HomeMy WebLinkAboutAPPROVED Kelly-Polyglass-HVHZ FL Approval.pdf5/19/2021 Florida Building Code Online
Professional Regulation
� 1
BCIS Home Log In User Registration Hot Topics Submit Surcharge Stats & Pacts Publications Contact Us 8CI5 Site Map Links Search
Product Approval
USER: Public User
d b'p r
Product ARgroval Menu > Product or A ti i n Search > AQbllratmn List > Application Detail
FL # FL5259-R32
Application Type Revision
Code Version 2020
Application Status Approved
Comments
Archived
Product Manufacturer POLYGLASS USA
Address/Phone/Email 1111 W. Newport Center Drive
Deerfield Beach, FL 33442
(954) 233-1330 Ext242
malpert@polyglass.com
Authorized Signature Maury Alpert
malpert@polyglass.com
Technical Representative TECH REP
Address/Phone/Email 1111 West Newport Center Drive
Deerfield Beach, FL 33442
(866) 802-8017
uspolyglasstechnical@polyglass.com
Quality Assurance Representative QA REP
Address/Phone/Email 1111 West Newport Center Drive
Deerfield Beach, FL 33442
(888)410-1375
uspolyglasstechnical@polyglass.com
Category Roofing
Subcategory Underlayments
Compliance Method Evaluation Report from a Florida Registered Architect or a Licensed Florida
Professional Engineer
Evaluation Report - Hardcopy Received
Florida Engineer or Architect Name who developed the Robert Nieminen
Evaluation Report
Florida License PE-59166
Quality Assurance Entity UL LLC
Quality Assurance Contract Expiration Date 12/23/2023
Validated By John W. Knezevich, PE
Validation Checklist - Hardcopy Received
Certificate of Independence FI 5259 R32 C01 2020 01 COI NIEMIN N pdf
Referenced Standard and Year (of Standard) Standard Year
ASTM D1970 2015
ASTM D226 2009
ASTM D4798 2011
ASTM D6163 2015
ASTM D6164 2011
ASTM D6222 2011
ASTM D6509 2015
https:llwww.flandabuilding.orglprlpr app_dtl.aspx?param=wGEVXQwtDgvbSgAaZp3Crk2vS%2feg0iiprWbXm5rfv5SiIFMzyU6crw%3d%3d 112
5/19/2021
Florida Building Code Online
FM 4474
2011
FRSA/TRI, Sixth Edition
2018
TAS 103
2020
UL 1897
2015
Equivalence of Product Standards
Certified By
Sections from the Code
Product Approval Method
Method 1 Option D
Date
Submitted
12/21/2020
Date
Validated
1Z/21/2020
Date
Pending FBC Approval
12/26/2020
Date
Approved
02/09/2021
Date
Revised
04/07/2021
Summary of Products
FL #
Model, Number or Name
Description
5259.1
Polyglass Roof Underlayments
Polyglass roof underiayments for use in FBC HVHZ jurisdictions.
(HVHZ)
Limits of Use
Installation Instructions
Approved for use in HVHZ: Yes
FL5259 R32 11 2020 12 21 FINAL ER PLYG UNDERLAYMENTS FL5259-
R32 fHVHZ)_gQ
Approved for use outside HVHZ: No
Impact Resistant: N/A
Verified By: Robert Nieminen PE-59166
Design Pressure: N/A
Created by Independent Third Party: Yes
Other: Refer to ER Section 5 for Limits of Use.
Evaluation Reports
FL5259 R32 AE 2020 12 21 FINAL ER PLYG UNDERLAYMENTS FL5259-
R32 (HVHZ)_gdf
Created by Independent Third Party: Yes
5259.2
Polyglass Roof Underlayments
Polyglass roof underlayments, for use In FBC non-HVHZ jurisdictions.
(non-HVHZ)
Limits of Use
Installation Instructions
Approved for use in HVHZ: No
2 12 21 FINAL ER PLYG UNDERLAYMENTS FL5259-
932 (NON-HVHZ),,ggf
Approved for use outside HVHZ: Yes
Impact Resistant: N/A
Verified By: Robert Merriman PE-59166
Design Pressure: +N/A/-622.5
Created by Independent Third Party: Yes
Other: 1.) The design pressure in this application
Evaluation Reports
relates to one particular underlayment system for
EL5259 R32 AE 2020 12 21 FINAL ER PLYG UNDERLAYMENTS FL5259-
R32 (NON-HVHZ).Qdf
use in the roof systems. Refer to ER Section 5.8.3
for other systems and associated maximum design
Created by Independent Third Party: Yes
pressures. 2.) Refer to ER Section 5 for other limits
of use.
Contact Us :: 2601 Blair Stone Road Tallahassee FL 32399 Phone: 650-487-1824
The State of Ronda is an ANEW employer Copvr aht 2007-2013 state of Florida.:: Privacy Statement :: Accessibility statement :: Refund Statement
Under Florida law, email addresses are public records. If you do not want your e-mail address released in response to a public -records request, do not send electronic
mall to MIs entity. Instead, contact the office by phone or by traditional mall. If you have any questions, please contact 850.487.1395. *pursuant to Section 455.275(1),
Honda Statutes, effective October 1, 2012, licensees licensed under Chapter 455, F.S. must provide the Department with an email address If they have one. The emalls
provided may be used for official communication with the licensee. However email addresses art public record. If you do not wish to supply a personal address, please
provide the Department with an email address which can be made available to the public. To determine if you are a licensee under chapter 455, FS., please dick here .
product Approval Accepts:
®®®F]®
Credit Card
Safe
https:l/www.floddabuilding.orglpr/pr_app_dU.aspx?param--vGEVXOwtDgvbSgAaZp3Crk2vS%2feg011prWbXm5rfv5SiIFMzyU6crv✓%3d%3d 2/2
0
ENGINEER EVALUATE TEST
Polyglass USA, Inc.
1111 West Newport Center Drive
Deerfield Beach, FL 33442
(954)233-1330
NEMO I etc.
Certificate of Authorization #32455
353 Christian Street, Unit#13
Oxford, CT 06478
(203)262-9245
CONSULT
Evaluation Report 3m-PLYG-20-FBCER.A
FL5259-R32(HVHZ)
Date of Issuance:12/21/2020
SCOPE:
This Evaluation Report is issued under Rule 61620-3 and the applicable rules and regulations governing the use of
construction materials in the State of Florida. The documentation submitted has been reviewed by Robert Nieminen, P.E.
for use of the product under the Florida Building Code and Florida Building Code, Residential Volume. The products
described herein have been evaluated for compliance with the 7tb Edition (2020) Florida Building Code sections noted
herein.
DESCRIPTION: Polyglass Roof Underlayments, for use In FBC HVHZ jurisdictions
LABELING: Labeling shall be in accordance with the requirements the Accredited Quality Assurance Agency noted herein
and FBC 1507.1.1.
CONTINUED COMPLIANCE: This Evaluation Report is valid until such time as the named product(s) changes, the referenced Quality
Assurance or production facility location(s) changes, or Code provisions that relate to the product(s) change. Acceptance of
our Evaluation Reports by the named client constitutes agreement to notify NEMO ETC, LLC of any changes to the product(s),
the Quality Assurance or the production facility location(s). NEMO ETC, LLC requires a complete review of its Evaluation Report
relative to updated Code requirements with each Code Cycle.
ADVERTISEMENT: The Florida Product Approval Number (FL#) preceded by the words "NEMOIetc. Evaluated" may be displayed
in advertising literature. If any portion of the Evaluation Report is displayed, then it shall be done in its entirety.
INSPErnON: Upon request, a copy of this entire Evaluation Report shall be provided to the user by the manufacturer or its
distributors and shall be available for inspection at thejob site at the request of the Building Official.
This Evaluation Report consists of pages 1 through 11
Prepared by:
�_
Robert J.M. Nieminen, P.E.
'''' �';'�ep ,l^_i,.��_: The facsimile seal appearing was authorrted by Robert Nieminen, P.E.
Florida Registration No. 59166, Florida DCA ANE1983
on 12/21/2020. This does not serve as an electronically signed
document
CERNFICATION OF INDEPENDENCE:
1. NEMO ETC, LLC does not have, nor does it intend to acquire or will it acquire, a financial interest in any company manufacturing or distributing
products it evaluates.
2. NEMO ETC, LLC is not owned, operated or controlled by any company manufacturing or distributing products it evaluates.
3. Robert Nieminen, P.E. does not have nor will acquire, a financial interest in any company manufacturing or distributing products for which the
evaluation reports are being issued.
4. Robert Nieminen, P.E. does not have, nor will acquire, a financial interest in any other entity involved in the approval process of the product.
S. This is a building code evaluation. Neither NEMO ETC, LLC nor Robert Nieminen, P.E. are, In any way, the Designer of Record for any project on
which this Evaluation Report, or previous versions thereof, is/was used for permitting or design guidance unless retained specifically for that
purpose.
02019 NEMO ETC, LLC
NNEM01letc.
ROOFING COMPONENT EVALUATION:
Product Category: Roofing
Sub -Category: Underlayment
Compliance Statement: Roof Underlayments, as produced by Polyglass USA, Inc., have demonstrated compliance with the
following sections of the 7te Edition (2020) Florida Building Code through testing in accordance with the following Standards.
Compliance is subject to the Installation Requirements and Limitations / Conditions of Use set forth herein.
Section
proper rW
Standard
Year
RAS 115, TAS 110
Material standard
ASTM D226
2009
TAS 110
Material standard
ASTM D1970
2015
TAS 110
Material standard
TAS103
2020
TA5110
Material standard
ASTM D6163
2015
TAS 110
Material standard
ASTM D6164
2011
TAS 110
Material standard
ASTM D6222
2011
TAS 110
Accelerated Weathering
ASTM D4798
2011
3. REFERENCES:
Entltv
Eumination
Reference
Date
fit
Enminanon
Referenle
Dow
ERD (TST 6049)
TAS 1141D
11757.08.01-1
8/13/2001
NEMO UST 6049)
ASTM D1970
4-PLYG-I8-004.03.18
3/29/2028
ERD (TST 6049)
TA5114(C)
P1740.01.07
1/4/2007
NEMO(TST6049)
ASTM D1623, TAS 103
4SI0-18-001.07.11I
7/23/2023
ERD (TST 6049)
ASTM D3623, TAS 103
P31030.11.09-1
11/30/2009
NEMO(TST60491
ASTM D6163
4S-PLYG-I8-002.01.19-A
1/24/2019
ERD UST 6D49)
TAS117I8)/TAS114(C)
P11030.11.09-2
11/30/2009
NEMO(TST 6D49)
ASTM D6222
4SPLYG-I8-002.05.19-C
5/20/2019
Ego(TST 6049)
ASrM D49T7/TAS 103
P73030.31.09-3
11/30/20D9
NEMO(TS76D49)
TA5103
45-PLYG-I8-004.10.19G
10/8/2019
ERD (TST 6049)
ASTM D1970, M798
P37300.10.11
10/19/2011
NEMO PV 60491
TA5103
4SPLYG-18-006.10.19-1
10/8/2019
ERD ITST 6049)
TA5103
P40390.08.12-1
8/6/2012
NEMO (TST 6049)
TAS103
4SPLYG-18-004.10.19-L
10/9/2019
Ego (TST 6049)
ASTM DI623, TAS 103
P40390.08.12-2
8/7/2012
NEMO CM 6049)
TA5103
4SPLYG-18-004.12.19-F
12/18/2019
ERD(TST6049)
ASrM 13I623, TAS 103
C41420.09.12-3
9/11/2012
NEMO IM 6049)
TAS103
4}PLYG-29-SSUDL-02A
1/2/2020
ERD (TST 6049)
ASTM D6509
P37590.03.13-1-RI
2/5/2013
NEMO (TST 6049)
ASTM 01970, 04798
4SPLYG-18-004.01.20.H
1/14/2020
ERD (TST 6049)
TAS 114N1
P39680.03.13
3/4/2013
NEMO (M 6049)
ASTM D3970, M798
4SPLYG-I8-004.01.20.1(
1/14/2020
ERD ITST 6049)
ASTM D6154
P37590.03.13-3A
3/6/2013
NEMO(TST 6049)
TAS 103 (tile slippage)
45-PLYG-18-004.0120.A
1/16/2020
ERD M6049)
ASTM D6164
P37590.07.13-1
7/2/2013
NEMO ITST 6049)
ASTM D6164
4SPLYG-18.004.01.20.B
1/16/2020
ERD CM 6049)
ASTM D4601
P45940.09.13
9/4/2013
NEMO ITST 6049)
TAS103
PLYG-SC35855.05.20.A
5/29/2020
ERD ITST 6D49)
ASTM D1623, TAS 103
P45270.05.14
5/1Z/2014
NEMO RST 5049)
TA5103
41-PLYG-20-SSUDL-01
7/6/2020
ERD UST 6049)
ASTM DI623, TAS 103
6020.09.14-6
9/8/2014
NEMO(M 6049)
ASTM D622-2
4a-PLYG49-SSMBB-0SA
7/23/2020
ERD DW 6049)
TAS103
P44360.10.14-RI
10f7/2014
NEMO OV 6049)
ASTM D4798, DI623
41-P1YG-I9-SSUDL-0S.A
9/10/2020
ERD (TST 6049)
ASTM D3970, M798
P43290.30.14
10/17/2014
NEW (TST 6049)
ASrM D1970
4}PLYG-20-SSUDL-05.A
9/30/2020
ERD ITST 6049)
TA5114(1)
P39680.03.13
3/4/2013
NEMO 0 ST 6049)
TAS103
41-PLYG-20-SSUDL-05.0
9/30/2020
ERD UST 6049)
ASTM 03970,D4798
PLYG-SC30130.06.16-1
6/27/2016
NEMO(TST 6049)
TAS103
4tPLY&M-SSUDL-11.A
10/21/2020
EAD(TST 6049)
ASTM D1623, TA5103
PLYG.SC10130.06.164
6/27/2016
NEMOM76049)
ASTM D1970, D4798
4SPLYG-18-004.1119.0
10/27/2020
ERD ITSF 6049)
TAS103
PLYG-SC30130.06.16.3
6/27/2016
NEMO(TSr 6049)
ASTM 01623. TA5103
4p-ICP-20-SSLAP-01.A
22/15/2020
ERD(M 6049)
TAS 103 (tile slippage)
PLYG-SC13040.12.16
12/27/2026
UL(QUA9625)
Quality Control
Service Confirmation (FL)
09/13/2018
ERD(TST 6049)
TAS 103(tile slippage)
PLYG-SC32115.08.17
8/8/2017
UL(QUA96Z5)
Quality Control
service Confirmadon(TX)
11/07/2019
ERD (TST 6049)
TAS203
PLY13403035.08.17
10/31/2017
UL(QUA9675)
Quality Control
Florida BQS
Current
NEMO ETC, U.C. Evaluation Report 3m-PLYG-20-FBCER.A
Certificate afAuthonaution p3245S 7- EDITION (2020) FBC HVHZ EVALUATION FL5259-R32(HVHZ)
Polyglass Roof Underlayments Revision 28: 12/21/2020
Page 2 of 11
M
4.1
4.2
4.3
4.4
4.5
4.6
4.7
4.8
4.9
4.10
4.11
4.12
4.13
4.14
NNEMOletc.
PRODUCT
Product
Material Standard
Plant(s)
Description
Elastobase
ASTM D6163
FL
Fiberglass -reinforced, SBS modified bitumen base sheet
Elastobase P
ASTM D6164
FL
Polyester -reinforced, SBS modified bitumen base sheet
Elastoflex S6 G
ASTM D6164
FL, PA
Polyester -reinforced, SBS modified bitumen cap sheet
TAS 103 (partial)
Elastoflex S6 G FR
ASTM D6164
FL
Polyester -reinforced, SBS modified bitumen cap sheet
TAS 103 (partial)
Polyflex G
ASTM D6222
FL
Polyester -reinforced, APP modified bitumen cap sheet
TAS 103 (partial)
Polyflex G FR
ASTM D6222
FL
Polyester -reinforced, APP modified bitumen cap sheet
TAS 103 (partial)
Polyflex SA P
ASTM D6222
FL, TX
Polyester -reinforced, APP modified bitumen cap sheet
TAS 103 (partial)
Polyflex SA P FR
ASTM D6222
FL, TX
Polyester -reinforced, APP modified bitumen cap sheet
TAS 103 (partial)
Polystick IR-Xe
ASTM D1970
FL, PA, TX
Nominal 60-mil thick rubberized asphalt waterproofing
membrane, glass fiber reinforced, with an aggregate surface
Polystick MTS Plus
ASTM D1970
FL, NV, PA,
Nominal 60-mil thick rubberized asphalt waterproofing
TAS 103
TX
membrane, glass fiber reinforced, surfaced with poly -film
surface
Polystick TU Max
ASTM D1970
FL, PA, TX
Nominal 60-mil thick rubberized asphalt waterproofing
TAS 103
membrane with a 190 g/m2 polyester fabric surface
Polystick TU P
TAS 103
FL, PA, TX
Nominal 130-mil thick rubberized asphalt waterproofing
membrane, glass-fiber/polyester reinforced, with a granular
surface
Polystick TU Plus
ASTM D1970
FL, PA, TX
Nominal 80-mil thick rubberized asphalt waterproofing
TAS 103
membrane, glass fiber reinforced, with a polyester fabric
surface
Polystick XFR
ASTM D1970
NV, TX
Nominal 80-mil thick rubberized asphalt waterproofing
TAS 103
membrane, glass fiber reinforced, surfaced with a textured
film surface
5.1 This is a Building Code Evaluation. Neither NEW ETC, LLC nor Robert Nieminen, P.E. are, in any way, the Designer of Record
for any project on which this Evaluation Report, or previous versions thereof, is/was used for permitting or design guidance
unless retained specifically forthat purpose.
5.2 This Evaluation Report is not for use in FBC Non -High Velocity Hurricane Zone jurisdictions (i.e., outside of Broward and Miami -
Dade Counties).
5.3 This Evaluation Report pertains to above -deck roof components. Roof decks and structural members shall be in accordance
with FBC requirements to the satisfaction of the Authority Having Jurisdiction.
5.4 This Evaluation Report does not include evaluation of fire classification. Refer to FBC 1516 for requirements and limitations
regarding roof assembly fire classification. Refer to FBC 2603 for requirements and limitations concerning the use of foam
plastic insulation.
NEMO ETC, U.C. Evaluation Report 3m-PLYG-20-F8CER.A
CertifCote ofAuthonration #32455 7^' EDITION (2020) FBC HVHZ EVALUATION FL5259-R32 (HVHZ)
Polyglass Roof Underlayments Revision ZB: 12/21/2020
Page 3 of 11
ONEMO etc.
5.5 Polyglass Roof Underlayments may be used with any prepared roof cover where the product is specifically referenced within
FBC approval documents. If not listed, a request may be made to the Authority Having Jurisdiction for approval based on this
evaluation combined with supporting data for the prepared roof covering.
5.6 Allowable Roof Covers:
TABLE 1: ROOF COVER OPTIONS
FeCSection:
TAS11MWL
TAS 110IS11J,
RAS 133
TAS 1101S11J
us 13o
RAS 115
RAS 118, 119 d 120
Asphalt
day and concrete Tile
Slate or Slate-
Underlayment
Shingles
Metal
Type Shingles
Wood
Mechanical Attach
Adhesive -Set
Yes
Yes
Yes
Yes
Yes
Yes
Elastobase
(Altemateto
(aseasesheet,
(as Base Sheet,
(Alternate to
(Alternate to
(Alternate to
0226,Typell)
See 5.8)
See 5.8)
0226, Type 11)
D226,Type 11)
D226, Type 11)
Yes
Yes
Yes
Yes
Yes
Yes
ElastobaseP
(Alternate to
(as Base Sheet,
(as Base Sheet,
(Alternateto
(Altemateto
(Alternateto
D226, Type III
See 5.8)
See 5.8)
D226, Type II)
D226, Type II)
DZ36, Type II)
Elastoflex S6 G
No
Yes
Yes
No
No
No
(sees 6.1)
Elastoflex S6 G FR
No
Yes
No
No
No
No
Polyflex G
No
Yes
51)
No
No
No
(sees
Polyflex G FR
No
Yes
No
No
No
No
Polyflex SA P
No
Yes
Yes
No
No
No
(see 5.6.1)
Polyflex SA P FR
No
Yes
No
No
No
No
Polystick IR-Xe
Yes
No
No
No
Yes
Yes
Polystick MTS Plus
Yes
Yes
No
Yes
Yes
Yes
Polystick TU Max
No
Yes
Yes
Yes
No
Yes
(see
5.Polystick
TU P
No
Yes
No
No
No
Yes
Polystick TU Plus
Yes
Yes
Yes
Yes
Yes
Yes
(sees.B.1)
Polystick XFR
Yes
Yes
No
Yes
Yes
Yes
5.6.1 Adhesive -set tile is limited to use of the following underlayment / tile -adhesive combinations.
TABLE 1A: ALLOWABLE UNDERLAYMENT / TILE -ADHESIVE COMBINATIONS'
Underlayment
Adhesive
Florida Product
Approval
Polystick TU Max or Polystick TU Plus
DAP Foam "Touch'n Seal
StormBond Roof Tile Adhesive"
NOA 20-0309.05
Polystick TU Max or Polystick TU Plus
Dupont "Tile Bond'" Roof Tile
FL22525
Adhesive"
Elastoflex 56 G, Polyflex G, Polyflex SA P, Polystick TU Max or Polystick TU
ICP Adhesives and Sealants
NOA 17-0322.03
Plus
"Polysete AH-160"
Polystick TU Max or Polystick TU Plus
ICP Adhesives and Sealants
"Polyset RTA-1"
NOA 18-0131.02
'Refer to Tile Manufacturers or Adhesive Manufacturer's Florida ProductApproval for Overtuming Moment Resistance Performance.
NEMO ETC, U.C. Evaluation Report 3m-PLYG-20-FBCER.A
Certlikate afAudlonzation R32455 7r" EDITION(2020) FBC HVHZ EVALUATION FLS259-R3Z(HVHZI
Polyglass Roof Underlayments Revision 28:12/21/2020
Page 4 of 11
5.7
5.8
5.9
5.10
ONEMOjetc.
Allowable Substrates:
TABLE 2: SUBSTRATE OPTIONS FOR ADHERED UNDERLAYMENTS
Underlaymem
Application
Substrates (designed
to meet wind loads for project)
Type
Primer
Material s)
Polystick MAE, Polystick MTS Plus,
Deck
ASTM D41
structural concrete
Base Sheet
N/A
ASTM D226, Type 11 felt, Elastobase, Elastobase P
Polystick TU Max, Polystick TU P,
Polystick TU Plus, Polystick XFR,
self -adhering
Polyflex SA P or Polyflex SA P FR
Elastoflex S6 G or Elastoflex S6 G
FR
hot asphalt
Deck
ASTM D41
structural concrete
I Base Sheet
N/A
ASTM D226, Type II felt, Elastobase, Elastobase P
Polyflex G or Polyflex G FR
torch -applied
Deck
ASTM D41
structural concrete
Base Sheet
N/A
Elastobase, Elastobase P
Attachment Limitations:
Refer to Section 6
Exposure Limitations:
TABLE 3: EXPOSURE LIMITATIONS
Prepared Roof Cover
Maximum
Underlayment
Installation Type
Exposure (days)
Elastobase, Elastobase P, Polyglass G2 Base or Polyglass Base
Mechanically attached
30
Polystick lR-Xe
Mechanically attached
90
Polystick MTS Plus, Polystick TU Max, Polystick TU P, Polystick TU Plus or Polystick
Any type (per Table 1)
180
XFR
Elastoflex S6 G, Polyflex G or Polyflex SA P
Adhesive -set tile roof system
180
Elastoflex S6 G, Elastoflex S6 G FR, Polyflex G, Polyflex G FR, Polyflex SA P or
Mechanically attached
UNLIMITED
Polyflex SA P FR
Tile Slippage Limitations: When loading roof tiles on the underlayment in direct -deck tile roof assemblies, the maximum roof
slope shall be as follows. These slope limitations can only be exceeded by using battens during loading of the roof tiles.
TABLE4: TILE SLIPPAGE LIMITATIONS FOR DIRER-DEcx TILE INSTALLATIONS
Undedayment
Tile Profile
Staging Method
Maximum Staging Slope
Elastoflex 56 G or S6 G FR
Flat or Lugged
6-tile stack (4 over 2)
Prohibited without battens
Polyflex G or G FR
Flat or Lugged
6-tile stack (4 over 2)
4:12
Polyflex SA P or SA P FR
Flat or Lugged
6-tile stack (4 over 2)
4:12
Polystick NITS Plus
Flat
6-tile stack (4 over 2)
5:12
Lugged
6-tile stack (4 over 2)
4:12
Polystick TU Max
Flat
6-tile stack (4 over 2) or 10-tile stack
7:12
Lugged
6-tile stack (4 over 2)
7:12
Lugged
10-tile stack
6:12
Polystick TU P
Flat or Lugged
6-tile stack (4 over 2)
7:12
Polystick TU Plus
Flat or Lugged
6-tile stack (4 over 2)
7:12
Flat or Lugged
10-tile stack
6:12
Polystick XFR
Flat or Lugged
Prohibited without battens
Prohibited without battens
NEMO ETC, U.C. Evaluation Report 3m-PLYG-20.FBCER.A
Certificate ofAuthonmtion r32455 7" EDITION(2020) FBC HVHZ EVALUATION FL5259-1132(HVHZ)
Polyglass Roof Underlayments Revision 28: 1Z/21/2020
Page S of 11
6.1
6.2
6.3
6.3.1
6.3.2
6.3.3
ONEMOIetc.
Polyglass Roof Underlayments shall be installed in accordance with Polyglass published installation instructions subject to
the Limitations set forth in Section 5 herein and the specifics noted below.
Re -fasten any loose decking panels, and check for protruding nail heads. Sweep the substrate thoroughly to remove any dust
and debris prior to application, and prime the substrate (if applicable).
Approved Assemblies:
Deck Type 1: Wood, Non -Insulated
Deck Description:
Min. 19/32" plywood or wood plank
System Type E:
Underlayment mechanically fastened to deck
Underlayment:
One or more plies of Elastobase or Elastobase P with a minimum 4-inch side lap and 6-inch end lap,
mechanically fastened to deck.
Fastening:
FBC HVHZ Approved nails and tin caps (FBC HVHZ 1517.5), 6-inch o.c. at the lap -edges and 12-inch o.c.
in a grid -pattern between the overlaps.
Surfacing:
FBC HVHZ Approved asphalt shingles, metal panels, metal shingles, slate, slate -type shingles, wood
shakes or wood shingles.
Deck Description:
Min. 19/32" plywood or wood plank
System Type E:
Base sheet mechanically fastened to deck; underlayment adhered to base sheet
Base Sheet:
One or more plies of Elastobase, Elastobase P or FBC HVHZ Approved ASTM D226, Type II felt with a
minimum 4-inch side lap and 6-Inch end lap, mechanically fastened to deck.
Fastening:
FBC HVHZ Approved nails and tin caps (FBC HVHZ 1517.5), 6-inch o.c. at the lap -edges and 12-inch o.c.
in a grid -pattern between the overlaps.
Cap Ply:
Elastoflex S6 G applied in hot asphalt or
Polyflex G torch -applied or
Polyflex SA P, self -adhering
and back -nailed max. 12-Inch o.c. using FBC HVHZ Approved nails and tin caps (FBC HVHZ 1517.5).
Surfacing:
FBC HVHZ Approved mechanically attached or adhesive -set tile roof system. Refer to Table 1A for
allowable tile adhesives and Table 4 for tile stagging limitations.
Deck Type 1:
Wood, Non -Insulated
Deck Description:
Min. 19/32" plywood or wood plank
System Type E:
Base sheet mechanically fastened to deck; underlayment adhered to base sheet
Base Sheet:
One or more plies of Elastobase, Elastobase P or FBC HVHZ Approved ASTM D226, Type II felt with a
minimum 4-inch side lap and 6-inch end lap, mechanically fastened to deck.
Fastening:
FBC HVHZ Approved nails and tin caps (FBC HVHZ 1517.5), 6-inch o.c. at the lap -edges and 12-inch o.c.
in a grid -pattern between the overlaps.
Cap Ply:
Elastoflex S6 G FR applied in hot asphalt or
Polyflex G FR torch -applied or
Polyflex SA P FR or Polystick TU P, self -adhering
and back -nailed max. 12-inch o.c. using FBC HVHZ Approved nails and tin caps (FBC HVHZ 1517.5).
Surfacing:
FBC HVHZ Approved mechanically attached tile roof system. Refer to Table 4 for tile stagging
limitations.
NENIO ETC, LLC. Evaluation Report 3m-PLYG-20-FBCER.A
Certificate ofAuthonmtlon 02455 7- EDITION (2020) FBC HVHZ EVALUATION FLS259.R32 (HVHZ)
Polyglass Roof Underlayments Revision 28: 1Z/21/2020
Page 6 of Si
ONEMOjetc.
6.3.4 Deck Type 1: Wood, Non -Insulated
Deck Description: Min.19/32" plywood or wood plank
System Type E: Base sheet mechanically fastened to deck; underlayment adhered to base sheet
Base Sheet: One or more plies of Elastobase, Elastobase P or FBC HVHZ Approved ASTM D226, Type II felt with a
minimum 4-inch side lap and 6-inch end lap, mechanically fastened to deck.
Fastening: FBC HVHZ Approved nails and tin caps (FBC HVHZ 1517.5), 6-inch o.c. at the lap -edges and 12-inch o.c.
in a grid-pattem between the overlaps.
Cap Ply: Polystick IR-Xe self -adhering and back -nailed max.12-inch o.c. using FBC HVHZ Approved nails and tin
caps (FBC HVHZ 1517.5).
Surfacing: FBC HVHZ Approved asphalt shingles, slate, slate -type shingles, wood shakes or wood shingles.
6.3.5 Deck Type 1: Wood, Non -Insulated
Deck Description: Min. 19/32" plywood or wood plank
System Type E: Base sheet mechanically fastened to deck; underlayment adhered to base sheet
Base Sheet: One or more plies of Elastobase, Elastobase P or FBC HVHZ Approved ASTM D226, Type II felt with a
minimum 4-inch side lap and 6-inch end lap, mechanically fastened to deck.
Fastening: FBC HVHZ Approved nails and tin caps (FBC HVHZ 1517.5), 6-inch o.c. at the lap -edges and 12-inch o.c.
in a grid -pattern between the overlaps.
Base Ply: (Optional) Polystick MTS Plus or Polystick XFR, self -adhering and back -nailed max. 12-inch o.c. using
FBC HVHZ Approved nails and tin caps (FBC HVHZ 1517.5)
Cap Ply: Polystick MTS Plus or Polystick XFR, self -adhering and back -nailed max. 12-Inch o.c. using FBC HVHZ
Approved nails and tin caps (FBC HVHZ 1517.5).
Surfacing: FBC HVHZ Approved asphalt shingles, mechanically attached tile roof system, metal panels, metal
shingles, slate, slate -type shingles, wood shakes or wood shingles. Refer to Table 4 for the stagging
limitations.
6.3.6 Deck Type 1: Wood, Non -Insulated
Deck Description: Min.19/32" plywood or wood plank
System Type E: Base sheet mechanically fastened to deck; underlayment adhered to base sheet
Base Sheet: One or more plies of Elastobase, Elastobase P or FBC HVHZ Approved ASTM D226, Type II felt with a
minimum 4-inch side lap and 6-inch end lap, mechanically fastened to deck.
Fastening: FBC HVHZ Approved nails and tin caps (FBC HVHZ 1517.5), 6-inch o.c. at the lap -edges and 12-inch o.c.
in a grid -pattern between the overlaps.
Base Ply: (Optional) Polystick MTS Plus or Polystick XFR, self -adhering and back -nailed max. 12-inch o.c. using
FBC HVHZ Approved nails and tin caps (FBC HVHZ 1517.5)
Cap Ply: Polystick TU Max, self -adhering and back -nailed max.12-inch o.c. using FBC HVHZ Approved nails and
tin caps (FBC HVHZ 1517.5).
Surfacing: FBC HVHZApproved mechanically attached tile roof system, metal panels, metal shingles, wood shakes
or wood shingles. Refer to Table 4 for tile stagging limitations.
NEMO ETC, U.C. Evaluation Report 3m-PLYG-20-FRCER.A
Certificate ofAatlwnzation a32455 7T" EDITION(2020) FBC HVHZ EVALUATION FL5259-R32(HVHZ)
Polyglass Roof Underlayments Revision 28:12/21/2020
Page 7 of 11
6.3.7
6.3.8
6.3.9
NNEMOjetc.
Deck Type 1: Wood, Non -Insulated
Deck Description: Min.19/32" plywood or wood plank
System Type E: Base sheet mechanically fastened to deck; underlayment adhered to base sheet
Base Sheet: One or more plies of Elastobase, Elastobase P or FBC HVHZ Approved ASTM D226, Type II felt with a
minimum 4-inch side lap and 6-inch end lap, mechanically fastened to deck.
Fastening: FBC HVHZ Approved nails and tin caps (FBC HVHZ 1517.5), 6-inch D.E. at the lap -edges and 12-inch o.c.
in a grid -pattern between the overlaps.
Base Ply: (Optional) Polystick MTS Plus or Polystick XFR, self -adhering and back -nailed max. 12-inch o.c. using
FBC HVHZ Approved nails and tin caps (FBC HVHZ 1517.5)
Cap Ply: PolystickTU Plus, self -adhering and back -nailed max. 12-inch o.c. using FBC HVHZ Approved nails and
tin caps (FBC HVHZ 1517.5).
Surfacing: FBC HVHZ Approved asphalt shingles, mechanically attached tile roof system, metal panels, metal
shingles, wood shakes or wood shingles. Refer to Table 4 for tile stagging limitations.
Deck Type 1:
Wood, Non -Insulated
Deck Description:
Min. 19/32" plywood or wood plank
System Type E:
Base sheet mechanically fastened to deck; underlayment adhered to base sheet
Base Sheet:
One or more plies of Elastobase, Elastobase P or FBC HVHZ Approved ASTM D226, Type II felt with a
minimum 4-inch side lap and 6-inch end lap, mechanically fastened to deck.
Fastening:
FBC HVHZ Approved nails and tin caps (FBC HVHZ 1517.5), 6-inch D.E. at the lap -edges and 12-inch o.c.
in a grid -pattern between the overlaps.
Base Ply:
(Optional) Polystick MTS Plus, self -adhering and back -nailed max. 12-inch o.c. using FBC HVHZ
Approved nails and tin caps (FBC HVHZ 1517.5)
Cap Ply:
PolystickTU Max or Polystick TU Plus, self -adhering and back -nailed max. 124nch o.c. using FBC HVHZ
Approved nails and tin caps (FBC HVHZ 1517.5),
Surfacing:
FBC HVHZ Approved adhesive -set tile roof system. Refer to Table 1A for allowable tile adhesives and
Table 4 for tile stagging limitations.
Deck Type 1:
Wood, Non -Insulated
Deck Description:
Min.19/32" plywood or wood plank
System Type E:
Base sheet mechanically fastened to deck; underlayment adhered to base sheet
Base Sheet:
One or more plies of Elastobase or Elastobase P with a minimum 2-inch side lap and 5-inch end lap,
mechanically fastened to deck.
Fastening:
Simplex MAXX Cap Fastener (NOA 18-1227.05), 9-inch o.c. at the lap -edges and 18-inch o.c. in two (2)
equally spaced, staggered center rows.
Cap Ply:
Elastoflex S6 G applied in hot asphalt or
Polyflex G torch -applied
and back -nailed max. 12-inch D.E. using FBC HVHZ Approved nails and tin caps (FBC HVHZ 1517.5).
Surfacing:
FBC HVHZ Approved mechanically attached or adhesive -set tile roof system. Refer to Table SA for
allowable tile adhesives and Table 4 for tile stagging limitations.
NENIO ETC, U.C. Evaluation Report 3m-PLVG-20-FE10ER.A
Certificate ofAvthonzation #32E55 7TH EDITION (2020) FBC HVHZ EVALUATION FL5259.R32 (HVHZ)
Polyglass Roof Underlayments Revision Z8: 12/21/2020
Page 8 of 11
ONEMID I etc.
6.3.10
I Deck Type 1:
Wood, Non -Insulated
Deck Description:
Min.19/32" plywood or wood plank
System Type E:
Base sheet mechanically fastened to deck; underlayment adhered to base sheet
Base Sheet:
One or more plies of Elastobase or Elastobase P with a minimum 3-inch side lap and 6-inch end lap,
mechanically fastened to deck.
Fastening:
Simplex MAXX Cap Fastener (NOA 18-1227.05), 8-inch o.c. at the lap -edges and 8-inch o.c. in three (3)
equally spaced, staggered center rows.
Primer:
PG100 orASTM D41 primer applied to stress plates
Cap Ply:
Polyflex SA P, self -adhering and back -nailed max. 12-inch o.c. using FBC HVHZ Approved nails and tin
caps (FBC HVHZ 1517.5).
Surfacing:
FBC HVHZ Approved mechanically attached or adhesive -set tile roof system. Refer to Table 1A for
allowable tile adhesives and Table 4 for tile stagging limitations.
6.3.11 1 Deck Type 1: Wood, Non -Insulated
Deck Description: Min.19/32" plywood or wood plank
System Type E: Base sheet mechanically fastened to deck; underlayment adhered to base sheet
Base Sheet:
One or more plies of Elastobase or Elastobase P with a minimum 2-inch side lap and 6-inch end lap,
mechanically fastened to deck.
Fastening:
Simplex MAXX Cap Fastener (NOA 18-1227.05), 9-inch o.c. at the lap -edges and 18-inch o.c. In two (2)
equally spaced, staggered center rows.
Cap Ply:
Elastoflex S6 G FR applied in hot asphalt or
Polyflex G FR torch -applied
and back -nailed max. 12-inch o.c. using FBC HVHZ Approved nails and tin caps (FBC HVHZ 1517.5).
Surfacing:
FBC HVHZ Approved mechanically attached tile roof system. Refer to Table 4 for tile stagging
limitations.
6.3.12
I Deck Type 1:
Wood, Non -Insulated
Deck Description:
Min.19/32" plywood or wood plank
System Type E:
Base sheet mechanically fastened to deck; underlayment adhered to base sheet
Base Sheet:
One or more plies of Elastobase or Elastobase P with a minimum 3-inch side lap and 6-inch end lap,
mechanically fastened to deck.
Fastening:
Simplex MAXX Cap Fastener (NOA 18-1227.05), 8-inch o.c. at the lap -edges and 8-inch o.c. in three (3)
equally spaced, staggered center rows.
Primer:
PG100 or ASTM D41 primer applied to stress plates
Cap Ply:
Polyflex SA P FR or PolystickTU P, self -adhering, self -adhering and back -nailed max.12-inch o.c. using
FBC HVHZ Approved nails and tin caps (FBC HVHZ 1517.5).
Surfacing:
FBC HVHZ Approved mechanically attached tile roof system. Refer to Table 4 for tile stagging
limitations.
NENIO ETC, LLC. Evaluation Report 3m-PLVG-20-FBCER.A
Certifrc to ojAutnonzation #32455 7- EDITION (2020) FBC HVHZ EVALUATION FL5259-R32 (HVHZ)
Polyglass Roof Underlayments Revision 28: 12/21/2020
Page 9 of 11
ONEMO I etc.
6.3.13
Deck Type 1:
Wood, Non -Insulated
Deck Description:
Min. 19/32" plywood or wood plank
System Type E:
Base sheet mechanically fastened to deck; underlayment adhered to base sheet
Base Sheet:
One or more plies of Elastobase, Elastobase P felt with a minimum 3-inch side lap and 6-inch end lap,
mechanically fastened to deck.
Fastening:
Simplex MAXX Cap Fastener (NOA 18-1227.05), 8-inch o.c. at the lap -edges and 8-inch o.c. in three (3)
equally spaced, staggered center rows.
Primer:
PG100 or ASTM D41 primer applied to stress plates
Base Ply:
(Optional) Polystick MTS Plus or Polystick XFR, self -adhering and back -nailed max. 12-inch o.c. using
FBC HVHZ Approved nails and tin caps (FBC HVHZ 1517.5)
Cap Ply:
Polystick MTS Pius or Polystick XFR, self -adhering and back -nailed max. 12-inch o.c. using FBC HVHZ
Approved nails and tin caps (FBC HVHZ 1517.5).
Surfacing:
FBC HVHZ Approved asphalt shingles, mechanically attached tile roof system, metal panels, metal
shingles, slate, slate -type shingles, wood shakes or wood shingles. Refer to Table 4 for tile stagging
limitations.
6.3.14 r Deck Type 1: Wood, Non -Insulated
Deck Description: Min. 19/32" plywood or wood plank
System Type E: Base sheet mechanically fastened to deck; underlayment adhered to base sheet
Base Sheet:
One or more plies of Elastobase, Elastobase P or FBC HVHZ Approved ASTM D226, Type II felt with a
minimum 4-inch side lap and 6-inch end lap, mechanically fastened to deck.
Fastening:
Simplex MAXX Cap Fastener (NOA 18-1227.05), 8-inch o.c. at the lap -edges and 8-inch o.c. In three (3)
equally spaced, staggered center rows.
Primer:
PG100 or ASTM D41 primer applied to stress plates
Base Ply:
(Optional) Polystick MTS, Plus or Polystick XFR, self -adhering and back -nailed max. 12-inch o.c. using
FBC HVHZ Approved nails and tin caps (FBC HVHZ 1517.5)
Cap Ply:
Polystick TU Max, self -adhering and back -nailed max.12-inch o.c. using FBC HVHZ Approved nails and
tin caps (FBC HVHZ 1517.5).
Surfacing:
FBC HVHZApproved mechanically attached tile roof system, metal panels, metal shingles, wood shakes
orwoodshingles. Refer to Table 4 for tile stagging limitations.
6.3.15 1 Deck Type 1: Wood, Non -Insulated
Deck Description: Min. 19/32" plywood or wood plank
System Type E: Base sheet mechanically fastened to deck; underlayment adhered to base sheet
Base Sheet: One or more plies of Elastobase, Elastobase P or FBC HVHZ Approved ASTM D226, Type II felt with a
minimum 4-inch side lap and 6-inch end lap, mechanically fastened to deck.
Fastening: Simplex MAXX Cap Fastener (NOA 18-1227.05), 8-inch o.c. at the lap -edges and 8-inch o.c. in three (3)
equally spaced, staggered center rows.
Primer:
Base Ply:
Cap Ply:
Surfacing:
NEMO ETC, LLC.
Certlifkate OfAuthorfmtion p3Z455
PG100 or ASTM D41 primer applied to stress plates
(Optional) Polystick MTS Plus or Polystick XFR, self -adhering and back -nailed max. 12-inch o.c. using
FBC HVHZ Approved nails and tin caps (FBC HVHZ 1517.5)
Polystick TU Plus, self -adhering and back -nailed max.12-inch o.c. using FBC HVHZ Approved nails and
tin caps (FBC HVHZ 1517.5).
FBC HVHZ Approved asphalt shingles, mechanically attached tile roof system, metal panels, metal
shingles, wood shakes or wood shingles. Refer to Table 4 for tile stagging limitations.
7- EDITION (2020) FBC HVHZ EVALUATION
Polyglass Roof Underlayments
Evaluation Report 3m-PLYG-20-FBCER.A
FL5259-R32(HVHZ)
Revision 28: 1Z/21/2020
Page 10 of 11
6.3.16 Deck Type 1: Wood, Non -Insulated OONEMO I etc.
Deck Description: Min. 19/32" plywood or wood plank
System Type E: Base sheet mechanically fastened to deck; underlayment adhered to base sheet
Base Sheet: One or more plies of Elastobase, Elastobase P or FBC HVHZ Approved ASTM D226, Type II felt with a
minimum 4-inch side lap and 6-inch end lap, mechanically fastened to deck.
Fastening: Simplex MAXX Cap Fastener (NOA 18-1227.05), 8-inch o.c. at the lap -edges and 8-inch o.c. in three (3)
equally spaced, staggered center rows.
Primer: PG100 or ASTM D41 primer applied to stress plates
Base Ply: (Optional) Polystick MTS Plus, self -adhering and back -nailed max. 12-inch o.c. using FBC HVHZ
Approved nails and tin caps (FBC HVHZ 1517.5)
Cap Ply: PolystickTU Max or PolystickTU Plus, self -adhering and back -nailed max.12-inch o.c. using FBC HVHZ
Approved nails and tin caps (FBC HVHZ 1517.5).
Surfacing: FBC HVHZ Approved adhesive -set tile roof system. Refer to Table 3A for allowable tile adhesives and
Table 4 for tile stagging limitations.
6.3.17 Deck Type 3: Structural concrete, non -insulated
Deck Description: Min. 2,500 psi structural concrete
System Type F: Underlayment adhered
Primer: ASTM D41
Underlayment: Elastoflex S6 G applied in hot asphalt or
Polyflex G torch -applied or
Polyflex SA P, self -adhering
Surfacing: FBC HVHZ Approved adhesive -set tile roof system. Refer to Table SA for allowable tile adhesives and
Table 4 for tile stagging limitations.
6.3.18 1 Deck Type 3: Structural concrete, non -insulated
Deck Description: Min. 2,500 psi structural concrete
System Type F: Underlayment adhered
Primer: ASTM D41
Base Ply: (Optional) Polystick MTS Plus, self -adhering
Cap Ply: PolystickTU Max or PolystickTU Plus, self -adhering
Surfacing: FBC HVHZ Approved adhesive -set tile roof system. Refer to Table 1A for allowable tile adhesives and
Table 4 for tile stagging limitations.
As required by the Building Official or Authority Having Jurisdiction to properly evaluate the installation of this product.
Contact the named CIA entity for manufacturing facilities covered by F.A.C. Rule 61G20-3 CIA requirements. Refer to
herein for products and production locations having met codified material standards.
UL LLC—QUA9625; (414) 248-6409; Karen.buchmann@ul.com
- END OF EVALUATION REPORT -
NEMO ETC, LLC. Evaluation Report 3m-PLVG-20-FaCER.A
Cerpfixote of Authorization N32455 7- EDITION (2020) FBC HVHZ EVALUATION FL52S9-R32 (HVHZ)
Polyglass Roof Underlayments Revision 28: 12/21/2020
Page 11 of 11