HomeMy WebLinkAboutApproved Roof Prod Approval FL #11671.1 R4 Product Evaluation Report Mid Florida Metal Roofing Supply, Inc. Min. 26 Ga. 5V-Crimp Roof Panel over 15/32” Plywood Florida Product Approval #11671.1 R4 Florida Building Code 2020 Per Rule 61G20-3 Method: 1 –D Category: Roofing Subcategory: Metal Roofing Compliance Method: 61G20-3.005(1)(d) NON HVHZ Product Manufacturer: Mid Florida Metal Roofing Supply, Inc. 28328 County Road 561 Tavares, Florida 32778 (352) 742-7070 Engineer Evaluator: Johnathan Green, P.E. #88223 Florida Evaluation ANE ID: 12901 Validator: Brian Jaks P.E. #70159 Contents: Evaluation Report Pages 1 – 4 FL #11671.1 R4 Compliance Statement: The product as described in this report has demonstrated compliance with the Florida Building Code 2020, Sections 1504.3.2, 1504.7. Product Description: 5V Crimp Roof Panel, Min. 26 Ga. Steel, 24” coverage, through fastened roof panel over Min. 15/32” APA Plywood decking. Non-structural Application. Panel Material/Standards: Material: Min. 26 Ga. Steel, ASTM A792 Grade 50 conforming to Florida Building Code 2020 Section 1507.4.3. Paint finish optional. Yield Strength: Min. 50.0 ksi Corrosion Resistance: Panel Material shall comply with Florida Building Code 2020, Section 1507.4.3. Panel Dimension(s): Thickness: 0.018” min. Width: 24” maximum coverage Rib Height: 3/8” tall ribs Panel Fastener: #9-15 x 1-1/2” WoodZac with sealing washing or approved equal; fasteners through panel ribs. Fastener penetration – 1/4" minimum penetration through plywood. Corrosion Resistance: Per Florida Building Code 2020, Section 1507.4.4. Substrate Description: Min. 15/32” thick, APA Rated plywood over supports at maximum 24” O.C. Design of plywood and plywood supports are outside the scope of this evaluation. Substrate must be designed in accordance w/ Florida Building Code 2020. Allowable Design Uplift Pressures: Table "A" Maximum Total Uplift Design Pressure: 108.5 psf 156.5 psf Fastener Pattern: 12”-12” 12”-12” Fastener Spacing: 12” O.C. 6” O.C. *Design Pressure includes a Safety Factor = 2.0. FL #11671.1 R4 Code Compliance: The product described herein has demonstrated compliance with The Florida Building Code 2020, Section 1504.3.2, 1504.7. Evaluation Report Scope: The product evaluation is limited to compliance with the structural wind load requirements of the Florida Building Code 2020, as relates to Rule 61G20-3. Performance Standards: The product described herein has demonstrated compliance with: ▪ UL 580-06 - Test for Uplift Resistance of Roof Assemblies ▪ UL 1897-2012 - Uplift Test for Roof Covering Systems Reference Data: 1. UL 580-94 / 1897-98 Uplift Test Force Engineering & Testing, Inc. Report No. 194-0135T-07E-G Dated 12/15/2008 3. Certificate of Independence By Johnathan Green, P.E. (No. 88223) @ Force Engineering & Testing (FBC Organization # ANE ID: 12901) Test Standard Equivalency: The UL 580-94 test standard is equivalent to UL 580-06 test standard. The UL 1897-98 test standard is equivalent to the UL 1897-2012 test standard. Quality Assurance Entity: The manufacturer has established compliance of roof panel products in accordance with the Florida Building Code and Rule 61G20-3.005 (3) for manufacturing under a quality assurance program audited by an approved quality assurance entity. Minimum Slope Range: Minimum Slope shall comply with Florida Building Code 2020, including Section 1507.4.2 and in accordance with Manufacturers recommendations. For slopes less than 3:12, lap sealant must be used in the panel side laps. Installation: Install per manufacturer’s recommended details. FL #11671.1 R4 Underlayment: Per Florida Building Code 2020, Section 1507.1.1 and manufacturer’s installation guidelines. Roof Panel Fire Classification: Fire classification is not part of this acceptance. Shear Diaphragm: Shear diaphragm values are outside the scope of this report. Design Procedure: Based on the dimensions of the structure, appropriate wind loads are determined using Chapter 16 of the Florida Building Code 2020 for roof cladding wind loads. These component wind loads for roof cladding are compared to the allowable pressure listed above. The design professional shall select the appropriate erection details to reference in his drawings for proper fastener attachment to his structure and analyze the panel fasteners for pullout and pullover. Support framing must be in compliance with Florida Building Code 2020 Chapter 22 for steel, Chapter 23 for wood and Chapter 16 for structural loading. FL #11671.1 R4