HomeMy WebLinkAboutJacobsen Manual.pdf4 MANUFACTURED HOME SET—UP *SITE PREPARATION (A.) BLOCKING (B.) LEVELING (C.) ASSEMBLY AND CLOSE-UP *TIEDOWNS (SEE SET-UP MANUAL ADDENDUM) *ELECTRICAL CONNECTIONS *PLUMBING CONNECTIONS *A.C. CONNECTIONS *ON SITE VENT CONNECTIONS SITE PREPARATION *MISCELLANEOUS DETAILS IF YOU ARE GOING TO LIVE IN A PARK, YOUR HOME SITE WILL BE READY OR BE PREPARED FOR YOUR HOME. IF YOU INTEND TO INSTALL YOUR HOME ON YOUR OWN LOT (NOT IN A PARK), SOME SITE PREPARATION WILL BE NECESSARY. ALL GE (AT THE ION ND MUST SLOPE IAAMINIMUM OF 1/2TAPER TFOOT IAWAY ROMTE) MUST ETHE FOUNDATION OR SKRDIVERTED AWAY FROM HTINGOF FORA FIRST 10'. THE SITE MUST BE GRADED TO PROVIDE FOR STORM RUN-OFF. SPECIAL CARE MUST BE TAKEN WITH THE AREA DIRECTLY BELOW YOUR HOME TO PREVENT WATER FROM PONDING AND/OR PUDDLING UNDER YOUR HOME AND SUPPORTS. IF THE SPACE UNDER THE HOME IS TO BE ENCLOSED WITH SKIRTING OR OTHER MATERIALS, A VAPOR RETARDER (I.E. POLY...) MUST BE INSTALLED TO COVER THE GROUND UNDER THE HOME (SHALL BE 6 MIL. AND ALL SEAMS TO OVERLAP 12" MIN.) REPAIR ANY TEARS OR VOIDS IN THE RETARDER BY PATCHING WITH LIKE MATERIAL, MAINTAINING A MINIMUM 12" OVERLAP AND SEALING JOINTS WITH DUCT TAPE OR MASTIC. PIER SUPPORTS MUST BE PLACED ON UNDISTURBED SOIL (ALL GRASS AND ORGANIC MATERIAL MUST BE REMOVED) OR FILL WHICH IS COMPACTED OR FULLY SETTLED (SEE SU-4.1, DETAIL 'A' AND DETAIL 'B'). IN AREAS THAT ARE SUSCEPTIBLE TO FROST, PIER SUPPORTS MUST BE BELOW THE FROST LINE. OPTIONAL: PIERS MAY BE PLACED ON CONCRETE RIBBONS 6" X 16" X LENGTH OF HOME MINUS 18", (A•) BLOCKING REINFORCED WITH WELDED WIRE MESH. UNLIKE A STANDARD HOUSE, YOUR MANUFACTURED HOUSE DOES NOT NEED A FOUNDATION TO SUPPORT IT COMPLETELY AROUND ITS PERIMETER. THE STEEL FRAME OR CHASSIS USED FOR TRANSPORTATION ALSO SUPPORTS THE HOME AT ITS HOME SITE. THE STEEL FRAME MUST BE SUPPORTED (SEE SU-01-0003 & 0004) TO PREVENT YOUR HOME FROM SAGGING, AND TO KEEP IT LEVEL. NOTE: ADDITIONAL PIERS ARE REQUIRED AT ALL RIDGE BEAM SUPPORT COLUMNS (EXCEPT AT THE FRAME HEADER), SHEARWALLS, AND AROUND THE PERIMETER OF YOUR HOME. CHECK FOR THE APPROPRIATE DETAILS FOUND IN THIS AND THE SET-UP MANUAL ADDENDUM FOR SPECIFICS FOR EACH TYPE OF ADDITIONAL BLOCKING REQUIRED. SPECIFIC BLOCKING LABELS ARE FOUND ON THE EXTERIOR SIDES OF YOUR HOME. MAXIMUM HEIGHT OF A PIER IS DETERMINED BY THE TYPE OF PIER USED, CHECK THE APPROPRIATE DETAILS FOR THE PROPER CONSTRUCTION OF EACH DIFFERENT TYPE OF PIER. (ALSO SEE TIE -DOWN REQUIREMENTS TO DETERMINE MAXIMUM HEIGHT FROM GROUND.) ALL SUPPORTING STRUCTURES NOT LISTED OR SHOWN IN THIS MANUAL OR SET-UP MANUAL ADDENDUM MUST BE APPROVED BY A REGISTERED PROFESSIONAL ENGINEER. (B•) LEVELING PROPER BLOCKING SEQUENCE IS ESSENTIAL IN THE LEVELING OF YOUR HOME. (SEE BLOCKING DETAILS ON SU-01-0002 .0003, & 0004) FOR THE RECOMMENDED BLOCKING SEQUENCE, TAKING CARE TO CHECK YOUR LEVEL BETWEEN EACH STEP AND SUPPORT. RECOMMENDED LEVEL IS A 48" CARPENTER'S LEVEL. (SEE ACCEPTABLE LEVELING GUIDE BELOW) BUBBLE HAIRLINES CARPENTER'S LEVEL 1/8' IS MAXIMUM ACCEPTABLE SPECIAL NOTE FOR AlL 80M C SET IN FlORIDA CHECK FLORIDA STATUTE 15C FOR ANY OMITAIONS THAT MAY AFFECT THESE INSTRUCTIONS. OCJ♦o JACOBSEN HOMES NOTICE: ORANN BY: ppTE; REV. ETIFR: ❑ THESE PROPA1NINSANDDRAMWGSME O.A. 11-21-06 ORIdNA4 FRd'ACOBS, AND NUFAM IIAL DHANING TITLE j1 P.O. BOX 368 MA7QdCH AT JACDBSEN MANUFACTURING LH_-f( IF SAFETY HARBOR, FLORIDA 34695 INC. OOT MATERIAIB ARE SWW 8 AND TO THE MANUFACTURED HOME SET-UP PHONE (727) 726-1138 KKryf NFIDDM& MD fR�pl pMO DRANING NUMBER; SU-01-0001 (to—oa—oa) DETAILS "A" AND "B" YAM FRAIIF I—BI NOTES: (( •�7,2;.y�L� / PRESSIAE lAEA1E11= 2 NOTE 111) 1 R .B HOLLOW LOCKS TT I—BEAMFS LSOINCGKL PER CAPPED WITH SOLID CONCRETE 54" MAX. PIER BLOCK DRY STACKED BLOOf (01. 4• INCH) AT PERIMETER & MATING LINE. (PIER SYSTEMS ANY TALLER V X B' X 1C CLIFED WSW BLOC - MUST BE APPROVED BY A WITH VERTCAI- OPENCELLS1 LICENSED ARCHITECT SE TABLE I FOR PER TOOTER - OR ENGINEER) SLING AND SPACING = 2. MAXIMUM PIER/PAD PROJECTION: 9iC81GI0N5 (PACE 11) _ � SEE OTHER DETAILS (SE SI-IA FOR 16 X 16 PRECAST PER PAD S'AWIG) c - $ 6 3. ALL PIERS MUST BE CENTERED ON FOOTERS MUST BE WITHIN 1/2- OF PLUMB PER 3285 STANDARDS. SE R07E 4. MARRIAGE WALL OPENING PIERS TO BE WITHIN 6' OF OPENING RF310VE ALL ORGANIC WTERAL ON EITHER SIDE OF COLUMN. AND PLACE PAP ON STAID (WHEN REQUIRED FOOTER SIZE BELOW FROST LNE PER LOCAL PREVENTS A SINGLE STACKED CODE RECIII EWENTS SE NOTE n PIER FROM MEETING THIS, USE DETAIL FAF (DD@lS10N yA1atE55 WITH YAX. %ENSI S WITHG) A DOUBLE STACKED PIER. GOOD UP TO 28 X 28 FOOTER.) P SOIL 5. MINIMUM PIER PAD THICKNESS: A. 4' MIN. FOR PRECAST UNITS UP TO 16' X 16" B. FOR CAST IN PLACE FOOTINGS ON 2000 PSF SOIL (MAX.) SEE NOTE 13 THE MIN. THICKNESS IS MAX. FOOTING DIMENSION DIVIDED BY NOT LESS THAN STWS (DECAY �TANT). _ 6. FOOTING HAVE ALL FOOl1NG CONCRETE TO HAVE �/� PR1� �� WIC (Si NOTE jl1) COMPRESSIVE STRENGTH. (tc) = 3000 PSI (MIN.) CAPPED WITH SLID 7. PLACE 6 MIL POLY ON GROUND PRIOR CONCRETE BOO( (ION. 4' THICK) TO POURING FOOTING CONCRETE. (ALL SEAMS TO OVERLAP 12- MIN.) X 8' X IV CEO MASONRY B. PIERS SUPPORTING THE )—BEAMS - BLM WTH OPEN COLS VERTICAL TO BE WITHIN 24' OF BOTH ENDS TR-DOWN STRAPS ATTA - (SEE NOTE p FOR YAX PH HBCIRS AND NO MORE THAN 10' O.C. TO DEAII CCIUIONS ON AND DETAL ABDO 9. PIERS MAY BE OFFSET UP TO 6' EACH SCTION TD BE CCNHECIED IN EITHER DIRECTION ALONG THE _- TO A DOILI ILE HEADED ANOINT TABLE FOR PER I —BEAMS TO ALLOW FOR PLUMBING, T = F001IR MIND AND SPACING SPECIFICATIONS 10. ELECTRICAL, ETC. FOOTING CONSTRUCTION MUST SF.E NOTE #4 / AM 10 COMPLY WITH LOCAL BUILDING CODES. COMPLY 1—(REI OOVEDRUM IIAIERIAL 11. WOOD SHIMS, WHEN REQUIRED ARE TO DOWLE HEADED ANCHOR PLACE PAP QV STABLE SXL BE USED IN PAIRS INSTALLED IN OPPOSITE DIRECTIONS AND FITTED BELOW FRIBA PER LAICAL CODE REODOMEM TIGHT BETWEEN THE —BEAM AND PIER / CAP. SHIMS MUST BE MIN. 4' LONG SE NOTE QJ DETAIL 'B' SEE NOTE 12 BY 6' WIDE AND NO MORE THAN ( VAIBS WITH 1' IN THICKNESS. AIMLOWAELE SOL BEARIeg®DOOI ADPA6®r %A owpom - - .. de DAPIA APPROVAL a� m APPROVED BY m Pdo 484 e - a o�,g �- � g Revised ��'`��Deco - 17, 2008 N1PINC. m13 A ;" TATE OF a ILA® ®��a 0 FEDERAL MANUFACTURED HONE CONSTRil AND SAFEIT STANDARDS o mAe��S, C O 1 r Cps>0o R JACOBSEN HOMES 9pE)p WFSE9'E64mATPRA1 W"l=ARE oamul. vRrovErAm Alm InMNEM MML DRAWN BY. O.A. DAM 09-07-93 REV. LETTM n DRAWING TITLE 'A° °B' W, `" M �" DETAILS & {1 P.O. BOX 368 IDWEI SAFETY HARBOR, FLORIDA W95 WMW FM 9M FUFM AID WSf IL 12-15—OB ( ) DRAWING NLUBM PHONE (727) 726-1138 KEPT gLFFMUL AW SIFT FIN 0011015L SU-01-0001.1 Jacobsen Homes Load at Frame (each 1-Beam location), Perimeter elderwall area), and Mating Line for Homes Requiring Perimeter Supports fin Pounds) - ALL WINOZONES, ALL EXPOSURES, AND ALL FLUOR SYSTEMS IJOIST SIZES) Maximum Spacing Location South Roof Load Zone (20 P:0 12 ft. Max Section Width 14 ft. Max Section Width 16 ft. Max Section Width 4 ft. Frame 1260 1460 1660 Perimeter 1202 1422 1642 Mating Line 2164 2604 3044 6 ft. Frame 1890 2190 2490 Perimeter 1803 2133 2463 Mating Line 3246 3906 4566 8 ft. Frame 2520 2920 3320 Perimeter 2404 2844 3294 Mating Line 4328 5208 6088 10 ft. Frame 3150 3650 4160 Perimeter 8 ft. Maximum Pier Spacing along the Perimeter and Mating Line (See 8 ft. Row) Mating Line Loads on supports of a given type (frame, perimeter, mating line) can be assumed to be equal if support spacing is equal. However, if different support spacings are utilized then each support with different spacing shall be calculated separately. This table is designed for use with multi section homes. However, if a single section home is being installed, the perimeter spacing should be used along both si dewall areas and the mating line spacing can be ignored. Alternate Perimeter Pier Placement � eel l,Y ;ono✓ \' Perimeter not shown for clarity (do not cut out) Added import above pier Pier 1. As an alternate to placing the perimeter per directly underthe perimeter joist on the floor system, the pier may be recessed up to a maximum of ten inches )10") from the outside edge of the floor system (sidewall side ONLY) when a minimum 4x4 P.T. that ,pans a minimum of two floorjoists is used on top of the recessed a e, (see detail above). 2. The ten inches 110") maximum set back is measured from the outer edge blithe floor system to the vertical face of the pier. 3. This detail may be applied WALL floor systems and ALL floor widths, ALL Joist types and ALL Joist Hocing in ALL wlndzones and exposures. d. Also refer to SU 01 0005, SIT 01-0005.1, and SU-01 0005.2 5. Refer to other detadsfor pier and pad sizing requirements. 6. This detail may be applied to EXTERIOR WALL APPLICATIONS ONLY. No. FE10505134 . y STATE OF / 2u ,,`'Of\i `�- ,sssl 5/6/2014 �e Aer n u so Ig11iLtt::: Cr1 IS Z Jacobsen Homes Fnntinn Capacities 81n, x 16 in. [single stack) pier 161n.. 16 in. Freund lack) is, unredlor[ed un,einlor[ed Soil lnbdmmn Mladerve r oearn, capa[ititY F10619 sooting Maaimum Posting m541mplace M(aimui Footing [as41n-Place [pall S'ue lint area (in.a) Capacity Flee.) minimum pace, jib,.) stinfleforn thickness (in thickness (in.) 16 x 16 256 L600 6 20x20 loo 2,600 6 2,600 6 N a 24x24 S76 3,700 6 1,700 6 00 30x3a 900 5,00 a s,aoo 6 c36x36 4296 ],900 l0 6,100 8 42 x 42 1,164 10,700 rare 1 10 10,70 10 E8:r q8 2'ra" 13,100 12 13,600 10 I6 a I6 256 2,500 6 2,500 6 20 a 20 no 4,000 6 4,000 6 a24.:4 S)6 51600 a 5,300 30a30 too 8,501 l0 8,900ar 1.a36 1,296 I2,I00 t0g2a42 4�1 l,]64 Ib,SM IE Illicita48a48 2304 2L200 0 14 2L6o0 0 16 x16 256r 00 6 1,400 6 20x20f40000 6 5,300 6 24x2400 8 7,700 6 to.10]g0 10 11.900 8 N 3"36]M o 15 16,9N r 1D 42x42 1,76470 yan. 4 16 22,700 ran 1 It Isx16 2S6 4,300 6 4,300 6 n 30a 20 4.0 1,700 6 6,700 6 O - 24.14 576 9,ti00 side a B 9,700 6 0 � 30a30 900 14,900 111. to 1s,000 3 N 36.36 1,296 20,700 rise 31 21p00 rate 1 10 16. 16 256 5,200 6 S,200 6 20a2o 400 8100 area 6 8,100 6 or .`.)O 24x24 576 11.500 10 11,700 6 A 18100 xm. 4 8 30.30 900 17,800 ite. . 12 �1 M 36.36 1,296 25,400 save 14 35,900 rwa I10 q x l 16 x 16 256 ],000 6 7,000 6 N 3`r d 20a20 400 10,gW 8 10,900 6 '31 24e24 5]6 15,P* 10 15,6Lb 8 h�a 0x3 30 900 33,300 rare s 12 24.200 pan c 10 1. the looting Seen hce'nar.for square pads and are based on the area l'n°L sLPar and pending required for the loads sho'.vn. Other onligurat ons. Such as rectangular or circular :onfig,rat ons an be used, provided the area and deylhh final ur g,iter lips the area ,no Jeplh of be square looting shown in the hale, and thedistance Oamthe edge lire pier to the edge of he lcotingh no, let, Iden the thickness of the footing. 2. Tile bindc,implace values an be ,ad for Fd, unr einformd Ades, un-111 feelers. 3 - he capacity values listed have been reduced by the dead ad of the concrete footing. 4 le block piers must not closed their design capacity of 8030 flat far in, v 16 in. dells stack bed and 16.CCO Its for 16 in. s 16 if : o.d. track block, S. A r,,srrcd professional engine regilered mh.tect cshall prepare!he benign,is the Sold exceetivhe[apart'/ 'or single or double sad enacts trod piers shown in then note 4 e On the trome[h[xam) zengleslack bloc, per hall net e.ceed 36"M1IgM1Iree Momole 4lur Dupe. tyl and a Ju,Ilt slack block r wGbintedodedbloc ssha:lnoticeed67-1',1 fesfoomolec ormaKmum...it yl.Ide-risedled along the perimeter or the Teller line a angle lack Shia is shall not •+coed St mne.all lie note I for manml.m[]Ral,) Any peen that ee[oed less ueghs tpeULod it Only Icetnole shall be designed by a regeta/ed plains anal engineer or registered arcolten ] Jpured Fca n-plaral p/preatl[pn[IPle loolingta 2apprcprla!^f0/call spil[ypci. 405petb[IoelrngtlCadtl s floo .,te Usedin ...chheawiththep,drnanuh[turei I'llec'cry and must be cerlfled for use" sml:Ipy(rtalun al the Me, list:d enJ Iffi:ed (car roe rucu ndd load id,.onR SU-01-0001.3 MOBILE HOME SET-UP NOTES. 1. JACKS TO BE RATED AT 5 TONS. 2. ALWAYS USE A SUPPORT UNDER JACKS. 3. FOLLOW BLOCKING INSTRUCTIONS. 4. FOR MULTIPLE WIDES SET HEAVY SECTION FIRST. E 1. LOCATE HOME ON SITE AND LEVEL AS CLOSE AS POSSIBLE USING HITCH JACK. 2. SET SUPPORTS (BLOCKS #1) UNDER BOTH I -BEAMS JUST FORWARD OF THE FRONT SPRING HANGERS. 3. SET SUPPORTS (BLOCKS #2) UNDER BOTH I -BEAMS JUST BEHIND THE REAR SPRING HANGERS. 4. LOCATE SUPPORTS (BLOCKS #3) MAXIMUM 24" BEHIND THE FRONT CROSSMEMBER. 5. LOCATE SUPPORTS (BLOCKS #4) MAXIMUM 24" FROM THE END OF THE HOME. 6. ADDITIONAL SUPPORTS (BLOCKS #5) MAY BE NECESSARY BETWEEN 1 & 3 AND 2 & 4, IF THEY ARE NEEDED THEY SHOULD BE SPACED EQUALLY, MAXIMUM SPACING 10'-0n. 7. IF YOUR HOME HAS 4 AXLES ADD BLOCKING BETWEEN THE MIDDLE SET OF AXLES. 8. FOR SINGLE WIDES BLOCKING IS COMPLETE. 9. FOR MULTIPLE WIDES REMOVE ALL SHIPPING BATTENS AND VISQUEEN AND SET LIGHT SECTION(S) AS CLOSE AS POSSIBLE TO THE ALREADY SET HEAVY SECTION. 10. JACK THE LIGHT SECTION(S) TO THE HEAVY SECTION USING JACKS AND COME-ALONGS. 11. FOLLOW BLOCKING SEQUENCES 1 THRU 7. NOTES: 1. THESE FOUNDATION SPECIFICATIONS HAVE NOT BEEN DESIGNED FOR FLOOD -RESISTANT SPECIFICATIONS. 2. PERIODIC RELEVELING MAY BE NECESSARY BECAUSE OF THE WEIGHT OF THE HOME AND SETTLING THAT MAY OCCUR. JACOBSEN HOMES NOTICE: 1HESE L PROC IETAR AND OIMNFIDE ARE AN6 CONRDEN9A1 pt141NA1, POF DRANK BY: O.A. DA S 06-06-94 REV. LETTER: NEIDIC P.O. BOX 368 MCAAY, IALS AT ,NCLS ARE M IURINC ORANINC llTlE: MOBILE HOME SET-UP 2 INC. S OVIDED CH Sal �(AdTT WSTBEBF SAFETY HARBOR, FLORIDA 34695 PHONE (727) 726-1138 FOR RAB ,VO KEPT CUfO IM NO SEW M OTHERS. DRANINC NUMBER: SU-0I-0002 (09-30-08) a 5 SEE NOTE #77 SEE NOTE #6 -,,,,--SEE NOTE #2 NOTE #1 NOTE #5 NOTE 3 # TYPICAL SINGLE WIDE BLOCKING (SEE SU-01-0004 FOR NOTES) SEE NOTE #7 SEE NOTE #6 t' n' NOTE #3 TYPICAL DOUBLE WIDE BLOCKING (SEE SU-01-0004 FOR NOTES) HOMES ,F NOTICE: DRAWN BY: DATE: ❑❑❑❑ H JACOBSEN OMES WISE SPEGRCATIONSAND DRAMINGSME S•A. 6-6-94 ❑❑.❑ MATERIALS PROPRIETARY, AND NUFACT RING DRAWING TITLE: DOUBLE WIDE BLOCKING MATERIALS AT JACORIALS SENARE MANUFACTURING WE ❑„❑ P.O. BOX FLORIDA INC. SUCH MATERIALS ARE PROVIDED U WE SAFETY HARBOR, 726-11 34695 KEPT CO FOR SPEORC PURPOSES AND OUST RE DRAWING NUMBER: ❑❑❑❑ PHONE (727) 726-1138 KEDi CONFIDENDAL AND SECAEI fNOu DINERS. $U-01-0003 6 SEE NOTE #7 SEE NOTE #6 72 1 3 NOTE #5 SEE NOTE #2 f I NOTE 3 r SEE NOTE #4 NOTE #5 I NOTE #1 p SEE NOTESEE 3 4 2 1 NOTE #6 5 5 3 TYPICAL TRIPLE WIDE BLOCKING SEE NOTE #7 NOTES #1-MAIN FRAME I -BEAMS #240CATE PIERS UNDER FRAME I -BEAMS #3-LOCATE PIERS UNDER CLOSEST FLOOR JOIST EACH SIDE OF OPENINGS 48" AND LARGER. (I.E.-RECESSED ENTRIES AND SL. GL. DRS.) SEE TABLE FOR PIER FOOTER SIZING PAGE 10. #4-LOCATE PIERS UNDER MARRIAGE WALL PERIMETER JOISTS WITHIN 6" OF EACH SIDE OF OPENINGS. 48" & LARGER AND RIDGE BEAM COLUMNS. SEE TABLE FOR PIER FOOTER SIZING SU-01-0030 AND SEE DETAIL 'B', SU-01-0010. #5-AXLE ASSEMBLY CENTER LINE #6-SEE TABLE I FOR PIER FOOTER SIZING AND PIER SPACING INFORMATION SU-01-0040, AND DETAIL 'A' SU-01-0010. #7 )CKING SEQUENCE NUMBERS, SEE SU-01-0002 FOR PROPER BLOCKING PROCEDURES. ,( HOMES FA JACOBSEN HOMES NOTICE: THESESPECIFICANDNSANDORAMNGSARE PROPRIETARY, ANO DONFIDENUFACT RING RO RIETMYEN MANOFACTURINGP.O. DRAWN 8Y: S.A. DATE: 6-6-94ORIGINAL, REV. LETTER: oRAx+Nc nnE:TRIPLE WIDE BLOCKINGMATERIALS BOX 368 HARBOR, FLORIDA 34695 INC. SUN MATFNIALS ARE PRONGED TD WESAFETY REOPIEMT FM SPECPIC NVDSES AND MUST BE DRAWING NUMBER: $U-OI-0004 PHONE (727) 726-1138 KEPT O'OHFIDENDAL AND SECRET FROM OTHERS. 7 ADDPL REO"D PERIMETER BLOCKING - ALL FLOOR WIDTHS [THIS BLOCKING IS IN AMMON TO OTHER BLOCKING REBURIED IN THIS MANUAL -All FLUOR WIDTHS AND JOIST SUM TYP_ FIREPLACEs ON smmW OR MARRIAGE WALL HOST BEAM NOTE PEItA1ETER BLOOIONG REOIRED AT 48' OC. MAX R9R TO SU41-ODD8 ANY SIZE TLM ANOTIR SHOWER AT BIDEWALL OR MARRIAGE WALL PEAME701 BLOD]NG IS FEUD IMAFRIM>rt AND: TOTE: LZEL ROM SYSTEM REST (SNETAL TO SIDETIAL OR UNDER LAM SIDE OF ALL EXTERIOR DOORS LOCATED OR GIBEWALL S 2 OR MORE 46 IIT NOW PIERS REQUIRED AT EACH END —� AND BETWEEN EACH OPENING RECEM AREAS RECIARE PM SPACED 64' O.C. MAX (11t OR LESS N DEPTH) EACH END OF RECESSED AREAS 1:R1EAlSAS w/50E BAY t+Eaulf HERS SPA(ID 64' O.0 YAX. THIS ALSO APPLIES TD ALL EN DWALL MAY WINDOWS UNUENS SUPPORTED DY A FRAME MEMBER GARDEN TUB AT sIDFW'ALL OR MARRIAGE WALL 6C O.C. MAX O CABINETS ALONG SIDEWALL OR MARRIAGE WALL. (APPLIES TO BATH CABINETS 80' OR GREATER N IFNCTH) (SATE BLOMC MAY BE USED FOR MULTIPLE 46 1/1 VINDOXS) 95' LN WREN MAX SPACING wH1) saw WTALNG RFAETER am NOTES: 1. FIR THE ADDRO 1 %DCWG RMURED AS WARD ON USE 16' X Id PER PADS W. L LOCATE BANK UE9 PEAIEER XIST OR SPIN 6' OF THE DO OF 20 BETS LOCATED AT 15' OC W k 3 DIM PUS ARE N NOSIEST 10 ANY ODER RCIIIED PIM AM MAW TEE 4. PEISIEER BLOOMS IS IEOMED BEER RE BOORS WADE k SIEETWIA) 96' aC MAX. 5 PUS USED FOR PER14lEA BMPORT MU6R BE PWIL FD HN THE LUG MOLTlOH PNWM TO THE PU IFA RA- 6. RDN PERIM B.00BIG G WAIR D, ANY WTNO LIE OPEN SPAN SEATER THAN 10', WSf HAVE NTFTERAKIE PERS PLACID AT MAX Id 04 UCFPT IN' VIDE FIRS, $9 SPEU4. NOTE • .. RM TO W-OI-MI NO SU-01- 0S.2 FOR 2A ROO1 SYSTEMS Q Zwe Lm 5 MAR 20 2014 C 0. a'v Ftdeal MA-f.m m Ana SeW26TmWdt NOTICE: u M o.. O.A. onto 4-12-00 JACOBSEN HOMES THEM SFEFlCATXHS AO MUMS ARE QOW& PRMWMYAW cOHODHNAL DRATNC TRLf: WIMALS OF J&CO H MAMWACTUiNG ADDITIONAL BLOCKING Ll P.O. BOX 368 NG SOON YATBULS AW PROVED) TO THE SAFETYHONES (813) 726-1138 lUT WCWDNttVA1DHM 1RX MS DRAIINO NlA%9fR: SU_01-0005 (03-19-14) (APPLICABLE TO ALL Ii PERIAL AND Dl LORO COTTAGES $TH 184' FLOOR {MOTHS -SEE FL-01-D009.2) ON SITE PERIMETER BLOCKING O.C. SPACING 16 X 16 PIER PAD 17 X 25 PIER PAD Vk 1000 PSF SOIL 1500 PSF SOIL 1000 PSF SOIL SIDEWALLSMATELINE WALL 48"/24" 64"/40" 64"/48" MAX LOAD INCLUDING PIER AND FOOTER ' 1778# 2667# 2950# JACOB8EN HOMES P,O, BOX 368 SAFETY HARBOR. FLORIDA 34695 PHONE (727) 726-038 EfVS6'� No 454 1t rd --• Q STATE OF 40RT�P�� v d®'E'On -9/{) n , t" ALL YPNIDZONES ALL EXPOSURES 20 PSF ROOF 10 PSF D.L. C-FL- 89.01 - 89.03 APPROVED BY May RA 07,2009 oH5LCTlaNADM[m5Twans SU-01-0005.1 9 PERIMETER BLOCKING FOR 16O" 113'.4"1 FLOOR WIDTHS USING 2x6 FLOOR SYSTEMS (19.2" SPACING) (IMPERIALS AND DELORO COTTAGES WITH 2x6 FLOOR JOISTS) PERIMETER BLOCKING IS REQUIRED (SIDEWALLS & MARRIAGE WALLS] H4" ON CENTER MAX. SPACING, USING 16x16 PIER PADS MIN. ON 1000 PSF SOIL. (EXCEPT AS NOTED ON SU-01-000SI (SEE SU-01-0005.1 FOR 1B4" FLOOR WIDTH, WITH 2x6 FLOOR JOIST, PERIMETER BLOCKING REQUIREMENTS) [SEE SU-01-0005 FOR 184" FLOOR WIDTH, WITH 2xB FLOOR JOIST, PERIMETER BLOCKING REQUIREMENTS] NOTES: 1. PRE-FABPoCATED PIER PADS MAY BE USED AS AN ALTERNATE TO THE CONCRETE FOOTINGS SPECIFIED IN THE JACOBSEN HOMES SET-UP MANUAL 2. THE PRE -FABRICATED PIER PADS ARE TO BE INSTAUSD PER THE MANUFACTURERS INSTALLATION INSTRUCTIONS AND MEET THE MINIMUM PIER CAPACITIES SHOWN ABOVE. 3. ALL OTHER REQUIREMENTS ARE TO BE ADHERED TO AS SPECIFIED IN THE JACOBSEN HOMES INSTALLATION INSTRUCTIONS. z a MAR 19 2014 � O a � CL Fed.1 Manufaev-ed m QH.., C,wmnon O Md Safety Standards N070E �"" �CYOUNG ......11-18-2011 JACOBSEN HOMES THESE SPECIFICATIONS AND DRAWN ARE ONCiVL. PROPRIETARY, AND CDNHCFNILLL DRAWING TITLE' FRE MATERIALS JACOBSEN MANUFACIUiN6 PERIMETER BLOCKING IMP -DC P.O. BOX 368 INC. SUCH MATERIALS ARE PROVIDED TO THE SAFETY HARBOR, FLORIDA 34695 IECPENF FOR SPFnC MMS5 MID MASH BE DRAWING NUMBER: $U-01-0005.2 03-19-2014 PHONE (813) 726-1138 I®T COMIDENML AND SECRET FROM OTTERS BLOCKING (PIER) LABELS LOCATE THESE LABELS AND CHECK THE APPROPRIATE MANUAL FOR PROPER INSTALLATION OF BLOCKING AND PIERS.. SHEARWALL PIER LOCATIONS SEE SET-UP ADDENDUM FOR SPECIFICS ,a BOTTOM OF EXTERIOR SIDING AT SIDEWALL SPECIFIC PERIMETER PIER LOCATION SEE SET-UP MANUAL FOR SPECIFICS BOTTOM OF EXTERIOR SIDING AT SIDEWALL NOTES: 1. THIS IS INCLUDED IN THE HOME OWNERS PACKAGE. COLUMN PIER LOCATION SEE SET-UP MANUAL FOR SPECIFICS (LOCATE THESE PIERS AT b, THE MARRIAGE LINE) A JACOBSEN HOMES NOTICEAM TRESS sPErnuEaHR AND ARE AiAWn tl7: M.T. " 05-20-06 REV. lE1lER P.O. BOX CNCINAL PROPRIETARY. AND CON{ICENDAL CMIDS MATERAHS OF JACOBSEN MANLFACIIIIIFp DRAWING RILE: BLOCKING PIER LABELS „ SAFE R` . 726-113IDA 34695 ING SUCH MAIBSALS ARE PHEONFD TO TIE H DRAWING MUWBEC HONETY 27)R. SU-01-0006 (09-O -12) 10 11 BLOCKING IS N AMMON 10 BLOcKK RFOIIRED N THIS MANUAL) MAX I ADDED I -BEAU ISO EXTERIOR WALL I I RE(EiSfO PORCI REM PIERS SPACED64' O.C. PER UNDER ADDED (AND MRS AT PORCH POSTS) AS SHOWN 640 O.C. MAX PIER SPACING AT UARRIAGEWALL NOTE DISTANCE BETWEEN EDGE OF PIER AND EDGE OE I'= POST TIP. PORCH POST NOT MAY JfAS (S 1�TM O . 5 1/2' MAX TIP. PORCH FLOOR TIP. Pon FLOORING DOUBLE POO PFRIETER RA1L- TV. TIE-DOWW STRAP (SEE OTTER DETAILS) 16'X16'MIN. PIER PAI CRO; TYP. PORCH POST TIP. PORCH FLOORING FLOOR JOIST •(2)2X6PTXMrUK. BRIDGED BEIVI DN 2 PORCH FLOOR JOISTS PIER (6'X6'X161 ,IIJ!LL 2 X 6PT X111*4K DGED BETWEEN 2 LOIN FLIED JOISTS LONGITUDINAL VIEW A2 DETAIL 'A' DCIBIE PORCH PETOUE ER RAIL NOTES• " . NOTES: _ _ L PAI15 ON 100E PSF dASNOTED ABOVE (USE IC X 16' PIER 2 LOCAIE BLDCOIIO OW PEIdNEIER JOSr OR NRMN S 1/t Or ENO OF 16' O.C. . S PIR6 m BLODKK 15 REOARED UNDER PORCH AT EACH POST (61' OG VAX) 4. ADgRD1AL IL0004 ACCUSED AS NNOATED ABOVE UNDER CENTER OF ADDED 1-BEAM i (61' O.C. MAX) 5. SEE MITER DETAILS FOR ODOR REOUBED ��a RUH HOUSE 1Kw: 6.ADDOOI-EMATPM/XEOWALL wY9FHON w. Tit -Dow STRAP (SEE DIM DETAILS) USE DETAIL T ONLY WHEN CUMOG R IS ON FLOOR JOIST waxy am PORCH POST 2al•,,•As- 11 PER UNDER ADDED I -BEAM TWP. PORCH POST PORCH FLOOR JOIST •(2)216PTXI6'UK moo BETWEEN 2 PORCH FLOOR JOISTS FIER(6'X6'X161 IC X 16' UK PIER PAD � CROSS SECTION VIEW BI TIP. PORCH POST 'NOTE: DISTANCE BEMEEH EOOE OF M. PORCH ELOORNG�,TI2�� �PIER AND EDGE OF PCID POST PORCH FLOOR JOIST MAY NOT MEED S 1/2- (2) 2 X 6 PT % 16' nP TE-OOMN STRAP P LOOR JOISTSlk- (SEE OTHER DET/A5) IDNGMUDINAL. VIEW R2 A;ormop APPROVED BY 000 Iec 13,2006 NAINC. F(U[ML YPXUf•CNRO NaMf fLNSiPUE11P1 NO Sni FIY SlaxowOs xoncE -m, ... R.R. 11-28-06 JACOBSEN HOMES �,„�„ �,NOOWMI AK AW4 TITLE- ADDITION CEM vA1QYAs OF RULS A 1 YANM TO NC PORCH BLOCKING — P.M, BO% 366 DK s K YOF AWO SDI AMU Gm i0 11[ F9SAFETY NARBON• RORIOA y169S 6(Li1@M?Mi1G� 1Aa MAWVIO NNIBER: SU-01-0007 PHONE (6U) 726-1136 John C. Doeden, P.E. 15133 County Road 22, Goshen, IN 46528 April 16, 2014 To Whom It May Concern: Subject: FBC Wind Speed conversion —Allowable Stress Design (asd) vs. Ultimate (ult) As the consulting engineer for Jacobsen Homes, Inc, it was requested by Jacobsen's engineering department that I convert wind speeds (Vasd) presented in their package for the old 2004 Florida Building Code- Residential to the 2010 FBC wind speed (Vult). Page SU-01-0008 in the Jacobsen Homes' HUD Set -Up Manual was based on the 2004 FBC-R Code that was in effect when this detail was submitted for approval and included in the Set -Up Manual. The 2004 FBC wind speed was based on wind speed=Vasd (mph). Since that time Florida has adopted the 2010 FBC which is based on wind speed= Vult (mph). The loads that are derived from Vult utilize a factor of 0.6 whereas those based on Vasd do not utilize a reduction factor. Therefore, converting loads from Vasd to Vult results in the following equivalent wind speeds: 120 mph Vasd, Exposure B = 140 mph Vult, Exposure C 140 mph Vasd, Exposure B = 164 mph Vult, Exposure C The reference standard contained in the 2010 FBC for Vult is ASCE 7-10, while the reference standard in the 2004 FBC for Vasd is ASCE 7-05. USt((GtPF��� ?Doeden, John PE 45404 15133 u, * = Goshen, IN 46528 Vo :¢ Phone: (574) 825-76STATE of , w� %p. 11is�ONA! E%A°�� 13 12 ATTACHMENT TO HOST BEAM ATTACHME14T MAY BE FLUSH WITH HOUSE -� HOST BEAM STRUCTURE ATTACHMENT SECURED DIRECTLY TO FACTORY INSTALLED HOST BEAM (THIS IS IN LIEU OF 'FOURTH WALL CONDUCTION") STRUCTURE ATTACHMENT INSTALLED ON -SITE BY OTHERS -AND MUST MEET LOCAL CODES PERIMETER BLOCKING ON -SITE 48' O.C. MAX. DESIGN MEETS FBC AND A.SCE FOR 14OMPH (3 SEC. GUSTS) ALSO MEETS N1ND20NE III EXP. B LOADING FOR PARTIALLY ENCLOSED STRUCTURES RF. PG. 07-0050, 07-0051 20 �R OO EF ID PSF D.L N D S 01 REF. CALM - `� APPROVED BY I. HOST BEAM INSTALLATION 5 FOR ON -SITE STRUCTURE ATTACHMENT: _ -;-.-c:}iP!Q.;;�•, �l. 9 AIDE MAX NND ?ONE 2 OR 12.7MPH EXP. B SITES. _' ;' `:' 4 '• ON 16' WIDE MAX WO ZONE 3 OR 140UPH EXP. B SITES `' "^ f •:-': Jan 20,2( 2. MIN. BRACKET LOAD CAPACITY FOR WRTICAL TIE -DOWNS 5 AiNC. 24501 WIND ZONE 4 29601 WWND ZONE 3 • , / d 3. WALL FRAMING IS 2 X 6 SPF Ifi' O.C. ,��9�^•••F,`OF1�4.: 5•TA: OF •a`(``, CTIONMANUA D IRED SAFETY STANDARDS COXSTXUCEIOXGNO SAFELY STANDARDS CONSTRUCTION 4. 48' O.C. PERIMETER BLOCKING REQUIRED ON HOST BEAM SIDE OF HOUSE ; • • ,'.\•V��' sF,/S JACOBSEN HOMES NONCE: r1�({�y DESE9E"ICAIIONSAI101RZYSML-S` YA Y: D.M.T. DATE: 01-10-07 I V. LETTER DRAWING RILE: ATT. TO HOST BEAM MUTUAL PROMETMY, AND DDFMX A4L YAMAY OF AAm YAN.FA Wft P.O. BOX 368 Elm, R WCH YATFFNS ME MOOED DD TD( DRAWING NUMBER: SU-DI-DDOB SAFETY HM20R. FLORIDA 34695 PHONE (7271 726-1138 A mNl Rm 9 YII6DAS" ml BE RPf CpYtpNE IW 40ET D1W OOYIti 14 BLOCKING FOR TEMPORARY SET FLOOR SYSTEM MUST BE LEVEL SINGLE WIDE UNIT BLOCKING PIER MAIN -BEAM HEADER MAIN I -BEAM \ BLOCKING PIER �J MAIN [-BEAM /HITCH TEMPORARY BLOCKING IS REQUIRED ON HOMES LOCATED AT THE DEALERS LOT OR PARKED AT HOME SITE FOR ANY PERIOD OF TIME. BLOCKING PIERS ARE TO BE LOCATED UNDER MAIN I -BEAM AT THE REAR, AT THE HITCH, IN BACK OF AND IN THE FRONT OF AXLE AREA. MULTI —WIDE UNITS BLOCK EACH UNIT OF MULTI-VADE HOME IN SAME MANNER MAIN I -BEAM HEADER AXLE MAIN I -BEAM BLOCKING PIER BLOCKING PIER MAIN I -BEAM ———— MATE LINE — —_ AXLE IV,y1 MAIN I -BEAM BLOCKING PIER rBLOCKING PIER `I MAIN I -BEAM FLUON SYSILM MU51 BL LLVLL MAIN I- AM HEADER TEMPORARY BLOCKING IS REQUIRED ON HOMES LOCATED AT THE DEALERS LOT OR PARKED AT HOME SITE FOR ANY PERIOD OF TIME. BLOCKING PIERS ARE TO BE LOCATED UNDER MAIN I -BEAM AT THE REAR, AT THE HITCH, IN BACK OF AND IN THE FRONT OF AXLE AREA. 15'-4" �184"1 WIDTH UNIT REQUIRES PERIMETER BLOCKING 96' O.0 AT SIDEWALL AND MARRIA E WALL. ❑❑❑❑ JACOBSEN HOMES NOTICE: THESE SPE AND DRAWINGS �l'" °'' D.M.T. '^ 10-10-08 4 y ❑❑■❑ RARE & RFl EIAR MATERI4 PRACMY, AND �NFlDENIING MATERIALS OF JACDBSRE YMIIFACTURINC DRAWING TITLE: TEMP. BLOCKING ❑>�,❑ P.O. BOX INC. 60CH ME PRONDFD ID THE ❑❑❑❑ SAFETY HARBOR, 726-11 34695 FLORIDA PHONE (727) 726-1138 R SPEAL5 KEPTKUPIENT IDE TIN. AN SEMET5 AM Y157 M KEPT 0.YlDFIfILY AND SEDEi FltCY O11EAS DRAWING NUMBER: SU-Di-DOD9 15 16" X 16" PIER FOOTER SPACINGS* MAXIMUM I -BEAM PIER SPACING FLOOR MAXIMUM PIER SPACING (SOIL BEARING CAPACITY) WIDTH 1000 (PSF) 1500 (PSF) 2000 (PSF) 2500 (PSF) 3000 (PSF) 3500 (PSF) 120' WIDE FLOOR 39" 62' 86" 110" 134" 157" 144" V40E FLOOR 33" 53' 73" 93" 113" 133' 160" WOE FLOOR 30" 48" 66" 85' 103" 121"' 184" WIDE FLOOR 26" 42" 58" 74" 90" 107" MIN. PIER CAPACITY 1778 LBS. 2667 LBS. 3556 LEIS. 4444 LEIS. 5333 LBS. 6222 L85. NOTE: ALL UNIT WIDTHS INCLUDES A 6' OVERHANG ON BOTH SIDES MAXIMUM, 4" MINIMUM, AND/OR PER LOCAL CODE 1 REQUIREMENTS 4"TYP 17" OR B" T ��. T TYP 3MAX (TYP) Q Q _ NOMINAL 16" X 16' SQUARE PRECAST co 00 T CONCRETE FOOTING IT 16" MIN. EACH SIDE 4 X 8 X 8 SOLID 6 X 7 X 8 SOLID FOOTING CONC. BLOCKS CONC. BLOCKS TYPICAL PIER FOOTER TYPICAL PIER CONFIGURATIONS (THE CAPACITY OF THESE PIERS EXCEEDS MIN. REQUIRED) CONCRETE NOTES WINDZONE 111 1. ALL FOOTINGS CONCRETE TO HAVE fc = 3000 PSI MIN AT 28 DAYS; (110 MPH) ALL EXPOSURES 2. ALL SOLID CONCRETE BLOCKS TO HAVE Im' = 1500 PSI MIN; 20 PSF ROOF 3. CENTER ALL PIERS ON FOOTINGS 10 PSF D.L. REF. CALCS. `Aplpilllllll/IAA NOTES: E\` V I F!'i�4i DAPIA APPROVAL REFER TO OTHER DETAILS FOR ADDITIONAL PIER FOOTER SIZES AND G.STEgFO ! -; N0. APPROVED EY I. SPACINGS, Q 910334 •; 2. START I -BEAM PIER SPACING 1/2 THE ALLOWABLE SPACING FROM EACH END 7 �a� * - OF THE HOME AT EACH [-BEAM, AND MAXIMUM SPACING SHOYM IN THE CHART •. OF ? = N ABOVE FOR FULL LENGTH OF HOME -o STATE ' 9 '• P.� INC. 3. SEE OTHER DETAILS FOR PIER REQUIREMENTS AND MAAMUM OPENINGS / `l�'` ''�� ' A FEDERAL MANUFACTURED HOME At MATING LINE OF MULTIPLE WIDE HOMES. .N .• (Css ' GONSTRUCCjIQrypN�SPfTY fflAROS TyyN 4. SEE OTHER DETAILS FOR LIE -GOWN REQUIREMENTS. .1�Mpl(Gf N1j�j( V 1 JACOBSEN HOMES N011C THESE SPEORCArlmsAN DRAWN ARE CRx4RAl. PROPRIETARY, AND CMIDENTIA. WAM BY: M.T. OATS 2-8-99 REV. LETTER: D DRAWING TITLE: N BDx 368 MAMR19S OF JAMBSFN MAHUFACTURWC 16" x 16" PIER SPACING IVl P.O. SAFETY HARBOR, FLORIDA 34695 NIC SUw MWERIMS ARE PRONGED TO THE FEWW FOR SPECFIC H.WOSES Aw "T K AHO SEW moM 0THF16 DRA NG NUMBER: SU-0I-0020 L PHONE (727) 726-1138 IFRT COHRWRML 17 ALTERNATE MAIN BEAM PIERS (9 ITIr Itfr HOBO Cdimm uA6 o moom W 010 00 MT RENTED) WA FRO MARG V, . PRE PRE Db IT 1 4 IT SITE THICK I(SEE a 16) RER CAPPEDM P Do DR Y TREATED UTWR (SEE NOTE 16) �...... ® I ®FO a x �MDTEp a�iLS nC kqvy �00t5 SINGLE STACK BLOCK PIER �or,EJV&: ../�',iie (PERPENWaJEAR TO Ad) BE I No 45484 fA000 LBS 1Uu CAPACITY -SEE kOtE jl STATE rF o.`. voFR*I-DEAI)��a?�n�: �1210` ®tl VS TAEAar RE TRUDO OR e° 11� FOR e®®a HOGxr 40 A1�4(x� •) sD/ PIER CAPPED YM CONCRETE J 4' TRIX�QR 2 Y PRESSURE TREATED LL& (SEE NOTE AS) Ii Y er 1 16' CEW CE1L5 SOWY ONS _/ \1/ R N DOUBLE STACK BLOCK PIER 10,000 m CAPACITY (SEE NOTE 0 1112) 1f Y e Y I6" RQLo* CdICRETE mOIX IS sH* Hpl�Fk OfiSEi$ THE TOP TO THE EpINY 6 THE P6A E 110T EYCffD fit.. 6 Y r< Y IC HI OONDiTE BL= ARE sH* Ik OFTSETS FROM THE TOP 10 THE BOTt Or THE PER R NOT [YDSD Ilf. FLOOR WIDTH MAX. AXI U I -BEAM PIER SPACING (CONTROLLED BY PEER LOAD CAPACITIES) 48" O.C. 72" O.C. 96" O.C. 120" O.C. 144' SIDE FLOOR 2428 LBS 3488 LBS 4548 LBS 5608 LBS 16O' *DE BOOR 2661 LOS 3838 LBS 5014 LEIS, 6191 LBS I84' *DE FLOOR 2961 LBS 4280 LBS, 5615 In 6941 LBS. 1T u PIER LOADS INCLUUL WtIWI A7r nc" Ir ry tavl - Am. u; I— H••••. • •-.. "-.�...- -.-... _._ NOUNIT INCLUDES LHSIDES PS CAPACITIES BASED GN SOIBEARING P (CHECKPIER PADLOADSF) HI 20 PSF ROOF IO PST D.L. 1x911-01-o020 FoR PIER SPACING WHEN 0 G IS Y 15' PIER PADS, �1kN U*G IC Y le APPROVED BY PER PADS OTHER MAN O*ORElE OffY IJUSI DE DSTFD Alp CERDj'IED,TO EXCEED OR BE Revised [aEAl IN �h PER CAPACITY. Oct 1 7,2008 2, *EN USING PIER PADS THEY VLSI DE LISTED & CERTIFIED TO EXCEED OR EQ1AL Oli. PER CAPACITY. 3, START -BEAU. PIER SPAONG 24' FRoU EACH END OF THE HO ,AT EACH 1-BEAV A161 VAYM reoePn�nnr/uFnau/arol NVoMllr..� SPACING SH* N THE CHART ABOVE FOR TEAL LENGTH OF II(f,E. CONSTRUCTION AND WL IYSTMLAAD5 4, ANY PIER HI ABOVE 67* DUST BE DESIGI(ED BY A P.E. OR ARODTECI. 4 CAPSVISITBE SAFE LEN�GTTHE�AND I"tDM AS THE PIERS ON j 10 THEY TEST, 4 HARD 40 INLL LE4AD�iG VERTICALIf/AOR PR 2 OR 4 0 ND�INk SOLID CONCRETE ROCK UAY Norde BY: O,A, D TEI 2-8-99 REV. LETTER: JACOBSEN HOMES 1RSLSPEDFMATIOPSSlo"A P,O. BOX m � Wme" ks G n>vA LET. VAIN BEAM PIERS B NFd SAFETY HARBOR, FLORIDA 34695 1 IroLSRorc R(ULI ItDR G R,T4fONE (72» 716-I138 Mir A1PonEx SU-01-0021 (f0-08-�)10 Ll MINIMUM HOME SET HEIGHT FINISH GRADE NOTES: WHERE THE GRADE IS SLOPED, 25% OF THE LOWEST MEMBER OF THE MAIN FRAME MAY BE SET BELOW 18"; HOWEVER, TINDER NO CIRCUMSTANCES MAY THE BOTTOM OF THE I -BEAM BE SET BELOW 12" FROM THE FINISHED GRADE. ❑❑ JACOBSEN HOMES NOTICE: THESE SPECIFICATIONS AND DRAWNGS ARE ORIGINAL, PROPRIETARY, AND CONFIDENTIAL MATERIALS OF JACOBSEN MANUFACTURING FUIE1124aI P.O. BO% 368 INC. SUCH MATERIALS ARE PRONDEO TO THE DE SAFETY HARBOR, FLORIDA 34695 PHONE (727) 726-1138 REIPICNT FOR S OHC PURPOSES AND MUST NEPI CONFlDEN➢AL AND SECRET FROM OTHERS. 19 B.E.M. I 2-11-99 MIN, HOME SET HEIGHT SU-01-0022 16" X 16" PIER FOOTER SPACINGS* (MIN. 256 SQ.IN) MAXIMUM I -BEAM PIER SPACING FLOOR MAXIMUM PIER SPACING (SOIL BEARING CAPACITY) WIDTH 1000 (PSF) 1500 (PSF) 2000 (PSF) 2500 (PSF) 3000 (PSF) 3500 (PSF) 120" WIDE FLOOR•• 39" 62 1/2" 86 1/2" 110" SEE NOTE q4 SEE NOTE a4 144" WIDE FLOOR- 33" 53' 73 1/2" 93 1/2" 113 1/2" SEE NOTE #4 160" WIDE FLOOR-- 30" 48 112" 66 1/2" 85" 103" SEE NOTE pa 184" WIDE FLOOR-- 26 1/2" 1 42 112" 1 58 1/2" 74 1/2" 90 1/2" 107" MIN. PIER CAPACITY 1778 LBS 2667 LBS )556 LEIS 4444 LBS 5333 LBS 6222 LBS 18 1/2" X 18 1/2" PIER FOOTER SPACINGS* (MIN. 342 1/4 SQ.IN) MAXIMUM I -BEAM PIER SPACING FLOOR MAXIMUM PIER SPACING (SOIL BEARING CAPACITY) WIDTH 1000 (PSF) 1500 (PSF) 2000 (PSF) 2500 (PSF) 3000 (PSF) 3500 (PSF) 120" WIDE FLOOR- 54 1/2' 86' 117 1/2" SEE NOTE Q4 SEE NOTE q4 SEE NOTE #4 144" WIDE FLOOR• 46" 73" 100' SEE NOTE q4 SEE NOTE N4 SEE NOTE g4 160" WIDE FLOOR.. 42" 66 112" 90 1/2 115" SEE NOTE #4 SEE NOTE p4 184" WIDE FLOOR-- 37" 58 1/2" 79 1/2" 101" SEE NOTE X4 SEE NOTE a4 MIN. PIER CAPACITY 2377 LBS. 3565 LBS. 4753 LBS. 5942 LBS. 7130 LBS. 5319 LBS. NOTE: UNIT WIDTH$ WITH .. INCLUDES A 6" OVERHANG ON BOTH SIDES MAXIMUM. FOR TYPICAL PIERS SEE PAGE SU-01-0021 NOTES: 1. PRE -FABRICATED PIER PADS MAY BE USED AS AN ALTERNATE TO THE CONCRETE ENGINEER APPROVAL: y DAPIA APPROVAL: /g&f Cot:: /„ G '.),,, 43 -,r LC - (.�, FOOTINGS SPECIFIED IN THE JACOBSEN HOMES SET-UP MANUAL. J lL 2. THE PRE -FABRICATED PIER PADS ARE TO BE INSTALLED PER THE �.r '}F APPROVED BY MANUFACTURERS INSTALLATION INSTRUCTIONS AND MEET THE MINIMUM PIER CAPACITIES SHOWN ABOVE. , 4f 4"l C f f 'AEA, 5. ALL OTHER REOUIREMENTS ARE TO BE ADHERED TO AS SPECIFIED IN THE JACOBSEN HOMES INSTALLATION INSTRUCTIONS. I^ I�• 4. MAX. PIER SPACING 8' FOR UNITS WITH 8' I -BEAMS / 10 FOR UNITS WTH 10' OR 12'I-BEAMS (24' MAX. FROM ENDS).'' -rnwRl FEDERAL MANUFACTUREDHOME CTION AND SAFETY STANOARUS JACOBSEN HOMES NOTICE: THESE SPECIFICATIONS AND DRA'AVRDE ARE DRAWN BY: D.M.T. DATE: 09-22-01 REV. LETTER: DRAWING TITLE: PRE-FAB. 16' k 18 12 PIER PAD SPACING / w P.O. BOX 368 ORIGINAL PPOPERETARY, AND CGiIDENTAI MATERALS OF JACOBSEN MANUFACTURING _ SAFETY HARBOR, FLORIDA 34695 INC. SUCH MATERIALS ARE PRONGED TO ME RECANT FOR SPECK PURPOSES AND MST BE DRAWING NUMBER: PHONE (813) 726-1138 KEPT CON110011AI AND SECRET FROM OrKRS SU-01-0023 18" X 22" PIER FOOTER SPACINGS* (MIN. 396 SQ.IN) MAXIMUM I -BEAM PIER SPACING FLOOR MAXIMUM PIER SPACING (SOIL BEARING CAPACITY) WIDTH 1000 (PSF) 1500 (PSF) 2000 (PSF) 2500 (PSF) 3000 (PSF) 3500 (PSF) 120" WIDE FLOOR-- 63 1/2" 100 1/2" SEE NOTE p4 SEE NOTE q4 SEE NOTE p4 SEE NOTE #4 144" WIDE FLOOR,- 54" 85" 116 1/2" SEE NOTE X4 SEE NOTE b4 SEE NOTE p4 160" WADE FLOOR-- 49" 77 1/2" 105 1/2" SEE NOTE H4 SEE NOTE X4 SEE NOTE 84 184" WIDE FLOOR,- 43" 68' 193" 117 1/2' SEE NOTE pa SEE NOTE N4 MIN, PIER CAPACITY 2747 LBS 4121 LBS 5495 LBS 6868 LBS 8242 LBS 9616 LBS 20" X 20" PIER FOOTER SPACINGS* (MIN. 400 SQ.IN) MAXIMUM I -BEAM PIER SPACING FLOOR MAXIMUM PIER SPACING (SOIL BEARING CAPACITY) WIDTH 1000 (PSF) 1500 (PSF) 2000 (PSF) 2500 (PSF) 3000 (PSF) 3500 (PSF) 120" WIDE FLOOR- 64 1/2" 101 1/2" SEE NOTE N4 SEE NOTE A4 SEE NOTE p4 SEE NOTE q4 144" WIDE FLOOR-- 54 1/2' 86' 117 1/2" SEE NOTE q4 SEE NOTE N4 SEE NOTE q4 160" WIDE FLOOR.• 49 1/2" 78 1/2" 107" SEE NOTE #4 SEE NOTE #4 SEE NOTE Q4 184" WIDE FLOOR-- 43 1/2" 69" 94" 119" SEE NOTE N4 SEE NOTE N4 MIN. PIER CAPACITY 2778 LBS. 4167 LBS. 5556 LBS. 6944 LBS. 8333 LBS. 9722 LBS, NOTE: UNIT WIDTHS WITH •• INCLUDES A 6" OVERHANG ON BOTH SIDES MAXIMUM. FOR TYPICAL PIERS SEE PAGE SU-01-0021 TWIN�AP. /o NOTES; TO THE CONCRETE EN APPR'�� TyAy +% $ {. . yYF , Ayii DAPIA APPROVAL: 1 BE e fle, PG• I. PRE -FABRICATED PIER PADS MAY BE USED AS AN ALTERNATE SET-UP MANUAL. �% �Q• ,.G%gTrE�F,/j iY (¢� C•�. J FOOTINGS SPECIFIED IN THE JACOBSEN HOMES �� 1V0 2. THE PRE -FABRICATED PIER PADS ARE TO BE INSTALLED PER THE a ' 910334 •' PPROVED BY MANUFACTURERS INSTALLATION INSTRUCTIONS AND MEET THE MINIMUM PIER CAPACITIES SHOWN ABOVE. 3. ALL OTHER REQUIREMENTS ARE TO BE ADHERED TO AS SPECIFIED IN THE JACOBSEN g (` .o �j13kTE .'v = OCT HOMES INSTALLATION INSTRUCTIONS. ' FOR UNITS WTH 10OR . • .� •, p. ' e'11 INC. 4. MAX. PIER SPACING 8' FOR UNITS WITH 8' I -BEAMS / 10' yOAXN'.a'' �2 4 ` 12' I -BEAMS (24" MAX. FROM ENDS). EOERAL M11ANUfACTU IEO HOME JACOBSEN HOMES NOTICE: "I" FA45 THESE SPECM1CAiUTAR AND ORAWNCS ARE d BY: D.M.T. DATE: 09-22-01 REV. LETTER; DRAWING TIRE: PRE-fAB. 18' X 22' k 20' PIER PAD SPACING„ P.O. BOX 368 ORIGNAL PROPRIETMY, AND CCfiIDE'a", MATERIALS OF ACDDSEN MANUFACTURING AC. SIGN MATERIALS ARE PROMDED TO THE _ DRAWING NUMBER: SU-OI-OOZ4 SAFETY HARBOR, FLORIDA 34695 PHONE (813) 726-1138 REEAENT FOR SPECIFIC AAPoSfS NO MST DE IQPT co nDENnA. AND Maw mom OTHERS, 21 1 20 17 3/16" X 25 3/16" PIER FOOTER SPACINGS* (MIN. '432 7 /8 SQ. IN) MAXIMUM I -BEAM PIER SPACING MAXIMUM PIER SPACING (SOIL BEARING CAPACITY) p144"gwIDEFLOOR;-- 1000 (PSF) 1500 (PSF) 2000 (PSF) 2500 (PSF) 3000 (PSF) 3500 (PSF) FLOOR-- 70 1/2' 110 1/2" SEE NOTE p4 SEE NOTE p4 SEE NOTE p4 SEE NOTE p4 59 1/2" 93 1/2" SEE NOTE p4 SEE NOTE p4 SEE NOTE p4 SEE NOTE p4 160" WIDE FLOOR- 54" 85" it6" SEE NOTE p4 SEE NOTE p4 SEE NOTE p4 184" WIDE FLOOR•• 47 1/2' 75" 102" SEE NOTE p4 SEE NOTE p4 SEE NOTE p4 MIN. PIER CAPACITY 3004 LBS, 4507 LBS. 6009 LBS. 7511 LBS. 9013 LBS. 10,516 L85. 24" X 24" PIER FOOTER SPACINGS* (MIN 576 SQ.IN) . MAXIMUM I -BEAM PIER SPACING FLOOR MAXIMUM PIER SPACING (SOIL BEARING CAPACITY) WIDTH 1000 (PSF) 1500 (PSF) 2000 (PSF) 2500 (PSF) 3000 (PSF) 3500 (PSF) 120" WIDE FLOOR.. 95 1/2" SEE NOTE p4 SEE NOTE p4 SEE NOTE p4 SEE NOTE p4 SEE NOTE p4 144" WIDE FLOOR.. 81' SEE NOTE p4 SEE NOTE p4 SEE NOTE p4 SEE NOTE pa SEE NOTE pa 160" WIDE FLOOR.- 74' 115" SEE NOTE p4 SEE NOTE p4 SEE NOTE p4 SEE NOTE p4 184" WIDE FLOOR-- 65' 101" SEE NOTE pa SEE NOTE p4 SEE NOTE p4 SEE NOTE p4 MIN. PIER CAPACITY 4000 LBS 6000 LBS8000 LBS. 10,000 LBS. 12,000 LBS. 14,000 LBS. NOTE: UNIT WIDTHS WITH •. INCLUDES A 6" OVERHANG ON BOTH SIDES MAXIMUM. FOR TYPICAL PIERS SEE PAGE SU-01-0021 EN P OV• :• '7n-, 'A•r'• S: NOT .� P '�5TlE;r; •`'< PIER PADS MAY BE USED AS AN ALTERNATE TO THE CONCRETE V : • G C' ' T7 ': DAPIA APPROVAL 5&E CtI-P6. I. PRE -FABRICATED "• MANUAL, R� No, =fY- (4,0d- FOOTINGS SPECIFIED IN THE JACOBSEN HOMES SET-UP 910334 '•. `_ PPROVED BY 2. THE PREFABRICATED PIER PADS ARE TO BE INSTALLED PER THE MANUFACTURERS INSTALLATION INSTRUCTIONS AND MEET THE MINIMUM ao•+'� PIER CAPACITIES SHOWN ABOVE. �' R F3 _ .yam = EB OCR 1 1 LL1U 3. ALL OTHER REQUIREMENTS ARE i0 BE ADHERED TO AS SPECIFIED IN THE JACOBSEN 4 r 4„ , " HOMES INSTALLATION INSTRUCTIONS. 1;1-1 (� �1.." �•¢ INC. 4. MAX. PIER SPACING 8' FOR UNITS WITH 8' i-BEAMS / 10' FOR UNITS WITH 10' OR .... AS EDERA L NIANUFACTUREO HOME I?' I -BEAMS (24' MAX. FROM ENDS). • NOTICE: f TE: REV. LETTER: JACOBSEN HOMES THESE SPECIFICATION$ AND DRAWINGS ARE D.M.T. 09-22-01 ORIGINAL PROPRIETARY, AND CGWRDENTIAL DRAWING TITLE: MATERIALS OF JACOBSEN MANUFACIURINO PRE-FAB. 17 X FAHARBOR, 25 k 24" PIER PAD SPACING P.O. BOX 368 INC. WCH MATERIALS ARE FRONDED TO THE SAFETY FLORIDA 34695 RECPENT FOR 1PEnlc PURPOSES AND "I BE DRIVING NUMBER: FROM SU-OI-OO2S PHONE (81}) 726-1138 NEPT CONDOENTIAL ANO MORET OKRS, eo 23 26" X 26" PIER FOOTER SPACINGS* 26" X 26" PIER FOOTER SPACINGS* (MIN: 67(5 SQ.IN) MAXIMUM I -BEAM PIER SPACING FLOOR MAXIMUM PIER SPACING (SOIL BEARING CAPACITY) WIDTH 1000 (PSF) 1500 (PSF) 2000 (PSF) 2500 (PSF) 3000 (PSF) 3500 (PSF) E DE FLOOR-- WID 113 I/2" SEE NOTE p4 SEE NOTE p4 SEE NOTE p4 SEE NOTE pb SEE NOTE p4 1 a4" WIDE FLOOR­96 I/2' SEE NOTE p4 SEE NOTE pa SEE NOTE N4 SEE NOTE pa SEE NOTE p4 160' WIDE FLOOR-- 87 1/2" SEE NOTE p4 SEE NOTE p4 SEE NOTE p4 SEE NOTE p4 SEE NOTE p4 184" WIDE FLOOR-- 77" 119 1/2" SEE NOTE p4 SEE NOTE p4 SEE NOTE pa SEE NOTE p4 Y4694 MIN. PIER CAPACITA LBS. 7042 L85. 9389 185. 11,736 185. 14,083 L85. 16.431 NOTE: UNIT WIDTHS W1TH •• INCLUDES A 6" OVERHANG ON BOTH SIDES MAXIMUM. FOR TYPICAL PIERS SEE PAGE SU-01-0021 .^AT. •: •I„Pure,/O �? C� OP� IN R,A OV L It ¢;t` '`, DAPA APPROVAL -See- GACG' f6= 1. RE-FS�ABRICAIED PIER PADS WAY BE USED AS AN ALTERNATE 10 THE CONCRETE SET-UP MANUAL. VP,.•�\STrpF No.V. FOOTINGS SPECIFIED IN THE JACOBSEN HONES .'Q� C-rV- (�' 2. THE PRE -FABRICATED PIER PADS ARE TO BE INSTALLED PER THE MANUFACTURERS INSTALLATION INSTRUCTIONS AND MEET THE MINIMUM 910334 APPROVED BY PIER CAPACITIES SHOWN ABOVE. THE � Ei "•, � = E®q� 3. ALL OTHER REQUIREMENTS ARE TO BE ADHERED i0 AS SPECIFIED IN JACOBSEN HONES INSTALLATION INSTRUCTIONS. .p .rJ��iaT� •'�� Lg� OOCTa� 3. MAX. PIER SPACING 8' FOR UNITS W11H 8' I -BEAMS / 10' FOR UNITS PoTII 10' OR 4�A �P •. Ii� I�, I V 12' I -BEAMS (24' MAX, FROM ENDS). J e F11F I n f IF C c E: F JACOBSEN HOMES NOTiCLV THESE SPECIFICATIONS AND dRAWNGS ARE 'DRAWN BY: D.M.T. D,OgrySTRUG ION SAFE 09-22-01 Y N'r DRIVING TITLE: PRE -FIB. 26" PIER PAD SPACING P.O. BOX 368 ORIGINAL. PROPRIETARY, AND CONFIDENTIAL MATERIALS OF JACOBSEN MAxIFACNRING _ ,. SAFETY HARBOR, FLORIDA 3I695 Mc. $ua MATERIALS ARE PR04uED To THE R[FFENT FOR SPEOiC PURPOSES No MT BE AroT CONFIKOCNTML AND SECRET ma oTNERs. DRAWING NUMBER: SU-01-0026 PHONE (813) 726-1138 22 17" X 22" PIER FOOTER SPACINGS* (MIN. 374 SQ.INI MAXIMUM I -BEAM PIER SPACING NOTE: MAX. PIER SPACING NTH *** SEE NOTE #4 FLOOR MAXIMUM PIER SPACING (SOIL BEARING CAPACITY) WIDTH 1000 (PSF) 1500 (PSF) 2000 (PSF) 2500 (PSF) 3000 (PSF) 3500 (PSF) 120" WIDE FLOOR** 58' 89" 120"*** 120"*u 120"*** 120"*** 144' WIDE FLOOR** 50" 76' 103"s** 120"*** 120"*** 120"*** 160" WDE FLOOR** 45" 69 1/2- 94' 118"*** 120"*** 120"*** 184" WIDE FLOOR** 40' 81' 83" 1O4'*** 120"*** 120"*** MIN, PIER CAPACITY 2597 LETS. 3896 LEIS, 5794 LES, 6493 LEIS, 7792 LISS, 9090 L.BS. NOTE: UNIT WIDTHS WITH ** INCLUDES A 6' OVERHANG ON BOTH SIDES MAXIMUM, FOR TYPICAL PIERS SEE PAGE SU-01-0021 . PIER PAD (CORNERS MAY BE ROUNDED) 1MCAL PER FRAME I -BEAM ORIENTATION OF BLACK PLACED SYMETRICALLY ON PIER PAD PG. REF.®®®0�0 e`o C SU 19Co NOTES: a DAPS APPROVAL 1. PRE -FABRICATED PIERS MAY HE USED AS AN ALTERNATE TO THE OONCRE SET-UP MANUAL ( SPECIFIED IN THE JACOBSEN HONES ®-® m APPROVED BY 2 THE PRE -FABRICATED PIER PADS ARE TO BE INSTALLED PER THE `s MANUFACTURER'S INSTALLATION INSTRUCTIONS AND MEET THE MINIMUM S l, f' ,` s�°`. ^ o� e Dec 04,2009 PIER CAPACITIES SHOWN ABOVE ®e'n�°°• O •:C•° 3. ALL OTHER REQUIREMENTS ARE TO BE ADHERED TO AS SPECIFIED IN TIME JACOBSEN a®S ° ;, C'T °° ®A�Cts/OIV�'11 "otiw runuranunEo none a�nsmurnox uosutrc sraoauos HOMES INSTALLATION INSIRUCBONS °L°° 4. MAX. PIER SPACING W FOR UNITS WITH 87 F-BEAMS / 10' FOR UNITS W 10' OR pBJBBAB0 ERB°A%%% 12' I -BEAUS (24' MAX FROM ENDS -UK 1/2 THE MAX PIER SPACING IF THE PIER SPACING IS LESS THAN 48' O.G). JACOBSEN HOMES NOTICE THESE 6PEO"CATIOS Alm DRAWINGS ARE DRAWN BY: M.T. DATE: 11-23-09 REV LETTER: DRAWING TITLE: 17 X 22" PIER SPACING P.O. BOX 368 OIRGOW PROHTETMY, AID CONRDEHBN. WTEAIALS OF JACOBSEN MANUFACNRINC SAFETY HARBOR, FLORIDA 34695 INC Alai MATERIALS ARE PROVIDED TO THE RECRUIT FOR MnG KOM AMD MIST BE HEW CONn9FN11AL AND sETRET FROM OTI= DRAWING NUMBER: SU-01-0027 PHONE (813) 726-1138 24 PIER FOOTER SIZING CHART FOR MARRIAGE WALL OPENINGS Q (FOR SIDEWALL OPENINGS SEE NOTE ( ) LOAD SPANS Q SOIL BEARING CAPACITY PSF 8'-12' 12'-16' 16'-20' 20'-24' 24'-28' 28'-32' w C] 1000 390 sq. in. 494 sq. in. 511 sq. in. 701 sq. in. 805 sq, in. 908 sq. in. 1500 260 sq. in. 329 sq. in. 398 sq. in. 467 sq. in. 536 sq. in. 606 sq. in. 2000 195 sq. in. 247 sq. in. 299 sq. in. 351 sq. in. 402 sq. in. 454 sq. in. CV 2500 156 sq. in. 197 sq. in. 239 sq. in. 280 sq. in. 322 sq. in. 363 sq. in. MIN. PIER CAP. 27081bs. 34281lbs . 41481bs. 48681bs. 55881bs. 1 63081bs. LOAD SPANS w SOIL BEARING CAPACITY PSF 8'-12' 12'-16' 16'-20' 20'-24' 24'-28' 28'-32' q 1000 409 sq. in. 519 sq. in. 628 sq. in. 737 sq. in. 847 sq. in. 956 sq. in. `r 1500 273 sq. in. 346 sq. in. 419 sq. in. 492 sq. in. 565 sq. in. 638 sq. in. 2000 205 sq. in. 259 sq. in. 314 sq. in. 369 sq. in. 423 sq. in. 478 sq. in in 2500 164 sq. in. 207 sq. in. 251 sq. in. 295 sq. in. 339 sq. in. 383 sq. in a MIN. PIER CAP. 2841 lbs. 3601 lbs. 4361 lbs. 5121 lbs. 5881 lbs. 6641 Ibs. LOAD SPANS Q w SOIL BEARING CAPACITY PSF 8'-12' 12'-16' 16'-20' 20'-24' 24'-28' 28'-32' q 1000 428 sq. in. 544 sq. in. 659 sq. in. 774 sq. in. 889 sq. in. 1004 sq. in. 1500 286 sq. in. 362 sq. in 439 sq. in. 516 sq. in. 593 sq. in. 670 sq. in. 2000 214 sq. in. 272 sq. in. 329 sq. in. 387 sq. in. 445 sq. in. 502 sq. in. co 2500 171 s in. q� 217 s in. q� 264 s in. q� 310 s in. q� 356 s . in. 9 402 s in. q� MIN. PIER CAP. 2975IDS 3775IDS f4575lbs 5375Ibs 6175lbs 6975lbs LOAD SPANS w SOIL, BEARING CAPACITY PSF B'-12' 12'-16' 16'-20' 20'-24' 24'-28' 28'-32' Q 1000 486 sq. in. 618 sq. in. 751 sq. in. 883 sq. in. 1016 sq. in. 1148 sq. in. ao 1500 324 sq. in. 412 sq. in. 501 sq, in. 589 sq. in. 677 sq, in. 766 sq. in. 2000 243 sq. in. 309 sq. in. 375 sq. in. 442 sq. in. 508 sq. in. 574 sq. in. 0 2500 194 sq. in. 247 sq. in. 300 sq. in. 353 sq. in. 406 sq. in. 459 sq. in. Co MIN. PIER CAP. 3375lbs 4295IDS 52151bs 6t351bs 70551bs 79751bs WINDZONE III (110 MPH) ALL EXPOSUR 20 PSF ROOF 10 PSF D.L. NOTES: W. CALLS. _ -- - SEE DETAIL 'B'. PAGE SU-01-0001 FOR BLOCKING AND ANCHORING OF MARRIAGE WALL 111111 49 INCHES, OPENINGS E ER MAN(D. ENgHEQ(i� PI`0„A ST/j.... � DAPIA APPROVAL 2 UNDER O OO 3 (1) , AND O TAHLE 1 PACE SU-01-0040. �� O FOR ALL UNIT AIDTHA USE 1T7 mtn PIER FOOMR UNDER 9DEWAL OPENINGS THAT j (�Q;.•'G�ST Eq'•. FQ APPROVED BY ARE 49 INCHES TO 96 INCHES WIDE. FOR OPENINGS THAT ARE 96 INCHES TO 144 INCHES, USE 242 *V/ PIER TOOTER UNDER SIDEWALL OPENINGS. '•, L .'Q� No. `* •: (MIN. T000 PSF SOIL BEAPING REO'D) z 910934 ; IO FOR PROPER LOAD SPANS, SEE SU-03-000I. (LOAD SPANS' ARE aEARSPANS; PIER �*� �` � PINC. SPEdFICA80NS ABOVE ASSUME CIEARSPAN OCCURS ON WE SIDE OF PIER ONLY - IF CLEIRSPAN OCCURS ON BOTH SIDES, ADD VALUES LISTED ABOVE FOR -0 ',LTATE OF :•� = EACH CLEARSPAN) OS CHECK WITH LOCAL lURISOlCRON TO DETERMINE THE SOIL VALUE ON YW0. SITE CR HAVE A SOIL BEARING TEST PERFORMED YWR % 90'W �'i'`D FEDERAL MANUFACIURHINOIAE CN SCL TO DETERMINE THE VALUE. CONSTFUIIONAID GAMEY STANDARDS 7 MAR 0 1 1999 FE=JACOBSEN HOMES NOTICE: F IN,%sPEanum",m,DRAYmcs F BBA : B.E.M. DATE: 2-6-99 REV, LETTER: . P.O. BOX 368 ORIGINAL PROPRIETARY, AND COMDENRAL MATERIALS OF JACOBSEN MAHUFALIURWC DRAWING TITLE- PIER FOOTER SIZING CHART MARR. WALL OPENINGS SAFETY HARBOR, FLORIDA 34695 KOPER CH a 94�m sARE NuMDlismu DRAWWGNUMBER:OR PHONE (727) 726-1138 NEAT CCxnDF an AND YaET fRw OTTERS SU-01—" 30 25 TABLE I PIER FOOTER SIZING AND PIER SPACING CHART (SEE NOTES BELOW) 12-WIDE WIDTH MAXIMUM Qt O5 PIER SPACING SOIL BEARING PSF CAPACITY Q2 © REQUIRED PIER FOOTER AREA, SQ. IN. 3'-0" MAXIMUM FROM EACH END 1000 655 AND 8'-0" ON CENTER MAXIMUM 1500 437 (MINIMUM PIER CAPACITY 4548#) 2000 327 2500 262 4'-0" MAXIMUM FROM EACH END 1000 808 AND 10'-0* ON CENTER MAXIMUM 1500 538 (MINIMUM PIER CAPACITY 5608#) 2000 404 2500 323 13'-4"-WIDE WIDTH MAXIMUM 0 (5 PIER SPACING SOIL BEARING PSF CAPACITY O2 © REQUIRED PIER FOOTER AREA, SQ. IN. 3'-0" MAXIMUM FROM EACH END 1000 716 AND 8'-0" ON CENTER MAXIMUM 1500 478 (MINIMUM PIER CAPACITY 5014#) 2000 358 2500 287 4'-0" MAXIMUM FROM EACH END 1000 884 AND 10'-O" ON CENTER MAXIMUM 1500 590 (MINIMUM PIER CAPACITY 6191#) 2000 442 2500 354 15'-4'•-WIDE WIDTH MAXIMUM (S PIER SPACING SOIL BEARING PSF CAPACITY O2 © REQUIRED PIER FOOTER AREA, SQ. IN. 3'-0" MAXIMUM FROM EACH END 1000 807 AND 8'-0" ON CENTER MAXIMUM 1500 539 (MINIMUM PIER CAPACITY 5615#) 2000 404 2500 323 4'-0" MAXIMUM FROM EACH END 1000 1000 AND 10'-0" ON CENTER MAXIMUM 1500 666 (MINIMUM PIER CAPACITY 6941#) 2000 500 2500 400 ALL ZONES ALL EXPOSURES 20 PSF ROOF 10 PSF D.L. NOTES: -.. k,.GWA-9,T01- 9F, 02- Qt ON MULTIPLE SECTION HOUSES, CHECK EACH SECTION INDIVIDUALLY. Q2 UNDISTURBED SOIL OR 90% COMPACTION FOR FILL. ENIX`E\fRYy ROVAS TIC Lv� � DAPIA APPROVAL Q3 ALL FOOTERS TO BE BELOW FROST LINE. �PQ.•GA,STEq •�C �4i APPROVED BY ® MORE THAN ONE PIER MAY BE USED TO ACHIEVE THE MINIMUM - ;•Q�' .: SQUARE INCHES REQUIRED. 910334 IN QS ALL UNIT WIDTHS TO INCLUDE 6" SIDE OVERHANG ONE SIDE OR ONE 3' T �•� PINC. OVERHANG ON EACH SIDE MAXIMUM. AO% ,rAT �F : W -' © CHECK WITH LOCAL JURISDICTION TO DETERMINE THE SOIL VALUE ON YOUR SITE OR HAVE A SOIL BEARING TEST PERFORMED ON YOUR ALA FEDERAL MANUFACTURED HOME CONSTRUCTION AND SAFETY STANDARDS SOIL TO DETERMINE THE VALUE. • _•/,C> MAR 0 1 1999 NUTIuu- A Wif 1"1.."' -.. M.T. 1 2-8-99 JACOBSEN HOMES THESE SPECIFICATIONS AND DRAWINGS ARE ORIGINAL. PROPRIETARY, AND CONFIDENOAL DRAMWO TITLE: P.O. BOX 368 MATERIALS OF JACOBSEN MANUFA.CIURWO PIER FOOTER SPECS CHART a OIL' SUO MATERIALS ME PROMOEO TO THE SAFETY HARBOR, FLORIDA 34695 I¢wENT FOR SKaFIC RwOSFS AND JIM 9E DNAWMG NUMBER, PHONE (727) 726-1138 WT CONFOCNTUA MO SEOM FROM OTEI¢ SU-01-0040 MOBILE HOME SET-UP DIM. 'ADIM. 'B' COLUMN #1 `COLUMN #2 COLUMN #3 COLUMN SUPPORT SPANS TO PROPERLY SIZE PIERS LOCATED AT RIDGE BEAM SUPPORT COLUMNS, SURVEY THE ARRANGEMENT OF THE ROOMS IN THE MOBILE HOME TO LOCATE THE OPENINGS ALONG THE MARRIAGE WALL OF THE HOME. MEASURE EACH OPENING IN THE MARRIAGE WALL PAYING ATTENTION PARTICULARLY TO OPENINGS GREATER THAN 4 FEET WIDE. IN THE EXAMPLE ABOVE TO DETERMINE THE SPAN FOR COLUMN #1 SIMPLY USE DIMENSION 'A'. TO DETERMINE THE SPAN FOR COLUMN #2 ADD DIMENSION 'A' AND DIMENSION 'B' TOGETHER. THE SPAN FOR COLUMN #3 CAN BE DETERMINED THE SAME WAY AS COLUMN #1 SIMPLY USE DIMENSION 'B'. ONCE THE COLUMN SPANS HAVE BEEN DETERMINED, FIND THE CORRESPONDING PIER FOOTING SIZE IN THE CHART (SU-01-0030). ❑❑❑❑ ❑❑■❑ORIGNAL JACOBSEN HOMES NOTICE: THESE SPECIFICATO AND ORANTNGS ARE PROPRIETARY, AND CDNFIDEN➢AL MATERIALS OF JACOBSEN MANUFACTURING ^^ �' S.A. 6-6-94 1. DRAWING TITLE' COLUMN SUPPORT SPANS ❑„❑ P.O. BOX 368 INC. SUCH MATERIALS ARE PROVIDED TO THE ❑❑❑❑ DRAWING NUMBER: SU-03-0001 SAFETY HARBOR, FLORIDA 34695 PHONE (727) 726-1138. RECIPENT FOR SPECIFIC PURPOSES AND MUST BE XEPT CONFIDENTIAL AND SECRET FROM OTHERS. 26 27 SET UP NOTES (CLOSE UP) YOUR NoNs Is EQUIPPED WITH A FACTORY INSTALLED HATE LINN OASKNT. THE MATE LINE GASKET MUST BE INSPECTED BEFORE BRINGING THE HOME SECTIONS TOGETHER —IF THE GASKET IS DAMAGED, IT MAY BE REPAIRED NTH A FABRIC TYPE TAPE, AND IF DISLODGED, IT MUST BE REATTACHED. THESE ARE (3) SUGGESTED (NOT REQUIRED) ITEMS TO HELP ELIMINATE AIR INFILTRATION, 1. FABRIC TYPE TAPE ADHERED TO BOTH SECTIONS BEFORE APPLYING ON —SITE FINISH MATERIALS. 2. THERMO—PLY STRIPS OR EQUIVALENT (2" WIDE MIN.) FASTENED TO BOTH SECTIONS 1NTH NAILS OR STAPLES BEFORE APPLYING EXTERIOR FINISH MATERIALS. (NOTE: THE ROOF IS MATERIAL AND APPLICATION SPECIFIC.) 3. SMALLER GAPS APPROX. 1/4" WIDE MAY BE SEALED WITH A BEAD OF LATEX CAULK. (NOTE: A FOAM SEALANT MAY BE USED IN LIEU OF A LATEX CAULK.) BEFORE SETTING MULTIPLE WIDE UNITS, THE CLOSE—UP PLASTIC SHIPPING MATERIAL MUST BE REMOVED FROM ALL EXTERIOR WALLS OF ALL SECTIONS. THE SHIPPING PLASTIC MAY BE LEFT IN PLACE ON ALL MATING OR MARRIAGE WALLS OF EACH SECTION, BUT THE PANEL STRIPPING MATERIAL SECURING THE CLOSE—UP SHIPPING PLASTIC MUST BE REMOVED TO ALLOW THE MULTIPLE WIDE SECTIONS TO BE BROUGHT TOGETHER WITH MINIMUM GAPPING BETWEEN THE SECTIONS. THE SHIPPING PLASTIC IS TO BE REMOVING SHIPPING STRIPS). AFTER THE SECTIONS ARE SET TOGETHER THE CLOSE—UP PLASTIC, IF LEFT ON THE MARRIAGE WALLS, IS TO BE CUT OUT AT ALL OPENINGS TO THE OTHER SECTIONS. WHEN THE HOME'S RETURN AIR GRILLE IS LOCATED IN THE MARRIAGE WALL, THE FRAMING IS TO BE SEALED WITH LATEX CAULK OR FOAM SEALANT. AFTER REMOVAL OF THE GALVANIZED WIND DEFLECTOR(S) LOCATED ON THE ROOF AT THE HITCH END OF EACH SECTION OF THE HOME, SEAL ALL FASTENER PENETRATIONS OF THE ROOF SHINGLES WITH A ROOFING CEMENT OR OTHER SUITABLE MATERIAL. THE GALVANIZED WIND DEFLECTOR IS TO BE USED FOR THE ROOF CLOSE—UP, SEE AD—FA-0025 (AD—FA-0026 FOR TRIPLE WIDES). NOTE: BEFORE INSTALLING A CEILING FAN, INSTALL A 4 CU. IN. MINIMUM BOX EXTENSION. (CHECK FACTORY INSTALLED CEILING BOX FOR LABELING INDICATING SUITABLE FOR DIRECT ATTACHMENT OF CEILING FAN FIXTURE —IF NOT LABELED AS BEING SUITABLE, YOU MUST INSTALL A HOOK TYPE CEILING FAN —INSTALL HOOK THROUGH BOX INTO LUMBER BACKER BEHIND FAN BOX.) THE SAFETY CHAIN FOR ALL EXTERIOR OUTSWING DOORS SHALL BE INCLUDED IN THE SET—UP KIT. THE SAFETY CHAIN SHALL BE INSTALLED WHEN THE HOME IS SET—UP. INSTALL THE SAFETY CHAIN PER THE MANUFACTURERS SPECIFICATIONS INCLUDED WITH THE SAFETY CHAIN HARDWARE. FASTEN ALL EXTERIOR SIDING TRIM WITH 7/16" X 1" x 16 GA. STAPLES (OR EQUIVALENT) 6" O.C. MAXIMUM THROUGH SHEATHING INTO WALL OR FLOOR FRAMING. (UNDER HOME VENTILATION) WHEN ENCLOSING THE SPACE FROM THE BOTTOM OF YOUR HOME TO THE GROUND (SKIRTING, FOUNDATION WALLS, OR OTHER METHODS) THE AMOUNT OF VENTILATION REQUIRED IS TO BE DONE TO THE LOCAL CODES AND INSPECTED BY THE AUTHORITIES HAVING JURIDICTION. JACOBSEN HOMES NOTICE: T� �E aCrwxcs ARE ROPREEAR , AN aPoa+u. PRCPRECOBSE AND FACT RING YA90 NIDED T P.O. BOX THE ARE m THE INC. 91CN AD RIALS AIM R SAFETY FLORIDA CIPC OW AND R SIPENS FOR HONER(OR,) 726-138 IWr mR AND FROM OND THERS 28 M.T. IDATE 12-22-94 REV. UETU: A �12-0 SET UP NOTES SU-05-0001 EXTERIOR ROOFING CLOSE-UP RIDGE SHINGLES OR TABS CUT FROM THREE -TAB SHINGLES FURNISHED IN THE SET-UP MATERIALS APPLIED OVER COMPLETED SHINGLE ROOFING (INSTALL RIDGE SHINLGES PER ♦♦ MANUFACTUERS INSTALLATION INSTRUCTIONS.) ♦ I ♦♦ I I ♦I I♦ I I I I I i — COMPLETE SHINGLE ROOFING BY INSERTING FINISHING COURSE(S) OF SHINGLES TO EXISTING SHINGLES INSTALLED AT THE FACTORY. LIFT THE UPPER ROW OF SHINGLES AT THE TABS TO INSERT FINAL COURSE OF SHINGLES AND FOLLOW THE MANUFACTURERS WRITTEN INSTALLATION INSTRUCTIONS FOR FASTENING. (THIS APPLICATION FOR TRIPPLE WIDES ONLY) NOTES: 1. RIDGE SHINGLES ARE FACTORY APPLIED ON TRIPPLE WIDE HOMES, AND MUST BE APPLIED DURING SET-UP FOR DOUBLE WIDE HOMES. ❑❑❑❑ JACOBSEN HOMES NOTICE. THESE AND DRATINDARE ❑❑■❑ PROMEDNS ORIGINAL PROPRIETARY, AND CONBDENTAL ❑„❑ - P.O. BOX 368 MATERIALS JACNN INC. WCH ATRIAS ME PR04DED TO NE ❑❑❑❑ SAFEHARBOR,FLORIDA 4695 RECIPIENT FOR SPECIRY� AND OIHEHS PHONE (77) 72-1138 REPTCONDWO& SECRET FROM -COMPLETE SHINGLE ROOF BY ADDING FINISHING COURSE(S) TO SHINGLES INSTALLED IN THE FACTORY. ALLOW TOP END OF TOP ROW OF SHINGLES TO EXTEND ACROSS RIDGE ONTO OPPOSING SECTION OF MULTIPLE WIDES. (SEE SU-05-0011 FOR SHINGLE FASTENING REQUIREMENTS.) S.A. 6-6-94 TERIOR ROOFING CLOSE—UP OBER: SU-05-0010 SHINGLE INSTALLATION sx/ml II mpxa gaw-ry mrssP/ II wgreaz a�,w \0w DO M r N SEE PAGE RC-19-0002 NOTES: 1. SHINGLES FASTENED W/ MIN. 1" X 3/4" X 16 GA. STAPLES AS SHOWN IN THE SHINGLE FASTENING DETAIL. IF A STAPLE IS OVER —DRIVEN, PROPERLY INSTALL ANOTHER STAPLE RIGHT OR LEFT OF OVER —DRIVEN STAPLE AND SEAL OVER —DRIVEN STAPLE WITH ROOFING CEMENT. 2. WHEN METAL DRIP EDGE IS INSTALLED, IT IS NOT NECESSARY FOR SHINGLES TO OVERHANG THE RAKE (FRONT 8 REAR) EDGE OF THE ROOF. 3. SHINGLE UNDERLAYMENT FASTENED TO DECKING W/ MIN. 3/8" X 3/4" X 1B GA. STAPLES MIN. (TACKED DOWN UNTIL SHINGLES ARE APPLIED). 4. METAL DRIP EDGE FASTENED TO DECKING W/ MIN. 3/8" X 3/4" X 18 GA. STAPLES 12" O.C. MAXIMUM. 5. SHINGLE ROOF COVERINGS WHICH ARE SECURED W/ 6 FASTENERS PER SHINGLE THROUGH AN UNDERLAYMENT WHICH IS CEMENTED DOWN TO 3/8" STRUCTURAL RATED ROOF SHEATHING NEED NOT BE EVALUATED FOR DESIGN WIND PRESSURES. 30 FASTENING DETAIL NOTE: SHINGLES INSTALLED PER MANUFACTURERS INSTALLATION INSTRUCTIONS ONLY WHEN SPECIFIC APPLICATIONS ARE NOT COVERED WITHIN THIS MANUAL. ❑❑❑❑ JACOBSEN HOMES ❑❑a❑❑ P.O. BOX 368, 901 4U ST. NORTH SAFETY HARBOR, FLA. 34695 PHONE (813) 726-1138 SHINGLE INSTALLATION © 6-6-94 REVISIONS: I DATE: 12-21-94 EXTERIOR FINISH CLOSE-UP SOFFIT AND FASCIA APPLICATION DETAIL METAL DRIP EDGE _ 1 y SOFFIT MATERIAL t-- FASCIA MATERIAL LAP RECEIVER (J CHANNEL) NOTES: 1. ALL MATERIALS REQUIRED FOR ON SITE COMPLETION OF THE LAP SIDING APPLICATION IS SHIPPED INSIDE THE HOME WITH THE SET-UP KIT. 2. FIRST LOCATE AND SECURE THE SOFFIT MATERIAL TO EACH SECTION OF THE HOME WITH EITHER STAPLES, NAILS, OR SHEET METAL SCREWS 6" O.C. 3. NEXT LOCATE AND SECURE THE FASCIA MATERIAL IN THE SAME MANNER AS LISTED ABOVE FOR THE SOFFIT. 4. THEN COMPLETE THE APPLICATION OF BOTH THE METAL DRIP EDGE AND THE LAP SIDING RECEIVER, 5. AFTER ALL PARTS HAVE BEEN JOINED AT THE MATING EDGES OF EACH SECTION OF THE HOME, BEGIN WITH THE LAP SIDING APPLICATION. START THE LAP SIDING APPLICATION AT THE BOTTOM OF THE HOME AS SHOWN IN THE LAP SIDING APPLICATION DETAIL BELOW. ALL TRIM AROUND OPENINGS (ie. WINDOWS AND DOORS) IS COMPLETED BEFORE THE HOME IS SHIPPED. LEAVE AMPLE ROOM AT ALL TRIM FOR THE LAP SIDING TO EXPAND AND CONTRACT WITH TEMPERATURE CHANCES. FOR ANY ADDITIONAL INFORMATION REQUIRED SEE THE MANUFACTURERS INSTALLATION INSTRUCTIONS PLACED INSIDE THE SET-UP KIT SHIPPED WITH THE HOME. LAP SIDING FASTENING: 1. SECURE HORIZ. LAP SIDING W/ MIN. 7/16" X 1" X 16 GA. STAPLEf 0. C. MAXIMUM THROUGH SHEATHING INTO STUD. SECURE ALL EXTI TRIM W/ MIN. 7/16" x 5/8" x 16 GA. STAPLES AT 6" 0. C. MAXIN 2. WITH METAL LAP STAPLE CROWNS MAY BE EITHER PARALLEL OR PERPENDICULAR TO NAILING FLANGE WITH BOTH LEGS OF STAPLE PENETRATING THE NAILING FLANGE. 3. WITH VINYL SIDING STAPLE CROWNS TO BE PERPENDICULAR TO NAILING FLANGE WITH ONE LEG CENTERED IN SLOT AND OTHER LEG ON OUTSIDE OF NAILING FLANGE WITH APPROX. 1/32" SPACE BETWEEN STAPLE CROWN AND NAILING FLANGE. 4. ALL FASTENERS TO BE WEATHER RESISTANT. BOTTOM STARTER STRIP HOOK STARTEF. STARTER STRIP LAP SIDING APPLICATION DETAIL OO❑❑ JACOBSEN HOME S NOTICE: THESE AND DRA'MNG6 ARE ^^°^ SA � ' 12-22-94 „"...... ❑❑■❑ORIGINAL, L. PROCA➢DNS PRDPRIETARY, AND CONDDENML SEN JACOBSEN MATERIALS OF JACOBSEN MANUFACTURING DRAWING TITLE: EXTERIOR FINISH CLOSE-U ❑„❑ P.O. BOX 368 SAFETY HARBOR, FLORIOA 34695 INC, SUCH MOF PROMDMANUFA Tp THE REaHENT FOR � CRC POBPDSES AND,MDST K DRAWNG NUMBER: ❑❑❑❑ PHONE (727) 726-1138 KEPT CMflNNlk AND SEMT lld DTHERS SU-05-0020 31 MOBILE HOME SET-UP/CLOSE-UP SITE INSTALLED EXTERIOR SIDING APPLICATION SEE OTHER DETAILS (SU-05-0031 THRU 0034) FOR PLAN NEW DETAILS IDENTIFING AREAS REQUIRING EXTERIOR SIDING TO BE SITE INSTALLED. SEE SU-05-0020 FOR LAP SIDING FASTENING, AND SOFFIT AND FACIA APPLICATION. ALL AREAS WHERE THE EXTERIOR SIDING MATERIALS EXTEND ACROSS THE MATING LINE BETWEEN MULTIPLE VIDE UNITS ARE REQUIRED TO BE FINISHED ON SITE TO PREVENT A CONTINUOUS SEAM IN THE EXTERIOR SIDING LOCATED AT THE MATING LINES) OF THE HOME. ALL TRIM AND EXTERIOR SIDING MATERIALS ARE PROVIDED IN THE HOME SET—UP KIT FOR COMPLETION OF ALL EXTERIOR SIDING APPLICATIONS FOR THE HOME. THE STARTER STRIP FOR THE LAP SIDING APPLICATION IS INSTALLED AT THE FACTORY TO ENSURE STRAIGHT ALIGNED APPLICATION OF THE SIDING. ALL TRIM MATERIALS NOT REQUIRING FASTENING TO MORE THAN ONE SECTION OF MULTIPLE SECTION HOMES IS ALSO FACTORY INSTALLED TO ENSURE PROPER CLEARANCES AND AN ASSURED MATCH TO THE REMAINDER OF THE HOME. ALL TRIM MATERIALS SECURED TO MORE THAN ONE SECTION OF THE HOME ARE TO BE FASTENED TO THE WALL FRAMING MEMBERS WITH MIN. 7/16" X 5/8" X 16 GA. STAPLES OR 1" ROOFING NAILS 6" O.C. MAXIMUM. TAKE CARE IN LOCATING TRIM MATERIALS TO ENSURE PROPER ALIGNMENT WITH THE FACTORY INSTALLED MATERIALS. ALL FASTENERS USED MUST BE WEATHER RESISTANT TO INSURE DURIBIUTY. ENCLOSED WITH THE EXTERIOR SIDING MATERIALS ARE THE MANUFACTURERS INSTALLATION INSTRUCTIONS DETAILING THE RECOMENDED INSTALLATION PROCEDURES AND SPECIFICATIONS FOR THE TYPE OF SIDING BEING USED ON THE HOME. CAREFULLY EXAMINE THE MANUFACTURERS INSTALLATION INSTRUCTIONS BEFORE ANY ATTEMPT TO COMPLETE THE REQUIRED INSTALLATION OF THE EXTERIOR SIDING MATERIALS. SHOULD FOR ANY REASON THE MANUFACTURERS INSTALLATION INSTRUCTIONS BE LOST OR MISSING, CONTACT JACOBSEN HOMES AT 901 4th Street North Safety Harbor, Florida 34695 OR CALL (813) 726-1138 FOR REQUESTING THE INSTALLATION INSTRUCTIONS. SKIRTING MUST BE ATTACHED IN A MANNER SO THE VINYL WILL SLIDE (EXPAND AND CONTRACT). WHEN 6 MIL PLASTIC UNDER HOMES, THE VENTILATION OF THE CRAWL SPACE CAN BE REDUCED TO 1 SQUARE FEET OF VENTILATION - PER EVERY 1500 SQUARE FEET. ❑❑❑❑ JACOBSEN HOMES NOTICE: DRAWN BY: DATE: REV. LETTER: THESE SPECIFICATIONS AND DRAWINGS ARE O.A. 06-06-94 ❑❑;;❑ DRICINAI, PROPRIETARY. AND NUFACTNTAL DRANINC TITLE: P.O. BOX 368 1 IS OF JACORIALS ARE MAMDED MANUFACTURING INC.wC IENCN R SPECIFIC AREM AND To THE EXTERIOR SIDING APPLICATION SAFETY HARBOR, FLORIDA72-11 34695 RECIPIENT CONFIDENTIAL TIAL AN PLEEW AND MST S DRAWING NUMBER: ❑ PHONE (727) 726-1138 KEPI CCtlIDENBAl AND sEasT Fltdl DTIttRS. SU-05-0030 (09-30-08) 32 MOBILE HOME SET-UP/CLOSE-UP SITE INSTALLED EXTERIOR SIDING APPLICATION (FOR SLIP UNIT MULTIPLE WIDES) MATING LINE OF UNITS SITE INSTALLED EXTERIOR SIDING MATING LINE OF UNITS SITE INSTALLED INSII CORNER POST SITE INSTALLED EXTERIOR SIDING ❑❑❑❑ 7� JACOBSEN HOMES NOTICE: THESE SPEGfiCATDNSAND DRAWINGS ARE UNAWN S.A. 6-6-94 ❑❑■❑ PROPRIETARY, AND CONFINUFAC URINGNTAL ORIDNAI,MATERIALS MANUFACTURING DRAWING TITLE: ❑„❑ P.O. BOX 368 MATERIALS OF JACOBSEN E INC. SUCH MAIERIAlS ARE PREMED is THE EXT.SD.APPL. FOR SLIP UNIT ❑❑❑❑ SAFETY HARBOR, FLORIDA 34695 REaPiENT FOR sEanc PuRPDSES AND MUST BE DRAWING NUMBER: PHONE (727) 726-1138 KEPT CONRDENTAI AND SECRET FROM OTHERS. SU-05-0031 33 Z J �3 RM= �J" X iK ,,, Q3 MOBILE HOME SET-UP SHUTTER INSTALLATION: SHUTT RS ARE NORMALLY FASTENED BY SCREWING DIRECTLY THROUGH THE VINYL SIDING. THIS TENDS TO RESTRICT SIDE —TO —SIDE MOVEMENT OF THE VINYL SIDING PANELS. HOWEVER, SEVERAL THINGS CAN BE DONE TO ELIMINATE BUCKLING OR OIL CANNING OF THE VINYL SIDING IN THESE AREAS: A. WHEN PANELS RUN FROM WINDOW AREA TO A CORNER POST OR OR J—CHANNEL (OR ANY TYP. VINYL SIDING TRIM) AT THE OPPOSITE END, BE SURE TO LEAVE PROPER CLEARANCE IN THE 'POCKET" — THEN SIDING WILL EXPAND TOTALLY IN THAT DIRECTION. B. TWO SHUTTERS BETWEEN WINDOWS: THE PANELS THAT WILL BE RESTRICTED BY THE SHUTTER SCREWS SHOULD BE SHORTER LENGTHS (SEAM BETWEEN WINDOWS — NOT ONE CONTINUOUS PIECE OF VINYL) — SIMPLY OVERLAP TWO PANELS IN THIS AREA. PANELS WILL THEN EXPAND TOWARD THE OVERLAP JOINT (SEE DETAIL "A"). OR STAGGER THE SHUTTER SCREWS — INSTALL FIRST SHUTTER, TAKE NOTE OF WHICH PANELS ARE RESTRICTED BY THE SCREWS. THEN INSTALL THE OPPOSITE SHUTTER, POSITION THE SCREWS FOR THIS SHUTTER THROUGH PANELS EITHER ABOVE OR BELOW THE PANELS RESTRICTED BY THE SCREWS FROM THE FIRST SHUTTER. BY DOING THIS THE PANELS OF VINYL SIDING WILL BE ABLE TO EXPAND IN AT LEAST ONE DIRECTION, SO LONG AS PROPER CLEARANCE HAS BEEN MAINTAINED IN THE "POCKET" AREA OF THE CHANNEL. (SEE DETAIL "B°) DETAIL "B" DETAIL "A" ❑O❑❑ JACOBSEN HOMES NOTICE: AND DRAWNGS ARE THESE I, PROPRIETARY, AND CONFIDENTIAL CRIGNA❑❑■❑ POFJA MNAWN 6F: S.A. DATE: 6-5-94 REV. LETTER: pRAIWNG TITLE: ❑„❑ P.O. BOX 368 MATERIALS 08S MATERIALS OF MATERIALS INC. SUCH MasRuls ARE PRDNDED To THE ARE ROMDEDCTO INGTHE SHUTTER INSTALLATION ❑❑❑❑ SAFETY HARBOR, FLORIDA 34695 RECIPIENT FOR SPECIFIC PURPOSES AND MUST BE DRAWING NUMBER: PHONE (727) 726-1138 KEPT CONFIDENTIAL AND SECRET FROM DINERS. SU-05-0034 MOBILE HOME SET-UP THERE ARE TWO TYPES OF WIND THAT CAUSE DAMAGE: HORIZONTAL AND UPLIFT. YOUR HOME IS DESIGNED FOR THE HURRICANE ZONE (ZONE 111). IF YOU FOLLOW OUR RECOMMENDATIONS YOU WILL PROTECT YOUR HOME FROM BOTH TYPES OF WIND FORCES. IN TIEING DOWN YOUR HOME, YOU MUST USE MATERIALS OF ADEQUATE STRENGTH AND SPECIFICATIONS. ANCHORING EQUIPMENT— (LOAD RESISTANCE) ANCHORING EQUIPMENT SHALL BE CAPABLE OF RESISTING AN ALLOWABLE WORKING LOAD EQUAL TO OR EXCEEDING 3.150 POUNDS AND SHALL BE CAPABLE OF WITHSTANDING A 50 PERCENT OVERLOAD (4,725 POUNDS TOTAL) WITHOUT FAILURE OF THE ANCHORING EQUIPMENT. ANCHORING EQUIPMENT— (WEATHERIZATION) ANCHORING EQUIPMENT (STRAPS, ETC...) EXPOSED TO WEATHERING SHALL HAVE A RESISTANCE TO WEATHER DETERIORATION AT LEAST EQUIVALENT TO THAT PROVIDED BY A COATING OF ZINC ON STEEL OF NOT LESS THAN 0.30 OUNCES PER SQUARE FOOT OF SURFACE COATED, AND IN ACCORDANCE WITH THE FOLLOWING: SLIT OR CUT EDGES OF ZINC —COATED STEEL STRAPPING NEED NOT BE ZINC COATED. TIE —DOWN STRAPS SHALL BE TYPE 1, FINISH B. GRADE 1 STEEL STRAPPING, 1, 1/4 INCHES WIDE AND 0.035 INCHES IN THICKNESS. CERTIFIED BY A REGISTERED PROFESSIONAL ENGINEER OR ARCHITECT AS CONFORMING WITH ASTM STANDARD SPECIFICATION 03953-91, STANDARD SPECIFICATION FOR STRAPPING, FLAT STEEL, AND SEALS. ANCHORING NOTE: THERE IS A TENDENCY FOR THE TOP OF THE ANCHOR ROD TO DEFLECT AND MOVE OR "SLICE" THROUGH THE SOIL WHEN LOADED WITH THE FRAME TIE. THIS IS NOT DESIRABLE. SINCE IT PERMITS THE MOBILE HOME TO BE DISPLACED DOWNWIND AND TEND TO SLIDE OFF THE PIERS. TO MINIMIZE DEFLECTIONS. AUGER —TYPE AND OTHER ANCHORS USING STEEL RODS SHOULD BE PUT ON AT AN ANGLE SO THEY ARE MORE IN LINE WITH THE DIRECTION OF PULL. THIS CAN BEST BE ACCOMPLISHED BY INSTALLING THE ANCHORS PRIOR TO PLACEMENT OF THE MOBILE HOME ON THE LOT. IF VERTICAL ANCHORS ARE DESIRED. THE ANCHOR MUST BE LISTED FOR USE u<RTICALLY AT THE CAPACITY REQUIRED FOR THE STRAPPING BEING ATTACHED. APPROVED BY NJUL 1 3 �' A iNC, rtDe UM&NOcummw � m&mrpmww CAUTION: DO NOT PRETENSION TIE —DOWN STRAPS ON ONE SIDE OF THE HOME ONLY. IF TENSION IS NOT APPLIED TO TIE —DOWNS ALTERNATELY ON OPPOSITE SIDES, THE HOME MAY BE PULLED OFF -HE SUPPORTS. 6-6-94 SU-07-0001 36 37 TIE -DOWN STRAPS SEE ADDENDUM TO SET-UP MANUAL_ ON SPECIFIC TIE -DOWN INFORMATION, THE DETAILS IN THIS MANUAL ARE ONLY TYPICALS, SEE ADDENDUM FOR SPECIFICS. DANGER: DO NOT PRETENSION TIE -DOWN STRAPS ON ONE SIDE OF THE HOME ONLY. IF TENSION IS NOT APPLIED TO TIE -DOWNS ALTERNATELY ON OPPOSITE SIDES, THE HOME MAY BE PULLED OFF THE SUPPORTS. ❑❑❑❑ ❑❑■❑ JACOBSEN HOMES NOTICE: THESE SPECIFlCAPONS AND DRAN1NG5 ARE ORIGINAL, PROPRIETARY, AND CONFIDENTIAL DRAWN BY S.A. DATE: 7-20-94 REV. LEIhH DRAWNG TITLE: ❑„❑ P.O. BOX 368 MATERIALS OF JACOBSEN MANUFACTURING INC. SUCH MATERIALS ARE PRONOED TO ME TIE -DOWN STRAPS DRAWING NUMBER: ❑❑❑❑ SAFETY HARBOR, FLORIDA 34695 REOPIENT FOR EPEOM PURPOSES AND MUST BE PHONE (727) 726-1138 KEPT CONFIOEXDAL AND SECRET FROM OTHERS SU-07-0002 MOBILE HOME SET-UP/ELECTRICAL ELECTRICAL CONNECTIONS BETWEEN HOME SECTIONS NOTE: NO ELECTRICAL POWER SHOULD BE CONNECTED TO HOMES WHILE MAKING ELECTRICAL CONNECTIONS. ALL ELECTRICAL WORK SHOULD BE DONE BY A QUALIFIED ELECTRICIAN. MATERIAL SUPPLIED 1. APPROPORATE NUMBER OF JUNCTION BOXES TO MAKE 2 CONNECTIONS PER JUNCTION BOX. (SHIPPED LOOSE IN THE SET-UP KIT) 2. WIRE NUTS. 3. JUNCTION BOX COVERS. INSTRUCTIONS A. SECURE JUNCTION BOXES UNDER HOME. B. WIRES HAVE BEEN COLOR CODED; SIMPLY MATCH UP COLOR CO-ORDINATED WIRES WITHIN A JUNCTION BOX AND CONNECT WITH WIRE NUTS. C. PLACE COVERS OVER JUNCTION BOXES. OMITTED CEILING FIXTURES FIXTURES TO BE INSTALLED AT THESE LOCATIONS MUST BE A TWO WIRE FIXTURE WITH GROUND. INSTALL ALL FIXTURES BEFORE TURNING ON MAIN BREAKERS. NOTE: SEE BELOW FOR SERVICE CONDUCTOR SIZES GROUND (GREEN OR BARE) WIRE TO GROUND BAR HOT LEADS (RED & BLACK) CONNECTED TO MAIN BREAKER NEUTRAL (WHITE) WIRE TO NEUTRAL BUSS MINIMUM CONDUIT SIZES: � __ N_ CONDUIT DROP FROM HOME - EXTEND 1 1/2" MINIMUM - 150 AMP TO BELOW GROUND LEVEL OR SEE 2" MINIMUM - 200 AMP LOCAL CODES TYPICAL ELECTRICAL CONNECTIONS CROSS -OVER CONNECTIONS CROSS -OVER INFORMATION APPLIES TO MULTI -SECTION UNITS CROSS -OVER WIRES ARE COLOR -CODED SERVICE CONDUCTORS MAIN BREAKER HOT I NEUTRAL GROUND 160 2 NO. 1 NO. 1 N0. 8 200 2 NO. 2 0 I NO. 2 0 1N0. 8 NOTE: ABOVE SERVICE CONDUCTORS ARE FOR COPPER ONLY. FOR COPPER -CLAD ALUMINUM REFER TO LOCAL CODES ELECTRICAL PANEL LABEL THIS LABEL IS LOCATED ON OR NEAR THE ELECTRICAL PANEL THE MINIMUM SIZE JUNCTION BOX ATTACHED TO THE CONDUIT FOR SERVICE CONDUCTORS ARE: 9" X 9" X 4" - 150 AMP OR 12" X 12" X 4" - 200 AMP JACOBSEN HOMES P.O. BOX 368 SAFETY PHONER 813 726 113FLORIDA 8N595 � ) NOTICE: THESE SPECIFICADONSAND DRAWINGSARE ORICNAL PROPRIETARY, AND CONFlDEHNL MATERIALS OF JACOBSEN MANUFACTURING INC. SUCH MATERIALS ARE PRONGED TO THESET-UP/ELECTRICALHAIH KEPPPTT�CONRODFIAL �P � MOUBOR DRANK BY: B.C.K. DATE: 03-30-12 REV. LETTER: FF�� j-{ DRAWING TITLE: ORANING NUMBER: SU-0g-0001 38 39 ELECTRICAL CROSS -OVER & TESTING PROCEDURES L--MARRIAGE LINE I I NOTCHED MARRIAGE WALL PERIMETER JOISTS — .92" DEEP NOTCH MAX. ELECTRICAL WIRING FROM ONE SECTION TO BE HOOKED —UP IN JUNCTION BOX(S) ELECTRICAL JUNCTION BOX(S) FASTENED TO TRANSVERSE FLOOR JOIST. AFTER ALL ELECTRICAL WIRING CONNECTIONS ARE MADE, SYSTEM MUST BE INSPECTED AND TESTED. (FOR CONTINUITY TEST PROCEDURES SEE SU-09-0020) TESTING THE POLARITY OF THE ELECTRICAL SYSTEM WILL REQUIRE TEST EQUIPMENT CAPABLE OF DETERMING INCORRECT WIRING CONFIGURATIONS, AND ALSO SHOULD INCLUDE ADAPTERS FOR VARIOUS CONFIGURATIONS (POLARITY TESTER). USING THIS DEVICE ALL ELECTRICAL CONNECTIONS (INCLUDING OUTSIDE FIXTURES SUCH AS HEAT TAPE RECEPTACLE) ARE INDIVIDUAL TESTED TO ENSURE ALL CONNECTIONS HAVE BEEN PROPERLY MADE. A PIGTAIL CIRCUIT TESTER MAY BE USED AS AN ALTERNATE TEST METHOD FOR LIGHT FIXTURES. PIGTAIL TEST IS AS FOLLOWS: HOT IN BASE OF SOCKET TO GROUNDED FIXTURE CANOPY (LIGHT MUST LIGHT), NEUTRAL TO FIXTURE CANOPY (LIGHT MUST NOT LIGHT), AND A GROUND CHECK TO DETERMINE NO OPEN GROUND. FAILURE AT ANY FIXTURE REQUIRES REPAIR AND RETEST. NOTE: ALL GROUND LEADS ARE SECURED TOGETHER AND BONDED TO THE JUNCTION BOXES W/ THE LARGEST SIZE CONDUCTOR IN BOX. (ALL REQUIRED JUNCTION BOXES ARE SHIPPED LOOSE IN THE SET—UP KIT) NO ES: 1. ALL ELECTRICAL WIRING CONNECTIONS TO BE MADE INSIDE LISTED JUNCTION BOX(S) IN COMPLIANCE WITH N.E.C. — 2005 2. WIRING IN LISTED JUNCTION BOX(S) NOT TO EXCEED CAPACITY OF THE JUNCTION BOX(S) PER N.E.C. — 2005. 3. WIRING TO BE PROTECTED AND SECURED AT MARRIAGE WALL JOISTS WITH WIRE PROTECTOR PLATES INCLUDED IN SET—UP KIT. 4. ELECTRICAL CROSSOVER WIRING TO BE DONE ONLY BY QUALIFIED PERSONNEL. MATCHING IDENTIFIED CIRCUIT WIRING FROM EACH SECTION OF MULTIPLE WIDE HOMES. 5. AFTER WIRING CONNECTIONS HAVE BEEN MADE, REPLACE COVER ON JUNCTION BOX(S), AND REPAIR ANY CUTS OR VOIDS IN THE BOTTOM BOARD WITH DUCT TAPE. ❑� JACOBSEN HOMES P.O. BOX 368 SAFETY HARBOR, FLORIDA 34695 PHONE (813) 726-1138 NOTICE: THESE SPECIFICATIONS AND CRAVINGS ARE ORIGINAL PROPRIETARY, AND WNBDENRAL MATERIALS OF JACOBSEN MANUFACTURING NC SUCH MATERIALS ARE pgpypED TO HE OSE❑oo❑° IgQP�i c�wDtNnAL g SEpOW pMms DRAWN BY: D.M.T. DALE: OS-25-06 REV. LETTER: (09-29-08) DRAING TITLE: ELECTRICAL CROSS —OVER DRANWG NUMBER: SU-09-0010 40 MOBILE HOME SET-UP/ELECTRICAL I —BEAM WIRE FROM BREAKER BOX TO GROUNDING TERMINAL g8 BARE COPPER WIRE MINIMUM OUTRIGGER GROUNG WIRE MAY BE ATTATCHED TO ANY PART OF THE FRAME ASSEMBLY (NOT REO'D TO BE ® OUTRIGGER). ANY APPROVED GROUNDING TERMINAL SECURED TO FRAME TO INSURE PROPER GROUND (METAL TO METAL CONTACT INSURED BY USING A STAR WASHER BETWEEN OUTRIGGER AND TERMINAL), TYPICAL ELECTRICAL GROUND NOTE: ALL EXPOSED NONCURRENT CARRYING METAL PARTS THAT MAY BECOME ENERGIZED SHALL BE EFFECTIVELY BONDED TO THE GROUNDING TERMINAL OR ENCLOSURE OF THE DISTRIBUTION PANELBOARD. A BONDING CONDUCTOR SHALL BE CONNECTED BETWEEN EACH DISTRIBUTION PANELBOARD AND AN ACCESSIBLE TERMINAL ON THE CHASSIS. NO. 8 BARE COPPER-------'LAPPROVED GROUNDING TERMINAL BOND WIRE (MINIMUM) ATTACHED TO OUTRIGGER OR I —BEAM (TYPICAL EACH UNIT). TYPICAL ELECTRICAL BONDING GROUNDING AND CONTINUITY TEST THE GROUNDING CONTINUITY TEST MUST BE PERFORMED BEFORE THE FEEDER CONDUCTORS ARE CONNECTED. PERFORM THE FOLLOWING TEST AFTER ALL STRUCTURAL ASSEMBLY, METAL AND TRIM INSTALLATION IS FINISHED: A. CONNECT ONE CLIP OF A FLASHLIGHT CONTINUITY TESTER TO A CONVENIENT GROUND (METAL SKIN, WINDOW FRAME ON METAL SKINNED UNITS, FLOOR DUCT RISER, SCREW HEAD ON RECEPTACLE OR SWITCH PLATE, ETC.) AND TOUCH THE OTHER CLIP TO EACH LIGHT FIXTURE CANOPY (WHERE LIGHT IS MOUNTED TO CEILING OR WALL). I-!E CONTINUITY TESTER SHOULD LIGHT IF EACH FIXTURE IS PROPERLY GROUNDED. U. REPEAT THESE PROCEDURES FOR ALL DIRECT WIRED APPLIANCES AND FIXTURES. C. USING THE SAME PROCEDURES, CHECK THE CONTINUITY BETWEEN THE FOLLOWING: 1. BETWEEN METAL ROOF AND STEEL FRAME. 2. BETWEEN METAL SKIN AND STEEL FRAME. 3. BETWEEN STEEL FRAME AND GAS PIPING. D. ANY LOSS OF GROUNDING CONTINUITY FOUND IN THE ABOVE WILL REQUIRE INVESTIGATION, CORRECTION, AND RETESTING FOR CONTINUITY. ❑❑❑❑ ❑❑■❑ ❑("❑ JACOBSEN HOMES P.O. BOX 368 SAFETY HARBOR, FLORIDA 34695 PHONE (727) 726-1138 NOTICE: THESE SPEORCATIONS AND ORAWNCS ARE ORIGINAL, PROPRIETARY, AND CDNFIOENPAL MATERIALS OF JACOBSEN MANUFACTURING INC. SUCH MATERIALS ARE PROMDED TO THE REGPIENT FOR VEONC PURPOSES AND MAST BE KEPT CONFIDENTIAL AND 9MET FROM OTHERS DRAMNBY. S.A. DATE ; 6-6-94 DRAWNG PILE: TYPICAL ELECTRICAL GROUNC CRANING NUMBER: SD-09-0020 41 EXTERIOR LIGHT FIXTURE INSTALLATION BE SURE ELECTRICAL SERVICE IS DISCONNECTED BEFORE COMING IN CONTACT WITH ELECTRICAL CONDUCTORS WHITE (NEUTRAL) WIRING FROM FIXTURE AND BOX TWISTED TOGETHER AND SECURED WITH WIRE NUT EXTERIOR ELECTRICAL BOX BARE (GROUND) WIRING FROM FIXTURE AND BOX TWISTED TOGETHER AND SECURED WITH WIRE NUT - FIXTURE FLASHING RING (THIN WHITE FIBROUS RING) - BLACK (HOT) WIRING FROM FIXTURE AND BOX TWISTED TOGETHER AND SECURED WITH WIRE NUT - EXTERIOR LIGHT FIXTURE (LISTED FOR EXTERIOR USE) BEFORE ELECTRICAL SERVICE IS CONNECTED TO THE HOME, INSPECT THE EXTERIOR OF THE HOME AND LOCATE ALL THE EXTERIOR LIGHT LOCATIONS TO BE INSTALLED ON SITE. (ALL EXTERIOR LIGHT FIXTURES IN PORCH AND OTHER AREAS NOT ALONG THE EXTERIOR WALL AREAS OF THE HOME ARE INSTALLED AT THE FACTORY). THE EXTERIOR LIGHT LOCATIONS CAN BE IDENTIFIED AS EXTERIOR ELECTRICAL BOXES IN THE WALLS USUALLY LOCATED ADJACENT TO EXTERIOR DOORS THAT ARE COVERED WITH BLANK (SOLID) COVERS. TO INSTALL THE EXTERIOR LIGHT FIXTURES, REMOVE THE BLANK COVERS FROM THE ELECTRICAL BOXES AND FEED THE THREE WIRES (IDENTIFIED IN THE DETAIL ABOVE) THROUGH THE FIXTURE FLASHING RING BEFORE THE CONNECTIONS OF THE CONDUCTORS ARE MADE, THE FIXTURE FLASHING RINGS MUST EXTEND FROM THE OPENING OF THE ELECTRICAL BOX TO THE OUTERMOST EDGES OF THE EXTERIOR LIGHT FIXTURE (EXCESS AMOUNT OF THE FLASHING RING MAY BE TRIMMED OFF AFTER THE FIXTURE IS SECURED TO THE ELECTRICAL BOX). TO INSURE AGAINST THE POSSIBILITY OF AN ELECTRICAL SHOCK, ALL ELECTRICAL CONNECTIONS SHOULD BE DONE WITH THE ELECTRICAL SERVICE SHUT OFF TO THE HOME, THE WIRE NUTS REQUIRED FOR SECURING THE WIRES WILL BE FOUND INSIDE THE ELECTRICAL BOX FOR THE FIXTURE (THESE WIRE NUTS ARE INSTALLED AT THE FACTORY TO CAP THE CONDUCTORS IN THE ELECTRICAL BOX), THE FIXTURE FLASHING RING IS LOCATED IN THE SHIPPING KIT INSIDE THE HOME. ❑❑❑❑ JACOBSEN HOMES xOTLCE: THESE nnwN HT: S.A. oATe 6-6— 94 REV. LETTER ❑❑■❑ AND DRAWNGS ARE L PROPRIETARY. ORIGINAL, PflOPRIETARY, AND CONFIDENTIAL DRAVNNG TITLE' ❑„❑ P.O. BOX 368 MATERIALS OF JACOBSEN MANUFACTURING INC. SUCH MATERIALS ARE PRONDEO TO ME LIGHT FIXTURE INSTALLATION ❑❑❑❑ SAFETY HARBOR, FLORIDA 34695 RECIPIENT FOR SPECIFC PURPOSES AND Mug BE DRAWING NUMBER: PHONE (727) 726-1138 KEPT CONFIDENTIAL AND SECRET FROM OTHERS. SU-09-0030 1 42 MOBILE HOME SET-UP ELUMBING CONNECTIONS CHECK WATER AND DRAIN LINES FOR ANY CONNECTIONS THAT MAY HAVE COME LOOSE DURING SHIPMENT. SHOULD YOUR HOME NOT BE EQUIPPED WITH A MASTER SHUT—OFF VALVE, ONE MUST BE INSTALLED BETWEEN THE HOME AND THE WATER SUPPLY. THE WATER SUPPLY SYSTEM IS DESIGNED FOR A MAXIMUM INLET WATER PRESSURE OF 80 PSI. IF THE LOCAL WATER SUPPLY PRESSURE TO WHICH THE HOME IS BEING CONNECTED EXCEEDS 80 PSI, A PRESSURE REDUCING VALVE SHOULD BE INSTALLED TO LIMIT THE SUPPLY PRESSURE. WHEN HOMES ARE SET IN AREAS SUBJECT TO FREEZING THE EXPOSED WATER SUPPLY LINES MUST BE PROTECTED. AN ELECTRICAL RECEPTACLE IS LOCATED ON THE UNDERSIDE OF THE HOME NEAR THE WATER INLET, AND NEAR ANY CROSSOVER LOCATION WHERE THE WATER LINES ARE EXPOSED. THESE ELECTRICAL RECEPTACLES ARE FOR THE CONNECTION OF AN ELECTRICAL HEAT TAPE. HEAT TAPE USED MUST BE LISTED FOR USE WITH MOBILE HOMES. FOR MULTIPLE SECTION HOMES WITH PLUMBING IN MORE THAN ONE SECTION, LOCATE AND CONNECT THE WATER CROSSOVERS LOCATED UNDER THE FLOOR ALONG THE MARRIAGE LINE BETWEEN THE SECTIONS. TURN THE WATER SUPPLY ON AND CHECK FOR LEAKAGE. CAUTION, DO NOT TURN THE POWER ON TO THE WATER HEATER UNTIL THE TANK IS FULL OF WATER. CONNECT DRAIN DROP OUTS TO COMPLETE ALL FIXTURE DRAINS AND MAIN DRAIN. BE SURE ALL CONNECTIONS ARE MADE TO COMPLY WITH LOCAL PLUMBING CODES. GAS PIPING HOMES WITH GAS PIPING HAVE BEEN FACTORY TESTED FOR LEAKS, HOWEVER, BEFORE CONNECTING THE GAS SUPPLY TO THE SYSTEM ANOTHER PRESSURE TEST IS REQUIRED TO INSURE THAT THERE ARE NO LEAKS AFTER THE HOME HAS BEEN TRANSPORTED AND SET—UP. 1. CLOSE OFF ALL THE GAS APPLIANCE SHUT OFF VALVES. 2. ATTACH THE GAS TEST FITTING GAUGE. 3. PRESUREIZE THE SYSTEM UNTIL 3 PSI OF AIR PRESSURE IS REACHED. 4. PRESSURE MUST BE MAINTAINED FOR 10 MINUTES WITHOUT ANY INDICATED PRESSURE LOSS. CAUTION: DAMAGE MAY RESULT IF THE SYSTEM IS OVER PRESSUREIZED, THE GAS PIPING SUPPLY SYSTEM HAS BEEN DESIGNED FOR A MAXIMUM PRESSURE OF 14" WATER COLUMN (1/2 PSI) AND NOT LESS THAN 7" WATER COLUMN (1/4 PSI). GAS. THE GAS PIPING SYSTEM IS DESIGNED TO USE EITHER LIQUIFIED PETROLEUM GAS OR NATURAL BEFORE TURNING THE GAS ON 1. BE SURE THE APPLIANCES IN YOUR HOME ARE DESIGNED FOR THE TYPE OF GAS BEING CONNECTED. 2. WHERE APPLICABLE ON MULTIPLE WIDE HOMES, LOCATE "QUICK —DISCONNECT" AND CONNECT. THE "QUICK —DISCONNECT" IS LOCATED UNDER THE FLOOR AT THE MARRIAGE LINE. 3. MAKE SURE ALL CONNECTIONS ARE TIGHT, AND ALL APPLIANCES ARE TURNED OFF. 4. AFTER THE GAS HAS BEEN CONNECTED AND TURNED ON, MAKE SURE ALL THE PILOT LIGHTS ARE LIT. O❑:❑ JACOBSEN HOMES NOTICE: DRANK BY: DATE REV LETTER: THESE ORDINAL DCONFIDS ARE D.M.T. 3-22-95 0 P.O. BOX 368 SAFETY HARBOR, FLORIDA 34695 PROPFKTARTIONS , M PFIFJAOARY AND CONFIDENTIAL SENARE MmuFAROWDBB ED KNGTHE INCMATERIALS"OF MATERIALS GPI ARONDfD 10 THE DRAWING TITLE PLUMBIMS. CON. & GAS TEST /1 H PHONE (727) 726-1138 RE R SPECIES PUR � nu µD p DRAWING NUMBER: KEPTAT SEW F D7�IER5a. SU-11-0001 (09-29-08) PLUMBING TESTS WATER SUPPLY PIPING TEST ALL PIPING IN THE WATER DISTRIBUTION SYSTEM SHALL BE SUBJECTED TO A PRESSURE TEST. (MULTI — WIDE UNITS SEE SU-11-0020A FOR CROSS —OVER CONNECTION) PRIOR TO TESTING BE SURE ALL PLUMBING ARMUW THE EXCEPT LEVEL. ALLCLOSE ALL SHHUT—OFF VALVESSINNPIPNGSE AND SYSTEEMHOLD THE OAT ARE OPENED FULLY (EXCEPTIONS ARE DISHWASHER AND ICE —MAKER SHUT—OFF VALVE WHICH WILL REMAIN CLOSED) TAKE THE HOT AND COLD SUPPLY LINES AT WATER HEATER AND (FOR TEST PROCEDURE ONLY) CONNECT THEM TOGETHER. OR IF YOU CHOOSE YOU MAY TEST HOT LINES AND COLD LINES SEPARATELY (IN THIS CASE DO NOT CONNECT HOT TO COLD AT WATER HEATER). CONNECT TEST GAUGE AND THEN CONNECT SOURCE OF PRESSURE (AIR OR WATER MAY BE USED) TO PIPING SUPPLY SYSTEM. PRESSURIZE SYSTEM TO 100 PSI NO 1LES AND 5SMIN TES.HEIF ISOLATE SHOWSDISCONNECT DROP NSOURCE PRESSUURE THEREEIS A OLEAKPSI INMUST THEBSYSTEM THAT MAINTAINED LEAST HAT REQUIRES REPAIR. AFTER REPAIR IS MADE RETEST THE SYSTEM, 100 PSI MUST BE MAINTAINED FOR AT LEAST 15 MINUTES. DISCONNECT HOT FROM COLD SUPPLY LINE AT WATER HEATER, AND CONNECT TO WATER HEATER. DRAINAGE SYSTEM TEST CONNECT ALL DRAIN DROP OUTS TO COMPLETE ALL FIXTURE DRAINS AND MAIN DRAIN. BE SURE ALL CONNECTIONS ARE MADE PER ENCLOSED DRAIN LAYOUT OR TO COMPLY WITH LOCAL PLUMBING CODES. CAP OR PLUG THE MAIN DRAIN OUTLET. LOCATE THE LOWEST FIXTURE (USUALLY THE SHOWER), THIS WILL BE WHERE YOU NEED TO OBSERVE THE WATER LEVEL. INTRODUCE WATER INTO THE SYSTEM (SEE NOTE #2) UNTIL THAf3 WATERHES DEPTH OF 2" EVIDENCE OIF LEAKS..WEST VISUALLYRE. CHECKEALL CONNECTIONSST SHALL BE MADENED FOR NO ON —SITE FOR LEAKS (FACTORY CONNECTIONS HAVE ALREADY BEEN TESTED). IF WATER LEVEL IN LOWEST FIXTURE HAS NOT CHANGED WITHIN THE MINIMUM 15 MINUTES, AND THERE WAS NO EVIDENCE OF LEAKS AT FITTINGS, THEN THE DRAINAGE SYSTEM TEST IS COMPLETE. FAILURE TO MAINTAIN WATER LEVEL INDICATES A LEAK IN THE SYSTEM AND REQUIRES REPAIR AND RETESTING. NOTES: 1. HOME SHALL BE IN A LEVEL POSITION. 2 SHOWERINTRODUCE WATER TO SYSTEM AT SINK, OR TUB. DO INTRODUCE WATER TO SYSTEM AT TOILET BOWLFOR THISMAAY NOT TRAP AIR WITHIN THE SYSTEM. ❑❑❑❑JACOBSEN HOMES P.O. BO% 368 ❑„ SAFETY HARBOR, FLORIDA 34695 ❑❑ PHONE (727) 726-1138 NOTICE: THESE SPECIFICATIONS AND DRAVANGS ARE OPogNAI. PROPRIETARY, AND CONFIDENT& MATERIALS OF JACOBSEN MANUFACTURING INC. SUCH MATFRM&S An PRONDED TO THE RECIPIENT FER SPECIFIC PIIIPOSES AND MUST BE KEPT CONFIDENT& AND SEW FROM OTIM 44 SU-11-0002 MOBILE HOME SET-UP SET-UP KIT PLUMBING FITTINGS F�id p fl— DIRECTION OF FLOW FITTING NAME: COUPLER SYMBOL ORIENTATION / USE COUPLING PIPE SPLICING DIRECTION OF FLOW FITTING NAME: SANITARY TEE SYMBOL I ORIENTATION / USE SAN. TEE I HORIZONTAL TO VERTICAL ONLY FITTING NAME: LONG TURN 90° ELL SYMBOL ORIENTATION / USE 90' ELL MAY BE USED IN ANY ORIENTATION CHECK THE INSTALLATION INSTRUCTIONS FOR MATERIALS REQUIRED AND PLACEMENT OF FITTINGS, NOTE AS SHOWN IN THE DETAILS THE DIRECTION OF FLOW FOR FITTINGS. ALL PIPING REQUIRED TO FIT BETWEEN FITTINGS IS INCLUDED IN THE SET-UP MATERIALS. THE LENGTHS OF PIPE SHOULD BE CHECKED BEFORE CUTTING TO ENSURE THAT PROPER DROP-OFF IS REMAINING FOR COMPLETION OF PIPE RUNS. FITTING NAME: REDUCER BUSHING SYMBOL ORIENTATION / USE BUSHING REDUCE FITTING PIPE SIZE DIRECTION OF FLOW FITTING NAME: LONG TURN TEE WYE SYMBOL ORIENTATION / USE LTTY I MAY BE USED IN ANY ORIENTATION SET-UP INSTRUCTION SYMBOLS O = 1 1/2" DROP Oi = 1 1/2" DRY VENT O' = 2" DROP O = 2" WET VENT O' = 3" DROP O = 3" MAIN DRAIN — — — — — = 1 1/2" DRAIN LINE = 2" DRAIN LINE = 3" DRAIN.LINE NOTE: USE A GOOD QUALITY CLEANER AND CEMENT LISTED FOR USE WITH PVC PIPING CONNECTIONS. BE SURE TO FOLLOW THE MANUFACTURERS INSRUCTIONS ON THE CONTAINERS. DRY FITTING ALL PARTS TOGETHER IS RECOMENDED BEFORE ANY FITTING AND PIPE JOINT IS GLUED. ❑❑❑❑ JACOBSEN HOMES NOTICE: DRAWN BY: DATE: REV LETTER ❑❑■❑ THESE BPEancnnDNs AND oaAWNGs ARE S.A. 6-6-94 OATERI L PROPRIETARY, AND NUNRDENIING DRAWNG TITLE: ❑„❑ P.O. BOX FLORIDAMATERIALS OF MATERIALS ARE MANUFACTURING _. SAFETY HARBOR, ORI34695 INC. SUCH MATERIALSAREOSESANO MUST BE SET -OP KIT, PL. FITTINGS ❑❑❑❑ PHONE (727) 726-1138 KEPTRECIPIENT FOR CONFIDENTL ANDPSECREiSFAOM OWERS DRANINC NUMBER: SU-11-0010 45 MOBILE HOME SET-UP 2" WET VENT WITH NOT MORE THAN UNVENTED / / (1) FIXTURE DRAIN W.C. DROP / i 2" 3 / / D D i 2" O AI T. VENTED W.C. 3" L DROP / TYPICAL Op / 2" DROP 3 / / / INDICATES BOTTOM / / 31, OF HOME / �1 1/2" VENT - 2" (SEE ALT. FOR UNVENTED OPT. WET VENT W.C. DROP // CONNECTION) O f INSTALL FULL SIZE 1 1/2" 2' CLEAN -OUT IF SLOPE / 3" 2. O IS BETWEEN 1/8" h �" O 1/4" PER FOOT USE OD IF CLEAN- O} 3" TYPICAL OUT IS NOT NEEDED 3" OB 1 1/2" DROP O O / 3„ 1 1 /2" 1 1/2" � O MINIMUM SLOPE y' /j 1/8" PER FT. FITTING SCHEDULE WITH CLEAN -OUT 1/WI PER FT. O VERT. TO HORIZ. (LONG TURN TY OR COMB. Y k 1/8 BEND) WITHOUT CLEAN -OUT O HORIZ. TO HORIZ. (LONG TURN TY OR COMB. Y k 1/8 BEND) © © HORIZ. TO VERT. (1/4 BENO-LONG ELL) OD VERT, TO HORIZ. (LONG SWEEP 1/4 BEND) 3" OE HORIZ. TO VERT. (SHORT TURN TY - SAN. TEE) TO ON SITE DRAIN CONNECTION TYPICAL ON SITE DRAIN CONNECTIONS 3/4" DROP FROM WATER HEATER SECTION / / ' 3/4" DROP 3/4" ELL / �3/4" THREADED INLET / 3/4" TEE AND FRESH WATER INLET FOR NOTE. 3/4" THREADED 3/4" ELL SN NOE S D AND M TI- INLET - FIELD THE TWO EXAMPLES SHOWN ARE WDE5 WITH PLUMBING IN INSTALLED TYPICAL FOR MOST MODELS. ONE SECTION ONLY SOME MODELS DEPENDING 3/4" CROSS -DYERS MAY HAVE A COMBINATION ON THE PLUMBINGCOMBINATION LAY -OUT FRESH WATER INLET FOR (FIELD INSTALLED) OF BOTH OF THE EXAMPLES MULTI-WIDES WITHp PLUMBING SRO IN MORE THAN ONE SECTION TYPICAL FRESH WATER ENTRANCES HOMES �+ NOTICE: DRAWN BY, DATE: REV. LETIE ❑❑❑❑ JACOBSEN HOMES THESE SPECIFICATONSAND DRAWNGSARE S.A. 6-6-94 ❑❑■❑ ORIGINAL, PROPRIETARY, AND GOB IDENIIAL DRAWING TITLE: ❑„❑ P.O. BOX MATERIALS OF JACOBSEN MANUFACTURING DRAIN SET-UP FLORIDA 34695 INC. SUCH MATERIALS ARE PROVOED TD THE SAFETY HARBOR, 726-11 REOPIENT FOR SPEOBC PURPOSES AND MUST BE DRAWING NUMBER: ❑❑❑❑ PHONE (727) 26-1138 KEPT CONFIDENTIAL AND SECRET ROM OTHERS. SU-11-0005 46 WATER LINE CROSS -OVER (SEE DETAIL BELOW) TYPICAL MARRIAGE LINE OF MULTIPLE WIDE HOMES TYPICAL FLOOR ASSEMBLY FLOOR JOIST MAY BE NOTCHED AT PLUMBING CROSS -OVER WATER CROSS -OVER (SEE ELECTRICAL SET-UP FOR SPECIFICATIONS). R-7 INSULATION MINIMUM AND BOTTOM BOARD OVER WATER CROSS -OVER LINES NOTE: NO HEAT TAPE RECEPT. REQUIRED AT INSULATED WATER CROSS -OVER. NOTES: 1, CONNECT WATER LINES TOGETHER AT ALL CROSSOVER LOCATIONS. 2. INSTALL R-7 MINIMUM INSULATION BLANKET OVER THE WATER CROSS -OVER LINES AND SECURE INTO PLACE WITH DUCT TAPE. 3. PLACE A PIECE OF BOTTOM BOARD MATERIAL LARGE ENOUGH TO COVER WATER CROSS -OVER LINES AND INSULATION AND SECURE TO FLOOR FRAMING MEMBERS WITH 1" % 1' % 16 GA. STAPLES MINIMUM AT EACH FRAMING MEMBER, AND TAPE OVER SEAMS WITH CLOTH DUCT TAPE OR EQUAL. ,E p HOMES ❑❑❑❑ JACOBSEN HOMES NOTICE: THESE SPECIFICABONSAND ORAWNGSME OIION&, PROPRIETARY, AND COINCIDENTAL DRAWN BV: C.L.Y. DATE: Oi 10-23-95 REV. LETTER: / \ DRAWING TITLE: ❑❑■❑ MATERIALS OF JACOBSEN MANUFACTURING WATER CROSS -OVER ❑„❑ P.O. BOX 358 INC. SUCH MATERI0.S ARE PROVED) TO THE 'H\ ❑❑❑❑ SAFETY HARBOR, FLORIDA 34695 PHONE (813) 726-1138 REORIENT FOR SPECIRC PuR OSES AND MUST BE KEPT CORROFNDAI ANO SECRET FRdI OHERS. DRAWING NUMBER'. SU-11-0020 MOBILE HOME SET-UP .ML JACOBSEN MOBILE HOMES ARE MADE AIR CONDITIONER READY, WHICH MEANS THE REGISTERS, SUPPLY DUCTS, AND RETURN AIR FACILITIES ARE ALREADY INSTALLED IN YOUR HOME. IN A MULTI — SECTION HOME THERE IS ONE SUPPLY DROP PER SECTION, AND ONE RETURN AIR DROP FOR THE ENTIRE HOME. CONNECT THE RETURN AIR DROP TO THE INTAKE SIDE OF THE AIR CONDITIONING UNIT, AND CONNECT THE SUPPLY DROPS REDUCER "Y" FITTING(S) (i.e., (1) 12" TO (2) 10°) TO THE BLOWER SIDE. FOR SINGLE UNIT HOMES, THERE IS ONE SUPPLY DROP, CONNECT THAT ONE DROP DIRECTLY TO THE BLOWER SIDE OF THE AIR CONDITIONING UNIT. ALL CONNECTIONS BETWEEN THE AIR CONDITIONER AND DROPS CAN BE MADE WITH INSULATED FLEXIBLE DUCT. CHECK THESE ITEMS AFTER THE AIR CONDITIONER IS INSTALLED. 1. ALL DUCT WORK BELOW THE HOME IS INSULATED. 2. ALL SEAMS ARE SEALED. 3. ALL CONNECTIONS ARE INSULATED AND TIGHT FITTING. 4. CROSS —OVER DUCT MUST BE SUPPORTED EVERY 4'-0" O.C. TYPICAL RETURN AIR DROP TYPICAL - SUPPLY DROP TYPICAL SUPPLY DROP REDUCER "Y' -� FITTING I j\\ AIR FLOW UNIT IS SHOWN WITH TWO SUPPLY AND ONE RETURN DUCT(S). THIS WILL VARY BY MODEL, MODELS MAY HAVE MORE OR FEWER SUPPLY OR ALL IN ONE AIR CONOInONER UNIT RETURN DUCTS. (AIR HANDLER, CONDENSER, AND COMPRESSOR) TYPICAL MULTIPLE SECTION A.C. CONNECTIONS NOTE: ON SOME MODELS THE SUPPLY AND/OR RETURN AIR DROPS PROVIDED ON THE HOME MAY BE LOCATED DIRECTLY OVER THE RUNNING GEAR (TIRE AND/OR AXLE). ON HOMES WITH THE DROP LOCATIONS LOCATED ABOVE THE RUNNING GEAR IT IS NECESSARY TO REMOVE THE RUNNING GEAR BEFORE HOOKING UP THE SUPPLY AND/OR RETURN AIR DUCT FROM THE AIR CONDITIONER UNIT TO THE HOME. ❑❑❑❑ JACOBSEN HOMES NOTTOE: THESE SPEgFlCAPONS AND ONAWNGS ARE UtlflMOI: O.A. UflIG 06-06-94 HLY. LIICR: III ---III ❑❑;;I�- P.O. BOX 368 ORIGINAL PROPRIETARY. AND CONFIDENTIAL MATERIALS OF JACOBSON MANUFACTURING DRAWING TITLE: DOUBLE WIDE A.C. CONNECTIONS / \ u ❑❑❑❑ SAFETY HARBOR, FLORIDA 34695 PHONE (727) 726-1138 INC. SUCH MATERIALS ARE PRONDED TO THE RECIPIENT FOR SPECK PURPOSES Ala MUST BE IVT CONRDFNIIAL AND SECRET FROM OT1M DRAWING NUMBER: SU-13-0001 /H\ 09-30-09 ( J MOBILE HOME SET-UP USE THE FOLLOWING INSTRUCTIONS WHERE APPLIED TO DUCTWORK PROVIDED BY JACOBSEN HOMES FOR AIR CONDITIONER INSTALLATION. CHECK THE MANUFACTURERS INSTALLATION INSTRUCTIONS FOR ALL ADDITIONAL DUCTS USED DURING AIR CONDITIONER HOOK-UP FOR RECOMMENDED INSTALLATION PROCEDURES FOR THE TYPE DUCT BEING USED. METHOD PRESSURE DETAILS CONNECTIONS SPLICES LIMITATIONS TAPE ONLY A) FOLD BACK JACKET AND INSULATION A) FOLD BACK JACKET AND INSULATION FROM END OF DUCT EXPOSING CORE. FROM END OF DUCTS EXPOSING CORE. (FOR LOW B) SLIP CDRE OVER FITTING AT LEAST B) INSERT ONE CORE INTO THE OTHER PRESSURE NOT TO EXCEED C) 1 1/2 INCHES. APPLY DUCT TAPE* AROUND CORE AND C) ABOUT THREE INCHES. APPLY DUCT TAPE- AROUND OUTSIDE CONNECTING 2 IN. W.G.) FITTING WITH AN EQUAL TAPE WIDTH ON OF CORE EDGE WITH EQUAL WIDTH ON EACH. EACH CORE. D) PULL BACK INSULATION AND JACKET D) BUTT INSULATION AND PULL JACKET OVER FITTING. FROM ONE DUCT OVER OTHER DUCT. E) APPLY DUCT TAPE- AROUND JACKET E) APPLY DUCT TAPE- AROUND OUTSIDE AND FITTING WITH AN EQUAL TAPE OF JACKET EDGE WITH EQUAL TAPE WIDTH ON EACH. WIDTH ON EACH JACKET. SPLICING CLAMP ONLY METAL CLAMP (FOR LOW TO Fitting or Coupling Bond Clamp A) B) SLIP DUCT OVER FITTING AT LEAST THREE INCHES. PLACE CLAMP.* AROUND DUCT AT FITTING AND TIGHTEN WITH APPROPRIATE A) FOLLOW AS DIRECTED UNDER 'CONNECTIONS' BUTTING TWO DUCTS TOGETHER ON A STANDARD SHEET METAL COUPLING AT LEAST SIX INCHES MEDIUM PRESSURE TOOL UNTIL ALL MATERIAL UNDER CLAMP IN LENGTH. NOT TO EXCEED 4 IN. W.G.) L HAS BEEN COMPRESSED AND CLAMPING PRESSURE IS ASSURED. SEE PRESURE LIMITATIONS FOR PLASTIC CLAMPS-- 3 Duct MIN. C) CHECK CONNECTION BY PULLING ON DUCT WITH A FORCE OF AT LEAST 25 LES. TO INSURE DUCT HAS BEEN ADEQUATELY CLAMPED. CONNECTING OR SPLICING TAPE & CLAMP A) PULL BACK JACKET AND INSULATION A) BUTT TWO CORES TOGETHER ON A SIX FROM END OF DUCT EXPOSING CORE. INCH METAL COUPLING AND FOLLOW (FOR LOW, MEDIUM B) SLIP CORE OVER FITTING AT LEAST DIRECTIONS UNDER 'CONNECTIONS'. OR HIGH PRESSURE 1 1/2 INCHES. NOT TO EXCEED C) APPLY DUCT TAPE. AROUND CORE AND 10 IN. W.G.) FITTING WITH EQUAL TAPE WIDTH ON SEE PRESURE LIMITATIONS FOR CONNECTING 0) EACH. PLACE CLAMP.* AROUND TAPE AND PLASTIC CLAMPS** CORE AND TIGHTEN WITH APPROPRIATE TOOL. E) PULL BACK INSULATION AND JACKET AND APPLY DUCT TAPE* AROUND JACKET AND FITTING. WITH TABBED DUCTBOARD FITTINGS, OUTER JACKET MAY BE 'DIAPERED' INSTEAD OF TAPED (SEE STEP F). SPLICING F) PULL JACKET OVER RING, THROUGH HOLE, AND FOLD UP WITH TABS. • DUCT TAPE: USE A MINIMUM OF ONE WRAP OF 2 INCH OR TWO WRAPS OF 1 1/2 INCH WIDTH OF TYPE SHUFORD #PC622, TUCK #92T, ARNO #C520, POLYKEN #222, OR NASHUA #357, ++ PLASTIC CLAMPS: PLASTIC CLAMPS ARE NOT RECOMMENDED FOR PRESSURES EXCEEDING 4 IN. W.G. (DIAMETERS 3" - 10') AND 2 IN. W.G. (DIAMETERS 12" AND OVER) TO ACHIEVE PROPER TENSIONING OF PLASTIC CLAMP, SET CORRESPONDING TOOL AT MAXIMUM TENSION SETTING. APPROVED TYPES: PANDUIT TYPE PLT-H (TOOL G); CATAMOUNT L-175 (TOOL L-300); OR TYTON T-150 (TOOL T-150). ❑❑❑❑ JACOBSEN HOMES NOTICE: THESE DRAWINGS ARE DRAWN BY: S.A. DATE 6-6-94 REV. LETTER: ORAWNG PRE: MOBILE HOME SET-UP DUCTWORK ❑❑.❑ ❑„❑ ❑❑❑❑ P.O. BOX 368 SAFETY HARBOR, FLORIDA 34695 PHONE (727) 726-1138 L PROPRIETARY, AN ORIGINAL, PROPRIETARY, ANO SENAREMANUFACTURINGROOTWE MATERIALS OF JACOMATERIALS INC. SUCH MATERIALS ARE PRONDEO TO THE REOPIENT FOR SPEORC PURPOSES AND MUST BE KEPT CONROENIIAL NO SECRET FROM OTHERS. DRAWNG NUMBER: 91-13-0010 49 ELECTRIC CLOTHES DRYER VENTING IMPORTANT - BEFORE DRYER IS USED IT MUST BE VENTED TO THE OUTSIDE OF THE HOME. THE VENT MUST NOT TERMINATE INSIDE THE SKIRTED AREA UNDER THE HOME, THIS WOULD RESULT IN EXCESSIVE HUMIDITY IN THE HOME, HOMES SET UP TO RECEIVE A DRYER ARE EQUIPPED WITH A VENT HOLE PRE -DRILLED THROUGH THE FLOOR AT THE DRYER LOCATION. TO COMPLETE THE DRYER EXHAUST SYSTEM, FOLLOW THESE PROCEDURES: 1. REMOVE THE DRYER VENT ACCESS HOLE COVER. 2. CUT DRYER VENT DUCT TO THE PROPER LENGTH, AND CHECK FOR OBSTRUCTIONS. THEN CONNECT TO DRYER IN ACCORDANCE WITH THE MANUFACTURERS INSTRUCTIONS. 3. SECURE THE VENT CAP TO THE OUTSIDE OF THE SKIRTING AT THE APPROPRIATE LOCATION. 4. SECURE THE END OF THE FLEXIBLE DRYER DUCT TO THE VENT CAP AT THE EXTERIOR OF THE HOME WITH CLAMPS. NOTE: DO NOT USE ANY SCREWS OR OTHER DEVICES THAT EXTEND INTO THE DUCT. 5. STRAP THE DRYER DUCT TO THE UNDERSIDE OF THE HOME TO PREVENT THE DUCT FROM COMING IN CONTACT WITH THE GROUND. 6. SEAL THE OPENINGS AROUND THE DUCT WHERE IT PASSES THROUGH THE FLOOR WITH CAULK OR DUCT TAPE, AND THE BOTTOM BOARD WITH DUCT TAPE. JACOBSEN HOMES WILL NOT BE RESPONSIBLE FOR DAMAGE TO THE HOME RESULTING FROM FAILURE TO INSTALL THE DRYER EXHAUST SYSTEM IN ACCORDANCE WITH THE MANUFACTURERS INSTRUCTIONS AND THE INSTRUCTIONS LISTED ABOVE. NOTE: GAS DRYER INSTALLATION MUST BE DONE BY QUALIFIED PERSONNEL. THE CUTTING OF STRUCTURAL ELEMENTS OF THE HOME, SUCH AS RAFTERS OR FLOOR JOISTS TO EXPEDITE INSTALLATION IS PROHIBITED. ANY WEAKENING OF THE STRUCTURE RESULTING FROM SUCH CUTTING IS NOT TH-. RESPONSIBILITY OF JACOBSEN HOMES, AND MAY RESULT IN NEGATING YOUR WARRANTY. NOTES: O❑❑�❑❑JACOBSEN HOMES ❑,.� P.O. BOX 368 ❑❑❑❑ SAFEPHONER(2 )F726-113IDA B4695 NOTICE: unnrvn or R.R. THESE SPECIICATIONS AND DRAWINGS ARE ORIGINAL, PROPRIETARY, AND CONFIDENTIAL DRAWING TITLE: MATERIALS OF JACOBSEN MANUFACTURING ELEGT GLQTN INC. %CH MATERIALS ARE PROMDED TO THE RECIPIENT FOR SELIJ"U PURPOSES AND WSI N DRAWING NUMBER: KEPT CONFIDENPAL AND SECRET FROM OTHERS. 50 INSTALLED DUCT ;T BE METAL X OR RIGID CAP CAP 01-21-00 VER VENTING A SU-15-0001 SITE INSTALLED WATER HEATER PAN DRAIN IMPORTANT - SET-UP OF THIS HOME REQUIRES THAT AN ON -SITE DRAIN BE INSTALLED FROM THE WATER HEATER PAN TO THE EXTERIOR OF THE HOME BEFORE THE WATER HEATER MAY BE USED. WATER HEATER PAN FACTORY INSTALLED DRAIN THROUGH FLOOR AND BOTTOM BOARD SITE INSTALLED DRAIN PIPE AND ELBOW (1/4" PER FOOT MIN. SLOPE) TYP. WATER HEATER II PRESSURE AND TEMPERATURE I � RELIEF LINE I I II II II II II TYP FLOOR SYSTEM In I I I I I I I I PIPE TO BE SUPPORTED 4'-0" O.C. MAX. TYP. I -BEAM DRAIN TO EXTEND PAST THE EXTERIOR WALL LINE AND BE LEFT EXPOSED AND VISIBLE FOR INSPECTION. n (SEE DETAIL 'A') SCREEN FACTORY INSTALLED BETWEEN PIPE AND ELBOW. THIS ASSEMBLY TO BE USED AS OVERFLOW PIPE TERMINATION. DETAIL 'A' (DEALER IS RESPONSIBLE FOR THE SHIP LOOSE W/H PAN PIPE ON SITE INSTALLATION) NOTES: 1.) SITE INSTALLED STRAPPING USED TO MAINTAIN THE REQUIRED SLOPE MAY BE SECURED TO FLOOR FRAMING AND/OR CHASSIS MEMBERS. 2.) SHIP LOOSE DRAIN LINE TO BE THE SAME MATERIALS AS THE FACTORY INSTALLED W/H PAN PIPE. ALL MATERIALS FOR THE COMPLETION OF THE ON SITE DRAIN WILL BE SHIPPED LOOSE. 3.) THE WATER HEATER PRESSURE AND TEMPERATURE RELIEF LINE MAY TERMINATE UNDER THE HOME. WHE-10H JACOBSEN HOMES P.O. BOX 368 SAFETY HARBOR, FLORIDA 34695 PHONE (727) 726-1138 NOTICE: THESE SPECIRCARONS AND DRAWINGS ARE ORIGINAL PROPRIETARY, AM CONFIDENTIAL MATERIALS OF JACOBSEN MANUFACTUPoNG INC. SUCH MATERIALS ARE PRNDED TO THE IEMENT FOR SPECIBC RVOSES AND WST BE IEPT CMDDIBAL RD SECRET FROM OHM UNAM m: M.T. Mnir. 03-08-07 c.. c H D IL Jl DRAWING BTIE: W/H PAN DRAIN DRAWING NUMBER: SU-15-0003 51 DOWN DRAFT RANGE VENTING IMPORTANT - BEFORE RANGE IS USED IT MUST BE VENTED TO THE OUTSIDE OF THE HOME. THE VENT MUST NOT TERMINATE INSIDE THE SKIRTED AREA UNDER THE HOME, THIS WOULD RESULT IN EXCESSIVE HUMIDITY IN THE HOME. HOMES WITH A DOWN DRAFT RANGE ARE EQUIPED WITH EXHAUST DUCT INSTALLED FROM THE RANGE THROUGH THE FLOOR, THE REMAINING DUCT IS SENT WITH THE HOME AND MUSTG.,BE INSTALLED ON SITE. 1. LOCATE DUCT DROP FROM RANGE. (MAY BE EXTENDING THROUGH BOTTOM BOARD, OR SEALED INSIDE) 2. CHECK DUCT PROVIDED FOR PROPER LENGTH, AND OBSTRUCTIONS, THEN CONNECT TO DUCT DROP FROM RANGE IN ACCORDANCE WITH THE MANUFACTURERS INSTRUCTIONS. 3. SECURE THE VENT CAP TO THE OUTSIDE OF THE SKIRTING AT THE APPROPRIATE LOCATION. 4. SECURE THE END OF THE DOWN DRAFT RANGE DUCT TO THE VENT CAP AT THE EXTERIOR OF THE HOME WITH CLAMPS OR SCREWS. NOTE: DO NOT USE ANY FASTENERS THAT CRUSH OR BLOCK THE DUCT. 5. STRAP THE DUCT TO THE UNDERSIDE OF THE HOME TO PREVENT THE DUCT FROM BENDING OR COMING IN CONTACT WITH THE GROUND. 6. SEAL THE OPENINGS AROUND THE DUCT WHERE IT PASSES THROUGH THE FLOOR WITH CAULK OR DUCT TAPE, AND THE BOTTOM BOARD WITH DUCT TAPE. JACOBSEN HOMES WILL NOT BE RESPONSIBLE FOR DAMAGE TO THE HOME RESULTING FROM FAILURE TO INSTALL THE RANGE EXHAUST SYSTEM IN ACCORDANCE WITH THE MANUFACTURERS INSTRUCTIONS, AND THE INSTRUCTIONS LISTED ABOVE. RANCE NOTE: DROP LOCATED DIRECTLY BELOW RANGE BLOWER MOTOR SITE INSTALLED DUCT i VENT CAP ❑❑❑❑ ❑❑■❑ ❑„❑ ❑❑❑❑ JACOBSEN HOMES P.O. BOX 36B SAFETY HARBOR, FLORIDA 34695 PHONE (727) 726-1138 NOTICE: THESE SPECIBCATDNSAND ORAWNGSARE ORIGINAL, PROPRIETARY, AND CONFTOENRAL MATERIALS OF JACOBSEN MANUFACTURING INC. SUCH MATERIALS ARE PROVDED TO THE RROPIENT FOR SPECOC PURPOSES AND MUST BE KEPT CONADENTAL AND SECRET MOM OTHERS urcATm m: UAIL S.A. 6-6-94 DRAFT RANGE VENTING SU-I5-0002 REV. LETTER: — ORAWNG TITLE: DOWN DRAPANG NUMBER: SITE INSTALLED CLOTHES DRYER VENTING DUE TO THE POSSIBILY OF DAMAGE THAT MAY OCCUR DURING TRANSIT, WHICH WILL CREATE A SAFETY HAZARD, VENT PIPING IS TO BE INSTALLED ON SITE, NOTES: THIS INCLUDES INSTALLED DRYERS. (DEALER IS RESPONSIBLE FOR THE SHIP LOOSE DRYER VENT PIPE ON SITE INSTALLATION) NOTICE JACOBSEN HOMES mm LYECfi0ATm AJm ORXDUJ�PROPRIETARY. AR P.O. BOX 368 MAIMALS OF JAM INC.. SUCH YATFRIAIS ARE P SAFETY HARBOR, FLORIDA34695 EVFOR P PHONE (727) 726-1138 VRi COdmBIM AllD SEM 53 M.T. DRYER VENTING I - SU-15-0004 52 BOTTOM BOARD P-TRAP ACCESS PANELS - TAPE APPLIED OVER ALL SEAMS AT PATCH APPROX. 1" - PATCH TO BE SAME MATERIAL AS BOTTOM BOARD BEING REPAIRED. HOLE MAY BE (3) SIDED CUT IN BOTTOM BOARD AND TAPE USED TO SEAL EXISTING MATERIAL BACK OVER OPENING VISUALY INSPECT BOTTOM BOARD OF THE ENTIRE HOUSE TO ASSURE THAT THERE IS NO DAMAGE (RIPS OR TEARS ) AND THE AREA AROUND PROTRUSIONS ARE REPAIRED. P-TRAPS MUST BE CHECKED TO BE SURE THEY ARE WELL INSULATED AND COVERED. NOTES: 1, P-TRAP ACCESS PANELS WALL BE BELOW P-TRAP AREA IN FLOOR. 2. P-TRAP ACCESS PANELS MAY BE 3 OR 4 SIDED, AND WILL HAVE 1 OR 2 ROWS OF TAPE AT THE PERIMETER OF THE PANEL. 3. NORMAL BOTTOM BOARD REPAIRS WILL HAVE ONLY TAPE OVER THE CUT OR DAMAGED AREA, 4. MINOR HOLES AROUND PIPES ETC. MAY BE SEALED WITH TAPE 5. THESE ARE SOME ACCEPTABLE TAPES TO USE FOR REPAIR; SHURTAPE PC658, FIRST LINE 620 WEIDEJE] JACOBSEN HOMES P.O. BOX 368 SAFETY HARBOR, FLORIDA 34695 PHONE (727) 726-1138 NOTICE: THESESPECIFlCATDNSMDDRAWINGSAd MGINAE, PROPRIETARY, AND OONFlDFNRAL MATERIALS OF JACOBSEN MANUFACTUNNC INC. SUCH MATERIALS ARE PRONDED TO THE REORIENT FOR SPECFIC PURPWES AND MUST a KEPT CWMIAL AND SECRET FROM OTHERS. DRAWN BY: D.M.T. DATE: 10-31-01 NLY. LURK: D ILJI !(1 O-OS-OS 1 ) DRAWING TITLE: BOTTOM BOARD P-TRAP ACCESS DRAWWNG NUMBER: SU-155-001 O 54 AIR HANDLER CROSS -OVER CONNECTIONS PLENUM (DUCT CONNECTION BETWEEN CROSS -OVER SUPPLY DISTRIBUTION BOX) DUCTS SHALL BE MADE PER OTHER DETAILS. oo o0 I CEILING BOARD — — — PLENUM (DUCT DISTRIBUTION BOX) UNIT MARRIAGE LINE DUCT RISER(S) (SUPPLY DUCTS) AIR HANDLER A/C SYSTEM (AIR HANDLER, ETC...) A SUPPUED BY OTHERS AIR HANDLER CROSS -OVER ELEVATION VIEW JACOBSEN HOMES NOTICE urcnm Mr: DAL: REV LETTER: THESELeanuRoxs AND lmn ARE C.L.Y. 3-21-95 gtlaNAi, PROPPoETMY, AND CCNFlOENIVL DRAWING R P.O. BOX 368 MATERIALS OF JACOBSEN MRNFACTLLRNG R HANDLER CROSS -OVER INC. S W MATERIALS ARE PROWDED to THE SAFETY HARBOR, FLORIDA 34695 KE T FOR SECNC PURR= AJD wsl BE DRAWING NUMBER: f PHONE (813) 726-1138 )VT COFMRAL AIO YCAEI Z Nm' " SU-AC-01 DD 55