Loading...
HomeMy WebLinkAboutAPPROVED BOBO REVISION- ENERGY CALCEnergyGauge® USA 7.0.00 - FlaRes2020 FBC 7th Edition (2020) Compliant Software Page 1 of 73/11/2021 11:06 AM Project Name: Owner: Builder Name: Permit Office: Jurisdiction: ST LUCIE COUNTY ST LUCIE COUNTY PACE 2000, INC. CHRISTOPHER AND DIANE BOBO BOBO RESIDENCE Street: City, State, Zip: FORT PIERCE , FL , 34982 4955 S. INDIAN RIVER DRIVE Permit Number: Design Location: FL, Fort Pierce County: St. Lucie (Florida Climate Zone 2 ) 1. New construction or existing 2. Single family or multiple family 3. Number of units, if multiple family 4. Number of Bedrooms 5. Is this a worst case? 6. Conditioned floor area above grade (ft²) New (From Plans) Detached 1 No 2699 7. Windows a. U-Factor: S H G C : b. U-Factor: S H G C : c. U-Factor: S H G C : Sgl, U=0.56 153.00 ft² SHGC=0.24 Sgl, U=0.57 144.00 ft² SHGC=0.22 Sgl, U=0.69 96.00 ft² SHGC=0.22 9. Floor Types a. Slab-On-Grade Edge Insulation b. N/A c. N/A R=0.0 2699.00 ft² R=f t ² R=f t ² 10. Wall Types a. Concrete Block - Int Insul, Exterior R=4.1 2670.00 ft² b. Frame - Wood, Adjacent R=11.0 300.00 ft² c. N/A R=f t ² 11. Ceiling Types a. Roof Deck (Unvented)R=20.0 2699.00 ft² f t ² R=b. N/A c. N/A R = f t ² 12. Ducts a. Sup: Attic, Ret: Attic, AH: Attic 13. Cooling systems 14. Heating systems 15. Hot water systems a. Electric Cap: 50 gallons b. Conservation features None d. N/A R=f t ² Area Weighted Average Overhang Depth:6.224 ft. Area Weighted Average SHGC:0.236 Description Area Insulation Area Insulation Area Insulation Area 16. Credits None 4 (476.3 sqft.) (2970.0 sqft.) (2699.0 sqft.) (2699.0 sqft.) Conditioned floor area below grade (ft²) 0 a. Central Unit a. Electric Strip Heat k B t u / h r 40.0 SEER:16.00 Efficiency k B t u / h r Efficiency 27.0 COP:1.00 f t ² R 6 175 EF: 0.980 8. Skylights c. U-Factor:(AVG) S H G C ( A V G ) : N/A N/A f t ² Area Glass/Floor Area: 0.176 Total Proposed Modified Loads: Total Baseline Loads: 91.12 91.73 PASS I hereby certify that the plans and specifications covered by this calculation are in compliance with the Florida Energy Code. PREPARED BY: DATE: I hereby certify that this building, as designed, is in compliance with the Florida Energy Code. OWNER/AGENT: DATE: BUILDING OFFICIAL: DATE: Review of the plans and specifications covered by this calculation indicates compliance with the Florida Energy Code. Before construction is completed this building will be inspected for compliance with Section 553.908 Florida Statutes. - Compliance requires certification by the air handler unit manufacturer that the air handler enclosure qualifies as certified factory-sealed in accordance with R403.3.2.1. - Compliance requires an Air Barrier and Insulation Inspection Checklist in accordance with R402.4.1.1 and this project requires an envelope leakage test report with envelope leakage no greater than 5.00 ACH50 (R402.4.1.2). FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION Florida Department of Business and Professional Regulation - Residential Performance Method FORM R405-2020 3-11-2021 PROJECT Title: Owner Name: # of Units: Builder Name: Permit Office: Jurisdiction: ST LUCIE COUNTY ST LUCIE COUNTY PACE 2000, INC. 1 CHRISTOPHER AND DIANE BOBO RESIDENCE Family Type: New/Existing: Bedrooms: Conditioned Area: Total Stories: Worst Case: Rotate Angle:0 No 1 2699 4 New (From Plans) Detached Address Type: Lot # Block/Subdivision: PlatBook: Street: County: City, State, Zip: FL , 34982 FORT PIERCE , St. Lucie 4955 S. INDIAN RIVER Street Address Comment: Building Type: User Cross Ventilation:No Whole House Fan:No TMY Site Design Temp Int Design Temp Heating Design Daily Temp Design Location 2.5 %97.5 %Degree Days Moisture RangeWinter Summer CLIMATE 90 70 7529962 Low39FL_VERO_BEACH_MUNIFL, Fort Pierce______ Number Name Area Volume BLOCKS 1 Entire House 2699 30201 Number NameAreaVolume SPACES Kitchen Occupants Bedrooms Cooled HeatedInfil ID Finished 1 UTILITY 159 1590 No 0 Yes Yes1Yes 2 BEDROOM 4 215 2150 No 01 Yes Yes1Yes 3 HALL 30 300 No 0 Yes Yes1Yes 4 BATH 3 48 480 No 0 Yes Yes1No 5WIC 4 38 380 No 0 Yes Yes1No 6 BEDROOM 3 144 1440 No 01 Yes Yes1Yes 7WIC 3 32 320 No 0 Yes Yes1No 8 HALLWAY72720 No 0 Yes Yes1Yes 9 BATH 2 72 720 No 0 Yes Yes1Yes 10 CLST 2 24 240 No 0 Yes Yes1Yes 11 BEDROOM 2 144 1440 No 01 Yes Yes1Yes 12 DINING RM 195 2535 No 0 Yes Yes1Yes 13 FOYER 63 819 No 0 Yes Yes1Yes 14 STUDY 122 1464 No 0 Yes Yes1Yes 15 LIVING RM4105330 No 0 Yes Yes1Yes 16 KITCHEN1832196 Yes 0 Yes Yes1No 17 NOOK 143 1716 No 0 Yes Yes1Yes 18 M BATH 190 1900 No 0 Yes Yes1Yes 19 M TOILET24240 No 0 Yes Yes1Yes 20 M WIC 64 640 No 0 Yes Yes1Yes 21 MASTER BEDROO 311 3421 No 01 Yes Yes1Yes 22 PANTRY 16 160 No 0 Yes Yes1No 3/11/2021 11:06 AM EnergyGauge® USA 7.0.00 - FlaRes2020 FBC 7th Edition (2020) Compliant Software Page 2 of 7 FORM R405-2020 INPUT SUMMARY CHECKLIST REPORT # Floor Type Area Tile Wood Carpet FLOORS Perimeter R-Value Joist R-ValueSpace Perimeter 1 159 ft² 100______ Slab-On-Grade Edge Insulation - - - -28 ft UTILITY 2 215 ft² 100______ Slab-On-Grade Edge Insulation - - - -18.9 ft BEDROOM 4 3 30 ft² 100______ Slab-On-Grade Edge Insulation - - - -2 ft HALL 4 48 ft² 100______ Slab-On-Grade Edge Insulation - - - -1 ft BATH 3 5 38 ft² 100______ Slab-On-Grade Edge Insulation - - - -1 ft WIC 4 6 144 ft² 100______ Slab-On-Grade Edge Insulation - - - -12 ft BEDROOM 3 7 32 ft² 100______ Slab-On-Grade Edge Insulation - - - -1 ft WIC 3 8 72 ft² 100______ Slab-On-Grade Edge Insulation - - - -4 ft HALLWAY 9 72 ft² 100______ Slab-On-Grade Edge Insulation - - - -6 ft BATH 2 10 24 ft² 100______ Slab-On-Grade Edge Insulation - - - -2 ft CLST 2 11 144 ft² 100______ Slab-On-Grade Edge Insulation - - - -30 ft BEDROOM 2 12 195 ft² 100______ Slab-On-Grade Edge Insulation - - - -13 ft DINING RM 13 63 ft² 100______ Slab-On-Grade Edge Insulation - - - -7 ft FOYER 14 122 ft² 100______ Slab-On-Grade Edge Insulation - - - -10 ft STUDY 15 410 ft² 100______ Slab-On-Grade Edge Insulation - - - -17 ft LIVING RM 16 183 ft² 100______ Slab-On-Grade Edge Insulation - - - -1 ft KITCHEN 17 143 ft² 100______ Slab-On-Grade Edge Insulation - - - -19 ft NOOK 18 190 ft² 100______ Slab-On-Grade Edge Insulation - - - -25 ft M BATH 19 24 ft² 100______ Slab-On-Grade Edge Insulation - - - -3 ft M TOILET 20 64 ft² 100______ Slab-On-Grade Edge Insulation - - - -8 ft M WIC 21 311 ft² 100______ Slab-On-Grade Edge Insulation - - - -41 ft MASTER BEDRO 22 16 ft² 100______ Slab-On-Grade Edge Insulation - - - -1 ft PANTRY #Type Materials Color Absor. Roof Solar Deck Insul. Pitch ROOF Tested Roof Area Gable Area Emitt Tested EmittSA (deg) Rad Barr 1Hip Metal 3018 ft² Light 0.2 20 26.57______No0 ft² 0.9 NoN ATTIC #Type Ventilation Area RBS IRCCVent Ratio (1 in) ______ 1 Full attic Unvented 2699 ft² N N0 3/11/2021 11:06 AM EnergyGauge® USA 7.0.00 - FlaRes2020 FBC 7th Edition (2020) Compliant Software Page 3 of 7 FORM R405-2020 INPUT SUMMARY CHECKLIST REPORT #Ceiling Type R-Value Area Framing Frac Truss Type CEILING Space Ins Type 1 Under Attic (Unvented)0 159 ft² 0.1 Wood______UTILITY Blown 2 Under Attic (Unvented)0 215 ft² 0.1 Wood______BEDROOM 4 Blown 3 Under Attic (Unvented)0 30 ft² 0.1 Wood______HALL Blown 4 Under Attic (Unvented)0 48 ft² 0.1 Wood______BATH 3 Blown 5 Under Attic (Unvented)0 38 ft² 0.1 Wood______WIC 4 Blown 6 Under Attic (Unvented)0 144 ft² 0.1 Wood______BEDROOM 3 Blown 7 Under Attic (Unvented)0 32 ft² 0.1 Wood______WIC 3 Blown 8 Under Attic (Unvented)0 72 ft² 0.1 Wood______HALLWAY Blown 9 Under Attic (Unvented)0 72 ft² 0.1 Wood______BATH 2 Blown 10 Under Attic (Unvented)0 24 ft² 0.1 Wood______CLST 2 Blown 11 Under Attic (Unvented)0 144 ft² 0.1 Wood______BEDROOM 2 Blown 12 Under Attic (Unvented)0 195 ft² 0.1 Wood______DINING RM Blown 13 Under Attic (Unvented)0 63 ft² 0.1 Wood______FOYER Blown 14 Under Attic (Unvented)0 122 ft² 0.1 Wood______STUDY Blown 15 Under Attic (Unvented)0 410 ft² 0.1 Wood______LIVING RM Blown 16 Under Attic (Unvented)0 183 ft² 0.1 Wood______KITCHEN Blown 17 Under Attic (Unvented)0 143 ft² 0.1 Wood______NOOK Blown 18 Under Attic (Unvented)0 190 ft² 0.1 Wood______M BATH Blown 19 Under Attic (Unvented)0 24 ft² 0.1 Wood______M TOILET Blown 20 Under Attic (Unvented)0 64 ft² 0.1 Wood______M WIC Blown 21 Under Attic (Unvented)0 311 ft² 0.1 Wood______MASTER BEDRO Blown 22 Under Attic (Unvented)0 16 ft² 0.1 Wood______PANTRY Blown WALLS #Wall Type R-Value Area Adjacent Framing Solar Ornt Fraction Absor. HeightWidth Ft In Ft InTo Cavity Sheathing R-ValueSpace Grade% Below 1 4.1 0UTILITY000 2 0 1 0NConcrete Block - Int Insul 0.20Exterior200.0 ft² ____ 2 4.1 0UTILITY000 8 1 0WConcrete Block - Int Insul 0.20Exterior80.0 ft² ____ 3 11 0UTILITY000 2 0 1 0S Frame - Wood 0.20.1Garage200.0 ft² ____ 4 4.1 0BEDROOM 4 000 1 9 1 0SConcrete Block - Int Insul 0.20Exterior190.0 ft² ____ 5 11 0BEDROOM 4 000 1 0 1 0W Frame - Wood 0.20.1Garage100.0 ft² ____ 6 4.1 0HALL000 2 1 0NConcrete Block - Int Insul 0.20Exterior20.0 ft² ____ 7 4.1 0BEDROOM 3 000 1 2 1 0SConcrete Block - Int Insul 0.20Exterior120.0 ft² ____ 8 4.1 0HALLWAY000 4 1 0EConcrete Block - Int Insul 0.20Exterior40.0 ft² ____ 9 4.1 0BATH 2 000 6 1 0SConcrete Block - Int Insul 0.20Exterior60.0 ft² ____ 10 4.1 0CLST 2 000 2 1 0SConcrete Block - Int Insul 0.20Exterior20.0 ft² ____ 11 4.1 0BEDROOM 2 000 6 1 0NConcrete Block - Int Insul 0.20Exterior60.0 ft² ____ 12 4.1 0BEDROOM 2 000 1 2 1 0EConcrete Block - Int Insul 0.20Exterior120.0 ft² ____ 13 4.1 0BEDROOM 2 000 1 2 1 0SConcrete Block - Int Insul 0.20Exterior120.0 ft² ____ 14 4.1 0DINING RM 000 1 3 1 3EConcrete Block - Int Insul 0.20Exterior169.0 ft² ____ 15 4.1 0FOYER000 7 1 3EConcrete Block - Int Insul 0.20Exterior91.0 ft² ____ 16 4.1 0STUDY000 1 0 1 2EConcrete Block - Int Insul 0.20Exterior120.0 ft² ____ 17 4.1 0LIVING RM 000 1 7 1 3WConcrete Block - Int Insul 0.20Exterior221.0 ft² ____ 18 4.1 0NOOK000 8 1 2NConcrete Block - Int Insul 0.20Exterior96.0 ft² ____ 3/11/2021 11:06 AM EnergyGauge® USA 7.0.00 - FlaRes2020 FBC 7th Edition (2020) Compliant Software Page 4 of 7 FORM R405-2020 INPUT SUMMARY CHECKLIST REPORT WALLS #Wall Type R-Value Area Adjacent Framing Solar Ornt Fraction Absor. HeightWidth Ft In Ft InTo Cavity Sheathing R-ValueSpace Grade% Below 19 4.1 0NOOK000 1 1 1 2WConcrete Block - Int Insul 0.20Exterior132.0 ft² ____ 20 4.1 0M BATH 000 1 1 1 0NConcrete Block - Int Insul 0.20Exterior110.0 ft² ____ 21 4.1 0M BATH 000 1 4 1 0WConcrete Block - Int Insul 0.20Exterior140.0 ft² ____ 22 4.1 0M TOILET 000 3 1 0NConcrete Block - Int Insul 0.20Exterior30.0 ft² ____ 23 4.1 0M WIC 000 8 1 0NConcrete Block - Int Insul 0.20Exterior80.0 ft² ____ 24 4.1 0MASTER BE 000 1 9 1 1NConcrete Block - Int Insul 0.20Exterior209.0 ft² ____ 25 4.1 0MASTER BE 000 1 5 1 1EConcrete Block - Int Insul 0.20Exterior165.0 ft² ____ 26 4.1 0MASTER BE 000 6 1 1SConcrete Block - Int Insul 0.20Exterior66.0 ft² ____ 27 4.1 0MASTER BE 000 1 1 1WConcrete Block - Int Insul 0.20Exterior11.0 ft² ____ #Door Type U-Value AreaStorms DOORS Ornt Space Width Ft In Ft In Height 1 Insulated .23 21.3 ft² None______N UTILITY 882 2 Insulated .23 21.3 ft² None______S UTILITY 882 # Ornt Panes NFRC U-Factor SHGC Area Depth Separation Int ShadeFrame Screening WINDOWS Overhang Orientation shown is the entered, Proposed orientation. Wall ID Imp 1S Low-E Single 0.56 0.24 30.0 ft² 2 ft 0 in 1 ft 4 in NoneMetal None______Yes4 Y 2S Low-E Single 0.56 0.24 15.0 ft² 2 ft 0 in 1 ft 4 in NoneMetal None______Yes7 Y 3S Low-E Single 0.56 0.24 12.0 ft² 2 ft 0 in 1 ft 4 in NoneMetal None______Yes9 Y 4E Low-E Single 0.57 0.22 36.0 ft² 2 ft 0 in 1 ft 4 in NoneMetal None______Yes12 Y 5E Low-E Single 0.39 0.25 7.0 ft² 8 ft 0 in 1 ft 4 in Drapes/blindsMetal Exterior 5______Yes14 Y 6E Low-E Single 0.57 0.22 36.0 ft² 8 ft 0 in 1 ft 4 in Drapes/blindsMetal Exterior 5______Yes14 Y 7E Low-E Single 0.3 0.28 48.0 ft² 8 ft 0 in 1 ft 4 in Drapes/blindsMetal Exterior 5______Yes15 Y 8E Low-E Single 0.39 0.25 7.0 ft² 8 ft 0 in 1 ft 4 in NoneMetal None______Yes16 Y 9E Low-E Single 0.57 0.22 36.0 ft² 8 ft 0 in 1 ft 4 in NoneMetal None______Yes16 Y 10 W Low-E Single 0.69 0.22 96.0 ft² 12 ft 0 in 1 f t 4 in NoneMetal None______Yes17 Y 11 N Low-E Single 0.3 0.28 21.3 ft² 8 ft 0 in 1 ft 4 in NoneMetal None______Yes18 Y 12 W Low-E Single 0.56 0.24 24.0 ft² 2 ft 0 in 1 ft 4 in NoneMetal None______Yes19 Y 13 N Low-E Single 0.56 0.24 20.0 ft² 2 ft 0 in 1 ft 4 in NoneMetal None______Yes20 Y 14 W Low-E Single 0.56 0.24 12.0 ft² 12 ft 0 in 1 f t 4 in NoneMetal None______Yes21 Y 15 N Low-E Single 0.56 0.24 40.0 ft² 2 ft 0 in 1 ft 4 in NoneMetal None______Yes24 Y 16 E Low-E Single 0.57 0.22 36.0 ft² 2 ft 0 in 1 ft 4 in NoneMetal None______Yes25 Y 3/11/2021 11:06 AM EnergyGauge® USA 7.0.00 - FlaRes2020 FBC 7th Edition (2020) Compliant Software Page 5 of 7 FORM R405-2020 INPUT SUMMARY CHECKLIST REPORT # Floor Area Ceiling Area Exposed Wall Perimeter Avg. Wall Height Exposed Wall Insulation GARAGE 1 640 ft² 640 ft² 30 ft 10 ft 11______ Method CFM 50 ACH 50ELASLAScope INFILTRATION ACHEqLA# 2516.8 5138.08.000355Wholehouse .1032259.22Proposed ACH(50)1 HEATING SYSTEM # System Type Efficiency Capacity DuctsSubtypeBlockSpeed 1 Electric Strip Heat/COP:1 27 kBtu/hr ______sys#1None1 # System Type Efficiency Capacity Air Flow SHR COOLING SYSTEM DuctsSubtypeBlockSubtype 1 Central Unit/SEER: 16 40 kBtu/hr 1200 cfm 0.8______sys#1Split1 Single # System Type EF Cap Use SetPnt Conservation HOT WATER SYSTEM SubType Location 1 Electric 0.98 50 gal 62.3 gal 120 deg None______None Garage FSEC Company Name System Model #Collector Model # Collector SOLAR HOT WATER SYSTEM Storage FEFCert #Area Volume None None f t ² ______ # Location R-Value Area Location Area ---- Supply -------- Return ---- Leakage Type Handler CFM 25Air QN RLF DUCTS Heat Cool HVAC # TOT OUT CFM25 1 Attic 6 175 ft² Attic 18 ft² Default Leakage Attic (Default) c______1 1 (Default) c 3/11/2021 11:06 AM EnergyGauge® USA 7.0.00 - FlaRes2020 FBC 7th Edition (2020) Compliant Software Page 6 of 7 FORM R405-2020 INPUT SUMMARY CHECKLIST REPORT TEMPERATURES Programable Thermostat: N Ceiling Fans: Cooling [ ] Jan [ ] Feb [ ] Mar [ ] Apr [ ] May [X] Jul [X] Aug [X] Sep [ ] Oct [ ] Nov [ ] Dec [ ] Dec [X] Dec[X] Nov [X] Nov [ ] Oct [X] Oct [ ] Sep [ ] Sep [ ] Aug [ ] Aug [ ] Jul [ ] Jul[ ] Jun [ ] Jun [X] Jun [ ] May [ ] May [ ] Apr [X] Apr [X] Mar [X] Mar [X] Feb [ ] Feb [X] Jan [ ] Jan Heating Venting Thermostat Schedule:HERS 2006 Reference Hours Schedule Type 12345678910 11 12 Cooling (WD)AM PM 78 80 78 80 78 80 78 80 78 78 78 78 78 78 78 78 80 78 80 78 80 78 80 78 Cooling (WEH)AM PM 78 80 78 80 78 80 78 80 78 78 78 78 78 78 78 78 80 78 80 78 80 78 80 78 Heating (WD)AM PM 65 68 65 68 65 68 65 68 65 68 65 68 65 68 68 68 68 68 68 68 68 68 68 68 Heating (WEH)AM PM 65 68 65 68 65 68 65 68 65 68 65 68 65 68 68 68 68 68 68 68 68 68 68 68 MASS Mass Type Area T hickness Furniture Fraction Space Default(8 lbs/sq.ft.0 ft² 0 ft 0.3 OFFICE Default(8 lbs/sq.ft.f t ² f t 0.3 MASTER BEDROO Default(8 lbs/sq.ft.f t ² f t 0.3 M WIC 1 Default(8 lbs/sq.ft.f t ² f t 0.3 M TOILET Default(8 lbs/sq.ft.f t ² f t 0.3 M BATH Default(8 lbs/sq.ft.f t ² f t 0.3 M WIC 2 Default(8 lbs/sq.ft.f t ² f t 0.3 M HALL Default(8 lbs/sq.ft.f t ² f t 0.3 LIVING RM Default(8 lbs/sq.ft.f t ² f t 0.3 FOYER/DINING Default(8 lbs/sq.ft.f t ² f t 0.3 KITCHEN Default(8 lbs/sq.ft.f t ² f t 0.3 LAUNDRY Default(8 lbs/sq.ft.f t ² f t 0.3 BEDROOM 3 Default(8 lbs/sq.ft.f t ² f t 0.3 BATH 2 Default(8 lbs/sq.ft.f t ² f t 0.3 BEDROOM 2 Default(8 lbs/sq.ft.f t ² f t 0.3 WIC 2 Default(8 lbs/sq.ft.f t ² f t 0.3 BATH 3 Default(8 lbs/sq.ft.f t ² f t 0.3 HALL Default(8 lbs/sq.ft.f t ² f t 0.3 CLST 3 3/11/2021 11:06 AM EnergyGauge® USA 7.0.00 - FlaRes2020 FBC 7th Edition (2020) Compliant Software Page 7 of 7 FORM R405-2020 INPUT SUMMARY CHECKLIST REPORT ��������������������������������������������������������������������������� ��������������������������������������������������������������������������������� �����������������������������������������������������