Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
APPROVED Design Pressure Report (Manning) - Master Craft Aluminum Products
Property Information Owner:Manning Address:36 Silver Oak Dr Port St Lucie, Fl 34952 Building Information Wind Zone:160 MPH. Exposure Category:B Minimum Building Dimension:24 ft. Mean Roof Height:15 ft. Risk Category:II Design Pressure Calculations Opening Number Location Zone Device Width (in) Device Height (in) Device Elevation (ft) Max Positive Pressure (psf) Max Negative Pressure (psf) 1 Int 52 62 7 30.8 -33.5 2 Int 26 38 7 32.5 -35.2 3 Int 26 38 7 32.5 -35.2 4 Int 74 62 7 30.0 -32.8 5 Int 72 80 7 29.6 -32.3 6 Int 52 62 7 30.8 -33.5 7 Int 52 62 7 30.8 -33.5 Prepared in accordance with: ASCE 7-16, Chapter 30. Wind Loads - Components and Cladding. 7th Edition (2020) Florida Building Code. Page 1 of 1