HomeMy WebLinkAboutProduct Approval (2) r � Mika
a —Mb= II r�n,� u isat am Il l4 �,+ au s � El m II am,►s ci$I� acc �w Il W04i 0
I ATM.
. E�iitL�.trr,Y®rm�SlPo�ra�actmau�tz�x�tua+scau�ar-Mar�w�maQouss�t�n�ar�Eran�in File COPY
NEW
JUN 0 9 2021
St.Lucie County uG� (Jyll/
Perm
IE E CI
QNmnmts
CODE COMPLIANCE
T.LUCIE COUNTY
�¢ 71 n ozem IC=dng ftr!W.V ww'OrTmOr
mdGH
lAt�131himrir� � ¢z�Ater
1fe¢IhraiS�il �
eaditw+±monmanrRrs e7�
Ad maseR u+e'd5=11
Rw8'rrg
Sm&mUmm=w ulndeffiYnre"s
Q=Ofem,m ff G afue&ian Raw,t 6Gmm a Rini ift Rags berredAir¢Hri1z or a Uman 5 ad UT=idO
nz�n
B+arxtauan+Repwt- moved
our Ram Mwm wffm&-jel'mped the Za&zry P_Phest
E alr n
FbuwbD rmmse FEE 7
a m Consburrmao 6RateffabTechann{Imai836 UZ
Conixact EW&affw Date 1MUM4
Wmtated HVI Steven M.&boo,m
Va rdatfmen ChedEst-Hardeaff moved
Certi&ncate aff IndeWdence U M539 RO Q.17H GCRMW 2M FBC Evail M-Ma Gonglar pdt;
5tw derd end Year(of Standard) Standard Meer
ASYM D 1970 2015
ASTM D 226 2W9
Equfva;lenoe of Product Starndaeds
CeetrEred BY
Sections from the.Code
Product Approval Method Method 1 Option D
I Ce,10 ate of Aun,os¢af/on No.29824
(� W I 17520 Edin�Yrurgh Drive
�1 I Tampa,FL 33647
T AL SERV CES, LLC (813)480-3421
EVALUAMON 1UPO 8 A' FLOMA BU 00113 COW,7T"EDrrN(2020)
Manufaztia7er. BEACON SALES ACQUISITIONS,INC. Issued October 14,2020
c/o OWENS CORNING ROOFING AND ASPKALT
LLC
1 Owens Coming Parkway
Toledo,Off 43657
(800)438-7465
www.owenscoserx ng.com
Hanuffactudng lLocadow Houston,TX
Brentwood,NH
QualBy Assurance: PRI Construction Materials Technologies,LLC(QUA9110)
SCOPE
Category: Roofing
Subcategory: Underlayments
Code Sections: 1507.1.1,1507.1.1.1
Properties: Physical properties
REFERENCES
Entity Report No. Standard Year
PRI Construction Materials Technologies(TST6049) OCF-294-02-01 ICC-ES AC 188' 2012
ACC-ES AC 48 2012
PRI Construction Materials Technologies(TST6049) OCF-338-02-01 ASTM iD 1970 2015a
'Determined to be equivalent to ASTM D 22"9,Type 11
PRODUCT DESCRIPTION
TRI-BUILT Granular A self-adhered underlayment used as an alternative to ASTM D 226,Type II roofing felt.
Underlayment The underlayment is composed of SBS modified asphalt with a fiberglass mat internal
reinforcement and is surfaced with granules. The product is supplied with a nominal
thickness of 50 mils in 1.95-sq rolls with nominal dimensions of 3-ft x 65-ft. See
manufacturer's installation instructions for further detail.
OCR20001 FL34539 Page 1 of 3
This evaluation report is provided for State of Florida product approval under Rule 611320-3. The manufacturer shall notify CREEK
Technical Services,LLC of any product changes or quality assurance changes throughout the duration for which this report is valid.
This evaluation report does not express nor imply warranty, installation, recommended use,or other product attributes that are not
specifically addressed herein.
BEACON SALES ACQ JISITIONS,INC.
�,_�, ' c/o OWENS COR1\UNG ROOFING AND ASPHALT LLC
i9I(Ca L /Iczs�LUC TRMWiLVGramdwUrAwkVnemj
APPUCATION
Roof Deck: The roof deck shall be constructed of,closely fitted Plywood sheathing for new or
existing construction- Deck small be installed in accordance wrath FBC
requirements. Roof decks shot.have no more than 11/8"gap at abutting taints.
iV m slope- 2:12 or in accordance in with:IFBC
Application: Prior to beginning installation, the undedayment shall be unrolled and allowed to
relax for a minimum of 3-5 minufes. The underlayment installation shall comply
with FBC Table 15071.1.1.
The undedayment shalt be installed vfth the roll length parallel to the eave,starting
at the eave fold the undedayment away frown eave onto itseti The undedayment
shall be installed direct-to-decoking with the lower reuse backer removed and
pressed firmly into place to ensure complete contact with the deck. Repeat with
upper release backer_ Overlap successive courses vith minimum 3"side laps and
minimum 6"staggered end laps.
In sleep-slope applications (>6:12),it is pennissible to nail the undedayment 12-
inches on-center as needed(nags shall be installed perpendicular to deck with the
nail heads flush to the top surface of the undedayment).
For valley applications,the roll shall be applied centered along the valley prior to
installing the undedayment at the eave and overlapped a minimum of 6-inches-
For eave protection, the undedayment should extend to a poirnt'8-inches beyond
the interior wall.
Km.Application Temperature: 40°F; Contact the manufacturer when installing at temperatures below the
minimum application temperature.
Aliowab4e roof coverings: Mechanical attachment of asphalt shingles and slate shingles shall be permitted in
accordance with the FBC.
OCR20001 FL34539 Page 2 of 3
This evaluation report is provided for State of Florida product approval under Rule 61G20-3. The manufacturer shall notify CREEK
P P P PP fY
Technical Services,LLC of any product changes or quality assurance changes throughout the duration for which this report is valid.
This evaluation report does not express nor imply warranty, installation,recommended use, or other product attributes that are not
specifically addressed herein.
d � P
REEK BEACON SALES ACQUISMONS,INC.
M� C �c/o(OMNS CORNING ROOFING AND ASPHALT JULC
Tl li¢::AIL Smwces,LLC TIR&BUILT Grundw ymesd
STATIONS
1) This evaluation report is not for use in the HVH7-
2) Fire Classification is not within the scope of this evaluation.
3) Wind uplift resistance in not vidthin scope of this evaluation.
4) Installation of the evaluated product shall comply with this report,The FRC,and the manufacturer's published
application instructions. Where discrepancies exist between these sources, the more restrictive and FBC
compliant installation detail shalt preval.
6) Deck substrates shall be clean,dry,and free from any irregularities and debris. AN fasteners in tthe dec k
shall be checked for protrusion and corrected prior to undedayment application.
6) The undedayment may be used as described in other current lFBC product approval documents.
7) Roof coverings shalt not be adhered directly to the widedayinent Roof coverings shall be rnecitanicafly
fastened through the undedayment:to the roof deck.
8) The undedayment shall not be instafi'ed over existing roof coverings.
9) The undedayment shall be installed starting at the eave in horizontal layers such that the laps shed water
from the deck. The rust fayer shall cover the entire bottom edge of the deck. End laps shaft be staggered a
minimum of 244nches from the preceding course.
10) The undedayment shall,be exposed on the roof deck for a maximum duration of 30 days-
11) All products fisted in this report shall be manufactured under a guaRy assurance program in compfance with
Rite 61G20-3.
COMPLIMCE STATMENT
The products evaluated herein by Zachary R Driest, P.E. have demonstrated comphance with the Florida Building
Code,7ti'Edition(2020)as evidenced in the referenced documents submitted by the named manufacturer-
°�� mR- 2020.10.14
�® 74021 = 15:45:22
� w
-04'00'
STATE OF
Zachary R.Priest,P.E.
10 ®R Q 0 �e� Florida Registration No.74021
Organization No.ANE9641
CERZIFiCATION OF INDEPENDENCE
CREEK Technical Services,LLC does not have,nor will it acquire,a financial interest in any company manufacturing or distributing products under this
evaluatiom
CREEK Technical Services,LLC is not owned,operated,or controlled by any company manufacturing or distributing products under this evaluation.
Zachary R.Priest,P.E.does not have,nor will acquire,a financial interest in any company manufacturing or distributing products under this evaluation.
Zachary R.Priest,P.E.does not have,nor will acquire,a financial interest in any other entity involved in the approval process of the product
END OF REPORT
OCR20001 FL34539 Page 3 of 3
This evaluation report is provided for State of Florida product approval under Rule 61G20-3. The manufacturer shall notify CREEK
Technical Services,LLC of any product changes or quality assurance changes throughout the duration for which this report is valid.
This evaluation report does not express nor imply warranty,installation, recommended use, or other product attributes that are not
specifically addressed herein.