HomeMy WebLinkAboutDensity ReportUES Project No: Workorder No: Report Date: 3310.2100094.0000 232991-1 05/11/2021 607 Northwest Commodity Cove, Port St. Lucie, FL 34986 - P: 772-924-3575 - F: 772-924-3580 In-Place Density Test Report Client:United Teleports UES Technician:Amber Evans 19000 NE 5th Avenue Miami, FL 33179 Date Tested:05/04/2021 Project:CMT United Teleports Satellite Antenna 10161 Range Line Road,Port Saint Lucie, County, FL 34987 Type of Test: Area Tested:Furthest most East Intena pad Field:ASTM D-2937 Drive Cylinder Method Material:Native Laboratory:ASTM D1557 Modified Proctor Reference Datum:0 = Top of Final Grade The tests below meet the 98% minimum compaction requirement. Test No.Location of Test Range Maximum Density (pcf) Optimum Moisture (%) Field Dry Density (pcf) Field Moisture (%) Soil Compaction (%) Pass or Fail 1 SW side of pad 0-1 ft 112.2 11.1 110.3 10.5 98 Pass 2 NE side of pad 0-1 ft 112.2 11.1 111.6 9.3 99 Pass 3 Center of pad 0-1 ft 112.2 11.1 109.9 11.0 98 Pass Remarks:Permit # 21020139 Reviewed By GFA International, Inc FBPE Registry No.4930 John Kent Senior Project Engineer STATE OF FLORIDA Professional Engineer No. 63218 This item has been digitally signed and sealed by John Kent on the date adjacent to the seal. Printed copies of this document are not considered signed and sealed and the signature must be verified on any electronic copies. To establish a mutual protection to Universal's clients, the Public and ourselves, all reports are submitted as confidential property of our clients and authorization for publication of statements, conclusions or extracts from or regarding Universal's reports is reserved pending our written approval. Page 1