ST LUCIE COUNTY ROOFING PERMIT INFORMATION SHEET
Florida Building Code 7th Edition (2020)
Based on Section 1525 of the Florida Building Code -Building
INSTRUCTION PAGE
COMPLETE THE NECESSARY SECTIONS OF THE UNIFORM ROOFING SHEET
APPLICATION FORM AND ATTACH THE REQUIRED DOCUMENTS AS NOTED
BELOW:
Roof System
Required Sections of
the Permit Application
Form
Attachments Required
See List Below
Low Slope Application
A, B,C
1,2,3AAS.7.
Prescriptive BUR-RAS 150
A, B, C
2,4,5,6,7
Asphaltic Shingles
A, B, D
1,2,45,67
Concrete or Clay Tile
A, B, D,E
1,2,%4,5,6,7
Metal Roofs
A, B, D
1,2A4A6.7
Wood Shingles and
Shakes
A, B, D
1,2r1A6,7
Other
As Applicable
1A3,4,6,6,7
ATTACHMENTS REQUIRED As ADolicable):
1.
Fire Directory Listing Page
2.
From Product Approval:
Front Page
Specific System Description
Specific System Limitations
General Limitations
Applicable Detail Drawings
3.
Design Calculations per Chapter 16, or if applicable, RAS 127 or RAS 128
4.
Other Component of Product Approval
S.
Municipal Permit Application
6.
Owners Notification for Roofing Considerations (Reroofing Only)
7.
Any Required Roof Testing/Calculation Documentation
Form RaoflnfoFeb21 Rev Feb 18, 2021
ST. LUCIE
Section C (Low Slope Roof)
Fill in specific roof assembly components and identify
manufacturer
(If a component is not used, identify as "NA")
System Manufacturer:
Product Approval No.:
Design Wind Pressures, From RAS 128 Or Calculations:
Zone 1': _ Zone 1: _ Zone 2: _Zone 3: _
Max. Design Pressure, from the specific product approval
system:
Deck:
Type:
Gauge Thickness:
Slope:
Anchor/Base Sheet & No. df Ply(s):
Anchor/Base Sheet Fastener/Bonding Material:
Insulation Base Layer:
Base Insultation Size and Thickness:
Base Insulation Fastener/Bonding Material:
Top Insulation Layer:
Top Insulation Size and Thickness:
Top Insulation Fastener/Bonding Material:
Base Sheet(s) & No. of Ply(s):
Base Sheet Fastener/Bonding Material:
Ply Sheet(s)' & No. of Ply(s):
Ply Sheet Fastener/Bonding Material:
Top Ply:
Top Ply Fastener/Bonding Material:
Fastener Spacing for Anchor/Base Sheet Attachment:
Zone 1':
oc @ Lap, If Rows_ @ _" 03
Zone l_"oc@
Lap, # Rows _®_"m
Zone 2:—"
oc @ Lap, # Rows _ ® _" o s
Zone 3:_"
oc @ Lap, # Rows— @ _" ac
Number of Fasteners Per Insulation Board:
Zone 1':_Zone la Zone 2:—Zone 3:_
Illustrate Components Noted and Details as Applicable:
Woodblocking, Gutter, Edge Termination, Stripping,
Flashing, Continuous Cleat, Cant Strip, Base Flashing,
Counterflashing, Coping, Etc.,
Indicate: Mean Roof Height, Parapet Height, Height of Base
Flashing, Component Material, Material' Thickness, Fastener
Type, Fastener Spacing or Submit Manufacturers Details that
Comply with RAS 111 and Chapter 16..
5T.LUCE
Section D (Steep Slope Roof System)
Roof system Manufacturer: JA TAYLGR ROOFING 5V CRIMP
Notice of Acceptance Number: FL#17443.1
Minimum Design Wind Pressures, If Applicable (From RA5 127 or Calculations):
Zone 1: -57 Zone 2e: -57 Zone 2n:--9L2one 2r: -91 Zone 3e-91 Zone 3r:-128
Deck Type: PLYWOOD'
Type Underlayment EEL & STICK-OWENS CORNING TITANIUM-FL#11E02.1
Roof Slope:
5 : 12
Insulation:
Fire Barrier:
Ridge Ventilation? Fastener Type & Spacing: s° FIELD 14" PERIMETER, 8❑ RING SHANK NAILS
Adhesive Type:
\ypp Sheet: I F
Mean Roof -Height: 15' FT f Covering: METAL
Type & Size Drip 2„x„
Edge:
ST. LUCIE WORKS
Section E(Tile Calculations)
For Moment based tile systems, choose either Method 1 or 2. Compare the values for M, with the values from Mr. If the Mr values
are greater than or equal to the Mr values, for each area of the roof, then the the attachment method is acceptable.
Method 1'Moment Based Tile Calculations Per RAS 12T
(Zone 1: _xl,_= 1- Mg: _=M,i_ Product ApprovalM
(Zone 2e: _xt�= _ I- Mg: _-Mn_ Product Approval M.
(Zone 2n: '_x 7L =-Mg: _=Ma, _ Product ApprovalM
(Zone 2r: _xl_= )-Mg:_=M,p_ Product Approval Mr
(Zone 3e: '-x1_=, I-Mg:_=Mn,_ Product Approval M,
(Zone 3r: _Xi_= _)-Mg:_=Me- Product Approval M,
Method 2 "Simplified Tile Calculations Per Table Below"
Required Moment of Resistance (Mr) From Table Below- Product Aooroval Ms -
Mr required Moment Resistance"
Mean Roof Height Roof Slope
15'
20'
25'
30'
40'
2:12
34.4
36.5
38.2
39.7
42.2
3:12
32.2
34.4
36.0
37.4
39.8
4:12
30.4
32.2
33.8
35.1
37.3
5:12
28.4
30.1
31.6
32.8
34.9
6:12
26.4
28.0
29.4
30.5
32.4
7:12
24.4
25.9
27.1
28.2
30.0
'-must be used in conjunction with a hst of moment based tile systems
• For Uplift based tile systems use Method 3. Compare the values for F' with the values for F, If the F'values are greater than or
equal to the F, values, for each area of the roof, then the tile attachment method is acceptable.
Method 3 "Uplift Based Tile Calculations Per RAS 12T
(Zone 1: x L= x W:=_-W:_ cos r -Fri- Product Approval F'
(Zone 2e: _x L=xW:=)-W cos r=Foe_ Product Approval F'
(Zone 2n: xL=xW:=_)-W:_COS r F,a"_ Prod uct Approva l F'
(Zone 2r. _xL xW:= ---j-W: Cos r= F,2, Product Approval F'
(Zone 3e:_xL xW:- )-W:_Cosr =F,a. Product Ap prove[ F'
(Zone 3r. xL =x W:= )-W:_Cos r=F,3, Product Approval F
Whereto Obtain Information
Description
Symbol
Where to find
Design Pressure
Zones 1, 2e, 2n, 2r, 3e, 3r
From applicable table in RAS 127 or by an engineering analysis
prepared by PE based on ASCE 7
Mean Roof Height
H
Job Site
Roof Slope
B
Job Site
Aerodynamic Multiplier
a
Produtt Approval
Restoring Moment due to Gravity
Mr
Product Approval
Attachment Resistance
Mr
Product Approval
Required Moment Resistance
Mr
Calculated
Minimum Attachment Resistance
F
Product Approval
Required Uplift Resistance
F,
Calculated
Average Tile Weight
W
Product Approval
Tile Dimensions
L=length W=width
Product Approval
All calculations must be submitted to the building official at the time of Permit application.