November 28, 2011
TO: Whom It. May Concern
-.FROM:. ' Alexis Spyrou, P.E.
Registered Florida Professional Engineer #68101 .
PRODUCT.
NAME: Flood Vents
MANUFACTURER,: Smart Vent Products, Inc.
450 Andbro Dr: Unit 1
Pitman, N108071
Dear Sir (Madam),
To the best of my knowledge, -the above -mentioned product
conforms to the 2010
edition of the Florida Building Code.
Please note'that I do not have, nor will I acquire, a financial interest in any company
Manufacturing or distributing the. prod uct(s) for which the reports are being issued. .
I also do not have, nor will l acquire, any financial interest with the Laboratory that
performed the test(s), or with the Engineer witnessing the test(s) and sealing the.test
report(s).:
%%` *fig Spy
j:
R0 .,�. '.
���•X, .E
Respectfully submitted Q':'�,t� NSF•. , .,.
•�
ALEX S,PYROU
..�`
.•� No 0.
:*
2011.12114.
15.18. 37�=='
:-P TATE of%
:. -
�O N'A' E \.
Alexis Spyrou, P.E.
Florida Registered.Professionai Engineer#68101.
Page 1 of 1 .
JUN, 0.2 2015
.. HITTING
5?. Uicic) County, FL
9 7 5•"��pT���7
7
t '; 'fir ..:. 4 �. ` '.,-"'•^�
High Efficiency Insulai
Superior Automatic Floc!
IMES Evaluated and i
FEMA Accepted Foundation Flood Vents
■ Potential savings'on.homeo, wher's NFIP premiums
■ Preserves aesthetic beautyof a.home l y requirin
2/3 less vents
® Each vent certified to protect 200. sq. ft.
of your home
/One 16".x 8" vent is certified to cover 200 square
.feet of enclosed area for flood protection
The insulated flood ventmodel is certified to provide.insulated
flood protection only. This model is used for a garage.or
condition w ere flood rotection is-riNglWi6Put
ation IS NU I aesIRM.Me Tj000.aoor is constructed OT solid
s ai. see . e around an insulating fo W,�,�,
MI
i Code Compliant, FEMA accepted,
ICC-ES Evaluated J��
■ All Stainless Steel construction. meets or exceeds z ZOi
flood and corrosion resistance code requirements' PEF?MITT«y�
• Patented automatic floats release bi-directional St• Lucre county, rL. .
flood door
■ Great for conditioned or sealed crawl spaces SMART. -VENT
www.smartvent.com 877-441-8368
"
s
s .1 t l•
�6
M �{
#,
Overhead/Garage Door Flood Vent
Dual Function SMART VENT° and Insulated FLOOD VENT
IMES Evaluated and
FEMA Accepted Foundation Flood Vents
■ Potential savings on homeowners NFIP premiums
■ Preserves aesthetic beiauty:of'a home by
requiring Z3 less vents
■ Each vent certified to protect 200 sq. ft.
of your home -
® Code Compliant, FEMA accepted,
IMES Evaluated
®. All Stainless Steel construction meets or exceeds;
.flood and corrosion resistance code requirements
® Patented. automatic floats release
bi-directional flood door
■Temperature controlledl louvers on dual function
models automatically open iin warm weather and
close in cold weather
One 16" x 8" vent is certified to cover 200 square
feet of enclosed area for flood.protection
The Overhead Door Model can be installed into a standard
garage door, providing 200 square feet of flood protection per
vent. A typical garage (less than 600 sq/ft) requires only three
vents in total to become compliant with the NAP requirements
and building codes. Two sizes are available depending on the
size of the panel.
wwm smarWent.com 877-441-8368
r yy ✓ Y'+v a' NV W.+, :.
Model #: 1540-'520
i
r,ij�fi. 'emu, .,
Installation Type: MasonryWall
Style: Insulated
.Dimensions:. 16" x 8"
F
Rough Opening: 16'/a" x 8'Y4" (one block; or CMIJ)
Finish: Stainless Steel (Standard)
Available Powder Coat Colors For Special Order: ,
t i f. � •} �6 � 1 l C d �°
White Wheat Gray Black Stainless (staridard)
Optional Accessories: .
Fire.Damper, InteriorTrim Flange&.Inner Sleeve, Rain Shield!
Other Models Available: SMART VENT® Dual Function Ventilat-
ing Flood Vent, Overhead Garage' Door Model, Stacked and Quad
Configurations, Models for Wood Studded Wall Applications and
Pour in Place Buck Systems.
.There's more online. at wwvy.smaitventxom
Dealer Locator, Installer Locator,!Cad Drawings,. Installation
Instructions, Technical Specifications; Frequently Asked
Questions, Videos, Testimonials, Resource Library Database,
Insurance Forms.
V
".
si^`Y
3 g fi
r
Rapidly rising floodwater can put extreme pressure on the foundation walls
causing imp roperlyvented structuiestoibuckle and collapse. SMAR, VENTS®
quickly and efficiently equalize the'pressure and minimize damage. '
www.smartvent.com • 877
How it works:
Flood Protection: The.FL00D VENT door is latched
closed until floodwater enters.. Entering floodwater
lifts the patented internal floats which unlatches and
rotates the door open. This allows the flood water
to automatically enter and:exitthrough the frame
opening, relieving the pressure from yourfoundation.
Use Fewer Vents
Preserve the aesthetic beauty of a home by requiring
24fewer vents. Each SMART VENT° protects 200 sq/ft
of enclosed area vs. 60 sq%ft for non -compliant vents.
How does one of your vents
provide so much. coverage?
You may have heard that FEMA requires thatflood
openings provide one square inch of opening per one
square foot.of enclosed area, referring to dimensions
of the opening in -proportion to the space to be vented.
This_is only partially. correct. FEMAs regulations and
guidelines do state that a non -engineered flood vent
solution must (among other requirements) provide one
square inch of opening per square foot of enclosed
area to be vented. However; all SMART VENT®
products are ICC-ES certified engineered openings.
They have. been designed,.engineered, tested, rated,
and certified to provide flood relief so. efficiently that
only one unit is needed for 200 square feet of enclosed
area. It would be our.pleasureto contact your code
official; surveyor, or insurance agent if they require
more information.
-441-8368
1'
Choose the correct model:
Along with the options for size, We also offer two.
model choices. The first is a dual function- model that
will.give you automatic flood protection along with .
automatic ventilation. This model only comes in 16" x .
8" size., The second is our Insulated 'model that seals
outth.e cool or warm air, but opens as flood water
rises. This model comes in both'siies.
Retrofitting
Easy installation (all hardware is included) makes this
model ideal to -retrofit into an existing garage door.
A'stainless steel -frame cleanly installs into the -door
with -only four (supplied) stainless steel.scr_ ews and-;
nuts.
How it works:.
Flood Protection: The SMART VENT® dooris°latched
closed until flood water.enters: Entering flood water
lifts the patented internal floats which unlatches and .
rotates the door open. This allows the flood water. .
to. automatically.enter.and exitthrough the frame
opening; relieving the pressure.from your foundation
walls.
Ventilation: A bimetal coil,(like a thermostat; no
electricity is:needed) automatically opens and: closes
the ventilation louvers as temperature changes: They
will be closed when it.is freezing outside and open
when it is warm outside.to provide natural ventilation.
TMga § ar 31'�i. 7#-rr�.r,�.�uz y
- o ;ram Y� r r't �r � t � .7;
Y s.
E
r_
r. 1 s 1.• , ,.. i f
1540.514 Dual Function SMART VENT® 555
1540-524,1540-574'Insulated Flood Vent
Installation Type: ;Overhead Garage Doors
Style: ;Louvered or Insulated
2 Sizes Available:
Dimension: :16":z 8" 0540=514,1540-524)
Rough Opening: -16".x 8" (cat. through door)_
Dimension: 14.%2" x.8%s".(1540-574)
Rough Opening: :1.4'%2" x 8 34"
Finish: Powder Coated Painted Whiter .
Available Powder Coat Colors Fbr Special Order:
Wheat. Gray Black Stainless Whife
Other Models. Available: SMART VENT® Dual Function V6, htilat-
ing Flood Vent, Insulated FLOOD VENT, Overhead Garage iDoor
Model, Stacked and Quad Confi;gur.ations, Models for Wood
Studded Wall Applicationsiand Pour in Place Buck Systejns.
There's more online at wwwsmartvent.com
Dealer Locator, Installer.Locator, Cad,Drawings, Installation. In-. .
structions, Technical Specifications; Frequently Asked Questions,
Video, Testimonials,. Resource. Library Database; Insurance' Forms.
Overhead -garage doors require flood protection too. Hydrostatic pressure I
caused by rapidly rising flood waters can easily destroy the average garage,door.
.
wwwwartvent.com • 877-441-8368: