HomeMy WebLinkAboutAPPROVED BOBO REVISION- ENERGY CALCEnergyGauge® USA 7.0.00 - FlaRes2020 FBC 7th Edition (2020) Compliant Software Page 1 of 73/11/2021 11:06 AM
Project Name:
Owner:
Builder Name:
Permit Office:
Jurisdiction: ST LUCIE COUNTY
ST LUCIE COUNTY
PACE 2000, INC.
CHRISTOPHER AND DIANE BOBO
BOBO RESIDENCE
Street:
City, State, Zip: FORT PIERCE , FL , 34982
4955 S. INDIAN RIVER DRIVE
Permit Number:
Design Location: FL, Fort Pierce County: St. Lucie (Florida Climate Zone 2 )
1. New construction or existing
2. Single family or multiple family
3. Number of units, if multiple family
4. Number of Bedrooms
5. Is this a worst case?
6. Conditioned floor area above grade (ft²)
New (From Plans)
Detached
1
No
2699
7. Windows
a. U-Factor:
S H G C :
b. U-Factor:
S H G C :
c. U-Factor:
S H G C :
Sgl, U=0.56 153.00 ft²
SHGC=0.24
Sgl, U=0.57 144.00 ft²
SHGC=0.22
Sgl, U=0.69 96.00 ft²
SHGC=0.22
9. Floor Types
a. Slab-On-Grade Edge Insulation
b. N/A
c. N/A
R=0.0 2699.00 ft²
R=f t ²
R=f t ²
10. Wall Types
a. Concrete Block - Int Insul, Exterior R=4.1 2670.00 ft²
b. Frame - Wood, Adjacent R=11.0 300.00 ft²
c. N/A R=f t ²
11. Ceiling Types
a. Roof Deck (Unvented)R=20.0 2699.00 ft²
f t ² R=b. N/A
c. N/A R = f t ²
12. Ducts
a. Sup: Attic, Ret: Attic, AH: Attic
13. Cooling systems
14. Heating systems
15. Hot water systems
a. Electric Cap: 50 gallons
b. Conservation features
None
d. N/A R=f t ²
Area Weighted Average Overhang Depth:6.224 ft.
Area Weighted Average SHGC:0.236
Description Area
Insulation Area
Insulation Area
Insulation Area
16. Credits None
4
(476.3 sqft.)
(2970.0 sqft.)
(2699.0 sqft.)
(2699.0 sqft.)
Conditioned floor area below grade (ft²) 0
a. Central Unit
a. Electric Strip Heat
k B t u / h r
40.0 SEER:16.00
Efficiency
k B t u / h r Efficiency
27.0 COP:1.00
f t ² R
6 175
EF: 0.980
8. Skylights
c. U-Factor:(AVG)
S H G C ( A V G ) :
N/A
N/A
f t ²
Area
Glass/Floor Area: 0.176
Total Proposed Modified Loads:
Total Baseline Loads:
91.12
91.73 PASS
I hereby certify that the plans and specifications covered by
this calculation are in compliance with the Florida Energy
Code.
PREPARED BY:
DATE:
I hereby certify that this building, as designed, is in compliance
with the Florida Energy Code.
OWNER/AGENT:
DATE:
BUILDING OFFICIAL:
DATE:
Review of the plans and
specifications covered by this
calculation indicates compliance
with the Florida Energy Code.
Before construction is completed
this building will be inspected for
compliance with Section 553.908
Florida Statutes.
- Compliance requires certification by the air handler unit manufacturer that the air handler enclosure qualifies as
certified factory-sealed in accordance with R403.3.2.1.
- Compliance requires an Air Barrier and Insulation Inspection Checklist in accordance with R402.4.1.1 and this project requires
an envelope leakage test report with envelope leakage no greater than 5.00 ACH50 (R402.4.1.2).
FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION
Florida Department of Business and Professional Regulation - Residential Performance Method
FORM R405-2020
3-11-2021
PROJECT
Title:
Owner Name:
# of Units:
Builder Name:
Permit Office:
Jurisdiction: ST LUCIE COUNTY
ST LUCIE COUNTY
PACE 2000, INC.
1
CHRISTOPHER AND DIANE
BOBO RESIDENCE
Family Type:
New/Existing:
Bedrooms:
Conditioned Area:
Total Stories:
Worst Case:
Rotate Angle:0
No
1
2699
4
New (From Plans)
Detached
Address Type:
Lot #
Block/Subdivision:
PlatBook:
Street:
County:
City, State, Zip:
FL , 34982
FORT PIERCE ,
St. Lucie
4955 S. INDIAN RIVER
Street Address
Comment:
Building Type: User
Cross Ventilation:No
Whole House Fan:No
TMY Site
Design Temp Int Design Temp Heating Design Daily Temp
Design Location 2.5 %97.5 %Degree Days Moisture RangeWinter Summer
CLIMATE
90 70 7529962 Low39FL_VERO_BEACH_MUNIFL, Fort Pierce______
Number Name Area Volume
BLOCKS
1 Entire House 2699 30201
Number NameAreaVolume
SPACES
Kitchen Occupants Bedrooms Cooled HeatedInfil ID Finished
1 UTILITY 159 1590 No 0 Yes Yes1Yes
2 BEDROOM 4 215 2150 No 01 Yes Yes1Yes
3 HALL 30 300 No 0 Yes Yes1Yes
4 BATH 3 48 480 No 0 Yes Yes1No
5WIC 4 38 380 No 0 Yes Yes1No
6 BEDROOM 3 144 1440 No 01 Yes Yes1Yes
7WIC 3 32 320 No 0 Yes Yes1No
8 HALLWAY72720 No 0 Yes Yes1Yes
9 BATH 2 72 720 No 0 Yes Yes1Yes
10 CLST 2 24 240 No 0 Yes Yes1Yes
11 BEDROOM 2 144 1440 No 01 Yes Yes1Yes
12 DINING RM 195 2535 No 0 Yes Yes1Yes
13 FOYER 63 819 No 0 Yes Yes1Yes
14 STUDY 122 1464 No 0 Yes Yes1Yes
15 LIVING RM4105330 No 0 Yes Yes1Yes
16 KITCHEN1832196 Yes 0 Yes Yes1No
17 NOOK 143 1716 No 0 Yes Yes1Yes
18 M BATH 190 1900 No 0 Yes Yes1Yes
19 M TOILET24240 No 0 Yes Yes1Yes
20 M WIC 64 640 No 0 Yes Yes1Yes
21 MASTER BEDROO 311 3421 No 01 Yes Yes1Yes
22 PANTRY 16 160 No 0 Yes Yes1No
3/11/2021 11:06 AM EnergyGauge® USA 7.0.00 - FlaRes2020 FBC 7th Edition (2020) Compliant Software Page 2 of 7
FORM R405-2020 INPUT SUMMARY CHECKLIST REPORT
# Floor Type Area Tile Wood Carpet
FLOORS
Perimeter R-Value Joist R-ValueSpace Perimeter
1 159 ft² 100______ Slab-On-Grade Edge Insulation - - - -28 ft UTILITY
2 215 ft² 100______ Slab-On-Grade Edge Insulation - - - -18.9 ft BEDROOM 4
3 30 ft² 100______ Slab-On-Grade Edge Insulation - - - -2 ft HALL
4 48 ft² 100______ Slab-On-Grade Edge Insulation - - - -1 ft BATH 3
5 38 ft² 100______ Slab-On-Grade Edge Insulation - - - -1 ft WIC 4
6 144 ft² 100______ Slab-On-Grade Edge Insulation - - - -12 ft BEDROOM 3
7 32 ft² 100______ Slab-On-Grade Edge Insulation - - - -1 ft WIC 3
8 72 ft² 100______ Slab-On-Grade Edge Insulation - - - -4 ft HALLWAY
9 72 ft² 100______ Slab-On-Grade Edge Insulation - - - -6 ft BATH 2
10 24 ft² 100______ Slab-On-Grade Edge Insulation - - - -2 ft CLST 2
11 144 ft² 100______ Slab-On-Grade Edge Insulation - - - -30 ft BEDROOM 2
12 195 ft² 100______ Slab-On-Grade Edge Insulation - - - -13 ft DINING RM
13 63 ft² 100______ Slab-On-Grade Edge Insulation - - - -7 ft FOYER
14 122 ft² 100______ Slab-On-Grade Edge Insulation - - - -10 ft STUDY
15 410 ft² 100______ Slab-On-Grade Edge Insulation - - - -17 ft LIVING RM
16 183 ft² 100______ Slab-On-Grade Edge Insulation - - - -1 ft KITCHEN
17 143 ft² 100______ Slab-On-Grade Edge Insulation - - - -19 ft NOOK
18 190 ft² 100______ Slab-On-Grade Edge Insulation - - - -25 ft M BATH
19 24 ft² 100______ Slab-On-Grade Edge Insulation - - - -3 ft M TOILET
20 64 ft² 100______ Slab-On-Grade Edge Insulation - - - -8 ft M WIC
21 311 ft² 100______ Slab-On-Grade Edge Insulation - - - -41 ft MASTER BEDRO
22 16 ft² 100______ Slab-On-Grade Edge Insulation - - - -1 ft PANTRY
#Type Materials Color Absor.
Roof Solar Deck
Insul.
Pitch
ROOF
Tested
Roof
Area
Gable
Area
Emitt
Tested
EmittSA
(deg)
Rad
Barr
1Hip Metal 3018 ft² Light 0.2 20 26.57______No0 ft² 0.9 NoN
ATTIC
#Type Ventilation Area RBS IRCCVent Ratio (1 in)
______ 1 Full attic Unvented 2699 ft² N N0
3/11/2021 11:06 AM EnergyGauge® USA 7.0.00 - FlaRes2020 FBC 7th Edition (2020) Compliant Software Page 3 of 7
FORM R405-2020 INPUT SUMMARY CHECKLIST REPORT
#Ceiling Type R-Value Area Framing Frac Truss Type
CEILING
Space Ins Type
1 Under Attic (Unvented)0 159 ft² 0.1 Wood______UTILITY Blown
2 Under Attic (Unvented)0 215 ft² 0.1 Wood______BEDROOM 4 Blown
3 Under Attic (Unvented)0 30 ft² 0.1 Wood______HALL Blown
4 Under Attic (Unvented)0 48 ft² 0.1 Wood______BATH 3 Blown
5 Under Attic (Unvented)0 38 ft² 0.1 Wood______WIC 4 Blown
6 Under Attic (Unvented)0 144 ft² 0.1 Wood______BEDROOM 3 Blown
7 Under Attic (Unvented)0 32 ft² 0.1 Wood______WIC 3 Blown
8 Under Attic (Unvented)0 72 ft² 0.1 Wood______HALLWAY Blown
9 Under Attic (Unvented)0 72 ft² 0.1 Wood______BATH 2 Blown
10 Under Attic (Unvented)0 24 ft² 0.1 Wood______CLST 2 Blown
11 Under Attic (Unvented)0 144 ft² 0.1 Wood______BEDROOM 2 Blown
12 Under Attic (Unvented)0 195 ft² 0.1 Wood______DINING RM Blown
13 Under Attic (Unvented)0 63 ft² 0.1 Wood______FOYER Blown
14 Under Attic (Unvented)0 122 ft² 0.1 Wood______STUDY Blown
15 Under Attic (Unvented)0 410 ft² 0.1 Wood______LIVING RM Blown
16 Under Attic (Unvented)0 183 ft² 0.1 Wood______KITCHEN Blown
17 Under Attic (Unvented)0 143 ft² 0.1 Wood______NOOK Blown
18 Under Attic (Unvented)0 190 ft² 0.1 Wood______M BATH Blown
19 Under Attic (Unvented)0 24 ft² 0.1 Wood______M TOILET Blown
20 Under Attic (Unvented)0 64 ft² 0.1 Wood______M WIC Blown
21 Under Attic (Unvented)0 311 ft² 0.1 Wood______MASTER BEDRO Blown
22 Under Attic (Unvented)0 16 ft² 0.1 Wood______PANTRY Blown
WALLS
#Wall Type R-Value Area
Adjacent Framing Solar
Ornt Fraction Absor.
HeightWidth
Ft In Ft InTo
Cavity Sheathing
R-ValueSpace Grade%
Below
1 4.1 0UTILITY000 2 0 1 0NConcrete Block - Int Insul 0.20Exterior200.0 ft² ____
2 4.1 0UTILITY000 8 1 0WConcrete Block - Int Insul 0.20Exterior80.0 ft² ____
3 11 0UTILITY000 2 0 1 0S Frame - Wood 0.20.1Garage200.0 ft² ____
4 4.1 0BEDROOM 4 000 1 9 1 0SConcrete Block - Int Insul 0.20Exterior190.0 ft² ____
5 11 0BEDROOM 4 000 1 0 1 0W Frame - Wood 0.20.1Garage100.0 ft² ____
6 4.1 0HALL000 2 1 0NConcrete Block - Int Insul 0.20Exterior20.0 ft² ____
7 4.1 0BEDROOM 3 000 1 2 1 0SConcrete Block - Int Insul 0.20Exterior120.0 ft² ____
8 4.1 0HALLWAY000 4 1 0EConcrete Block - Int Insul 0.20Exterior40.0 ft² ____
9 4.1 0BATH 2 000 6 1 0SConcrete Block - Int Insul 0.20Exterior60.0 ft² ____
10 4.1 0CLST 2 000 2 1 0SConcrete Block - Int Insul 0.20Exterior20.0 ft² ____
11 4.1 0BEDROOM 2 000 6 1 0NConcrete Block - Int Insul 0.20Exterior60.0 ft² ____
12 4.1 0BEDROOM 2 000 1 2 1 0EConcrete Block - Int Insul 0.20Exterior120.0 ft² ____
13 4.1 0BEDROOM 2 000 1 2 1 0SConcrete Block - Int Insul 0.20Exterior120.0 ft² ____
14 4.1 0DINING RM 000 1 3 1 3EConcrete Block - Int Insul 0.20Exterior169.0 ft² ____
15 4.1 0FOYER000 7 1 3EConcrete Block - Int Insul 0.20Exterior91.0 ft² ____
16 4.1 0STUDY000 1 0 1 2EConcrete Block - Int Insul 0.20Exterior120.0 ft² ____
17 4.1 0LIVING RM 000 1 7 1 3WConcrete Block - Int Insul 0.20Exterior221.0 ft² ____
18 4.1 0NOOK000 8 1 2NConcrete Block - Int Insul 0.20Exterior96.0 ft² ____
3/11/2021 11:06 AM EnergyGauge® USA 7.0.00 - FlaRes2020 FBC 7th Edition (2020) Compliant Software Page 4 of 7
FORM R405-2020 INPUT SUMMARY CHECKLIST REPORT
WALLS
#Wall Type R-Value Area
Adjacent Framing Solar
Ornt Fraction Absor.
HeightWidth
Ft In Ft InTo
Cavity Sheathing
R-ValueSpace Grade%
Below
19 4.1 0NOOK000 1 1 1 2WConcrete Block - Int Insul 0.20Exterior132.0 ft² ____
20 4.1 0M BATH 000 1 1 1 0NConcrete Block - Int Insul 0.20Exterior110.0 ft² ____
21 4.1 0M BATH 000 1 4 1 0WConcrete Block - Int Insul 0.20Exterior140.0 ft² ____
22 4.1 0M TOILET 000 3 1 0NConcrete Block - Int Insul 0.20Exterior30.0 ft² ____
23 4.1 0M WIC 000 8 1 0NConcrete Block - Int Insul 0.20Exterior80.0 ft² ____
24 4.1 0MASTER BE 000 1 9 1 1NConcrete Block - Int Insul 0.20Exterior209.0 ft² ____
25 4.1 0MASTER BE 000 1 5 1 1EConcrete Block - Int Insul 0.20Exterior165.0 ft² ____
26 4.1 0MASTER BE 000 6 1 1SConcrete Block - Int Insul 0.20Exterior66.0 ft² ____
27 4.1 0MASTER BE 000 1 1 1WConcrete Block - Int Insul 0.20Exterior11.0 ft² ____
#Door Type U-Value AreaStorms
DOORS
Ornt Space Width
Ft In Ft In
Height
1 Insulated .23 21.3 ft² None______N UTILITY 882
2 Insulated .23 21.3 ft² None______S UTILITY 882
# Ornt Panes NFRC U-Factor SHGC Area Depth Separation Int ShadeFrame Screening
WINDOWS
Overhang
Orientation shown is the entered, Proposed orientation.
Wall
ID Imp
1S Low-E Single 0.56 0.24 30.0 ft² 2 ft 0 in 1 ft 4 in NoneMetal None______Yes4 Y
2S Low-E Single 0.56 0.24 15.0 ft² 2 ft 0 in 1 ft 4 in NoneMetal None______Yes7 Y
3S Low-E Single 0.56 0.24 12.0 ft² 2 ft 0 in 1 ft 4 in NoneMetal None______Yes9 Y
4E Low-E Single 0.57 0.22 36.0 ft² 2 ft 0 in 1 ft 4 in NoneMetal None______Yes12 Y
5E Low-E Single 0.39 0.25 7.0 ft² 8 ft 0 in 1 ft 4 in Drapes/blindsMetal Exterior 5______Yes14 Y
6E Low-E Single 0.57 0.22 36.0 ft² 8 ft 0 in 1 ft 4 in Drapes/blindsMetal Exterior 5______Yes14 Y
7E Low-E Single 0.3 0.28 48.0 ft² 8 ft 0 in 1 ft 4 in Drapes/blindsMetal Exterior 5______Yes15 Y
8E Low-E Single 0.39 0.25 7.0 ft² 8 ft 0 in 1 ft 4 in NoneMetal None______Yes16 Y
9E Low-E Single 0.57 0.22 36.0 ft² 8 ft 0 in 1 ft 4 in NoneMetal None______Yes16 Y
10 W Low-E Single 0.69 0.22 96.0 ft² 12 ft 0 in 1 f t 4 in NoneMetal None______Yes17 Y
11 N Low-E Single 0.3 0.28 21.3 ft² 8 ft 0 in 1 ft 4 in NoneMetal None______Yes18 Y
12 W Low-E Single 0.56 0.24 24.0 ft² 2 ft 0 in 1 ft 4 in NoneMetal None______Yes19 Y
13 N Low-E Single 0.56 0.24 20.0 ft² 2 ft 0 in 1 ft 4 in NoneMetal None______Yes20 Y
14 W Low-E Single 0.56 0.24 12.0 ft² 12 ft 0 in 1 f t 4 in NoneMetal None______Yes21 Y
15 N Low-E Single 0.56 0.24 40.0 ft² 2 ft 0 in 1 ft 4 in NoneMetal None______Yes24 Y
16 E Low-E Single 0.57 0.22 36.0 ft² 2 ft 0 in 1 ft 4 in NoneMetal None______Yes25 Y
3/11/2021 11:06 AM EnergyGauge® USA 7.0.00 - FlaRes2020 FBC 7th Edition (2020) Compliant Software Page 5 of 7
FORM R405-2020 INPUT SUMMARY CHECKLIST REPORT
# Floor Area Ceiling Area Exposed Wall Perimeter Avg. Wall Height Exposed Wall Insulation
GARAGE
1 640 ft² 640 ft² 30 ft 10 ft 11______
Method CFM 50 ACH 50ELASLAScope
INFILTRATION
ACHEqLA#
2516.8 5138.08.000355Wholehouse .1032259.22Proposed ACH(50)1
HEATING SYSTEM
# System Type Efficiency Capacity DuctsSubtypeBlockSpeed
1 Electric Strip Heat/COP:1 27 kBtu/hr ______sys#1None1
# System Type Efficiency Capacity Air Flow SHR
COOLING SYSTEM
DuctsSubtypeBlockSubtype
1 Central Unit/SEER: 16 40 kBtu/hr 1200 cfm 0.8______sys#1Split1 Single
# System Type EF Cap Use SetPnt Conservation
HOT WATER SYSTEM
SubType Location
1 Electric 0.98 50 gal 62.3 gal 120 deg None______None Garage
FSEC
Company Name System Model #Collector Model #
Collector
SOLAR HOT WATER SYSTEM
Storage
FEFCert #Area Volume
None None f t ² ______
# Location R-Value Area Location Area
---- Supply -------- Return ----
Leakage Type Handler
CFM 25Air
QN RLF
DUCTS
Heat Cool
HVAC #
TOT OUT
CFM25
1 Attic 6 175 ft² Attic 18 ft² Default Leakage Attic (Default) c______1 1 (Default) c
3/11/2021 11:06 AM EnergyGauge® USA 7.0.00 - FlaRes2020 FBC 7th Edition (2020) Compliant Software Page 6 of 7
FORM R405-2020 INPUT SUMMARY CHECKLIST REPORT
TEMPERATURES
Programable Thermostat: N Ceiling Fans:
Cooling [ ] Jan [ ] Feb [ ] Mar [ ] Apr [ ] May [X] Jul [X] Aug [X] Sep [ ] Oct [ ] Nov [ ] Dec
[ ] Dec
[X] Dec[X] Nov
[X] Nov
[ ] Oct
[X] Oct
[ ] Sep
[ ] Sep
[ ] Aug
[ ] Aug
[ ] Jul
[ ] Jul[ ] Jun
[ ] Jun
[X] Jun
[ ] May
[ ] May
[ ] Apr
[X] Apr
[X] Mar
[X] Mar
[X] Feb
[ ] Feb
[X] Jan
[ ] Jan
Heating
Venting
Thermostat Schedule:HERS 2006 Reference Hours
Schedule Type 12345678910 11 12
Cooling (WD)AM
PM
78
80
78
80
78
80
78
80
78
78
78
78
78
78
78
78
80
78
80
78
80
78
80
78
Cooling (WEH)AM
PM
78
80
78
80
78
80
78
80
78
78
78
78
78
78
78
78
80
78
80
78
80
78
80
78
Heating (WD)AM
PM
65
68
65
68
65
68
65
68
65
68
65
68
65
68
68
68
68
68
68
68
68
68
68
68
Heating (WEH)AM
PM
65
68
65
68
65
68
65
68
65
68
65
68
65
68
68
68
68
68
68
68
68
68
68
68
MASS
Mass Type Area T hickness Furniture Fraction Space
Default(8 lbs/sq.ft.0 ft² 0 ft 0.3 OFFICE
Default(8 lbs/sq.ft.f t ² f t 0.3 MASTER BEDROO
Default(8 lbs/sq.ft.f t ² f t 0.3 M WIC 1
Default(8 lbs/sq.ft.f t ² f t 0.3 M TOILET
Default(8 lbs/sq.ft.f t ² f t 0.3 M BATH
Default(8 lbs/sq.ft.f t ² f t 0.3 M WIC 2
Default(8 lbs/sq.ft.f t ² f t 0.3 M HALL
Default(8 lbs/sq.ft.f t ² f t 0.3 LIVING RM
Default(8 lbs/sq.ft.f t ² f t 0.3 FOYER/DINING
Default(8 lbs/sq.ft.f t ² f t 0.3 KITCHEN
Default(8 lbs/sq.ft.f t ² f t 0.3 LAUNDRY
Default(8 lbs/sq.ft.f t ² f t 0.3 BEDROOM 3
Default(8 lbs/sq.ft.f t ² f t 0.3 BATH 2
Default(8 lbs/sq.ft.f t ² f t 0.3 BEDROOM 2
Default(8 lbs/sq.ft.f t ² f t 0.3 WIC 2
Default(8 lbs/sq.ft.f t ² f t 0.3 BATH 3
Default(8 lbs/sq.ft.f t ² f t 0.3 HALL
Default(8 lbs/sq.ft.f t ² f t 0.3 CLST 3
3/11/2021 11:06 AM EnergyGauge® USA 7.0.00 - FlaRes2020 FBC 7th Edition (2020) Compliant Software Page 7 of 7
FORM R405-2020 INPUT SUMMARY CHECKLIST REPORT
���������������������������������������������������������������������������
���������������������������������������������������������������������������������
�����������������������������������������������������