Loading...
HomeMy WebLinkAboutAPPROVED Johnson job-Spanish river jobI I ! i ,.£;;! 0_1 ,... ~· ul I I I l ~ I / I \ IN \tf,l 1 .5 X -z o0 l tl\ (j,jQQ~ i I 1 "' <;. X. ? ,i.)Q:. £'\',; _..$ s:: _t ~ ,".l )< u. <l f z ,-~ I ,/ I t L. ~ 1 !'> :P, :2 J<'.'3 l q' :P 3 l :1 ?if Q.~%, PURLIN SUPPORT COLUMN/POST 2x2x1/8" x 2" LG. ANGLE W/ (4) #12x3/4" S.M.S (EACH SIDE) S.M.S. WITH MIN. ¾," EDGE DISTANCE 0 0 0 0 3" MIN. (1YP.)----1----' ¾, "¢ CONCRETE ANCHOR W/2¾," EMBEDMENT INTO STRUCTURAL CONCRETE (EACH SIDE) SIDEWALL COLUMN TO CONCRETE CONNECTION DETAIL SEE PLAN FOR SIZE 1 x2 0.8. FASTENED TO CORNER SECTION WITH #14x1½'' S.M.S.@ 24" o.c. 2x2x}f," ANGLE 2" LONG (EACH SIDE) W/(2) #14x¾" S.M.S. TO POST & 3/8"¢ H.D. GALV. EXP. BOLT W/ 2 1 /2" MIN. EMBEDMENT CORNER POST/COLUMN TO CONCRETE CONNECTION DETAIL S.M.S. WITH MIN. ¾," EDGE DISTANCE EDGE OF CONCRETE }(," ANGLE, EACH SIDE (1YP.) ¾,"¢ CONCRETE ANCHOR W/2¾," EMBEDMENT INTO STRUCTURAL CONCRETE (1YP., SEE NOTE 10) ( 1 "x2" O.B. SOLE PLATE . z '-'-=-=----Lg ¼"¢x2¼" CONCRETE SCREW ANCHOR @ 24" O.C. AND 9" FROM POST (1YP.) --+--'--!' <TYP.> • zru� PLAN VIEW MAIN COLUMN TO CONCRETE CONNECTION DETAIL EDGE OF CONCRETE .Ji," ANGLE, EACH SIDE (1YP.) ¾,"¢ CONCRETE ANCHOR W/2¾," EMBEDMENT INTO STRUCTURAL CONCRETE (1YP., EE NOTE 10) 1 "x2" O.B. SOLE PLATE . z ,_:_�=---___]_g ¼"¢x2)f' CONCRETE SCREW ANCHOR @ 24" O.C. AND 9" FROM POST (1YP.) 1 x2 0.8. SOLE PLATE :... 2"x PURLIN BEAM MAY BE FLAT OR SLOPED BEAM PLAN -TYPICAL DIAGONAL ROOF BRACE CONNECTION 2x2x½," ANGLE CLIP. CUT AT A 45" (+/-) ANGLE AND ATTACHED TO THE SCREEN ROOF BEAM WITH ONE (1) ¼"¢ THRU­BOLT, WITH FENDER WASHER. ATTACHED TO BEAM OR EAVE RAIL. DIAGONAL BRACING SHALL NOT BE ATTACHED TO ROOF PURLINS. 2x2x0.093 BRACE (SEE PLAN) _-+-_,___ 1' <TYP.) . z ru� PLAN VIEW BEAM SUPPORT COLUMN/POST 2x2x1/8" x 2" LG. ANGLE W/ (4) #12x3/4" S.M.S (EACH SIDE) POST � COLUMN 2½" MAX. THICK BRICK PAVERS SET IN MORTAR ON TOP OF FOOTER 0.8. SOLE PLATE : .... ·.. .... · .... .-,I . . . . . '!· . . .. . .4 •. .-.•. • . · .. �--··. ·. · . _ ........ .;. ....•. · .... � ,a. -',4--: ··" . _...... �--. . ... · . : '. . .. ¼" ¢x5" CONCR�E SCREW�· : 0 2: .. , . O.C.: �2¾," �IN: CONC. (1YP.), 1½" CONG. EMBEDMENT (MIN.) EMBEDMENT (1YP.) TYPCIAL FRONT VIEW OF POST TO FOUNDATION CONNECTION WITH PAVERS .•. <I B'(MIN.) '4. ., ... 4" NOMINAL CONCRETE SLAB (3000 PSI, MIN.) W/6x6x10/10 W.W.M. OR FIBER REINFORCED [POLYPROPYLENE FIBER -1.5 POUND (MIN.)PER C.Y.] .... ., 4 ., �UNDISTURBED SOIL OR COMPACTED CRUSHED LIMEROCK (90% PROCTOR) MIN. ( 1 )-#5 REBAR CONTINUOUS, SPLICE MUST OVERLAP 20" MIN. 3" COVER (1YP.) FOUNDATION/SLAB □ET AIL . N 1 x3 O.B. FASTENED TO CORNER SECTION WITH #1 Ox2" S.M.S. W/ % " DIA. WASHER @ 18" O.C. 2x5x)(,• ANGLE (2' LONG) IJ/ (2)-#14 / TEKS INT□ TOP □F 2x3 EAVE RAIL AND (2)-/ #14 TEKS INT □ THE FRONT □F THE CORNER POST 1 x2 O.B. TOP FRAME 1 x O.B. SIDE WALL CORNER UPRIGHT ELEVATION VIEW CORNER POST/COLUMN UPRIGHT DETAIL APPROXIMATE GRA . 4 . _ . ., ITT .j 1::=- 3000 PSI MIN. CONCRETE STRENGTH 1! 1i�COMPACTED OR 11 UNDISTURBED SOIL/SAND (1)-#5 REBAR, CONTINUOUS 3" MIN. CONC. COVER, 36" MIN. LAP SPLICE 12" MIN.• MIN. CONTINUOUS PERIMETER FOOTING (4) #12x¾" S.M .. 2"x PURLIN BEAM MAY BE FLAT OR SLOPED (2) #1 OxY2" S.M.S . (1YP. EACH END) PLAN -TYPICAL ROOF BRACE TO BEAM CONNECTION 1 2x1xY," ANGLE BRACE 2"x1 "x}(," ANGLE (BRACE) W/ (4) #12x¾" S.M.S. @ EACH MEMBER INTERSECTION 2x2"'1," ANGLE 2" LONG ON UNDERSIDEW/(4) #12x¾" S.M.S. EACH LEG (BEAM & BRACE) 2x3 BRACE (SEE PLAN) AL TERNA TE (2) 2x3 BRACE DD KIM & ASSOCIATES, LLC CONSULTING STRUCTURAL ENGINEERS PO Box 10039 Tampa, FL 33679 Tel: (813) 374-0321 Rev./Date Description Cl) ...J � () UJ C: 0 UJ c:i 0:: l) Cl) C: 0 Q.) ...J Q.) (.) ,._ z CJ) UJ,._ z Q.) UJ Q.) UJC: z 0::0 0 (.) a: I-Cl) i:-.: 0:::: ...J z l) (.) CJ) 0:: ....J w l) 0 I- DRAWN BY: DYK CHECKED BY: DYK SCALE: AS SHOWN DATE: 8/11/06 DO YEON KIM, P.E. FLA. REG. NUMBER 49497 DO KIM & ASSOCIATES, LLC CA#26887 PO Box 10039 Tampa, FL 33679 Drawing No. -060811 SHEET 2 OF 3 (4) #14x3/4" S.M.S. (TYP.) S.M.B. BEAM (3) #14x¾• S,M,S, <TYP, EACH STRAP AND EACH SIDD 1 x2 0.8. lx5x)i,• ANGLE 4' LONG <TYP. @ EACH BEAM) #14x4' S,M,S, vi/ 1¼'¢ FENDER vlASHER AND NEOPRENE GASKET @ 12' □,C, SEALANT #14x½,' SMS vi/ INTEGRAL ¾'!!! vlASHER AND NEOPRENE GASKET TOP & #14x)f( SMS BOTTOM, @ 12• □.C, <COMPOSITE ROOF) SLOPE COMPOSITE PANEL (SEE PLAN FDR SIZD <3>-'l(,•¢ THROUGH BOLT vi /1¾"0 vlASHER (DR) SEALANT 2x2xlf," ANGLE, EACH SIDE (TYP.) ,---,,-.. __ S,M,B, BEAM (8) #14x3/4" S.M.S., 4 SCREWS EACH LEG (TYP.) 3x3x0.050 MIN. PLATE W/ (3) #14x¾" S.M.S. INTO BEAM AND COLUMN (TYP.) 3x3x0.093 POST (MIN.) <6> 1114x¾• S.M,S, TOTAL, (3) EACH LEG ¾,• MIN, C-C SPACING <TYP,) 3• BASE INSERT vi 11�• VERTICAL LEGS )(,• THICK 6063-T6 ALLOY <TYP,) (2) 'Ji!•¢ STAINLESS STEEL DR HOT DIPPED GALVANIZED C□NC. ANCHORS vi/ 2¼' MIN, EMBEDMENT INT□ CONCRETE, (SEE NOTE 10) TOP OF CONCRETE >- WU l.'.lz n.: "'1 <[ Wr->- (/) t; �"' SCREEN ROOF TO PANEL/ COMPOSITE COLUMN TO FOUNDATION CONNECTION DETAIL (SEE PLAN FDR SIZD 3x3x0.093 POST <MIN,) 1114xlf,• S.M,S. vi/INTEGRAL ¾'!!! vlASHER AND NEOPRENE GASKET TOP & 1114xli,' S,M,S. BOTTOM, @ 12' □.C, IF CLEARANCE PROHIBITS INSTALLATION □F TOP FASTENERS USE 1114 S.M.S, @ 12• □.C. CDMPLETEL Y THROUGH COMPOSITE R□□F, SCREEN ROOF TO COMPOSITE ROOF CONNECTION DETAIL 1110x4' S,M,S, vi/ 1¼'0 FENDER vlASHER AND NEOPRENE GASKET @ 12• □,C. 3• COMPOSITE R□□F PANELS (4) #10x2" S.M.S. THRU. UPRI INTO EAVE RAIL/HEADER SCREW BOSSES COMPOSITE ROOF TO HOLLOW SIDE WALL HEADER CONNECTION DETAIL \__ S□FFIT HOST STRUCTURE <MASONRY DR vl□□D> EXTRUDED DR BRAKE-FORMED ROOF HEADER DR RECEIVING CHANNEL (0,044' MIN, THICKNESS) vl!TH MIN, !Ji,' BEARING LEG, General Notes and Specifications: 1. Contractor shall field verify all dimensions before construction and shall notify engineer of discrepancies for immediate consideration. 2.Concrete shall be mi nimum 28 day compressive strength of f'c=2500 psi, and be in acc,ordance with the requirements of A(I 318. Reinforcing steel shall have a min. yield strength of 40,000 psi (grade 40) and be provided with cover in accordance with A[I 318. 3. All dimensions are provided by contractor, DO Kim & Associates, LL( have made interpretations where necessary. 4.The following st ructures are designed to be attached to block and wood frame structures of adequate structural capacity. The contractor shall verify that the host structure is in good condition and of sufficient strength to hold the proposed addition. If there is a question about the host structure, the owner (at his own expense) shall hire an architect or engineer to verify host structure capacity. 5. Screen density shall be a maximum of 18 x 14 x 0.013" mesh. Aluminum shall be 7005-T53 Alloy, 6005-TS Alloy; for secondary components 6063-T6, Alloy based on industry standard shapes. thicknesses, and tolerances unless otherwise noted. 6.Unless otherwise noted, SMB shall be stitched with #10x3/4" SMS at 24"o.c., top and bottom. 7. Connections using screw bosses shall have minimum (4)-#10x2" per connection unless shown otherwise. 8.Unless otherwise shown, screws shall have minimum edge distance and center-to-center distances as shown in this table. C-1022 Low Carbon Steel SMS & Self-Drilling (TEK) Screws (Industry Standard Screws) Nominal Screw Diameter Minimum Edge Distance Minimum Center to Center Screw linl Distance #10 0.188 'I .,, ..½" #12 0.219 'le"'l,t #14 (1/4") 0.250 ½" 'lo" 9.Structure has been designed to meet the 7" Edition FBC (2020 FBCl. Project is sited where the ultimate design wind speed, Vult, is 150 mph (3-sec gust) for risk category I buildings and other structures. Exposure C. Design pressures are from Table 2002.4, 2020 FBC reduced by 0.88 for screen mesh factor, 0.6 for allowable stress design (AS□). 10.Concrete anchors may be "Large Diameter Tapcons" (L TOs). Tapcon concrete screws, Simpson Strong-Tie Anchors or Titian Screws or approved equal. 11.Aluminum roof pans shall be of aluminum alloy 3105-H14 or 3105-H28. Composite panel skins shall be of aluminum alloy 3105-H15 or 3105-H25. DD KIM & ASSOCIATES, LLC CONSULTING STRUCTURAL ENGINEERS PO Box 10039 Tampa, FL 33679 Tel: (813) 374-0321 Rev./Date Description Cl) ...J () C: UJ c:i 0:: l) Cl) C: 0 Q,) ...J Q,) (.) L.. z(.) UJCJ) L.. z Q,) UJ Q,) UJC: z 0::0 0 (.) a: I-Cl) i:-.: 0:::: ...J z l)(.) CJ) C: _J w � l) 0 DRAWN BY: DYK CHECKED BY: DYK SCALE: AS SHOWN DATE: 8/11/06 DO YEON KIM, P.E. FLA. REG. NUMBER 49497 DO KIM & ASSOCIATES, LLC CA#26887 PO Box 10039 Tampa, FL 33679 Drawing No. -060811 SHEET 3 OF 3