HomeMy WebLinkAboutProject Information Q ' e
File ,LUCIE WORKS
ST LUCIE COUNTY ROOFING PERMIT INFORMATION SHEET RECEIVED
JUN 0 0 2021
Florida Building Code 7th Edition (2020) st:relbFRiIP®� *
Based on Section 1525 of the Florida Building Code-Building
INSTRUCTION PAGE
COMPLETE THE NECESSARY SECTIONS OF THE UNIFORM ROOFING SHEET
APPLICATION FORM AND ATTACH THE REQUIRED DOCUMENTS AS NOTED
BELOW:
Required Sections of Attachments Required
.Roof System the Permit Application See List Below
Form'
Low Slope Application A, B,C 124; 67
Prescriptive BUR-RAS 150 A,B,C 2,4,5,6,7
Asphaltic Shingles A, B, D 1;24;567
Concrete or Clay Tile A,B, D, E 14,567
Metal Roofs A,B, D
Wood Shingles and A, B, D ts2;4 .67
Shakes
Other As Applicable 12' 4, �7
ATTACHMENTS REQUIRED As Applicable):
1. Fire Directory Listing Page
2. From Product Approval:
Front Page
Specific System Description
Specific System Limitations
General Limitations
Applicable Detail Drawings
3. Design Calculations per Chapter 16,or if applicable, RAS 127 or RAS 128
4. Other Component of Product Approval
5. Municipal Permit Application
6. Owners Notification for Roofing Considerations(Reroofing Only)
7. Any Required Roof Testing/Calculation Documentation
Form RooflnfoFeb21 Rev Feb 18,2021
ST. LUCIE WORKS VIEfOE® FOR
File w.,�•
CODE COMPLIANCE
Section A(General Information) ST. L CIE COUNTY
®CC CP0 u
Master Permit No. Process No.
Contractors Name:�h5`tn1ulrn�-�INC� u License# f.CLc:SSS-z3 1D2�'—t
Job Address 7_S(3 Cam` 1:2— 6cEF)05e_' fc— 3tt7kI
ROOF CATEGORY
; Low Slope 0 Mechanically Fastened Tile [3 Mortar/Adhesive Set Tiles
f,fAsphaltic Shingles 0 Metal Panel/Shingles OWood Shingles/Shakes
0 Prescriptive BUR-RAS 150
ROOF ROOF TYPE-
0 New roof 0 Repair 0 Maintenance K Reroofing 0 Recovering
.ROOF SYSTEM INFORMATION
Low Slope Roof Area (SF) (O Steep Sloped Roof Area(SF) ?3(L=6--' Total (SF) ?eO
Section B(Roof Plan)
Sketch Roof Plan: Illustrate all levels and sections, roof drains, scuppers, overflow scuppers and overflow drains.
Include dimensions of sections and levels,clearly identify dimensions of elevated pressure zones and location of parapets.
Page 1 of 1
za
Im
2s,
� x
i
file:///C:/IJsers/HUMPHR 1/AppData/Local/Temp/Low/PYJIGG2V.htm .6/9/2021
keED FOR
ST. LUCIE WORKS-. Cr®®E C®MPLIANGE
ST. LUCIE CpjgP � Z(
Section C(Low Slope Roof) Surfa IVAIfo
Fill in specific roof assembly components and identify Fastener Spacing for Anchor/Base Sheet Attachment:
manufacturer Zone 1':—"oc @ Lap,#Rows—
(If a component is not used,identify as"NA")
Zone 1:r." oc @Lap,#Rows 0: -'°
System Manufacturer: Qa�_Y &LA'S5 Zone 2:r." oc @ Lap,#Rows
Product Approval No.: � Zone 3:—."oc @ Lap,#Rows '
L ����' ��
Number of Fasteners Per Insulation Board:
Design Wind Pressures,From RAS 128 Or Calculations: Zone 1': Zone 1: Zone 2: Zone 3:
Zone 1,; Zone 1:3`l,l Zone 2r133Zone 3:ZR_A Illustrate Components Noted and Details as Applicable:
Max. Design Pressure,from the specific product approval Woodblocking, Gutter, Edge Termination, Stripping,
system: _ q0.0 Flashing, Continuous Cleat, Cant Strip, Base Flashing,
Counterflashing,Coping, Etc..
Deck: Indicate: Mean Roof Height, Parapet Height, Height of Base
Type: PLKwyt�`rJ Flashing,Component Material,Material'Thickness,Fastener
f f Type,Fastener Spacing or Submit Manufacturers Details that
Gauge Thickness: �7 t��� S l3 Z Comply with RAS 111 and Chapter 16..
Slope: I (Z•
Anchor/Base Sheet&No.df Ply(s):
Anchor/Base Sheet Fastener/Bonding Material: FT.
Insulation Base Layer: Al A
Base Insultation Size and Thickness: Parapet
Base Insulation Fastener/Bonding Material: Height
Top Insulation Layer:
Top Insulation Size and Thickness: FT.
Top Insulation Fastener/Bonding Material:
_ Mean
Base Sheet(s)&No.of Ply(s): Roof
Base Sheet Fastener/Bonding Material: Height
Ply Sheet(s)'&No.of Ply(s):
Ply Sheet Fastener/Bonding Material:
Top Ply: )0D17L((eb f2rccuuu /kPQ—'l A �Ocy�ie� Gl'
Top Ply Fastener/Bonding Material:
l'o P:�ec 1�PLLEn .
f`
'h ST.. LUCIE WORKS
Section D (Steep Slope Roof System) rC267`'E P G�
DW�N7 G012Ntll�C� •— • 5'(-�'U��(�i�
Roof System Manufacturer:
Notice of Acceptance Number: 'F(- 3A539
Minimum Design Wind Pressures, If Applicable(From RAS 127 or Calculations):
Zone 1%3LI OZone 2e=t aZone 2n: Zone 2r: Zone 3enLf'OZone 3r:
Q.ecicTjtpe' lI tj uc
Type<UnderlboM it �
;Roof Slope
_� _ 12 Irisulatio� `
l=tt�t BaCr_ier �•
Ridge Ventaaiaon FWgnar Types$Sppow
Ad s, Type:
T.ypeCap:Sheet<
Meen Roof Height: .h c Roof.Corr h j8.
Type B�Oze Drip: :2C,
a'l2 /N Ltv d c�CE