HomeMy WebLinkAboutEnergy CodeFORM R405-2020
FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION
Florida Department of Business and Professional Regulation - Residential Performance Method
Project Name: Lot 8 Block 1 Waterstone 1780 AGR
Builder Name: ADAMS HOMES
Street: 5428 Lugo Street
Permit Office:
City, State, Zip: Fort Pierce , FL , 34951
Permit Number:
Owner:
Jurisdiction: 661000
Design Location: FL, ST_LUCIE_CO_INTL
County: St. Lucie (Florida Climate
Zone 2 )
1. New construction or existing New (From Plans)
10. Wall Type41513.4 sqft.)
Insulation Area
2. Single family or multiple family, Detached
a. Concrete Block - Int Insul, Exterior
R=4.1 1245.40 ft2
3. Number of units, if multiple family 1
b. Frame - Wood, Adjacent
c. N/A
R=13.0 268.00 ft2
R= ft2
4. Number of Bedrooms 3
d. N/A
R= ft2
5. Is this a worst case? No
11. Ceiling Types (1900.0 sqft.)
Insulation Area
a. Under Attic (Vented)
R=30.0 1780.00 ft2
6. Conditioned floor area above grade (ft2) 1780
b. Knee Wall (Vented)
R=19.0 120.00 ft2
Conditioned floor area below grade (ft2) 0
c. N/A
R= ft2
7. Windows(177.0 sqft.) Description Area
12. Ducts
R ft2
a. U-Factor: Dbl, U=0.33 113.31 ft2
a. Sup: Attic, Ret: Main,. AH: Main
6 356
SHGC: SHGC=0'.23
b. U-Factor: Dbl, U=0.33 45.94 ft2
13. Cooling systems
kBtu/hr Efficiency
SHGC: SHGC=0.21
a. Central Unit
28.4 SEER:15:00
c. U-Factor: Dbl, U=0.55' 17.78 ft2
SHGC: SHGC=0.70
Area Weighted Average Overhang Depth: 2.639 ft.
14. Heating systems
kBtu/hr Efficiency
Area Weighted Average SHGC: 0.272
a. Electric Heat Pump
28.2 HSPF:8.50
8: Skylights Area
c. U-Factor:(AVG) N/A ft2
15. Hot water systems
SHGC(. : N/A
a. Electric
Cap: 40 gallons
9. Floor Types (1780.0 sqft.) Insulation Area
EF: 0.940
a. Slab -On -Grade Edge Insulation R=0.0 1780.00 ft2
b. Conservation features
b. N/A R= ft2
None
c. N/A R= ft2
16. Credits
Pstat
Glass/Floor Area: 0.099 Total Proposed Modified Loads: 52.62
PASS
Total Baseline
Loads: 52.75
I hereby certify that the plans s ications covered
this calculation are in compl' the Flori
ev of the plans and
"BE STD
rgy
specifications covered by this
Code.
calculation indicates compliance
with the Florida Energy Code.
PREPARED BY:
Before construction is completed
DATE: 01_na-21121 lnfinn Kanmany
this building will be inspected for
compliance with Section 553.908;<'
I hereby certify that this building, as designed, is in compliance
Florida Statutes.
j �5,,. ;
with the Florida E ode.
OWNER/AGENT: 1 -
BUILDING OFFICIAL:
DATE:
DATE:
-- Compliance requires certification by the air handler unit manufacturer that the air handler enclosure qualifies as
V certified factory -sealed in accordance with R403.3.2.1.
- Compliance requires an Air Barrier and Insulation In Checklist in accordance with R402.4.1.1 and this project requires an
envelope leakage test report with envelope leakage no greater than 7A0 ACH50 (R402.4.1.2).
- Compliance with a proposed duct leakage Qn requires a Duct Leakage Test Report confirming duct leakage to outdoors,
tested in accordance with ANSI/RESNET/ICC 380, is not greater than 0.055 Qn for whole house.
3/8/2021 4:28 PM EnergyGauge® USA 7.0.06 - FlaRes202O FBC 7th Edition (2020) Compliant Software Page 1 of 4
1 , FORM R405-2020
INPUT SUMMARY CHECKLIST REPORT
PROJECT
Title:
Lot 8 Block 1 Waterstone 178 Bedrooms: 3
Address Type:
Street Address
Building Type:
User
Conditioned Area: 1780
Lot #
8-1
Owner Name:
Total Stories: 1
Block/Subdivision:
Waterstone
# of Units:
1
Worst Case: No
PlatBook:
Builder Name:
ADAMS HOMES
Rotate Angle: 0
Street:
5428 Lugo Street
Permit Office:
Cross Ventilation: No
County:
St. Lucie
Jurisdiction:
661000
Whole House Fan: No
City, State, Zip:
Fort Pierce ,
Family Type:
Detached
FL, 34951
New/Existing:
New (From Plans)
Comment:
CLIMATE
/
Design Temp
Int Design Temp
Heating
Design Daily Temp
V
Design Location TMY Site
97.5 % 2.5 %
Winter Summer
Degree Days
Moisture Range
FL, ST LUCIE_CO_INTL FL_VERO_BEACH_MUNI
39 90
70 75
299
58 Medium
BLOCKS
Number Name Area Volume
1
Blockl 1780 15664
SPACES
Number Name Area Volume Kitchen Occupants
Bedrooms InfilID Finished
Cooled Heated
1
Main 1780 15664
Yes 4
3 1
Yes
Yes Yes
FLOORS
# Floor Type Space Perimeter R-Value
Area
Tile Wood Carpet
1 Slab -On -Grade Edge Insulatio Main 155.7 ft 0
1780 ft2 ---- 0.38 0 0.62
ROOF
/
Roof
Gable Roof
Rad Solar
SA Emitt
Emitt Deck Pitch
V
# Type Materials Area
Area Color
Barr Absor. Tested
Tested Insul. (deg)
1 Gable or Shed Composition shingles 1990 ft2
446 ft2 Medium
N 0.85
N 0.85
No 0 26.57
ATTIC
/
V
Type Ventilation
Vent Ratio (1 in)
Area RBS
IRCC
1 Full attic Vented
300 1780
ft2 N
N
CEILING
# Ceiling Type Space
R-Value Ins Type Area
Framing Frac
Truss Type
1 Knee Wall (Vented) Main
19 Batt
120 ft2
0.11
Wood
2 Under Attic (Vented) Main
30 Blown
1780 ft2
0.11
Wood
3/8/2021 4:28 PM EnergyGauge® USA 7.0.00 - FlaRes202O FBC 7th Edition (2020) Compliant Software Page 2 of 4
FORM R405-2020 INPUT SUMMARY r.W1=rKI IRT RFpnRT
WALLS
Adjacent
Space
Cavity Width
-
Height
Sheathing Framing Solar Below
o
1 SE Exterior Concrete Block - Int Insul
Main
4.1 40 0 8
0
320.0 ft'
0
0 0.6
0
2 SW Exterior Concrete Block - Int Insul
Main
4.1 40 6 8
0
324.0 ft'
0
0 0.6
0
3 W Exterior Concrete Block - Int Insul
Main
4.1 3 0 9
6
28.5 ft'
0
0 0.6
0
4 NW Exterior Concrete Block - Int Insul
Main
4.1 11 10 9
6
112.4 ftZ
0
0 0.6
0
5 N Exterior Concrete Block - Int Insul
Main
4.1 3 0 9
6
28.5 ftz
0
0 0.6
0
6 NE Exterior Concrete Block - Int Insul
Main
4.1 54 0 8
0
432.0 ft'
0
0 0.6
0
7 - Garage Frame - Wood
Main
13 33 6 8
0
268.0 ft'
0
0.23 0.01
0
DOORS
# Ornt Door Type Space
Storms
U-Value
Width
Height
Area
Ft In
Ft In
1 NW Insulated Main
None
.25
3
6 8
20 ft'
2 - Wood Main
None
.46
2
8
6 8
17.8 ft'
WINDOWS
Orientation shown is the entered, Proposed orientation.
/ Wall
Overhang
# Ornt ID Frame Panes NFRC
U-Factor SHGC Imp
Area
Depth
Separation
Int Shade
Screening
1 SE 1 Metal Low-E Double
Yes
0.55 0.7. N
17.8 ftZ
14 ft 4 in
0 ft 10 in
None
None
2 SE 1 Vinyl Low-E Double
Yes
0.33 0.23 N
32.4 ft'
1 ft 4 in
0 ft 10 in
Drapes/blinds
None
3 SW 2 Vinyl Low-E Double
Yes
0.33 0.23 N
32.4 ft'
1 ft 4 in
0 ft 10 in
Drapes/blinds
None
4 W 3 Vinyl Low-E Double
Yes
0.33 0.21 N
11.4 ft'
1 ft 4 in
0 ft 10 in
Drapes/blinds
None
5 NW 4 Vinyl Low-E Double
Yes
0.33 0.21 N
23.2 ft'
1 ft 4 in
0 ft 10 in
Drapes/blinds
None
6 N 5 Vinyl Low-E Double
Yes
0.33 0.21 N
11.4 ft'
1 ft 4 in
0 ft 10 in
Drapes/blinds
None
7 NE 6 Vinyl Low-E Double
Yes
0.33 0.23 N
48.6 ft'
1 ft 4 in
0 ft 10 in
Drapes/blinds
None
GARAGE
# Floor Area Ceiling Area
Exposed Wall Perimeter
Avg. Wall Height
Exposed Wall Insulation
1 591 ft' 591 ft'
64 ft
8 ft
1
INFILTRATION
# Scope Method SLA
CFM 50 ELA EgLA
ACH
ACH
50
1 Wholehouse Proposed ACH(50) .000391
1827.5 100.26 188.23
.1312
7
HEATING SYSTEM
# System Type Subtype
Speed Efficiency
Capacity
Block
Ducts
1 Electric Heat Pump/ Split
Sing] HSPF:8.5
28.2 kBtu/hr
1
sys#1
3/8/2021 4:28 PM EnergyGauge® USA 7.0.00 - FlaRes2020 FBC 7th Edition (2020) Compliant Software Page 3 of 4
FORM R405-2020 INPUT SUMMARY CHECKLIST REPORT
COOLING SYSTEM
# System Type
Subtype
Subtype Efficiency Capacity
Air Flow _
SHR
Block
Ducts
1 Central Unit/
Split
Singl SEER: 15 28.4 kBtu/hr cfm
0.75
1
sys#1
HOT WATER SYSTEM
# System Type
SubType
Location
EF Cap Use
SetPnt
Conservation
1 Electric
None
Garage
0.94 40 gal 62.3 gal
120 deg
None
SOLAR HOT WATER SYSTEM
FSEC
Collector
Storage
Cart # Company Name
System Model .# Collector Model
# Area
Volume
FEF
None None
ft2
DUCTS
/ ---- Supply ----
---- Return ---- Air
CFM 25
CFM25
HVAC #
# Location R-Value Area
Location
Area Leakage Type Handler
TOT
OUT
QN
RLF
Heat Cool
1 Attic
6 356 ftZ_
Main
89 ft? . Proposed Qn Main
--- cfm
97.9 cfm 0.06 0.60
1 1
TEMPERATURES
Programable Thermostat: Y
Ceiling Fans:
Cooling ] Jan Feb
Heating X] Jan X Feb
Venting Jan Feb
Mar
f X� Mar
A r
APr
Aug
May Jun Jul Au
Ma rl Junrl Jul ri
Sep
Sepp
rl
Oct
Oct
Nov
Nov
HX
Dec
Dec
[ ] [
X Mar
[
A r [
Ma Jun JulAug
Se
W
Oct
Nov
Dec
Thermostat Schedule: HERS 2006 Reference
Hours
Schedule Type
1
2
3
4 5 6 7
8
9
10
11
12
Cooling (WD) AM
PM
78
80
78
80
78
78 78 78 78
78
80
80
80
80
78
78 78 78 78
78
78
78
78
78
Cooling (WEH) AM
PM
78
78
78
78
78 78 78 78
78
78
78
78
78
78
78
78 78 78 78
78
78
78
78
78
Heating (WD) AM
PM
66
68
66
66
66 66 68 68
68
68
68
68
68
68
68
68 68 68 68
68
68
68
66
66
Heating (WEH) AM
PM
66
68
66
68
66
66 66 68 68
68
68
68
68
68
68
68 68 68 68
68
68
68
66
66
MASS
Mass Type
Area
Thickness Furniture Fraction
Space
Default 8 Ibs/s .ft.
0 ft2
Oft
3/8/2021 4:28 PM EnergyGaugeO USA 7.0.00 - FlaRes202O FBC 7th Edition (2020) Compliant Software Page 4 of 4
FORM R405-2020
ENERGY PERFORMANCE LEVEL (EPL) DISPLAY CARD
ESTIMATED ENERGY PERFORMANCE INDEX* = 100
The lower the EnergyPerformance Index, the more efficient the home.
5428 Lugo Street, Fort Pierce, FL, 34951
1. New construction or existing
New (From Plans)
10. Wall Type and Insulation
Insulation
Area
2. Single family or multiple family
Detached
a. Concrete Block - Int Insul, Exterior
R=4.1
1245.40 ftZ
3. Number of units, if multiple family
1
b. Frame - Wood, Adjacent
R=13.0
268.00 ftZ
c. N/A
R=
ftZ _
4. Number of Bedrooms
3
d. N/A
R=
ftZ
5. Is this a worst case?
No
11. Ceiling Type and insulation level
Insulation
. Area
a. Under Attic (Vented)
R=30.0
1780.00 ftZ
6. Conditioned floor area (ftZ)
1780
b. Knee Wall (Vented)
R=19.0
120.00 ftZ
7. Windows- Description
Area
c. N/A
R=
ftZ
a. U-Factor: Dbl, U=0.33
113.31 ftZ
12. Ducts, location & insulation level
R ftZ
SHGC: SHGC=0.23
a. Sup: Attic, Ret: Main, AH: Main
6 356
b. U-Factor: Dbl, U=0.33
45:94 ftZ
SHGC: SHGC=0.21
13. Cooling systems
kBtu/hr
'Efficiency
c. U-Factor: Dbl, U=0.55
17.78 ftZ
a. Central Unit
28.4 SEER:15.00
SHGC: SHGC=0.70
d. U-Factor: N/A
ftZ
SHGC:
14. Heating systems
kBtu/hr
Efficiency
Area Weighted Average Overhang Depth:
2.639 ft.
a. Electric Heat Pump
28.2
HSPF:8.50
Area Weighted Average SHGC:
0.272
8. Skylights Description
Area
15. Hot water systems
a. U-Factor(AVG): N/A
ttZ
a. Electric
Cap:
40 gallons
SHGC(AVG): N/A
EF: 0.94
b. Conservation featuresNone
9. Floor Types
Insulation
Area
a. Slab -On -Grade Edge Insulation
R=0.0
1780.00 ftZ
Credits (Performance method)
Pstat
b. N/A
R=
ftZ
c. N/A
R=
ftZ
certify that this home has complied with the Florida Energy Efficiency Code for Building
Construction through the above energy saving features which will be installed (or exceeded)
in this home before final inspection. Otherwise, a new EPL Display Card will be completed
based on installed Code compliant'features.
Builder Signature: Date:
Address of New Home: City/FL Zip:
*Note: This is not a Building Energy Rating. If your Index is below 70, your home may qualify for energy efficient
mortgage (EEM) incentives if you obtain a Florida Energy Rating: For information about the Florida Building Code,
Energy Conservation, contact the Florida Building Commission's support staff.
**Label required by Section R303.1.3 of the Florida Building Code, Energy Conservation, if not DEFAULT.
3/8/2021 4:28 PM EnergyGauge® USA 7.0.00 - FlaRes202O FBC 7th Edition (2020) Compliant Software Page 1 of 1