Loading...
HomeMy WebLinkAboutReview CommentsJoe Cido From: Joe Cicio Sent: Monday, June 08, 2015 3:07 PM To: Chester Edwards (fivestarhousing@att.net); Dennie New (dennie@dennienew.com) Cc: Joe Cicio; Edward Roseberry Subject: Re -Review Comments for Permit Number 1504-0272 Attachments: Report_FL_Review_Comments_Noncompliantjrf.pdf Second Review Please Note: Florida has very broad public records laws. Most written communications to or from County officials regarding County business are public records available to the public and media upon request. It is the policy of St. Lucie County that all County records shall be open for personal inspection, examination and / or copying. Your e-mail communications will be subject to public disclosure unless an exemption applies to the communication. If you received this email in error, please notify the sender by reply e-mail and delete all materials from all computers. Planning & Development Services Building & Code Regulation Division 2300 Virginia Avenue Fort Pierce, FL. 34982 Phone:(772)462-2172 Fax:(772)462.6443 PROPERTY INFORMATION Address: 10701 S Ocean Dr 827 City / State / Zip: Jensen Beach, FI 34957 Parcel #: 4511-510-0028-000/9 Zoning: HIRD APPLICATION INFORMATION Permit Number: 1504-0272 Permit Type: SLAB ONLY CONTRACTOR INFORMATION Contractor Name: Dennie H New Business Name: Dennie H New Construction Co Business Addr: 7194 Sw Busch St City / State / Zip: Palm City, FI 34990-5562 REVIEWS AND COMMENTS Review Tvae DOCUMENTS MISSING 4/20/2015 Comment: FRONT COUNTER REVIEW Comment: PE REVIEW COMMENTS (2) Comment: 5/4/2015 Comment: 5/4/2015 5/4/2015 Comment: Comment: 6/8/2015 REVIEW COMMENTS 1 Owner(s): Andrew M Fodi / Michele M Fodi Jurisdiction: SAINT LUCIE COUNTY Lot#: 827 Block: Stories: Automatic Sprinkler System? No Fax Number: 772-220-2439 Status Reviewed By Date Started PENDING Lashahna Ingram 4/14/2015 SIGNATURE PAGE WITH TWO NOTARIZED SIGNATURES. COMPLETE Lashahna Ingram 4/14/2015 INCOMPLETE Joe Cicio 6/8/2015 Email: Dennie@Dennienew.Com Date Completed Date Released 4/14/2015 4/14/2015 SHOW THE DETAIL FOR THE REQUIRED UNDER FLOOR ACCESS * SEE FBCR408.4 ** SECOND REVIEW ** PLANS SHOW A 32" X 32" ACCESS PANEL / FBCR 408.4 ONLY REQUIRES A 16" X 24" / PLANS MUST SHOW A BOND BEAM / LINTEL DETAIL BRIDGING THE OPENING * STILL HAVE NO SPECS OR PRODUCT APPROVAL FORTH E ACCESS PANEL DESIGN PROFESSIONAL TO CHECK THE SIMPSON MASB [ MUDSILL ] ANCHORS AS SPECIFIED ON PLANS / THEY DO NOT APPEAR TO BE HOLDING DOWN THE MODULAR HOME AS THE HOME IS BEING SET ON TOP OF A DOUBLE 2" X 8" CONT. BAND ** ENGINEER TO DESIGN THE CENTER TO CENTER DIMENSIONS FOR THE PERIMETER STRAPPING ON PLANS ** ARCHITECT TO DESIGN THE REQUIRED UP -LIFT AND LATERAL LOADS IMPOSED ON THE ANCHORS ON PLANS * DESIGN PROFESSIONAL TO SPECIFY FOUNDATION NOTE 1 ON PLANS [ SUBMIT MANUFACTURERS SPECIFICATIONS W/ CONNECTING HARDWARE TO CONFORM WITH THE REQUIRED 4725 LB UP -LIFT CAPACITY **** ALL PERIMETER STRAPPING HAS BEEN ELIMINATED FROM THIS PERMIT / SHOW A DETAIL FOR THE MATE LINE STRAPPING PIER EMBED LENGTHS AND TIES TO MODULAR FRAME **** DESIGN PROFESSIONAL TO SHOW A PLAN DETAIL FOR THE ENTRY STAIRS ATTACHED TO THE STEMWALLS W/ CLOSED RISERS AND GRASPABLE HANDRAILS SECOND REVIEW CONTINUED **** PLANS SHOW 12" X 14" HYDRO VENTS / SMART VENTS SPECIFIED ARE 16" X 8" * SHOW THE [ 3 ] LOCATIONS ON PLAN FOR THE DUAL FUNCTION VENTS [ HYDRO AIR VENTILATION ] WITHIN 3 FEET OF EACH CORNER OF THE BUILDING * OTHER LOCATIONS ARE O.K. / SUBMITTED SPECS FOR AN OVERHEAD DOOR ??? * CANNOT CUT A VENT INTO A SWING DOOR UNLESS TESTED AS SUCH / ENCLOSED ENTRY MUST BE VENTILATED ON BOTH SIDES OF THE LOWER LANDING W/ DUAL FUNCTION VENTS AND NOT THROUGH THE DOOR L Planning & Development Services Building & Code Regutatlon Division 2300 Virginia Avenue Fort Pierce, FL. 34982 Phone:(772)462 2172 Fax:(772)462.6443 6/8/2015 Comment: Comment: 6/8/2015 6/8/2015 Comment: 6/8/2015 Comment: PLANS EXAMINER REVIEW Comment: ZONING REVIEW Comment: REVIEW COMMENTS 2 SHOW THE LOCATIONS AND SPACINGS ON PLANS FOR THE GROUND ANCHORS AS STATED IN FOUNDATION NOTE #9 * SHOW ALL ANCHORS AND STRAPPING * WIND LOAD SHEETS ARE INCOMPLETE AND / OR INCORRECT * WE ARE CURRENTLY ENFORCING THE 2012 SUPPLEMENTS [ LINE 1 ] * LINE [ 3 ] RISK CATEGORY MUST BE FILLED OUT * LINE [ 4 ] ASD OR LRFD / END ZONE WIDTH ? / MRH ? / ROOF PITCH ? * ALL COMPONENTS AND CLADDING PRESSURES TO BE FILLED IN STATE THE LOCATIONS OF THE WALL SHEATHING, HANDRAILS ETC ON PLANS * THESE ITEMS REMAIN ON PLANS COMMENTS MAILED AND E-MAILED AS OF THIS DATE COMPLETE Joe Cicio 5/1/2015 6/8/2015 6l8/2015 COMPLETE Lydia Galbraith 4/20/2015 4/20/2015 4/20/2015