HomeMy WebLinkAboutPermit Appl for 3905 Avenue O AdditionalST,, LUCIE WORKS
Section A {General Information)
Master Permit No.
Contractors Name: One Construction & Roofinl
process Rio.
r
contractors License # CCC,.l 330623
JobAddres 3905 Avenue O Fort Pierce, FI 34947
I� Low Slope
Asphaltic Shingles
Q New roof
❑ Repair
Low Slope Roof Area (SF) 180 sq. ft
ROOF CATEGORY
0 Mechanically Fastened Tide
C3 Metal Panel/Shingles
0 Prescriptive BUR -RCS 150
Roof ROOF TYPE..
❑ Maintenance
ROOF SYSTEM INFORMATION
[3 Mortar/Adhesive Set Tiles
0Wood Shingles/Shakes
19 Reroofing
Steep Sloped Roof Area (SF) 1440 sq ft
C] Recovering
Total (SF) 1620 sq. ft.
sqw--9�
Section B (Roof Phan)
Sketch Roof Plan: Illustrate all levels and sections, roof drains, scuppers, overflow suppers and overflow drains.
include dimensions of sections and bevels, clearly identify dimensions of elevated pressure zones and location of parapets.
IF
ST,4 LUCIE WORKS
Section C (Low Slope Roof)
Fill in specific roof assembly components and identify
manufacturer
(If a component is not used, identify as "NA")
System Manufacturer: NIA
Product Approval No.: NIA
Design Wind Pressures, From RAS 128 Or Calculations:
Zone 1'*-36-1 Zone 1: -36.1 Zone2: -47.7 Zone 3: -164.9
Max. Design Pressure, from the specific product approval
system: F1 1654-R27
Type: Plywood
Gauge Thickness: 19/32
Slope: 1.5112
Anchor/Base Sheet & No. df Ply(s):
N/A
Anchor/Base Sheet Fastener/Bonding Material:
NIA
Insulation Base Layer: N/A
Base Insuttation Size and Thickness: NIA
Base Insulation Fastener/Bonding Material:
NIA
Top Insulation layer: NSA
Top insulation Size and Thickness: N/A
Top insulation Fastener/Bonding Material:
NIA
Base Sheet(s) & No. of Ply(s): 0 )
Base Sheep fastener/Bonding Material:
Polyglass Elastoflex SA V 1 Peel & stick
Ply Sheets)' & No. of Ply(s):
N/A
Ply Sheet fastener/Bonding Material:
NIA
Top Ply: (1)
Top Ply Fastener/Bonding Material:
Polyglass Elastoflex SAP I Peel & Stick
Surfacing:
Fastener Spacing for Anchor/Base Sheet Attachment:
1 0 11 ft oc
Zone 1 oc @ Lap, # Rows... @
Zone 1* Lap,# Rows @ 0C
Zone 2:.--
' .. 0Z o n e 3 -E 4PENPEEkPL.F6dM-.M 0C @ Lap, # Rows. @ 0C
Number of Fasteners Per Insulation Board:
Zone 1': Zone Zone 2: Zone 3;
Illustrate Components Noted and Details as Applicable:
Woodblocking, Gutter, Edge Termination, Stripping,
Flashing,, Continuous Cleat, Cant Strip, Base Flashing,
Counterf lashing, Coping, Etc..
Indicate: Mean Rood Height,, Parapet Height, Height of Base
Flashing, Component Material, Material'Thickness, fastener
Type,, Fastener Spacing or Submit Manufacturers Details that
Comply with RAS 111 and Chapter 16. .
ST. LUCIE WORKS
Section D (Steep Slope Roof System)
Roof System Manufacturer: Tamko Building products
Notice of Acceptance Number:
FI # 18355-R6
Minimum Design Wind Pressures, If Applicable (From RAS 127 0r Calculations): .
Zon : - Z - .2 Zone 2n: - 0-2 Zone - . Zone3e: - •2 Zone - .
Roof Slope:3 12
Ridge Ventilafion?
NIA
Deck Type. 19/32 CDX Ply4.
wood
Type UnderlWment: � Tri-built / peel &stack
Insulaton:
Fire Barrier..
Mean Roof Height.V 121 '
Fastener Type & Spacing:
0-
Ad hesive Type*. Nan
\ Type Cap Sheet:
7
Roof Covering:
1-1 'fx . 120 Coil Nails 16 nails pattern = 1-2-2-1
Shingle Tamko
Type & Size Drip
Edge:
a
''x 2" / Aluminum
V