Loading...
HomeMy WebLinkAboutrevisionOFFICE USE ONLY: DATE FILED: _ REVISION FEE: PERMIT # 2012-0679 RECEIPT # PLANNING & DEVELOPMENT SERVICES BUILDING & CODE REGULATION DIVISION 2300 VIRGINIA AVENUE FORT PIERCE, FL 34982-5652 (772) 462-1553 FAX (772) 4624578 APPLICATION FOR BUILDING PERMIT REVISIONS PROJECT INFORMATION 1. LOCATION/S ADDRESS: AN ROBERTO 2. DETAILED DESCRIPTION OF PROJECT REVISIONS: E-CALCS REVISED TO MATCH WINDOW VALUES 3. CONTRACTOR INFORMATION: STATE of FL REG./CERT. #: ST. LRICIE COUNTY CERT. #: 8898 BUSINESS NAME: Wyaric Building 'Corpora on ADDRESS ERS N 800b South U S Trwy-. I SUite 402 CITY.. Fort St. Lucie STATE: FE ZIP: 3495 PHONE (DAYTIME): - FAX: 772 78-7656 4. OWNER/BUILDER INFORMATION: NAME: Wynne Building Corporation 5. ADDRESS: CITY: PHONE: ARCHITECT/ENGINEER INFORMATION: NAME: BRADEN & BRADEN ADDRESS: 417 COCONUT AVE.--- STATE: FL ZIP: CITY: STUART STATE: FL ZIP: PHONE (DAYTIME): (772) 287-8258 FAX: Revised 07/22/2014 -� Len FORM R405-2020 FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION Florida Department of Business and Professional Regulation - Residential Performance Method Project Name: WYNNE BUIDLING-THE COTTAGE IMPACT Builder Name: WYNNE BUILDING CORP. Street: THE COTTAGE -A--5 /z:' Permit Office: ST. LUCIE COUNTY City, State, Zip: FT. PIERCE, FL, Permit Number. Owner: WYNNE BUILDING CORP. n Jurisdiction: Design Location: FL, Fort Pierce County: St. Lucie(Florida Climate Zone 2) 1. New construction or existing New (From Plans) 10. Wall Types(1718.3 sqft.) Insulation Area 2. Single family or multiple family Detached a. Concrete Block - Int Insul, ExteriorR=4.1 1478.30 ft2 b. Frame - Wood, Adjacent R=11.0 240.00 ft 3. Number of units, if multiple family 1 c. N/A R= ft2 4. Number of Bedrooms 1 d. N/A R= ft2 5. Is this a worst case? Yes 11. Ceiling Types(1336.0 sqft.) Insulation Area a. Under Attic (Vented) R=30.0 1306.00 ft2 6. Conditioned floor area above grade (ft2) 1306 b. Knee Wall (Vented) R=19.0 30.00 ft2 Conditioned floor area below grade (W) 0 c. N/A R= ft2 7. Windows(128.9 sqft.) Description Area 12. Ducts, location & insulation level R ft2 a. U-Factor: Sgl, U=1.02 76.04 ft2 a. a. Sup: Attic, Ret: Attic, AH: Attic 6 120 SHGC: SHGC=0.29 b. b. U-Factor: Sgl, U=1.03 40.00 ft2 C. SHGC: SHGC=0.27 13. Cooling Systems kBtu/hr Efficiency G. U-Factor: Sgl, U=1.02 12.85 ft2 a. Central Unit 29.0 SEER:14.00 SHGC: SHGC=0.26 Area Weighted Average Overhang Depth: 4.701 ft Area Weighted Average SHGC: 0.281 14. Heating Systems kBtu/hr Efficiency 8. Skylights Description Area a. Electric Heat Pump 27.0 HSPF:8.20 U-Factor(AVG) N/A N/A ft2 SHGC(AVG): N/A 15. Hot Water ems 9. Floor Types Insulation Area a. ElectrcTanklTankless Cap: 1 gallons a. Slab -On -Grade Edge Insulation R= 0.0 1306.00 ft2 EF:0.600 b. N/A R= ft2 b. Conservation features c. N/A R= ft2 None 16. Credits None Glass/Floor Area:0.099 Total Proposed Modified Loads: 41.30 Total Baseline Loads: 43.21 PASS I hereby certify that the plans and specifications covered by Review of the plans and this calculation are in compliance with the Florida Code. Energy specifications covered by this calculation indicates compliance 04'iStE STA;n�, "�' € ?• .� qe with the Florida Energy Code. PREPARED BY: Before construction is completed a ,._��. ,r"' %': to this building will be inspected for a DATE: 6-7-2021 compliance with Section 553.908 Florida Statutes. I hereby certify that this building, as de -compliance with the Florida Energy C OD i1€ OWNER/A, BUILDING OFFICIAL: DATE: \ - Compliance requires certification by the air handler unit manufacturer that the air handler enclosure qualifies as certified factory -sealed in accordance with R403.3.2.1. - Compliance with a proposed duct leakage on requires a PERFORMANCE Duct Leakage Test Report confirming duct leakage to outdoors, tested in accordance with ANSI/RESNET/ICC 380, is not greater than 0.000 Qn for whole house. - Compliance requires an Air Barrier and Insulation Inspection Checklist in accordance with R402.4.1.1 and this project requires a PERFORMANCE envelope leakage test report with envelope leakage no greater than 5.00 ACH50 (R402.4.1.2). 6/7/202111:47:00 AM EnergyGaugeO USA 7.0.00- FlaRes2020 FBC 7th Edition(2020) Compliant Software Pagel FORM R405-2020 INPUT SUMMARY CHECKLIST REPORT PROJECT Title: WYNNE BUIDLING-THE COTTAGE IMPACT Address type: Street Address Building Type: User Bedrooms: 1 Lot#: - Owner: WYNNE BUILDING CORP. Conditioned Area: 1306 Block/SubDivision: Total Stories: 1 PlatBook: Builder Name, WYNNE BUILDING CORP. Worst Case: Yes Street: THE COTTAGE Permit Office: ST. LUCIE COUNTY Rotate Angle: 180 County: St. Lucie Jurisdiction: Cross Ventilation: No City, State, Zip: FT. PIERCE, Family Type: Detached Whole House Fan: No FL, New/Existing: New (From Plans) Terrain: Suburban YearConstruct: Shielding: Suburban Comment: CLIMATE Design Design Temp Int Design Temp Heating Design Daily temp Location Tmy Site 97.5% 2.5% Winter Summer Degree Days Moisture Range FL, Fort Pierce FL_VERO_BEACH_MUNICIPA 39 90 70 75 299 62 Low BLOCKS Number Name Area Volume 1 Entire House 13M76.2001953125 SPACES Number Name Area Volume Kitchen Occupants Bedrooms Finished Cooled Heated _1 MASTER BEDROOM 234 1895A No 0 1 Yes Yes Yes _2 DEN 144 1166.4 No 0 Yes Yes Yes _3 SINKAREA 42 340.2 No 0 Yes Yes Yes _4 CLOSET 63 510.3 No 0 No Yes Yes _5 GREAT ROOM 452 3661.2 No 2 Yes Yes Yes _6 MASTER BATH 50 405 No 0 Yes Yes Yes _7 POWDER 25 202.5 No 0 No Yes Yes _8 KITCHEN 232 18792 Yes 0 Yes Yes Yes _9 LAUNDRY 40 324 No 0 No Yes Yes 10 STORAGE 24 192 No 0 0 Yes Yes Yes FLOORS (Total Exposed Area = 1306 sq.ft.) # Floor Type Space Exposed Perim Perimeter R-Value Area U-Factor Joist R-Value Tile Wood Carpet _ 1 Slab -On -Grade Edge Ins MASTER BEDROOM 31 0 234 It 0.473 - 0.00 1.00 0.00 _2 Slab -On -Grade Edge Ins DEN 24 0 144ft 0.473 - 0.00 1.00 0.00 _3 Slab -On -Grade Edge Ins SINKAREA 7 0 42ft 0.473 - 0.00 1.00 0.00 _4 Slab -On -Grade Edge Ins CLOSET 1 0 63ft 0.473 - 0.00 1.00 0.00 _5 Slab -On -Grade Edge Ins GREAT ROOM 32 0 452ft 0.473 - 0.00 1.00 0.00 _6 Slab -On -Grade Edge Ins MASTER BATH 5 0 50ft 0.473 - 0.00 1.00 0.00 _ 7 Slab -On -Grade Edge Ins POWDER 1 0 25 ft 0.473 - 0.00 1.00 0.00 _8 Slab -On -Grade Edge Ins KITCHEN 38 0 232ft 0.473 - 0.00 1.00 0.00 _9 Slab -On -Grade Edge Ins LAUNDRY 1 0 40 It 0.473 - 0.00 1.00 0.00 10 Slab -On -Grade Edge Ins STORAGE 21 0 24 ft 0.304 - 0.00 0.00 1.00 6/7/2021 11:47:00 AM EnergyGauge® USA 7.0.00 - FlaRes202O FBC 7th Edition (2020) Compliant Software Page 2 FORM R405-2020 INPUT SUMMARY CHECKLIST REPORT ROOF Roof Gable Roof Red Solar SA Emitt Emitt Deck Pitch V# Type Materials Area Area Color Barr Absor. Tested Tested Insul. (deg) 1 Hip Metal 1376 W 0 W Light N 0.6 No 0.9 No 0 18.4 ATTIC # Type Ventilation Vent Ratio (1 in) Area RBS IRCC 1 Full attic Vented 150 1306 ft2 N N CEILING (Total Exposed Area = 1336 sq.ft.) # Ceiling Type Space R-Value Ins. Type Area U-Factor Framing Frac. Truss Type _ 1 UnoerAttic(Vented) MASTER BEDROOM 30.0 Blown 234.Oft2 0.053 0.10 Wood _2 UnderAtfic(Vented) DEN 30.0 Blown 144.0W 0.053 0.10 Wood _3 UnderAttiC(Vented) SINK AREA 30.0 Blown 42.0ft2 0.053 0.10 Wood _4 UnderAttic(Vemed) CLOSET 30.0 Blown 63.Oft2 0.053 0.10 Wood _5 UnderAttic(Vented) GREAT ROOM 30.0 Blown 452.0ft2 0.053 0.10 Wood _6 UnderAtUc(Vented) MASTER BATH 30.0 Blown 50.Oft2 0.053 0.10 Wood _7 UnderAttic(Vemed) POWDER 30.0 Blown 25.Oft2 0.053 0.10 Wood _8 UndefAttic(Vented) KITCHEN 30.0 Blown 232.Oft2 0.053 0.10 Wood _9 UnderAttic(Vented) LAUNDRY 30.0 Blown 40.Oft2 0.053 0.10 Wood _ 10 UnderAttic(Vented) STORAGE 30.0 Blown 24.0f 2 0.030 0.11 Wood 11 Knee Wall(Vented) GREAT ROOM 19.0 Blown 30.0ft2 0.045 0.11 Wood WALLS (Total Exposed Area = 1718 sq.ft.) Note: First wall orientation below is as entered. Actual orientation is modified by the rotate angle (180 degrees) as shown in the "Project" section on page 1. / Adjacent Cavity Width Height Area U- Sheath Frm. Solar Below �/ # Omt TO Wall Type Space R-Value Ft In Ft In sq.ft. Factor R-Value Frac. Absor. Grade _ 1 S=>N Exterior Conc. Blk- Int Ins MASTER BEDROOM 4.1 18.0 0 8.0 1 145.5 0.149 0 0 0.30 0% _2 W=>E Exterior Conc. Elk- Int Ins MASTER BEDROOM 4.1 13.0 0 8.0 1 105.1 0.149 0 0 0.30 0% _ 3 N=>S Exterior Conc. Elk - Int Ins DEN 4.1 12.0 0 8.0 1 97.0 0.149 0 0 0.30 0% _4 W=>E Exterior Conc. Blk -Int Ins DEN 4.1 12.0 0 8.0 1 97.0 0.149 0 0 0.30 0% _5 S=>N Exterior Conc. Elk -Int Ins SINKAREA 4.1 7.0 0 8.0 1 56.6 0.149 0 0 0.30 0% _6 N=>$ Exterior Conc. BIk- Int Ins GREAT ROOM 4.1 22.0 0 8.0 1 177.8 0.149 0 0 0.30 0% _7 W=>E Exterior Conc. BIk- Int Ins GREAT ROOM 4.1 10.0 0 8.0 1 80.8 0.149 0 0 0.30 0% _ 8 S=>N Exterior Conc. Elk - Int Ins MASTER BATH 4.1 5.0 0 8.0 1 40.4 0.149 0 0 0.30 0% _9 N=>S Exterior Conc. Elk - Int Ins KITCHEN 4.1 17.0 0 8.0 1 137.4 0.149 0 0 0.30 0% _ 10 E=>W Exterior Conc. Elk - Int Ins KITCHEN 4.1 16.0 0 8.0 1 129.3 0.149 0 0 0.30 0% _ 11 S=>N Exterior Conc. BIk - Int Ins KITCHEN 4.1 5.0 0 8.0 1 40.4 0.149 0 0 0.30 0% _ 12 N=>S Exterior Conc. Elk - Int Ins KITCHEN 4.1 35.0 0 8.0 1 282.9 0.149 0 0 0.30 0% _ 13 N=>S Exterior Conc. Elk - Int Ins STORAGE 4.1 6.0 0 8.0 0 48.0 0.149 0 0 0.30 0% _ 14 N=>S Exterior Conc. Elk - Int Ins STORAGE 4.1 5.0 0 8.0 0 40.0 0.149 0 0 0.30 0% 15 N=>S Garage Frame - Wood MASTER BEDROOM 11.0 30.0 0 8.0 0 240.0 0.092 0 0.23 0.30 0% DOORS (Total Exposed Area = 20 sq.ft.) Width Height V# Omt Adjacent To Door Type Space Storms U-Value Ft In Ft In Area 1 E=>W Insulated KITCHEN None 0.32 3.00 0 6.00 8 20.Oft2 6/7/2021 11:47:00 AM EnergyGaugeO USA 7.0.00 - FlaRes2020 FBC 7th Edition (2020) Compliant Software Page 3 FORMR405-2020 INPUT SUMMARY CHECKLIST REPORT WINDOWS (Total Exposed Area = 129 sq.ft.) / Wall -Overhang- / # Ornt ID Frame Panes NFRC U-Factor SHGC Imp Storm Area Depth Separation Interior Shade Screening -1 W=>E 2 Metal Low-E Single Yes 1.02 0.29 N N 32.411' 1.0 ft 5 in 1.0 ft 5 in None None _2 W=>E 4 Metal Low-E Single Yes 1.02 0.29 N N 18.4ft2 1.0 ft 5 in 1.0 ft 5 in None None _ 3 N=>S 6 Metal Low-E Single Yes 1.02 029 N N 18.4ft2 1.0 ft 5 in 1.0 ft 5 in None None _4 W=>E 7 Metal Low-ESingle Yes 1.03 0.27 N N 40.01`12 12.0 ft0 in 1.0 ft5 in None None -5 S=>N 8 Metal Low-E Single Yes 1.02 0.29 N N 6.9f 2 1.0 ft 5 in 1.0 ft 5 in None None 6 E=>W 10 Metal Low-E Single Yes 1.02 0.26 N N 12.8ft2 1.0 ft 5 in 1.0 ft 5 in None None INFILTRATION # Scope Method SLA CFM50 ELA EgLA ACH ACH50 Space(s) 1 Wholehcuse Proposed ACH(50) 0.00026 881 48.35 90.78 0.0907 5.0 All GARAGE # FloorArea Roof Area Exposed Wall Perimeter Avg. Wall Height Exposed Wall Insulation 1 280 ft2 280 ft2 35 ft 8 ft 11 MASS # Mass Type Area Thickness FumitureFraction Space _ 1 Default(8lbs/sq.ft.) 0 ft2 0 ft 0.30 MASTER BEDROOM _2 Default(8lbs/sq.ft.) Oft' Oft 0.30 DEN _3 Default(8lbs/sq.ft.) Oft' Oft 0.30 SINKAREA -4 Default(8lbs/sq.ft.) 0 ft2 0 ft 0.30 CLOSET -5 Default(8lbs/sq.ft.) Oft 0 It 0.30 GREAT ROOM _ 6 Default(81bs/sq.fL) 0 ft2 0 It 0.30 MASTER BATH _7 Default(8lbs/sq.ft.) Oft' Oft 0.30 POWDER _8 Default(8lbs/sq.ft.) 0ft2 Oft 0.30 KITCHEN _9 Default(8lbs/sq.ft.) Oft' Oft 0.30 LAUNDRY 10 Default(8lbs/sq.ft.) 0 ft2 Oft 0.30 STORAGE HEATING SYSTEM # System Type Subtype/Speed AHRI # Efficiency Capacity -Geothermal HeatPump- Ducts Block kBtu/hr Entry Power Volt Current 1 Electric Heat Pump Split/Single HSPF: 8.20 27.0 0.00 0.00 0.00 sys#1 1 COOLING SYSTEM # System Type Subtype/Speed AHRI# Efficiency Capacity Air Flow SHR Duct Block kBtu/hr chn 1 Central Unit Split/Single SEER:14.0 29.0 0 0.80 sys#1 1 6/7/2021 11:47:00 AM EnergyGauge® USA 7.0.00 - FlaRes202O FBC 7th Edition (2020) Compliant Software Page 4 FORMR405-2020 INPUT SUMMARY CHECKLIST REPORT HOT WATER SYSTEM # System Type Subtype Location EF(UEF) Cap Use SetPnt Fixture Flow Pipe Ins. Pipe length 1 Electric Tankless Garage 0.60 (0.60) 1.00 gal 61 gal 120 deg Standard None 82 Recirculation Recim Control Loop Branch Pump DWHR Facilities Equal DWHR OtherCredits System Type length length power Connected Flow Eff 1 No NA NA NA No NA NA NA None DUCTS Supply ——Return----- Air CFM 25 CFM 25 HVAC # JDuct # Location R-Value Area Location R-Value Area Leakage Type Handler TOT OUT QN RLF Heat Cool 1 Attic 6.0 120 ft' Attic 6.0 45 ft' Default Leakage Attic (Default) (Default) 1 1 TEMPERATURES Programable Thermostat: N Ceiling Fans: N Cooling [ ] Jan [] Feb [I Mar [ ] Apr [ ] May [X] Jun [X] Jul [X] Aug [X] Sep [ ] Oct [ ] Nov [ ] Dec Heating [X] Jan [X] Feb Pq Mar [ ] Apr [ ] May [ ] Jun [ ] Jul [ ] Aug [ ] Sep [ ] Oct [X] Nov [X] Dec Venting [ ] Jan [] Feb [X] Mar [X] Apr (] May [I Jun []Jul [ ] Aug [ ] Sep [X] Oct (X] Nov [ ] Dec Thermostat Schedule: HERS 2006 Reference Hours Schedule Type 1 2 3 4 5 6 7 8 9 10 11 12 _Cooling(WD) AM 78 78 78 78 78 78 78 78 78 78 78 78 PM 78 78 78 78 78 78 78 78 78 78 78 78 _Cooling(WEH) AM 78 78 78 78 78 78 78 78 78 78 78 78 PM 78 78 78 78 78 78 78 78 78 78 78 78 Heating (WD) AM 68 68 68 68 68 68 68 68 68 68 68 68 PM 68 68 68 68 68 68 68 68 68 68 68 68 _Heating(WEH) AM 68 68 68 68 68 68 68 68 68 68 68 68 PM 68 68 68 68 68 68 68 68 68 68 68 68 6f7/2021 11:47:00 AM EnergyGauge® USA 7.0.00 - FlaRes2020 FBC 7th Edition (2020) Compliant Software Page 5 2020 - AIR BARRIER AND INSULATION INSPECTION COMPONENT CRITERIA TABLE 402.4.1.1 AIR BARRIER AND INSULATION INSPECTION COMPONENT CRITERIAa Project Name: WYNNE BUIDLING-THE COTTAGE IMPACT Builder Name: WYNNE BUILDING CORP. Street: THE COTTAGE Permit Office: ST. LUCIE COUNTY City, State, Zip: FT. PIERCE, FL, Permit Number: Y Owner: WYNNE BUILDING CORP. Jurisdiction: U Design Location: FL, Fort Pierce County: St. Lucie(Florida Climate Zone 2) _ U COMPONENT AIR BARRIER CRITERIA INSULATION INSTALLATION CRITERIA General A continuous air barrier shall be installed in the building envelope. Air-permeableinsulationshall requirements The exterior thermal envelope contains a continuous air barrier. not be used as a sealing material. Breaks orjoints in the air barrier shall be sealed. The air barrier in any dropped ceiling/soffit shall be aligned with The insulation in any dropped ceiling/soffit Ceiling/attic the insulation and any gaps in the air barrier shall be sealed. shall be aligned with the air barrier. Access openings, drop down stairs or knee wall doors to unconditioned attic spaces shall be sealed. Walls The junction of the foundation and sill plate shall be sealed. Cavities within comers and headers of frame walls The junction of the top plate and the top of exterior walls shall be shall be insulated by completely filling the cavity with sealed. a material having a thermal resistance of R-3 per Knee walls shall be sealed. inch minimum Exteriorthermal envelope insulation for framed walls shall be installed in substantial contact and continuous alignment with the air barrier. Windows, skylights The space between window/doorjambs and framing, and anddoors skylights and framing shall be sealed. Rim joists Rim joists shall include the air barrier. Rim joists shall be insulated. Floors The air barrier shall be installed at any exposed edge of Floor framing cavity insulation shall be installed to (including insulation. maintain permanent contact with the underside of above -garage subfloor decking, or floor framing cavity insulation and cantilevered shall be permitted to be in contact with the top side floors) of sheathing, orcontinuous insulation installed on the underside of floor framing and extends from the bottom to the top of all perimeter floor framing members. Crawl space walls Exposed earth in unvented crawl spaces shall be covered Where provided instead of floor insulation, insulation with a Class l vapor retarder with overlapping joints taped. shall be permanently attached to the crawlspace walls. Shafts, penetrations Dud shafts, utility penetrations, and flue shafts opening to exterior or unconditioned space shall be sealed. Narrow cavities Batts in narrow cavities shal I be cut to fit, or narrow cavities shall be filled by insulation that on installation readily conforms to the available cavity spaces. Gawgeseparation Air sealing shall be provided between the garage and conditionedspaces. Recessedlighting Recessed lightfixtures installed in the building thermal Recessed lightfixtures installed in the building envelope shall be sealed to the finished surface. thermal envelope shall be air tight and IC rated. Plumbing and wiring Batt insulation shall be cot neatly to fit around wiring and plumbing in exterior walls, or insulation that on installation readily conforms to available space shal I extend behind piping and wiring. Shower/tub The air barrier installed at exterior walls adjacent to showers Exterior walls adjacent to showers and tubs shall on exteriorwall and tubs shall separate them from the showers and tubs. beinsulated. Electrical/phonebox The air barrier shall be installed behind electrical or on exteriorwalls communication boxes orair-sealed boxes shall be installed. HVAC register boot HVAC supply and return register boots that penetrate building thermal envelope shall be sealed to the sub -floor, wall covering or ceiling penetrated by the boot. Concealed When required to be sealed, concealed fire sprinklers shall only sprinklers be sealed in a manner that is recommended by the manufacturer. Caulking or other adhesive sealants shall not be used to fill voids voids between fire sprinkler cover plates and walls or ceilings. a. In addition, inspection of log walls shall be in accordance with the provisions of ICC-400. 6/7/2021 11:47:00 AM EnergyGauge® USA 7.0 - FlaRes2020 FBC 7th Edition (2020) Compliant Software Page 1 FORM R405-2020 ENERGY PERFORMANCE LEVEL (EPL) DISPLAY CARD ESTIMATED ENERGY PERFORMANCE INDEX* = 96 The lower the EnergyPerformance Index, the more efficient the home. THE COTTAGE,FT. PIERCE,FL, 1. New construction or existing New (From Plans) 2. Single family or multiple family Detached 3. Number of units, if multiple family 1 4. Number of Bedrooms 1 5. Is this a worst case? Yes 6. Conditioned floor area above grade (ft2) 1306 Conditioned floor area below grade (ft2) 0 7. Windows- Description Area a. U-Factor: Sgl, U=1.02 76.04 ft2 SHGC: SHGC=0.29 b. U-Factor: Sgl, U=1.03 40.00 ft2 SHGC: SHGC=0.27 c. U-Factor: Sgl, U=1.02 12.85 ftZ SHGC: SHGC=0.26 Area Weighted Average Overhang Depth: 4.701 ft Area Weighted Average SHGC: 0.281 8. Skylights Description Area U-Factor:(AVG) N/A N/A ft2 SHGC(AVG): N/A 9. Floor Types Insulation Area a. Slab -On -Grade Edge Insulation R= 0.0 1306.00 ft2 b. N/A R= ft2 c. N/A R= ft2 10. Wall Types(1718.3 sqft.) Insulation Area a. Concrete Block - Int Insul, ExteriorR=4.1 1478.30 ft2 b. Frame - Wood, Adjacent R=11.0 240.00 ft2 c. N/A R= ft2 d. N/A R= ft2 11. Ceiling Types(1336.0 sqft.) Insulation Area a. Under Attic (Vented) R=30.0 1306.00 ft2 b. Knee Wall (Vented) R=19.0 30.00 ft2 c. N/A R= ft2 12. Ducts, location & insulation level R ft2 a. a. Sup: Attic, Ret: Attic, AH: Attic 6 120 b. C. 13. Cooling Systems kBtu/hr Efficiency a. Central Unit 29.0 SEER:14.00 14. Heating Systems kBtu/hr Efficiency a. Electric Heat Pump 27.0 HSPF:8.20 15. Hot Water Systems a. ElectricTankless Cap: 1 gallons EF: 0.600 b. Conservation features None 16. Credits None I certify that this home has complied with the Florida Energy Efficiency Code for Building Construction through the above energy saving features which will be installed (or exceeded) in this home before final inspection. Otherwise, a new EPL Display Card will be completed based on installed Code compliant features. Builder Signature: Date: �9 `� \ Address of New Home: THE COTTAGE City/FL Zip: FT. PIERCE,FL, *Note: This is not a Building Energy Rating. If your Index is below 70, your home may qualify for energy efficient mortgage (EEM) incentives if you obtain a Florida Energy Rating. For information about the Florida Building Code, Energy Conservation, contact the Florida Building Commission's support staff. **Label required by Section R303.1.3 of the Florida Building Code, Energy Conservation, if not DEFAULT. 677/2021 11:47:00 AM EnergyGauge@ USA 7.0.00 - FlaRes2020 FBC 7th Edition (2020) Compliant Software Page 1 of 1