Loading...
HomeMy WebLinkAboutAPPROVED Wind Load (2)Propeqy Information I Building Information Owner: Kevin Garbers Wind Zone: 160 MPH. Address: 7201 Arthurs Rd f Exposure Category: C Ft. Pierce. FL 34951 Minimum Building Dimension: 30 ft, Mean Roof Height: 17 R. Risk Category: 11 Design Pressure Calculations Opening Location ;:r,zx;:-:_wi..,ra Device - .eevaw?nmsscemx Device C mHxwvx Device ax Positive MNegative Number Zone Width (in) Height (in) JF--�ax Elevation (ft) Pressure (pst) Pressure (psf) 1 End 36 38 7 34.4 -46.0 2 End 7 34.4 -46.0 3 End 26 62 7 34.1 -45.5 4 End 26 62 7 34.1 -45.5 5 Int 26 62 7 34.1 -37.0 6 Int 52 14 7 34.4 -37.3 7 Int 7 34.4 -37.3 8 Int 7 34.4 -37.3 9 Int 7 34.4 -37.3 10 Int 37 18 7 34.4 -37.3 11 End 26 62 7 34.1 -45.5 12 End 26 62 7 34.1 -45.5 13 Int 7 34.1 -45.5 14 Int 112 62 7 30.9 -33.8 15 Int 7 30.9 -33.8 Prepared in accordance with: ASCE 7-16, Chapter30. Wind Loads - Components and Cladding. 71h Edition (2020) Florida Building Code. Page 1 of 1