Loading...
HomeMy WebLinkAboutAPPROVED,, NOA 20-0519.09 FIXED WINDOW NOA No. 20-0519.09 Expiration Date: September 22, 2025 Approval Date: October 10, 2020 8/31/20 Page 1 MIAMI-DADE COUNTY PRODUCT CONTROL SECTION 11805 SW 26 Street, Room 208 DEPARTMENT OF REGULATORY AND ECONOMIC RESOURCES (RER) Miami, Florida 33175-2474 BOARD AND CODE ADMINISTRATION DIVISION T (786) 315-2590 F (786) 315-2599 NOTICE OF ACCEPTANCE (NOA) www.miamidade.gov/building CGI Windows and Doors, Inc. 3780 W 104th Street Hialeah, FL 33018 SCOPE: This NOA is being issued under the applicable rules and regulations governing the use of construction materials. The documentation submitted has been reviewed and accepted by Miami-Dade County RER - Product Control Section to be used in Miami Dade County and other areas where allowed by the Authority Having Jurisdiction (AHJ). This NOA shall not be valid after the expiration date stated below. The Miami-Dade County Product Control Section (In Miami Dade County) and/or the AHJ (in areas other than Miami Dade County) reserve the right to have this product or material tested for quality assurance purposes. If this product or material fails to perform in the accepted manner, the manufacturer will incur the expense of such testing and the AHJ may immediately revoke, modify, or suspend the use of such product or material within their jurisdiction. RER reserves the right to revoke this acceptance if it is determined by Miami-Dade County Product Control Section that this product or material fails to meet the requirements of the applicable building code. This product is approved as described herein and has been designed to comply with the Florida Building Code, including the High Velocity Hurricane Zone. DESCRIPTION: Series “Sentinel 130" Aluminum Fixed Window – L.M.I. APPROVAL DOCUMENT: Drawing No. PW130LMI-NOA, titled “‘Sentinel’ Series 130 Fixed Window - LM”, sheets 1 through 7 of 7, dated 05/22/19, with revision A dated 05/07/20, prepared by manufacturer, signed and sealed by Anthony Lynn Miller, P.E., bearing the Miami-Dade County Product Control Revision stamp with the Notice of Acceptance number and expiration date by the Miami-Dade County Product Control Section. MISSILE IMPACT RATING: Large and Small Missile Impact Resistant LABELING: Each unit shall bear a permanent label with the manufacturer's name or logo, city, state, model/series, and following statement: "Miami-Dade County Product Control Approved", unless otherwise noted herein. RENEWAL of this NOA shall be considered after a renewal application has been filed and there has been no change in the applicable building code negatively affecting the performance of this product. TERMINATION of this NOA will occur after the expiration date or if there has been a revision or change in the materials, use, and/or manufacture of the product or process. Misuse of this NOA as an endorsement of any product, for sales, advertising or any other purposes shall automatically terminate this NOA. Failure to comply with any section of this NOA shall be cause for termination and removal of NOA. ADVERTISEMENT: The NOA number preceded by the words Miami-Dade County, Florida, and followed by the expiration date may be displayed in advertising literature. If any portion of the NOA is displayed, then it shall be done in its entirety. INSPECTION: A copy of this entire NOA shall be provided to the user by the manufacturer or its distributors and shall be available for inspection at the job site at the request of the Building Official. This NOA revises and renews NOA# 19-0603.02 and consists of this page 1 and evidence pages E-1, E-2, E-3, E-4 and E-5, as well as approval document mentioned above. The submitted documentation was reviewed by Manuel Perez, P.E. Manuel Perez, P.E. Product Control Examiner NOA No. 20-0519.09 Expiration Date: September 22, 2025 Approval Date: October 10, 2020 E - 1 CGI Windows and Doors, Inc. NOTICE OF ACCEPTANCE: EVIDENCE SUBMITTED 1. EVIDENCE SUBMITTED UNDER PREVIOUS NOA’s A. DRAWINGS 1. Manufacturer's die drawings and sections. (Submitted under NOA No. 10-0510.13) 2. Drawing No. PW130LMI-NOA, titled “Sentinel 130 Alum Fixed Window (L.M.I.)(S.M.I.)”, sheets 1 through 7 of 7, dated 05/22/19, prepared by manufacturer, signed and sealed by Anthony Lynn Miller, P.E. (Submitted under NOA No.19-0603.02) B. TESTS 1. Test reports on: 1) Uniform Static Air Pressure Test, Loading per FBC, TAS 202-94 2) Large Missile Impact Test per FBC, TAS 201-94 3) Cyclic Wind Pressure Loading per FBC, TAS 203-94 along with marked-up drawings and installation diagram of a series 560 aluminum sliding glass door, prepared by Fenestration Testing Laboratory, Inc., Test Report No. FTL-19-8916, dated 04/10/19, signed and sealed by Idalmis Ortega, P.E. (Submitted under NOA No.19-0603.02) 2. Test reports on: 1) Uniform Static Air Pressure Test, Loading per FBC, TAS 202-94 2) Water Resistance Test, per FBC, TAS 202-94 3) Small Missile Impact Test per FBC, TAS 201-94 4) Large Missile Impact Test per FBC, TAS 201-94 5) Cyclic Wind Pressure Loading per FBC, TAS 203-94 along with marked-up drawings and installation diagram of a series 130 and 410 aluminum fixed windows, prepared by Fenestration Testing Laboratory, Inc., Test Report No. FTL-19-8917, dated 04/09/19, signed and sealed by Idalmis Ortega, P.E. (Submitted under NOA No.19-0603.02) 3. Test reports on: 1) Uniform Static Air Pressure Test, Loading per FBC TAS 202-94 2) Large Missile Impact Test per FBC, TAS 201-94 3) Cyclic Wind Pressure Loading per FBC, TAS 203-94 along with marked-up drawings and installation diagram of a series 7500 PVC fixed window, to qualify DuPont “Butacite” PVB interlayer, Duraseal® and Super Spacer® insulating glass spacer, prepared by Certified Test Laboratories, Test Report No. CTLA–3056 WA, dated 03/03/15, signed and sealed by Ramesh C. Patel, P.E. (Submitted under NOA No.15-0413.03) Manuel Perez, P.E. Product Control Examiner NOA No. 20-0519.09 Expiration Date: September 22, 2025 Approval Date: October 10, 2020 E - 2 CGI Windows and Doors, Inc. NOTICE OF ACCEPTANCE: EVIDENCE SUBMITTED 1. EVIDENCE SUBMITTED UNDER PREVIOUS NOA’s (CONTINUED) B. TESTS (CONTINUED) 4. Test reports on: 1) Uniform Static Air Pressure Test, Loading per FBC TAS 202-94 2) Large Missile Impact Test per FBC, TAS 201-94 3) Cyclic Wind Pressure Loading per FBC, TAS 203-94 along with marked-up drawings and installation diagram of a series 7400 PVC project out window, to qualify DuPont “Butacite” PVB interlayer, Duraseal® and Super Spacer® insulating glass spacer, prepared by Certified Test Laboratories, Test Report No. CTLA–3056 WB, dated 03/03/15, signed and sealed by Ramesh C. Patel, P.E. (Submitted under NOA No.15-0413.03) 5. Test reports on: 1) Uniform Static Air Pressure Test, Loading per FBC TAS 202-94 2) Large Missile Impact Test per FBC, TAS 201-94 3) Cyclic Wind Pressure Loading per FBC, TAS 203-94 along with marked-up drawings and installation diagram of a series 238 aluminum fixed window, to qualify DuPont “Butacite” PVB interlayer, Duraseal® and Super Spacer® insulating glass spacer, prepared by Certified Test Laboratories, Test Report No. CTLA–3056 WC, dated 04/16/15, signed and sealed by Ramesh C. Patel, P.E. (Submitted under NOA No. 15-0413.03) 6. Test reports on: 1) Air Infiltration Test, per FBC, TAS 202-94 2) Uniform Static Air Pressure Test, Loading per FBC TAS 202-94 3) Water Resistance Test, per FBC, TAS 202-94 4) Small Missile Impact Test per FBC, TAS 201-94 5) Cyclic Wind Pressure Loading per FBC, TAS 203-94 along with marked-up drawings and installation diagram of a Sentinel 130 aluminum fixed window, prepared by Hurricane Test Laboratory, Test Report No. HTL 0080-0130-10, dated 03/30/10, signed and sealed by Vinu J. Abraham, P.E. (Submitted under NOA No.10-0510.13) C. CALCULATIONS 1. Anchor verification calculations and structural analysis, complying with FBC 6th Edition (2017), dated July 15, 2017, prepared by Al-Farooq Corporation, signed and sealed by Javad Ahmad, P.E. (Submitted under NOA No.17-0918.07) 2. Glazing complies with ASTM E1300-09. D. QUALITY ASSURANCE 1. Miami-Dade Department of Regulatory and Economic Resources (RER) Manuel Perez, P.E. Product Control Examiner NOA No. 20-0519.09 Expiration Date: September 22, 2025 Approval Date: October 10, 2020 E - 3 CGI Windows and Doors, Inc. NOTICE OF ACCEPTANCE: EVIDENCE SUBMITTED 1. EVIDENCE SUBMITTED UNDER PREVIOUS NOA’s (CONTINUED) E. MATERIAL CERTIFICATIONS 1. Notice of Acceptance No. 17-0808.02 issued to Kuraray America, Inc. for their “SentryGlas® (Clear and White) Glass Interlayers” dated 12/28/17, expiring on 07/04/23. 2. Notice of Acceptance No. 17-1114.14 issued to Kuraray America, Inc. for their “Trosifol® Ultraclear, Clear and Color PVB Glass Interlayers” dated 01/18/18, expiring on 07/08/19. 3. Notice of Acceptance No. 18-0301.06 issued to Eastman Chemical Company (MA) for their “Saflex CP - Saflex and Saflex HP Composite Glass Interlayers with PET Core” dated 05/17/18, expiring on 12/11/23. 4. Notice of Acceptance No. 17-0712.05 issued to Eastman Chemical Company (MA) for their “Saflex Clear and Color Glass Interlayers” dated 09/07/17, expiring on 05/21/21. F. STATEMENTS 1. Statement letter of conformance, complying with FBC 6th Edition (2017), dated May 23, 2019, issued by manufacturer, signed and sealed by A. Lynn Miller, P.E. (Submitted under NOA No.19-0603.02) 2. Statement letter of no financial interest, dated May 23, 2019, issued by manufacturer, signed and sealed by A. Lynn Miller, P.E. (Submitted under NOA No.19-0603.02) 3. Proposal No. 19-0219 issued by the Product Control Section, dated March 13, 2019, signed by Ishaq Chanda, P.E. (Submitted under NOA No.19-0603.02) 4. Notification of Successor Engineer for manufacturer’s NOA document per Section 61G15-27.001 of the Florida Administrative Code, notifying original engineer that the successor engineer is assuming full professional and legal responsibility for all engineering documents pertaining to this NOA, dated May 22, 2019, signed and sealed by A. Lynn Miller, P.E. (Submitted under NOA No.19-0603.02) 5. Laboratory compliance letter for Test Report No. HTL-0080-0103-10, issued by Hurricane Test Laboratory, LLC, dated March 30, 2010, signed and sealed by Vinu J. Abraham, P.E. (Submitted under NOA No.10-0510.13) 6. Test Proposal for the qualification of Butacite® PVB glass interlayer by Kuraray America, Inc., as well as Duraseal® and Super Spacer® Standard warm-edge flexible insulating glass spacers, dated December 16, 2014, issued by RER, Product Control Section, signed by Jaime Gascon, P.E., Supervisor, Product Control Section. (Submitted under NOA No. 15-0413.03) Manuel Perez, P.E. Product Control Examiner NOA No. 20-0519.09 Expiration Date: September 22, 2025 Approval Date: October 10, 2020 E - 4 CGI Windows and Doors, Inc. NOTICE OF ACCEPTANCE: EVIDENCE SUBMITTED 1. EVIDENCE SUBMITTED UNDER PREVIOUS NOA’s (CONTINUED) G. OTHERS 1. Notice of Acceptance No. 17-0918.07, issued to CGI Windows and Doors, Inc. for their Series “Sentinel 130” Aluminum Fixed Window - L.M.I. approved on 11/22/17 and expiring on 09/22/20. 2. NEW EVIDENCE SUBMITTED A. DRAWINGS 1. Drawing No. PW130LMI-NOA, titled “‘Sentinel’ Series 130 Fixed Window - LM”, sheets 1 through 7 of 7, dated 05/22/19, with revision A dated 05/07/20, prepared by manufacturer, signed and sealed by Anthony Lynn Miller, P.E. B. TESTS 1. Test reports on: 1) Air Infiltration Test, per FBC, TAS 202-94 2) Uniform Static Air Pressure Test, Loading per FBC, TAS 202-94 3) Water Resistance Test, per FBC, TAS 202-94 4) Large Missile Impact Test per FBC, TAS 201-94 5) Cyclic Wind Pressure Loading per FBC, TAS 203-94 6) Forced Entry Test, per ASTM F588 and TAS 202-94 along with marked-up drawings and installation diagram of all PGT Industries, Inc. CGI Windows and Doors, Inc., representative units listed below and tested to qualify Dowsil 791 and Dowsil 983 silicones, per Proposal #19-1155TP, prepared by Fenestration Testing Laboratory, Inc., Test Reports No.: PGT Industries, Inc. test specimens: FTL-7897, PGT PW5520 PVC Fixed Window (unit 6 in proposal), dated 09/03/14 FTL-20-2107.1, PGT SGD780 Aluminum Sliding Glass Door (unit 7 in proposal) FTL-20-2107.2, PGT CA740 Alum. Outswing Casement Window (unit 8 in proposal) FTL-20-2107.3, PGT PW7620A Aluminum Fixed Window (unit 9 in proposal) and FTL-20-2107.4, PGT PW7620A Aluminum Fixed Window (unit 10 in proposal) all dated 07/13/20 and signed and sealed by Idalmis Ortega, P.E. CGI Windows and Doors Inc. test specimens: FTL-20-2108.1, CGI SH360 Aluminum Single Hung Window (unit 1 in proposal) FTL-20-2108.2, CGI CA238 Alum. Outswing Casement Window (unit 2 in proposal) FTL-20-2108.3, CGI SGD560 Aluminum Sliding Glass Door (unit 3 in proposal) FTL-20-2108.4, CGI PW410 Aluminum Fixed Window (unit 4 in proposal) and FTL-20-2108.5, CGI SH360 Aluminum Single Hung Window (unit 5 in proposal) all dated 08/24/20 and signed and sealed by Idalmis Ortega, P.E Manuel Perez, P.E. Product Control Examiner NOA No. 20-0519.09 Expiration Date: September 22, 2025 Approval Date: October 10, 2020 E - 5 CGI Windows and Doors, Inc. NOTICE OF ACCEPTANCE: EVIDENCE SUBMITTED 2. NEW EVIDENCE SUBMITTED (CONTINUED) C. CALCULATIONS 1. Anchor verification calculations and structural analysis, complying with FBC 6th Edition (2017), dated 07/15/17, prepared by Al-Farooq Corporation, signed and sealed by Javad Ahmad, P.E., updated to comply with FBC 7th Edition (2020), on 05/11/20 by manufacturer, signed and sealed by Anthony Lynn Miller, P.E. D. QUALITY ASSURANCE 1. Miami-Dade Department of Regulatory and Economic Resources (RER) E. MATERIAL CERTIFICATIONS 1. Notice of Acceptance No. 18-0725.11 issued to Kuraray America, Inc. for their “Kuraray SentryGlas® XtraTM (SGXTM) Clear Glass Interlayer” dated 05/23/19, expiring on 05/23/24. 2. Notice of Acceptance No. 19-0305.02 issued to Kuraray America, Inc. for their “Trosifol® Ultraclear, Clear and Color PVB Glass Interlayers” dated 05/09/19, expiring on 07/08/24. 3. Notice of Acceptance No. 18-0301.06 issued to Eastman Chemical Company (MA) for their “Saflex CP - Saflex and Saflex HP Composite Glass Interlayers with PET Core” dated 05/17/18, expiring on 12/11/23. 4. Notice of Acceptance No. 17-0712.05 issued to Eastman Chemical Company (MA) for their “Saflex Clear and Color Glass Interlayers” dated 09/07/17, expiring on 05/21/21. F. STATEMENTS 1. Statement letter of conformance, of complying with FBC 6th Edition (2017), and FBC 7th Edition (2020), dated May 07, 2020, issued by manufacturer, signed and sealed by Anthony Lynn Miller, P.E. 2. Statement letter of no financial interest, dated May 07, 2020, issued by manufacturer, signed and sealed by Anthony Lynn Miller, P.E. 3. Proposal No. 19-1155 TP issued by the Product Control Section, dated January 10, 2020, signed by Ishaq Chanda, P.E. G. OTHERS 1. Notice of Acceptance No. 19-0603.02, issued to CGI Windows and Doors, Inc. for their Series “Sentinel 130” Aluminum Fixed Window - L.M.I. approved on 07/03/19 and expiring on 09/22/20.