HomeMy WebLinkAboutAPPROVED, 5-V Product ApprovalWOLTERS ENGINEERING ENGINEERING, DRAFTING, CONSULTING 15211 97th Road N West Palm Beach, FL 33412 Ph[Fx: (561) 225-1982 PRODUCT EVALUATION (FOR HVHZ APPROVED PRODUCT) PRODUCT: DM CLASS 500 26 GA. GALVALUME 5V CRIMP 24" WIDE ROOF PANEL (FLPA# 27499.20) MANUFACTURER: DYNAMIC METALS, LLC 3201 SE DOMINICA TERRACE STUART, FL 34997 To all concerned, The DM Class 500 Series 26 Ga. Galvalume 5V Crimp 24" Wide Roof Panel, manufactured by Dynamic Metals LLC, is a non-structural gaivalume coated Fluropon painted steel roof panel (50 ksi min) that meets the requirements of Sections 1507.4 and 1518.9 of the 7th Edition (2020) Florida Building Code. The panel has been tested per TAS 100 and TAS 125 by Intertek with results shown in test reports G3443.38-450-44 and H2686.02- 45044, and per TAS 110 by PRI Construction Materials Technologies, with results shown in test reports VLS-004- 02-01 and VLS-005.02-01. Technical Documentation: 1. Drawing "5VS-HZ" dated 8/15119, signed and sealed by Scott Wolters, PE. 2. Test Reports listed above by Architectural Testing, Inc. signed and sealed by Vinu Abraham, PE. 3. Test Reports listed above by PRI Construction Materials Technologies, signed and sealed by Zachary R Priest, PE. 4. Supplemental Calculations to support 5VS-HZ, signed and sealed by Scott Wolters, PE. I have reviewed this submittal per the requirements of FAC Product Approval Rule Chapter 61 G20-3.005 (4). Based on the limitations listed below and those provided in the documents above, this product meets all the requirements of the 7th Edition (2020) Florida Building Code generally, and chapter 15 specifically, including the HVHZ provisions. Limitations: This panel is approved for use inside and outside of the HVHZ. Overall Limitations: Maximum Panel Width: 24" (nominal) Fastener Spacing across panel 12" (at Overlaps & Center Rib) Min. Slope: HVHZ: 2"112" Non-HVHZ: W/12" (with Lap Sealant) 3712" (no Lap Sealant) 9'rcCIAI.IZIN6 IN IMPACf Of515fANT CI.RfAJNWAl.i.5, 5f0�T-i=FONf5, & WINPOW5 Option #1 Installation Option #2 Installation Max. Design Pressure: -117.75 psf -206 psf Fastener Spacing: 4" From Ends,16" Max. O.C. 4" From Ends, 8" Max. O.C. Min Panel Fasteners: #10x1 1/2" HiLo HWH Screw with Weather -seal Washer #10x1 1/2" HiLo HWH Screw with Weather -seal Washer Fire Barrier: Where required by code, install an approved fire barrier. Refer to a current fire directory listing for fire ratings of this roofing system assembly as well as the location of the fire barrier within the assembly. (See note #2 below) Note: Outside of the HVHZ, in areas with windspeeds < 170 mph, 1" round plastic caps meeting the requirements of FBC Section 1507.1.1.1, may be used to prevent galvanic reactions. Underlavment: Minimum ASTM D 226 Type Il, installed and anchored per FBC Section 1507.1.1.1 (min). (or) Any underlayment with a valid FLPA or Miami -Dade NOA Note: Outside of the HVHZ, in areas with windspeeds < 170 mph, 1" round plastic caps meeting the requirements of FBC Section 1507.1.1.1 may be used to prevent galvanic reactions. Minimum Substrate: Y2' (15/32" min) 4-ply CDX Plywood or W' solid wood planks (S.G. = .42 min) nailed to 2x rafters spaced 24" max. on center with 8d ring -shank nails spaced 5' on center. Note: The 3/4" wood planking must be installed as a solid deck and must be nailed or fastened in a manner equal to the deck above, or as specified by a Florida licensed Architect/Engineer Other Limitations: 1. Roof slope must meet requirements of FBC Sections 1507.4.2 or 1515.2. 2. Fire classification is not a part of this evaluation. Refer to a current Approved Roofing Materials Directory for fire ratings of this product. 3. Design of substrate is by others and is not a part of this evaluation. 5PECIA,IZING IN IMPACT F: 515TANT & WINPOW5 4. All panel system perimeters, penetrations, and transitions to be flashed and sealed per the requirements of RAS 133. 5. Rational analysis, provided by a Florida licensed Architect/Engineer per FAS 61 G20.3.005(e), may be used for project specific approval by the local authorities having jurisdiction. 6. Where required by the Florida Building Code, panels shall be permanently labeled with the manufacturer's name and/or logo, and the following statement, "Dynamic Metals FL #27499.20, DM Class 500". Panel Forming: These panels may be jobsite roll formed with the following Dynamic Metals machines, per approval of 31d party QA provider, to the dimensions shown on Drawing 5VS-HZ: SSQ-6800617 SSQ-5150216 SSQ-6810617 SSQ-6690517 SSQ-4560615 SSQ2-2310920 5VC-0490718 5VC-0360516 SSQ2-2320920 Re -Roofing: The DM Class 500 Series 26 Ga. Galvalume 5V Crimp 24" Wide Roof Panel may be installed over a single layer of existing asphalt shingles, provide the existing roof meets the requirements of Section 1511 of the Florida Building Code. If you have any questions or need more information concerning this approval, please contact me. Thank you, �GO 14 \VQ� No 62354 Scott Wolters * = FL PE# 62354 3 • STATE OF '4 APR 15 2021 oT• P '�u �OR1�. 5P�CIAI.IZIN6 IN IMPACT M95fANf Cu'fAINWAl.l.5. 5f0IPRONf5, & WINPOW5 � v ic i ar. G7 D cn c /- al i Q r c C cr R m c� m � � O -0 T N \ ryny J H [A `a