HomeMy WebLinkAboutcompaction testA Universal
Engineering
Sciences
Company
UES Project No: 3310.2100034.0000
o Wrkorder No: 236441-1
Report Date: 06/11 /2021
607 Northwest Commodity Cove, Port St. Lucie, FL 34986 - P: NO IN - F: 772-924-3580
In -Place Density Test Report
Client: K. HOVNANIAN HOMES
3601 Quantum Blvd.
Boynton Beach, FL 33426
Project: CMT/CSD Aspire at Waterstone
5226 Arming Place, Ft. Pierce, St. Lucie County, FL 34951
Area Tested: Lot 36 - 5129 Arming Place, Ft Pierce
Material: Backfill
Reference Datum: 0 =Top of Fill
The tests below meet the 95% minimum compaction requirement.
UES Technician: Mark Rogers
Date Tested: 06/11/2021
Type of Test:
Field: AS
TM
D-6938 Nuclear Gauge Method
Laboratory: ASTM D1557 Modified Proctor
Maximum
Optimum
Field Dry
Field
Soil
Pass
Test
Density
Moisture
Density
Moisture
Compaction
or
No.
Location of Test
Range
(pcf)
N
(pcf)
N
N
Fail
1
Northeast corner of lot
0-1 ft
120.1
10.9
116.0
10.4
97
Pass
2
Southwest corner of lot
0-1 ft
120.1
10.9
116.0
10.6
97
Pass
3
Center of lot
0-1 ft
120.1
10.9
115.9
10.6
97
Pass
Remarks: Above stripped surface 1-2', 2-3' HCP=60+, > 95 % Compaction , PASS. HCP tests are empirically correlated to the
relative density of the soil.
Permit: 2103-0633
Reviewed By
GFA International, Inc
FBPE Registry No.4930
JohnDigitally signed
by John Kent
Date:
2021.06.11
13:17*18-04'00'
John Kent
Senior Project Engineer
STATE OF FLORIDA
Professional Engineer No. 63218
This item has been digitally signed and sealed by John Kenton the
date adjacent to the seal. Printed copies of this document are not
considered signed and sealed and the signature must be verified on
any electronic copies.
To establish a mutual protection to Universal's clients, the Public and ourselves, all reports are submitted as confidential property of our clients and
authorization for publication of statements, conclusions or extracts from or regarding Universal's reports is reserved pending our written approval.
Page 1