Loading...
HomeMy WebLinkAboutAPPROVED 6.11.21 - 610355- Abrahams- Condition Assessment Letter 2435 NW Lakeridge 20210526-Sealed PBEEERYL To: St. Lucie County Building &Permitting Department From: Leo Cannyn, PMP, P.E., Principal Project Manager Subject: 2435 NW Lakeridge Dr,Palm City,F134990 Engineering Affidavit Date: 5/26/2021 To Whom This May Concern: Beryl Project Engineering, LLC (`Beryl") was retained by RoofClaim.Com with regards to an open permit located at 2435 NW Lakeridge Dr, Palm City, F134990. This permit issued will be to re-roof an existing building. Beryl performed a review of the permit file as found on the St. Lucie County website, along with EagleViews and measurements from site visits to the property. This review was a visual non- invasive review of the Roof and grounds. Beryl used the 2020 Florida Building Code as a guideline. The primary purpose of this letter is for Beryl as Engineer to certify that at the time of their review on 5/26/2021, that this letter serve as a site-specific plan indicating all retro openings and the required design pressures along with worst case design pressure chart for a building with a mean height of less than 30 feet. Beryl used a conservative 6:12 Roof Pitch (26.57 Degrees) with a rounded Mean Height of 20 Feet for their calculations shown below for Synthetic Underlayment with Asphalt Singles. The height from ground to eave was 10 feet and the height from ground to ridge was 23 feet for an exposure category of B. The VULT was assumed to be 165 based on Florida Residential Code Figure R301.2(3). 8202'%N Armenia Ave,Tampa, FI 33604 (813)616-3301 1 beryl engineering.com PBEEERNEE L TABLE R301.2(2) COMPONENT AND CLADDING LOADS FOR A BUILDING WITH A MEAN ROOF HEIGHT OF 30 FEET LOCATED IN EXPOSURE B (ASD)(psf)a,b,c,d,e,f EFFECTIVE ULTIMATE DESIGN WIND SPEED, VULr(mph) ZONE WIND AREA 160 170 (tt') Pos Neg Pos Neg 1.2e 10 20.6 -39.3 23.3 -44.4 1.2e 20 17.8 -39.3 20.1 -44.4 1.2e 50 14.0 -33.5 15.9 -37.8 1.2e 100 11.2 -28.8 12.7 -32.5 2n.2r.3e 10 20.6 -62.8 23.3 -70.8 2n.2r.3e 20 17.8 -55.0 20.1 -62.1 Gable Roof>20 to 27 degrees 2n 2r.3e 50 14.0 -44.7 15.9 -50.5 2n.2r.3e 100 112 -37.0 12.7 -41.8 3r 10 20.6 -74.5 23.3 -84.1 3r 20 178 -62.8 20.1 -70.8 3r 50 140 -46A 15.9 -52.3 3r 100 112 -46.4 12.7 -52.3 TABLE R301.2(3)HEIGHT AND EXPOSURE ADJUSTMENT COEFFICIENTS FOR TABLE R301.2(2) MEAN ROOF HEIGHT EXPOSURE CATEGDRY (ft) B C ❑ 15 0.82 1 1.21 1.47 20 0.89 11.29 1 99 a Wall Pressure Chart Gable Roof Uplift Chart I I 77 s s • � D 112 01 O Q ELEVATION Lj w PLAN 8202'/2 N Armenia Ave,Tampa, FI 33604 (813)616-3301 1 beryl engineering.com ','` BERYL * I * PROJECT ENGINEERING From, Digitally signed Thi.Rem has bean '!eeriri ,� '`MY' uleaa Mully. ned and y •��G�N��"pper� T'•. IMbvRlehamGmm� b Richard P.E.u.ina a Digital No.65884 Manalum and date.Primed * *:.pi.dthi.documam Cannyn not—Mdercd.ian.d �.and sealed and all <OR.—ION����`` ^^"a rc^"a•^^R^" Date: 2021 .05.26 pN*"'gt?,. on any eieanoma ao^le.. 10:28:32 -04'00' Richard Leon Cannyn Florida PE# 65994 5/26/2021 CC: Beryl Project Files This document has been electronically sealed in accordance with Florida Statute 471.025 and Florida Statute 668.001 -668.006. 8202'/z N Armenia Ave,Tampa, FI 33604 (813)616-3301 •berylengineering.com Premium Report '/ eagleview ­ 3/5/2021 2435 Northwest dg- Drive, Palm City, FL 34990 ' -p• 1 TABLE OF CONTENTS Images .....................................................................1 LengthDiagram.........................................................4 PitchDiagram............................................................5 AreaDiagram ............................................................6 NotesDiagram...........................................................7 Penetrations Diagram.................................................8 Report Summary........................................................9 MEASUREMENTS Total Roof Area =6,210 sq ft Total Roof Facets =22 Predominant Pitch =6/12 Number of Stories <=1 Total Ridges/Hips =213 ft Total Valleys =139 ft Total Rakes =264 ft Total Eaves =253 ft In this 3D model,facets appear as semi-transparent to reveal overhangs. Total Penetrations =8 Total Penetrations Perimeter = 25 ft Total Penetrations Area = 5 sq ft Claim: 610355 PREPARED FOR Contact: Daniel Plumlee Company: RoofClaim.com Address: 1690 Roberts Blvd, Ste 112 Kennesaw, GA 30144 Phone: 225-424-6852 Measurements provided by www.eagleview.com v Certified Accurate www.eagleview.com/Guarantee.aspx ©2008-2021 Eagle View Technologies,Inc.and Pictometry International Corp.—All Rights Reserved— Covered by one or more of U.S.Patent Nos.8,078,436;8,145,578;8,170,840;8,209,152;8,515,125;8,825,454;9,135,737;8,670,961; 9,514,568;8,818,770;8,542,880;9,244,589;9,329,749;9,599,466.Other Patents Pending. Premium Report 3/5/2021 Claim: 610355 Northwest2435 ••- Drive, Palm City, FL 34990 ' -•• 1 IMAGES The following aerial images show different angles of this structure for your reference. Top View c ,M "Will,C11 t 4 , R 1 � - r k', . r - 14 4 �7 k ©2008-2021 Eagle View Technologies,Inc.and Pictometry International Corp.—All Rights Reserved— Covered by one or more of U.S.Patent Nos.8,078,436;8,145,578;8,170,840;8,209,152;8,515,125;8,825,454;9,135,737;8,670,961; 9,514,568;8,818,770;8,542,880;9,244,589;9,329,749;9,599,466.Other Patents Pending. PAGE 1 Premium ReportppIQvipV 3/5/2021 Claim: 610355 Northwest2435 ••- Drive, Palm City, FL 34990 ' -•• 1 IMAGES North Side ilk r r r South Side r 6 • _ 1V1012019 ©2008-2021 Eagle View Technologies,Inc.and Pictometry International Corp.—All Rights Reserved— Covered by one or more of U.S.Patent Nos.8,078,436;8,145,578;8,170,840;8,209,152;8,515,125;8,825,454;9,135,737;8,670,961; 9,514,568;8,818,770;8,542,880;9,244,589;9,329,749;9,599,466.Other Patents Pending. PAGE 2 Premium ReportpU IQviQW 3/5/2021 Claim: 610355 Northwest2435 ••- Drive, Palm City, FL 34990 ' -•• 1 IMAGES East Side J� I West Side 4 ©2008-2021 Eagle View Technologies,Inc.and Pictometry International Corp.—All Rights Reserved— Covered by one or more of U.S.Patent Nos.8,078,436;8,145,578;8,170,840;8,209,152;8,515,125;8,825,454;9,135,737;8,670,961; 9,514,568;8,818,770;8,542,880;9,244,589;9,329,749;9,599,466.Other Patents Pending. PAGE 3 Report eagleview TM Premium 3/5/2021 Claim: 610355 2435 Northwest Lakeridge Drive, Palm City, FL 34990 Report: 38745501 LENGTH DIAGRAM Total Line Lengths: Valleys = 139 ft Flashing = 25 ft Ridges = 197 ft Rakes = 264 ft Step flashing = 75 ft Hips = 16 ft Eaves = 253 ft Parapets = 0 ft 17— L-1-9------------------9-111 ;2 151 L----+6 115 O ii 19 11 11�2 0 //6 00 71 38 co N VY E 19 S Note: This diagram contains segment lengths(rounded to the nearest whole number)over 5.0 Feet. In some cases, segment labels have been removed for readability. Plus signs preface some numbers to avoid confusion when rotated (e.q. +6 and +9). @ 2008-2021 Eagle View Technologies,Inc.and Pictometry International Corp.—All Rights Reserved— Covered by one or more of U.S.Patent Nos.8,078,436;8,145,578;8,170,840;8,209,152;8,515,125;8,825,454;9,135,737;8,670,961; 9,514,568;8,818,770;8,542,880;9,244,589;9,329,749;9,599,466.Other Patents Pending. PAGE 4 Premium ReportppIQviQY - 3/5/2021 Claim: 610355 Northwest2435 ••- Drive, Palm City, FL 34990 ' —•• 1 PITCH DIAGRAM Pitch values are shown in inches per foot, and arrows indicate slope direction. The predominant pitch on this roof is 6/12 +6 +6 +6 +6 F+6 +6 +6 F+6 N T +6 `+° 6 e (0 1 F+6 +6 ' NN W 1 E S Note: This diagram contains labeled pitches for facet areas larger than 20.0 square feet. In some cases, pitch labels have been removed for readability. Blue shading indicates a pitch of 3/12 and greater. Gray shading indicates flat, 1/12 or 2/12 pitches. ©2008-2021 Eagle View Technologies,Inc.and Pictometry International Corp.—All Rights Reserved— Covered by one or more of U.S.Patent Nos.8,078,436;8,145,578;8,170,840;8,209,152;8,515,125;8,825,454;9,135,737;8,670,961; 9,514,568;8,818,770;8,542,880;9,244,589;9,329,749;9,599,466.Other Patents Pending. PAGE 5 Premium Report eIeVIQw - 3/5/2021 Claim: 610355 AREA DIAGRAM Total Area = 6,210 sq ft, with 22 facets. 132 42 331 342 367 173 121 121+ a� 2 1658 a 8 4 8 a w 1760 533 535 TN W E S Note: This diagram shows the square feet of each roof facet(rounded to the nearest Foot). The total area in square feet, at the top of this page, is based on the non-rounded values of each roof facet(rounded to the nearest square foot after being totaled). ©2008-2021 Eagle View Technologies,Inc.and Pictometry International Corp.—All Rights Reserved— Covered by one or more of U.S.Patent Nos.8,078,436;8,145,578;8,170,840;8,209,152;8,515,125;8,825,454;9,135,737;8,670,961; 9,514,568;8,818,770;8,542,880;9,244,589;9,329,749;9,599,466.Other Patents Pending. PAGE 6 TM Premium Report e I e V I 4Q 3/5/2021 Claim: 610355 Northwest2435 ••- Drive, Palm City, FL 34990 ' -•• 1 NOTES DIAGRAM Roof facets are labeled from smallest to largest(A to Z)for easy reference. N P O R O M L E a� U a a w V S T TN W E S ©2008-2021 Eagle View Technologies,Inc.and Pictometry International Corp.—All Rights Reserved— Covered by one or more of U.S.Patent Nos.8,078,436;8,145,578;8,170,840;8,209,152;8,515,125;8,825,454;9,135,737;8,670,961; 9,514,568;8,818,770;8,542,880;9,244,589;9,329,749;9,599,466.Other Patents Pending. PAGE 7 Premium Report - e U I G v I 0 Y Y M 3/5/2021 Claim: 610355 Northwest2435 ••- Drive, Palm City, FL 34990 ' —•• 1 PENETRATIONS NOTES DIAGRAM Penetrations are labeled from smallest to largest for easy reference. Total Penetrations = 8 Total Penetrations Area = 5 sq ft Total Penetrations Perimeter = 25 ft Total Roof Area Less Penetrations = 6,205 sq ft 50 2 4❑ 3❑ 7❑ 8❑ N A IN E S ©2008-2021 Eagle View Technologies,Inc.and Pictometry International Corp.—All Rights Reserved— Covered by one or more of U.S.Patent Nos.8,078,436;8,145,578;8,170,840;8,209,152;8,515,125;8,825,454;9,135,737;8,670,961; 9,514,568;8,818,770;8,542,880;9,244,589;9,329,749;9,599,466.Other Patents Pending. PAGE 8 Premium Report eIQ IQw 3/5/2021 Claim: 610355 Northwest2435 ••- 4991 ' -•• 1 REPORT SUMMARY All Structures Areas per Pitch _Roof Pitches 2/12 6/12 8/12 Area (sq ft) 8.6 6184.3 16.4 of Roof 0.1% 99.6% 0.3% The table above lists each pitch on this roof and the total area and percent(both rounded) of the roof with that pitch. Structure Complexity Simple Normal Complex NOTE:Waste Calculation asphalt .. roof areas of 3/12 pitch or gre sectionLor total measurements of all pitches,please refer to the Lengths,Areas,and Pitches below. Waste % 00/0 4% 7% 90/0 11% 14% 19% 24% 29% Area (Sq ft) 6201 6450 6636 6760 6884 7070 7380 7690 8000 Squares* 62.33 64.66 66.66 67.66 69.00 71.00 74.00 77.00 80.00 Measured Suggested * Squares are rounded up to the 1/3 of a square Additional materials needed for ridge, hip, and starter lengths are not included in the above table. The provided suggested waste factor is intended to serve as a guide—actual waste percentages may differ based upon several variables that EagleView does not control. These waste factor variables include, but are not limited to, individual installation techniques, crew experiences, asphalt shingle material subtleties, and potential salvage from the site. Individual results may vary from the suggested waste factor that EagleView has provided. The suggested waste is not to replace or substitute for experience or judgment as to any given replacement or repair work. Penetrations 1-6 7-8 Area (sq ft) 1 0.5 1 Perimeter(ft) 1 2.8 4 Any measured penetration smaller than 3.Ox3.0 Feet may need field verification. Accuracy is not guaranteed. The total penetration area is not subtracted from the total roof area. ©2008-2021 Eagle View Technologies,Inc.and Pictometry International Corp.—All Rights Reserved— Covered by one or more of U.S.Patent Nos.8,078,436;8,145,578;8,170,840;8,209,152;8,515,125;8,825,454;9,135,737;8,670,961; 9,514,568;8,818,770;8,542,880;9,244,589;9,329,749;9,599,466.Other Patents Pending. PAGE 9 levie W TKI Premium Report ■ 3/5/2021 M Claim: 610355 2435 Northwest Lakeridge Drive, Palm City, FL 34990 Report: 38745501 All Structures Totals Lengths,Areas and Pitches Property Location Ridges = 197 ft(8 Ridges) Longitude = -80,3013109 Hips = 16 ft(4 Hips). Latitude = 27.2251337 Valleys = 139 ft(9 Valleys) Notes Rakes' = 264 ft(22 Rakes) This was ordered as a residential Eaves/Starter# = 253 ft(22 Eaves) property. There were no changes to Drip Edge (Eaves + Rakes) = 517 ft(44 Lengths) the structure in the past four years. Parapet Walls = 0 (0 Lengths). Flashing = 25 ft(7 Lengths) Step flashing = 75 ft(15 Lengths) Total Penetrations Area = 5 sq ft Total Roof Facets = 22 Total Roof Area Less Penetrations = 6,205 sq ft Total Penetrations =8 Total Penetrations Perimeter = 25 ft Predominant Pitch = 6/12 Total Area (All Pitches) = 6,210 sq ft Online Maps Online map of property htti)://mai)s.google.com/maps?f=q&source=s g&hI=en&geocode=&q=2435+Northwest+Lakeridge+Drive,Palm+City,FL,34990 Directions from RoofClaim.com to this property http://maps.google.com/maps?f=d&source=s d&saddr=1690+Roberts+Blvd,+Ste+112,Ken nesaw,GA,30144&dadd r=243 5+Northwest +Lakeridge+Drive,Palm+City,FL,34990 t Rakes are defined as roof edges that are sloped(not level). t Eaves are defined as roof edges that are not sloped and level. ©2008-2021 Eagle View Technologies,Inc.and Pictometry International Corp.—All Rights Reserved— Covered by one or more of U.S.Patent Nos.8,078,436;8,145,578;8,170,840;8,209,152;8,515,125;8,825,454;9,135,737;8,670,961; 9,514,568;8,818,770;8,542,880;9,244,589;9,329,749;9,599,466.Other Patents Pending. PAGE 10