HomeMy WebLinkAboutReview CommentsJoe Cido
From:
Joe Cicio
Sent:
Monday, June 08, 2015 3:07 PM
To:
Chester Edwards (fivestarhousing@att.net); Dennie New (dennie@dennienew.com)
Cc:
Joe Cicio; Edward Roseberry
Subject:
Re -Review Comments for Permit Number 1504-0272
Attachments:
Report_FL_Review_Comments_Noncompliantjrf.pdf
Second Review
Please Note: Florida has very broad public records laws. Most written communications to or from County officials regarding County business are public records
available to the public and media upon request. It is the policy of St. Lucie County that all County records shall be open for personal inspection, examination and /
or copying. Your e-mail communications will be subject to public disclosure unless an exemption applies to the communication. If you received this email in error,
please notify the sender by reply e-mail and delete all materials from all computers.
Planning & Development Services
Building & Code Regulation Division
2300 Virginia Avenue
Fort Pierce, FL. 34982
Phone:(772)462-2172 Fax:(772)462.6443
PROPERTY INFORMATION
Address: 10701 S Ocean Dr 827
City / State / Zip: Jensen Beach, FI 34957
Parcel #: 4511-510-0028-000/9
Zoning: HIRD
APPLICATION INFORMATION
Permit Number: 1504-0272
Permit Type: SLAB ONLY
CONTRACTOR INFORMATION
Contractor Name: Dennie H New
Business Name: Dennie H New Construction Co
Business Addr: 7194 Sw Busch St
City / State / Zip: Palm City, FI 34990-5562
REVIEWS AND COMMENTS
Review Tvae
DOCUMENTS MISSING
4/20/2015 Comment:
FRONT COUNTER REVIEW
Comment:
PE REVIEW COMMENTS (2)
Comment:
5/4/2015
Comment:
5/4/2015
5/4/2015 Comment:
Comment:
6/8/2015
REVIEW COMMENTS
1
Owner(s):
Andrew M Fodi / Michele M Fodi
Jurisdiction: SAINT LUCIE COUNTY
Lot#: 827 Block:
Stories: Automatic Sprinkler System? No
Fax Number: 772-220-2439
Status Reviewed By Date Started
PENDING Lashahna Ingram 4/14/2015
SIGNATURE PAGE WITH TWO NOTARIZED SIGNATURES.
COMPLETE Lashahna Ingram 4/14/2015
INCOMPLETE Joe Cicio 6/8/2015
Email: Dennie@Dennienew.Com
Date Completed Date Released
4/14/2015 4/14/2015
SHOW THE DETAIL FOR THE REQUIRED UNDER FLOOR ACCESS * SEE FBCR408.4 ** SECOND REVIEW **
PLANS SHOW A 32" X 32" ACCESS PANEL / FBCR 408.4 ONLY REQUIRES A 16" X 24" / PLANS MUST SHOW A
BOND BEAM / LINTEL DETAIL BRIDGING THE OPENING * STILL HAVE NO SPECS OR PRODUCT APPROVAL
FORTH E ACCESS PANEL
DESIGN PROFESSIONAL TO CHECK THE SIMPSON MASB [ MUDSILL ] ANCHORS AS SPECIFIED ON PLANS
/ THEY DO NOT APPEAR TO BE HOLDING DOWN THE MODULAR HOME AS THE HOME IS BEING SET ON
TOP OF A DOUBLE 2" X 8" CONT. BAND ** ENGINEER TO DESIGN THE CENTER TO CENTER DIMENSIONS
FOR THE PERIMETER STRAPPING ON PLANS ** ARCHITECT TO DESIGN THE REQUIRED UP -LIFT AND
LATERAL LOADS IMPOSED ON THE ANCHORS ON PLANS * DESIGN PROFESSIONAL TO SPECIFY
FOUNDATION NOTE 1 ON PLANS [ SUBMIT MANUFACTURERS SPECIFICATIONS W/ CONNECTING
HARDWARE TO CONFORM WITH THE REQUIRED 4725 LB UP -LIFT CAPACITY **** ALL PERIMETER
STRAPPING HAS BEEN ELIMINATED FROM THIS PERMIT / SHOW A DETAIL FOR THE MATE LINE
STRAPPING PIER EMBED LENGTHS AND TIES TO MODULAR FRAME ****
DESIGN PROFESSIONAL TO SHOW A PLAN DETAIL FOR THE ENTRY STAIRS ATTACHED TO THE
STEMWALLS W/ CLOSED RISERS AND GRASPABLE HANDRAILS
SECOND REVIEW CONTINUED **** PLANS SHOW 12" X 14" HYDRO VENTS / SMART VENTS SPECIFIED ARE
16" X 8" * SHOW THE [ 3 ] LOCATIONS ON PLAN FOR THE DUAL FUNCTION VENTS [ HYDRO AIR
VENTILATION ] WITHIN 3 FEET OF EACH CORNER OF THE BUILDING * OTHER LOCATIONS ARE O.K. /
SUBMITTED SPECS FOR AN OVERHEAD DOOR ??? * CANNOT CUT A VENT INTO A SWING DOOR UNLESS
TESTED AS SUCH / ENCLOSED ENTRY MUST BE VENTILATED ON BOTH SIDES OF THE LOWER LANDING W/
DUAL FUNCTION VENTS AND NOT THROUGH THE DOOR
L
Planning & Development Services
Building & Code Regutatlon Division
2300 Virginia Avenue
Fort Pierce, FL. 34982
Phone:(772)462 2172 Fax:(772)462.6443
6/8/2015 Comment:
Comment:
6/8/2015
6/8/2015 Comment:
6/8/2015 Comment:
PLANS EXAMINER REVIEW
Comment:
ZONING REVIEW
Comment:
REVIEW COMMENTS
2
SHOW THE LOCATIONS AND SPACINGS ON PLANS FOR THE GROUND ANCHORS AS STATED IN
FOUNDATION NOTE #9 * SHOW ALL ANCHORS AND STRAPPING *
WIND LOAD SHEETS ARE INCOMPLETE AND / OR INCORRECT * WE ARE CURRENTLY ENFORCING THE
2012 SUPPLEMENTS [ LINE 1 ] * LINE [ 3 ] RISK CATEGORY MUST BE FILLED OUT * LINE [ 4 ] ASD OR LRFD /
END ZONE WIDTH ? / MRH ? / ROOF PITCH ? * ALL COMPONENTS AND CLADDING PRESSURES TO BE
FILLED IN
STATE THE LOCATIONS OF THE WALL SHEATHING, HANDRAILS ETC ON PLANS * THESE ITEMS REMAIN
ON PLANS
COMMENTS MAILED AND E-MAILED AS OF THIS DATE
COMPLETE Joe Cicio 5/1/2015 6/8/2015 6l8/2015
COMPLETE Lydia Galbraith
4/20/2015 4/20/2015 4/20/2015