HomeMy WebLinkAboutEnergy CodeFORM R405-2020
FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION
Florida Department of Business and Professional
Regulation - Residential Performance Method
Project Name: Lot 121 Block 5 Waterstone 1780 BGL
Builder Name: ADAMS HOMES
Street: 5346 San Benedetto Place
Permit Office:
City, State, Zip: Fort Pierce , FL, 34951
Permit Number:
Owner:
Jurisdiction: 661000
. Design Location: FL, ST_LUCIE_CO_INTL
County: St. Lucie (Florida Climate Zone 2 )
1. New construction or existing New (From Plans)
10. Wall Typet1513.4 sqft.)
Insulation Area
2. Single family or multiple family Detached
'
a. Concrete Block - Int Insul, Exterior
R=4.1 1245.40 ftz
3. Number of units, if multiple family 1
b. Frame - Wood, Adjacent
R=13.0 268.00 ftz
c. N/A
R= ft2
4. Number of Bedrooms 3
d. N/A
R= ft2
5. Is this a worst case? No
11. Ceiling Types (1900.0 sgft.)
Insulation Area
a. Under Attic (Vented)
R=30.0 1780.00 ft2
6. Conditioned floor area above grade (ft2) 1780
b. Knee Wall (Vented)
R=19.0 120.00 ft2
Conditioned floor area below grade (ft2) 0
c. N/A
R= ft2
7. Windows(177.0 sqft.) Description Area
12. Ducts
R ft2
a. U-Factor: Dbl, U=0.33 113.31 ft2
a. Sup: Attic, Ret: Main, AH: Main
6 356
SHGC: SHGC=0.23
b. U-Factor: Dbl, U=0.33 45.94 ft2
13. Cooling systems
kBtu/hr Efficiency
SHGC: SHGC=0.21
a. Central Unit
28.4 SEER:15.00
c. U-Factor: Dbl, U=0.55 17.78 ft2
SHGC: SHGC=0.70
Area Weighted Average Overhang Depth: 2.639 ft.
14. Heating systems
kBtu/hr Efficiency
Area Weighted Average SHGC: 0.272
a. Electric Heat Pump
28.2 HSPF:8.50
8. Skylights Area
c. U-Factor:(AVG) N/A ft2
15. Hot water systems
SHGC(AVG): N/A
9. Floor Types (1780.0 sqft.) Insulation Area
a. Electric
Cap: 40 gallons
a. Slab -On -Grade Edge Insulation R=0.0 1780.00 ft2
b. Conservation features
EF: 0.940
b. N/A R= ft2
None
c. N/A R= ft2
16. Credits
Pstat
Glass/Floor Area: 0.099 Total Proposed Modified Loads: 52.65
PASS
Total Baseline Loads: 52.92
I hereby certify that the plans a' cations covered
Revie of the plans and
O Z14E §Z`
this calculation are in compli c i ergy
specifications covered by this
� __ p
Code.
calculation indicates compliance
with the Florida Energy Code.
:O
PREPARED BY:
Before construction is completed
r a.
DATE: 04-28_2021 Winn Kanmany
this building will be inspected fortv
compliance with Section 553.908
I hereby certify that this building, as designed, is in compliance
with the Florida Enema o' e.'GpDv
Florida Statutes.
:.
OWNER/AGEN- . `
BUILDING OFFICIAL:
DATE:
DATE:
- Compliance requires certification by the air handler unit manufacturer that the air handler enclosure
qualifies as
certified factory -sealed in accordance with R403.3.2.1.
�. - Compliance requires an Air Barrier and Insulation Inspection
Checklist in accordance with R402.4.1.1
and this project requires an
envelope leakage test report with envelope leakage no greater
than 6.50 ACH50 (R402.4.1.2).
- Compliance with a proposed duct leakage Qn requires a Duct Leakage Test Report confirming duct
leakage to outdoors,
tested in accordance with ANSI/RESNET/ICC 380, is not greater than 0.055 Qn for whole house.
4/26/2021 8:53 AM 7.0.00 - FlaRes202O FBC 7th Edition (2020) Compliant Software Page 1 of 4
FORM R405-2020
INPUT SUMMARY CHECKLIST REPORT
PROJECT
Title:
Lot 121 Block 5 Waterstone 1 Bedrooms: 3
Address Type:
Street Address
Building Type:
User
Conditioned Area: 1780
Lot #
121-5
Owner Name:
Total Stories: 1
Block/Subdivision:
Waterstone
# of Units:
1
Worst Case: No
PlatBook:
Builder Name:
ADAMS HOMES
Rotate Angle: 0
Street:
5346 San Benedetto PI
Permit Office:
Cross Ventilation: No
County:
St. Lucie
Jurisdiction:
661000
Whole House Fan: No
City, State, Zip:
Fort Pierce
Family Type:
Detached
,
FL, 34951
New/Existing:
New (From Plans)
Comment:
CLIMATE
/
Design Temp
Int Design Temp Heating
Design Daily Temp
V Design Location
TMY Site 97.5 % 2.5 %
Winter Summer Degree Days Moisture Range
FL, ST_LUCIE_CO_INTL FL_VERO_BEACH _MUNI 39 90
70 75 299
58 Medium
BLOCKS
Number
Name
Area Volume
1
Block1
1780 15664
SPACES
Number
Name
Area Volume Kitchen Occupants
Bedrooms InfilID Finished Cooled Heated
1
Main
1780 15664 Yes 4
3 1 Yes
Yes Yes
FLOORS
#
Floor Type
Space Perimeter R-Value
Area
Tile Wood Carpet
1 Slab -On -Grade Edge Insulatio Main 155.7 ft 0
1780 ft2 ----
0.38 0 0.62
ROOF
/
Roof Gable Roof
Rad Solar SA Emitt
Emitt Deck Pitch
V #
Type
Materials Area Area Color
Barr Absor. Tested
Tested Insul. (deg)
1
Gable or Shed Composition shingles 1990 ft2 446 ft2 Medium
N 0.85 N 0.85
No 0 26.57
ATTIC
V #
Type
Ventilation Vent Ratio (1 in)
Area RBS IRCC
1
Full attic
Vented 300 1780 ft2 N N
CEILING
#
Ceiling Type
Space R-Value Ins Type Area Framing Frac Truss Type
1
Knee Wall (Vented)
Main 19 Batt
120 ft2 0.11
Wood
2
Under Attic (Vented)
Main 30 Blown
1780 ft2 0.11
Wood
4/26/2021 8:53 AM 7.0.00 - FlaRes2020 FBC 7th Edition (2020) Compliant Software Page 2 of 4
FORM R405-2020 IMPI IT CI IMMADV (%UCr f1 icT ocnnn-r
WALLS
Adjacent
F # C)rnt Tn Wall T�l '
Space
Cavity Width
-
Height
Sheathing Framing Solar Below
o
1 SE Exterior Concrete Block - Int Insul
Main
4.1 40 0
8 0
320.0 ft2
0
0 0.6
0
2 NE Exterior Concrete Block- Int Insul
Main
4.1 40 6
8 0
324.0 ft2
0
0 0.6
0
3 N Exterior Concrete Block - Int Insul
Main
4.1 3 0
9 6
28.5 ft2
0
0 0.6
0
4 NW Exterior Concrete Block - Int Insul
Main
4.1 11 10
9 6
112.4 ftZ
0
0 0.6
0
5 W Exterior Concrete Block - Int Insul
Main
4.1 3 0
9 6
28.5 ft2
0
0 0.6
0
6 SW Exterior Concrete Block - Int Insul
Main
4.1 54 0
8 0
432.0 ft2
0
0 0.6
0
7 Garage Frame - Wood
Main
13 33 6
8 0
268.0 ft2
0
0.23 0.01
0
DOORS
# Ornt Door Type Space
Storms
U-Value
Width
Height
Area
Ft In
Ft In
1 NW Insulated Main
None
.25
3
6 8
20 ft2
2 - Wood Main
None
.25
2
8
6 8
17.8 ft2
WINDOWS
Orientation shown is the entered, Proposed
orientation.
/ Wall
V
Overhang
# Ornt ID Frame Panes NFRC
U-Factor SHGC Imp
Area
Depth
Separation
Int Shade
Screening
1 SE 1 Metal Low-E Double
Yes
0.55 0.7 N
17.8 ft2
14 ft 4 in
0 ft 10 in
None
None
2 SE 1 Vinyl Low-E Double
Yes
0.33 0.23 N
32.4 ft2
1 ft 4 in
0 ft 10 in
Drapes/blinds
None
3 NE 2 Vinyl Low-E Double
Yes
0.33 0.23 N
32.4 ft2
1 ft 4 in
0 ft 10 in
Drapes/blinds
None
4 N 3 Vinyl Low-E Double
Yes
0.33 0.21 N
11.4 ft2
1 ft 4 in
0 ft 10 in
Drapes/blinds
None
5 NW 4 Vinyl Low-E Double
Yes
0.33 0.21 N
23.2 ft2
1 ft 4 in
0 ft 10 in
Drapes/blinds
None
6 W 5 Vinyl Low-E Double
Yes
0.33 0.21 N
11.4 ft2
1 ft 4 in
0 ft 10 in
Drapes/blinds
None
7 SW 6 Vinyl Low-E Double
Yes
0.33 0.23 N
48.6 ft2
1 ft 4 in
0 ft 10 in
Drapes/blinds
None
GARAGE
# Floor Area Ceiling Area
Exposed Wall Perimeter
Avg. Wall Height
Exposed Wall Insulation
1 391 ft2 391 ft2
64 ft
8 ft
1
INFILTRATION
# Scope Method SLA
CFM 50 ELA EgLA
ACH
ACH 50
1 Wholehouse Proposed ACH(50) .000363
1696.9 93.1 174.78
.1219
6.5
HEATING SYSTEM
# System Type Subtype
Speed Efficiency
Capacity
Block
Ducts
1 Electric Heat Pump/ Split
Singl HSPF:8.5
28.2 kBtu/hr
1
sys#1
4/26/2021 8:53 AM 7.0.00 - FlaRes2020 FBC 7th Edition (2020) Compliant Software Page 3 of 4
' - FORM
)5-2020
INPUT SUMMARY CHECKLIST REPORT
COOLING SYSTEM
#
System Type
Subtype Subtype Efficiency Capacity Air Flow
SHR Block Ducts
1
Central Unit/
Split Singl SEER: 15 28.4 kBtu/hr cfm
0.75 1 sys#1
HOT WATER SYSTEM
#
System Type
SubType Location EF Cap Use SetPnt
Conservation
1
Electric
None Garage 0.94 40 gal 62.3 gal 120 deg
None
SOLAR HOT WATER SYSTEM
FSEC
Collector
Storage
Cert #
Company Name System Model # Collector Model # Area
Volume FEF
None
None
ft2
DUCTS
/
---- Supply ----
---- Return ---
Air
CFM 25
CFM25
HVAC #
#
Location R-Value Area
Location
Area
Leakage Type
Handler
TOT
OUT
QN
RLF
Heat Cool
1
Attic
6 356 ft2
Main
89 ft2
Proposed Qn
Main
--- cfm
97.9 cfm 0.06 0.60
1 1
TEMPERATURES
Programable Thermostat: Y
Ceiling Fans:
Cooling
Heating
Venting
Jan
Jan
H
] Feb
f X] Feb
Mar
Mar
Apr
APr
May
May
X Jun
f Jun
ri
Jul
Jul
Au
AuSeP
IlAug
Se
ri
Oct
Oct
Nov
Nov
HX
Dec
Dec
Jan
[ ]Feb
X Mar
[X]
A r
[
Ma
[ Jun
Jul
Se
[X]
Oct
Nov
ri Dec
Thermostat Schedule:
HERS 2006 Reference
Hours
Schedule Type
1
2
3
4
5
6
7
8
9
10
11
12
Cooling (WD)
AM
PM
78
80
78
80
78
78
78
78
78
78
78
80
80
80
80
78
78
78
78
78
78
78
78
78
Cooling (WEH)
AM
PM
78
78
78
78
78
78
78
78
78
78
78
78
78
78
78
78
78
78
78
78
78
78
78
78
Heating (WD)
AM
PM
66
68
66
68
66
68
66
66
68
68
68
68
68
68
68
68
68
68
68
68
68
68
66
66
Heating (WEH)
AM
PM
66
68
66
68
66
68
66
66
68
68
68
68
68
68
68
68
68
68
68
68
68
68
66
66
MASS
Mass Type
Area
Thickness
Furniture Fraction
Snare
4/26/2021 8:53 AM 7.0.00 - FlaRes202O FBC 7th Edition (2020) Compliant Software Page 4 of 4
FORM R405-2020
ENERGY PERFORMANCE LEVEL (EPL) DISPLAY CARD
ESTIMATED ENERGY PERFORMANCE INDEX* = 99
The lower the EnergyPerformance Index, the more efficient the home.
5346 San Benedetto Place, Fort Pierce, FL, 34951
1. New construction or existing
New (From Plans)
10. Wall Type and Insulation
Insulation
Area
► 2. Single family or multiple family
Detached
a. Concrete Block - Int Insul, Exterior
R=4.1
1245.40 W
b. Frame - Wood, Adjacent
R=13.0
268.00 ft2
3. Number of units, if multiple family
1
c. N/A
R=
ft2
4. Number of Bedrooms
3
d. N/A
R=
ft2
5. Is this a worst case?
No
11. Ceiling Type and insulation level
Insulation
Area
a. Under Attic (Vented)
R=30.0
1780.00 ft2
6. Conditioned floor area (ft2)
1780
b. Knee Wall (Vented)
R=19.0
120.00 ft2
7. Windows- Description
Area
c. N/A
R=
ft2
a. U-Factor: Dbl, U=0.33
113.31 ft2
12. Ducts, location & insulation level
R ft2
SHGC: SHGC=0.23
a. Sup: Attic, Ret: Main, AH: Main
6 356
b. U-Factor: Dbl, U=0.33
45.94 ft2
SHGC: SHGC=0.21
13. Cooling systems
kBtu/hr
Efficiency
c. U-Factor: Dbl, U=0.55
17.78 ft2
a. Central Unit
28.4 SEER:15.00
SHGC: SHGC=0.70
d. U-Factor: N/A
ft2
SHGC:
14. Heating systems
kBtu/hr
Efficiency
Area Weighted Average Overhang Depth:
2.639 ft.
a. Electric Heat Pump
28.2
HSPF:8.50
Area Weighted Average SHGC:
0.272
8. Skylights Description
Area
15. Hot water systems
a. U-Factor(AVG): N/A
ft2
a. Electric
Cap:
40 gallons
SHGC(AVG): N/A
EF: 0.94
b. Conservation features
9. Floor Types
Insulation
Area
None
a. Slab -On -Grade Edge Insulation
R=0.0
1780.00 ft2
Credits (Performance method)
Pstat
b. N/A
R=
ft2
c. N/A
R=
ft2
I certify that this home has complied with the Florida Energy Efficiency Code for Building
Construction through the above energy saving features which will be installed (or exceeded)
in this home before final inspection. Otherwise, a new EPL Display Card will be completed
based on installed Code compliant features.
Builder Signature: - -� Date:
Address of New Home: City/FL Zip:
"Note: This is not a Building Energy Rating. If your Index is below 70, your home may qualify for energy efficient
mortgage (EEM) incentives if you obtain a Florida Energy Rating. For information about the Florida Building Code,
Energy Conservation, contact the Florida Building Commission's support staff.
'"Label required by Section R303.1.3 of the Florida Building Code, Energy Conservation, if not DEFAULT.
4/26/2021 8:53 AM 7.0.00 - FlaRes202O FBC 7th Edition (2020) Compliant Software Page 1 of 1