HomeMy WebLinkAboutAPPROVED FL 5V 26GA_1225_17679-R61/29/2021 Florida Building Code Online https://www.floridabuilding.org/pr/pr_app_dtl.aspx?param=wGEVXQwtDqvFGYZsjrZFR%2bP9kYGhInRHUPuiAxDRkQtoa%2fGVEztq%2bg%3d%3d 1/2 BCIS Home Log In User Registration Hot Topics Submit Surcharge Stats & Facts Publications Contact Us BCIS Site Map Links Search Product Approval USER: Public User Product Approval Menu > Product or Application Search > Application List > Application Detail FL #FL17679-R6 Application Type Revision Code Version 2020 Application Status Approved Comments Archived Product Manufacturer Drexel Metals, Inc. Address/Phone/Email 204 Railroad Drive Ivyland, PA 18974 (502) 303-1511 jshumate@drexmet.com Authorized Signature Jason Shumate jshumate@drexmet.com Technical Representative Address/Phone/Email Quality Assurance Representative Address/Phone/Email Category Roofing Subcategory Metal Roofing Compliance Method Evaluation Report from a Florida Registered Architect or a Licensed Florida Professional Engineer Evaluation Report - Hardcopy Received Florida Engineer or Architect Name who developed the Evaluation Report Zachary R. Priest Florida License PE-74021 Quality Assurance Entity Architectural Testing, Inc., an Intertek Company Quality Assurance Contract Expiration Date 12/31/2025 Validated By Locke Bowden P.E. Validation Checklist - Hardcopy Received Certificate of Independence FL17679_R6_COI_DRX15002.6 2020 FBC Eval Metal Roofing HVHZ final.pdf Referenced Standard and Year (of Standard)Standard Year ASTM B 117 2016 ASTM G 155 2013 TAS 100 1995 TAS 110 2000 TAS 125 2003 Equivalence of Product Standards Certified By Sections from the Code 1/29/2021 Florida Building Code Online https://www.floridabuilding.org/pr/pr_app_dtl.aspx?param=wGEVXQwtDqvFGYZsjrZFR%2bP9kYGhInRHUPuiAxDRkQtoa%2fGVEztq%2bg%3d%3d 2/2 Product Approval Method Method 1 Option D Date Submitted 08/09/2020 Date Validated 08/10/2020 Date Pending FBC Approval 08/20/2020 Date Approved 10/13/2020 Summary of Products FL #Model, Number or Name Description 17679.1 Drexel Metal Roofing Systems DMC 100NS, DMC 150SS, DMC 175S, DMC 200S, DMC 5V Limits of Use Approved for use in HVHZ: Yes Approved for use outside HVHZ: No Impact Resistant: N/A Design Pressure: +0/-180 Other: See evaluation report for limits of use. Installation Instructions FL17679_R6_II_DRX15002.6 2020 FBC Eval Metal Roofing HVHZ final.pdf Verified By: Zachary R. Priest PE-74021 Created by Independent Third Party: Yes Evaluation Reports FL17679_R6_AE_DRX15002.6 2020 FBC Eval Metal Roofing HVHZ final.pdf Created by Independent Third Party: Yes Back Next Contact Us :: 2601 Blair Stone Road, Tallahassee FL 32399 Phone: 850-487-1824 The State of Florida is an AA/EEO employer. Copyright 2007-2013 State of Florida. :: Privacy Statement :: Accessibility Statement :: Refund Statement Under Florida law, email addresses are public records. If you do not want your e-mail address released in response to a public-records request, do not send electronic mail to this entity. Instead, contact the office by phone or by traditional mail. If you have any questions, please contact 850.487.1395. *Pursuant to Section 455.275(1), Florida Statutes, effective October 1, 2012, licensees licensed under Chapter 455, F.S. must provide the Department with an email address if they have one. The emails provided may be used for official communication with the licensee. However email addresses are public record. If you do not wish to supply a personal address, please provide the Department with an email address which can be made available to the public. To determine if you are a licensee under Chapter 455, F.S., please click here . Product Approval Accepts: a CREEK Technical Services, LLC DRX15002.6 FL17679-R6 Page 1 of 4 Page 1 of 21 This evaluation report is provided for State of Florida product approval under Rule 61G20-3. The manufacturer shall notify CREEK Technical Services, LLC of any product changes or quality assurance changes throughout the duration for which this report is valid. This evaluation report does not express nor imply warranty, installation, recommended use, or other product attributes that are not specifically addressed herein. Certificate of Authorization No. 29824 17520 Edinburgh Dr Tampa, FL 33647 (813) 480-3421 EVALUATION REPORT FLORIDA BUILDING CODE, 7TH EDITION (2020) Manufacturer: DREXEL METALS, INC. Issued August 9, 2020 1234 Gardiner Lane Louisville, KY 40213 (502) 716-7143 www.drexmet.com Manufacturing: Drexel Metals Association of Regional Manufacturers (DM-ARM) Quality Assurance: Architectural Testing, Inc., An Intertek Company (QUA1844) SCOPE Category: Roofing Subcategory: Metal Roofing Code Edition: Florida Building Code, 7th Edition (2020) High-Velocity Hurricane Zones (HVHZ) Code Sections: 1518.9.1, 1523.1.1, 1523.6.5, 1523.6.5.2.4, 1523.6.5.2.4.1 Properties: Wind Resistance REFERENCES Entity Report No. Standard Year Architectural Testing (TST1558) 56840.02-122-18 TAS 100 1995 Architectural Testing (TST1558) 56842.02-122-18 TAS 100 1995 Architectural Testing (TST1558) 58461.01-122-44 TAS 125 2003 Architectural Testing (TST1558) 58641.02-122-44 TAS 100 1995 Architectural Testing (TST1527) H3245.01-450-18 TAS 125 2003 Architectural Testing (TST1527) H3245.02-450-18 TAS 100 1995 Architectural Testing (TST1527) H9058.02-450-18 TAS 125 2003 Architectural Testing (TST1527) H9058.01-450-18 TAS 125 2003 Architectural Testing (TST1527) H9058.03-450-18 TAS 100 1995 Hurricane Test Laboratory (TST1527) 0287-0209-07 TAS 125 2003 Hurricane Test Laboratory (TST1527) 0287-0308-07 TAS 125 2003 Hurricane Test Laboratory (TST1527) 0287-0311-07 TAS 125 2003 Hurricane Test Laboratory (TST1527) 0287-0312-07 TAS 125 2003 Hurricane Test Laboratory (TST1527) 0287-0313-07 TAS 125 2003 Hurricane Test Laboratory (TST1527) 0287-0512-07 TAS 125 2003 Hurricane Test Laboratory (TST1527) 0287-0706-07 TAS 125 2003 PRI Construction Materials Technologies (TST5878) VLS-005-02-01 ASTM B 117 TAS 110 2016 2000 PRI Construction Materials Technologies (TST5878) VLS-004-02-01 ASTM G 155 TAS 110 2013 2000 PRI Construction Materials Technologies (TST5878) DMC-002-02-01 TAS 100 1995 PRI Construction Materials Technologies (TST5878) DMC-004-02-01 TAS 125 2003 PRI Construction Materials Technologies (TST5878) DMC-005-02-01 TAS 125 2003 PRI Construction Materials Technologies (TST5878) DMC-006-02-01 TAS 125 2003 PRI Construction Materials Technologies (TST5878) DMC-007-02-01 TAS 100 1995 PRI Construction Materials Technologies (TST5878) DMC-008-02-01 TAS 100 1995 PRI Construction Materials Technologies (TST5878) DMC-009-02-01 TAS 100 1995 PRI Construction Materials Technologies (TST5878) DMC-014-02-01 TAS 125 2003 PRI Construction Materials Technologies (TST5878) DMC-016-02-01 TAS 100 1995 PRI Construction Materials Technologies (TST5878) DMC-030-02-01 TAS 100 1995 PRI Construction Materials Technologies (TST5878) HTL-013-02-01 TAS 100 1995 PRI Construction Materials Technologies (TST5878) HTL-014-02-01 TAS 100 1995 A CREEK Technical Services, LLC DRX15002.6 FL17679-R6 Page 2 of 4 Page 2 of 21 This evaluation report is provided for State of Florida product approval under Rule 61G20-3. The manufacturer shall notify CREEK Technical Services, LLC of any product changes or quality assurance changes throughout the duration for which this report is valid. This evaluation report does not express nor imply warranty, installation, recommended use, or other product attributes that a re not specifically addressed herein. DREXEL METALS, INC. Metal Roofing (HVHZ) PRODUCT DESCRIPTION DMC 100NS Profile: 1 in. snap lock seam; Max.16 in. coverage Description: Non-structural, snap lock standing seam roof panel with integral perorated nail strip Material: Min. 24 ga. Fluropon® coated ASTM A792 AZ50, or ASTM A653 G90; Fy = min. 50 ksi; Shall conform with FBC Section 1507.4.3 DMC 150SS Profile: 1.5 in. mechanical seam; Max. 16 in. coverage Description: Non-structural, mechanical lock standing seam roof panel Material: Min. 0.032 in. Fluropon® coated ASTM B209 aluminum; Fy = min. 16 ksi; Shall conform with FBC Section 1507.4.3 Min. 24 ga. Fluropon® coated ASTM A792 AZ50, or ASTM A653 G90; Fy = min. 50 ksi; Shall conform with FBC Section 1507.4.3 DMC 175S Profile: 1.75 in. snap lock seam; Max. 18 in. coverage Description: Non-structural, snap lock standing seam roof panel Material: 0.032-inch (Fy = min. 24 ksi) or 0.040-inch (Fy = min. 20 ksi) Fluropon® coated ASTM B209 aluminum; Shall conform with FBC Section 1507.4.3 Min. 24 ga. Fluropon® coated ASTM A792 AZ50, or ASTM A653 G90ASTM A792 or ASTM A653; Fy = min. 50 ksi; Shall conform with FBC Section 1507.4.3 A CREEK Technical Services, LLC DRX15002.6 FL17679-R6 Page 3 of 4 Page 3 of 21 This evaluation report is provided for State of Florida product approval under Rule 61G20-3. The manufacturer shall notify CREEK Technical Services, LLC of any product changes or quality assurance changes throughout the duration for which this report is valid. This evaluation report does not express nor imply warranty, installation, recommended use, or other product attributes that a re not specifically addressed herein. DREXEL METALS, INC. Metal Roofing (HVHZ) DMC 200S Profile: 2 in. mechanical seam; Max. 16 in. coverage Description: Non-structural, mechanical lock standing seam roof panel Material: Min. 0.040 in. Fluropon® coated ASTM B209 aluminum; Fy = min. 20 ksi; Shall conform with FBC Section 1507.4.3 Min. 24 ga. Fluropon® coated ASTM A792 AZ50, or ASTM A653 G90; Fy = min. 50 ksi; Shall conform with FBC Section 1507.4.3 DMC 5V Profile: 3/8 in. ribs; Min. 21 in., Max. 24 in. coverage Description: Non-structural, through fastened roof panel Material: Min. 26 ga. Fluropon® coated ASTM A792 or ASTM A653 G90 ; Fy = min. 50 ksi; Shall conform with FBC Section 1507.4.3 Min. 0.032 in. Fluropon® coated ASTM B209 aluminum; Fy = min. 19 ksi; Shall conform with FBC Section 1507.4.3 LIMITATIONS 1. Fire classification is not within the scope of this evaluation. 2. The roof deck and the roof deck attachment information are provided based on testing. FBC requirements for the rational design of the roof deck, including the attachment, are not within the scope of this evaluation. 3. Roof slope shall be 2:12 or greater. 4. Reroofing shall be in accordance with Section 1521. 5. Installation of the evaluated products shall comply with this report, RAS 133, and the manufacturer’s published application instructions. Where discrepancies exist between these sources, the more restrictive and FBC compliant installation detail shall prevail. 6. All products listed in this report shall be manufactured under a qualit y assurance program in compliance with Rule 61G20-3. A CREEK Technical Services, LLC DRX15002.6 FL17679-R6 Page 4 of 4 Page 4 of 21 This evaluation report is provided for State of Florida product approval under Rule 61G20-3. The manufacturer shall notify CREEK Technical Services, LLC of any product changes or quality assurance changes throughout the duration for which this report is valid. This evaluation report does not express nor imply warranty, installation, recommended use, or other product attributes that are not specifically addressed herein. DREXEL METALS, INC. Metal Roofing (HVHZ) COMPLIANCE STATEMENT The products evaluated herein by Zachary R. Priest, P.E. have demonstrated compliance with the Florida Building Code, 7th Edition (2020) High-Velocity Hurricane Zones (HVHZ) as evidenced in the referenced documents submitted by the named manufacturer. Zachary R. Priest, P.E. Florida Registration No. 74021 Organization No. ANE9641 CERTIFICATION OF INDEPENDENCE CREEK Technical Services, LLC does not have, nor will it acquire, a financial interest in any company manufacturing or distributing products under this evaluation. CREEK Technical Services, LLC is not owned, operated, or controlled by any company manufacturing or distributing products under this evaluation. Zachary R. Priest, P.E. does not have, nor will acquire, a financial interest in any company manufacturing or distributing products under this evaluation. Zachary R. Priest, P.E. does not have, nor will acquire, a financial interest in any other entity involved in the approval process of the product. APPENDICES 1)APPENDIX A – Installation (9 pages) 2)APPENDIX B – Approved Roof Systems (5 pages) 3)APPENDIX C – Design Wind Loads(3 pages) 2020.08.09 15:10:24 -04'00' A CREEK Technical Services, LLC DRX15002.6 FL17679-R6 Page 1 of 9 Page 1 of 21 This evaluation report is provided for State of Florida product approval under Rule 61G20-3. The manufacturer shall notify CREEK Technical Services, LLC of any product changes or quality assurance changes throughout the duration for which this report is valid. This evaluation report does not express nor imply warranty, installation, recommended use, or other product attributes that a re not specifically addressed herein. DREXEL METALS, INC. Metal Roofing (HVHZ) APPENDIX A INSTALLATION Note - Refer to the APPROVED ROOF SYSTEMS section of this report for specific installation details of a selected system. Unless otherwise specified in this report the following installation details shall be met for the named products: Component Product Installation Detail Fasteners #9-15 HWH wood screw with sealing washer Shall penetrate through the sheathing a minimum 3/8 in. Must be corrosion resistant in accordance with FBC section 1507.4.4. #10-13 PH wood screw #10-16 DP3 PH self- drilling screw Shall penetrate through the top rib of the steel deck a minimum 3/4 in. Must be corrosion resistant in accordance with FBC section 1507.4.4. #14-13 DP1 PH self- drilling screw Bearing Plates 18 ga. Bearing Plate Clips 24 ga. DMC 150SS Clip 24 ga. SS in-seam clip 24 ga. DMC 150SS Fixed Clip 24 ga. in-seam clip Clips 22 ga. DMC 150SS Clip 22 ga. SS in-seam clip A CREEK Technical Services, LLC DRX15002.6 FL17679-R6 Page 2 of 9 Page 2 of 21 This evaluation report is provided for State of Florida product approval under Rule 61G20-3. The manufacturer shall notify CREEK Technical Services, LLC of any product changes or quality assurance changes throughout the duration for which this report is valid. This evaluation report does not express nor imply warranty, installation, recommended use, or other product attributes that a re not specifically addressed herein. DREXEL METALS, INC. Metal Roofing (HVHZ) APPENDIX A Component Product Installation Detail 22 ga. DMC 150SS Fixed Clip 22 ga. in-seam clip DMC 150SS Butterfly Clip 22 ga. base; 24 ga. butterfly in-seam clip DMC 150SS Continuous Butterfly Clip 22 ga. base; 24 ga. butterfly in-seam clip Clips DMC 175S UL Clip 18 ga. in-seam clip A CREEK Technical Services, LLC DRX15002.6 FL17679-R6 Page 3 of 9 Page 3 of 21 This evaluation report is provided for State of Florida product approval under Rule 61G20-3. The manufacturer shall notify CREEK Technical Services, LLC of any product changes or quality assurance changes throughout the duration for which this report is valid. This evaluation report does not express nor imply warranty, installation, recommended use, or other product attributes that a re not specifically addressed herein. DREXEL METALS, INC. Metal Roofing (HVHZ) APPENDIX A Component Product Installation Detail lips (Cont’d) DMC 200S Clip 22 ga. SS in-seam clip DMC 200S Butterfly Clip 18 ga. base; 22 ga. butterfly in-seam clip; 4.5 in. length DMC 200S Continuous Butterfly Clip 18 ga. base; 22 ga. butterfly in-seam clip; 120 in. length; top slider 12 in. o.c. Sealants Bostik 70-05A Shall be applied in continuous beads along the seam Bostik Chem-Calk 915 Fastening Details Nomenclature Attachment DMC 100NS Standard A CREEK Technical Services, LLC DRX15002.6 FL17679-R6 Page 4 of 9 Page 4 of 21 This evaluation report is provided for State of Florida product approval under Rule 61G20-3. The manufacturer shall notify CREEK Technical Services, LLC of any product changes or quality assurance changes throughout the duration for which this report is valid. This evaluation report does not express nor imply warranty, installation, recommended use, or other product attributes that a re not specifically addressed herein. DREXEL METALS, INC. Metal Roofing (HVHZ) APPENDIX A Fastening Details Nomenclature Attachment DMC 100NS Enhanced DMC 150SS Continuous Butterfly DMC 150SS Butterfly DMC 150SS Fixed - 90 A CREEK Technical Services, LLC DRX15002.6 FL17679-R6 Page 5 of 9 Page 5 of 21 This evaluation report is provided for State of Florida product approval under Rule 61G20-3. The manufacturer shall notify CREEK Technical Services, LLC of any product changes or quality assurance changes throughout the duration for which this report is valid. This evaluation report does not express nor imply warranty, installation, recommended use, or other product attributes that a re not specifically addressed herein. DREXEL METALS, INC. Metal Roofing (HVHZ) APPENDIX A Fastening Details Nomenclature Attachment DMC 150SS Standard (Al) DMC 150SS Fixed Enhanced - 90 DMC 150SS Fixed Enhanced - 180 A CREEK Technical Services, LLC DRX15002.6 FL17679-R6 Page 6 of 9 Page 6 of 21 This evaluation report is provided for State of Florida product approval under Rule 61G20-3. The manufacturer shall notify CREEK Technical Services, LLC of any product changes or quality assurance changes throughout the duration for which this report is valid. This evaluation report does not express nor imply warranty, installation, recommended use, or other product attributes that a re not specifically addressed herein. DREXEL METALS, INC. Metal Roofing (HVHZ) APPENDIX A Fastening Details Nomenclature Attachment DMC 150SS Enhanced (Al) DMC 175S #10 Standard DMC 175S #14 Standard A CREEK Technical Services, LLC DRX15002.6 FL17679-R6 Page 7 of 9 Page 7 of 21 This evaluation report is provided for State of Florida product approval under Rule 61G20-3. The manufacturer shall notify CREEK Technical Services, LLC of any product changes or quality assurance changes throughout the duration for which this report is valid. This evaluation report does not express nor imply warranty, installation, recommended use, or other product attributes that a re not specifically addressed herein. DREXEL METALS, INC. Metal Roofing (HVHZ) APPENDIX A Fastening Details Nomenclature Attachment DMC 200S Butterfly DMC 200S Butterfly (Steel) Use 18 ga. bearing plate over polyisocyanurate insulation DMC 200S Continuous Butterfly (Steel) Use 18 ga. bearing plate over polyisocyanurate insulation A CREEK Technical Services, LLC DRX15002.6 FL17679-R6 Page 8 of 9 Page 8 of 21 This evaluation report is provided for State of Florida product approval under Rule 61G20-3. The manufacturer shall notify CREEK Technical Services, LLC of any product changes or quality assurance changes throughout the duration for which this report is valid. This evaluation report does not express nor imply warranty, installation, recommended use, or other product attributes that a re not specifically addressed herein. DREXEL METALS, INC. Metal Roofing (HVHZ) APPENDIX A Fastening Details Nomenclature Attachment DMC 200S Fixed DMC 200S Fixed Enhanced DMC 5V Standard A CREEK Technical Services, LLC DRX15002.6 FL17679-R6 Page 9 of 9 Page 9 of 21 This evaluation report is provided for State of Florida product approval under Rule 61G20-3. The manufacturer shall notify CREEK Technical Services, LLC of any product changes or quality assurance changes throughout the duration for which this report is valid. This evaluation report does not express nor imply warranty, installation, recommended use, or other product attributes that a re not specifically addressed herein. DREXEL METALS, INC. Metal Roofing (HVHZ) APPENDIX A Fastening Details Nomenclature Attachment DMC 5V #10 Standard A CREEK Technical Services, LLC DRX15002.6 FL17679-R6 Page 1 of 5 This evaluation report is provided for State of Florida product approval under Rule 61G20-3. The manufacturer shall notify CREEK Technical Services, LLC of any product changes or quality assurance changes throughout the duration for which this report is valid. This evaluation report does not express no r imply warranty, installation, recommended use, or other product attributes that are not specifically addressed herein. DREXEL METALS, INC. Metal Roofing (HVHZ) APPENDIX B APPROVED ROOF SYSTEMS The following notes shall be observed when using the assembly tables below. 1. Maximum Design Pressure (MDP) was calculated using a 2:1 margin of safety per FBC Section 1523.4. 2. Refer to LIMITATIONS and sections of this evaluation when using the table(s) below. 3. Refer to INSTALLATION section of this report for installation detail when the information is not explicitly stated for the selected assembly. 4. The on-center (o.c.) spacing given is the maximum allowable attachment spacing for the rated system. 5. Underlayment shall be installed in accordance with FBC requirements. The minimum underlayment shall be ASTM D 226, Type II installed as described in FBC Section 1518.2.1 with nails and tin caps per 1517.5. 6. Steel Deck shall be designed by others in accordance with FBC requirements and shall be minimum 22 ga (Fy = min.40 ksi) Wide Rib Deck (Type WR) conforming to ANSI/SDI-RD1.0 & FBC. In no case shall the panels be installed on less than two continuous spans, which are spaced a maximum 5 -ft o.c. At minimum, the deck shall be attached with one (1) #12 x 1.5-inch HWH self-drilling screws at the bottom of each flute (maximum. 6-inch o.c. along the support). At minimum, the deck side laps shall be fastened a maximum 6-inch o.c. with #12 x 1.5-inch HWH self-drilling screws. 7. Wood Deck shall be designed by others in accordance with FBC requirements and shall be minimum 19/32-inch thick APA Span-Rated plywood sheathing or wood plank at maximum 24-inch span for new construction. Existing construction shall be the minimum plywood sheathing or wood plank thickness at maximum 24-inch span as stated in the approval tables on following pages . In no case shall the attachment be less than 8d ring shank nails spaced 6-inch o.c. Roof System Numbers and Definitions 100NS-W# DMC 100NS over Wood Deck (New or Existing) 150SS-W# DMC 150SS over Wood Deck (New or Existing) 175S-S# DMC 175S over Steel Deck (New or Existing) 175S-W# DMC 175S over Wood Deck (new or Existing) 200S-S# DMC 200S over Steel Deck (New or Existing) 200S-W# DMC 200S over Wood Deck (New or Existing) 5V-W# DMC 5V over Wood Deck (New or Existing) Approved Systems for DMC 100NS over Wood Deck (New or Existing) System No. Deck Fire Barrier Underlayment Roof Panel Panel Attachment MDP (psf) 100NS-W1 Min. 15/32 CDX plywood OPTIONAL Versashield Solo As required per FBC 24 ga. DMC 100NS Max. 16-inch wide DMC 100NS Standard attachment with fasteners spaced 10.5 in. o.c. -97.5 100NS-W2 Min. 15/32 CDX plywood OPTIONAL Versashield Solo As required per FBC 24 ga. DMC 100NS Max. 16-inch wide DMC 100NS Standard attachment with fasteners spaced 5.25 in. o.c. -120 100NS-W3 Min. 15/32 CDX plywood OPTIONAL Versashield Solo As required per FBC 24 ga. DMC 100NS Max. 16-inch wide DMC 100NS Enhanced attachment with fasteners spaced 5.25 in. o.c. -135 A CREEK Technical Services, LLC DRX15002.6 FL17679-R6 Page 2 of 5 This evaluation report is provided for State of Florida product approval under Rule 61G20-3. The manufacturer shall notify CREEK Technical Services, LLC of any product changes or quality assurance changes throughout the duration for which this report is valid. This evaluation report does not express no r imply warranty, installation, recommended use, or other product attributes that are not specifically addressed herein. DREXEL METALS, INC. Metal Roofing (HVHZ) APPENDIX B Approved Systems for DMC 150SS over Wood Deck (New or Existing) System No. Deck Fire Barrier Underlayment Roof Panel Panel Attachment MDP (psf) 150SS-W1 Min. 15/32 CDX plywood OPTIONAL Versashield Solo As required per FBC 0.032” Al DMC 150SS Max. 16-inch wide 180° seam DMC 150SS Standard (Al) attachment with clips spaced 16 in. o.c. -90 150SS-W2 Min. 15/32 CDX plywood OPTIONAL Versashield Solo As required per FBC 24 ga. DMC 150SS Max. 16-inch wide 90° seam DMC 150SS Fixed - 90 attachment with clips spaced 16 in. o.c. -90 150SS-W3 Min. 15/32 CDX plywood OPTIONAL Versashield Solo As required per FBC 24 ga. DMC 150SS Max. 16-inch wide 180° seam DMC 150SS Butterfly attachment with clips spaced 16 in. o.c. -99.25 150SS-W4 Min. 15/32 CDX plywood OPTIONAL Versashield Solo As required per FBC 24 ga. DMC 150SS Max. 16-inch wide 180° seam DMC 150SS Continuous Butterfly attachment with fasteners spaced 12 in. o.c. -114.25 150SS-W5 Min. 15/32 CDX plywood OPTIONAL Versashield Solo As required per FBC 24 ga. DMC 150SS Max. 16-inch wide Min. 90° seam DMC 150SS Fixed Enhanced - 90 attachment with clips spaced 12 in. o.c. -150 150SS-W6 Min. 15/32 CDX plywood OPTIONAL Versashield Solo As required per FBC 24 ga. DMC 150SS Max. 16-inch wide Min. 180° seam DMC 150SS Fixed Enhanced - 180 attachment with clips spaced 8 in. o.c. -165 150SS-W7 Min. 15/32 CDX plywood OPTIONAL Versashield Solo As required per FBC 0.032” Al DMC 150SS Max. 16-inch wide 180° seam DMC 150SS Enhanced (Al) attachment with clips spaced 8 in. o.c. -180 Approved Systems for DMC 175S over Steel Deck (New or Existing) System No. Deck Fire Barrier Insulation Underlayment Roof Panel Panel Attachment MDP (psf) 175S-S1 Min. 22 ga. Type B Steel As required Min. 1 in. Approved polyisocyanurate insulation board As required per FBC 0.040” Al DMC 175S Max. 17.5-inch wide DMC 175S #14 Standard attachment with clips spaced 18 in. o.c. -88 A CREEK Technical Services, LLC DRX15002.6 FL17679-R6 Page 3 of 5 This evaluation report is provided for State of Florida product approval under Rule 61G20-3. The manufacturer shall notify CREEK Technical Services, LLC of any product changes or quality assurance changes throughout the duration for which this report is valid. This evaluation report does not express no r imply warranty, installation, recommended use, or other product attributes that are not specifically addressed herein. DREXEL METALS, INC. Metal Roofing (HVHZ) APPENDIX B Approved Systems for DMC 175S over Steel Deck (New or Existing) System No. Deck Fire Barrier Insulation Underlayment Roof Panel Panel Attachment MDP (psf) 175S-S2 Min. 22 ga. Type B Steel As required Min. 1 in. Approved polyisocyanurate insulation board As required per FBC 0.040” Al DMC 175S Max. 17.5-inch wide DMC 175S #14 Standard attachment with clips spaced 12 in. o.c. -129.25 Approved Systems for DMC 175S over Wood Deck (New or Existing) System No. Deck Fire Barrier Underlayment Roof Panel Panel Attachment MDP (psf) 175S-W1 Min. 15/32 CDX plywood - ASTM D 226, Type II roofing felt attached per 1518.2.1 with nails and tin caps per 1517.5 followed by Metshield High-Temp Underlayment self-adhered to felt 0.032” Al DMC 175S Max. 18-inch wide DMC 175S #10 Standard attachment with clips spaced 24 in. o.c. -74.75 175S-W2 Min. 15/32 CDX plywood OPTIONAL Versashield Solo As required per FBC 24 ga. DMC 175S Max. 18-inch wide DMC 175S #10 Standard attachment with clips spaced 16 in. o.c. -84.25 175S-W3 Min. 15/32 CDX plywood OPTIONAL Versashield Solo As required per FBC 0.040” Al DMC 175S Max. 17.5-inch wide DMC 175S #10 Standard attachment with clips spaced 18 in. o.c. -106.75 175S-W4 Min. 15/32 CDX plywood OPTIONAL Versashield Solo As required per FBC 24 ga. DMC 175S Max. 18-inch wide DMC 175S #10 Standard attachment with clips spaced 8 in. o.c. -121.75 175S-W5 Min. 15/32 CDX plywood - ASTM D 226, Type II roofing felt attached per 1518.2.1 with nails and tin caps per 1517.5 followed by Metshield High-Temp Underlayment self-adhered to felt 0.032” Al DMC 175S Max. 18-inch wide DMC 175S #10 Standard attachment with clips spaced 6 in. o.c. -131 Approved Systems for DMC 200S over Steel Deck (New or Existing) System No. Deck Fire Barrier Insulation Underlayment Roof Panel Panel Attachment MDP (psf) 200S-S1 Min. 22 ga. Type B Steel As required Min. 1 in. Approved polyisocyanurate insulation board As required per FBC 24 ga. DMC 200S Max. 16-inch wide 180° seam DMC 200S Butterfly (Steel) attachment with clips spaced 24 in. o.c. -88 A CREEK Technical Services, LLC DRX15002.6 FL17679-R6 Page 4 of 5 This evaluation report is provided for State of Florida product approval under Rule 61G20-3. The manufacturer shall notify CREEK Technical Services, LLC of any product changes or quality assurance changes throughout the duration for which this report is valid. This evaluation report does not express no r imply warranty, installation, recommended use, or other product attributes that are not specifically addressed herein. DREXEL METALS, INC. Metal Roofing (HVHZ) APPENDIX B Approved Systems for DMC 200S over Steel Deck (New or Existing) System No. Deck Fire Barrier Insulation Underlayment Roof Panel Panel Attachment MDP (psf) 200S-S2 Min. 22 ga. Type B Steel As required None As required per FBC 24 ga. DMC 200S Max. 16-inch wide 180° seam DMC 200S Butterfly (Steel) attachment with clips spaced 24 in. o.c. -91.75 200S-S3 Min. 22 ga. Type B Steel As required Min. 1 in. Approved polyisocyanurate insulation board As required per FBC 24 ga. DMC 200S Max. 16-inch wide 180° seam DMC 200S Continuous Butterfly (Steel) attachment with clips spaced 12 in. o.c. -121.75 200S-S4 Min. 22 ga. Type B Steel As required None As required per FBC 24 ga. DMC 200S Max. 16-inch wide 180° seam DMC 200S Continuous Butterfly (Steel) attachment with clips spaced 12 in. o.c. -151.75 Approved Systems for DMC 200S over Wood Deck (New or Existing) System No. Deck Fire Barrier Underlayment Roof Panel Panel Attachment MDP (psf) 200S-W1 Min. 19/32 CDX plywood OPTIONAL Versashield Solo As required per FBC 0.040” Al DMC 200S Max. 16-inch wide 180° seam DMC 200S Fixed attachment with clips spaced 16 in. o.c. -105 200S-W2 Min. 19/32 CDX plywood OPTIONAL Versashield Solo As required per FBC 0.040” Al DMC 200S Max. 16-inch wide 180° seam DMC 200S Fixed Enhanced attachment with clips spaced 8 in. o.c. -180 Approved Systems for DMC 5V over Wood Deck (New or Existing) System No. Deck Fire Barrier Underlayment Roof Panel Panel Attachment MDP (psf) 5V-W1 Min. 15/32 CDX plywood OPTIONAL Versashield Solo ASTM D 226, Type II roofing felt attached per 1518.2.1 with nails and tin caps per 1517.5 followed by Metshield High-Temp Underlayment self-adhered to felt 0.032” Al DMC 5V Min. 21-inch to Max. 24-inch coverage DMC 5V #10 Standard attachment with #10-14 HWH wood screws with sealing washers spaced 18 in. o.c. -56 A CREEK Technical Services, LLC DRX15002.6 FL17679-R6 Page 5 of 5 This evaluation report is provided for State of Florida product approval under Rule 61G20-3. The manufacturer shall notify CREEK Technical Services, LLC of any product changes or quality assurance changes throughout the duration for which this report is valid. This evaluation report does not express no r imply warranty, installation, recommended use, or other product attributes that are not specifically addressed herein. DREXEL METALS, INC. Metal Roofing (HVHZ) APPENDIX B Approved Systems for DMC 5V over Wood Deck (New or Existing) System No. Deck Fire Barrier Underlayment Roof Panel Panel Attachment MDP (psf) 5V-W2 Min. 15/32 CDX plywood OPTIONAL Versashield Solo As required per FBC 26 ga, DMC 5V Min. 21-inch to Max. 24-inch coverage DMC 5V Standard attachment with clips spaced 16 in. o.c. -60 5V-W3 Min. 15/32 CDX plywood OPTIONAL Versashield Solo ASTM D 226, Type II roofing felt attached per 1518.2.1 with nails and tin caps per 1517.5 followed by Metshield High-Temp Underlayment self-adhered to felt 26 ga. DMC 5V Min. 21-inch to Max. 24-inch coverage DMC 5V #10 Standard attachment with #10-14 HWH wood screws with sealing washers spaced 24 in. o.c. -71 5V-W4 Min. 15/32 CDX plywood OPTIONAL Versashield Solo As required per FBC 26 ga, DMC 5V Min. 21-inch to Max. 24-inch coverage DMC 5V Standard attachment with clips spaced 8 in. o.c. -121.75 5V-W5 Min. 15/32 CDX plywood OPTIONAL Versashield Solo ASTM D 226, Type II roofing felt attached per 1518.2.1 with nails and tin caps per 1517.5 followed by Metshield High-Temp Underlayment self-adhered to felt 26 ga. DMC 5V or 0.032” Al DMC 5V Min. 21-inch to Max. 24-inch coverage DMC 5V #10 Standard attachment with #10-14 HWH wood screws with sealing washers spaced 6 in. o.c. -206 A CREEK Technical Services, LLC DRX15002.6 FL17679-R6 Page 1 of 3 This evaluation report is provided for State of Florida product approval under Rule 61G20-3. The manufacturer shall notify CREEK Technical Services, LLC of any product changes or quality assurance changes throughout the duration for which this report is valid. This evaluation report does not express no r imply warranty, installation, recommended use, or other product attributes that are not specifically addressed herein. DREXEL METALS, INC. Metal Roofing (HVHZ) APPENDIX C DESIGN WIND LOADS The following tables provide design wind loads for components and cladding in accordance with Section 1620 of the FBC and ASCE 7-16 under the following provisions: 1. Wind speeds for risk category I, II, III, and IV buildings shall be as defined in Section 1620 of the FBC. 2. Exposure C and D shall be as defined in section 1620 of the FBC. 3. Design wind load provided only for gable/hip roofs with roof slopes between 2:12 and 6.1:12 4. All calculations are based on an effective wind area of 10-ft2 or less. 5. Topographic factors such as escarpments or hills have been excluded from the analysis 6. Overhangs have been excluded from the analysis. 7. Wind directionality factor, Kd = 0.85 8. Design wind loads are calculated using Pasd = 0.6Pult. 9. Zone 2 is inclusive of Zone 2e, Zone 2n, and Zone 2r 10. Zone 3 is inclusive of Zone 3e and Zone 3r 11. Projects with mean roof heights greater than 60-ft shall be evaluated by a licensed design professional 12. Zones 1, 2, and 3 shall be defined as shown below. Dimension “a” shall be 10% of the least horizontal dimension or (0.4 x Mean Roof Height), whichever is smaller, but not less than either 4% of the least horizontal dimension or 3ft Gable Hip . a a a 3 3 a 2 2 1 2 3 a 3 2 a 3 2 2 3 3 1 2 2 3 a a a a a 3 3 2 2 1 1 2 2 1 a 2 2 1 3 3 A CREEK Technical Services, LLC DRX15002.6 FL17679-R6 Page 2 of 3 This evaluation report is provided for State of Florida product approval under Rule 61G20-3. The manufacturer shall notify CREEK Technical Services, LLC of any product changes or quality assurance changes throughout the duration for which this report is valid. This evaluation report does not express no r imply warranty, installation, recommended use, or other product attributes that are not specifically addressed herein. DREXEL METALS, INC. Metal Roofing (HVHZ) APPENDIX C Gable/Hip Roofs in Exposure C in Miami-Dade & Broward County (Roof slopes between 2:12 and 12:12) Building Type Zone Mean Roof Height (ft) Basic Wind Speed (mph) Risk Cat I Risk Cat I Risk Cat II Risk Cat II Risk Cat III, IV Risk Cat III,IV 156 165 170 175 180 186 Enclosed/ Partially Open 1 20 -62.3 -69.7 -74.0 -78.5 -83.0 -88.6 25 -65.1 -72.8 -77.3 -81.9 -86.7 -92.6 30 -67.9 -75.9 -80.6 -85.4 -90.4 -96.5 40 -72.0 -80.6 -85.6 -90.7 -95.9 -102.4 50 -75.5 -84.5 -89.7 -95.0 -100.5 -107.3 60 -78.3 -87.6 -93.0 -98.5 -104.2 -111.3 2 20 -90.9 -101.7 -108.0 -114.4 -121.1 -129.3 25 -95.0 -106.3 -112.8 -119.5 -126.5 -135.0 30 -99.0 -110.8 -117.6 -124.6 -131.8 -140.8 40 -105.1 -117.6 -124.8 -132.2 -139.9 -149.4 50 -110.1 -123.2 -130.8 -138.6 -146.6 -156.6 60 -114.2 -127.7 -135.6 -143.7 -152.0 -162.3 3 20 -108.1 -120.9 -128.4 -136.0 -143.9 -153.7 25 -112.9 -126.3 -134.1 -142.1 -150.3 -160.5 30 -117.7 -131.7 -139.8 -148.1 -156.7 -167.3 40 -124.9 -139.7 -148.3 -157.2 -166.3 -177.6 50 -130.9 -146.5 -155.5 -164.7 -174.3 -186.1 60 -135.7 -151.8 -161.2 -170.8 -180.7 -192.9 Partially Enclosed 1 20 -72.9 -81.6 -86.6 -91.8 -97.1 -103.7 25 -76.2 -85.2 -90.4 -95.8 -101.4 -108.3 30 -79.4 -88.8 -94.3 -99.9 -105.7 -112.9 40 -84.3 -94.3 -100.1 -106.0 -112.2 -119.8 50 -88.3 -98.8 -104.9 -111.1 -117.6 -125.5 60 -91.6 -102.4 -108.7 -115.2 -121.9 -130.2 2 20 -101.5 -113.6 -120.6 -127.8 -135.2 -144.3 25 -106.0 -118.6 -125.9 -133.4 -141.2 -150.7 30 -110.5 -123.7 -131.3 -139.1 -147.2 -157.1 40 -117.3 -131.2 -139.3 -147.6 -156.2 -166.8 50 -123.0 -137.5 -146.0 -154.7 -163.7 -174.8 60 -127.5 -142.6 -151.4 -160.4 -169.7 -181.2 3 20 -118.7 -132.8 -140.9 -149.3 -158.0 -168.7 25 -124.0 -138.7 -147.2 -156.0 -165.0 -176.2 30 -129.2 -144.6 -153.5 -162.6 -172.0 -183.7 40 -137.1 -153.4 -162.9 -172.6 -182.6 -195.0 50 -143.7 -160.8 -170.7 -180.9 -191.4 -204.3 60 -149.0 -166.7 -177.0 -187.5 -198.4 -211.8 A CREEK Technical Services, LLC DRX15002.6 FL17679-R6 Page 3 of 3 This evaluation report is provided for State of Florida product approval under Rule 61G20-3. The manufacturer shall notify CREEK Technical Services, LLC of any product changes or quality assurance changes throughout the duration for which this report is valid. This evaluation report does not express no r imply warranty, installation, recommended use, or other product attributes that are not specifically addressed herein. DREXEL METALS, INC. Metal Roofing (HVHZ) APPENDIX C Gable/Hip Roofs in Exposure D in Miami-Dade & Broward County (Roof slopes between 2:12 and 12:12) Building Type Zone Mean Roof Height (ft) Basic Wind Speed (mph) Risk Cat I Risk Cat I Risk Cat II Risk Cat II Risk Cat III, IV Risk Cat III,IV 156 165 170 175 180 186 Enclosed/ Partially Open 1 20 -74.8 -83.7 -88.8 -94.1 -99.6 -106.3 25 -77.6 -86.8 -92.1 -97.6 -103.3 -110.3 30 -80.4 -89.9 -95.4 -101.1 -107.0 -114.2 40 -84.5 -94.5 -100.4 -106.3 -112.5 -120.1 50 -88.0 -98.4 -104.5 -110.7 -117.1 -125.1 60 -90.7 -101.5 -107.8 -114.2 -120.8 -129.0 2 20 -109.1 -122.1 -129.6 -137.3 -145.3 -155.1 25 -113.2 -126.6 -134.4 -142.4 -150.7 -160.9 30 -117.2 -131.1 -139.2 -147.5 -156.0 -166.6 40 -123.3 -137.9 -146.4 -155.1 -164.1 -175.2 50 -128.3 -143.6 -152.4 -161.5 -170.8 -182.4 60 -132.4 -148.1 -157.2 -166.6 -176.2 -188.2 3 20 -129.7 -145.1 -154.0 -163.2 -172.7 -184.4 25 -134.5 -150.5 -159.7 -169.3 -179.1 -191.2 30 -139.3 -155.9 -165.4 -175.3 -185.5 -198.1 40 -146.5 -163.9 -174.0 -184.4 -195.1 -208.3 50 -152.5 -170.6 -181.1 -192.0 -203.1 -216.8 60 -157.3 -176.0 -186.8 -198.0 -209.5 -223.7 Partially Enclosed 1 20 -87.5 -97.9 -103.9 -110.1 -116.5 -124.4 25 -90.7 -101.5 -107.8 -114.2 -120.8 -129.0 30 -94.0 -105.1 -111.6 -118.3 -125.1 -133.6 40 -98.8 -110.6 -117.4 -124.4 -131.6 -140.5 50 -102.9 -115.1 -122.2 -129.5 -137.0 -146.3 60 -106.1 -118.7 -126.0 -133.6 -141.3 -150.9 2 20 -121.8 -136.3 -144.7 -153.3 -162.2 -173.2 25 -126.3 -141.3 -150.0 -159.0 -168.2 -179.6 30 -130.8 -146.4 -155.4 -164.7 -174.2 -186.0 40 -137.6 -154.0 -163.4 -173.2 -183.2 -195.6 50 -143.3 -160.3 -170.1 -180.3 -190.7 -203.6 60 -147.8 -165.3 -175.5 -186.0 -196.7 -210.1 3 20 -142.4 -159.3 -169.1 -179.2 -189.6 -202.5 25 -147.7 -165.2 -175.4 -185.8 -196.6 -210.0 30 -153.0 -171.1 -181.6 -192.5 -203.6 -217.4 40 -160.9 -180.0 -191.0 -202.4 -214.2 -228.7 50 -167.5 -187.3 -198.9 -210.7 -223.0 -238.1 60 -172.7 -193.2 -205.1 -217.4 -230.0 -245.6