Loading...
HomeMy WebLinkAboutConstruction Drawingsw 0 N O O O z O O kn N 6 (b (5 (5 m) 0' 25' 50' 75' 100' 0 :U 0, M, 660.03' N 89° 58' 51" W ,. 00 "Alec Ff`YDigitally S ••"�cE"•s�•• � �- ,�N+HAC°j°O signed by No 56787 0�� OVERALL PLAN & SCOPE OF WORK - SCALE: 1:600 .,,P54���NsFy��--'r •as h h k = *: No 56767 * yDate: = STATE OF ftj • STATE OF 0�,' ° -.��• �� P : �,= 202:1.04.1:, `% �' •'�� o Ion'- .. �•• pa,o ��. �'�+ ............. y % 22:03:58 -:_.. ���� &10NAL 0,\xx °j++r1u11N�, r, -04'00' ����� ►11111111�a JASON HANCHU& P.E. DRAWN: JCH JASON HANCHUK, P.E. 10161 RANGE LINE RD., PORT ST. LUCIE, FL 34987 AUG. 14, 2020 1770 PIERSIDE CIR. FLORIDA P.E. NO.: 56787 3.7 M SATELLITE DISH MAST FOUNDATIONS JOB #: 20-169 REV. #: DATE: BY: WELLINGTON, FL 33414 DESIGN: JCH DATE: CONSTRUCTION DRAWINGS SHEET 1 OF 2 �\\\\\\lIII //////// ^ - ®X - AIVCW/1/ No.56787 STATE OF A ///11.111111\\ 3.7 M SERIES 1374 KU-BAND ANTENNAE (TYP.) 1. All design and construction in accordance with the 6th Edition (2017) Florida Building Code. 2. ASCE 7-10, Risk Category III, Ultimate Design Wind Speed: 165 mph (3 second gust), Exposure C. 3. Contractor shall verify all the location of all the underground utilities prior to starting construction. Contractor shall call 811 Sunshine for locates. 4. Contractor shall remove all vegetation, unsatisfactory soils and other deleterious material underneath the proposed foundation. 5. Contractor shall compact the existing subgrade to 98% ASTM D1557 Modified Proctor Maximum Density. 6. Concrete shall have a minimum 28 day compressive strength of 6-5/8" O (O.D.) GALV. 3,000 psi, and water/cement ratio shall not exceed 0.50. STEEL PIPE (TYP.) 7. Minimum concrete cover shall be: Slab: V, Beams and columns: 4"x10'x10' CONCRETE SLAB ON 1-1/2", Tie columns: 3/a", Exposed unprotected concrete: 1-1/2", GRADE W/ #4 @ 12" O.C. EACH WAY Formed concrete below grade: 2", Unformed concrete below grade: 3". 2"x2"x4" x 12" LONG (2 S. Concrete work, including form work and testing shall. be in TOT. - 1 EACH SIDE ' accordance with ACI Standards latest edition. WELDED TO POST NOT • ` :•:; SHOWN (TYP.) 9. Reinforcing bars shall be placed in accordance with CRSI Manual of Standard Practice, latest edition. 24"0 x 72" CONCRETE FOOTING 10. Reinforcing bars shall be ASTM A615 Steel and shall be free of r rust and other debris. 11. Dowels shall be "L" hooked at bottom and shall be lapped 48 "A": TYPICAL MAST ;'` :` Digitally bar diameters with the wall or column reinforcing above. FOUNDATION SECTION signed by •�pN 1 HA/V .,. 12. Contractor shall verify all dimensions prior to construction. 1'1— �� SCALE: —1-0 p``y �,�`�e;.�;cEIV :G�-., Jason ':• Contractor shall report all irregularities or discrepancies to the 4 No 56787 * a hanchuk Engineer prior to proceeding with the work. s�`•. 13. Foundations are designed for a minimum soil bearing value of STATE of 1.`-0��' �� �2021.04.13 S , 2,000 psf. ��',, 22:03:21 -04'00' JASON HANCHUK, P.E. DRAWN: JCH JASON HANCHUK, P.E. 10161 RANGE LINE RD., PORT ST. LUCIE, FL 34987 AUG. 14, 2020 1770 PIERSIDE CIR. FLORIDA P.E. NO.: 56787 3.7 M SATELLITE DISH MAST FOUNDATIONS JOB #: 20-169 REV. #: DATE: BY: WELLINGTON, FL 33414 DESIGN: JCH DATE: CONSTRUCTION DRAWINGS SHEET 2 OF 2 cI W SST. ROOF 660.36' S 890 58' 08" E 4/ 660.03' N 890 58' 51" W OVERALL PLAN & SCOPE OF WORK.- SCALE: 1:600 0' 25' 50' 75' 100' JASON HANCHUK, P.E. DRAWN: JCH JASON HANCHUK, P.E. 10161 RANGE LINE RD., PORT ST. LUCIE, FL 34987 APR. 7, 2020 1770 PIERSIDE CIR. FLORIDA P.E. NO.: 56787 SATELLITE DISH FOUNDATIONS JOB M 20-169 - REV. M DATE: BY: WELLINGTON, FL 33414 DESIGN: JCH DATE: CONSTRUCTION DRAWINGS SHEET 1 OF 4 o. 5678OF zz �• f� GRID rrll►�► 1" 0 x 24" A-325 THREADED ROD W/ 3"x3"x3' WASHER AND NUT (TYP. OF 8) 1" O x 24" A-325 THREADED ROD W/ 3 "x3 "x3" WASHER AND NUT (TYP. OF 18) Y4" _ 15'-6" ANCHOR BOLT PLAN: "A" 6.5 m Andrew ASC M BASE PLATE & ANCHOR BOLTS BY MANUFACTURER REHAB 8 12" EACH WAY (SEE TABLE BELOW) • . IIF��F T �� .31E • LLF 3 ff �; w =Tf =II IfI W � "X" -SEE TABLE FOR DIMENSION (TYP. of "Y") U Q TYPICAL FOUNDATION SECTION 4'-1Y2" o I 1-1/8" 0 x 23" A-325THREADED ROD W/ 3"x3"x3" WASHER AND /11 NUT (TYP. OF 4 BOLTS, TYP. OF 3 PLATES) I ANCHOR BOLT PLAN "B", "Hit, "I", & "J" - 7.3 m Andrew ASC 6-" 0/ F-6 2" 0'-8�6" O O - 0 0'-638"" 0 7/8" fly x 17" A-193 B7 THREADED ROD W/ FLAT WASHER (TYP. OF 8) 12'-0" ANCHOR BOLT PLAN "C" 4.6 m Andrew ASC JASON HANCHUK, P.E. DRAWN: JCH JASON HANCHUK, P.E. 10161 RANGE LINE RD., PORT ST. LUCIE, FL 34987 APR. 7, 2020 1770 PIERSIDE CIR. DESIGN: JCH FLORIDA P.E. NO.: 56787 SATELLITE DISH FOUNDATIONS JOB #: 20-169 REV. M DATE: BY: WELLINGTON, FL 33414 SCALE: 1/4"=P-0" DATE: CONSTRUCTION DRAWINGS SHEET 2 OF 4 MARK # FOOTING SQUARE DIMENSION - "X" FOOTING DEPTH DIMENSION - "Y" FOOTING REINFORCING " A 151-611 2411 #7 "Bit 17'-6" 24" #7 licit 12'-0" 24" #7 "D" 8'-0" 2411 #7 "Eli Not Used "Fit 81-011 24" #7 "G" 22'-0" 24" #7 "Hit 20'-0" 24" #7 "I" 20'-0" 24" #7 "J" 20'-011 24" #7 �� O MARK # LOCATION ANTENNA MODEL SATELLITE FOOTING SQUARE FOOTING DEPTH APPROXIMATE COMMENTS DIMENSION - "X" DIMENSION - "Y" DISH DIAMETER "A" Court Yard 6.5 m Andrew ASC E113W 15'-6" 24" 22'-6" Court Yard 7.3 m Andrew ASC G19 17'-6" 24" 24'-0" "C" Court Yard 4.6 m Andrew ASC El 17 I T-0" 24" 14'-7" ��i Ott '. "D" Court Yard 3.8 in Prodelin Several 8'-0" 24" 14'-0" "E" Not Used ` O. 6787 r "F" North Yard 3.8 m Prodelin SES-15 8'-0" 24" 14'-0" OF ' "G" Front Yard /East 7.0 in Scientific Atlanta Astra 1D 22'-0" 24" 23'-0" ®✓� �' -AI4 OR ID P ------• "H" Front Yard / East 7.3 in Andrew ASC IS34 20'-0" 24" 24'-0" ............: �11z • IV A L lax Front Yard / East 7.3 in Andrew ASC ISl1 20'-0" 24" 24'-0" "J" Front Yard / East 7.3 m Andrew ASC G23 20'-0" 24" 24'-0" 1. All design and construction in accordance with the 6th Edition (2017) Florida Building Code. 2.ASCE 7-10, Risk Category III, Ultimate Design Wind Speed: 165 mph (3 second gust), Exposure C. 3. Contractor shall verify all the location of all the underground utilities prior to starting construction. Contractor shall call 811 Sunshine for locates. unprotected concrete: 1-1/2", Formed concrete below grade: 2", Unformed concrete below grade: 3". 8. Concrete work, including form work and testing shall be in accordance with ACI Standards, latest edition. 9. Reinforcing bars shall be placed in accordance with CRSI Manual of Standard Practice, latest edition. 4. Contractor shall remove all vegetation, unsatisfactory soils and other deleterious material underneath 10. Reinforcing bars shall be ASTM A615 Steel and shall be free of rust and other debris. the proposed foundation. 11. Dowels shall be "L" hooked at bottom and shall be lapped 48 bar diameters with the wall or column 5. Contractor shall compact the existing subgrade to 98% ASTM D 155? Modified Proctor Maximum reinforcing above. Density. 12. Contractor shall verify all dimensions prior to construction. Contractor shall report all irregularities 6. Concrete shall have a minimum 28 day compressive strength of 3,000 psi, and water/cement ratio or discrepancies to the Engineer prior to proceeding with the work. shall not exceed 0.50. 13. Foundations are designed for a minimum soil bearing value of 2,000 psf. 7. Minimum concrete cover shall be: Slab: %", Beams and columns: 1-1/2", Tie columns: V, Exposed JASON HANCHUK, P.E. DRAWN: JCH JASON HANCHUK, P.E. 10161 RANGE LINE RD., PORT ST. LUCIE, FL 34987 APR. 7, 2020 1770 PIERSIDE CIR. FLORIDA P.E. NO.: 56787 SATELLITE DISH FOUNDATIONS JOB #: 20-169 REV. #: DATE: BY: WELLINGTON, FL 33414 DESIGN: JCH DATE: CONSTRUCTION DRAWINGS SHEET 4 OF 4