Loading...
HomeMy WebLinkAboutAPPROVED Kelly-Polyglass-HVHZ FL Approval.pdf5/19/2021 Florida Building Code Online Professional Regulation � 1 BCIS Home Log In User Registration Hot Topics Submit Surcharge Stats & Pacts Publications Contact Us 8CI5 Site Map Links Search Product Approval USER: Public User d b'p r Product ARgroval Menu > Product or A ti i n Search > AQbllratmn List > Application Detail FL # FL5259-R32 Application Type Revision Code Version 2020 Application Status Approved Comments Archived Product Manufacturer POLYGLASS USA Address/Phone/Email 1111 W. Newport Center Drive Deerfield Beach, FL 33442 (954) 233-1330 Ext242 malpert@polyglass.com Authorized Signature Maury Alpert malpert@polyglass.com Technical Representative TECH REP Address/Phone/Email 1111 West Newport Center Drive Deerfield Beach, FL 33442 (866) 802-8017 uspolyglasstechnical@polyglass.com Quality Assurance Representative QA REP Address/Phone/Email 1111 West Newport Center Drive Deerfield Beach, FL 33442 (888)410-1375 uspolyglasstechnical@polyglass.com Category Roofing Subcategory Underlayments Compliance Method Evaluation Report from a Florida Registered Architect or a Licensed Florida Professional Engineer Evaluation Report - Hardcopy Received Florida Engineer or Architect Name who developed the Robert Nieminen Evaluation Report Florida License PE-59166 Quality Assurance Entity UL LLC Quality Assurance Contract Expiration Date 12/23/2023 Validated By John W. Knezevich, PE Validation Checklist - Hardcopy Received Certificate of Independence FI 5259 R32 C01 2020 01 COI NIEMIN N pdf Referenced Standard and Year (of Standard) Standard Year ASTM D1970 2015 ASTM D226 2009 ASTM D4798 2011 ASTM D6163 2015 ASTM D6164 2011 ASTM D6222 2011 ASTM D6509 2015 https:llwww.flandabuilding.orglprlpr app_dtl.aspx?param=wGEVXQwtDgvbSgAaZp3Crk2vS%2feg0iiprWbXm5rfv5SiIFMzyU6crw%3d%3d 112 5/19/2021 Florida Building Code Online FM 4474 2011 FRSA/TRI, Sixth Edition 2018 TAS 103 2020 UL 1897 2015 Equivalence of Product Standards Certified By Sections from the Code Product Approval Method Method 1 Option D Date Submitted 12/21/2020 Date Validated 1Z/21/2020 Date Pending FBC Approval 12/26/2020 Date Approved 02/09/2021 Date Revised 04/07/2021 Summary of Products FL # Model, Number or Name Description 5259.1 Polyglass Roof Underlayments Polyglass roof underiayments for use in FBC HVHZ jurisdictions. (HVHZ) Limits of Use Installation Instructions Approved for use in HVHZ: Yes FL5259 R32 11 2020 12 21 FINAL ER PLYG UNDERLAYMENTS FL5259- R32 fHVHZ)_gQ Approved for use outside HVHZ: No Impact Resistant: N/A Verified By: Robert Nieminen PE-59166 Design Pressure: N/A Created by Independent Third Party: Yes Other: Refer to ER Section 5 for Limits of Use. Evaluation Reports FL5259 R32 AE 2020 12 21 FINAL ER PLYG UNDERLAYMENTS FL5259- R32 (HVHZ)_gdf Created by Independent Third Party: Yes 5259.2 Polyglass Roof Underlayments Polyglass roof underlayments, for use In FBC non-HVHZ jurisdictions. (non-HVHZ) Limits of Use Installation Instructions Approved for use in HVHZ: No 2 12 21 FINAL ER PLYG UNDERLAYMENTS FL5259- 932 (NON-HVHZ),,ggf Approved for use outside HVHZ: Yes Impact Resistant: N/A Verified By: Robert Merriman PE-59166 Design Pressure: +N/A/-622.5 Created by Independent Third Party: Yes Other: 1.) The design pressure in this application Evaluation Reports relates to one particular underlayment system for EL5259 R32 AE 2020 12 21 FINAL ER PLYG UNDERLAYMENTS FL5259- R32 (NON-HVHZ).Qdf use in the roof systems. Refer to ER Section 5.8.3 for other systems and associated maximum design Created by Independent Third Party: Yes pressures. 2.) Refer to ER Section 5 for other limits of use. Contact Us :: 2601 Blair Stone Road Tallahassee FL 32399 Phone: 650-487-1824 The State of Ronda is an ANEW employer Copvr aht 2007-2013 state of Florida.:: Privacy Statement :: Accessibility statement :: Refund Statement Under Florida law, email addresses are public records. If you do not want your e-mail address released in response to a public -records request, do not send electronic mall to MIs entity. Instead, contact the office by phone or by traditional mall. If you have any questions, please contact 850.487.1395. *pursuant to Section 455.275(1), Honda Statutes, effective October 1, 2012, licensees licensed under Chapter 455, F.S. must provide the Department with an email address If they have one. The emalls provided may be used for official communication with the licensee. However email addresses art public record. If you do not wish to supply a personal address, please provide the Department with an email address which can be made available to the public. To determine if you are a licensee under chapter 455, FS., please dick here . product Approval Accepts: ®®®F]® Credit Card Safe https:l/www.floddabuilding.orglpr/pr_app_dU.aspx?param--vGEVXOwtDgvbSgAaZp3Crk2vS%2feg011prWbXm5rfv5SiIFMzyU6crv✓%3d%3d 2/2 0 ENGINEER EVALUATE TEST Polyglass USA, Inc. 1111 West Newport Center Drive Deerfield Beach, FL 33442 (954)233-1330 NEMO I etc. Certificate of Authorization #32455 353 Christian Street, Unit#13 Oxford, CT 06478 (203)262-9245 CONSULT Evaluation Report 3m-PLYG-20-FBCER.A FL5259-R32(HVHZ) Date of Issuance:12/21/2020 SCOPE: This Evaluation Report is issued under Rule 61620-3 and the applicable rules and regulations governing the use of construction materials in the State of Florida. The documentation submitted has been reviewed by Robert Nieminen, P.E. for use of the product under the Florida Building Code and Florida Building Code, Residential Volume. The products described herein have been evaluated for compliance with the 7tb Edition (2020) Florida Building Code sections noted herein. DESCRIPTION: Polyglass Roof Underlayments, for use In FBC HVHZ jurisdictions LABELING: Labeling shall be in accordance with the requirements the Accredited Quality Assurance Agency noted herein and FBC 1507.1.1. CONTINUED COMPLIANCE: This Evaluation Report is valid until such time as the named product(s) changes, the referenced Quality Assurance or production facility location(s) changes, or Code provisions that relate to the product(s) change. Acceptance of our Evaluation Reports by the named client constitutes agreement to notify NEMO ETC, LLC of any changes to the product(s), the Quality Assurance or the production facility location(s). NEMO ETC, LLC requires a complete review of its Evaluation Report relative to updated Code requirements with each Code Cycle. ADVERTISEMENT: The Florida Product Approval Number (FL#) preceded by the words "NEMOIetc. Evaluated" may be displayed in advertising literature. If any portion of the Evaluation Report is displayed, then it shall be done in its entirety. INSPErnON: Upon request, a copy of this entire Evaluation Report shall be provided to the user by the manufacturer or its distributors and shall be available for inspection at thejob site at the request of the Building Official. This Evaluation Report consists of pages 1 through 11 Prepared by: �_ Robert J.M. Nieminen, P.E. '''' �';'�ep ,l^_i,.��_: The facsimile seal appearing was authorrted by Robert Nieminen, P.E. Florida Registration No. 59166, Florida DCA ANE1983 on 12/21/2020. This does not serve as an electronically signed document CERNFICATION OF INDEPENDENCE: 1. NEMO ETC, LLC does not have, nor does it intend to acquire or will it acquire, a financial interest in any company manufacturing or distributing products it evaluates. 2. NEMO ETC, LLC is not owned, operated or controlled by any company manufacturing or distributing products it evaluates. 3. Robert Nieminen, P.E. does not have nor will acquire, a financial interest in any company manufacturing or distributing products for which the evaluation reports are being issued. 4. Robert Nieminen, P.E. does not have, nor will acquire, a financial interest in any other entity involved in the approval process of the product. S. This is a building code evaluation. Neither NEMO ETC, LLC nor Robert Nieminen, P.E. are, In any way, the Designer of Record for any project on which this Evaluation Report, or previous versions thereof, is/was used for permitting or design guidance unless retained specifically for that purpose. 02019 NEMO ETC, LLC NNEM01letc. ROOFING COMPONENT EVALUATION: Product Category: Roofing Sub -Category: Underlayment Compliance Statement: Roof Underlayments, as produced by Polyglass USA, Inc., have demonstrated compliance with the following sections of the 7te Edition (2020) Florida Building Code through testing in accordance with the following Standards. Compliance is subject to the Installation Requirements and Limitations / Conditions of Use set forth herein. Section proper rW Standard Year RAS 115, TAS 110 Material standard ASTM D226 2009 TAS 110 Material standard ASTM D1970 2015 TAS 110 Material standard TAS103 2020 TA5110 Material standard ASTM D6163 2015 TAS 110 Material standard ASTM D6164 2011 TAS 110 Material standard ASTM D6222 2011 TAS 110 Accelerated Weathering ASTM D4798 2011 3. REFERENCES: Entltv Eumination Reference Date fit Enminanon Referenle Dow ERD (TST 6049) TAS 1141D 11757.08.01-1 8/13/2001 NEMO UST 6049) ASTM D1970 4-PLYG-I8-004.03.18 3/29/2028 ERD (TST 6049) TA5114(C) P1740.01.07 1/4/2007 NEMO(TST6049) ASTM D1623, TAS 103 4SI0-18-001.07.11I 7/23/2023 ERD (TST 6049) ASTM D3623, TAS 103 P31030.11.09-1 11/30/2009 NEMO(TST60491 ASTM D6163 4S-PLYG-I8-002.01.19-A 1/24/2019 ERD UST 6D49) TAS117I8)/TAS114(C) P11030.11.09-2 11/30/2009 NEMO(TST 6D49) ASTM D6222 4SPLYG-I8-002.05.19-C 5/20/2019 Ego(TST 6049) ASrM D49T7/TAS 103 P73030.31.09-3 11/30/20D9 NEMO(TS76D49) TA5103 45-PLYG-I8-004.10.19G 10/8/2019 ERD (TST 6049) ASTM D1970, M798 P37300.10.11 10/19/2011 NEMO PV 60491 TA5103 4SPLYG-18-006.10.19-1 10/8/2019 ERD ITST 6049) TA5103 P40390.08.12-1 8/6/2012 NEMO (TST 6049) TAS103 4SPLYG-18-004.10.19-L 10/9/2019 Ego (TST 6049) ASTM DI623, TAS 103 P40390.08.12-2 8/7/2012 NEMO CM 6049) TA5103 4SPLYG-18-004.12.19-F 12/18/2019 ERD(TST6049) ASrM 13I623, TAS 103 C41420.09.12-3 9/11/2012 NEMO IM 6049) TAS103 4}PLYG-29-SSUDL-02A 1/2/2020 ERD (TST 6049) ASTM D6509 P37590.03.13-1-RI 2/5/2013 NEMO (TST 6049) ASTM 01970, 04798 4SPLYG-18-004.01.20.H 1/14/2020 ERD (TST 6049) TAS 114N1 P39680.03.13 3/4/2013 NEMO (M 6049) ASTM D3970, M798 4SPLYG-I8-004.01.20.1( 1/14/2020 ERD ITST 6049) ASTM D6154 P37590.03.13-3A 3/6/2013 NEMO(TST 6049) TAS 103 (tile slippage) 45-PLYG-18-004.0120.A 1/16/2020 ERD M6049) ASTM D6164 P37590.07.13-1 7/2/2013 NEMO ITST 6049) ASTM D6164 4SPLYG-18.004.01.20.B 1/16/2020 ERD CM 6049) ASTM D4601 P45940.09.13 9/4/2013 NEMO ITST 6049) TAS103 PLYG-SC35855.05.20.A 5/29/2020 ERD ITST 6D49) ASTM D1623, TAS 103 P45270.05.14 5/1Z/2014 NEMO RST 5049) TA5103 41-PLYG-20-SSUDL-01 7/6/2020 ERD UST 6049) ASTM DI623, TAS 103 6020.09.14-6 9/8/2014 NEMO(M 6049) ASTM D622-2 4a-PLYG49-SSMBB-0SA 7/23/2020 ERD DW 6049) TAS103 P44360.10.14-RI 10f7/2014 NEMO OV 6049) ASTM D4798, DI623 41-P1YG-I9-SSUDL-0S.A 9/10/2020 ERD (TST 6049) ASTM D3970, M798 P43290.30.14 10/17/2014 NEW (TST 6049) ASrM D1970 4}PLYG-20-SSUDL-05.A 9/30/2020 ERD ITST 6049) TA5114(1) P39680.03.13 3/4/2013 NEMO 0 ST 6049) TAS103 41-PLYG-20-SSUDL-05.0 9/30/2020 ERD UST 6049) ASTM 03970,D4798 PLYG-SC30130.06.16-1 6/27/2016 NEMO(TST 6049) TAS103 4tPLY&M-SSUDL-11.A 10/21/2020 EAD(TST 6049) ASTM D1623, TA5103 PLYG.SC10130.06.164 6/27/2016 NEMOM76049) ASTM D1970, D4798 4SPLYG-18-004.1119.0 10/27/2020 ERD ITSF 6049) TAS103 PLYG-SC30130.06.16.3 6/27/2016 NEMO(TSr 6049) ASTM 01623. TA5103 4p-ICP-20-SSLAP-01.A 22/15/2020 ERD(M 6049) TAS 103 (tile slippage) PLYG-SC13040.12.16 12/27/2026 UL(QUA9625) Quality Control Service Confirmation (FL) 09/13/2018 ERD(TST 6049) TAS 103(tile slippage) PLYG-SC32115.08.17 8/8/2017 UL(QUA96Z5) Quality Control service Confirmadon(TX) 11/07/2019 ERD (TST 6049) TAS203 PLY13403035.08.17 10/31/2017 UL(QUA9675) Quality Control Florida BQS Current NEMO ETC, U.C. Evaluation Report 3m-PLYG-20-FBCER.A Certificate afAuthonaution p3245S 7- EDITION (2020) FBC HVHZ EVALUATION FL5259-R32(HVHZ) Polyglass Roof Underlayments Revision 28: 12/21/2020 Page 2 of 11 M 4.1 4.2 4.3 4.4 4.5 4.6 4.7 4.8 4.9 4.10 4.11 4.12 4.13 4.14 NNEMOletc. PRODUCT Product Material Standard Plant(s) Description Elastobase ASTM D6163 FL Fiberglass -reinforced, SBS modified bitumen base sheet Elastobase P ASTM D6164 FL Polyester -reinforced, SBS modified bitumen base sheet Elastoflex S6 G ASTM D6164 FL, PA Polyester -reinforced, SBS modified bitumen cap sheet TAS 103 (partial) Elastoflex S6 G FR ASTM D6164 FL Polyester -reinforced, SBS modified bitumen cap sheet TAS 103 (partial) Polyflex G ASTM D6222 FL Polyester -reinforced, APP modified bitumen cap sheet TAS 103 (partial) Polyflex G FR ASTM D6222 FL Polyester -reinforced, APP modified bitumen cap sheet TAS 103 (partial) Polyflex SA P ASTM D6222 FL, TX Polyester -reinforced, APP modified bitumen cap sheet TAS 103 (partial) Polyflex SA P FR ASTM D6222 FL, TX Polyester -reinforced, APP modified bitumen cap sheet TAS 103 (partial) Polystick IR-Xe ASTM D1970 FL, PA, TX Nominal 60-mil thick rubberized asphalt waterproofing membrane, glass fiber reinforced, with an aggregate surface Polystick MTS Plus ASTM D1970 FL, NV, PA, Nominal 60-mil thick rubberized asphalt waterproofing TAS 103 TX membrane, glass fiber reinforced, surfaced with poly -film surface Polystick TU Max ASTM D1970 FL, PA, TX Nominal 60-mil thick rubberized asphalt waterproofing TAS 103 membrane with a 190 g/m2 polyester fabric surface Polystick TU P TAS 103 FL, PA, TX Nominal 130-mil thick rubberized asphalt waterproofing membrane, glass-fiber/polyester reinforced, with a granular surface Polystick TU Plus ASTM D1970 FL, PA, TX Nominal 80-mil thick rubberized asphalt waterproofing TAS 103 membrane, glass fiber reinforced, with a polyester fabric surface Polystick XFR ASTM D1970 NV, TX Nominal 80-mil thick rubberized asphalt waterproofing TAS 103 membrane, glass fiber reinforced, surfaced with a textured film surface 5.1 This is a Building Code Evaluation. Neither NEW ETC, LLC nor Robert Nieminen, P.E. are, in any way, the Designer of Record for any project on which this Evaluation Report, or previous versions thereof, is/was used for permitting or design guidance unless retained specifically forthat purpose. 5.2 This Evaluation Report is not for use in FBC Non -High Velocity Hurricane Zone jurisdictions (i.e., outside of Broward and Miami - Dade Counties). 5.3 This Evaluation Report pertains to above -deck roof components. Roof decks and structural members shall be in accordance with FBC requirements to the satisfaction of the Authority Having Jurisdiction. 5.4 This Evaluation Report does not include evaluation of fire classification. Refer to FBC 1516 for requirements and limitations regarding roof assembly fire classification. Refer to FBC 2603 for requirements and limitations concerning the use of foam plastic insulation. NEMO ETC, U.C. Evaluation Report 3m-PLYG-20-F8CER.A CertifCote ofAuthonration #32455 7^' EDITION (2020) FBC HVHZ EVALUATION FL5259-R32 (HVHZ) Polyglass Roof Underlayments Revision ZB: 12/21/2020 Page 3 of 11 ONEMO etc. 5.5 Polyglass Roof Underlayments may be used with any prepared roof cover where the product is specifically referenced within FBC approval documents. If not listed, a request may be made to the Authority Having Jurisdiction for approval based on this evaluation combined with supporting data for the prepared roof covering. 5.6 Allowable Roof Covers: TABLE 1: ROOF COVER OPTIONS FeCSection: TAS11MWL TAS 110IS11J, RAS 133 TAS 1101S11J us 13o RAS 115 RAS 118, 119 d 120 Asphalt day and concrete Tile Slate or Slate- Underlayment Shingles Metal Type Shingles Wood Mechanical Attach Adhesive -Set Yes Yes Yes Yes Yes Yes Elastobase (Altemateto (aseasesheet, (as Base Sheet, (Alternate to (Alternate to (Alternate to 0226,Typell) See 5.8) See 5.8) 0226, Type 11) D226,Type 11) D226, Type 11) Yes Yes Yes Yes Yes Yes ElastobaseP (Alternate to (as Base Sheet, (as Base Sheet, (Alternateto (Altemateto (Alternateto D226, Type III See 5.8) See 5.8) D226, Type II) D226, Type II) DZ36, Type II) Elastoflex S6 G No Yes Yes No No No (sees 6.1) Elastoflex S6 G FR No Yes No No No No Polyflex G No Yes 51) No No No (sees Polyflex G FR No Yes No No No No Polyflex SA P No Yes Yes No No No (see 5.6.1) Polyflex SA P FR No Yes No No No No Polystick IR-Xe Yes No No No Yes Yes Polystick MTS Plus Yes Yes No Yes Yes Yes Polystick TU Max No Yes Yes Yes No Yes (see 5.Polystick TU P No Yes No No No Yes Polystick TU Plus Yes Yes Yes Yes Yes Yes (sees.B.1) Polystick XFR Yes Yes No Yes Yes Yes 5.6.1 Adhesive -set tile is limited to use of the following underlayment / tile -adhesive combinations. TABLE 1A: ALLOWABLE UNDERLAYMENT / TILE -ADHESIVE COMBINATIONS' Underlayment Adhesive Florida Product Approval Polystick TU Max or Polystick TU Plus DAP Foam "Touch'n Seal StormBond Roof Tile Adhesive" NOA 20-0309.05 Polystick TU Max or Polystick TU Plus Dupont "Tile Bond'" Roof Tile FL22525 Adhesive" Elastoflex 56 G, Polyflex G, Polyflex SA P, Polystick TU Max or Polystick TU ICP Adhesives and Sealants NOA 17-0322.03 Plus "Polysete AH-160" Polystick TU Max or Polystick TU Plus ICP Adhesives and Sealants "Polyset RTA-1" NOA 18-0131.02 'Refer to Tile Manufacturers or Adhesive Manufacturer's Florida ProductApproval for Overtuming Moment Resistance Performance. NEMO ETC, U.C. Evaluation Report 3m-PLYG-20-FBCER.A Certlikate afAudlonzation R32455 7r" EDITION(2020) FBC HVHZ EVALUATION FLS259-R3Z(HVHZI Polyglass Roof Underlayments Revision 28:12/21/2020 Page 4 of 11 5.7 5.8 5.9 5.10 ONEMOjetc. Allowable Substrates: TABLE 2: SUBSTRATE OPTIONS FOR ADHERED UNDERLAYMENTS Underlaymem Application Substrates (designed to meet wind loads for project) Type Primer Material s) Polystick MAE, Polystick MTS Plus, Deck ASTM D41 structural concrete Base Sheet N/A ASTM D226, Type 11 felt, Elastobase, Elastobase P Polystick TU Max, Polystick TU P, Polystick TU Plus, Polystick XFR, self -adhering Polyflex SA P or Polyflex SA P FR Elastoflex S6 G or Elastoflex S6 G FR hot asphalt Deck ASTM D41 structural concrete I Base Sheet N/A ASTM D226, Type II felt, Elastobase, Elastobase P Polyflex G or Polyflex G FR torch -applied Deck ASTM D41 structural concrete Base Sheet N/A Elastobase, Elastobase P Attachment Limitations: Refer to Section 6 Exposure Limitations: TABLE 3: EXPOSURE LIMITATIONS Prepared Roof Cover Maximum Underlayment Installation Type Exposure (days) Elastobase, Elastobase P, Polyglass G2 Base or Polyglass Base Mechanically attached 30 Polystick lR-Xe Mechanically attached 90 Polystick MTS Plus, Polystick TU Max, Polystick TU P, Polystick TU Plus or Polystick Any type (per Table 1) 180 XFR Elastoflex S6 G, Polyflex G or Polyflex SA P Adhesive -set tile roof system 180 Elastoflex S6 G, Elastoflex S6 G FR, Polyflex G, Polyflex G FR, Polyflex SA P or Mechanically attached UNLIMITED Polyflex SA P FR Tile Slippage Limitations: When loading roof tiles on the underlayment in direct -deck tile roof assemblies, the maximum roof slope shall be as follows. These slope limitations can only be exceeded by using battens during loading of the roof tiles. TABLE4: TILE SLIPPAGE LIMITATIONS FOR DIRER-DEcx TILE INSTALLATIONS Undedayment Tile Profile Staging Method Maximum Staging Slope Elastoflex 56 G or S6 G FR Flat or Lugged 6-tile stack (4 over 2) Prohibited without battens Polyflex G or G FR Flat or Lugged 6-tile stack (4 over 2) 4:12 Polyflex SA P or SA P FR Flat or Lugged 6-tile stack (4 over 2) 4:12 Polystick NITS Plus Flat 6-tile stack (4 over 2) 5:12 Lugged 6-tile stack (4 over 2) 4:12 Polystick TU Max Flat 6-tile stack (4 over 2) or 10-tile stack 7:12 Lugged 6-tile stack (4 over 2) 7:12 Lugged 10-tile stack 6:12 Polystick TU P Flat or Lugged 6-tile stack (4 over 2) 7:12 Polystick TU Plus Flat or Lugged 6-tile stack (4 over 2) 7:12 Flat or Lugged 10-tile stack 6:12 Polystick XFR Flat or Lugged Prohibited without battens Prohibited without battens NEMO ETC, U.C. Evaluation Report 3m-PLYG-20.FBCER.A Certificate ofAuthonmtion r32455 7" EDITION(2020) FBC HVHZ EVALUATION FL5259-1132(HVHZ) Polyglass Roof Underlayments Revision 28: 1Z/21/2020 Page S of 11 6.1 6.2 6.3 6.3.1 6.3.2 6.3.3 ONEMOIetc. Polyglass Roof Underlayments shall be installed in accordance with Polyglass published installation instructions subject to the Limitations set forth in Section 5 herein and the specifics noted below. Re -fasten any loose decking panels, and check for protruding nail heads. Sweep the substrate thoroughly to remove any dust and debris prior to application, and prime the substrate (if applicable). Approved Assemblies: Deck Type 1: Wood, Non -Insulated Deck Description: Min. 19/32" plywood or wood plank System Type E: Underlayment mechanically fastened to deck Underlayment: One or more plies of Elastobase or Elastobase P with a minimum 4-inch side lap and 6-inch end lap, mechanically fastened to deck. Fastening: FBC HVHZ Approved nails and tin caps (FBC HVHZ 1517.5), 6-inch o.c. at the lap -edges and 12-inch o.c. in a grid -pattern between the overlaps. Surfacing: FBC HVHZ Approved asphalt shingles, metal panels, metal shingles, slate, slate -type shingles, wood shakes or wood shingles. Deck Description: Min. 19/32" plywood or wood plank System Type E: Base sheet mechanically fastened to deck; underlayment adhered to base sheet Base Sheet: One or more plies of Elastobase, Elastobase P or FBC HVHZ Approved ASTM D226, Type II felt with a minimum 4-inch side lap and 6-Inch end lap, mechanically fastened to deck. Fastening: FBC HVHZ Approved nails and tin caps (FBC HVHZ 1517.5), 6-inch o.c. at the lap -edges and 12-inch o.c. in a grid -pattern between the overlaps. Cap Ply: Elastoflex S6 G applied in hot asphalt or Polyflex G torch -applied or Polyflex SA P, self -adhering and back -nailed max. 12-Inch o.c. using FBC HVHZ Approved nails and tin caps (FBC HVHZ 1517.5). Surfacing: FBC HVHZ Approved mechanically attached or adhesive -set tile roof system. Refer to Table 1A for allowable tile adhesives and Table 4 for tile stagging limitations. Deck Type 1: Wood, Non -Insulated Deck Description: Min. 19/32" plywood or wood plank System Type E: Base sheet mechanically fastened to deck; underlayment adhered to base sheet Base Sheet: One or more plies of Elastobase, Elastobase P or FBC HVHZ Approved ASTM D226, Type II felt with a minimum 4-inch side lap and 6-inch end lap, mechanically fastened to deck. Fastening: FBC HVHZ Approved nails and tin caps (FBC HVHZ 1517.5), 6-inch o.c. at the lap -edges and 12-inch o.c. in a grid -pattern between the overlaps. Cap Ply: Elastoflex S6 G FR applied in hot asphalt or Polyflex G FR torch -applied or Polyflex SA P FR or Polystick TU P, self -adhering and back -nailed max. 12-inch o.c. using FBC HVHZ Approved nails and tin caps (FBC HVHZ 1517.5). Surfacing: FBC HVHZ Approved mechanically attached tile roof system. Refer to Table 4 for tile stagging limitations. NENIO ETC, LLC. Evaluation Report 3m-PLYG-20-FBCER.A Certificate ofAuthonmtlon 02455 7- EDITION (2020) FBC HVHZ EVALUATION FLS259.R32 (HVHZ) Polyglass Roof Underlayments Revision 28: 1Z/21/2020 Page 6 of Si ONEMOjetc. 6.3.4 Deck Type 1: Wood, Non -Insulated Deck Description: Min.19/32" plywood or wood plank System Type E: Base sheet mechanically fastened to deck; underlayment adhered to base sheet Base Sheet: One or more plies of Elastobase, Elastobase P or FBC HVHZ Approved ASTM D226, Type II felt with a minimum 4-inch side lap and 6-inch end lap, mechanically fastened to deck. Fastening: FBC HVHZ Approved nails and tin caps (FBC HVHZ 1517.5), 6-inch o.c. at the lap -edges and 12-inch o.c. in a grid-pattem between the overlaps. Cap Ply: Polystick IR-Xe self -adhering and back -nailed max.12-inch o.c. using FBC HVHZ Approved nails and tin caps (FBC HVHZ 1517.5). Surfacing: FBC HVHZ Approved asphalt shingles, slate, slate -type shingles, wood shakes or wood shingles. 6.3.5 Deck Type 1: Wood, Non -Insulated Deck Description: Min. 19/32" plywood or wood plank System Type E: Base sheet mechanically fastened to deck; underlayment adhered to base sheet Base Sheet: One or more plies of Elastobase, Elastobase P or FBC HVHZ Approved ASTM D226, Type II felt with a minimum 4-inch side lap and 6-inch end lap, mechanically fastened to deck. Fastening: FBC HVHZ Approved nails and tin caps (FBC HVHZ 1517.5), 6-inch o.c. at the lap -edges and 12-inch o.c. in a grid -pattern between the overlaps. Base Ply: (Optional) Polystick MTS Plus or Polystick XFR, self -adhering and back -nailed max. 12-inch o.c. using FBC HVHZ Approved nails and tin caps (FBC HVHZ 1517.5) Cap Ply: Polystick MTS Plus or Polystick XFR, self -adhering and back -nailed max. 12-Inch o.c. using FBC HVHZ Approved nails and tin caps (FBC HVHZ 1517.5). Surfacing: FBC HVHZ Approved asphalt shingles, mechanically attached tile roof system, metal panels, metal shingles, slate, slate -type shingles, wood shakes or wood shingles. Refer to Table 4 for the stagging limitations. 6.3.6 Deck Type 1: Wood, Non -Insulated Deck Description: Min.19/32" plywood or wood plank System Type E: Base sheet mechanically fastened to deck; underlayment adhered to base sheet Base Sheet: One or more plies of Elastobase, Elastobase P or FBC HVHZ Approved ASTM D226, Type II felt with a minimum 4-inch side lap and 6-inch end lap, mechanically fastened to deck. Fastening: FBC HVHZ Approved nails and tin caps (FBC HVHZ 1517.5), 6-inch o.c. at the lap -edges and 12-inch o.c. in a grid -pattern between the overlaps. Base Ply: (Optional) Polystick MTS Plus or Polystick XFR, self -adhering and back -nailed max. 12-inch o.c. using FBC HVHZ Approved nails and tin caps (FBC HVHZ 1517.5) Cap Ply: Polystick TU Max, self -adhering and back -nailed max.12-inch o.c. using FBC HVHZ Approved nails and tin caps (FBC HVHZ 1517.5). Surfacing: FBC HVHZApproved mechanically attached tile roof system, metal panels, metal shingles, wood shakes or wood shingles. Refer to Table 4 for tile stagging limitations. NEMO ETC, U.C. Evaluation Report 3m-PLYG-20-FRCER.A Certificate ofAatlwnzation a32455 7T" EDITION(2020) FBC HVHZ EVALUATION FL5259-R32(HVHZ) Polyglass Roof Underlayments Revision 28:12/21/2020 Page 7 of 11 6.3.7 6.3.8 6.3.9 NNEMOjetc. Deck Type 1: Wood, Non -Insulated Deck Description: Min.19/32" plywood or wood plank System Type E: Base sheet mechanically fastened to deck; underlayment adhered to base sheet Base Sheet: One or more plies of Elastobase, Elastobase P or FBC HVHZ Approved ASTM D226, Type II felt with a minimum 4-inch side lap and 6-inch end lap, mechanically fastened to deck. Fastening: FBC HVHZ Approved nails and tin caps (FBC HVHZ 1517.5), 6-inch D.E. at the lap -edges and 12-inch o.c. in a grid -pattern between the overlaps. Base Ply: (Optional) Polystick MTS Plus or Polystick XFR, self -adhering and back -nailed max. 12-inch o.c. using FBC HVHZ Approved nails and tin caps (FBC HVHZ 1517.5) Cap Ply: PolystickTU Plus, self -adhering and back -nailed max. 12-inch o.c. using FBC HVHZ Approved nails and tin caps (FBC HVHZ 1517.5). Surfacing: FBC HVHZ Approved asphalt shingles, mechanically attached tile roof system, metal panels, metal shingles, wood shakes or wood shingles. Refer to Table 4 for tile stagging limitations. Deck Type 1: Wood, Non -Insulated Deck Description: Min. 19/32" plywood or wood plank System Type E: Base sheet mechanically fastened to deck; underlayment adhered to base sheet Base Sheet: One or more plies of Elastobase, Elastobase P or FBC HVHZ Approved ASTM D226, Type II felt with a minimum 4-inch side lap and 6-inch end lap, mechanically fastened to deck. Fastening: FBC HVHZ Approved nails and tin caps (FBC HVHZ 1517.5), 6-inch D.E. at the lap -edges and 12-inch o.c. in a grid -pattern between the overlaps. Base Ply: (Optional) Polystick MTS Plus, self -adhering and back -nailed max. 12-inch o.c. using FBC HVHZ Approved nails and tin caps (FBC HVHZ 1517.5) Cap Ply: PolystickTU Max or Polystick TU Plus, self -adhering and back -nailed max. 124nch o.c. using FBC HVHZ Approved nails and tin caps (FBC HVHZ 1517.5), Surfacing: FBC HVHZ Approved adhesive -set tile roof system. Refer to Table 1A for allowable tile adhesives and Table 4 for tile stagging limitations. Deck Type 1: Wood, Non -Insulated Deck Description: Min.19/32" plywood or wood plank System Type E: Base sheet mechanically fastened to deck; underlayment adhered to base sheet Base Sheet: One or more plies of Elastobase or Elastobase P with a minimum 2-inch side lap and 5-inch end lap, mechanically fastened to deck. Fastening: Simplex MAXX Cap Fastener (NOA 18-1227.05), 9-inch o.c. at the lap -edges and 18-inch o.c. in two (2) equally spaced, staggered center rows. Cap Ply: Elastoflex S6 G applied in hot asphalt or Polyflex G torch -applied and back -nailed max. 12-inch D.E. using FBC HVHZ Approved nails and tin caps (FBC HVHZ 1517.5). Surfacing: FBC HVHZ Approved mechanically attached or adhesive -set tile roof system. Refer to Table SA for allowable tile adhesives and Table 4 for tile stagging limitations. NENIO ETC, U.C. Evaluation Report 3m-PLVG-20-FE10ER.A Certificate ofAvthonzation #32E55 7TH EDITION (2020) FBC HVHZ EVALUATION FL5259.R32 (HVHZ) Polyglass Roof Underlayments Revision Z8: 12/21/2020 Page 8 of 11 ONEMID I etc. 6.3.10 I Deck Type 1: Wood, Non -Insulated Deck Description: Min.19/32" plywood or wood plank System Type E: Base sheet mechanically fastened to deck; underlayment adhered to base sheet Base Sheet: One or more plies of Elastobase or Elastobase P with a minimum 3-inch side lap and 6-inch end lap, mechanically fastened to deck. Fastening: Simplex MAXX Cap Fastener (NOA 18-1227.05), 8-inch o.c. at the lap -edges and 8-inch o.c. in three (3) equally spaced, staggered center rows. Primer: PG100 orASTM D41 primer applied to stress plates Cap Ply: Polyflex SA P, self -adhering and back -nailed max. 12-inch o.c. using FBC HVHZ Approved nails and tin caps (FBC HVHZ 1517.5). Surfacing: FBC HVHZ Approved mechanically attached or adhesive -set tile roof system. Refer to Table 1A for allowable tile adhesives and Table 4 for tile stagging limitations. 6.3.11 1 Deck Type 1: Wood, Non -Insulated Deck Description: Min.19/32" plywood or wood plank System Type E: Base sheet mechanically fastened to deck; underlayment adhered to base sheet Base Sheet: One or more plies of Elastobase or Elastobase P with a minimum 2-inch side lap and 6-inch end lap, mechanically fastened to deck. Fastening: Simplex MAXX Cap Fastener (NOA 18-1227.05), 9-inch o.c. at the lap -edges and 18-inch o.c. In two (2) equally spaced, staggered center rows. Cap Ply: Elastoflex S6 G FR applied in hot asphalt or Polyflex G FR torch -applied and back -nailed max. 12-inch o.c. using FBC HVHZ Approved nails and tin caps (FBC HVHZ 1517.5). Surfacing: FBC HVHZ Approved mechanically attached tile roof system. Refer to Table 4 for tile stagging limitations. 6.3.12 I Deck Type 1: Wood, Non -Insulated Deck Description: Min.19/32" plywood or wood plank System Type E: Base sheet mechanically fastened to deck; underlayment adhered to base sheet Base Sheet: One or more plies of Elastobase or Elastobase P with a minimum 3-inch side lap and 6-inch end lap, mechanically fastened to deck. Fastening: Simplex MAXX Cap Fastener (NOA 18-1227.05), 8-inch o.c. at the lap -edges and 8-inch o.c. in three (3) equally spaced, staggered center rows. Primer: PG100 or ASTM D41 primer applied to stress plates Cap Ply: Polyflex SA P FR or PolystickTU P, self -adhering, self -adhering and back -nailed max.12-inch o.c. using FBC HVHZ Approved nails and tin caps (FBC HVHZ 1517.5). Surfacing: FBC HVHZ Approved mechanically attached tile roof system. Refer to Table 4 for tile stagging limitations. NENIO ETC, LLC. Evaluation Report 3m-PLVG-20-FBCER.A Certifrc to ojAutnonzation #32455 7- EDITION (2020) FBC HVHZ EVALUATION FL5259-R32 (HVHZ) Polyglass Roof Underlayments Revision 28: 12/21/2020 Page 9 of 11 ONEMO I etc. 6.3.13 Deck Type 1: Wood, Non -Insulated Deck Description: Min. 19/32" plywood or wood plank System Type E: Base sheet mechanically fastened to deck; underlayment adhered to base sheet Base Sheet: One or more plies of Elastobase, Elastobase P felt with a minimum 3-inch side lap and 6-inch end lap, mechanically fastened to deck. Fastening: Simplex MAXX Cap Fastener (NOA 18-1227.05), 8-inch o.c. at the lap -edges and 8-inch o.c. in three (3) equally spaced, staggered center rows. Primer: PG100 or ASTM D41 primer applied to stress plates Base Ply: (Optional) Polystick MTS Plus or Polystick XFR, self -adhering and back -nailed max. 12-inch o.c. using FBC HVHZ Approved nails and tin caps (FBC HVHZ 1517.5) Cap Ply: Polystick MTS Pius or Polystick XFR, self -adhering and back -nailed max. 12-inch o.c. using FBC HVHZ Approved nails and tin caps (FBC HVHZ 1517.5). Surfacing: FBC HVHZ Approved asphalt shingles, mechanically attached tile roof system, metal panels, metal shingles, slate, slate -type shingles, wood shakes or wood shingles. Refer to Table 4 for tile stagging limitations. 6.3.14 r Deck Type 1: Wood, Non -Insulated Deck Description: Min. 19/32" plywood or wood plank System Type E: Base sheet mechanically fastened to deck; underlayment adhered to base sheet Base Sheet: One or more plies of Elastobase, Elastobase P or FBC HVHZ Approved ASTM D226, Type II felt with a minimum 4-inch side lap and 6-inch end lap, mechanically fastened to deck. Fastening: Simplex MAXX Cap Fastener (NOA 18-1227.05), 8-inch o.c. at the lap -edges and 8-inch o.c. In three (3) equally spaced, staggered center rows. Primer: PG100 or ASTM D41 primer applied to stress plates Base Ply: (Optional) Polystick MTS, Plus or Polystick XFR, self -adhering and back -nailed max. 12-inch o.c. using FBC HVHZ Approved nails and tin caps (FBC HVHZ 1517.5) Cap Ply: Polystick TU Max, self -adhering and back -nailed max.12-inch o.c. using FBC HVHZ Approved nails and tin caps (FBC HVHZ 1517.5). Surfacing: FBC HVHZApproved mechanically attached tile roof system, metal panels, metal shingles, wood shakes orwoodshingles. Refer to Table 4 for tile stagging limitations. 6.3.15 1 Deck Type 1: Wood, Non -Insulated Deck Description: Min. 19/32" plywood or wood plank System Type E: Base sheet mechanically fastened to deck; underlayment adhered to base sheet Base Sheet: One or more plies of Elastobase, Elastobase P or FBC HVHZ Approved ASTM D226, Type II felt with a minimum 4-inch side lap and 6-inch end lap, mechanically fastened to deck. Fastening: Simplex MAXX Cap Fastener (NOA 18-1227.05), 8-inch o.c. at the lap -edges and 8-inch o.c. in three (3) equally spaced, staggered center rows. Primer: Base Ply: Cap Ply: Surfacing: NEMO ETC, LLC. Certlifkate OfAuthorfmtion p3Z455 PG100 or ASTM D41 primer applied to stress plates (Optional) Polystick MTS Plus or Polystick XFR, self -adhering and back -nailed max. 12-inch o.c. using FBC HVHZ Approved nails and tin caps (FBC HVHZ 1517.5) Polystick TU Plus, self -adhering and back -nailed max.12-inch o.c. using FBC HVHZ Approved nails and tin caps (FBC HVHZ 1517.5). FBC HVHZ Approved asphalt shingles, mechanically attached tile roof system, metal panels, metal shingles, wood shakes or wood shingles. Refer to Table 4 for tile stagging limitations. 7- EDITION (2020) FBC HVHZ EVALUATION Polyglass Roof Underlayments Evaluation Report 3m-PLYG-20-FBCER.A FL5259-R32(HVHZ) Revision 28: 1Z/21/2020 Page 10 of 11 6.3.16 Deck Type 1: Wood, Non -Insulated OONEMO I etc. Deck Description: Min. 19/32" plywood or wood plank System Type E: Base sheet mechanically fastened to deck; underlayment adhered to base sheet Base Sheet: One or more plies of Elastobase, Elastobase P or FBC HVHZ Approved ASTM D226, Type II felt with a minimum 4-inch side lap and 6-inch end lap, mechanically fastened to deck. Fastening: Simplex MAXX Cap Fastener (NOA 18-1227.05), 8-inch o.c. at the lap -edges and 8-inch o.c. in three (3) equally spaced, staggered center rows. Primer: PG100 or ASTM D41 primer applied to stress plates Base Ply: (Optional) Polystick MTS Plus, self -adhering and back -nailed max. 12-inch o.c. using FBC HVHZ Approved nails and tin caps (FBC HVHZ 1517.5) Cap Ply: PolystickTU Max or PolystickTU Plus, self -adhering and back -nailed max.12-inch o.c. using FBC HVHZ Approved nails and tin caps (FBC HVHZ 1517.5). Surfacing: FBC HVHZ Approved adhesive -set tile roof system. Refer to Table 3A for allowable tile adhesives and Table 4 for tile stagging limitations. 6.3.17 Deck Type 3: Structural concrete, non -insulated Deck Description: Min. 2,500 psi structural concrete System Type F: Underlayment adhered Primer: ASTM D41 Underlayment: Elastoflex S6 G applied in hot asphalt or Polyflex G torch -applied or Polyflex SA P, self -adhering Surfacing: FBC HVHZ Approved adhesive -set tile roof system. Refer to Table SA for allowable tile adhesives and Table 4 for tile stagging limitations. 6.3.18 1 Deck Type 3: Structural concrete, non -insulated Deck Description: Min. 2,500 psi structural concrete System Type F: Underlayment adhered Primer: ASTM D41 Base Ply: (Optional) Polystick MTS Plus, self -adhering Cap Ply: PolystickTU Max or PolystickTU Plus, self -adhering Surfacing: FBC HVHZ Approved adhesive -set tile roof system. Refer to Table 1A for allowable tile adhesives and Table 4 for tile stagging limitations. As required by the Building Official or Authority Having Jurisdiction to properly evaluate the installation of this product. Contact the named CIA entity for manufacturing facilities covered by F.A.C. Rule 61G20-3 CIA requirements. Refer to herein for products and production locations having met codified material standards. UL LLC—QUA9625; (414) 248-6409; Karen.buchmann@ul.com - END OF EVALUATION REPORT - NEMO ETC, LLC. Evaluation Report 3m-PLVG-20-FaCER.A Cerpfixote of Authorization N32455 7- EDITION (2020) FBC HVHZ EVALUATION FL52S9-R32 (HVHZ) Polyglass Roof Underlayments Revision 28: 12/21/2020 Page 11 of 11