HomeMy WebLinkAboutPermit Appl for 3905 Avenue O AdditionalST,, LUCIE WORKS Section A {General Information) Master Permit No. Contractors Name: One Construction & Roofinl process Rio. r contractors License # CCC,.l 330623 JobAddres 3905 Avenue O Fort Pierce, FI 34947 I� Low Slope Asphaltic Shingles Q New roof ❑ Repair Low Slope Roof Area (SF) 180 sq. ft ROOF CATEGORY 0 Mechanically Fastened Tide C3 Metal Panel/Shingles 0 Prescriptive BUR -RCS 150 Roof ROOF TYPE.. ❑ Maintenance ROOF SYSTEM INFORMATION [3 Mortar/Adhesive Set Tiles 0Wood Shingles/Shakes 19 Reroofing Steep Sloped Roof Area (SF) 1440 sq ft C] Recovering Total (SF) 1620 sq. ft. sqw­--9� Section B (Roof Phan) Sketch Roof Plan: Illustrate all levels and sections, roof drains, scuppers, overflow suppers and overflow drains. include dimensions of sections and bevels, clearly identify dimensions of elevated pressure zones and location of parapets. IF ST,4 LUCIE WORKS Section C (Low Slope Roof) Fill in specific roof assembly components and identify manufacturer (If a component is not used, identify as "NA") System Manufacturer: NIA Product Approval No.: NIA Design Wind Pressures, From RAS 128 Or Calculations: Zone 1'*-36-1 Zone 1: -36.1 Zone2: -47.7 Zone 3: -164.9 Max. Design Pressure, from the specific product approval system: F1 1654-R27 Type: Plywood Gauge Thickness: 19/32 Slope: 1.5112 Anchor/Base Sheet & No. df Ply(s): N/A Anchor/Base Sheet Fastener/Bonding Material: NIA Insulation Base Layer: N/A Base Insuttation Size and Thickness: NIA Base Insulation Fastener/Bonding Material: NIA Top Insulation layer: NSA Top insulation Size and Thickness: N/A Top insulation Fastener/Bonding Material: NIA Base Sheet(s) & No. of Ply(s): 0 ) Base Sheep fastener/Bonding Material: Polyglass Elastoflex SA V 1 Peel & stick Ply Sheets)' & No. of Ply(s): N/A Ply Sheet fastener/Bonding Material: NIA Top Ply: (1) Top Ply Fastener/Bonding Material: Polyglass Elastoflex SAP I Peel & Stick Surfacing: Fastener Spacing for Anchor/Base Sheet Attachment: 1 0 11 ft oc Zone 1 oc @ Lap, # Rows... @ Zone 1* Lap,# Rows @ 0C Zone 2:.-- ' .. 0Z o n e 3 -E 4PENPEEkPL.F6dM-.M 0C @ Lap, # Rows. @ 0C Number of Fasteners Per Insulation Board: Zone 1': Zone Zone 2: Zone 3; Illustrate Components Noted and Details as Applicable: Woodblocking, Gutter, Edge Termination, Stripping, Flashing,, Continuous Cleat, Cant Strip, Base Flashing, Counterf lashing, Coping, Etc.. Indicate: Mean Rood Height,, Parapet Height, Height of Base Flashing, Component Material, Material'Thickness, fastener Type,, Fastener Spacing or Submit Manufacturers Details that Comply with RAS 111 and Chapter 16. . ST. LUCIE WORKS Section D (Steep Slope Roof System) Roof System Manufacturer: Tamko Building products Notice of Acceptance Number: FI # 18355-R6 Minimum Design Wind Pressures, If Applicable (From RAS 127 0r Calculations): . Zon : - Z - .2 Zone 2n: - 0-2 Zone - . Zone3e: - •2 Zone - . Roof Slope:3 12 Ridge Ventilafion? NIA Deck Type. 19/32 CDX Ply4. wood Type UnderlWment: � Tri-built / peel &stack Insulaton: Fire Barrier.. Mean Roof Height.V 121 ' Fastener Type & Spacing: 0- Ad hesive Type*. Nan \ Type Cap Sheet: 7 Roof Covering: 1-1 'fx . 120 Coil Nails 16 nails pattern = 1-2-2-1 Shingle Tamko Type & Size Drip Edge: a ''x 2" / Aluminum V