ST LUCIE COUNTY ROOFING PERMIT INFORMATION SHEET
Florida Building Code 7th Edition (2020)
Based on Section 1525 of the Florida Building Code - Building
INSTRUCTION PAGE
COMPLETE THE NECESSARY SECTIONS OF THE UNIFORM ROOFING SHEET
APPLICATION FORM AND ATTACH THE REQUIRED DOCUMENTS AS NOTED
BELOW:
Roof System
Required Sections of
the Permit Application
Form
Attachments Required
See List Below
Low Slope Application
A, B, C
1XA4,5A7
Prescriptive BUR-RAS 150
A, B, C
2,4,5,6,7
Asphaltic Shingles
A, B, D
IA4,5A7
Concrete or Clay Tile
A, B, D, E
1,2,9r4AG.T.
Metal Roofs
A, 8, D
1,2A4.5,8;7'
Wood Shingles and
Shakes
A, B, D
1,2,4,8,8.7
Other
As Applicable
IA%4.5,8,7
ATTACHMENTS REQUIRED As Applicable):
1.
Fire Directory Listing Page
From Product Approval:
2.
Front Page
Specific System Description
Specific System Limitations
General Limitations
Applicable Detail Drawings
Design Calculations per Chapter 16, or If applicable, RAS 127 or RAS 128
3.
4.
Other Component of Product Approval
S.
Municipal Permit Application
6.
Owners Notification for Roofing Considerations (Reroofing Only)
7,
Any Required Roof Testing/Calculation Documentation
Form RooflnfoFeb21 Rev Feb 18, 2021
ST. LUCIE WORKS
Section D (Steep Slope Roof System)
Roof System Manufacturer: i
Notice of Acceptance Number:
Minimum Design Wind Pre cures, If Applicable (From RAS 127 or Calculations):
Zone 1:14 2e:4 Zone 2n:7one 2r:iffiZone 3e� I�_Zone 3r: — I ZP'
Deck Type:
Type Underiayment
Roof Slope:
-: 121 Insulation:
Fire Barrier: N
Ridge V flation? Fastener Type & Spacing: F# C) x
Adhesive Type: JA
Type Cap Sheet
Mean Rool'Height: G Roof Covering; . V6 a
Type & Siza Drip(
Edge:
Section A (General Information)
Master Permit No. Process No.
Contractors Name:' ` VI cense# . �.�]li 4Pej
Job Address 3 4 i 1� , U ,. n_ �}
ROOF CATEGORY
❑ Low Slope ❑ Mechanically Fastened Tile ❑ Mortar/Adhesive Set Tiles
❑ Asphaltic Shingles Q'Metal Panel/Shingles ❑Wood Shingles/Shakes
❑ Prescriptive BUR-RAS 150
ROOF ROOF TYPE.
❑ New roof ❑ Repair ❑ Maintenance 'b Reroofing ❑ Recovering
. ROOF SYSTEM INFORMATION
Low Slope Roof Area (5F) , I Steep Sloped Roof Area (SF)
Total (5F)
Section B (Roof Plan)
Sketch Roof Plan: Illustrate all levels and sections, roof drains, scuppers, overflow scuppers and overflow drains.
Include dimensions of sections and levels, clearly identify dimensions of elevated pressure zones and location of parapets.
14' 10"
7T— -7
1'11"
2B'0"