HomeMy WebLinkAboutAPPROVED Kelly-Tamko 30# FL Approval.pdf2/23/2021
Florida Building Code Online
Business & Professional Regulation
KIS Home Log to User Registration Hot Topics Submit surcharge stats & Facts Publications Contact Us BCIS Site Map Links Sear&
b,y
r
Product Approval
USER: Public User
PrOdUCI Approval Menu > Product or Aggllcatign Search > Application List > Application Detail
FL # 19L12328-119
Application Type Revision
Code Version 2020
Application Status Approved
Comments
Archived
Product Manufacturer TAMKO Building Products LLC
Address/Phone/Email PO Box 97
Galena, KS 66739
(417) 624-6644 Ext 2305
kerri_eden@tamko.com
Authorized Signature Kerri Eden
kerri—eden@tamko.com
Technical Representative Kerri Eden
Address/Phone/Email PO Box 1404
Joplin, MO 64802
(417) 624-6644 Ext2305
kerri_eden@tamko.com
Quality Assurance Representative
Address/Phone/Email
Category Roofing
Subcategory Underlayments
Compliance Method Evaluation Report from a Florida Registered Architect or a Licensed Florida
Professional Engineer
Evaluation Report - Hardcapy Received
Florida Engineer or Architect Name who developed the Robert Nieminen
Evaluation Report
Florida License PE-59166
Quality Assurance Entity UL LLC
Quality Assurance Contract Expiration Date 10/18/2021
Validated By John W. Knezevich, PE
Validation Checklist - Hardcopy Received
Certificate of Independence
Referenced Standard and Year (of Standard)
Equivalence of Product Standards
Certified By
I1�2]1Z8 R9 C01 2020 01 COI NIEMINEN.pdf
Standard
ASTM D1970
ASTM D226
ASTM D6380
Year
2015
2009
2013
Sections from the Code
https:llw Av.Roridabuilding.org/prlpr_app_dtl.aspx?param=wGEVXQwtDgtF2AezuarjgOlAramDGm5elxgFDzaRb4t427TWXal7Bg%3d%3d 1/2
2/23/2021
Florida Building Code Online
Product Approval Method
Date Submitted
Date Validated
Date Pending FBC Approval
Date Approved
Method I. Option D
09/29/2020
10/D4/2020
10/12/2020
12/15/2020
FL is Model, Number or Description
Name
12328.1 TAMKO Roof Roof underlayments for use in FBC HVHZ jurisdictions.
Undedayments (HVHZ)
Limits of Use InstaRadon Instructions
Approved for use In HVHZ: Yes FL12328 R9 It 2020 09 29 FINAL ER TAMKO UNDERLAYM NTS HVHZ F t 3 8-
Approved for use outside HVHZ: No Bg..pdf
Impact Resistant: N/A Verified By: Robert Nleminen PE-59166
Design Pressure: N/A Created by Independent Third Party: Yes
Other: See ER Section 5 for Limits of Evaluation Reports
Use. . FL1232R Rq AF 2n7n nq 7q MNAl FR TAMtn I luneol evereerre ulruv el.vs-.o
12328.2 TAMKO Roof
Undertayments (NON-
HVHZ)
Limits of Use
Approved for use in HVHZ: No
Approved for use outside HVHZ: Yes
Impact Resistant: N/A
Design Pressure: N/A
Other: See ER Section 5 for Limits of
Use.
Created by Independent Third Party: Yes
Roof underlayments for use in FEC non-HVHZ jurisdictions.
Installation Instructions
EL12328 R9 II 2020 09 29 FINAL ER TAMKO UNDERLAYMENTS NON
HVHZ FL32328-R9 odf
Verified By: Robert Nieminen PE-59166
Created by Independent Third Party; Yes
,Evaluation Reports
FL12328 R9 AE 2020 09 29 FINAL ER TAMKO UNDERLAYMENTS NON
HVHZ FL12328-R9 pd
Created by Indepentlent Third Party: Yes
aack Hext
Contact Us :: 2601 slat stone Rdad Tallahassee FL 32399 Phone: 850-487-1$24
The State of Florida Is an WEED employer. Coovdaht 2007-2013 State of Florida :: PHvaw statement :: Accessibility statement :: Refund statement
Under Florida law, email addresses are public records. If you do not want your e-mail address released In response to a public-remn is request, do not send electronic
mall to this entity. Instead, contact the office by phone or by traditional mall. If you have any questions, please contact 850.487.1395. *Pursuant ro section 455.275(1),
Florida stalums, effective October 1, 2012, licensees licensed under Chapter 455, F.S. must provide Me Department with an email address If they have one. The emails
provided may be used for official communication with the licensee. However email addresses are public record. If you do not wish to supply a personal address, please
provide the Department with an email address which can be made available to the public To determine If you are a Ilcensee under Chapter 455, FS., please click hil .
Product Approval Accepts:
rn oil is R E
Credit Card
Safe
httpsJtwww.floddabuilding.org/pr/pr_app_dU.aspx?param=wGEVXQwtDgtF2AezuadgOlAmmDGm5elxgFDzaRb4t427TWXal7Bg%3d%3d 2/2
NEMO I etc.
Certificate Of Aurhoritation #32455
353 Christian Street, Unit #13
Oxford, CT 06478
(203)262-9245
ENGINEER EVALUATE TEST CONSULT
EVALUATION#•
TAMKO Building Products, LLC Evaluation Report 3m-TAM-20-FBCER.A-RO
PO Box 97 FL12328-R9
Galena, KS 66739 Date of Issuance:09/29/2020
(417)624-6644
SCOPE:
This Evaluation Report is issued under Rule 61G20-3 and the applicable rules and regulations governing the use of
construction materials in the State of Florida. The documentation submitted has been reviewed by Robert Nieminen,
P.E. for use of the product under the Florida Building Code. The products described herein have been evaluated for
compliance with the 71h Edition (2020) Florida Building Code sections noted herein.
DESCRIPTION: TAMKO Roof Underlayments
LABELING: Labeling shall be in accordance with the requirements of the Accredited Quality Assurance Agency noted
herein and FBC 1507.1.1.
CONTINUED COMPLIANCE: This Evaluation Report is valid until such time as the named product(s) changes, the referenced
Quality Assurance or production facility location(s) changes, or Code provisions that relate to the product(s) change.
Acceptance of our Evaluation Reports by the named client constitutes agreement to notify NEMO ETC, LLC of any
changes to the product(s), the Quality Assurance or the production facility location(s). NEMO ETC, LLC requires a
complete review of its Evaluation Report relative to updated Code requirements with each Code Cycle.
ADVERTISEMENT: The Florida Product Approval Number (FL#) preceded by the words "NEMOletc. Evaluated" may be
displayed in advertising literature. If any portion of the Evaluation Report is displayed, then it shall be done in its
entirety.
INSPECTION: Upon request, a copy of this entire Evaluation Report shall be provided to the user by the manufacturer or
its distributors and shall be available for inspection at the job site at the request of the Building Official.
This Evaluation Report consists of pages 1 through S.
Prepared by:
Robert l.M.Nieminen,P.E.
_-;°-'-
Florida Registration No. 59166, Florida DCA ANE1983
• - ^•/^, The laamile"alaplearinawuauthwizedbyRobers
- Nie Rno
ninen, E. on o9/29/2020. This does t serve as an
`"'^• ^' e�•
elenromcally signed d=mmt.
CERTIFICATION OF INDEPENDENCE:
1. NEMO ETC, LLC does not have, nor does it intend to acquire or will it acquire, a financial interest in any company manufacturing or
distributing products it evaluates.
2. NEMO ETC, LLC is not owned, operated or controlled by any company manufacturing or distributing products it evaluates.
3. Robert Nieminen, P.E. does not have nor will acquire, a financial interest in any company manufacturing or distributing products for
which the evaluation reports are being issued.
4. Robert Nieminen, P.E. does not have, nor will acquire, a financial interest in any other entity involved in the approval process of the
product.
S. This Is a building code evaluation. Neither NEMO ETC, LLC nor Robert Nieminen, P.E. are, in any way, the Designer of Record for any
project on which this Evaluation Report, or previous versions thereof, Is/was used for permitting or design guidance unless retained
specifically for that purpose.
02019. NEMO ETC, LLC
NNEMO etc.
ROOFING COMPONENT EVALUATION
Product Category: Roofing
Sub -Category: Underlayment
Compliance Statement: TAMKO Roof Underlayments, as produced by TAMKO Building Products LLC, have
demonstrated compliance with the following sections of the 7'h Edition (2020) Florida Building Code through testing
in accordance with the following Standards. Compliance is subject to the Installation Requirements and Limitations
/ Conditions of Use set forth herein.
STANDARDS:2. Section Prope Standard Year
1507.1.1 / R905.1.1 Material standard ASTM D226 2009
1507.1.1, 1507.2.4, 1507.2.9.2 / Material standard ASTM D1970 2015
R905.1.1, R905.2.8.2
1507.2.9.2, 1507.6.5 / R905.2.8.2, Material standard ASTM D6390 2013
R905.5.4
3. REFERENCES
Lnft
Ettamination
Reference
Date
PRI(TST5878)
ASTM D1970
TAP-388-02-01
10/04/2017
PRI (TST5878)
ASTM D226, Type II
TAP-420-02-01
04/19/2018
PRI (TST5878)
ASTM D1970
TAP-447-02-01
10/19/2018
PRI (TST5878)
ASTM D6380
847T0009
12/21/2019
PRI (TST5878)
ASTM D6380
947T00010
12/21/2019
PRI (TST5878)
ASTM 0226, Type II
TAP-351-02.01
04/25/2016
PRI (TST5878)
ASTM D226, Type II
TAP-351-02-02
05/04/2016
UL LLC(TST9628)
ASTM D226, Type 11
13CA12269
03/24/2014
UL LLC (QUA9625)
Quality Assurance
Service Confirmation
10/20/2020
UL LLC (QUA962S)
Quality Assurance
Florida BCIS
Current
M
4.1
4.2
4.3
4.4
4.5
4.6
4.7
PRODUCT
Product
Material Standard
Plant(s)
Description
No. 30 UL
ASTM D226, Type II
Joplin, MO
Asphalt -saturated organic felt
Green Cove Springs, FL
No. 30 ASTM
ASTM D226, Type II
Phillipsburg, KS
Asphalt -saturated organic felt
-TAM-FELT-
ASTM D226, Type II
Green Cove Springs, FL
Asphalt -saturated organic felt
Moisture Guard-
ASTM D1970
Joplin, MO
Self -adhering, fiberglass reinforced SOS
modified bitumen roof underlayment with a
Columbus, KS
mineral top surface.
TW Underlayment
ASTM 019701
Self -adhering, SOS modified bitumen roof
underlayment with a polymer -film top
surface.
TW Seam Tape
ASTM D1970
Columbus, KS
Self -adhering, SOS modified bitumen deck
seam -tape with a polymer -film top surface.
ASTM Slate Surfaced Roll
ASTM D6380,
Green Cove Springs, FL
Asphalt -saturated organic mat, coated on
Roofing
Class M, Type II
both sides with asphalt and surfaced with
granules.
Agreement berween purchaser and seller, asset forth in Section 4-3, Note 1 of ASTM D1970.15, should be established as to slip resistance of TW
Underlayment.
NEMO ETC, LLC
Evaluation Report 3m-TAM-I0-F8CER.A-R0
Cengkate olAuthwuana. e32455 7" EDITION (2020)FBC NON-HVHZ EVALUATION FL12328-R9
TAMKO Roof Underlayments Revision 0: 09/29/2020
Page 2 of 5
NNEMO etc
Product
Material Standard
PIaM(s)
Description
4.8
ASTM Tile Underlayment
ASTM D6380,
Green Cove Springs, FL
Asphalt -saturated organic felt, coated on
Class M. Type 11
both sides with asphalt and surfaced with
granules.
s
5.1 This is a building code evaluation. Neither NEMO ETC, LLC nor Robert Nieminen, P.E. are, in any way, the Designer
of Record for any project on which this Evaluation Report, or previous versions thereof, is/was used for permitting
or design guidance unless retained specifically for that purpose.
5.2 This Evaluation Report is not for use in FBC High Velocity Hurricane Zone jurisdictions (i.e., Broward and Miami -Dade
Counties).
5.3 This Evaluation Report pertains to above -deck roof components. Roof decks and structural members shall be in
accordance with FBC requirements to the satisfaction of the Authority Having Jurisdiction.
5.4 This Evaluation Report does not include evaluation of fire classification. Refer to FBC 1SOS for requirements and
limitations regarding roof assembly fire classification. Refer to FBC 2603 for requirements and limitations
concerning the use of foam plastic Insulation.
5.5 TAMKO Roof Underlayments may be used with any prepared roof cover where the product is specifically referenced
within FBC approval documents. If not listed, a request may be made to the Authority Having Jurisdiction for
approval based on this evaluation combined with supporting data for the prepared roof covering.
5.6 Allowable Roof Coven:
TAaF 1: RooF Com OPriONS
pay and Concrete Tile
slower
Asphalt
mew
wood
Underlayment
smrwws
1150 -3)
Sleta-Type
MMlanical
Adhe3Ne-
Varhaif
Shlhhgles
shingles
shall.
p3a71/
Shingles
Attach
set
(3g0 )
rysa7SJ
13517.71
(1m7J)
(15117!)
yes
Yet
Yes
Yes
yes
Yes
Yes
No. 30 UL
i
S,Ye� 1
No. 30 ASTM
Yes
res
Yes
Yes
Yes
Yes
Yes
Yes
sees6.1
se95e1
TAM -FELT'
Yes
No
No
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Moisture Guard"
Yes
No
No
No
No
Yes
[lam tm"s,
il"en anin.
1507 1.1.3/
1503.1.1.3/
eats.11.]I
R90ssasi
Yes
Yes
TW Underlayment
Yes
NO
No
Yes
Yes
Yes
uovit strips,
0"vit sins,
15071.1.3/
15071.1.3/
e9p5.1 Lit
stscsl1])
Yes
Yes
Yes
Yes
Yes
Yes
TW Seam Tape
Omntnn"s.
No
No
Loin, urms.
W.,n nnm.
11amritst""s.
8mm mien.
(pmt"M
I5011LL /
1503.1.1.1 /
1507113 /
1503.1.1 11
1503.I 131
1507.1 1 3 /
Ran,1 1.11
R90513.11
R905 3.1 11
e90].I 1.11
e905.IA 31
e905.1.1 a)
ASTM Slate Surfaced Roll
Yes
Yes
Roofing
Nwrr uneq
Ita" snra in l
No
No
No
No
No
No
pp ,prcml
ASTM Tile Underlayment
Yes
urrtq
res
16"sORet �n I.
No
No
No
No
No
No
Wy=,ni
NEMO ETC, LLC Evaluation Report 3m-TAM-20-FBCER.A.RO
Certificate of Authorlr00on 932455 7" EDITION (2020) FBC NON-HVHZ EVALUATION FL12328R9
TAMRO Roof Underlayments Revision 0: 09/29/2020
Page 3 of 5
NNEMOjetc.
5.6.1 No. 30 UL or No. 30 ASTM may be used as a mechanically attached anchor sheet followed by an asphalt -applied
ASTM Slate Surfaced Roll Roofing or ASTM Tile Underlayment.
5.7 Allowable Substrates:
TABLE 2: SuasTRATE Opnoars FOR ADHERED UNDERLAYMENTS
Underlayment
Application
Primer
Substrates
Moisture Guard• or TW Underlayment
self -adhering
(Optional) ASTM D41
plywood
None
No. 30 UL, No. 30 ASTM or TAM -FELT*
TW Seam Tape
self -adhering
(Optional) ASTM D41
plywood
ASTM Slate Surfaced Roll Roofing or
ASTM Tile Underlayment
hot asphalt
None
No. 30 UL, No. 30 ASTM or TAM -FELT•
5.8 Attachment Limitations:
5.8.1 For use under mechanically attached NON -TILE prepared roof coverings, attachment shall be in accordance with the
manufacturers installation instructions, but — for mechanically attached underlayments or base sheets - not less
than FBC 1507.1.1 or R905.1.1.
5.8.2 For use under tile roof systems, attachment shall be in accordance with the manufacturer's installation instructions,
but — for mechanically attached base sheets - not less than:
• FRSA/TRI Florida High Wind Concrete and Clay Roof 771le Installation Manual, Sixth Edition, Appendix A, Table
1 (for Two -Ply Asphalt Applied Hot Mop Underlayment)
5.9 Exposure Limitations:
TABLE 3: EILPOSURE LiMTTATIONs
Underlayment Prepared Roof Cover Maximum Exposure (days)*
Installation Type
No. 30 UL, No. 30 ASTM, TAM -FELT•
Moisture Guard•, TW Underlayment, TW Seam Tape Any 30
ASTM Slate Surfaced Roll Roofing, ASTM Tile Underlayment
•Maximum exposure shall not exceed the manufacturer's recommendations, which may be less than 30 days.
5.10 Tile Slippage Limitations: When loading roof tiles on the underlayment in direct -deck tile roof assemblies, the tile
shall be staged atop battens during loading of the roof tiles.
6.1 TAMKO Roof Underlayments shall be installed in accordance with TAMKO Building Products LLC installation
instructions subject to the Limitations set forth in Section 5 herein and the specifics noted below.
6.2 Re -fasten any loose decking panels, and check for protruding nail heads. Sweep the substrate thoroughly to remove
any dust and debris prior to application, and prime the substrate (if applicable).
6.3 No. 30 UL, No. 30 ASTM:
6.3.1 Non -Tile Applications:
Shall be installed in compliance with requirements for an approved mechanically attached underlayment (ASTM
D226, Type I I) in FBC Table 1507.1.1.1 or FBC Residential Table R905.1.1.1 for the type of prepared roof covering to
be installed, and the manufacturer's installation instructions. FBC requirements take precedence over the
manufacturer's installation instructions.
NEMO ETC, LLC Evaluation Report 3m-TAM-20-FBCER.A.RO
Cem/cate of Authariratlan a32455 7°EDITIoN(2020)FBC NON-HVHZ EVALUATION FL12328-R9
TAMKO Roof Undedaymenfs Revislan 0: 09/29/2020
Page 4 of 5
ONEMOletc.
6.3.2 Tile Applications:
No. 30 UL or No. 30 ASTM are limited to use as a mechanically attached base sheet in the "TWO-PLY SYSTEM" from
FRSA/TRI Florida High Wind Concrete and Clay Roof Tile Installation Manual, Sixth Edition, followed by ASTM Slate
Surfaced Roll Roofing, ASTM Tile Underlayment applied in hot asphalt, or other FBC Approved hot -asphalt applied
cap sheet. Refer to FRSA/Ml, Sixth Edition, Appendix A, Table 1 for attachment requirements.
6A TAM-FELr:
6.4.1 Non -Tile Applications:
Shall be installed in compliance with requirements for an approved mechanically attached underlayment (ASTM
D226, Type 11) in FBC Table 1507.1.1.1 or FBC Residential Table R905.1.1.1 for the type of prepared roof covering to
be installed, and the manufacturer's installation instructions. FBC requirements take precedence over the
manufacturer's installation instructions.
6S Mohture Guard`, TW Underlayment:
6.5.1 Shall be installed in compliance with requirements for an approved self -adhering underlayment (ASTM D1970) in
FBC 1507.1.1.1 or 1S07.1.1.3 or FBC Residential R905.1.1.1 or R905.1.1.3 for the type of prepared roof covering to
be installed, and the manufacturer's installation instructions.
When installed over a mechanically attached, FBC Approved ASTM D226 Type II felt, the felt shall be fastened in
accordance with FBC 1507.1.1 or R905.1.1.
6.6 ASTM Slate Surfaced Roll Roofing, ASTM Tile Underlayment:
6.6.1 Tile Applications
ASTM Slate Surfaced Roll Roofing and ASTM Tile Underlayment are limited to use as the Hot Asphalt applied "Cap
Sheet" in the "TWO-PLY SYSTEM" from FRSA/TRI Florida High Wind Concrete and Clay Roof Tile Installation Manual,
Sixth Edition.
Refer to Section S.8.2 for attachment limitations.
Refer to Section 5.10 for tile staging limitations.
6.6.2 Valley Liner:
ASTM Slate Surfaced Roll Roofing and ASTM Tile Underlayment are acceptable for use as a valley liner in accordance
with FBC 1507.2.9.2 or FBC Residential R90S.2.8.2. Installation shall be in accordance with the manufacturer's
instructions before applying shingles.
As required by the Building Official or Authority Having Jurisdiction in order to properly evaluate the installation of
this product.
Contact the named CIA entity for manufacturing facilities covered by F.A.C. Rule 611320-3 CIA requirements. Refer
to Section 4 herein for products and production locations having met codified material standards.
9. QUALITY AssURANCE ENTITY:
UL LLC—QUA9625; (414) 248-6409; Karen buchmann;___d com
END OF EVALUATION REPORT -
NEMO ETC, LLC Evaluation Report 3m-TAM-204RCER.A-RO
Certificate of Autnonlanon 932455 7" EDITION (2020) FBC NON-HVHZ EVALUATION FL12328 R9
TAMKO Roof Underfayments Revision 0: D9/29/2020
Page 5 of 5