Loading...
HomeMy WebLinkAboutfire departmentSAINT LUCIE COUNTY FIRE DISTRICT PLAN REVIEW FORM 5160 N.W. Milner Drive Port Saint Lucie, FL 34983 Telephone: 772-621-3322 Fax: 772-621-3604 Web Address: wrww.slcfd.com SLC - -- _—+ - — — --- FMO Permit # IB21 207 —'— ArP Cabinets & Granite -- --- --� I BLDG Permit # I2104-0311 i601r— — ----^ �" --� Pdort.", 39th Street Bela 'Vista Contractors r--- 750 East Sample Road City FL —.--- - ---� Zip City Ft Pierce IPompano Beach 133064 I Telephone 1(954) 644-3121 Architect/Engineer Architectonics in: --_— - -- -- Telephone (772) 460-7751 1 — --- Construction Type `VB — Square Feet 3620 I5 Pe plans J Dumber of Stories 'i _ Access 8-,,x J Access Key Switch FA Permit FFPPermit Required General Notes 1. An electronic copy of the construction documents submitted on a CD is required. Tkke f;ice format shall be .pdf only. 2. All revisions, including the electronic copy must be received prior to permitting. 3. The Fire Marshal requires 24 hour notice on all inspections. 4. A Radio coverage Pre -Survey Signal Strength inspection is required before any final inspection is scheduled. 5. The respective Building Department shall schedule all final inspections LhroLah the Fire Marshal's Office. 6. Failed inspections require payment of fee prior to rescheduling of further ;nspections. 7. Penetrations through rated assemblies shall be of the proper UL design:. Design criteria shall be submitted with the construction plans. 8. Fire alarm paceis shall be located indoors within air conditioned space. 9. Plans and construction are subject to corrections in the field to maintain code compliance. 10. Automatic fan shutdown is required for PVAC system/s that exceed 2,000 cfm design capacity. 11. The Installation or Alteration of Fire Sprinklers, Fire Alarms, and Fixed Fire Protection. Systems require a separate review and permit. THE CURRENTLY ADOPTED VERSION OF THE FLORIDA FIRE PREVENTION CODE IS ENFORCED. BUILDINGS WITH LIGHT -FRAME TRUSS -TYPE CONSTRUCTION SHALL BE MARKED WITH APPROVED FIREFIGHTER SAFETY 1RNING SIGNS IN ACCORDANCE WITH FLORIDA ADMINISTRATIVE CODES 69A-3.012 AND 69A-60.0081 PRIOR TO RECEIVING A CERTIFICATE OF OCCUPANCY. Sze General Notes Above and Required Revisions Below 1. Automatic fan shutdown is required for HVAC system/s that exceed 2.,000 cfm design capacity. Provide a remote test and inspect appliance equipped with an audible/visual indicator for each HVAC riuct smoke detector 2.The stove in the kitchen Shall be prDtected with an U.L. approved Fire Suppression System. 3. The Installation or Aiteration of a Fixed Fire Prct�-ction System require a separate review and permit. Date 06-03-2021 Reviewed by Tony Jerger j