HomeMy WebLinkAboutTarco NOAan
14II0MI>&DADR COXXTY
DEPARTNIBNT OF REGIILATORY AND ECONOMIC RESOURCES (S=)
PRODUCT CONTROL SECTION
118D5 5w 26 Street, Boom 269
BOARD AND CODE ADNWISTRATION DMUON
Miami, Florida 33175-2474
NOTICE OF ACCEPTANCE (NOA)
T (786) 315-2M F (786) 315-2599
ww►►.roiaroldatle:.aov�exorarw
Tareo Specialty Products, Inc.
One Information Way, Suite 22S
Little Rock, AR 72202
SCOPE:
This NOA is being issued under the applicable rules and regulations governing the use of construction materials. The
documentation submitted has been reviewed and accepted by Miami Dade County RER -Product Control Section to be
used in Miami Dade County and other areas where allowed by the Authority Having Jurisdiction (AHJ).
This NOA shall not be valid after the wgdrati.on date stated below. The Miami Dade County Product Control Section
(inMiamiDade County) and/or the AHJ (in areas other than.Miami Dade County) reserve the right to have this
product or material tested fur quality assurance purposes. If this product or material fails to perform in the accepted
manner, the manufacturer will incur the expense of such testing and the AHJ may immediately revolve, modify, or
suspend the use of such product or material within their jurisdiction. RER reserves the right to revoke this acceptance,
if it is determined by Miami Dade County Product Control Section that this product or material fails to meet the
requirements of the applicable building code.
This product is approved as described herein, and has been designed to comply with the Florida Building Code
including the high Velocity Hurricane Zone of the Florida Building Code.
DESCRIPTION: Tarco Roofing Membranes and Underlayments
LABELING: Each unit shall bear a permanent label with the manufacturer's name or logo, city, state and following
statement: "Miarni-Dade County Product Control Approved", unless otherwise noted herein.
RENEWAL of this NOA shall be considered after a renewal application has been filed and there has been no change
in the applicable building code negatively of tcting the performance of this product.
TERMINATION of this NOA will occur after the expiration date or if theta has been a revision or change in the
materials, use, and/or manufacture of the product or process. Misuse of this NOA as an endorsement of any product,
for sales, advertising or any other purposes shall automatically terminate this NOA. Failure to comply with any section
of this NOA shall be cause for termination and removal of NOA.
ADVERTISEMENT: The NOA number preceded by the words Miami -Dade County, Florida, and followed
by the expiration date may be displayed in advertising literature. If any portion of the NOA is displayed, then
It shall be done in its entirety.
INSPECITON: A copy of this entire NOA shall be provided to the user by the mamlfactuaer or its distributors and
shall be available for inspection at the job site at the request of the Building Official.
This NOA renews NOA No. 12-0420.02 and consists ofpages1 t`b ",' 15�1
The submitted documentation was reviewed by Alex Tigera. -
APPRbYED,
NOA No.: 16.1116.09
,kipiration Date: OYW22
Approval Date„ 01/12/17
Page 1 of 1S
ROOFING COMPONENT APPROVAL
Cateeorv: Rooting
Snb-Cater=orv: Underlayrnent
Material: Asphalt, SBS, Polyester
SCOPE:
This acceptance is for Terco Roofing Membrane and Underlayments, for use with approved prepared roof
assemblies where the applicable TAS/ASTM specific underlayment is specified and installed with prescribed approved
adhesives, fasteners and fastener densities, as described in this Notice of Acceptance; designed to comply with the
Florida Building Code, including the High Velocity Hurricane Zone of the Florida Building Code.
TRADE NAMES OF PRODUCTS MANUFACTURED OR LABELED 13Y APPLICANT:
Product Dimensions Test S ecification Product Description
30# ASTM 3' x 72"tolls ASTM D226 Type li Asphalt saturated felt underlaymenr
Specification Velt
Manufacturing
Location 01 & #2
EasyLay
3' x 133' 4" rolls ASTM D226 Type II Sheet material coulldising a polyester
Manufacturing
substrate coated with bituminous coating for
Location #2
use as an underlayment in roofing
applications. Designed as a shingle and metal
roofing underlayment and for use in file
roofing assemblies when used with an
approved TAS 103 file underlayment cap
sheet.
Fiberglass Mineral
3' x 36'rolls ASTM D3909 Mineral surfaced glass fiber roinfioreed,
Surfaced Roll
asphalt coated roll roofing for hot mop or cold
Roofing
process application.
Manufacturing
Location #1
ASTM Organic Tile Tx 36'rolls AS TM D6380 Asphalt saturated granular surfaced felt
Underlayment Type II underlayment for hot mop application.
Manufacturing
Location #1
RasyMop SBS Tx 36'rolls TAS 104 Granular surfaced polyester reinforced, SBS
Manufacturing modified bituminous membrane for.hot mop or
Location #1 cold prrc ss k0jp irOfion. Designed as a tale
roefine #4"- �Y e .
1. v
nu"i cowgr - NOA N%:16.1116.09
' " 4piration Date: 01W22
Approval Date: 01/12/17
Page 2 of 15
Fast90 3' x 36' rolls TAS 103 Granular surfaced, asphalt -impregnated
Manufacturing ASTM D249 orgaudc felt reinforced, bituminous sheet
Location #1 ASTM D6380 material with a self-adhesive bottom layer, for
use as an underlayment in sloped roof
assemblies. Designed as a file roofing
underlayment.
PROW Tx 66'8" rolls
TAS 103 Fabric surfaced, fiberglass reinforced, SBS
Manufacturing
ASTM D 1970 modified bituminous sheet material with a
Location #1 & #2
self-adhesive bottom layer, for use as an
underlayment in sloped roof assemblies.
Designed as a shingle, tile and metal roofing
underlayment.
PS20W 3' x 66'8" rolls
ASTM D 1970 Film surfaced, fiberglass reinforced, SBS
Manufacturing
modified bituminous sheet material with a
Location #1 & #2
self-adhesive bottom layer, for use as an
underlayment in sloped roof assemblies.
Designed as a metal and shingle roofing
underlayment.
MS300
3' x 66'8" rolls
ASTM D 1970 Fine granular surfaced, fiberglass reinforced,
Manufacturing
3' x 33'4" rolls
bituminous sheet material with a self-adhesive
Location 01 & #2
bottom layer, for use as an underlayment in
sloped roof assemblies. Designed as an ice
and water shield, and a shingle roofing
underlayment.
SS400
3' x 66'8" rolls
ASTM D 1970 Smooth surfaced, fiberglass reinforced,
Manufacturing
3' x 33'4" rolls
bituminous sheet material with a self-adhesive
Location #1 & #2
bottom layer, for use as an uWadayment in
sloped roof assemblies. Designed as an ice
and water shield, and a shingle and metal
roofing underlayment.
NR5OORr
3' x 66'8" rolls
ASTM D 1970 Film surfaced, non reinforced, bituminous
Manufacturing
sheet material with a self-adhesive bottom
Location #3
layer, for use as an underlayment in sloped
roof assemblies. Designed as an ice and water
shield, and a shingle and metal roofing
underlayment.
MtAMMAoE�COUNTY NOA No.: 1&1116.09
+ Yarbstion Date: Owsw
Approval Date: 01/12/17
Page 3 of 15
MANUFACTURING LOCATION:
1. Greencastle, PA
2. Belton, TX
3. Coshocton, OH
EVIDENCE SUBmrrTED:
Test AVency Test Identifier Test NamelRF poPt Date
Atlantic & Car ibean Roof ACRC06-013 TAS 103 06/14/06
Consulting, LLC
PRI Asphalt Technologies
TOT-003-02-01
ASTM D226 Type H
08/22/02
TOT-029-02-01
TAS 110, ASTM D249 & D 6380
07/05/05
TOT-030-02-01
TAS 110, ASTM D249 & D 6380
07/05/05
TOT-041-02-01
TAS 110, ASTM D226 Type II
05/24/06
TOT-042-02-01
ASTM D4798 & ASTM G155
05/22/07
Tdaity I MD
T3580.10.06-2
TAS 103
10/26106
T3580.10.06
TAS 103, ASTM D6380
10/12/06
T30160.08.09-R1
ASTM D1970
10/12/10
T10550.07.08
ASTM D4798 & ASTM D 1970
07/30/08
T32530.08.10
ASTM D 1970
08/17/10
T33190.08.10
TAS 103
08/06/10
T43930.09.13-R2
TAS 104
09/11/13
T40790.04.12
ASTM D6380
04/06/12
T40780.04.12
ASTM D3909
04/06/12
T37610.07.11
TAS 114 D
07/29/11
IRT Arcon
IRT07-0006
ASTM D 1970
07/11/07
IRT 07-0036
ASTM D 1970
02/22/08
IRT08-0002
ASTM D1970
02122/08
""MADE rrY NOANo.: I&HI6.09
aspiration Date: 0MV22
Approval Date: OU12/17
Page 4 of 15
Af1'J3OVF,1D ?.sSJrIVEB-1p.S G :§#'t,i:lRf:t!J("._4`IOhY.1,J<:
Deck Type: See Installation Requirements and General Limitations below.
Deck Description: See Installation Requirements and General. Limitations below.
System E(1): See Installation Requiremems and General Limitations below.
INSTALLATION REQUIREMENTS - 30# ASTM SPEcmcATION FELT:
L 30# ASTM Specification Felt shall be installed in strict compliance with applicable Building Codes.
2. Observe and Comply with roofing practices and guidelines as outlined by the National Roofing Contractors
Associations (NRCA) when installing 30# Felt.
3. During installation of 30# Felt, comply with Occupational Safety and Health Administration (OSHA) safety
standards; use common sense measures and adequate safety precautions to prevent accidents.
4. 30# ASTM Specification Felt shall be installed with a minimum 4" end lap in a shingle layer fashion and
fastened as requited by applicable system assemblies NOA or FBC 15182.
GENERAL LIMITATIONS - 30# ASTM SPZCMC.ATION FELT:
L Fire classificationis not part of this acceptance; refer to a current Approved Roofing Materials Directory for fire
ratings of this product.
2. This acceptance is for prepared roofing applications. Minimum deck requirements shall be in compliance with
applicable building code.
3. 30# ASTM Specification Felt may be used with any approved roof covering Notice of Acceptance listing
ASTM D226 Type H felt as a component part of an assembly in the Notice of Acceptance,
4. All products lined herein shall have a quality assmgnce audit in accordance with the Florida Building Code and
Rule 61 G20-3 of the Florida Administtadve Code.
MUMMAD' zaurrrr NOA No.:16-1116A!
Expiration Date: OL25M
Approval Date: OMV17
pages of is
APPROVED ASSEMBLIES - EASYLAY:
Deck Type 1: Wood, Non -insulated
Deck Description: '9/32" or greater plywood or wood plank
System E(2): Anchor sheet mechanically fastened to deck.
Anchor Sheet: One or more plies of EasyLay uuderlayment, with a minimum 4" wide side lap and a minimum
8" wide end lap, mechanically fastened to deck.
Fastening: Approved nails and tin caps 6" o.c. within lap and two equally spaced staggered rows 12" o.c.
in the field (for Anchor/B ase sheet)..
Surfacing: Approved Roof Assemblies in lieu of FBC pencribed ASTM D 226 Type II felt
INSTALLATION REQUIREMENTS - EASYLAY:
I. EasyLay shall be installed in strict compliance with applicable Building Codes.
2. Observe and comply with looflng practices and guidelines as outlined by the National Roofiing Contractors
Associations (NRCA) when installing EasyLay.
3. During installation, comply with Occupational Safety and Health Administration (OSHA) safety standards; use
common sense measures and adequate safety precautions to prevent accidents.
4. EasyLay shall be acceptable for use with asphaltic shingles, wood shakes and shingles, quarry slate, the and
metal roofing assemblies.
5. Re -fasten any loose decking panels, and check for protruding nail heads prior to the application of EasyLay.
6. Place a M width piece of EasyLay, parallel to the eave (low) edge of the roof.
7. Unroll EasyLay 2 to 3 fbet, with the lay lines facing up, and position the and of it to the edge of the cave and
rake.
8. Install a few fasteners at the top, near the rake, and roll out the sheet to a manageable length.
9. Pull, straighten and align the sheet so that any wrinkles are eliminated and the sheet is even with the cave edge.
10. EasyLay shall be fastened with approved roofing nails and tin caps or approved cap nails, driven by hand or
pneumatically, spaced 6" o.c. at all laps in the center of the seam area, and two staggervd lows fastened 12"
o.c. in the field of the sheet.
11. When installing nails, apply so that the head of the nail is flush with the EasyLay surface, without cutting into
the EasyLay surface.
12. Fastening shall be done from the top to avoid walking or kneeling on unsecured sheet.
13. Continue on to the end of the substrate and fasten down.
14. Align the next roll over the preceding sheet so as to form a minimum 4" overlap.
15. Theninstall the just placed sheet, per instructions above.
16. The bottom of the second course of EasyLay shall lay on top of the $tst course so that any water will flow over
the top of EasyLay. e
17. Apply subsequent sheets in the same manner, with 4" sift lipsAfid-5' or,.dt_apa aver the preceding sheets.
1S. When the top course is reached, lap about 6" of EasyLay over the ridge.
rM►Qaus couMY NOA No.: 16-1116 09
• ► Expiration Date: Ol/25122
Approval Date: 01/12/17
Page 6 of 15
19. install EasyLay a minimum of 6" up any vertical surfaces.
20. Stagger the end laps a minimum of IS "iiom the preceding course.
21. After installing EasyLay on the field of the roof; install drip edge at the eaves (ifused).
22. When applying EasyLay in the valley, start at the low point and work to the nigh point, rolling the membrane
from the center outward in each direction. Make sure there are no rips or large wrinkles in the EasyLay.
23. Before applying horizontal sections of EasyLay, install a vertical length of EasyLay down the center of the
valley.
24. Several sections of EasyLay can be used, but be certain to overlap the higher sections several inches so any
water will flow over the top of the sheet.
25. EasyLay undeslayment in the valley areas must be covered with code prescribed metal or other approved valley
lining material.
26. Apply a minimum 1116" thick uniform layer of SBS trowel grade modified flashing cement to water proof
areas of EasyLay where any cuts or tears have occurred. Seams or j oinis may require the application of an SB S
trowel grade modified flashing cement.
27. Flash vent pipes, stacks, chimneys and penetrations in compliance with Roof Assembly current
Product Control Notice of Acceptance and applicable Building Code.
GENERAL LmTATIUNS - EASYLAY:
1. Fire classification is not part of this acceptance; refer to a current Approved Roofing Materials Directory for fire
ratings of this product.
2. This acceptance is for prepared roofing applications. Minimum deckrequitements shall be in compliance with
applicable building code.
3. EasyLay shall be applied to a clean and dry surface.
4. EasyLay shall not be torched or hot mopped to. Refer to mamrfacturer's published literature for additional
information.
EasyLay shall not be used on slopes less than 2:12, unless the slope is acceptable to the weather resistant
covering. In general, on slopes less than 4:12, a double layer of EasyLay is recommended.
Double layer application is best achieved by using 19" side laps, making sure the side laps are `shingled in' to
shed water.
6. When installing EasyLay, the roof system must include proper ventilation.
7. Refer to prepared roofing system Product Control Notice of Acceptance for listed approval of EasyLay with
specific prepared roofing products. EasyLay may be used with any approved roof covering Notice of
Acceptance listing ASTM D 226 Type 11 felt as a component part of an assembly in the Notice of Acceptance.
S. All products listed herein shall have a quality assurance audit in accordance with the Florida Building Code and
Rule 61 G20-3 of the Florida Administrative Code.
9. EasyLay shall not be left exposed for longer than 30 days after application.
10. The manufacturer reserves the right to change productpxposure perod, at ary time; not to exceed the preceding
maximum time limitations.
MImMI#7u4DECOUNTY NOA No.: 16-1116.09
1 Expiration Date: OlIM22
Approval Date: O1112117
Page 7 of 15
APPROVED ASSEMBLIES - FIBERGLASS MINERAL SURFACED ROLL ROOFING:
Deck Type: See Installation Requirements and General Limitations below.
Deck Description: See Installation Requirements and General Limitations below.
System E(3): See Installation Requirements and General Limitations below.
INSTALLATION REQUIREMENTS — FIBERGLASS MINERAL SURFACED ROLL ROOFING:
L Fiberglass Mineral. Surfaced Roll Roofing may be used with any approved roof covering Notice of Acceptance
listing Fiberglass Mineral Surfaced Roll Roofing as a component part of an assembly in the Notice of
Acceptance or wherever a ASTM D3909 roof membrane is specified and installed with prescribed approved
asphalt, adhesives, fasteners and fastener densities per applicable FBC requirements.
2. Observe and comply with roofing practices and guidelines as outlined by the National Roofing Contractors
Associations (NRCA) when installing Fiberglass Mineral. Surfaced Roll Roofing.
3. During installation of Fiberglass Mineral. Surfaced Roll Roofing, comply with Occupational Safety and Health
Administration (OSHA) safety standards; use common sense measures and adequate safety precautions to
prevent accidents.
GENERAL LmTATIONS — FIBERGLASS MINERAL SURFACED ROLL ROOFING:
1. Fire classification is not part of this acceptance; infer to a current Approved Roofing Materials Directory for fire
ratings of this product.
2. This acceptance is for prepared tooling applications. Minimum deck requirements shall be in compliance with
applicable building codes.
3. All products lined herein shall have a quality assurance audit in accordance with the Florida Building Code and
Rule 61G20-3 of the Florida Administrative Code.
f71wMFr]AF)E COI,��rT1r
NOA N%:16-1116.09
EViration Date: 01125122
Approval Date: OV12117
Pages of 15
APPROVED ASSEMBLIES - ASTM ORGANIC TELE UNDERLAYIIIENT:
Deck Type: See Installation Requirements and General Limitations below.
Deck Description: See Installation Requirements and General Limitations below.
System.E(4): See Installation Requirements and General Limitations below.
INSTALLATION REQUIREMENTS -ASTM ORGANIC THE UNDERLAYMENT:
L ASTM Organic Tile Underlayment may be used with any approved roof covering Notice of Acceptance listing
ASTM Organic Tile Underlayment as a component part of an assembly in the Notice of Acceptance or wherever
a ASTM D6380 roof membrane is specified and installed with prescribed approved asphalt, adhesives, fasteners
and fastener densities per applicable FBC requirements.
2. Observe and comply with roofing practices and guidelines as outlined by the National Roofing Contractors
Associations (NRCA) when installing ASTM Organic Tile Underiayment.
3. During installation of ASTM Organic Tile Underiayment, comply with Occupational Safety and Health
Administration (OSHA) safety standards; use common some measures and adequate safety precautions to
prevent accidents.
GENERAL LIMITATIONS - ASTM ORGANIC TILE UNDERLAYMENT:
I. Fire classification is not part of this acceptance; refer to a current Approved Roofing Materials Directory for fire
ratings of this product.
2. This acceptance is for prepared roofing applications. Minimum deck requirements shall be in compliance with
applicable building codes.
3. All products lised herein shall have a quality assurance audit in accordance with the Florida Building Code and
Rule 61 G20-3 of the Florida Administrative Code.
MMUM-DARE cfluwrr NOA No.: 16-1116.09
I' Expiration Date: OWS122
Approval Date: 01112117
Page 9 of 15
APPROVED ASSEMBLIES -- EASYMOP SBS:
Deck Type 1: Wood, Non -Insulated
Deck Description: Minimum 19/32" plywood, wood plank
System E(5): Anchor sheet mechanically fastened to deck, membrane adhered with hot asphalt or
approved adhesive.
Anchor/Rase Sheet: One or more plies of ASTM D226 Type II or ASTM D2626 with a minimum 4" wide side
lap and a minimum 8" wide end lap, mechanically fastened to deck
Fastening: Approved nails and tin caps 6" o.c. within lap and two equally spaced staggered rows 12"
o.c. in the field (forAnchorlBase sheet only).
Membrane: EasyMop SBS applied to Anchor/Base Sheet with hot asphalt or with approved adhesive as
specified in RAS 118, 119 or 120.
(See # 13 in Installation Requirements for back nailing)
Surfacing: Approved Roof Assemblies as specified below.
INSTALLATION REQUMMENTs — EASYMOP SBS:
1. Tarco EasyMop SBS shall be installed in strict compliance with applicable Buuflding Codes.
2. Observe and comply with roofing practices and guidelines as outlined by the National Roofing Contractors
Associations (NRCA) when installing EasyMop SBS.
3. Durres installation, comply with Occupational Safety and Health Administration (OSHA) safety standards; use
common sense measures and adequate safety precautions to prevent accidents.
4. EasyMop SBS shall be an acceptable underiayment for mechanically fastened roof file and adhered roof the
applications.
5. Re -hasten any loose decldng panels, and check for protruding nail heads prior to the application of EasyMop
SBS.
6. EasyMop SBS shall not be adhered directly over any pre-existing roof membrane.
7. All approved substrates are to be clean, dry and free of any loose debris or moisture prior to the application of
the EasyMop SBS. Refer to applicable building codes prior to installation to verify acceptable substrates.
8. Prime all metal collars, flashing, valleys, liner, drip edge and concrete deck substrate with ASTM D 41 primer.
9. Applicator may cut EasyMop SBS into sections for workability and allow to relax prior to applicationL
10. Place EasyMop SBS over metal drip edge in accordance with RAS 111.
11. Install the first course of EasyMop SBS parallel to the eave edge.
12. It is recommended that end laps be staggered a minimum of 18" from the preceding course.
13. EasyMop SBS shall be back nailed along the head lap. The nails shall be, 11 gauge 114" approved ring shank
type applied with it minimum of a 15/8" approved tin cap or approved capnail as required per the High Veto city
Hurricane Zone (HVHZ) section of the FBC, at a mij.mum rate of12" o.t. Thc, head lap of the preceding
layer of underlayment is to cover the area being ba Vk e�.. v
14. Flash vent pipes, stacks, chimneys and penetrations an cc�mplisnce wig RuufA6sembly current product
Control Notice of Acceptance and applicable Building Code,
15. Vertical strapping of EasyMop SBS membranes is, accep abler -
4 �
Mt14NfNt7MQE COUN'1"1r
NOA No.:16-1116.09
�FgcrnfnwpExpiration Date: 01125/22
Approval Date: 01/12/17
Page 10 of 1s
GWgBRAL IJMTAnONS — EASYMOP SBS:
1. Fire classification is not part of this acceptance; refer to a current Approved Roofing Materials Directory for Ste
ratings of this product.
2. This acceptance is for prepared roofing applications. Minimum deck requirements shall be in compliance with
applicable buuilding code.
3. Tarco EasyMop SBS shall not be installed when any form of moisture such as water, dew, ra* etc. is present
on the substrate.
4. Tarco EasyMop SBS are to be applied to a smooth, clean and dry surface, with the deck free $om irregularities.
5. Ensure roof has positive drainage prior to installation of Tarco EasyMop SBS.
6. Tarco EasyMop SBS shall not be applied over a pre-existing roof membrane or system.
7. Cate should be taken during the loading procedure to laeep foot traffic to a minimum and avoid dropping the
roof covering directly on the undetlayment.
8. All tiles shall be staged (two tiles perpendicular to slope, four tiles on top parallel to slope) as per
mamtfacturer's requirements, not to exceed 6-high, to the standard maxh urn roof pitch of 5 :12 for flat tiles
and 6 :12 for hugged tiles (See Tile Staging Method diagram below).
At roof slopes greater than the above limitations, the use ofloading battens or toe boards are required to load the
roof tile.
Tr7e Staging Method
U
Front View - Staged Tiles (Slope --•)
Side View - Staged Tiles (Slope j)
9. The manufacturer reserves the right to change the file staging method at any time as well as the number of tiles
stacked, not to exceed the preceding maximum number of tiles limitation.
10. Tarco EasyMop SBS shall not be lent exposed as a temporary roof for longer than 180 days after application.
The mam*chnr reserves the right to change product exposure period at any time; not to exceed the preceding
maximum time limitations.
11. Refer to prepared roofing system Product Control Notice of Acceptance for listed approval of Tarco
underlayments with specific prepared roofing products. Tarco EasyMop SBS may be used with any approved
roof coverings Notice of Acceptance listing Tarco EasyMop SBS or TAS 104 standard as a component part of
an assenibly in the Notice of Acceptance.
If Tarco EasyMop SBS or the TAS 104 standards are not listed, a request may be made to the Authority Having
Jurisdiction (AHJ) or the Miami -Dade County Product Conl*ol Dap:�t�nerrt&tiproval provided that
approptiate documentation is provided to detail cons a jk ljf of vW uplift resistance, and fire
tesd% results. V ,.
12. All products lised herein shall have a quality assurance audit in accordance with the Florida Building Code and
Rule 61 G20-3 of the Florida Administrative Code.
n"waoe cauN" NOA No.: 16-1116 09
Fapiradon Date: 0V25122
Approval Date: 0=117
Page 11 of 15
e • •
20. For ridge applications, center the underlayment and roll Som the center outward in both directions.
21. Flash vent pipes, stacks, chimneys and penetrations in compliance with RoofAssembly current Product
Control Notice ofAcceptance and applicable Building Code.
22. All protrusions or chains shall be initially taped with a 6" piece of like kdnd membrane. The flashing tape shall
be pressed in place and formed around the protrusion to ensure a tight fit. A second layer of like kind
membrane shall be applied over the flashing detail.
23. Vertical strapping of Tam self adhering membranes is acceptable.
GENERAL LIMITATIONS — TARco SELF-ADE=ED UNDERLAYMENTS:
1. Fire classification is not part of this acceptance; re&r to a current Approved Roofing Materials Directory for fire
ratings of this product.
2. This acceptance is for prepared roofing applications. Minimum deckregtrirements shall be in compliance with
applicable building code.
3. Tarco self adhering underlayments shall be applied only when material interface tempwatmes are 40OF and
rising.
4. Tatco self -adhered undalayments shall not be installed when any form of moisture such as water, dew, rain etc.
is present on the substrate.
S. Tarco self-adhand underiayments are to be applied to a smooth, clean and dry sur&ce, with the cock Sea Som
irregulatities.
6. Ensure roof has positive drainage prior to installation of Tarco self adhered undexlayme�ts
7. Tarco self -adhered shall not be applied over a pre-existing roof membrane or system.
8. ABerinstallation of Tarco self -adhered membranes, wait a minimum of 48 hours before roof loa ding of tiles.
9. Cate should be talon during the loading procedure to beep foot traffic to a ralaim un and avoid dropping the
roof covering directly on the underlayment.
10. All tiles shall be staged (two tiles perpendicular to slope, %ar tiles on top parallel to slope) as per
manufacturer's requirements, not to exceed 6-high, to the standard maximum roof pitch of 6 :12 for flat tiles
and 6 :12 for lugged tiles (See Tile Staging Method diagram below).
At roof slopes greater than the above limitations, the use of loading battens or toe boards ate req Bred to load the
roof tile.
Tile Staging Method
Front View - Staged Tides (Slope -+)
f
r
S%CC:-VJtG* - Staged Igo (Slope 1)
NOA No.: 16.1116.09
ERAratiion Date: OMSW
Approval Date: 01/12117
Page 14 of 15
11. The manufacturer reserves the right to change the tile staging method at any time as well as the mumber of tiles
stacked, not to exceed the preceding maximum number of tiles limitation.
12. EasyLay, PS200mu, MS300, SS400, and NR500m'shall not be left exposed as a temporary roof for longer than
30 days after application. PS20OR shall not be left exposed as a temporary roof for longer than 120 days after
application. Fast90 shall not be left exposed as a temporary roof for longer than 18 0 days after application. The
manufacturer reserves the right to change product exposure period at any time; not to exceed the preceding
maximum time limitations.
13. NR500ffTis not recommended for extreme high temperature emrironments such as under copper or zinc metal
roofing.
14. Refer to prepared roofing system Product Control Notice of Acceptance for listed approval of Tarco
underlayments with specific prepared roofing products. Tarco self -adhered underlayments may be used with
any approved roof coverings Notice of Acceptance listing Tarco self adhering underlayments or the ASTM
standard which the self adhering undetlayments meet as a component part of an assembly in the Notice of
Acceptance.
If Tarco selfadhered underlayments or the ASTM standards are not listed, a request may be made to the
Authority Having Jurisdiction (AHJ) or the Miami Dade County Product Control Department for approval
provided that appropriate documentation is provided to detail compatibility of the product, wind uplift
resistance, and fire testing results.
15. All products lised herein shall have a quality assurance audit in accordance with the Florida Building Code and
Rule 61 G20-3 of the Florida Administrative Code.
MANUFACTURER'S CONSIDERATIONS:
When using Fast90 and PS200M' in the roofing applications, use of loading battens or toe boards on roof slopes
greater than 6:12 and higher is recommended. When „s+ g EasyMop SBS in tale roofing applications, use of
loading battens or toe boards on roof slopes greater than 5:12 for Flat Tiles and 6:12 for Lugged Tiles and higher
is recommended.
2. Code body requirements supersede manufacturer's recommendations and installation guidelines.
BUILDING PERMIT REQUIREMENTS:
Application for building petmit shall be accompanied by copies of the following:
1. This Notice of Acceptance.
2. Any other documents required by the Building Official or applicable building code in order to properly evaluate
the installation of these materials.
LABELING:
All membranes or packaging shall bear the imprint or identifiable marking of the mamtfactu refs name or logo, city,
state and the following statement: "Nflami Dade County Product Control Approved" or the Miami Dade County
Product Control Seal as shown below.
END OF THIS, A,CC PTA- * "F.
HI M1taADe CCK*n-YM NOA No.: 16-1116.09
Fapiration Date: 01125M
Approval Date: 01112/17
Page 15 of is