16" deep with 1-#5 top and 1-#5 bottom unless noted otherwise on the plan, refer to Typical Lintel Detail an Table on Sheet 14 4- #5 Vert & #3 Hoop Ties at 12" o.c. T. all 12"x12" & 16"x16" CMU Colum ns 2" r 20 gage composite metal deck with l,C IG 3" ornormal tireighI concrete & 6x6x10/10 MC16 or 6x6v F1`1.4x1A. Welded wire mesh at middleofconcrete -Typ. 8" min foam removed from outter wall in this 14'-0" rea for precast lintel beam loading o � v� 14'-8" 4'-0" L Precast Lintel 13'-4" -10.50"} —�° Precast Lintel {-10.50" 8" -4.00"} :J r NIC16 M 11('16 ` HVAC Pad co 12'-10" Water equipment �' 4, j o B� � �o N 13'-8 112" r 8" min foam removed from outter wall in this Card Room 4 `� area for precast lintel beam loading Office 5'-1 114" Fr ich 8" min foam removed Elevator from inner wall in this Rough in onlN �. D N ! in area for floor beam load Removable �C Floor installed n 6 6 112" Bathroom 3 It l' Elevator 4'-2 1 /2" L1' co Mechanical 2" r 20 gage composite metal deck with 35'-4" 3" or normal Si eight concrete & 6x6x10110 MC16 or 6x6xF1`1.4xIA. Welded wire mesh at middle of concrete - Typ. 0o v V C_ 0 12'-8" 4'-8" 13'-4" 13'41 Precast Lintel Precast Lintel Precast Lintel c Precast Lintel 1-4A0"; {-4.00"{ 1-10.50"1.2 MCI() MCI() NIC16 -4" NIC16 Lanai O L O _o L- a 8 }'r uh Z 11"' I �0 i { 3 - ,(12"} 3068 t-9.62"}s' 8° ATM F4'-0" - 12'-10" -2.37"{ {-7•37"), 8" min foam removed M-4 -7.31" a 1 { from outter wall in this area for precast lintel J0 } beam loading MC16 {-8.75" t . 1„) II Ij II }� mrl� C 1 4-5.50" } HVAC #2 20'-0" am L 11 1 {- 0011 4- #5 Vert & #3 hoop Ties at 12" o.c. I j N'IC 16 U1I I{-1.50"} 308pR (308OR Tip. all 12"x]2" CN1U Columns 26'-8" II I, AR2 68E II Ij III Mudroom , c Kill �°°S {0.00" Datuml}11 -0 1i2"I M N II II Garage 2080E Floor Slope 1/8" : V I I I j l� 4- 45 Vert & 43 H op Ties at 12" o.c. 8 1I TNp. all 12"x12" MU Columns I j Fire Escape 'Window ti Bedroom 4 N 0 co 14'-0" 3080L l Parallam 5-1/4" x 5-114" Post / Column - See Flour 000000 Framing Sheet _ Floor Girder FG04 above 4'-a" Stairs open to above 0 2'-8"A' 2'-8" + 2'48" 18'-8" II H II Ij 1C1 1C1 II j NIC16 Bar 14 -0" 3'-8 1I2" H 11 1C1 II Ij q II II C; _ I 1z o II II ti II II ' 8" min foam removed from outter wall in this 5'-7" - area for precast lime 30 OR {-5.50"} beam loading MCI) {-1.50"; 2668R t-7.12" 3' 4" i -7.12 1 Lowet Entry Safe Room N Storage 5'-4" HVAC Pad v T-8„ u 8' 9" 7' 2 6'-4" 1 U-7" 8" min foam removed from outter 13-4" wall in this area for precast lintel "' 4'-0" 4'-4" Precast Lintel beam loading N'IC8\16 SX16 Y C8X16 \I C 16 N9 _'16 12'-8" 18'-8" 14'-0" N ZD YC d a+ = C. O a Porte-Cochere u Q- O O AX:16 11'-4" 7'-8" 14 -0" — Precast lintel x2 15'-4" — 50'-0 it0ttitliiisy+°4" F•04 This item has been electronically p�� ®�? r�°, signed and sealed by Robert F. Oleck, Ph.D.,PE using a Digital Signature and date. Printed y� t copies of this document are not considered signed and sealed • ." �W : ••..,,,�..•• and the signature must be ° tt*s �' �ar� NA verified on any electronic copies. ;tes��® Digitally signed by Robert F Oleck Date: 2021005021 10:03:39 -04'00 1 st floor under air 1,815.9 sqft Bedroom 4 207.5 Office 171.7 1st floor bathroom 3 55.1 Elevator mechanical room 25.9 Elevator 26.9 1 st floor living 682.4 stair case base 281.8 lower entry 103.1 Mud Room 70.0 Card room 144.4 Safe room 47.2 1st floor non AC 1,020.9 sqft Garage 988.7 Storage 32.3 4 Structural Engineer Z O � Can .. • • 5 con Page: 3 Scale: P 114" { 1:48)