Loading...
HomeMy WebLinkAboutRevisions; Flatwork Min 4inches from setback stem wallOFFICE USE OP DATE FILED: REVISION FEE: 1. 2. 3. 4. ADDRESS: PERMIT# \goy - o2`ta RECEIPT # PLANNING &DEVELOP CES BUILDING &CODE REG 2300VDIGINIAT - FORT PIERCE, FL772) 4 Bob (772) 462-1553 FAX (772) 462-1578 APPLICATION FOR BUILDING PERMIT REVISIONS PROJECT INFORMATION DETAILED DESCRIPTION OF PROJECT REVISIONS �itF\-k- %.4 cryyC1.'-N _ IA ` `-'C-o r,-, S<4A CONTRACTOR INFORMATION: STATE of FL REG./CERT. #: O GC BUSINESS NAME: h QUALIFIERS NAME: S ADDRESS: Qy gw G'wa< CITY: PHONE (DAYTIME): -X OWNER/BUILDER INFORMATION: NAME: 2r od", ADDRESS: 2 l 0 10! CrrY: eA. PHONE: ST. LUCIE COUNTY CERT. #: A L n . ZIP: O FAX: n-la aa0-2v39 5. ARCHITECT/ENGINEER INFORMATION: NAME: ADDRESS: CITY: STATE: ZIP: PHONE (DAYTIME): FAX: Revised 0722/2014 I AC ACRE A/C AIR CONDITIONER ALUM ALUMINUM ANC ANCHOR APPROX APPROXIMATE AVE AVENUE BRG BEARING BLK BLOCK BLVD BOULEVARD BLDG BUILDING BM BENCHMARK _ CAN CABLE TELEVISION BOX _ C CALCULATED CS CATCH BASIN A CENTRAL ANGLE CLF CHAINLINK FENCE CHO CHORD CONC CONCRETE CBS CONC. BLOCK STRUCTURE \ CM CONCRETE MONUMENT CNR COULD NOT READ CPP CONCRETE POWER POLE \ CDR CORNER COV COVERED CMP CORRUGATED METAL PIPE \ CVG CONCRETE VALLEY GUTTER - D DEED DDRAINFIELD DEE DRAINAGE EASEMENT - DRAINAGE FLOW ESMT EASEMENT EOC EDGE OF CONCRETE EDP EDGE OF WATER LOT 829 EM ELECTRIC METER ES ELECTRIC SERVICE ELEV ELEVATION ENOL ENCLOSURE X 17.00 EXISTING ELEVATION E e FT FIELD MEASUREMENT SET IB x�. R.T A � FNC FENCE zv. FFE FINISHED FLOOR ELEVATIONFH FIRE e S a N F AT FPL FLORIDAPOWER& LIGHT 4). S7 RANTPRUP�•k• I V �' N " FNO FOUND 6'` ej" J ,�44 erg Z- 1 L' GOVF GOVERNMENT °y �� `�T 2� 1SE HOUSE 1& E INGRESS & EGRESS EASEMENT ME . �` a J IBV IRON BAR <0e - ( A -...,6 ,�...... ..,,., 77 3C+ IP IRON PIPE l (>C) 1 IS & C IRON BAR & CAP �i \ �& d. -U � $�Q ••. +� Ak „6 M P & C : IRON IENGTH CAP Q>s' / '.I1 N t s ' t C. LE LANDSCAPE EASEMENT ( //�� 1f�'1"` LS LICENSED BUSINESS NUMBER j `4'� � ,I.,ac LP LIGHT POLE 91 p MAG W MAC HAIL NAIL & WASHER z, g L ��� ... M CS:.$,,,f e'a"L' ,'�,•. ME MAINTENANCE EASEMENT p SH�j MH MANHOLE .� cx �.T, Lr, ciceS"t' ��V"{E.� MFHWL MEAN METAL HFENCE Al1R UNE 1.Ak CONIC 31 1{' Pel-IC.'IrkirAl N & TT NAIL & TIN TAB �� y J 111, 827 ,. N & W NAIL '& WASHER 1 NOVO NATIONAL GEODETIC VERTICAL DATUM Q --"�' NO ID NO IDENTIFICATION �� O.�.°^�-.•;..,. �' QU _ NTS NOT TO SCALE NAD NORTH AMERICAN DATUM, ORBOF SET RECORD BOOK 90 OVERHANG OHW OVERHEAD WIRE PG PAGE PK PARKER-KALON NAIL PK & TT PARKER-KALON NAIL & TIN TAB PK & W PARKER-KALON NAIL & WASHERPAVEMENT PPMT PPERMANENT REFERENCE MONUMENT VERB,. NPVM7g•5 21yW PS PLATBOOK - . PCC POINT OF COMPOUND CURVATURE CONCRETECONIC. PC POINT OF CURVATURE SEAWALL PI POINT OF INTERSECTION RETAINING 'apt POB POINT OF BEGINNING WALL POC POINT OF COMMENCEMENT llir BIIILbtlVC" POE POINT OF ENCROACHMENT ,P PRC POINT OF REVERSE CURVATURE PT POINT OF TANGENCY - PI, POWER POLE LE , PRIVATE LE EASEMENT PLS PROFESSIONAL LAND SURVEYOR PROPERTY LINE PROP: PROPOSED �,,,.•^"'��� 17.00 PROPOSED ELEVATION PRO PRORATED R RADIUS 1T '7 A RAD RADIAL RRS RAILROAD SPIKE i�l;yi L LOT 825 RNG RANGE t - d RLS REGISTERED LAND SURVEYOR n RCP REINFORCED CONCRETE PIPE •\(J'v0 R/W RIGHT OF WAY ,S p SS SANITARY SEWER SECT SECTION \ SET LB. SET 5k/8 IRON BAR & CAP i4049 SSET PK SET PNAIL /T SEPTIC TANK &WASHER /4049 S/W SIDEWALK t' gNG• ,,,s SBT SOUTHERN BELL TELEPHONE BOX S/F SQUARE FEET .IECN S/D SUBDIVISON NT TOE TEMPORARY CONSTRUCTION EASEMENT GRAPHIC SCALE TOB TOP OF BANK TOE TOE OF SLOPE TWP TOWNSHIP 10 0 5 10 TRANS TRANSFORMER TYP TYPICAL E GE EASEMENT UTILITY EASEMENT UEAEN U/G UNDERGROUND WF WOOD FENCE ( IN FEET ) WM WATER METER ' WV WATER VALVE I inch = 10 IL. wP WOOD POWER POLE 0 DIAMETER iu 1'�RO�'ERT�` ADDRESS. �07I7I SOUTH OCEAN DRIVE827 2< CERTIFIED TO: — ANDREW FODI & MICHELE FODI FND 5/8- 0 RLS 1272 O.7'S0.74'W NM� I TRASH RECEPTACLE gkTV .e_ I Will on _% s I LOT 830 1 920 i 911 1 01T 016 ' I c22 ON W1 41C \ 015 elf i 71 22 1 4-A0 5 2 0tl Bli ICI 011 .- e LOCATION MAP FM 5/13 p a a IB & C PSM 4049 1h�j�.'FFr< fj� d � WP ? ! g LOT 828 LEGAL DESCRIPTION LOT 827, HOLIDAY OUT IN AMERICA AT ST. LUCIE, INC., SECTION "D", AS RECORDED IN PLAT BOOK 16, PAGE 24, PUBLIC RECORDS OF ST. LUCIE COUNTY, FLORIDA. FND 5/8" 0 IB & C LR 6301 0.0S S0.05' W FND 5/8" 0 IB & C LB 6301 OJO' W LOT 826 of R "tr Ir" / i \ LOT 824 \ 1 NOT VALID W17-HOUT THE SIGNATURE AND THE ORIGINAL RAISED SEAL OF A FLORIDA LICENSED SURVEYOR AND MAPPER. SOWN,,- INC SIEPHEN J. BR WN, NPR tO �,Ab"' T2Y YPIR AND MAPPER REGISTR �Q� -STATE OF i-LORIDA Y ' U e of field survey. Se � NOTE e/14/2014 1. Survey of description as furnished by Client. 2. Lands shown hereon were not abstracted for easements and/or rights —of —way of record. 3. All bearings are referenced to the Westerly line of subject property, platted as N17'12'18"W, all others relative thereto. 4. Elevations shown hereon are relative to North American ertical Datum of 1988, and are based on bench mark. 5. There gre no above ground encroachments, unless other 'se shown. 6. The Nefional Flood Insurance Program designation as indi ated on the FE*0.0- Map No- 122111C 0313J . dated 0211612012 locates the parcel in Zone AE . base flood elevation _ 8.0 feet; subject to any sEBling and interpolation factors associated with mapping of this accuracy. This data is an Interpretation by the surveyor and is provided as a codFlesy. The flood zone(s) should be verified by a determination agency. 7. Underyfpund foundations & utilities not located unless shown. REVISIONS BY (( �z \5 s� 1� OD 00 w CV /Q O LL L` W U) F-4-1 ZO a O w a LL_. Z If) � -v UI IT � q w 0 < U; L(I ,a LL U � a N r4 a z k7 UI 4 LLJ F-4 Cl) > z�A U] W 0 O V `- q / e ,D U) Q E-, n 04 [Wxj 1Z--••II H•L-•1 U) OM P-4 W W U) U) E- A 0) OD DRAWN S.J.B. CHECKED S.J.B. DATE 11 15 2014 SCALE 1" = 10' ,roe No. 4058-7 =01 SHEET ONE OF ONE SHEETS a - y i PER 32222. (1) 50. IN. FOR EACH 5Q, FT. Or - ENCLOSED AREA. EACH VENT COVERS 145 5Q. FT. PER PRODUCT APPROVAL. STRUCTURAL NOTES: S15 5Q. FT. / 145 = 6.12 1 VENTS REQUIRED ° SOIL BEARING CAPACITY MIN. 2500 PSF ALL STRUCTURAL CONCRETE SHALL DEVELOP PER 4052. EXCEPTION (1) 5Q. FT. 18.COMPRESSIVE STRENGTH OF 3000 PSI Afi PER 1500 SO. FT. OF FLOOR ARE ALL REINFORCING STEEL SHALL BE GRADE 60 WITH VAPOR BARRIER. MEETING ASTM SPECS A-615 ° MIN CONIC. PROTECTION FOR RE -BARS: (1) 50. FT. = 144 SQ. IN. FTGS: 3" BEAMS: III," SLABS: r' NET VENT AREAI5 &1 SQ. IN. LAP REINFORCING BARS 30 INCHES MINIMUM 144 / 61 = 3 VENTS lc %" STRUCTURAL SHEATHING —\ ALL WALL CAVITIES TO BE INSULATION FILLED VINYL LAP SIDING \ REMOVE BOTTOM ROW OF LAP, NOTCH LAP STARTER METAL, BEND UPLIFT STRAP UP STRUCT. SHEATHING ■ SECURE W/ (6) 10d NAILS (LEAVE LAP SIDING OFF UNTIL INSPECTION IS COMPLETE) INSTALL VINYL LAP SIDING AFTER INSPECTION 7 �J ■ ■ SXSXI6 CONCRETE MASONARY UNIT ■ ■ ■ ■ ■ 12Xi4 HYDRO VENT ■ INTERIOR WALL BOARD "I TYPICAL 2X6 EXTERIOR �- WALL CONSTRUCTION TYPICAL FLOOR DECKING �­ 2XIO FLOOR CONSTRUCTION AIR VENT CALCULATIONS FOR STEMUJALL VENTING: 12X14 VENT = 145 5Q. IN. HYDRO VENT CALCULI AC 41'X10'+48'XII'-6" = S15 SQ. FT. FOR STEMWALL VENTIN 1 SQ. FT. FOR EA. 150 SQ. FT. 'BID / 145 • 6.1 SQ. FT. 6.1 X 144" / 168 = 6b 12XI4 VENT = 145 SQ. IN. CV VENTS TOTAL REQ'D. 41'XI0'+48'XII'-6" = S15 SQ. FT. S15 SQ. IN. REQ'D, TOTAL VENT& c 1 ((1) NOTE: VENTS TOTAL REOV. t7 2 X �'+ A MINIMUM OF 4" OF CONCRETE FLATWORIK BE STEMWALL 0 PROPERTY LINE. (NOT TO EXCEED PROPERTY LINE.) 48'-04" e PROVIDE FOR 32X32 ACCESS DOOR PER R-4083 (NO LINTEL ABOVE) A a (2) 2X8 CONTINUOUS GALVANIZED TERMITE SHIELD 8X8XI6 KNOCK OUT BLOCK SIMPSON MASB ANCHOR TO COME OUT OF 3,000 P.S.I. CONCRETE FILLED TOP CORNER OF KNOCK OUT BLOCK W/ (U 5 BAR AS SHOWN 5 BAR TO BE CONTINUOUS AROUND TOP OF PERIMETER STEM WALL TYPICAL BXSXI6 CMU'8 SINGLE U-BLOCK W/ (1) 5 BAR (ll 5 ROD m 48" O.C. FILLED W/ CONCRETE TYPICAL SIMPSON MASK UPLIFT ANCHOR OR MONOLITHIC FOOTING: EQUAL s 32" O.C., 12" MIN, CORNER DISTANCE. 12"x12" W/ (2) 5 SEE SECTION A -A. 2 CELLS MIN. FILLED FROM G , BARS ON WIRE SADDLES KNOCK OUT BLOCK TO FOOTER W/ (1) 5 BAR CONTINUOUS ' FOUNDATION NOTE,5: 1501*01ETRIC DETAIL NOTE: ALL DETAILS ABOVE FOUNDATION PERTAIN TO MODULAR HOME C FAI 2. SEE ABOVE FOUNDATION PLAN FOR TIE -DOWN STRAP LOACTION AND SPACING. 3. ALL PIERS SHALL BE Iro" X fro" X 3211 MASONRY BLOCKS ON 24" X 24" X 12" CONCRETE FOOTER Q 4. MINIMUM SOIL BEARING CAPACITY IS 2,500 Ib, PSF. 5. IT WILL BE THE SITE CONTRACTORS RESPONSIBILITY TO INSURE THAT ALL GRASS, LOOSE DESBRIS, ETC. ARE REMOVED FROM UNDER THE BUILDING, AND THAT THE GROUND 15 LEVELED TO WITHIN roil. ro. ALL SOIL LOCATED UNDER FOOTINGS SHALL BE COMPACTED TO 95% DENSITY. 'T. WOOD SHIMS MAY BE INSTALLED WHEN NECESSARY, BETWEEN THE FLOOR AND THE TOP OF THE PIER SHIMS SHALL BE FREE OF KNOTS, CHECKS, SPLINTS, AND SIMILAR IMPERFECTIONS. SHIMS SHALL BE OF P.T. LUMBER AND BEARING AT ALL CONTACT POINTS SHALL NOT BE LESS THAN 2/3 OF THE BEARING PRIOR TO ADDING THE SHIMS, 8. NOTE MASONRY PIERS TO BE INSTALLED AS SHOWN. SIMPSON MASK STRAP (SEE 'SOMETRIC FOR SPACING) i SX8XI6 CMU'S MONOLITHIC FOOTING: 12"xl2" W1 (2) 5 BARS ON WIRE SADDLES CONTINUOUS n , SECTION A -A A SCALE: 3/4" = 1'-0" ,OUNIDATION ` ,. 41'-04" VENT VENT .VENT vsw VENT I 1 I2XI4 HYDRO/AIR VENT STEM WALL PER R-406.2 �> Q z I I MONOLITHIC FOOTING: MONOLITHIC ING: _ I .' } W/ (4) "5 BARS EACH WAY 12"xl2" W/ (2) 5 WSIRE DDLES I I'; COARSONICI UOUON I -01, - I I o I ro 1 �o �o . I-o I B j. o� Q I - o - J; L_ -__ o, ,o--_ o 0 I I 1 I AI -------- --__---- 1 4" CONCRETE SLAB (3000 PSU OVER 6" X 6" X 10/10 W.U.I.M. OR FIBRE MESH OVER p I 16X8 SMART VENT I 6 MIL POLYETHYLENE VAPOR BARRIER OVER MODEL 01540-510 _ CLEAN, POISONED, COMPACTED (TO 2500 PSF O - ----- O I OR 95% DENSITY) FILL. I C I l I to I I PROVIDE +4" CONCRETE CAP I OVER SLAB IN STAIR WELL I I FILLED CELLS m 4'-0" OC L I I- ---I----------------j L--— — — — — — — — — — — — — --------------� O O O O O ___ Oi IRA& 101 101 17 O Rm TIT) VENT A y�i B VENT VENT EN VENT MONOLITHIC FOOTING: S"x5" W/ (1) 5 BAR 48 -ID4 SIMPSON MASS ANCHOR TO COME OUT OF TOP CORNER OF KNOCK OUT BLOCK. 5 BAR TO BE CONTINUOUS AROUND TOP OF PERIMETER STEM WALL SINGLE U-BLOCK W/ (1) 5 BAR SXSXI6 CMU'S MONOLITHIC FOOTING: 4 12'xI2" W/ (2) 5 y, BARS ON WIRE SADDLES'. CONTINUOUS NOTE: �. A MINIMUM OF 4" OF CONCRETE QD FLATWORK BETWEEN STEMWALL d 0 PROPERTY LINE. (NOT TO EXCEED PROPERTY LINE-) SECT f O SCALE: 3/4" = 1'-0" VARIES (INCLUDES 3/8" SHEATHING BOTH SIDES t 1/4,, GAP BETWEEN HOMES) (FOUNDATION LENGTH TO BE HOME LENGTH PLUS 3/419 SCALE; 1/2" = I'-0" CT I Oil SECT101 SCALE: 3/4" = 1'-0" 1) PER 2010 FBC W1 2012 SUPPLEME 2) 3) CONSTRUCTION TYPE V 4) RISK CATEGORY II ULTIMATE DESIGN WIND 5P1= 5) EXPOSURE C DIAGONAL HATCHING DENOTES MONOLITHIC FOOTING: IS"Dx8"W W/ (2)'S BARS CONTINUOUS (FOR FUTURE IMPROVEMENT) (2) 2X8 PT CONTINUOUS (1) 5 ROD FILLED W/ CONCRETE STAGGER 6X8XI6 MASONRY UNITS AS SHOUBN MONOLITHIC FOOTING: M"x24"44" W1 (4) 5 BARS EACH WAY Scale: I = -0" � /4" I' ' z Drawn: Mh/BGM THIS SETUP HAS BEEN DESIGNED Job: FODI5 u, FOR A FLOOD ZONE INSTALLATION -' Sheet: -2