HomeMy WebLinkAboutAACE 21-185 10525 S.OCEAN DR CMT REPORTS 061521ANDERSEN ANDRE CONSULTING ENGINEERS, INC.
834 SW Swan Avenue
Port St. Lucie, Florida 34983
Phone: 772-807-9191 Fax: 772-807-9192
www.aaceinc.com
FIELD DENSITY TEST REPORT
PROJECT: 10525 S. Ocean Drive - Building Addition
FILE NO: 21-185
St. Lucie County, Florida
REPORT NO: 1
REPORTED TO: Sweet Industries
PERMIT NO:
CC:
DATE OF TEST(S): 6/7/2021
PAGE NO:
1 OF 1
TEST NO.
12" Compacted Floor Slab Subgrade
MDR
MOISTURE
DENSITY
PERCENT
DEPTH
NO.
CONTENT (%)
COMPACTION
LOCATION
(PCF)
1
26'W from EOP, 5'N from edge of existing concrete
4345
9.1
102.6
97
0 to -12" FS
2
1 VW from EOP, 11'N from edge of existing concrete
4345
8.9
102.0
96
0 to -12" FS
3
18'W from EOP, 3'N from edge of existing concrete
4345
7.8
102.3
96
0 to -12" FS
4
21'W from EDP, 6'N from edge of existing concrete
4345
8.4
103.1
97
0 to -12" FS
* DENOTES IN -PLACE DENSITY TEST DOES NOT MEET MINIMUM COMPACTION REQUIREMENT OF 95 PERCENT.
** RETEST INDICATED DENSITY MEETS OR EXCEEDS MIN. DENSITY REQUIREMENTS
PER SPECIFICATIONS
FIELD TEST: ASTM D-2937 r7;, ASTM D-6938 r ASTM D-2167
r7 ASTM D-1556
TECHNICIAN: MM
REMARKS:
LABORATORY MOISTURE -DENSITY RELATIONSHIP
F = SOIL DIRECTLY BELOW FOOTING
FS = FLOOR SLAB SUBGRADE
OPTIMUM
GA = SOIL IN GENERAL COMPACTED
AREA PAV = SOIL BELOW STABILIZED SECTION
ASTM MAX.
MDR NO. TEST METHOD DENSITY MOISTURE
PSSG = STABILIZED SUBGRADE
PB = PAVEMENT BASE
CONTENT
RS = ROADWAY
NSSG = NON STABILIZED SUBGRADE
4345 D1557 106.1 PCF 10.5 %
SBP = SOIL BELOW PAVEMENT
TOP = TOP OF PIPE
4346 D1557 100.2 PCF 11.0 %
BOP = BOTTOM OF PIPE
BOS = BOTTOM OF STRUCTURE
OTHER:
//�
i
David P. `dr P1rE VU
53969
Fla. Reg.=;).'% 169 * i
AS A MUTUAL PROTECTION TO CLIENTS, THE PUBLIC AND OURSELVES, ALL REPORTS ARE SUBMITTED AS THE CONFIDENTIAL PROPER' ':i 4TS AIR ION
FOR PUBLICATION OF STATEMENTS, CONCLUSIONS OR EXTRACTS FROM OR REGARDING OUR REPORTS IS RESERVED PENDING'. j .clf� EN.APPROVAL.
ANDERSEN ANDRE CONSULTING ENGINEERS, INC.
834 SW Swan Avenue
Port St. Lucie, Florida 34983
Phone: 772-807-9191 Fax: 772-807-9192
www.aaceinc.com
FIELD DENSITY TEST REPORT
PROJECT: 10525 S. Ocean Drive - Building Addition
FILE NO: 21-185
St. Lucie County, Florida
REPORT NO: 2
REPORTED TO: Sweet Industries
PERMIT NO:
CC:
DATE OF TEST(S): 6/11/2021
PAGE NO:
1 OF 1
TEST NO.
12" Compacted Footing Subgrade
MDR
MOISTURE
DENSITY
DRY
PERCENT
DEPTH
NO.
CONTENT (%)
COMPACTION
LOCATION
(PCF)
1
7'N and 2'E from edge of (cut) concrete, in footing
4346
11.0
99.8
100
0 to -12" F
2
2'S and 12'E from edge of (cut) concrete, in footing
4346
10.3
97.6
97
0 to -12" F
3
6'N and 8'W from edge of (cut) concrete, in footing
4346
10.6
96.4
96
0 to -12" F
4
4'N and 13'W from edge of (cut) concrete, in footing
4346
10.4
100.2
100
0 to -12" F
5
9'S and 14'E from edge of (cut) concrete, in footing
4346
11.1
97.3
97
0 to -12" F
* DENOTES IN -PLACE DENSITY TEST DOES NOT MEET MINIMUM COMPACTION REQUIREMENT OF 95 PERCENT.
** RETEST INDICATED DENSITY MEETS OR EXCEEDS MIN. DENSITY REQUIREMENTS
PER SPECIFICATIONS
FIELD TEST: ASTM D-2937 fy—ASTM D-6938 ; ASTM D-2167
ASTM D-1556
TECHNICIAN: MM
REMARKS:
LABORATORY MOISTURE -DENSITY RELATIONSHIP
F = SOIL DIRECTLY BELOW FOOTING
FS = FLOOR SLAB SUBGRADE
OPTIMUM
GA = SOIL IN GENERAL COMPACTED
AREA PAV = SOIL BELOW STABILIZED SECTION
ASTM MAX.
MDR NO. TEST METHOD DENSITY MOISTURE
PSSG = STABILIZED SUBGRADE
PB = PAVEMENT BASE
CONTENT
RS = ROADWAY
NSSG = NON STABILIZED SUBGRADE
4345 D1557 106.1 PCF 10.5 %
SBP = SOIL BELOW PAVEMENT
TOP = TOP OF PIPE
4346 D1557 100.2 PCF 11.0 %
BOP = BOTTOM OF PIPE
BOS = BOTTOM OF STRUCTURE
OTHER:
D 1 p
i LICE..l
David P. And`.
Fla. Reg. Nz 3 9" Ho S3
86
AS A MUTUAL PROTECTION TO CLIENTS, THE PUBLIC AND OURSELVES, ALL REPORTS ARE SUBMITTED AS THE CONFIDENTIAL PROPERTY =C~ fS AND AUTHOFWATION
FOR PUBLICATION OF STATEMENTS, CONCLUSIONS OR EXTRACTS FROM OR REGARDING OUR REPORTS IS RESERVED PENDING OF7� T7EN A
r
t�' iFOF
++m
i ���R/DA
®�>// AL� ENG`��'���`
/111111
ANDERSEN ANDRE CONSULTING ENGINEERS, INC.
834 SW Swan Avenue
Port St. Lucie, Florida 34983
Phone:772-807-9191 Fax:772-807-9192
www.aaceinc.com
MOISTURE -DENSITY RELATIONSHIPS
PROJECT: 10525 S. Ocean Drive - Building Addition FILE NO: 21-185
St. Lucie County, Florida REPORT NO: 1
REPORTED TO: Sweet Industries
CC:
125
120
i=
O
O
LL
U
Fa 115
U
Lu
0-
co
106.1
Z 110
O
CURVES OF 100% SATURATION
FOR SPECIFIC GRAVITY EQUAL TO:
H
=
2.65
O 105
2.70
Lu
2.75
H
Z
100
0
95
0 5 10 15 20 25 30 35
MOISTURE CONTENT (PERCENT OF DRY WEIGHT)
SUMMARY OF TEST RESULTS
TEST METHOD:
ASTM Q698 � ASTM D-1557
(STANDARD) (MODIFIED)
MAXIMUM DRY DENSITY
OPTIMUM WATER
CONTENT {%):
10.5
REMARKS:
SAMPLE NO: 4345 SAMPLE LOCATION: Composite sample, on -site stockpile
DESCRIPTION: Dark brown fine sand with clay ,o®iO,11i II1//jj
mlu
DATE SAMPLED: 6/3/2021 BY: KJ e0i ®
DATE TESTED: 6/9/2021 BY: DA /Vp6
David P.-An jP.E 3969 �m
Fla. Reuel k969,9 '� r
AS A MUTUAL PROTECTION TO CLIENTS, THE PUBLIC AND OURSELVES, ALL REPORTS ARE SUBMITTED AS THE CONFIDENTIAL PROPERTY P1F NTS AN20 ORIZATION
FOR PUBLICATION OF STATEMENTS, CONCLUSIONS OR EXTRACTS FROM OR REGARDING OUR REPORTS IS RESERVED PENDING 1�jWAPPRdQ1V/40 N/ ,�C
FDA
ANDERSEN ANDRE CONSULTING ENGINEERS, INC.
834 SW Swan Avenue
Port St. Lucie, Florida 34983
Phone:772-807-9191 Fax:772-807-9192
www.aaceinc.com
MOISTURE -DENSITY RELATIONSHIPS
PROJECT: 10525 S. Ocean Drive - Building Addition FILE NO: 21-185
St. Lucie County, Florida REPORT NO: 2
REPORTED TO: Sweet Industries
CC:
125
120
h
O
O (Ibslft
U_
U
D 115
U
W
a
CURVES OF 100% SATURATION
Z 110 FOR SPECIFIC GRAVITY EQUAL TO:
M
O
a
H
= 2.65
O 105
2.70
W 2.75
H
Z
D
100
95
0 5 10 15 20 25 30 35
MOISTURE CONTENT (PERCENT OF DRY WEIGHT)
SUMMARY OF TEST RESULTS
SUMMARY OF TEST RESULTS
TEST METHOD:
ASTM D-698
ASTM D-1557
SAMPLE NO: 4346 SAMPLE LOCATION: Composite sample of natural in-plaggpAil„
DESCRIPTION: Brown/orangeish brown fine sandNN
DATE SAMPLED: 6/3/2021 BY: KJ 'IN
DATE TESTED: 6/9/2021 BY: DA
DavidZ9. P re;
Fla. RZ. , 539 i
AS A MUTUAL PROTECTION TO CLIENTS, THE PUBLIC AND OURSELVES, ALL REPORTS ARE SUBMITTED AS THE CONFIDENTIAL PROPERTiVJ TEAND RIZATION
FOR PUBLICATION OF STATEMENTS, CONCLUSIONS OR EXTRACTS FROM OR REGARDING OUR REPORTS IS RESERVED PENDING�J lR)ldiaS ® PPROVAL. . i