Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
APPROVED WS 24 - Truss Package
6904 Parke East Blvd. Tampa, FL 33610-4115 MiTek USA, Inc. RE: WS0024 - Design Code: FBC2020/TPI2014 Wind Code: N/A Wind Speed: 165 mph Roof Load: 37.0 psf Design Program: MiTek 20/20 8.4 1 of 2 This package includes 33 individual, Truss Design Drawings and 0 Additional Drawings. With my seal affixed to this sheet, I hereby certify that I am the Truss Design Engineer and this index sheet conforms to 61G15-31.003, section 5 of the Florida Board of Professional Engineers Rules. General Truss Engineering Criteria & Design Loads (Individual Truss Design Drawings Show Special Loading Conditions): Floor Load: N/A psf Site Information: Lot/Block: 24 Customer Info: K Hovnanian Homes Project Name: WS0024 Model: Lelia-A Subdivision: Waterstone Address: 5130 Armina Place, . State: FLCity: Fort Pierce Name Address and License # of Structural Engineer of Record, If there is one, for the building. Name: License #: Address: City: State: April 9,2021 Velez, Joaquin The truss drawing(s) referenced above have been prepared by MiTek USA, Inc. under my direct supervision based on the parameters provided by Builders FirstSource - Plant City. Truss Design Engineer's Name: Velez, Joaquin My license renewal date for the state of Florida is February 28, 2023. Lumber design values are in accordance with ANSI/TPI 1 section 6.3 These truss designs rely on lumber values established by others. IMPORTANT NOTE: The seal on these truss component designs is a certification that the engineer named is licensed in the jurisdiction(s) identified and that the designs comply with ANSI/TPI 1. These designs are based upon parameters shown (e.g., loads, supports, dimensions, shapes and design codes), which were given to MiTek or TRENCO. Any project specific information included is for MiTek's or TRENCO's customers file reference purpose only, and was not taken into account in the preparation of these designs. MiTek or TRENCO has not independently verified the applicability of the design parameters or the designs for any particular building. Before use, the building designer should verify applicability of design parameters and properly incorporate these designs into the overall building design per ANSI/TPI 1, Chapter 2. No.Seal#Truss Name 1 T23501810 CJ1 Date 4/9/212T23501811CJ34/9/213T23501812CJ3A4/9/214T23501813CJ54/9/215T23501814CJ5A4/9/216T23501815EJ74/9/217T23501816HJ54/9/218T23501817HJ74/9/219T23501818T014/9/2110T23501819T024/9/2111T23501820T034/9/2112T23501821T044/9/2113T23501822T054/9/2114T23501823T064/9/21 No.Seal#Truss Name 15 T23501824 T07 Date 4/9/2116T23501825T084/9/2117T23501826T094/9/2118T23501827T104/9/2119T23501828T114/9/2120T23501829T124/9/2121T23501830T134/9/2122T23501831T144/9/2123T23501832T14A4/9/2124T23501833T154/9/2125T23501834T164/9/2126T23501835T174/9/2127T23501836T184/9/2128T23501837T194/9/21 This item has been electronically signed and sealed by Velez, Joaquin, PE using a Digital Signature. Printed copies of this document are not considered signed and sealed and the signature must be verified on any electronic copies 6904 Parke East Blvd. Tampa, FL 33610-4115 MiTek USA, Inc. RE: WS0024 - 2 of 2 Site Information: Lot/Block: 24 Customer Info: K Hovnanian Homes Project Name: WS0024 Model: Lelia-A Subdivision: Waterstone Address: 5130 Armina Place, . State: FLCity: Fort Pierce No.Seal#Truss Name 29 T23501838 T20 Date 4/9/2130T23501839V014/9/2131T23501840V024/9/2132T23501841V034/9/2133T23501842V044/9/21 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component available from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 5/19/2020 BEFORE USE. 6904 Parke East Blvd. Tampa, FL 36610 Job WS0024 Truss CJ1 Truss Type CORNER JACK Qty 12 Ply 1 Job Reference (optional) T23501810 8.430 s Mar 22 2021 MiTek Industries, Inc. Thu Apr 8 08:14:40 2021 Page 1 Builders FirstSource (Tampa, FL), Tampa, FL - 33564, ID:JbsSUYEphcZuYTshvwE3BRyhOBX-buuQ?2yvlf7EusLrFJq_URjzDHTsxkN5ekcmdKzSqyz Scale = 1:6.5 1 2 3 4 2x4 ST1.5x8 STP 1-0-0 1-0-0 -1-0-0 1-0-0 1-0-0 1-0-0 0-4-10-9-10-4-100-9-15.00 12 Plate Offsets (X,Y)-- [2:0-1-14,0-0-10] LOADING (psf) TCLL TCDL BCLL BCDL 20.0 7.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.25 1.25 YES FBC2020/TPI2014 CSI. TC BC WB Matrix-P 0.15 0.01 0.00 DEFL. Vert(LL) Vert(CT) Horz(CT) in -0.00 -0.00 -0.00 (loc) 2 2 3 l/defl >999 >999 n/a L/d 240 180 n/a PLATES MT20 Weight: 5 lb FT = 20% GRIP 244/190 LUMBER- TOP CHORD 2x4 SP No.3 BOT CHORD 2x4 SP No.3 BRACING- TOP CHORD Structural wood sheathing directly applied or 1-0-0 oc purlins. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS. (size)3=Mechanical, 2=0-8-0, 4=Mechanical Max Horz 2=40(LC 12) Max Uplift 3=-8(LC 1), 2=-97(LC 12) Max Grav 3=18(LC 12), 2=125(LC 1), 4=18(LC 3) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. NOTES-(7) 1) Wind: ASCE 7-16; Vult=165mph (3-second gust) Vasd=128mph; TCDL=4.2psf; BCDL=3.0psf; h=15ft; B=45ft; L=28ft; eave=4ft; Cat. II; Exp B; Encl., GCpi=0.18; MWFRS (directional) and C-C Exterior(2E) zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 2) Building Designer / Project engineer responsible for verifying applied roof live load shown covers rain loading requirements specific to the use of this truss component. 3) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 4) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 5) Refer to girder(s) for truss to truss connections. 6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 8 lb uplift at joint 3 and 97 lb uplift at joint 2. 7) "This manufactured product is designed as an individual building component. The suitability and use of this component for any particular building is the responsibility of the building designer per ANSI TPI 1 as referenced by the building code."This item has been electronically signed and sealed by Velez, Joaquin, PE using a Digital Signature. Printed copies of this document are not considered signed and sealed and the signature must be verified on any electronic copies. April 9,2021 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component available from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 5/19/2020 BEFORE USE. 6904 Parke East Blvd. Tampa, FL 36610 Job WS0024 Truss CJ3 Truss Type Corner Jack Qty 11 Ply 1 Job Reference (optional) T23501811 8.430 s Mar 22 2021 MiTek Industries, Inc. Thu Apr 8 08:14:40 2021 Page 1 Builders FirstSource (Tampa, FL), Tampa, FL - 33564, ID:JbsSUYEphcZuYTshvwE3BRyhOBX-buuQ?2yvlf7EusLrFJq_URjy0HR4xkN5ekcmdKzSqyz Scale = 1:10.8 1 2 5 3 4 2x4 ST1.5x8 STP 3-0-0 3-0-0 -1-0-0 1-0-0 3-0-0 3-0-0 0-4-11-7-11-2-101-7-15.00 12 Plate Offsets (X,Y)-- [2:0-1-14,0-0-10] LOADING (psf) TCLL TCDL BCLL BCDL 20.0 7.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.25 1.25 YES FBC2020/TPI2014 CSI. TC BC WB Matrix-P 0.23 0.13 0.00 DEFL. Vert(LL) Vert(CT) Horz(CT) in -0.00 -0.01 -0.00 (loc) 2-4 2-4 3 l/defl >999 >999 n/a L/d 240 180 n/a PLATES MT20 Weight: 11 lb FT = 20% GRIP 244/190 LUMBER- TOP CHORD 2x4 SP No.3 BOT CHORD 2x4 SP No.3 BRACING- TOP CHORD Structural wood sheathing directly applied or 3-0-0 oc purlins. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS. (size)3=Mechanical, 2=0-8-0, 4=Mechanical Max Horz 2=71(LC 12) Max Uplift 3=-32(LC 12), 2=-106(LC 12) Max Grav 3=54(LC 17), 2=187(LC 1), 4=52(LC 3) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. NOTES-(7) 1) Wind: ASCE 7-16; Vult=165mph (3-second gust) Vasd=128mph; TCDL=4.2psf; BCDL=3.0psf; h=15ft; B=45ft; L=28ft; eave=4ft; Cat. II; Exp B; Encl., GCpi=0.18; MWFRS (directional) and C-C Exterior(2E) -1-0-0 to 2-0-0, Interior(1) 2-0-0 to 2-11-4 zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 2) Building Designer / Project engineer responsible for verifying applied roof live load shown covers rain loading requirements specific to the use of this truss component. 3) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 4) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 5) Refer to girder(s) for truss to truss connections. 6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 32 lb uplift at joint 3 and 106 lb uplift at joint 2. 7) "This manufactured product is designed as an individual building component. The suitability and use of this component for any particular building is the responsibility of the building designer per ANSI TPI 1 as referenced by the building code."This item has been electronically signed and sealed by Velez, Joaquin, PE using a Digital Signature. Printed copies of this document are not considered signed and sealed and the signature must be verified on any electronic copies. April 9,2021 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component available from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 5/19/2020 BEFORE USE. 6904 Parke East Blvd. Tampa, FL 36610 Job WS0024 Truss CJ3A Truss Type Corner Jack Qty 1 Ply 1 Job Reference (optional) T23501812 8.430 s Mar 22 2021 MiTek Industries, Inc. Thu Apr 8 08:14:41 2021 Page 1 Builders FirstSource (Tampa, FL), Tampa, FL - 33564, ID:JbsSUYEphcZuYTshvwE3BRyhOBX-44SoDOzXWzF5W0v2p0LD1fG6mhnrgBdEtOLK9mzSqyy Scale = 1:10.8 1 2 3 2x4 3-0-0 3-0-0 3-0-0 3-0-0 0-4-11-7-11-2-101-7-15.00 12 Plate Offsets (X,Y)-- [1:0-0-2,Edge] LOADING (psf) TCLL TCDL BCLL BCDL 20.0 7.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.25 1.25 YES FBC2020/TPI2014 CSI. TC BC WB Matrix-P 0.30 0.16 0.00 DEFL. Vert(LL) Vert(CT) Horz(CT) in -0.00 -0.01 -0.00 (loc) 1-3 1-3 2 l/defl >999 >999 n/a L/d 240 180 n/a PLATES MT20 Weight: 9 lb FT = 20% GRIP 244/190 LUMBER- TOP CHORD 2x4 SP No.3 BOT CHORD 2x4 SP No.3 BRACING- TOP CHORD Structural wood sheathing directly applied or 3-0-0 oc purlins. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS. (size)1=Mechanical, 2=Mechanical, 3=Mechanical Max Horz 1=49(LC 12) Max Uplift 1=-24(LC 12), 2=-54(LC 12) Max Grav 1=106(LC 1), 2=78(LC 1), 3=58(LC 3) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. NOTES-(7) 1) Wind: ASCE 7-16; Vult=165mph (3-second gust) Vasd=128mph; TCDL=4.2psf; BCDL=3.0psf; h=15ft; B=45ft; L=28ft; eave=4ft; Cat. II; Exp B; Encl., GCpi=0.18; MWFRS (directional) and C-C Exterior(2E) zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 2) Building Designer / Project engineer responsible for verifying applied roof live load shown covers rain loading requirements specific to the use of this truss component. 3) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 4) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 5) Refer to girder(s) for truss to truss connections. 6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 24 lb uplift at joint 1 and 54 lb uplift at joint 2. 7) "This manufactured product is designed as an individual building component. The suitability and use of this component for any particular building is the responsibility of the building designer per ANSI TPI 1 as referenced by the building code."This item has been electronically signed and sealed by Velez, Joaquin, PE using a Digital Signature. Printed copies of this document are not considered signed and sealed and the signature must be verified on any electronic copies. April 9,2021 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component available from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 5/19/2020 BEFORE USE. 6904 Parke East Blvd. Tampa, FL 36610 Job WS0024 Truss CJ5 Truss Type Corner Jack Qty 9 Ply 1 Job Reference (optional) T23501813 8.430 s Mar 22 2021 MiTek Industries, Inc. Thu Apr 8 08:14:41 2021 Page 1 Builders FirstSource (Tampa, FL), Tampa, FL - 33564, ID:JbsSUYEphcZuYTshvwE3BRyhOBX-44SoDOzXWzF5W0v2p0LD1fG3MhlFgBdEtOLK9mzSqyy Scale = 1:15.8 1 2 5 6 3 4 2x4 ST1.5x8 STP 5-0-0 5-0-0 -1-0-0 1-0-0 5-0-0 5-0-0 0-4-12-5-12-0-102-5-15.00 12 Plate Offsets (X,Y)-- [2:0-1-14,0-0-10] LOADING (psf) TCLL TCDL BCLL BCDL 20.0 7.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.25 1.25 YES FBC2020/TPI2014 CSI. TC BC WB Matrix-P 0.45 0.26 0.00 DEFL. Vert(LL) Vert(CT) Horz(CT) in -0.03 -0.05 -0.00 (loc) 2-4 2-4 3 l/defl >999 >999 n/a L/d 240 180 n/a PLATES MT20 Weight: 17 lb FT = 20% GRIP 244/190 LUMBER- TOP CHORD 2x4 SP No.2 BOT CHORD 2x4 SP No.2 BRACING- TOP CHORD Structural wood sheathing directly applied or 5-0-0 oc purlins. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS. (size)3=Mechanical, 2=0-8-0, 4=Mechanical Max Horz 2=103(LC 12) Max Uplift 3=-77(LC 12), 2=-116(LC 12) Max Grav 3=114(LC 17), 2=253(LC 1), 4=92(LC 3) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. NOTES-(7) 1) Wind: ASCE 7-16; Vult=165mph (3-second gust) Vasd=128mph; TCDL=4.2psf; BCDL=3.0psf; h=15ft; B=45ft; L=28ft; eave=4ft; Cat. II; Exp B; Encl., GCpi=0.18; MWFRS (directional) and C-C Exterior(2E) -1-0-0 to 2-0-0, Interior(1) 2-0-0 to 4-11-4 zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 2) Building Designer / Project engineer responsible for verifying applied roof live load shown covers rain loading requirements specific to the use of this truss component. 3) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 4) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 5) Refer to girder(s) for truss to truss connections. 6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 77 lb uplift at joint 3 and 116 lb uplift at joint 2. 7) "This manufactured product is designed as an individual building component. The suitability and use of this component for any particular building is the responsibility of the building designer per ANSI TPI 1 as referenced by the building code."This item has been electronically signed and sealed by Velez, Joaquin, PE using a Digital Signature. Printed copies of this document are not considered signed and sealed and the signature must be verified on any electronic copies. April 9,2021 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component available from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 5/19/2020 BEFORE USE. 6904 Parke East Blvd. Tampa, FL 36610 Job WS0024 Truss CJ5A Truss Type Corner Jack Qty 1 Ply 1 Job Reference (optional) T23501814 8.430 s Mar 22 2021 MiTek Industries, Inc. Thu Apr 8 08:14:42 2021 Page 1 Builders FirstSource (Tampa, FL), Tampa, FL - 33564, ID:JbsSUYEphcZuYTshvwE3BRyhOBX-YH0AQk_AHGNy7AUENksSZsoCe54yPesO625thDzSqyx Scale = 1:14.9 1 4 5 2 3 2x4 5-0-0 5-0-0 5-0-0 5-0-0 0-4-12-5-12-0-102-5-15.00 12 Plate Offsets (X,Y)-- [1:0-0-2,Edge] LOADING (psf) TCLL TCDL BCLL BCDL 20.0 7.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.25 1.25 YES FBC2020/TPI2014 CSI. TC BC WB Matrix-P 0.54 0.29 0.00 DEFL. Vert(LL) Vert(CT) Horz(CT) in -0.03 -0.07 -0.00 (loc) 1-3 1-3 2 l/defl >999 >863 n/a L/d 240 180 n/a PLATES MT20 Weight: 16 lb FT = 20% GRIP 244/190 LUMBER- TOP CHORD 2x4 SP No.2 BOT CHORD 2x4 SP No.2 BRACING- TOP CHORD Structural wood sheathing directly applied or 5-0-0 oc purlins. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS. (size)1=Mechanical, 2=Mechanical, 3=Mechanical Max Horz 1=81(LC 12) Max Uplift 1=-42(LC 12), 2=-91(LC 12) Max Grav 1=180(LC 1), 2=132(LC 1), 3=98(LC 3) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. NOTES-(7) 1) Wind: ASCE 7-16; Vult=165mph (3-second gust) Vasd=128mph; TCDL=4.2psf; BCDL=3.0psf; h=15ft; B=45ft; L=28ft; eave=4ft; Cat. II; Exp B; Encl., GCpi=0.18; MWFRS (directional) and C-C Exterior(2E) 0-0-12 to 3-0-12, Interior(1) 3-0-12 to 4-11-4 zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 2) Building Designer / Project engineer responsible for verifying applied roof live load shown covers rain loading requirements specific to the use of this truss component. 3) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 4) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 5) Refer to girder(s) for truss to truss connections. 6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 42 lb uplift at joint 1 and 91 lb uplift at joint 2. 7) "This manufactured product is designed as an individual building component. The suitability and use of this component for any particular building is the responsibility of the building designer per ANSI TPI 1 as referenced by the building code."This item has been electronically signed and sealed by Velez, Joaquin, PE using a Digital Signature. Printed copies of this document are not considered signed and sealed and the signature must be verified on any electronic copies. April 9,2021 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component available from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 5/19/2020 BEFORE USE. 6904 Parke East Blvd. Tampa, FL 36610 Job WS0024 Truss EJ7 Truss Type Jack-Open Qty 19 Ply 1 Job Reference (optional) T23501815 8.430 s Mar 22 2021 MiTek Industries, Inc. Thu Apr 8 08:14:43 2021 Page 1 Builders FirstSource (Tampa, FL), Tampa, FL - 33564, ID:JbsSUYEphcZuYTshvwE3BRyhOBX-0TaZd4_o2aVplK3QwRNh64LLMVNH756XLiqQEfzSqyw Scale = 1:19.8 1 2 5 6 3 43x4 ST1.5x8 STP 7-0-0 7-0-0 -1-0-0 1-0-0 7-0-0 7-0-0 0-4-13-3-12-10-103-3-15.00 12 Plate Offsets (X,Y)-- [2:0-0-10,Edge] LOADING (psf) TCLL TCDL BCLL BCDL 20.0 7.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.25 1.25 YES FBC2020/TPI2014 CSI. TC BC WB Matrix-SH 0.67 0.48 0.00 DEFL. Vert(LL) Vert(CT) Horz(CT) in 0.10 -0.18 -0.00 (loc) 2-4 2-4 3 l/defl >773 >431 n/a L/d 240 180 n/a PLATES MT20 Weight: 23 lb FT = 20% GRIP 244/190 LUMBER- TOP CHORD 2x4 SP No.2 BOT CHORD 2x4 SP No.2 BRACING- TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS. (size)3=Mechanical, 2=0-8-0, 4=Mechanical Max Horz 2=136(LC 12) Max Uplift 3=-103(LC 12), 2=-130(LC 12) Max Grav 3=159(LC 1), 2=324(LC 1), 4=121(LC 3) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. NOTES-(7) 1) Wind: ASCE 7-16; Vult=165mph (3-second gust) Vasd=128mph; TCDL=4.2psf; BCDL=3.0psf; h=15ft; B=45ft; L=28ft; eave=4ft; Cat. II; Exp B; Encl., GCpi=0.18; MWFRS (directional) and C-C Exterior(2E) -1-0-0 to 2-0-0, Interior(1) 2-0-0 to 6-11-4 zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 2) Building Designer / Project engineer responsible for verifying applied roof live load shown covers rain loading requirements specific to the use of this truss component. 3) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 4) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 5) Refer to girder(s) for truss to truss connections. 6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 103 lb uplift at joint 3 and 130 lb uplift at joint 2. 7) "This manufactured product is designed as an individual building component. The suitability and use of this component for any particular building is the responsibility of the building designer per ANSI TPI 1 as referenced by the building code."This item has been electronically signed and sealed by Velez, Joaquin, PE using a Digital Signature. Printed copies of this document are not considered signed and sealed and the signature must be verified on any electronic copies. April 9,2021 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component available from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 5/19/2020 BEFORE USE. 6904 Parke East Blvd. Tampa, FL 36610 Job WS0024 Truss HJ5 Truss Type Roof Special Girder Qty 1 Ply 1 Job Reference (optional) T23501816 8.430 s Mar 22 2021 MiTek Industries, Inc. Thu Apr 8 08:14:43 2021 Page 1 Builders FirstSource (Tampa, FL), Tampa, FL - 33564, ID:JbsSUYEphcZuYTshvwE3BRyhOBX-0TaZd4_o2aVplK3QwRNh64LLQVMe75dXLiqQEfzSqyw Scale = 1:16.4 1 2 3 4 6 5 7 8 9 10 3x4 2x4 2x4 6-9-6 6-9-6 7-0-14 0-3-8 -1-5-0 1-5-0 6-9-6 6-9-6 7-0-14 0-3-8 0-3-132-4-133.54 12 LOADING (psf) TCLL TCDL BCLL BCDL 20.0 7.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.25 1.25 NO FBC2020/TPI2014 CSI. TC BC WB Matrix-SH 0.67 0.52 0.03 DEFL. Vert(LL) Vert(CT) Horz(CT) in -0.09 -0.19 0.00 (loc) 2-6 2-6 l/defl >910 >438 n/a L/d 240 180 n/a PLATES MT20 Weight: 26 lb FT = 20% GRIP 244/190 LUMBER- TOP CHORD 2x4 SP No.2 BOT CHORD 2x4 SP No.2 WEBS 2x4 SP No.3 BRACING- TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS. (size)2=1-5-0, 6=0-5-5 Max Horz 2=104(LC 8) Max Uplift 2=-172(LC 8), 6=-99(LC 8) Max Grav 2=301(LC 1), 6=243(LC 1) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. NOTES-(10) 1) Wind: ASCE 7-16; Vult=165mph (3-second gust) Vasd=128mph; TCDL=4.2psf; BCDL=3.0psf; h=15ft; B=45ft; L=28ft; eave=4ft; Cat. II; Exp B; Encl., GCpi=0.18; MWFRS (directional); cantilever left and right exposed ; end vertical left and right exposed; Lumber DOL=1.60 plate grip DOL=1.60 2) Truss designed for wind loads in the plane of the truss only. For studs exposed to wind (normal to the face), see Standard Industry Gable End Details as applicable, or consult qualified building designer as per ANSI/TPI 1. 3) Building Designer / Project engineer responsible for verifying applied roof live load shown covers rain loading requirements specific to the use of this truss component. 4) Gable studs spaced at 2-0-0 oc. 5) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 6) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 7) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 172 lb uplift at joint 2 and 99 lb uplift at joint 6. 8) Hanger(s) or other connection device(s) shall be provided sufficient to support concentrated load(s) 79 lb up at 1-5-12, 79 lb up at 1-5-12, and 44 lb up at 4-3-11, and 44 lb up at 4-3-11 on top chord, and at 1-5-12, at 1-5-12, and at 4-3-11, and at 4-3-11 on bottom chord. The design/selection of such connection device(s) is the responsibility of others. 9) In the LOAD CASE(S) section, loads applied to the face of the truss are noted as front (F) or back (B). 10) "This manufactured product is designed as an individual building component. The suitability and use of this component for any particular building is the responsibility of the building designer per ANSI TPI 1 as referenced by the building code." LOAD CASE(S) Standard 1) Dead + Roof Live (balanced): Lumber Increase=1.25, Plate Increase=1.25 Uniform Loads (plf) Vert: 1-3=-54, 3-4=-14, 2-5=-20 Concentrated Loads (lb) Vert: 7=44(F=22, B=22) This item has been electronically signed and sealed by Velez, Joaquin, PE using a Digital Signature. Printed copies of this document are not considered signed and sealed and the signature must be verified on any electronic copies. April 9,2021 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component available from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 5/19/2020 BEFORE USE. 6904 Parke East Blvd. Tampa, FL 36610 Job WS0024 Truss HJ7 Truss Type Diagonal Hip Girder Qty 5 Ply 1 Job Reference (optional) T23501817 8.430 s Mar 22 2021 MiTek Industries, Inc. Thu Apr 8 08:14:44 2021 Page 1 Builders FirstSource (Tampa, FL), Tampa, FL - 33564, ID:JbsSUYEphcZuYTshvwE3BRyhOBX-Uf7xrP?QpudfNTecU8uwfHuc1vk0sU7gZMa_m5zSqyv Scale = 1:20.6 1 2 3 7 6 8 9 10 4 11 12 13 52x4 3x4 3x4 2x4 5-8-1 5-8-1 9-10-1 4-1-15 -1-5-0 1-5-0 5-8-1 5-8-1 9-10-1 4-1-15 0-4-13-2-133.54 12 LOADING (psf) TCLL TCDL BCLL BCDL 20.0 7.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.25 1.25 NO FBC2020/TPI2014 CSI. TC BC WB Matrix-SH 0.29 0.38 0.27 DEFL. Vert(LL) Vert(CT) Horz(CT) in -0.02 -0.05 0.01 (loc) 6-7 6-7 5 l/defl >999 >999 n/a L/d 240 180 n/a PLATES MT20 Weight: 40 lb FT = 20% GRIP 244/190 LUMBER- TOP CHORD 2x4 SP No.2 BOT CHORD 2x4 SP No.2 WEBS 2x4 SP No.3 BRACING- TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS. (size)4=Mechanical, 2=0-10-15, 5=Mechanical Max Horz 2=135(LC 8) Max Uplift 4=-68(LC 8), 2=-237(LC 8), 5=-101(LC 8) Max Grav 4=104(LC 1), 2=445(LC 1), 5=310(LC 1) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 2-3=-714/203 BOT CHORD 2-7=-269/652, 6-7=-269/652 WEBS 3-6=-713/294, 3-7=0/290 NOTES-(9) 1) Wind: ASCE 7-16; Vult=165mph (3-second gust) Vasd=128mph; TCDL=4.2psf; BCDL=3.0psf; h=15ft; B=45ft; L=28ft; eave=4ft; Cat. II; Exp B; Encl., GCpi=0.18; MWFRS (directional); cantilever left and right exposed ; end vertical left and right exposed; Lumber DOL=1.60 plate grip DOL=1.60 2) Building Designer / Project engineer responsible for verifying applied roof live load shown covers rain loading requirements specific to the use of this truss component. 3) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 4) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 5) Refer to girder(s) for truss to truss connections. 6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 68 lb uplift at joint 4, 237 lb uplift at joint 2 and 101 lb uplift at joint 5. 7) Hanger(s) or other connection device(s) shall be provided sufficient to support concentrated load(s) 78 lb up at 1-4-15, 78 lb up at 1-4-15, 44 lb up at 4-2-15, 44 lb up at 4-2-15, and 38 lb down and 99 lb up at 7-0-14, and 38 lb down and 99 lb up at 7-0-14 on top chord, and at 1-4-15, at 1-4-15, at 4-2-15, at 4-2-15, and 36 lb down at 7-0-14, and 36 lb down at 7-0-14 on bottom chord. The design/selection of such connection device(s) is the responsibility of others. 8) In the LOAD CASE(S) section, loads applied to the face of the truss are noted as front (F) or back (B). 9) "This manufactured product is designed as an individual building component. The suitability and use of this component for any particular building is the responsibility of the building designer per ANSI TPI 1 as referenced by the building code." LOAD CASE(S) Standard 1) Dead + Roof Live (balanced): Lumber Increase=1.25, Plate Increase=1.25 Uniform Loads (plf) Vert: 1-4=-54, 2-5=-20 Concentrated Loads (lb) Vert: 8=44(F=22, B=22) 10=-75(F=-38, B=-38) 13=-36(F=-18, B=-18) This item has been electronically signed and sealed by Velez, Joaquin, PE using a Digital Signature. Printed copies of this document are not considered signed and sealed and the signature must be verified on any electronic copies. April 9,2021 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component available from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 5/19/2020 BEFORE USE. 6904 Parke East Blvd. Tampa, FL 36610 Job WS0024 Truss T01 Truss Type Hip Girder Qty 1 Ply 1 Job Reference (optional) T23501818 8.430 s Mar 22 2021 MiTek Industries, Inc. Thu Apr 8 08:14:45 2021 Page 1 Builders FirstSource (Tampa, FL), Tampa, FL - 33564, ID:JbsSUYEphcZuYTshvwE3BRyhOBX-yshJ2l02ZBlW_dDp2sP9BVQc3Iyebylqo0JXIYzSqyu Scale: 3/8"=1' 1 2 3 4 5 7 6 8 9 10 11 12 3x6 ST1.5x8 STP 5x6 5x6 3x4 5x6 3x6 7-0-0 7-0-0 11-8-0 4-8-0 18-8-0 7-0-0 7-0-0 7-0-0 11-8-0 4-8-0 18-8-0 7-0-0 19-8-0 1-0-0 0-4-13-3-10-4-13-3-15.00 12 Plate Offsets (X,Y)-- [1:0-0-14,0-0-2], [2:0-3-0,0-2-4], [3:0-3-0,0-2-4], [7:0-3-0,0-3-0] LOADING (psf) TCLL TCDL BCLL BCDL 20.0 7.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.25 1.25 NO FBC2020/TPI2014 CSI. TC BC WB Matrix-SH 0.98 0.94 0.25 DEFL. Vert(LL) Vert(CT) Horz(CT) in 0.11 -0.21 0.07 (loc) 1-7 6-7 4 l/defl >999 >999 n/a L/d 240 180 n/a PLATES MT20 Weight: 75 lb FT = 20% GRIP 244/190 LUMBER- TOP CHORD 2x4 SP No.1 *Except* 2-3: 2x4 SP No.2 BOT CHORD 2x4 SP No.2 WEBS 2x4 SP No.3 BRACING- TOP CHORD Structural wood sheathing directly applied. BOT CHORD Rigid ceiling directly applied or 6-4-9 oc bracing. REACTIONS. (size)1=Mechanical, 4=0-8-0 Max Horz 1=-79(LC 6) Max Uplift 1=-449(LC 8), 4=-536(LC 8) Max Grav 1=1283(LC 1), 4=1385(LC 1) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 1-2=-2788/972, 2-3=-2443/930, 3-4=-2773/972 BOT CHORD 1-7=-804/2500, 6-7=-800/2469, 4-6=-796/2470 WEBS 2-7=-60/647, 3-6=-54/651 NOTES-(11) 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-16; Vult=165mph (3-second gust) Vasd=128mph; TCDL=4.2psf; BCDL=3.0psf; h=15ft; B=45ft; L=28ft; eave=4ft; Cat. II; Exp B; Encl., GCpi=0.18; MWFRS (directional); cantilever left and right exposed ; end vertical left and right exposed; Lumber DOL=1.60 plate grip DOL=1.60 3) Building Designer / Project engineer responsible for verifying applied roof live load shown covers rain loading requirements specific to the use of this truss component. 4) Provide adequate drainage to prevent water ponding. 5) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 6) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 7) Refer to girder(s) for truss to truss connections. 8) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 449 lb uplift at joint 1 and 536 lb uplift at joint 4. 9) Hanger(s) or other connection device(s) shall be provided sufficient to support concentrated load(s) 124 lb down and 122 lb up at 7-0-0, 105 lb down and 118 lb up at 9-0-12, and 105 lb down and 118 lb up at 9-7-4, and 180 lb down and 216 lb up at 11-8-0 on top chord, and 340 lb down and 129 lb up at 7-0-0, 81 lb down at 9-0-12, and 81 lb down at 9-7-4, and 340 lb down and 129 lb up at 11-7-4 on bottom chord. The design/selection of such connection device(s) is the responsibility of others. 10) In the LOAD CASE(S) section, loads applied to the face of the truss are noted as front (F) or back (B). 11) "This manufactured product is designed as an individual building component. The suitability and use of this component for any particular building is the responsibility of the building designer per ANSI TPI 1 as referenced by the building code." LOAD CASE(S) Standard Continued on page 2 This item has been electronically signed and sealed by Velez, Joaquin, PE using a Digital Signature. Printed copies of this document are not considered signed and sealed and the signature must be verified on any electronic copies. April 9,2021 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component available from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 5/19/2020 BEFORE USE. 6904 Parke East Blvd. Tampa, FL 36610 Job WS0024 Truss T01 Truss Type Hip Girder Qty 1 Ply 1 Job Reference (optional) T23501818 8.430 s Mar 22 2021 MiTek Industries, Inc. Thu Apr 8 08:14:45 2021 Page 2 Builders FirstSource (Tampa, FL), Tampa, FL - 33564, ID:JbsSUYEphcZuYTshvwE3BRyhOBX-yshJ2l02ZBlW_dDp2sP9BVQc3Iyebylqo0JXIYzSqyu LOAD CASE(S) Standard 1) Dead + Roof Live (balanced): Lumber Increase=1.25, Plate Increase=1.25 Uniform Loads (plf) Vert: 1-2=-54, 2-3=-54, 3-5=-54, 1-4=-20 Concentrated Loads (lb) Vert: 3=-133(F) 7=-340(F) 6=-340(F) 2=-105(F) 9=-105(F) 10=-105(F) 11=-58(F) 12=-58(F) Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component available from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 5/19/2020 BEFORE USE. 6904 Parke East Blvd. Tampa, FL 36610 Job WS0024 Truss T02 Truss Type Jack-Open Girder Qty 1 Ply 1 Job Reference (optional) T23501819 8.430 s Mar 22 2021 MiTek Industries, Inc. Thu Apr 8 08:14:45 2021 Page 1 Builders FirstSource (Tampa, FL), Tampa, FL - 33564, ID:JbsSUYEphcZuYTshvwE3BRyhOBX-yshJ2l02ZBlW_dDp2sP9BVQfGI?ib?wqo0JXIYzSqyu Scale = 1:21.0 1 2 3 5 467 3x4 ST1.5x8 STP 2x4 2x4 2x4 2x4 5-0-12 5-0-12 7-0-0 1-11-4 5-0-12 5-0-12 7-0-0 1-11-4 0-4-13-3-15.00 12 Plate Offsets (X,Y)-- [1:0-4-5,0-1-2] LOADING (psf) TCLL TCDL BCLL BCDL 20.0 7.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.25 1.25 NO FBC2020/TPI2014 CSI. TC BC WB Matrix-SH 0.77 0.74 0.04 DEFL. Vert(LL) Vert(CT) Horz(CT) in 0.16 -0.29 0.00 (loc) 1-5 1-5 l/defl >481 >267 n/a L/d 240 180 n/a PLATES MT20 Weight: 34 lb FT = 20% GRIP 244/190 LUMBER- TOP CHORD 2x4 SP No.2 BOT CHORD 2x6 SP M 26 WEBS 2x4 SP No.3 BRACING- TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins. BOT CHORD Rigid ceiling directly applied or 7-0-6 oc bracing. REACTIONS. (size)1=0-8-0, 4=Mechanical Max Horz 1=108(LC 8) Max Uplift 1=-235(LC 8), 4=-456(LC 8) Max Grav 1=757(LC 1), 4=1235(LC 1) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. NOTES-(9) 1) Wind: ASCE 7-16; Vult=165mph (3-second gust) Vasd=128mph; TCDL=4.2psf; BCDL=3.0psf; h=15ft; B=45ft; L=28ft; eave=4ft; Cat. II; Exp B; Encl., GCpi=0.18; MWFRS (directional); cantilever left and right exposed ; end vertical left and right exposed; Lumber DOL=1.60 plate grip DOL=1.60 2) Building Designer / Project engineer responsible for verifying applied roof live load shown covers rain loading requirements specific to the use of this truss component. 3) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 4) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 5) Refer to girder(s) for truss to truss connections. 6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 235 lb uplift at joint 1 and 456 lb uplift at joint 4. 7) Hanger(s) or other connection device(s) shall be provided sufficient to support concentrated load(s) 86 lb down and 44 lb up at 1-1-1, and 160 lb down and 62 lb up at 3-1-1, and 1263 lb down and 469 lb up at 5-0-12 on bottom chord. The design/selection of such connection device(s) is the responsibility of others. 8) In the LOAD CASE(S) section, loads applied to the face of the truss are noted as front (F) or back (B). 9) "This manufactured product is designed as an individual building component. The suitability and use of this component for any particular building is the responsibility of the building designer per ANSI TPI 1 as referenced by the building code." LOAD CASE(S) Standard 1) Dead + Roof Live (balanced): Lumber Increase=1.25, Plate Increase=1.25 Uniform Loads (plf) Vert: 1-3=-54, 1-4=-20 Concentrated Loads (lb) Vert: 5=-1263(F) 6=-86(F) 7=-160(F) This item has been electronically signed and sealed by Velez, Joaquin, PE using a Digital Signature. Printed copies of this document are not considered signed and sealed and the signature must be verified on any electronic copies. April 9,2021 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component available from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 5/19/2020 BEFORE USE. 6904 Parke East Blvd. Tampa, FL 36610 Job WS0024 Truss T03 Truss Type Roof Special Girder Qty 1 Ply 1 Job Reference (optional) T23501820 8.430 s Mar 22 2021 MiTek Industries, Inc. Thu Apr 8 08:14:46 2021 Page 1 Builders FirstSource (Tampa, FL), Tampa, FL - 33564, ID:JbsSUYEphcZuYTshvwE3BRyhOBX-Q2FhG51gKVtNcno?cZxOkiztViO9KDEz1g34q_zSqyt Scale = 1:57.1 1 2 3 4 5 6 7 8 9 10 14 13 12 11 15 16 17 18 19 20 21 5x6 ST1.5x8 STP ST1.5x8 STP 5x6 4x6 3x12 MT20HS 4x6 2x4 8x14 MT20HS 5x8 2x4 3x8 3x6 3x8 7-0-0 7-0-0 11-11-14 4-11-14 15-4-13 3-5-0 18-8-0 3-3-3 20-8-0 2-0-0 21-0-0 0-4-0 21-4-0 0-4-0 30-4-0 9-0-0 -1-0-0 1-0-0 4-3-7 4-3-7 7-0-0 2-8-9 11-11-14 4-11-14 15-4-13 3-5-0 18-8-0 3-3-3 20-8-0 2-0-0 21-0-0 0-4-0 21-4-0 0-4-0 24-5-13 3-1-13 30-4-0 5-10-3 31-4-0 1-0-0 0-4-13-3-14-1-10-4-13-3-15.00 12 Plate Offsets (X,Y)-- [2:0-3-0,0-1-8], [3:0-3-0,0-2-4], [9:0-3-1,0-1-8], [12:0-7-0,0-4-8], [13:0-4-4,0-1-8] LOADING (psf) TCLL TCDL BCLL BCDL 20.0 7.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.25 1.25 NO FBC2020/TPI2014 CSI. TC BC WB Matrix-SH 0.62 0.53 1.00 DEFL. Vert(LL) Vert(CT) Horz(CT) in -0.31 -0.57 0.11 (loc) 12 12-13 9 l/defl >999 >623 n/a L/d 240 180 n/a PLATES MT20 MT20HS Weight: 169 lb FT = 20% GRIP 244/190 187/143 LUMBER- TOP CHORD 2x4 SP M 31 *Except* 6-7,7-10: 2x4 SP No.2 BOT CHORD 2x6 SP M 26 WEBS 2x4 SP No.3 BRACING- TOP CHORD Structural wood sheathing directly applied or 2-6-15 oc purlins. BOT CHORD Rigid ceiling directly applied or 6-5-0 oc bracing. WEBS 1 Row at midpt 4-14 REACTIONS. (size)2=0-8-0, 9=0-8-0 Max Horz 2=-103(LC 6) Max Uplift 2=-920(LC 8), 9=-678(LC 8) Max Grav 2=2486(LC 1), 9=1840(LC 1) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 2-3=-5595/1963, 3-4=-5155/1868, 4-5=-6159/2218, 5-6=-6159/2218, 6-7=-3664/1305, 7-8=-3697/1304, 8-9=-3928/1384 BOT CHORD 2-14=-1705/5069, 13-14=-2388/6954, 12-13=-2388/6954, 11-12=-1753/5263, 9-11=-1185/3549 WEBS 3-14=-482/1697, 6-12=-435/1275, 6-11=-2994/1118, 8-11=-269/163, 4-12=-1120/652, 7-11=-907/2627, 4-13=-407/1350, 4-14=-2094/766 NOTES-(11) 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-16; Vult=165mph (3-second gust) Vasd=128mph; TCDL=4.2psf; BCDL=3.0psf; h=15ft; B=45ft; L=28ft; eave=4ft; Cat. II; Exp B; Encl., GCpi=0.18; MWFRS (directional); cantilever left and right exposed ; end vertical left and right exposed; Lumber DOL=1.60 plate grip DOL=1.60 3) Building Designer / Project engineer responsible for verifying applied roof live load shown covers rain loading requirements specific to the use of this truss component. 4) Provide adequate drainage to prevent water ponding. 5) All plates are MT20 plates unless otherwise indicated. 6) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 7) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 8) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 920 lb uplift at joint 2 and 678 lb uplift at joint 9. 9) Hanger(s) or other connection device(s) shall be provided sufficient to support concentrated load(s) 145 lb down and 122 lb up at 7-0-0, and 145 lb down and 118 lb up at 9-0-12, and 145 lb down and 118 lb up at 11-0-12 on top chord, and 340 lb down and 129 lb up at 7-0-0, 81 lb down at 9-0-12, and 81 lb down at 11-0-12, and 1215 lb down and 476 lb up at 11-7-4 on bottom chord. The design/selection of such connection device(s) is the responsibility of others. 10) In the LOAD CASE(S) section, loads applied to the face of the truss are noted as front (F) or back (B). 11) "This manufactured product is designed as an individual building component. The suitability and use of this component for any particular building is the responsibility of the building designer per ANSI TPI 1 as referenced by the building code." LOAD CASE(S) StandardContinued on page 2 This item has been electronically signed and sealed by Velez, Joaquin, PE using a Digital Signature. Printed copies of this document are not considered signed and sealed and the signature must be verified on any electronic copies. April 9,2021 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component available from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 5/19/2020 BEFORE USE. 6904 Parke East Blvd. Tampa, FL 36610 Job WS0024 Truss T03 Truss Type Roof Special Girder Qty 1 Ply 1 Job Reference (optional) T23501820 8.430 s Mar 22 2021 MiTek Industries, Inc. Thu Apr 8 08:14:46 2021 Page 2 Builders FirstSource (Tampa, FL), Tampa, FL - 33564, ID:JbsSUYEphcZuYTshvwE3BRyhOBX-Q2FhG51gKVtNcno?cZxOkiztViO9KDEz1g34q_zSqyt LOAD CASE(S) Standard 1) Dead + Roof Live (balanced): Lumber Increase=1.25, Plate Increase=1.25 Uniform Loads (plf) Vert: 1-3=-54, 3-6=-54, 6-7=-54, 7-10=-54, 2-9=-20 Concentrated Loads (lb) Vert: 3=-105(F) 14=-340(F) 15=-105(F) 16=-105(F) 19=-58(F) 20=-58(F) 21=-1215(F) Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component available from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 5/19/2020 BEFORE USE. 6904 Parke East Blvd. Tampa, FL 36610 Job WS0024 Truss T04 Truss Type Roof Special Qty 1 Ply 1 Job Reference (optional) T23501821 8.430 s Mar 22 2021 MiTek Industries, Inc. Thu Apr 8 08:14:47 2021 Page 1 Builders FirstSource (Tampa, FL), Tampa, FL - 33564, ID:JbsSUYEphcZuYTshvwE3BRyhOBX-uEp3TR2I5p?EExNB9HSdGwW5u6fi3su7FKoeNQzSqys Scale = 1:55.0 1 2 3 4 5 6 7 8 9 12 11 10 13 14 15 16 17 18 19 20 5x8 ST1.5x8 STP ST1.5x8 STP 5x8 3x6 3x4 2x4 5x8 2x4 3x6 3x4 2x4 9-0-0 9-0-0 15-2-0 6-2-0 20-8-0 5-6-0 21-4-0 0-8-0 30-4-0 9-0-0 -1-0-0 1-0-0 5-8-11 5-8-11 9-0-0 3-3-5 15-2-0 6-2-0 20-8-0 5-6-0 21-0-0 0-4-0 21-4-0 0-4-0 24-7-6 3-3-6 30-4-0 5-8-10 31-4-0 1-0-0 0-4-14-1-10-4-14-1-15.00 12 Plate Offsets (X,Y)-- [4:0-5-12,0-2-8], [6:0-5-12,0-2-8], [7:0-0-0,0-0-0], [11:0-4-0,0-3-0] LOADING (psf) TCLL TCDL BCLL BCDL 20.0 7.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.25 1.25 YES FBC2020/TPI2014 CSI. TC BC WB Matrix-SH 0.45 0.83 0.21 DEFL. Vert(LL) Vert(CT) Horz(CT) in -0.17 -0.38 0.09 (loc) 2-12 2-12 8 l/defl >999 >948 n/a L/d 240 180 n/a PLATES MT20 Weight: 144 lb FT = 20% GRIP 244/190 LUMBER- TOP CHORD 2x4 SP No.2 BOT CHORD 2x4 SP No.2 WEBS 2x4 SP No.3 BRACING- TOP CHORD Structural wood sheathing directly applied or 3-5-3 oc purlins. BOT CHORD Rigid ceiling directly applied or 6-7-14 oc bracing. REACTIONS. (size)2=0-8-0, 8=0-8-0 Max Horz 2=100(LC 11) Max Uplift 2=-427(LC 12), 8=-427(LC 12) Max Grav 2=1170(LC 1), 8=1170(LC 1) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 2-3=-2221/925, 3-4=-1995/830, 4-5=-2192/960, 5-6=-2192/960, 6-7=-1995/830, 7-8=-2221/925 BOT CHORD 2-12=-770/1990, 11-12=-611/1814, 10-11=-615/1814, 8-10=-775/1990 WEBS 4-12=-63/378, 4-11=-202/542, 5-11=-380/235, 6-11=-202/542, 6-10=-63/377 NOTES-(8) 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-16; Vult=165mph (3-second gust) Vasd=128mph; TCDL=4.2psf; BCDL=3.0psf; h=15ft; B=45ft; L=28ft; eave=4ft; Cat. II; Exp B; Encl., GCpi=0.18; MWFRS (directional) and C-C Exterior(2E) -1-0-0 to 2-0-0, Interior(1) 2-0-0 to 9-0-0, Exterior(2R) 9-0-0 to 12-0-0, Interior(1) 12-0-0 to 21-4-0, Exterior(2R) 21-4-0 to 24-4-0, Interior(1) 24-4-0 to 31-4-0 zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) Building Designer / Project engineer responsible for verifying applied roof live load shown covers rain loading requirements specific to the use of this truss component. 4) Provide adequate drainage to prevent water ponding. 5) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 6) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 7) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 427 lb uplift at joint 2 and 427 lb uplift at joint 8. 8) "This manufactured product is designed as an individual building component. The suitability and use of this component for any particular building is the responsibility of the building designer per ANSI TPI 1 as referenced by the building code." This item has been electronically signed and sealed by Velez, Joaquin, PE using a Digital Signature. Printed copies of this document are not considered signed and sealed and the signature must be verified on any electronic copies. April 9,2021 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component available from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 5/19/2020 BEFORE USE. 6904 Parke East Blvd. Tampa, FL 36610 Job WS0024 Truss T05 Truss Type Hip Qty 1 Ply 1 Job Reference (optional) T23501822 8.430 s Mar 22 2021 MiTek Industries, Inc. Thu Apr 8 08:14:48 2021 Page 1 Builders FirstSource (Tampa, FL), Tampa, FL - 33564, ID:JbsSUYEphcZuYTshvwE3BRyhOBX-MRNShn2ws675r5yOj_zsp72E4W24oJMGUzYBvszSqyr Scale = 1:54.8 1 2 3 4 5 6 7 8 13 12 11 10 9 14 15 16 3x4 ST1.5x8 STP ST1.5x8 STP 4x6 4x6 4x6 3x4 2x4 3x8 3x4 3x8 3x4 2x4 3x4 6-6-5 6-6-5 11-0-0 4-5-11 19-4-0 8-4-0 23-9-11 4-5-11 30-4-0 6-6-5 6-6-5 6-6-5 11-0-0 4-5-11 15-2-0 4-2-0 19-4-0 4-2-0 23-9-11 4-5-11 30-4-0 6-6-5 31-4-0 1-0-0 0-4-14-11-10-4-14-11-15.00 12 Plate Offsets (X,Y)-- [1:0-3-0,0-1-8], [7:0-3-0,0-1-8] LOADING (psf) TCLL TCDL BCLL BCDL 20.0 7.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.25 1.25 YES FBC2020/TPI2014 CSI. TC BC WB Matrix-SH 0.55 0.70 0.26 DEFL. Vert(LL) Vert(CT) Horz(CT) in -0.15 -0.36 0.09 (loc) 10-12 10-12 7 l/defl >999 >999 n/a L/d 240 180 n/a PLATES MT20 Weight: 147 lb FT = 20% GRIP 244/190 LUMBER- TOP CHORD 2x4 SP No.2 BOT CHORD 2x4 SP No.2 WEBS 2x4 SP No.3 BRACING- TOP CHORD Structural wood sheathing directly applied or 3-1-9 oc purlins. BOT CHORD Rigid ceiling directly applied or 6-9-5 oc bracing. REACTIONS. (size)1=0-8-0, 7=0-8-0 Max Horz 1=-119(LC 10) Max Uplift 1=-357(LC 12), 7=-428(LC 12) Max Grav 1=1096(LC 1), 7=1171(LC 1) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 1-2=-2277/886, 2-3=-1829/764, 3-4=-1650/736, 4-5=-1648/741, 5-6=-1826/763, 6-7=-2262/885 BOT CHORD 1-13=-725/2024, 12-13=-725/2024, 10-12=-594/1755, 9-10=-733/2009, 7-9=-733/2009 WEBS 2-12=-461/252, 3-12=-163/486, 4-12=-267/113, 4-10=-269/117, 5-10=-160/484, 6-10=-446/244 NOTES-(8) 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-16; Vult=165mph (3-second gust) Vasd=128mph; TCDL=4.2psf; BCDL=3.0psf; h=15ft; B=45ft; L=28ft; eave=4ft; Cat. II; Exp B; Encl., GCpi=0.18; MWFRS (directional) and C-C Exterior(2E) 0-4-0 to 3-4-0, Interior(1) 3-4-0 to 11-0-0, Exterior(2R) 11-0-0 to 15-2-0, Interior(1) 15-2-0 to 19-4-0, Exterior(2R) 19-4-0 to 23-9-11, Interior(1) 23-9-11 to 31-4-0 zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) Building Designer / Project engineer responsible for verifying applied roof live load shown covers rain loading requirements specific to the use of this truss component. 4) Provide adequate drainage to prevent water ponding. 5) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 6) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 7) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 357 lb uplift at joint 1 and 428 lb uplift at joint 7. 8) "This manufactured product is designed as an individual building component. The suitability and use of this component for any particular building is the responsibility of the building designer per ANSI TPI 1 as referenced by the building code." This item has been electronically signed and sealed by Velez, Joaquin, PE using a Digital Signature. Printed copies of this document are not considered signed and sealed and the signature must be verified on any electronic copies. April 9,2021 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component available from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 5/19/2020 BEFORE USE. 6904 Parke East Blvd. Tampa, FL 36610 Job WS0024 Truss T06 Truss Type Hip Qty 1 Ply 1 Job Reference (optional) T23501823 8.430 s Mar 22 2021 MiTek Industries, Inc. Thu Apr 8 08:14:49 2021 Page 1 Builders FirstSource (Tampa, FL), Tampa, FL - 33564, ID:JbsSUYEphcZuYTshvwE3BRyhOBX-rdxqu73ZdQGyTFXaHiU5MLbM7vLxXiFQjdHlRJzSqyq Scale = 1:54.8 1 2 3 4 5 6 7 12 11 10 9 8 13 14 15 16 17 18 3x4 ST1.5x8 STP ST1.5x8 STP 5x8 4x6 3x6 3x4 2x4 3x4 3x8 3x4 2x4 3x4 7-7-12 7-7-12 13-0-0 5-4-4 17-4-0 4-4-0 22-8-4 5-4-4 30-4-0 7-7-12 7-7-12 7-7-12 13-0-0 5-4-4 17-4-0 4-4-0 22-8-4 5-4-4 30-4-0 7-7-12 31-4-0 1-0-0 0-4-15-9-10-4-15-9-15.00 12 Plate Offsets (X,Y)-- [1:0-1-10,Edge], [3:0-5-12,0-2-8], [6:0-3-0,0-1-8] LOADING (psf) TCLL TCDL BCLL BCDL 20.0 7.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.25 1.25 YES FBC2020/TPI2014 CSI. TC BC WB Matrix-SH 0.72 0.78 0.47 DEFL. Vert(LL) Vert(CT) Horz(CT) in -0.13 -0.27 0.09 (loc) 9-11 1-12 6 l/defl >999 >999 n/a L/d 240 180 n/a PLATES MT20 Weight: 147 lb FT = 20% GRIP 244/190 LUMBER- TOP CHORD 2x4 SP No.2 BOT CHORD 2x4 SP No.2 WEBS 2x4 SP No.3 BRACING- TOP CHORD Structural wood sheathing directly applied or 2-7-0 oc purlins. BOT CHORD Rigid ceiling directly applied or 6-9-6 oc bracing. REACTIONS. (size)1=0-8-0, 6=0-8-0 Max Horz 1=-139(LC 10) Max Uplift 1=-357(LC 12), 6=-428(LC 12) Max Grav 1=1096(LC 1), 6=1171(LC 1) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 1-2=-2235/865, 2-3=-1651/721, 3-4=-1470/708, 4-5=-1651/724, 5-6=-2223/866 BOT CHORD 1-12=-697/1980, 11-12=-697/1980, 9-11=-450/1470, 8-9=-707/1967, 6-8=-707/1967 WEBS 2-12=0/292, 2-11=-610/294, 3-11=-117/390, 4-9=-121/390, 5-9=-596/286, 5-8=0/290 NOTES-(8) 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-16; Vult=165mph (3-second gust) Vasd=128mph; TCDL=4.2psf; BCDL=3.0psf; h=15ft; B=45ft; L=28ft; eave=4ft; Cat. II; Exp B; Encl., GCpi=0.18; MWFRS (directional) and C-C Exterior(2E) 0-4-0 to 3-4-0, Interior(1) 3-4-0 to 13-0-0, Exterior(2E) 13-0-0 to 17-4-0, Exterior(2R) 17-4-0 to 21-6-15, Interior(1) 21-6-15 to 31-4-0 zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) Building Designer / Project engineer responsible for verifying applied roof live load shown covers rain loading requirements specific to the use of this truss component. 4) Provide adequate drainage to prevent water ponding. 5) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 6) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 7) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 357 lb uplift at joint 1 and 428 lb uplift at joint 6. 8) "This manufactured product is designed as an individual building component. The suitability and use of this component for any particular building is the responsibility of the building designer per ANSI TPI 1 as referenced by the building code." This item has been electronically signed and sealed by Velez, Joaquin, PE using a Digital Signature. Printed copies of this document are not considered signed and sealed and the signature must be verified on any electronic copies. April 9,2021 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component available from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 5/19/2020 BEFORE USE. 6904 Parke East Blvd. Tampa, FL 36610 Job WS0024 Truss T07 Truss Type Hip Qty 1 Ply 1 Job Reference (optional) T23501824 8.430 s Mar 22 2021 MiTek Industries, Inc. Thu Apr 8 08:14:50 2021 Page 1 Builders FirstSource (Tampa, FL), Tampa, FL - 33564, ID:JbsSUYEphcZuYTshvwE3BRyhOBX-JpVC5T4BOkOp5O5mrP?KuY8TWJfMG5uZyH1IzlzSqyp Scale = 1:53.8 1 2 3 4 5 6 7 8 11 10 9 12 13 14 15 3x6 ST1.5x8 STP ST1.5x8 STP 4x6 3x6 3x6 3x4 2x4 5x8 3x4 2x4 3x6 8-9-6 8-9-6 15-0-0 6-2-10 15-2-0 0-2-0 15-4-0 0-2-0 21-6-10 6-2-10 30-4-0 8-9-6 8-9-6 8-9-6 15-0-0 6-2-10 15-2-0 0-2-0 15-4-0 0-2-0 21-6-10 6-2-10 30-4-0 8-9-6 31-4-0 1-0-0 0-4-16-7-140-4-15.00 12 Plate Offsets (X,Y)-- [10:0-4-0,0-3-0] LOADING (psf) TCLL TCDL BCLL BCDL 20.0 7.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.25 1.25 YES FBC2020/TPI2014 CSI. TC BC WB Matrix-SH 1.00 0.90 0.77 DEFL. Vert(LL) Vert(CT) Horz(CT) in 0.18 -0.38 0.09 (loc) 1-11 1-11 7 l/defl >999 >931 n/a L/d 240 180 n/a PLATES MT20 Weight: 136 lb FT = 20% GRIP 244/190 LUMBER- TOP CHORD 2x4 SP No.2 BOT CHORD 2x4 SP No.2 WEBS 2x4 SP No.3 BRACING- TOP CHORD Structural wood sheathing directly applied. BOT CHORD Rigid ceiling directly applied or 6-11-6 oc bracing. REACTIONS. (size)1=0-8-0, 7=0-8-0 Max Horz 1=-160(LC 10) Max Uplift 1=-357(LC 12), 7=-428(LC 12) Max Grav 1=1096(LC 1), 7=1171(LC 1) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 1-2=-2179/808, 2-4=-1482/632, 4-6=-1481/626, 6-7=-2170/798 BOT CHORD 1-11=-631/1922, 10-11=-631/1922, 9-10=-635/1912, 7-9=-635/1912 WEBS 2-11=0/338, 2-10=-742/350, 6-10=-731/345, 6-9=0/337, 4-10=-296/812 NOTES-(7) 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-16; Vult=165mph (3-second gust) Vasd=128mph; TCDL=4.2psf; BCDL=3.0psf; h=15ft; B=45ft; L=28ft; eave=4ft; Cat. II; Exp B; Encl., GCpi=0.18; MWFRS (directional) and C-C Exterior(2E) 0-4-0 to 3-4-0, Interior(1) 3-4-0 to 15-2-0, Exterior(2R) 15-2-0 to 19-4-15, Interior(1) 19-4-15 to 31-4-0 zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) Building Designer / Project engineer responsible for verifying applied roof live load shown covers rain loading requirements specific to the use of this truss component. 4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 5) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 357 lb uplift at joint 1 and 428 lb uplift at joint 7. 7) "This manufactured product is designed as an individual building component. The suitability and use of this component for any particular building is the responsibility of the building designer per ANSI TPI 1 as referenced by the building code." This item has been electronically signed and sealed by Velez, Joaquin, PE using a Digital Signature. Printed copies of this document are not considered signed and sealed and the signature must be verified on any electronic copies. April 9,2021 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component available from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 5/19/2020 BEFORE USE. 6904 Parke East Blvd. Tampa, FL 36610 Job WS0024 Truss T08 Truss Type Roof Special Qty 1 Ply 1 Job Reference (optional) T23501825 8.430 s Mar 22 2021 MiTek Industries, Inc. Thu Apr 8 08:14:51 2021 Page 1 Builders FirstSource (Tampa, FL), Tampa, FL - 33564, ID:JbsSUYEphcZuYTshvwE3BRyhOBX-n?3aJp5p91WgiYgzO7WZRmgjSj3r?U_iAxmrWBzSqyo Scale = 1:64.8 1 2 3 4 5 6 7 8 9 10 16 15 14 13 12 11 17 18 19 20 21 22 23 24 25 5x12 ST1.5x8 STP ST1.5x8 STP ST1.5x8 STP 4x6 4x6 3x6 3x4 3x6 2x4 5x12 3x4 3x4 5x6 3x4 3x4 2x4 5-0-0 5-0-0 9-8-0 4-8-0 16-3-11 6-7-11 23-4-5 7-0-11 29-9-13 6-5-8 35-0-0 5-2-3 -1-0-0 1-0-0 5-0-0 5-0-0 9-8-0 4-8-0 12-2-8 2-6-9 19-10-0 7-7-8 27-5-8 7-7-8 35-0-0 7-6-8 36-0-0 1-0-0 0-4-12-5-16-7-140-4-12-5-15.00 12 Plate Offsets (X,Y)-- [2:0-2-0,Edge], [3:0-10-4,0-2-12], [9:0-3-0,0-1-8], [12:0-3-0,0-3-0] LOADING (psf) TCLL TCDL BCLL BCDL 20.0 7.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.25 1.25 YES FBC2020/TPI2014 CSI. TC BC WB Matrix-SH 0.67 0.69 0.97 DEFL. Vert(LL) Vert(CT) Horz(CT) in -0.17 -0.29 0.04 (loc) 12-13 12-13 9 l/defl >999 >999 n/a L/d 240 180 n/a PLATES MT20 Weight: 171 lb FT = 20% GRIP 244/190 LUMBER- TOP CHORD 2x4 SP No.2 BOT CHORD 2x4 SP No.2 WEBS 2x4 SP No.3 BRACING- TOP CHORD Structural wood sheathing directly applied or 3-4-11 oc purlins. BOT CHORD Rigid ceiling directly applied or 4-9-4 oc bracing. REACTIONS. (size)2=0-8-0, 16=0-8-0, 9=0-8-0 Max Horz 2=-162(LC 10) Max Uplift 2=-376(LC 18), 16=-606(LC 12), 9=-398(LC 12) Max Grav 2=38(LC 12), 16=2138(LC 17), 9=1196(LC 18) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 2-3=-463/1478, 3-4=-919/374, 4-5=-1020/426, 5-6=-1517/598, 6-8=-1689/645, 8-9=-2341/754 BOT CHORD 2-16=-1294/491, 15-16=-1417/543, 13-15=-440/1435, 12-13=-285/1195, 11-12=-624/1907, 9-11=-609/2080 WEBS 3-16=-1936/752, 3-15=-883/2565, 4-15=-478/231, 5-15=-644/287, 6-13=-70/387, 6-12=-174/707, 8-12=-575/321, 8-11=0/304 NOTES-(8) 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-16; Vult=165mph (3-second gust) Vasd=128mph; TCDL=4.2psf; BCDL=3.0psf; h=15ft; B=45ft; L=28ft; eave=5ft; Cat. II; Exp B; Encl., GCpi=0.18; MWFRS (directional) and C-C Exterior(2E) -1-0-0 to 2-0-0, Interior(1) 2-0-0 to 5-0-0, Exterior(2R) 5-0-0 to 8-0-0, Interior(1) 8-0-0 to 19-10-0, Exterior(2R) 19-10-0 to 22-10-0, Interior(1) 22-10-0 to 36-0-0 zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) Building Designer / Project engineer responsible for verifying applied roof live load shown covers rain loading requirements specific to the use of this truss component. 4) Provide adequate drainage to prevent water ponding. 5) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 6) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members, with BCDL = 10.0psf. 7) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 376 lb uplift at joint 2, 606 lb uplift at joint 16 and 398 lb uplift at joint 9. 8) "This manufactured product is designed as an individual building component. The suitability and use of this component for any particular building is the responsibility of the building designer per ANSI TPI 1 as referenced by the building code." This item has been electronically signed and sealed by Velez, Joaquin, PE using a Digital Signature. Printed copies of this document are not considered signed and sealed and the signature must be verified on any electronic copies. April 9,2021 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component available from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 5/19/2020 BEFORE USE. 6904 Parke East Blvd. Tampa, FL 36610 Job WS0024 Truss T09 Truss Type Roof Special Qty 1 Ply 1 Job Reference (optional) T23501826 8.430 s Mar 22 2021 MiTek Industries, Inc. Thu Apr 8 08:14:52 2021 Page 1 Builders FirstSource (Tampa, FL), Tampa, FL - 33564, ID:JbsSUYEphcZuYTshvwE3BRyhOBX-FCcyW95RwLeXKiF9yq2ozzDrl7OVk0osPbWP2ezSqyn Scale = 1:64.8 1 2 3 4 5 6 7 8 9 14 13 12 11 10 15 16 17 18 19 20 21 22 5x6 ST1.5x8 STP ST1.5x8 STP ST1.5x8 STP 5x6 4x6 3x6 3x4 5x8 3x4 3x6 3x4 5x6 3x4 2x4 5-0-0 5-0-0 7-0-0 2-0-0 11-8-0 4-8-0 16-3-11 4-7-11 19-10-0 3-6-5 23-4-5 3-6-5 29-9-12 6-5-7 35-0-0 5-2-4 -1-0-0 1-0-0 7-0-0 7-0-0 11-8-0 4-8-0 12-2-10 0-6-10 16-3-11 4-1-1 19-10-0 3-6-5 27-5-7 7-7-7 29-9-12 2-4-5 35-0-0 5-2-4 36-0-0 1-0-0 0-4-13-3-16-7-140-4-13-3-15.00 12 Plate Offsets (X,Y)-- [2:0-1-2,Edge], [3:0-3-0,0-2-4], [11:0-3-0,0-3-0], [13:0-2-0,0-3-0] LOADING (psf) TCLL TCDL BCLL BCDL 20.0 7.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.25 1.25 YES FBC2020/TPI2014 CSI. TC BC WB Matrix-SH 0.89 0.73 0.68 DEFL. Vert(LL) Vert(CT) Horz(CT) in -0.18 -0.31 0.05 (loc) 11-12 11-12 8 l/defl >999 >999 n/a L/d 240 180 n/a PLATES MT20 Weight: 170 lb FT = 20% GRIP 244/190 LUMBER- TOP CHORD 2x4 SP No.2 *Except* 4-5: 2x4 SP No.1 BOT CHORD 2x4 SP No.2 WEBS 2x4 SP No.3 BRACING- TOP CHORD Structural wood sheathing directly applied. BOT CHORD Rigid ceiling directly applied or 5-0-9 oc bracing. REACTIONS. (size)2=0-8-0, 14=0-8-0, 8=0-8-0 Max Horz 2=-162(LC 10) Max Uplift 2=-310(LC 18), 14=-557(LC 12), 8=-409(LC 12) Max Grav 2=7(LC 9), 14=2032(LC 17), 8=1226(LC 18) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 2-3=-440/1383, 3-4=-1561/667, 4-5=-1610/643, 5-7=-1769/683, 7-8=-2413/792 BOT CHORD 2-14=-1202/485, 12-13=-516/1630, 11-12=-326/1263, 10-11=-657/1975, 8-10=-644/2145 WEBS 3-14=-2138/848, 4-13=-794/367, 5-12=-79/412, 4-12=-303/181, 5-11=-168/713, 7-11=-567/315, 7-10=0/298, 3-13=-601/1791 NOTES-(8) 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-16; Vult=165mph (3-second gust) Vasd=128mph; TCDL=4.2psf; BCDL=3.0psf; h=15ft; B=45ft; L=28ft; eave=5ft; Cat. II; Exp B; Encl., GCpi=0.18; MWFRS (directional) and C-C Exterior(2E) -1-0-0 to 2-0-0, Interior(1) 2-0-0 to 7-0-0, Exterior(2R) 7-0-0 to 10-0-0, Interior(1) 10-0-0 to 19-10-0, Exterior(2R) 19-10-0 to 22-10-0, Interior(1) 22-10-0 to 36-0-0 zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) Building Designer / Project engineer responsible for verifying applied roof live load shown covers rain loading requirements specific to the use of this truss component. 4) Provide adequate drainage to prevent water ponding. 5) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 6) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members, with BCDL = 10.0psf. 7) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 310 lb uplift at joint 2, 557 lb uplift at joint 14 and 409 lb uplift at joint 8. 8) "This manufactured product is designed as an individual building component. The suitability and use of this component for any particular building is the responsibility of the building designer per ANSI TPI 1 as referenced by the building code." This item has been electronically signed and sealed by Velez, Joaquin, PE using a Digital Signature. Printed copies of this document are not considered signed and sealed and the signature must be verified on any electronic copies. April 9,2021 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component available from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 5/19/2020 BEFORE USE. 6904 Parke East Blvd. Tampa, FL 36610 Job WS0024 Truss T10 Truss Type Roof Special Qty 1 Ply 1 Job Reference (optional) T23501827 8.430 s Mar 22 2021 MiTek Industries, Inc. Thu Apr 8 08:14:53 2021 Page 1 Builders FirstSource (Tampa, FL), Tampa, FL - 33564, ID:JbsSUYEphcZuYTshvwE3BRyhOBX-jOALkU63hfmOysqLWXZ1WBm0bXj9TRL?eFFya4zSqym Scale = 1:64.8 1 2 3 4 5 6 7 8 9 10 16 15 14 13 12 11 17 18 19 20 21 22 23 24 4x6 ST1.5x8 STP ST1.5x8 STP ST1.5x8 STP 4x6 4x6 3x6 3x4 3x6 5x8 3x6 3x6 5x6 3x4 2x4 3x4 2x4 5-0-0 5-0-0 9-0-0 4-0-0 13-8-0 4-8-0 16-3-11 2-7-11 19-10-0 3-6-5 23-4-5 3-6-5 27-1-2 3-8-13 29-4-11 2-3-9 35-0-0 5-7-5 -1-0-0 1-0-0 5-5-0 5-5-0 9-0-0 3-7-0 13-8-0 4-8-0 19-10-0 6-2-0 26-0-0 6-2-0 27-1-2 1-1-2 35-0-0 7-10-14 36-0-0 1-0-0 0-4-14-1-16-7-140-4-14-1-15.00 12 Plate Offsets (X,Y)-- [9:0-0-10,Edge], [12:0-3-0,0-3-0] LOADING (psf) TCLL TCDL BCLL BCDL 20.0 7.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.25 1.25 YES FBC2020/TPI2014 CSI. TC BC WB Matrix-SH 0.88 0.83 0.78 DEFL. Vert(LL) Vert(CT) Horz(CT) in -0.17 -0.29 0.05 (loc) 12-13 12-13 9 l/defl >999 >999 n/a L/d 240 180 n/a PLATES MT20 Weight: 176 lb FT = 20% GRIP 244/190 LUMBER- TOP CHORD 2x4 SP No.2 BOT CHORD 2x4 SP No.2 WEBS 2x4 SP No.3 BRACING- TOP CHORD Structural wood sheathing directly applied. BOT CHORD Rigid ceiling directly applied or 5-6-14 oc bracing. REACTIONS. (size)2=0-8-0, 9=0-8-0, 16=0-8-0 Max Horz 2=-162(LC 10) Max Uplift 2=-275(LC 18), 9=-407(LC 12), 16=-566(LC 12) Max Grav 2=15(LC 9), 9=1230(LC 18), 16=2006(LC 17) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 2-3=-405/1244, 3-4=-721/333, 4-5=-633/326, 5-6=-1627/677, 6-8=-1800/723, 8-9=-2368/770 BOT CHORD 2-16=-1095/432, 15-16=-762/294, 13-15=-490/1573, 12-13=-316/1246, 11-12=-603/1858, 9-11=-606/2089 WEBS 3-15=-513/1564, 6-12=-232/777, 8-12=-524/304, 8-11=-5/338, 6-13=-135/492, 5-13=-252/195, 5-15=-1168/454, 3-16=-1858/723 NOTES-(8) 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-16; Vult=165mph (3-second gust) Vasd=128mph; TCDL=4.2psf; BCDL=3.0psf; h=15ft; B=45ft; L=28ft; eave=5ft; Cat. II; Exp B; Encl., GCpi=0.18; MWFRS (directional) and C-C Exterior(2E) -1-0-0 to 2-0-0, Interior(1) 2-0-0 to 9-0-0, Exterior(2R) 9-0-0 to 12-0-0, Interior(1) 12-0-0 to 19-10-0, Exterior(2R) 19-10-0 to 22-10-0, Interior(1) 22-10-0 to 36-0-0 zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) Building Designer / Project engineer responsible for verifying applied roof live load shown covers rain loading requirements specific to the use of this truss component. 4) Provide adequate drainage to prevent water ponding. 5) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 6) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members, with BCDL = 10.0psf. 7) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 275 lb uplift at joint 2, 407 lb uplift at joint 9 and 566 lb uplift at joint 16. 8) "This manufactured product is designed as an individual building component. The suitability and use of this component for any particular building is the responsibility of the building designer per ANSI TPI 1 as referenced by the building code." This item has been electronically signed and sealed by Velez, Joaquin, PE using a Digital Signature. Printed copies of this document are not considered signed and sealed and the signature must be verified on any electronic copies. April 9,2021 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component available from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 5/19/2020 BEFORE USE. 6904 Parke East Blvd. Tampa, FL 36610 Job WS0024 Truss T11 Truss Type Roof Special Qty 1 Ply 1 Job Reference (optional) T23501828 8.430 s Mar 22 2021 MiTek Industries, Inc. Thu Apr 8 08:14:54 2021 Page 1 Builders FirstSource (Tampa, FL), Tampa, FL - 33564, ID:JbsSUYEphcZuYTshvwE3BRyhOBX-Bakjxq7hSyuFa0PX4F4G3OIBTw3SCzZ9sv?W7WzSqyl Scale = 1:64.8 1 2 3 4 5 6 7 8 9 10 16 1514 13 12 11 17 18 19 20 21 22 23 24 5x8 ST1.5x8 STP ST1.5x8 STP ST1.5x8 STP 4x6 4x6 3x6 3x4 3x6 2x4 3x8 3x4 3x8 5x6 3x4 3x6 2x4 5-0-0 5-0-0 11-0-0 6-0-0 15-8-0 4-8-0 23-4-5 7-8-5 29-4-11 6-0-6 35-0-0 5-7-5 -1-0-0 1-0-0 6-8-2 6-8-2 11-0-0 4-3-14 15-8-0 4-8-0 19-10-0 4-2-0 26-0-0 6-2-0 35-0-0 9-0-0 36-0-0 1-0-0 0-4-14-11-16-7-140-4-14-11-15.00 12 Plate Offsets (X,Y)-- [4:0-5-12,0-2-8], [9:0-0-10,Edge], [12:0-3-0,0-3-0] LOADING (psf) TCLL TCDL BCLL BCDL 20.0 7.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.25 1.25 YES FBC2020/TPI2014 CSI. TC BC WB Matrix-SH 0.87 0.83 0.47 DEFL. Vert(LL) Vert(CT) Horz(CT) in -0.22 -0.38 0.05 (loc) 12-13 12-13 9 l/defl >999 >951 n/a L/d 240 180 n/a PLATES MT20 Weight: 181 lb FT = 20% GRIP 244/190 LUMBER- TOP CHORD 2x4 SP No.2 BOT CHORD 2x4 SP No.2 WEBS 2x4 SP No.3 BRACING- TOP CHORD Structural wood sheathing directly applied. BOT CHORD Rigid ceiling directly applied or 5-7-15 oc bracing. REACTIONS. (size)2=0-8-0, 16=0-8-0, 9=0-8-0 Max Horz 2=-162(LC 10) Max Uplift 2=-239(LC 24), 16=-542(LC 12), 9=-411(LC 12) Max Grav 2=5(LC 9), 16=1951(LC 17), 9=1246(LC 18) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 2-3=-392/1161, 3-4=-1070/479, 4-5=-1548/671, 5-6=-1739/784, 6-8=-1849/742, 8-9=-2400/791 BOT CHORD 2-16=-1009/421, 13-15=-251/995, 12-13=-332/1259, 11-12=-622/1900, 9-11=-626/2119 WEBS 3-16=-1952/794, 3-15=-326/1122, 4-15=-421/198, 4-13=-300/901, 5-13=-848/450, 6-13=-255/613, 6-12=-232/814, 8-12=-519/309, 8-11=-6/320 NOTES-(8) 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-16; Vult=165mph (3-second gust) Vasd=128mph; TCDL=4.2psf; BCDL=3.0psf; h=15ft; B=45ft; L=28ft; eave=5ft; Cat. II; Exp B; Encl., GCpi=0.18; MWFRS (directional) and C-C Exterior(2E) -1-0-0 to 2-0-0, Interior(1) 2-0-0 to 11-0-0, Exterior(2R) 11-0-0 to 14-0-0, Interior(1) 14-0-0 to 19-10-0, Exterior(2R) 19-10-0 to 22-10-0, Interior(1) 22-10-0 to 36-0-0 zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) Building Designer / Project engineer responsible for verifying applied roof live load shown covers rain loading requirements specific to the use of this truss component. 4) Provide adequate drainage to prevent water ponding. 5) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 6) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members, with BCDL = 10.0psf. 7) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 239 lb uplift at joint 2, 542 lb uplift at joint 16 and 411 lb uplift at joint 9. 8) "This manufactured product is designed as an individual building component. The suitability and use of this component for any particular building is the responsibility of the building designer per ANSI TPI 1 as referenced by the building code." This item has been electronically signed and sealed by Velez, Joaquin, PE using a Digital Signature. Printed copies of this document are not considered signed and sealed and the signature must be verified on any electronic copies. April 9,2021 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component available from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 5/19/2020 BEFORE USE. 6904 Parke East Blvd. Tampa, FL 36610 Job WS0024 Truss T12 Truss Type Roof Special Qty 1 Ply 1 Job Reference (optional) T23501829 8.430 s Mar 22 2021 MiTek Industries, Inc. Thu Apr 8 08:14:55 2021 Page 1 Builders FirstSource (Tampa, FL), Tampa, FL - 33564, ID:JbsSUYEphcZuYTshvwE3BRyhOBX-fnI59A8JDG06BA_kdybVbcrM7KNXxL1I5Zk3fyzSqyk Scale = 1:64.8 1 2 3 4 5 6 7 8 9 10 16 15 14 13 12 11 17 18 19 20 21 22 23 24 4x6 ST1.5x8 STP ST1.5x8 STP ST1.5x8 STP 4x12 4x6 3x6 3x4 3x6 3x4 3x4 3x8 3x4 5x6 3x4 3x6 2x4 5-0-0 5-0-0 13-0-0 8-0-0 17-8-0 4-8-0 23-4-5 5-8-5 29-4-11 6-0-6 35-0-0 5-7-5 -1-0-0 1-0-0 7-9-7 7-9-7 13-0-0 5-2-9 17-8-0 4-8-0 19-10-0 2-2-0 26-0-0 6-2-0 35-0-0 9-0-0 36-0-0 1-0-0 0-4-15-9-16-7-140-4-15-9-15.00 12 Plate Offsets (X,Y)-- [2:0-0-14,Edge], [9:0-0-10,Edge], [12:0-3-0,0-3-0] LOADING (psf) TCLL TCDL BCLL BCDL 20.0 7.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.25 1.25 YES FBC2020/TPI2014 CSI. TC BC WB Matrix-SH 0.88 0.84 0.77 DEFL. Vert(LL) Vert(CT) Horz(CT) in -0.14 -0.24 0.06 (loc) 12-13 12-13 9 l/defl >999 >999 n/a L/d 240 180 n/a PLATES MT20 Weight: 186 lb FT = 20% GRIP 244/190 LUMBER- TOP CHORD 2x4 SP No.2 BOT CHORD 2x4 SP No.2 WEBS 2x4 SP No.3 BRACING- TOP CHORD Structural wood sheathing directly applied. BOT CHORD Rigid ceiling directly applied or 6-0-0 oc bracing. REACTIONS. (size)2=0-8-0, 16=0-8-0, 9=0-8-0 Max Horz 2=162(LC 11) Max Uplift 2=-177(LC 24), 16=-498(LC 12), 9=-417(LC 12) Max Grav 2=17(LC 21), 16=1832(LC 17), 9=1259(LC 18) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 2-3=-311/952, 3-4=-1278/566, 4-5=-1137/551, 5-6=-1620/766, 6-8=-1868/771, 8-9=-2444/817 BOT CHORD 2-16=-824/364, 14-16=-213/647, 13-14=-432/1485, 12-13=-356/1292, 11-12=-647/1923, 9-11=-650/2158 WEBS 3-16=-2026/831, 3-14=-128/726, 4-14=-43/288, 5-14=-571/207, 5-13=-420/263, 6-13=-260/596, 6-12=-236/762, 8-12=-529/308, 8-11=-4/345 NOTES-(8) 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-16; Vult=165mph (3-second gust) Vasd=128mph; TCDL=4.2psf; BCDL=3.0psf; h=15ft; B=45ft; L=28ft; eave=5ft; Cat. II; Exp B; Encl., GCpi=0.18; MWFRS (directional) and C-C Exterior(2E) -1-0-0 to 2-0-0, Interior(1) 2-0-0 to 13-0-0, Exterior(2R) 13-0-0 to 16-0-0, Interior(1) 16-0-0 to 19-10-0, Exterior(2R) 19-10-0 to 22-10-0, Interior(1) 22-10-0 to 36-0-0 zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) Building Designer / Project engineer responsible for verifying applied roof live load shown covers rain loading requirements specific to the use of this truss component. 4) Provide adequate drainage to prevent water ponding. 5) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 6) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members, with BCDL = 10.0psf. 7) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 177 lb uplift at joint 2, 498 lb uplift at joint 16 and 417 lb uplift at joint 9. 8) "This manufactured product is designed as an individual building component. The suitability and use of this component for any particular building is the responsibility of the building designer per ANSI TPI 1 as referenced by the building code." This item has been electronically signed and sealed by Velez, Joaquin, PE using a Digital Signature. Printed copies of this document are not considered signed and sealed and the signature must be verified on any electronic copies. April 9,2021 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component available from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 5/19/2020 BEFORE USE. 6904 Parke East Blvd. Tampa, FL 36610 Job WS0024 Truss T13 Truss Type Roof Special Qty 1 Ply 1 Job Reference (optional) T23501830 8.430 s Mar 22 2021 MiTek Industries, Inc. Thu Apr 8 08:14:56 2021 Page 1 Builders FirstSource (Tampa, FL), Tampa, FL - 33564, ID:JbsSUYEphcZuYTshvwE3BRyhOBX-7zsTMW9y_a8zpJZwBg6k8pNY6kkYgwtRKDUcBPzSqyj Scale = 1:64.8 1 2 3 4 5 6 7 8 9 10 16 15 14 13 12 11 17 18 19 20 21 22 3x6 ST1.5x8 STP ST1.5x8 STP 5x8 4x6 3x6 3x6 4x6 3x4 2x4 3x4 3x4 2x4 4x6 3x6 3x8 7-4-11 7-4-11 15-0-0 7-7-5 19-8-0 4-8-0 20-0-0 0-4-0 27-7-6 7-7-6 35-0-0 7-4-10 -1-0-0 1-0-0 7-4-11 7-4-11 15-0-0 7-7-5 19-8-0 4-8-0 19-10-0 0-2-0 20-0-0 0-2-0 27-7-6 7-7-6 35-0-0 7-4-10 36-0-0 1-0-0 0-4-16-7-10-4-16-7-15.00 12 Plate Offsets (X,Y)-- [5:0-5-12,0-2-8] LOADING (psf) TCLL TCDL BCLL BCDL 20.0 7.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.25 1.25 YES FBC2020/TPI2014 CSI. TC BC WB Matrix-SH 0.80 0.79 0.29 DEFL. Vert(LL) Vert(CT) Horz(CT) in -0.17 -0.37 0.13 (loc) 14 14-16 9 l/defl >999 >999 n/a L/d 240 180 n/a PLATES MT20 Weight: 173 lb FT = 20% GRIP 244/190 LUMBER- TOP CHORD 2x4 SP No.2 BOT CHORD 2x4 SP No.2 WEBS 2x4 SP No.3 BRACING- TOP CHORD Structural wood sheathing directly applied. BOT CHORD Rigid ceiling directly applied or 6-2-4 oc bracing. WEBS 1 Row at midpt 3-14, 8-13 REACTIONS. (size)2=0-8-0, 9=0-8-0 Max Horz 2=-160(LC 10) Max Uplift 2=-483(LC 12), 9=-483(LC 12) Max Grav 2=1342(LC 1), 9=1342(LC 1) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 2-3=-2686/1052, 3-5=-1940/845, 5-6=-1719/842, 6-8=-1941/845, 8-9=-2686/1052 BOT CHORD 2-16=-880/2398, 14-16=-880/2398, 13-14=-553/1718, 11-13=-884/2398, 9-11=-884/2398 WEBS 3-16=0/327, 3-14=-751/354, 5-14=-95/441, 8-11=0/327, 6-13=-104/442, 8-13=-751/354 NOTES-(8) 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-16; Vult=165mph (3-second gust) Vasd=128mph; TCDL=4.2psf; BCDL=3.0psf; h=15ft; B=45ft; L=28ft; eave=5ft; Cat. II; Exp B; Encl., GCpi=0.18; MWFRS (directional) and C-C Exterior(2E) -1-0-0 to 2-0-0, Interior(1) 2-0-0 to 15-0-0, Exterior(2R) 15-0-0 to 18-0-0, Interior(1) 18-0-0 to 20-0-0, Exterior(2R) 20-0-0 to 23-0-0, Interior(1) 23-0-0 to 36-0-0 zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) Building Designer / Project engineer responsible for verifying applied roof live load shown covers rain loading requirements specific to the use of this truss component. 4) Provide adequate drainage to prevent water ponding. 5) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 6) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 7) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 483 lb uplift at joint 2 and 483 lb uplift at joint 9. 8) "This manufactured product is designed as an individual building component. The suitability and use of this component for any particular building is the responsibility of the building designer per ANSI TPI 1 as referenced by the building code." This item has been electronically signed and sealed by Velez, Joaquin, PE using a Digital Signature. Printed copies of this document are not considered signed and sealed and the signature must be verified on any electronic copies. April 9,2021 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component available from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 5/19/2020 BEFORE USE. 6904 Parke East Blvd. Tampa, FL 36610 Job WS0024 Truss T14 Truss Type Hip Qty 1 Ply 1 Job Reference (optional) T23501831 8.430 s Mar 22 2021 MiTek Industries, Inc. Thu Apr 8 08:14:57 2021 Page 1 Builders FirstSource (Tampa, FL), Tampa, FL - 33564, ID:JbsSUYEphcZuYTshvwE3BRyhOBX-c9QrZs9altGpRT86lNdzg1wog85bPGbbZtDAjrzSqyi Scale = 1:64.8 1 2 3 4 5 6 7 8 9 10 11 12 13 18 17 16 15 14 19 20 21 22 23 24 3x6 ST1.5x8 STP ST1.5x8 STP 3x6 3x6 3x6 3x6 4x6 3x4 2x4 3x4 3x8 3x4 3x4 2x4 4x6 3x6 3x6 8-9-9 8-9-9 17-0-0 8-2-7 17-6-0 0-6-0 18-0-0 0-6-0 26-2-7 8-2-7 35-0-0 8-9-9 -1-0-0 1-0-0 6-1-3 6-1-3 12-3-13 6-2-10 17-0-0 4-8-3 17-6-0 0-6-0 18-0-0 0-6-0 22-8-3 4-8-3 28-10-13 6-2-10 35-0-0 6-1-3 36-0-0 1-0-0 0-4-17-5-10-4-17-5-15.00 12 Plate Offsets (X,Y)-- [6:0-3-0,0-2-4], [8:0-3-0,0-2-4] LOADING (psf) TCLL TCDL BCLL BCDL 20.0 7.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.25 1.25 YES FBC2020/TPI2014 CSI. TC BC WB Matrix-SH 0.49 0.73 0.70 DEFL. Vert(LL) Vert(CT) Horz(CT) in -0.26 -0.45 0.12 (loc) 14-16 14-16 12 l/defl >999 >909 n/a L/d 240 180 n/a PLATES MT20 Weight: 171 lb FT = 20% GRIP 244/190 LUMBER- TOP CHORD 2x4 SP No.2 BOT CHORD 2x4 SP No.1 WEBS 2x4 SP No.3 BRACING- TOP CHORD Structural wood sheathing directly applied or 2-11-13 oc purlins. BOT CHORD Rigid ceiling directly applied or 6-10-2 oc bracing. REACTIONS. (size)2=0-8-0, 12=0-8-0 Max Horz 2=-180(LC 10) Max Uplift 2=-483(LC 12), 12=-483(LC 12) Max Grav 2=1492(LC 17), 12=1492(LC 18) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 2-3=-2945/999, 3-5=-2734/929, 5-6=-1883/734, 6-7=-1696/704, 7-8=-1696/704, 8-9=-1883/734, 9-11=-2735/929, 11-12=-2946/999 BOT CHORD 2-18=-832/2789, 16-18=-608/2218, 14-16=-618/2123, 12-14=-842/2654 WEBS 3-18=-297/215, 5-18=-113/637, 5-16=-689/320, 9-16=-689/320, 9-14=-113/637, 11-14=-297/215, 7-16=-381/1191 NOTES-(8) 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-16; Vult=165mph (3-second gust) Vasd=128mph; TCDL=4.2psf; BCDL=3.0psf; h=15ft; B=45ft; L=28ft; eave=5ft; Cat. II; Exp B; Encl., GCpi=0.18; MWFRS (directional) and C-C Exterior(2E) -1-0-0 to 2-0-0, Interior(1) 2-0-0 to 17-0-0, Exterior(2E) 17-0-0 to 18-0-0, Exterior(2R) 18-0-0 to 22-2-15, Interior(1) 22-2-15 to 36-0-0 zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) Building Designer / Project engineer responsible for verifying applied roof live load shown covers rain loading requirements specific to the use of this truss component. 4) Provide adequate drainage to prevent water ponding. 5) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 6) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members, with BCDL = 10.0psf. 7) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 483 lb uplift at joint 2 and 483 lb uplift at joint 12. 8) "This manufactured product is designed as an individual building component. The suitability and use of this component for any particular building is the responsibility of the building designer per ANSI TPI 1 as referenced by the building code." This item has been electronically signed and sealed by Velez, Joaquin, PE using a Digital Signature. Printed copies of this document are not considered signed and sealed and the signature must be verified on any electronic copies. April 9,2021 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component available from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 5/19/2020 BEFORE USE. 6904 Parke East Blvd. Tampa, FL 36610 Job WS0024 Truss T14A Truss Type Hip Qty 1 Ply 1 Job Reference (optional) T23501832 8.430 s Mar 22 2021 MiTek Industries, Inc. Thu Apr 8 08:14:58 2021 Page 1 Builders FirstSource (Tampa, FL), Tampa, FL - 33564, ID:JbsSUYEphcZuYTshvwE3BRyhOBX-4M_EnCACWBOg2djJJ58CDETw_YQs8faknXzjGHzSqyh Scale = 1:66.0 1 2 3 4 5 6 7 8 9 10 11 12 13 15 14 18 17 16 21 20 19 22 23 24 25 3x6 ST1.5x8 STP ST1.5x8 STP 4x6 4x6 3x6 3x4 2x4 3x8 2x4 4x10 MT20HS 2x4 2x4 3x6 3x4 5x6 5x8 3x4 5x8 3x4 3x6 7-2-10 7-2-10 11-3-4 4-0-10 17-0-0 5-8-12 20-8-0 3-8-0 27-1-12 6-5-12 35-0-0 7-10-4 -1-0-0 1-0-0 4-10-13 4-10-13 11-3-4 6-4-7 17-0-0 5-8-12 18-0-0 1-0-0 20-8-0 2-8-0 23-5-6 2-9-6 27-1-12 3-8-5 29-1-10 1-11-14 35-0-0 5-10-6 36-0-0 1-0-0 0-4-17-5-10-4-12-0-07-5-15.00 12 Plate Offsets (X,Y)-- [16:0-5-8,0-3-8], [18:0-5-8,0-3-4], [20:0-2-12,0-3-0] LOADING (psf) TCLL TCDL BCLL BCDL 20.0 7.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.25 1.25 YES FBC2020/TPI2014 CSI. TC BC WB Matrix-SH 0.58 0.80 0.91 DEFL. Vert(LL) Vert(CT) Horz(CT) in -0.23 -0.45 0.19 (loc) 18 19-20 12 l/defl >999 >925 n/a L/d 240 180 n/a PLATES MT20 MT20HS Weight: 209 lb FT = 20% GRIP 244/190 187/143 LUMBER- TOP CHORD 2x4 SP No.2 BOT CHORD 2x4 SP No.2 WEBS 2x4 SP No.3 BRACING- TOP CHORD Structural wood sheathing directly applied or 2-9-1 oc purlins. BOT CHORD Rigid ceiling directly applied or 6-4-12 oc bracing. REACTIONS. (size)12=0-8-0, 2=0-8-0 Max Horz 2=180(LC 11) Max Uplift 12=-483(LC 12), 2=-483(LC 12) Max Grav 12=1342(LC 1), 2=1342(LC 1) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 2-3=-2704/1019, 3-5=-2509/955, 5-6=-2365/917, 6-7=-2145/886, 7-8=-2341/939, 8-10=-2988/1112, 10-11=-2507/957, 11-12=-2664/980 BOT CHORD 12-14=-823/2378, 17-18=-573/2140, 16-17=-823/2711, 2-21=-861/2436, 20-21=-643/2034 WEBS 5-21=-110/351, 6-18=-244/741, 8-16=-215/749, 5-20=-608/258, 18-20=-678/2144, 10-14=-499/219, 14-16=-789/2396, 10-16=-63/436, 7-17=-336/814, 8-17=-983/431 NOTES-(9) 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-16; Vult=165mph (3-second gust) Vasd=128mph; TCDL=4.2psf; BCDL=3.0psf; h=15ft; B=45ft; L=28ft; eave=5ft; Cat. II; Exp B; Encl., GCpi=0.18; MWFRS (directional) and C-C Exterior(2E) -1-0-0 to 2-0-0, Interior(1) 2-0-0 to 17-0-0, Exterior(2E) 17-0-0 to 18-0-0, Exterior(2R) 18-0-0 to 22-2-15, Interior(1) 22-2-15 to 36-0-0 zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) Building Designer / Project engineer responsible for verifying applied roof live load shown covers rain loading requirements specific to the use of this truss component. 4) Provide adequate drainage to prevent water ponding. 5) All plates are MT20 plates unless otherwise indicated. 6) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 7) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 8) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 483 lb uplift at joint 12 and 483 lb uplift at joint 2. 9) "This manufactured product is designed as an individual building component. The suitability and use of this component for any particular building is the responsibility of the building designer per ANSI TPI 1 as referenced by the building code." This item has been electronically signed and sealed by Velez, Joaquin, PE using a Digital Signature. Printed copies of this document are not considered signed and sealed and the signature must be verified on any electronic copies. April 9,2021 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component available from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 5/19/2020 BEFORE USE. 6904 Parke East Blvd. Tampa, FL 36610 Job WS0024 Truss T15 Truss Type Hip Qty 10 Ply 1 Job Reference (optional) T23501833 8.430 s Mar 22 2021 MiTek Industries, Inc. Thu Apr 8 08:14:59 2021 Page 1 Builders FirstSource (Tampa, FL), Tampa, FL - 33564, ID:JbsSUYEphcZuYTshvwE3BRyhOBX-YYXc_YBqGVWXgnIVsogRlS?79xn3t9xu0BiGokzSqyg Scale = 1:62.4 1 2 3 4 5 6 7 8 9 10 11 16 15 14 13 12 17 18 19 20 21 22 3x6 ST1.5x8 STP ST1.5x8 STP 4x6 3x6 3x6 4x6 3x4 2x4 3x4 3x8 3x4 3x4 2x4 4x6 3x6 8-9-9 8-9-9 17-0-0 8-2-7 17-6-0 0-6-0 18-0-0 0-6-0 26-2-7 8-2-7 35-0-0 8-9-9 -1-0-0 1-0-0 6-1-3 6-1-3 12-3-13 6-2-10 17-0-0 4-8-3 17-6-0 0-6-0 18-0-0 0-6-0 22-8-3 4-8-3 28-10-13 6-2-10 35-0-0 6-1-3 36-0-0 1-0-0 0-4-17-7-90-4-15.00 12 LOADING (psf) TCLL TCDL BCLL BCDL 20.0 7.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.25 1.25 YES FBC2020/TPI2014 CSI. TC BC WB Matrix-SH 0.49 0.73 0.71 DEFL. Vert(LL) Vert(CT) Horz(CT) in -0.26 -0.45 0.12 (loc) 12-14 12-14 10 l/defl >999 >914 n/a L/d 240 180 n/a PLATES MT20 Weight: 172 lb FT = 20% GRIP 244/190 LUMBER- TOP CHORD 2x4 SP No.2 BOT CHORD 2x4 SP No.1 WEBS 2x4 SP No.3 BRACING- TOP CHORD Structural wood sheathing directly applied or 2-11-9 oc purlins. BOT CHORD Rigid ceiling directly applied or 6-10-1 oc bracing. REACTIONS. (size)2=0-8-0, 10=0-8-0 Max Horz 2=-185(LC 10) Max Uplift 2=-483(LC 12), 10=-483(LC 12) Max Grav 2=1490(LC 17), 10=1490(LC 18) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 2-3=-2940/1003, 3-5=-2730/934, 5-6=-1881/747, 6-7=-1881/747, 7-9=-2731/934, 9-10=-2940/1003 BOT CHORD 2-16=-839/2787, 14-16=-619/2220, 12-14=-623/2126, 10-12=-844/2649 WEBS 3-16=-295/212, 5-16=-110/634, 5-14=-699/323, 7-14=-699/323, 7-12=-110/634, 9-12=-295/212, 6-14=-388/1205 NOTES-(7) 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-16; Vult=165mph (3-second gust) Vasd=128mph; TCDL=4.2psf; BCDL=3.0psf; h=15ft; B=45ft; L=28ft; eave=5ft; Cat. II; Exp B; Encl., GCpi=0.18; MWFRS (directional) and C-C Exterior(2E) -1-0-0 to 2-0-0, Interior(1) 2-0-0 to 17-6-0, Exterior(2R) 17-6-0 to 20-6-0, Interior(1) 20-6-0 to 36-0-0 zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) Building Designer / Project engineer responsible for verifying applied roof live load shown covers rain loading requirements specific to the use of this truss component. 4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 5) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members, with BCDL = 10.0psf. 6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 483 lb uplift at joint 2 and 483 lb uplift at joint 10. 7) "This manufactured product is designed as an individual building component. The suitability and use of this component for any particular building is the responsibility of the building designer per ANSI TPI 1 as referenced by the building code." This item has been electronically signed and sealed by Velez, Joaquin, PE using a Digital Signature. Printed copies of this document are not considered signed and sealed and the signature must be verified on any electronic copies. April 9,2021 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component available from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 5/19/2020 BEFORE USE. 6904 Parke East Blvd. Tampa, FL 36610 Job WS0024 Truss T16 Truss Type Hip Qty 1 Ply 1 Job Reference (optional) T23501834 8.430 s Mar 22 2021 MiTek Industries, Inc. Thu Apr 8 08:15:00 2021 Page 1 Builders FirstSource (Tampa, FL), Tampa, FL - 33564, ID:JbsSUYEphcZuYTshvwE3BRyhOBX-0k5_CuCS1oeOIxshQVBgIfYD5L6Ucjt1FrSqKAzSqyf Scale = 1:64.8 1 2 3 4 5 6 7 8 9 10 16 15 14 13 12 11 17 18 19 20 21 22 3x6 ST1.5x8 STP ST1.5x8 STP 5x8 4x6 3x6 3x6 4x6 3x4 2x4 3x4 3x8 3x4 2x4 4x6 3x6 7-4-11 7-4-11 15-0-0 7-7-5 20-0-0 5-0-0 27-7-5 7-7-5 35-0-0 7-4-11 -1-0-0 1-0-0 7-4-11 7-4-11 15-0-0 7-7-5 20-0-0 5-0-0 27-7-5 7-7-5 35-0-0 7-4-11 36-0-0 1-0-0 0-4-16-7-10-4-16-7-15.00 12 Plate Offsets (X,Y)-- [5:0-5-12,0-2-8] LOADING (psf) TCLL TCDL BCLL BCDL 20.0 7.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.25 1.25 YES FBC2020/TPI2014 CSI. TC BC WB Matrix-SH 0.80 0.79 0.29 DEFL. Vert(LL) Vert(CT) Horz(CT) in -0.17 -0.37 0.13 (loc) 14 14-16 9 l/defl >999 >999 n/a L/d 240 180 n/a PLATES MT20 Weight: 173 lb FT = 20% GRIP 244/190 LUMBER- TOP CHORD 2x4 SP No.2 BOT CHORD 2x4 SP No.2 WEBS 2x4 SP No.3 BRACING- TOP CHORD Structural wood sheathing directly applied. BOT CHORD Rigid ceiling directly applied or 6-3-8 oc bracing. WEBS 1 Row at midpt 3-14, 8-13 REACTIONS. (size)2=0-8-0, 9=0-8-0 Max Horz 2=160(LC 11) Max Uplift 2=-483(LC 12), 9=-483(LC 12) Max Grav 2=1342(LC 1), 9=1342(LC 1) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 2-3=-2686/1019, 3-5=-1940/809, 5-6=-1719/804, 6-8=-1941/809, 8-9=-2686/1019 BOT CHORD 2-16=-844/2398, 14-16=-844/2398, 13-14=-516/1718, 11-13=-854/2398, 9-11=-854/2398 WEBS 3-16=0/327, 3-14=-751/356, 5-14=-96/441, 6-13=-103/442, 8-13=-751/356, 8-11=0/327 NOTES-(8) 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-16; Vult=165mph (3-second gust) Vasd=128mph; TCDL=4.2psf; BCDL=3.0psf; h=15ft; B=45ft; L=28ft; eave=5ft; Cat. II; Exp B; Encl., GCpi=0.18; MWFRS (directional) and C-C Exterior(2E) -1-0-0 to 2-0-0, Interior(1) 2-0-0 to 15-0-0, Exterior(2R) 15-0-0 to 19-2-15, Interior(1) 19-2-15 to 20-0-0, Exterior(2R) 20-0-0 to 24-2-15, Interior(1) 24-2-15 to 36-0-0 zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) Building Designer / Project engineer responsible for verifying applied roof live load shown covers rain loading requirements specific to the use of this truss component. 4) Provide adequate drainage to prevent water ponding. 5) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 6) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 7) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 483 lb uplift at joint 2 and 483 lb uplift at joint 9. 8) "This manufactured product is designed as an individual building component. The suitability and use of this component for any particular building is the responsibility of the building designer per ANSI TPI 1 as referenced by the building code." This item has been electronically signed and sealed by Velez, Joaquin, PE using a Digital Signature. Printed copies of this document are not considered signed and sealed and the signature must be verified on any electronic copies. April 9,2021 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component available from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 5/19/2020 BEFORE USE. 6904 Parke East Blvd. Tampa, FL 36610 Job WS0024 Truss T17 Truss Type Hip Qty 1 Ply 1 Job Reference (optional) T23501835 8.430 s Mar 22 2021 MiTek Industries, Inc. Thu Apr 8 08:15:01 2021 Page 1 Builders FirstSource (Tampa, FL), Tampa, FL - 33564, ID:JbsSUYEphcZuYTshvwE3BRyhOBX-UxfMPDC4o6mFv5Ru_Divrt5N?lOQL7oBUVBNsczSqye Scale: 3/16"=1' 1 2 3 4 5 6 7 8 9 15 14 13 12 11 10 16 17 18 19 20 21 22 23 4x6 ST1.5x8 STP ST1.5x8 STP 4x6 3x6 4x6 3x4 2x4 3x8 3x4 3x8 3x4 2x4 4x6 3x6 7-7-12 7-7-12 13-0-0 5-4-4 22-0-0 9-0-0 27-4-4 5-4-4 35-0-0 7-7-12 -1-0-0 1-0-0 7-7-12 7-7-12 13-0-0 5-4-4 17-6-0 4-6-0 22-0-0 4-6-0 27-4-4 5-4-4 35-0-0 7-7-12 36-0-0 1-0-0 0-4-15-9-10-4-15-9-15.00 12 LOADING (psf) TCLL TCDL BCLL BCDL 20.0 7.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.25 1.25 YES FBC2020/TPI2014 CSI. TC BC WB Matrix-SH 0.85 1.00 0.50 DEFL. Vert(LL) Vert(CT) Horz(CT) in -0.35 -0.62 0.14 (loc) 12-13 12-13 8 l/defl >999 >664 n/a L/d 240 180 n/a PLATES MT20 Weight: 173 lb FT = 20% GRIP 244/190 LUMBER- TOP CHORD 2x4 SP No.2 BOT CHORD 2x4 SP No.2 WEBS 2x4 SP No.3 BRACING- TOP CHORD Structural wood sheathing directly applied or 2-2-0 oc purlins. BOT CHORD Rigid ceiling directly applied or 2-2-0 oc bracing. REACTIONS. (size)2=0-8-0, 8=0-8-0 Max Horz 2=-140(LC 10) Max Uplift 2=-483(LC 12), 8=-483(LC 12) Max Grav 2=1490(LC 17), 8=1490(LC 18) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 2-3=-2916/1008, 3-4=-2307/862, 4-5=-2102/837, 5-6=-2102/837, 6-7=-2307/862, 7-8=-2916/1008 BOT CHORD 2-15=-826/2709, 13-15=-826/2709, 12-13=-654/2209, 10-12=-837/2605, 8-10=-837/2605 WEBS 3-15=0/252, 3-13=-654/290, 4-13=-178/682, 5-13=-293/119, 5-12=-293/119, 6-12=-178/682, 7-12=-655/290, 7-10=0/252 NOTES-(8) 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-16; Vult=165mph (3-second gust) Vasd=128mph; TCDL=4.2psf; BCDL=3.0psf; h=15ft; B=45ft; L=28ft; eave=5ft; Cat. II; Exp B; Encl., GCpi=0.18; MWFRS (directional) and C-C Exterior(2E) -1-0-0 to 2-0-0, Interior(1) 2-0-0 to 13-0-0, Exterior(2R) 13-0-0 to 17-6-0, Interior(1) 17-6-0 to 22-0-0, Exterior(2R) 22-0-0 to 26-2-15, Interior(1) 26-2-15 to 36-0-0 zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) Building Designer / Project engineer responsible for verifying applied roof live load shown covers rain loading requirements specific to the use of this truss component. 4) Provide adequate drainage to prevent water ponding. 5) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 6) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members, with BCDL = 10.0psf. 7) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 483 lb uplift at joint 2 and 483 lb uplift at joint 8. 8) "This manufactured product is designed as an individual building component. The suitability and use of this component for any particular building is the responsibility of the building designer per ANSI TPI 1 as referenced by the building code." This item has been electronically signed and sealed by Velez, Joaquin, PE using a Digital Signature. Printed copies of this document are not considered signed and sealed and the signature must be verified on any electronic copies. April 9,2021 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component available from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 5/19/2020 BEFORE USE. 6904 Parke East Blvd. Tampa, FL 36610 Job WS0024 Truss T18 Truss Type Hip Qty 1 Ply 1 Job Reference (optional) T23501836 8.430 s Mar 22 2021 MiTek Industries, Inc. Thu Apr 8 08:15:02 2021 Page 1 Builders FirstSource (Tampa, FL), Tampa, FL - 33564, ID:JbsSUYEphcZuYTshvwE3BRyhOBX-y7DkdZDiZQu6XE04YwD8N4dc_9of4e5Ki9xxP2zSqyd Scale: 3/16"=1' 1 2 3 4 5 6 7 8 9 16 15 14 13 12 11 10 17 18 19 20 21 22 5x8 ST1.5x8 STP ST1.5x8 STP 5x8 3x6 3x6 3x4 2x4 3x4 3x8 2x4 3x4 3x4 2x4 3x6 3x6 6-6-5 6-6-5 11-0-0 4-5-11 17-6-0 6-6-0 24-0-0 6-6-0 28-5-11 4-5-11 35-0-0 6-6-5 -1-0-0 1-0-0 6-6-5 6-6-5 11-0-0 4-5-11 17-6-0 6-6-0 24-0-0 6-6-0 28-5-11 4-5-11 35-0-0 6-6-5 36-0-0 1-0-0 0-4-14-11-10-4-14-11-15.00 12 Plate Offsets (X,Y)-- [4:0-5-12,0-2-8], [6:0-5-12,0-2-8] LOADING (psf) TCLL TCDL BCLL BCDL 20.0 7.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.25 1.25 YES FBC2020/TPI2014 CSI. TC BC WB Matrix-SH 0.58 0.74 0.24 DEFL. Vert(LL) Vert(CT) Horz(CT) in -0.20 -0.38 0.13 (loc) 13 13-15 8 l/defl >999 >999 n/a L/d 240 180 n/a PLATES MT20 Weight: 174 lb FT = 20% GRIP 244/190 LUMBER- TOP CHORD 2x4 SP No.2 BOT CHORD 2x4 SP No.2 WEBS 2x4 SP No.3 BRACING- TOP CHORD Structural wood sheathing directly applied or 2-10-9 oc purlins. BOT CHORD Rigid ceiling directly applied or 6-3-8 oc bracing. REACTIONS. (size)2=0-8-0, 8=0-8-0 Max Horz 2=-120(LC 10) Max Uplift 2=-483(LC 12), 8=-483(LC 12) Max Grav 2=1342(LC 1), 8=1342(LC 1) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 2-3=-2681/1020, 3-4=-2249/910, 4-5=-2410/1014, 5-6=-2410/1014, 6-7=-2249/910, 7-8=-2681/1020 BOT CHORD 2-16=-847/2391, 15-16=-847/2391, 13-15=-653/2037, 11-13=-662/2037, 10-11=-857/2391, 8-10=-857/2391 WEBS 3-15=-434/229, 4-15=-86/369, 4-13=-183/574, 5-13=-401/247, 6-13=-183/574, 6-11=-86/369, 7-11=-434/229 NOTES-(8) 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-16; Vult=165mph (3-second gust) Vasd=128mph; TCDL=4.2psf; BCDL=3.0psf; h=15ft; B=45ft; L=28ft; eave=5ft; Cat. II; Exp B; Encl., GCpi=0.18; MWFRS (directional) and C-C Exterior(2E) -1-0-0 to 2-0-0, Interior(1) 2-0-0 to 11-0-0, Exterior(2R) 11-0-0 to 15-2-15, Interior(1) 15-2-15 to 24-0-0, Exterior(2R) 24-0-0 to 28-5-11, Interior(1) 28-5-11 to 36-0-0 zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) Building Designer / Project engineer responsible for verifying applied roof live load shown covers rain loading requirements specific to the use of this truss component. 4) Provide adequate drainage to prevent water ponding. 5) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 6) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 7) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 483 lb uplift at joint 2 and 483 lb uplift at joint 8. 8) "This manufactured product is designed as an individual building component. The suitability and use of this component for any particular building is the responsibility of the building designer per ANSI TPI 1 as referenced by the building code." This item has been electronically signed and sealed by Velez, Joaquin, PE using a Digital Signature. Printed copies of this document are not considered signed and sealed and the signature must be verified on any electronic copies. April 9,2021 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component available from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 5/19/2020 BEFORE USE. 6904 Parke East Blvd. Tampa, FL 36610 Job WS0024 Truss T19 Truss Type Hip Qty 1 Ply 1 Job Reference (optional) T23501837 8.430 s Mar 22 2021 MiTek Industries, Inc. Thu Apr 8 08:15:03 2021 Page 1 Builders FirstSource (Tampa, FL), Tampa, FL - 33564, ID:JbsSUYEphcZuYTshvwE3BRyhOBX-QJn6qvELKj0z9ObG5ekNwIAiUZ5rp1QTxpgUxVzSqyc Scale: 3/16"=1' 1 2 3 4 5 6 7 8 9 10 11 16 15 14 13 12 17 18 19 20 21 22 4x6 ST1.5x8 STP ST1.5x8 STP 3x6 4x6 3x6 4x6 3x8 2x4 3x4 3x4 3x4 3x8 2x4 4x6 3x6 9-0-0 9-0-0 17-6-0 8-6-0 26-0-0 8-6-0 35-0-0 9-0-0 -1-0-0 1-0-0 5-8-11 5-8-11 9-0-0 3-3-5 13-4-12 4-4-12 21-7-4 8-2-8 26-0-0 4-4-12 29-3-5 3-3-5 35-0-0 5-8-11 36-0-0 1-0-0 0-4-14-1-10-4-14-1-15.00 12 LOADING (psf) TCLL TCDL BCLL BCDL 20.0 7.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.25 1.25 YES FBC2020/TPI2014 CSI. TC BC WB Matrix-SH 0.92 0.94 0.49 DEFL. Vert(LL) Vert(CT) Horz(CT) in -0.24 -0.47 0.14 (loc) 14 14-16 10 l/defl >999 >881 n/a L/d 240 180 n/a PLATES MT20 Weight: 164 lb FT = 20% GRIP 244/190 LUMBER- TOP CHORD 2x4 SP No.2 BOT CHORD 2x4 SP No.2 WEBS 2x4 SP No.3 BRACING- TOP CHORD Structural wood sheathing directly applied. BOT CHORD Rigid ceiling directly applied or 2-2-0 oc bracing. REACTIONS. (size)2=0-8-0, 10=0-8-0 Max Horz 2=100(LC 11) Max Uplift 2=-483(LC 12), 10=-483(LC 12) Max Grav 2=1342(LC 1), 10=1342(LC 1) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 2-3=-2646/1035, 3-4=-2418/938, 4-5=-2219/899, 5-7=-2828/1106, 7-8=-2219/899, 8-9=-2418/938, 9-10=-2646/1035 BOT CHORD 2-16=-865/2377, 14-16=-957/2743, 12-14=-950/2743, 10-12=-875/2377 WEBS 4-16=-266/781, 5-16=-772/331, 7-12=-772/331, 8-12=-266/781 NOTES-(8) 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-16; Vult=165mph (3-second gust) Vasd=128mph; TCDL=4.2psf; BCDL=3.0psf; h=15ft; B=45ft; L=28ft; eave=5ft; Cat. II; Exp B; Encl., GCpi=0.18; MWFRS (directional) and C-C Exterior(2E) -1-0-0 to 2-0-0, Interior(1) 2-0-0 to 9-0-0, Exterior(2R) 9-0-0 to 13-4-12, Interior(1) 13-4-12 to 26-0-0, Exterior(2R) 26-0-0 to 30-2-15, Interior(1) 30-2-15 to 36-0-0 zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) Building Designer / Project engineer responsible for verifying applied roof live load shown covers rain loading requirements specific to the use of this truss component. 4) Provide adequate drainage to prevent water ponding. 5) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 6) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 7) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 483 lb uplift at joint 2 and 483 lb uplift at joint 10. 8) "This manufactured product is designed as an individual building component. The suitability and use of this component for any particular building is the responsibility of the building designer per ANSI TPI 1 as referenced by the building code." This item has been electronically signed and sealed by Velez, Joaquin, PE using a Digital Signature. Printed copies of this document are not considered signed and sealed and the signature must be verified on any electronic copies. April 9,2021 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component available from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 5/19/2020 BEFORE USE. 6904 Parke East Blvd. Tampa, FL 36610 Job WS0024 Truss T20 Truss Type HIP GIRDER Qty 1 Ply 2 Job Reference (optional) T23501838 8.430 s Mar 22 2021 MiTek Industries, Inc. Thu Apr 8 08:15:05 2021 Page 1 Builders FirstSource (Tampa, FL), Tampa, FL - 33564, ID:JbsSUYEphcZuYTshvwE3BRyhOBX-NivtFbGbsLHhOilfD3mr?jF5gMpPHvImO79b?NzSqya Scale: 3/16"=1' 1 2 3 4 5 6 7 8 9 15 14 13 12 11 10 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 5x8 ST1.5x8 STP ST1.5x8 STP 3x6 5x8 3x6 4x6 2x4 5x8 2x4 3x4 3x6 2x4 4x6 3x6 7-0-0 7-0-0 14-0-9 7-0-9 20-11-7 6-10-13 28-0-0 7-0-9 35-0-0 7-0-0 -1-0-0 1-0-0 7-0-0 7-0-0 14-0-9 7-0-9 20-11-7 6-10-13 28-0-0 7-0-9 35-0-0 7-0-0 36-0-0 1-0-0 0-4-13-3-10-4-13-3-15.00 12 Plate Offsets (X,Y)-- [3:0-5-12,0-2-8], [7:0-5-12,0-2-8] LOADING (psf) TCLL TCDL BCLL BCDL 20.0 7.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.25 1.25 NO FBC2020/TPI2014 CSI. TC BC WB Matrix-SH 0.75 0.80 0.59 DEFL. Vert(LL) Vert(CT) Horz(CT) in -0.33 -0.65 0.14 (loc) 12-13 12-13 8 l/defl >999 >637 n/a L/d 240 180 n/a PLATES MT20 Weight: 314 lb FT = 20% GRIP 244/190 LUMBER- TOP CHORD 2x4 SP No.2 *Except* 3-5,5-7: 2x4 SP M 31 BOT CHORD 2x4 SP No.1 WEBS 2x4 SP No.3 BRACING- TOP CHORD Structural wood sheathing directly applied or 4-3-1 oc purlins. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing, Except: 8-3-15 oc bracing: 12-13. REACTIONS. (size)2=0-8-0, 8=0-8-0 Max Horz 2=-80(LC 6) Max Uplift 2=-944(LC 8), 8=-960(LC 8) Max Grav 2=2608(LC 1), 8=2625(LC 1) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 2-3=-5798/1982, 3-4=-8055/2838, 4-6=-8054/2838, 6-7=-8064/2850, 7-8=-5840/2021 BOT CHORD 2-15=-1721/5235, 13-15=-1724/5264, 12-13=-2713/8064, 10-12=-1758/5302, 8-10=-1756/5274 WEBS 3-15=-46/702, 3-13=-1060/3117, 4-13=-820/507, 6-12=-825/502, 7-12=-1035/3071, 7-10=-46/703 NOTES-(11) 1) 2-ply truss to be connected together with 10d (0.131"x3") nails as follows: Top chords connected as follows: 2x4 - 1 row at 0-9-0 oc. Bottom chords connected as follows: 2x4 - 1 row at 0-9-0 oc. Webs connected as follows: 2x4 - 1 row at 0-9-0 oc. 2) All loads are considered equally applied to all plies, except if noted as front (F) or back (B) face in the LOAD CASE(S) section. Ply to ply connections have been provided to distribute only loads noted as (F) or (B), unless otherwise indicated. 3) Unbalanced roof live loads have been considered for this design. 4) Wind: ASCE 7-16; Vult=165mph (3-second gust) Vasd=128mph; TCDL=4.2psf; BCDL=3.0psf; h=15ft; B=45ft; L=28ft; eave=5ft; Cat. II; Exp B; Encl., GCpi=0.18; MWFRS (directional); cantilever left and right exposed ; end vertical left and right exposed; Lumber DOL=1.60 plate grip DOL=1.60 5) Building Designer / Project engineer responsible for verifying applied roof live load shown covers rain loading requirements specific to the use of this truss component. 6) Provide adequate drainage to prevent water ponding. 7) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 8) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 9) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 944 lb uplift at joint 2 and 960 lb uplift at joint 8. Continued on page 2 This item has been electronically signed and sealed by Velez, Joaquin, PE using a Digital Signature. Printed copies of this document are not considered signed and sealed and the signature must be verified on any electronic copies. April 9,2021 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component available from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 5/19/2020 BEFORE USE. 6904 Parke East Blvd. Tampa, FL 36610 Job WS0024 Truss T20 Truss Type HIP GIRDER Qty 1 Ply 2 Job Reference (optional) T23501838 8.430 s Mar 22 2021 MiTek Industries, Inc. Thu Apr 8 08:15:05 2021 Page 2 Builders FirstSource (Tampa, FL), Tampa, FL - 33564, ID:JbsSUYEphcZuYTshvwE3BRyhOBX-NivtFbGbsLHhOilfD3mr?jF5gMpPHvImO79b?NzSqya NOTES-(11) 10) Hanger(s) or other connection device(s) shall be provided sufficient to support concentrated load(s) 124 lb down and 122 lb up at 7-0-0, 105 lb down and 118 lb up at 9-0-12, 105 lb down and 118 lb up at 11-0-12, 105 lb down and 118 lb up at 13-0-12, 105 lb down and 118 lb up at 15-0-12, 105 lb down and 118 lb up at 17-0-12, 105 lb down and 118 lb up at 17-11-4, 105 lb down and 118 lb up at 19-11-4, 105 lb down and 118 lb up at 21-11-4, 105 lb down and 118 lb up at 23-11-4, and 105 lb down and 118 lb up at 25-11-4, and 180 lb down and 216 lb up at 28-0-0 on top chord, and 340 lb down and 129 lb up at 7-0-0, 81 lb down at 9-0-12, 81 lb down at 11-0-12, 81 lb down at 13-0-12, 81 lb down at 15-0-12, 81 lb down at 17-0-12, 81 lb down at 17-11-4, 81 lb down at 19-11-4, 81 lb down at 21-11-4, 81 lb down at 23-11-4, and 81 lb down at 25-11-4, and 340 lb down and 129 lb up at 27-11-4 on bottom chord. The design/selection of such connection device(s) is the responsibility of others. 11) "This manufactured product is designed as an individual building component. The suitability and use of this component for any particular building is the responsibility of the building designer per ANSI TPI 1 as referenced by the building code." LOAD CASE(S) Standard 1) Dead + Roof Live (balanced): Lumber Increase=1.25, Plate Increase=1.25 Uniform Loads (plf) Vert: 1-3=-54, 3-7=-54, 7-9=-54, 2-8=-20 Concentrated Loads (lb) Vert: 3=-105(B) 7=-133(B) 15=-340(B) 10=-340(B) 16=-105(B) 17=-105(B) 18=-105(B) 19=-105(B) 20=-105(B) 21=-105(B) 22=-105(B) 23=-105(B) 24=-105(B) 25=-105(B) 26=-58(B) 27=-58(B) 28=-58(B) 29=-58(B) 30=-58(B) 31=-58(B) 32=-58(B) 33=-58(B) 34=-58(B) 35=-58(B) Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component available from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 5/19/2020 BEFORE USE. 6904 Parke East Blvd. Tampa, FL 36610 Job WS0024 Truss V01 Truss Type Valley Qty 1 Ply 1 Job Reference (optional) T23501839 8.430 s Mar 22 2021 MiTek Industries, Inc. Thu Apr 8 08:15:06 2021 Page 1 Builders FirstSource (Tampa, FL), Tampa, FL - 33564, ID:JbsSUYEphcZuYTshvwE3BRyhOBX-ruTFSxGDdePY0sKrnmI4YwoKcmH40Vpwdnv8YqzSqyZ Scale = 1:12.2 1 2 3 4 2x4 2x4 2x4 4-6-3 4-6-3 0-0-41-10-95.00 12 LOADING (psf) TCLL TCDL BCLL BCDL 20.0 7.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.25 1.25 YES FBC2020/TPI2014 CSI. TC BC WB Matrix-P 0.48 0.26 0.00 DEFL. Vert(LL) Vert(CT) Horz(CT) in n/a n/a 0.00 (loc) - - 3 l/defl n/a n/a n/a L/d 999 999 n/a PLATES MT20 Weight: 15 lb FT = 20% GRIP 244/190 LUMBER- TOP CHORD 2x4 SP No.3 BOT CHORD 2x4 SP No.3 WEBS 2x4 SP No.3 BRACING- TOP CHORD Structural wood sheathing directly applied or 4-6-3 oc purlins, except end verticals. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS. (size)1=4-5-9, 3=4-5-9 Max Horz 1=74(LC 9) Max Uplift 1=-42(LC 12), 3=-46(LC 12) Max Grav 1=134(LC 1), 3=135(LC 17) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. NOTES-(7) 1) Wind: ASCE 7-16; Vult=165mph (3-second gust) Vasd=128mph; TCDL=4.2psf; BCDL=3.0psf; h=15ft; B=45ft; L=28ft; eave=4ft; Cat. II; Exp B; Encl., GCpi=0.18; MWFRS (directional) and C-C Exterior(2E) 0-9-1 to 3-9-1, Interior(1) 3-9-1 to 4-4-7 zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 2) Building Designer / Project engineer responsible for verifying applied roof live load shown covers rain loading requirements specific to the use of this truss component. 3) Gable requires continuous bottom chord bearing. 4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 5) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 42 lb uplift at joint 1 and 46 lb uplift at joint 3. 7) "This manufactured product is designed as an individual building component. The suitability and use of this component for any particular building is the responsibility of the building designer per ANSI TPI 1 as referenced by the building code."This item has been electronically signed and sealed by Velez, Joaquin, PE using a Digital Signature. Printed copies of this document are not considered signed and sealed and the signature must be verified on any electronic copies. April 9,2021 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component available from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 5/19/2020 BEFORE USE. 6904 Parke East Blvd. Tampa, FL 36610 Job WS0024 Truss V02 Truss Type Valley Qty 1 Ply 1 Job Reference (optional) T23501840 8.430 s Mar 22 2021 MiTek Industries, Inc. Thu Apr 8 08:15:06 2021 Page 1 Builders FirstSource (Tampa, FL), Tampa, FL - 33564, ID:JbsSUYEphcZuYTshvwE3BRyhOBX-ruTFSxGDdePY0sKrnmI4YwoQmmLS0Vpwdnv8YqzSqyZ Scale: 1.5"=1' 1 2 3 2x4 2x4 2x4 2-6-3 2-6-3 0-0-41-0-95.00 12 LOADING (psf) TCLL TCDL BCLL BCDL 20.0 7.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.25 1.25 YES FBC2020/TPI2014 CSI. TC BC WB Matrix-P 0.08 0.05 0.00 DEFL. Vert(LL) Vert(CT) Horz(CT) in n/a n/a 0.00 (loc) - - 3 l/defl n/a n/a n/a L/d 999 999 n/a PLATES MT20 Weight: 7 lb FT = 20% GRIP 244/190 LUMBER- TOP CHORD 2x4 SP No.3 BOT CHORD 2x4 SP No.3 WEBS 2x4 SP No.3 BRACING- TOP CHORD Structural wood sheathing directly applied or 2-6-3 oc purlins, except end verticals. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS. (size)1=2-5-9, 3=2-5-9 Max Horz 1=33(LC 9) Max Uplift 1=-19(LC 12), 3=-21(LC 12) Max Grav 1=60(LC 1), 3=60(LC 17) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. NOTES-(7) 1) Wind: ASCE 7-16; Vult=165mph (3-second gust) Vasd=128mph; TCDL=4.2psf; BCDL=3.0psf; h=15ft; B=45ft; L=28ft; eave=4ft; Cat. II; Exp B; Encl., GCpi=0.18; MWFRS (directional) and C-C Exterior(2E) zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 2) Building Designer / Project engineer responsible for verifying applied roof live load shown covers rain loading requirements specific to the use of this truss component. 3) Gable requires continuous bottom chord bearing. 4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 5) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 19 lb uplift at joint 1 and 21 lb uplift at joint 3. 7) "This manufactured product is designed as an individual building component. The suitability and use of this component for any particular building is the responsibility of the building designer per ANSI TPI 1 as referenced by the building code."This item has been electronically signed and sealed by Velez, Joaquin, PE using a Digital Signature. Printed copies of this document are not considered signed and sealed and the signature must be verified on any electronic copies. April 9,2021 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component available from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 5/19/2020 BEFORE USE. 6904 Parke East Blvd. Tampa, FL 36610 Job WS0024 Truss V03 Truss Type Valley Qty 1 Ply 1 Job Reference (optional) T23501841 8.430 s Mar 22 2021 MiTek Industries, Inc. Thu Apr 8 08:15:07 2021 Page 1 Builders FirstSource (Tampa, FL), Tampa, FL - 33564, ID:JbsSUYEphcZuYTshvwE3BRyhOBX-J40dgHHrOyXPd0v1KUpJ48LT0Ac2ly23sRei4GzSqyY Scale = 1:13.1 1 2 3 4 2x4 2x4 2x4 5-0-0 5-0-0 0-0-42-1-05.00 12 LOADING (psf) TCLL TCDL BCLL BCDL 20.0 7.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.25 1.25 YES FBC2020/TPI2014 CSI. TC BC WB Matrix-P 0.63 0.34 0.00 DEFL. Vert(LL) Vert(CT) Horz(CT) in n/a n/a 0.00 (loc) - - 3 l/defl n/a n/a n/a L/d 999 999 n/a PLATES MT20 Weight: 16 lb FT = 20% GRIP 244/190 LUMBER- TOP CHORD 2x4 SP No.3 BOT CHORD 2x4 SP No.3 WEBS 2x4 SP No.3 BRACING- TOP CHORD Structural wood sheathing directly applied or 5-0-0 oc purlins, except end verticals. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS. (size)1=4-11-6, 3=4-11-6 Max Horz 1=84(LC 9) Max Uplift 1=-47(LC 12), 3=-52(LC 12) Max Grav 1=152(LC 1), 3=153(LC 17) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. NOTES-(7) 1) Wind: ASCE 7-16; Vult=165mph (3-second gust) Vasd=128mph; TCDL=4.2psf; BCDL=3.0psf; h=15ft; B=45ft; L=28ft; eave=4ft; Cat. II; Exp B; Encl., GCpi=0.18; MWFRS (directional) and C-C Exterior(2E) 0-9-1 to 3-9-1, Interior(1) 3-9-1 to 4-10-4 zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 2) Building Designer / Project engineer responsible for verifying applied roof live load shown covers rain loading requirements specific to the use of this truss component. 3) Gable requires continuous bottom chord bearing. 4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 5) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 47 lb uplift at joint 1 and 52 lb uplift at joint 3. 7) "This manufactured product is designed as an individual building component. The suitability and use of this component for any particular building is the responsibility of the building designer per ANSI TPI 1 as referenced by the building code."This item has been electronically signed and sealed by Velez, Joaquin, PE using a Digital Signature. Printed copies of this document are not considered signed and sealed and the signature must be verified on any electronic copies. April 9,2021 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component available from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 5/19/2020 BEFORE USE. 6904 Parke East Blvd. Tampa, FL 36610 Job WS0024 Truss V04 Truss Type Valley Qty 1 Ply 1 Job Reference (optional) T23501842 8.430 s Mar 22 2021 MiTek Industries, Inc. Thu Apr 8 08:15:07 2021 Page 1 Builders FirstSource (Tampa, FL), Tampa, FL - 33564, ID:JbsSUYEphcZuYTshvwE3BRyhOBX-J40dgHHrOyXPd0v1KUpJ48LaWAg8ly23sRei4GzSqyY Scale = 1:9.0 1 2 3 2x4 2x4 2x4 3-0-0 3-0-0 0-0-41-3-05.00 12 LOADING (psf) TCLL TCDL BCLL BCDL 20.0 7.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.25 1.25 YES FBC2020/TPI2014 CSI. TC BC WB Matrix-P 0.15 0.08 0.00 DEFL. Vert(LL) Vert(CT) Horz(CT) in n/a n/a 0.00 (loc) - - 3 l/defl n/a n/a n/a L/d 999 999 n/a PLATES MT20 Weight: 9 lb FT = 20% GRIP 244/190 LUMBER- TOP CHORD 2x4 SP No.3 BOT CHORD 2x4 SP No.3 WEBS 2x4 SP No.3 BRACING- TOP CHORD Structural wood sheathing directly applied or 3-0-0 oc purlins, except end verticals. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS. (size)1=2-11-6, 3=2-11-6 Max Horz 1=43(LC 9) Max Uplift 1=-24(LC 12), 3=-27(LC 12) Max Grav 1=78(LC 1), 3=78(LC 17) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. NOTES-(7) 1) Wind: ASCE 7-16; Vult=165mph (3-second gust) Vasd=128mph; TCDL=4.2psf; BCDL=3.0psf; h=15ft; B=45ft; L=28ft; eave=4ft; Cat. II; Exp B; Encl., GCpi=0.18; MWFRS (directional) and C-C Exterior(2E) zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 2) Building Designer / Project engineer responsible for verifying applied roof live load shown covers rain loading requirements specific to the use of this truss component. 3) Gable requires continuous bottom chord bearing. 4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 5) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 24 lb uplift at joint 1 and 27 lb uplift at joint 3. 7) "This manufactured product is designed as an individual building component. The suitability and use of this component for any particular building is the responsibility of the building designer per ANSI TPI 1 as referenced by the building code."This item has been electronically signed and sealed by Velez, Joaquin, PE using a Digital Signature. Printed copies of this document are not considered signed and sealed and the signature must be verified on any electronic copies. April 9,2021 PRODUCT CODE APPROVALSLATERAL BRACING LOCATIONIndicates location where bearings(supports) occur. Icons vary butreaction section indicates jointnumber where bearings occur.Min size shown is for crushing only.Indicated by symbol shown and/orby text in the bracing section of theoutput. Use T or I bracingif indicated.The first dimension is the plate width measured perpendicular to slots. Second dimension isthe length parallel to slots.Center plate on joint unless x, yoffsets are indicated.Dimensions are in ft-in-sixteenths.Apply plates to both sides of trussand fully embed teeth.1. Additional stability bracing for truss system, e.g. diagonal or X-bracing, is always required. See BCSI.2. Truss bracing must be designed by an engineer. For wide truss spacing, individual lateral braces themselves may require bracing, or alternative Tor I bracing should be considered.3. Never exceed the design loading shown and never stack materials on inadequately braced trusses.4. Provide copies of this truss design to the building designer, erection supervisor, property owner and all other interested parties.5. Cut members to bear tightly against each other.6. Place plates on each face of truss at each joint and embed fully. Knots and wane at joint locations are regulated by ANSI/TPI 1.7. Design assumes trusses will be suitably protected from the environment in accord with ANSI/TPI 1.8. Unless otherwise noted, moisture content of lumber shall not exceed 19% at time of fabrication.9. Unless expressly noted, this design is not applicable for use with fire retardant, preservative treated, or green lumber.10. Camber is a non-structural consideration and is the responsibility of truss fabricator. General practice is to camber for dead load deflection.11. Plate type, size, orientation and location dimensions indicated are minimum plating requirements.12. Lumber used shall be of the species and size, and in all respects, equal to or better than that specified.13. Top chords must be sheathed or purlins provided at spacing indicated on design.14. Bottom chords require lateral bracing at 10 ft. spacing, or less, if no ceiling is installed, unless otherwise noted.15. Connections not shown are the responsibility of others.16. Do not cut or alter truss member or plate without prior approval of an engineer.17. Install and load vertically unless indicated otherwise.18. Use of green or treated lumber may pose unacceptable environmental, health or performance risks. Consult with project engineer before use.19. Review all portions of this design (front, back, words and pictures) before use. Reviewing pictures alone is not sufficient.20. Design assumes manufacture in accordance with ANSI/TPI 1 Quality Criteria.21.The design does not take into account any dynamic or other loads other than those expressly stated.Failure to Follow Could Cause PropertyDamage or Personal Injury (Drawings not to scale)© 2012 MiTek® All Rights ReservedMiTek Engineering Reference Sheet: MII-7473 rev. 5/19/2020edge of truss.from outside"16/1-0ICC-ES Reports:ESR-1311, ESR-1352, ESR1988ER-3907, ESR-2362, ESR-1397, ESR-3282JOINTS ARE GENERALLY NUMBERED/LETTERED CLOCKWISEAROUND THE TRUSS STARTING AT THE JOINT FARTHEST TOTHE LEFT.CHORDS AND WEBS ARE IDENTIFIED BY END JOINTNUMBERS/LETTERS.W 4 - 6 W3-6W3 - 7 W2-7W1-7C1-8 C5-6C6-7C7-8C4-5 C3-4C2-3C1-2TOP CHORD TOP CHORD 87654321BOTTOM CHORDSTOP CHORDSBEARING4 x 4PLATE SIZEThis symbol indicates the required direction of slots inconnector plates."16/1For 4 x 2 orientation, locateplates 0- 1"4/3PLATE LOCATION AND ORIENTATIONSymbolsNumbering SystemGeneral Safety Notes *Plate location details available in MiTek 20/20software or upon request.Industry Standards:ANSI/TPI1: National Design Specification for Metal Plate Connected Wood Truss Construction.DSB-89: Design Standard for Bracing.BCSI: Building Component Safety Information, Guide to Good Practice for Handling, Installing & Bracing of Metal Plate Connected Wood Trusses.6-4-8WEBSTrusses are designed for wind loads in the plane of the truss unless otherwise shown.Lumber design values are in accordance with ANSI/TPI 1 section 6.3 These truss designs rely on lumber values established by others.dimensions shown in ft-in-sixteenths