HomeMy WebLinkAboutrevisionOFFICE USE ONLY:
DATE FILED: _
REVISION FEE:
PERMIT # 2012-0679
RECEIPT #
PLANNING & DEVELOPMENT SERVICES
BUILDING & CODE REGULATION DIVISION
2300 VIRGINIA AVENUE
FORT PIERCE, FL 34982-5652
(772) 462-1553 FAX (772) 4624578
APPLICATION FOR BUILDING PERMIT REVISIONS
PROJECT INFORMATION
1. LOCATION/S
ADDRESS: AN ROBERTO
2. DETAILED DESCRIPTION OF PROJECT
REVISIONS:
E-CALCS REVISED TO MATCH WINDOW VALUES
3. CONTRACTOR INFORMATION:
STATE of FL REG./CERT. #: ST. LRICIE COUNTY CERT. #: 8898
BUSINESS NAME: Wyaric Building
'Corpora on
ADDRESS ERS N 800b South U S Trwy-. I SUite 402
CITY.. Fort St. Lucie STATE: FE ZIP: 3495
PHONE (DAYTIME): - FAX: 772 78-7656
4. OWNER/BUILDER INFORMATION:
NAME: Wynne Building Corporation
5.
ADDRESS:
CITY:
PHONE:
ARCHITECT/ENGINEER INFORMATION:
NAME: BRADEN & BRADEN
ADDRESS:
417 COCONUT AVE.---
STATE: FL ZIP:
CITY: STUART STATE: FL ZIP:
PHONE (DAYTIME): (772) 287-8258 FAX:
Revised 07/22/2014
-� Len
FORM R405-2020
FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION
Florida Department of Business and Professional Regulation - Residential Performance Method
Project Name: WYNNE BUIDLING-THE COTTAGE IMPACT Builder Name: WYNNE BUILDING CORP.
Street: THE COTTAGE -A--5 /z:'
Permit Office: ST. LUCIE COUNTY
City, State, Zip: FT. PIERCE, FL,
Permit Number.
Owner: WYNNE BUILDING CORP.
n
Jurisdiction:
Design Location: FL, Fort Pierce
County: St. Lucie(Florida Climate Zone 2)
1. New construction or existing New (From
Plans)
10. Wall Types(1718.3 sqft.)
Insulation Area
2. Single family or multiple family
Detached
a. Concrete Block - Int Insul,
ExteriorR=4.1 1478.30 ft2
b. Frame - Wood, Adjacent
R=11.0 240.00 ft
3. Number of units, if multiple family
1
c. N/A
R= ft2
4. Number of Bedrooms
1
d. N/A
R= ft2
5. Is this a worst case?
Yes
11. Ceiling Types(1336.0 sqft.)
Insulation Area
a. Under Attic (Vented)
R=30.0 1306.00 ft2
6. Conditioned floor area above grade (ft2)
1306
b. Knee Wall (Vented)
R=19.0 30.00 ft2
Conditioned floor area below grade (W)
0
c. N/A
R= ft2
7. Windows(128.9 sqft.) Description
Area
12. Ducts, location & insulation level
R ft2
a. U-Factor: Sgl, U=1.02
76.04 ft2
a. a. Sup: Attic, Ret: Attic, AH:
Attic 6 120
SHGC: SHGC=0.29
b.
b. U-Factor: Sgl, U=1.03
40.00 ft2
C.
SHGC: SHGC=0.27
13. Cooling Systems
kBtu/hr Efficiency
G. U-Factor: Sgl, U=1.02
12.85 ft2
a. Central Unit
29.0 SEER:14.00
SHGC: SHGC=0.26
Area Weighted Average Overhang Depth:
4.701 ft
Area Weighted Average SHGC:
0.281
14. Heating Systems
kBtu/hr Efficiency
8. Skylights Description
Area
a. Electric Heat Pump
27.0 HSPF:8.20
U-Factor(AVG) N/A
N/A ft2
SHGC(AVG): N/A
15. Hot Water ems
9. Floor Types Insulation
Area
a. ElectrcTanklTankless
Cap: 1 gallons
a. Slab -On -Grade Edge Insulation R= 0.0
1306.00 ft2
EF:0.600
b. N/A R=
ft2
b. Conservation features
c. N/A R=
ft2
None
16. Credits
None
Glass/Floor Area:0.099 Total Proposed Modified Loads: 41.30
Total Baseline Loads: 43.21
PASS
I hereby certify that the plans and specifications covered by
Review of the plans and
this calculation are in compliance with the Florida
Code.
Energy
specifications covered by this
calculation indicates compliance
04'iStE STA;n�,
"�' € ?• .� qe
with the Florida Energy Code.
PREPARED BY:
Before construction is completed
a ,._��. ,r"' %': to
this building will be inspected for
a
DATE: 6-7-2021
compliance with Section 553.908
Florida Statutes.
I hereby certify that this building, as de
-compliance
with the Florida Energy C
OD i1€
OWNER/A,
BUILDING OFFICIAL:
DATE: \
- Compliance requires certification by the air handler unit manufacturer that the air handler enclosure qualifies as
certified factory -sealed in accordance with R403.3.2.1.
- Compliance with a proposed duct leakage on requires a PERFORMANCE Duct Leakage Test Report confirming duct
leakage to outdoors, tested in accordance with ANSI/RESNET/ICC 380, is not greater than 0.000 Qn for whole house.
- Compliance requires an Air Barrier and Insulation Inspection Checklist in accordance with R402.4.1.1 and this project
requires a PERFORMANCE envelope leakage test report with envelope leakage no greater than 5.00 ACH50 (R402.4.1.2).
6/7/202111:47:00 AM EnergyGaugeO USA 7.0.00- FlaRes2020 FBC 7th Edition(2020) Compliant Software Pagel
FORM R405-2020 INPUT SUMMARY CHECKLIST REPORT
PROJECT
Title: WYNNE BUIDLING-THE COTTAGE IMPACT
Address type:
Street Address
Building Type: User
Bedrooms: 1
Lot#:
-
Owner: WYNNE BUILDING CORP.
Conditioned Area: 1306
Block/SubDivision:
Total Stories: 1
PlatBook:
Builder Name, WYNNE BUILDING CORP.
Worst Case: Yes
Street:
THE COTTAGE
Permit Office: ST. LUCIE COUNTY
Rotate Angle: 180
County:
St. Lucie
Jurisdiction:
Cross Ventilation: No
City, State, Zip:
FT. PIERCE,
Family Type: Detached
Whole House Fan: No
FL,
New/Existing: New (From Plans)
Terrain: Suburban
YearConstruct:
Shielding: Suburban
Comment:
CLIMATE
Design
Design Temp
Int Design Temp
Heating
Design
Daily temp
Location
Tmy Site
97.5% 2.5%
Winter Summer
Degree Days
Moisture
Range
FL, Fort Pierce
FL_VERO_BEACH_MUNICIPA 39 90
70 75
299
62
Low
BLOCKS
Number Name
Area
Volume
1 Entire House
13M76.2001953125
SPACES
Number Name
Area
Volume Kitchen Occupants
Bedrooms
Finished
Cooled
Heated
_1 MASTER BEDROOM
234
1895A No 0
1
Yes
Yes
Yes
_2 DEN
144
1166.4 No 0
Yes
Yes
Yes
_3 SINKAREA
42
340.2 No 0
Yes
Yes
Yes
_4 CLOSET
63
510.3 No 0
No
Yes
Yes
_5 GREAT ROOM
452
3661.2 No 2
Yes
Yes
Yes
_6 MASTER BATH
50
405 No 0
Yes
Yes
Yes
_7 POWDER
25
202.5 No 0
No
Yes
Yes
_8 KITCHEN
232
18792 Yes 0
Yes
Yes
Yes
_9 LAUNDRY
40
324 No 0
No
Yes
Yes
10 STORAGE
24
192 No 0
0
Yes
Yes
Yes
FLOORS
(Total Exposed Area = 1306 sq.ft.)
# Floor Type
Space
Exposed Perim Perimeter R-Value Area U-Factor Joist R-Value
Tile Wood Carpet
_ 1 Slab -On -Grade Edge Ins
MASTER BEDROOM 31 0
234 It 0.473
-
0.00
1.00 0.00
_2 Slab -On -Grade Edge Ins
DEN
24 0
144ft 0.473
-
0.00
1.00 0.00
_3 Slab -On -Grade Edge Ins
SINKAREA
7 0
42ft 0.473
-
0.00
1.00 0.00
_4 Slab -On -Grade Edge Ins
CLOSET
1 0
63ft 0.473
-
0.00
1.00 0.00
_5 Slab -On -Grade Edge Ins
GREAT ROOM
32 0
452ft 0.473
-
0.00
1.00 0.00
_6 Slab -On -Grade Edge Ins
MASTER BATH
5 0
50ft 0.473
-
0.00
1.00 0.00
_ 7 Slab -On -Grade Edge Ins
POWDER
1 0
25 ft 0.473
-
0.00
1.00 0.00
_8 Slab -On -Grade Edge Ins
KITCHEN
38 0
232ft 0.473
-
0.00
1.00 0.00
_9 Slab -On -Grade Edge Ins
LAUNDRY
1 0
40 It 0.473
-
0.00
1.00 0.00
10 Slab -On -Grade Edge Ins
STORAGE
21 0
24 ft 0.304
-
0.00
0.00 1.00
6/7/2021 11:47:00 AM EnergyGauge® USA 7.0.00 - FlaRes202O FBC 7th Edition (2020) Compliant Software Page 2
FORM R405-2020 INPUT SUMMARY CHECKLIST REPORT
ROOF
Roof Gable Roof
Red Solar SA Emitt Emitt
Deck Pitch
V# Type
Materials Area Area
Color
Barr Absor. Tested
Tested
Insul. (deg)
1 Hip
Metal 1376 W 0 W
Light
N
0.6 No 0.9 No
0 18.4
ATTIC
# Type
Ventilation Vent Ratio (1 in) Area
RBS IRCC
1 Full attic
Vented 150
1306 ft2
N
N
CEILING
(Total Exposed Area = 1336 sq.ft.)
# Ceiling Type
Space R-Value
Ins. Type
Area
U-Factor Framing Frac.
Truss Type
_ 1 UnoerAttic(Vented)
MASTER BEDROOM 30.0
Blown
234.Oft2
0.053
0.10
Wood
_2 UnderAtfic(Vented)
DEN 30.0
Blown
144.0W
0.053
0.10
Wood
_3 UnderAttiC(Vented)
SINK AREA 30.0
Blown
42.0ft2
0.053
0.10
Wood
_4 UnderAttic(Vemed)
CLOSET 30.0
Blown
63.Oft2
0.053
0.10
Wood
_5 UnderAttic(Vented)
GREAT ROOM 30.0
Blown
452.0ft2
0.053
0.10
Wood
_6 UnderAtUc(Vented)
MASTER BATH 30.0
Blown
50.Oft2
0.053
0.10
Wood
_7 UnderAttic(Vemed)
POWDER 30.0
Blown
25.Oft2
0.053
0.10
Wood
_8 UndefAttic(Vented)
KITCHEN 30.0
Blown
232.Oft2
0.053
0.10
Wood
_9 UnderAttic(Vented)
LAUNDRY 30.0
Blown
40.Oft2
0.053
0.10
Wood
_ 10 UnderAttic(Vented)
STORAGE 30.0
Blown
24.0f 2
0.030
0.11
Wood
11 Knee Wall(Vented)
GREAT ROOM 19.0
Blown
30.0ft2
0.045
0.11
Wood
WALLS
(Total Exposed Area = 1718 sq.ft.)
Note: First wall orientation below is as entered. Actual orientation is modified by the rotate angle (180 degrees) as shown in the "Project" section on page 1.
/ Adjacent
Cavity
Width
Height
Area U-
Sheath Frm.
Solar Below
�/ # Omt TO
Wall Type
Space R-Value
Ft In
Ft In
sq.ft. Factor
R-Value Frac.
Absor. Grade
_ 1 S=>N Exterior
Conc. Blk- Int Ins
MASTER BEDROOM 4.1
18.0 0
8.0 1
145.5 0.149
0 0
0.30 0%
_2 W=>E Exterior
Conc. Elk- Int Ins
MASTER BEDROOM 4.1
13.0 0
8.0 1
105.1 0.149
0 0
0.30 0%
_ 3 N=>S Exterior
Conc. Elk - Int Ins
DEN 4.1
12.0 0
8.0 1
97.0 0.149
0 0
0.30 0%
_4 W=>E Exterior
Conc. Blk -Int Ins
DEN 4.1
12.0 0
8.0 1
97.0 0.149
0 0
0.30 0%
_5 S=>N Exterior
Conc. Elk -Int Ins
SINKAREA 4.1
7.0 0
8.0 1
56.6 0.149
0 0
0.30 0%
_6 N=>$ Exterior
Conc. BIk- Int Ins
GREAT ROOM 4.1
22.0 0
8.0 1
177.8 0.149
0 0
0.30 0%
_7 W=>E Exterior
Conc. BIk- Int Ins
GREAT ROOM 4.1
10.0 0
8.0 1
80.8 0.149
0 0
0.30 0%
_ 8 S=>N Exterior
Conc. Elk - Int Ins
MASTER BATH 4.1
5.0 0
8.0 1
40.4 0.149
0 0
0.30 0%
_9 N=>S Exterior
Conc. Elk - Int Ins
KITCHEN 4.1
17.0 0
8.0 1
137.4 0.149
0 0
0.30 0%
_ 10 E=>W Exterior
Conc. Elk - Int Ins
KITCHEN 4.1
16.0 0
8.0 1
129.3 0.149
0 0
0.30 0%
_ 11 S=>N Exterior
Conc. BIk - Int Ins
KITCHEN 4.1
5.0 0
8.0 1
40.4 0.149
0 0
0.30 0%
_ 12 N=>S Exterior
Conc. Elk - Int Ins
KITCHEN 4.1
35.0 0
8.0 1
282.9 0.149
0 0
0.30 0%
_ 13 N=>S Exterior
Conc. Elk - Int Ins
STORAGE 4.1
6.0 0
8.0 0
48.0 0.149
0 0
0.30 0%
_ 14 N=>S Exterior
Conc. Elk - Int Ins
STORAGE 4.1
5.0 0
8.0 0
40.0 0.149
0 0
0.30 0%
15 N=>S Garage
Frame - Wood
MASTER BEDROOM 11.0
30.0 0
8.0 0
240.0 0.092
0 0.23
0.30 0%
DOORS
(Total Exposed Area = 20 sq.ft.)
Width
Height
V# Omt Adjacent To Door Type
Space Storms
U-Value
Ft In
Ft In
Area
1 E=>W
Insulated
KITCHEN None
0.32
3.00 0
6.00 8
20.Oft2
6/7/2021 11:47:00 AM EnergyGaugeO USA 7.0.00 - FlaRes2020 FBC 7th Edition (2020) Compliant Software Page 3
FORMR405-2020 INPUT SUMMARY CHECKLIST REPORT
WINDOWS
(Total Exposed Area = 129 sq.ft.)
/ Wall
-Overhang-
/ # Ornt ID Frame
Panes
NFRC U-Factor SHGC Imp Storm Area
Depth Separation Interior Shade Screening
-1 W=>E 2 Metal
Low-E Single
Yes 1.02
0.29 N N 32.411'
1.0 ft 5 in 1.0 ft 5 in None
None
_2 W=>E 4 Metal
Low-E Single
Yes 1.02
0.29 N N 18.4ft2
1.0 ft 5 in 1.0 ft 5 in None
None
_ 3 N=>S 6 Metal
Low-E Single
Yes 1.02
029 N N 18.4ft2
1.0 ft 5 in 1.0 ft 5 in None
None
_4 W=>E 7 Metal
Low-ESingle
Yes 1.03
0.27 N N 40.01`12
12.0 ft0 in 1.0 ft5 in None
None
-5 S=>N 8 Metal
Low-E Single
Yes 1.02
0.29 N N 6.9f 2
1.0 ft 5 in 1.0 ft 5 in None
None
6 E=>W 10 Metal
Low-E Single
Yes 1.02
0.26 N N 12.8ft2
1.0 ft 5 in 1.0 ft 5 in None
None
INFILTRATION
# Scope Method
SLA CFM50 ELA EgLA
ACH ACH50 Space(s)
1 Wholehcuse Proposed ACH(50)
0.00026
881 48.35 90.78
0.0907 5.0 All
GARAGE
# FloorArea
Roof Area
Exposed Wall Perimeter
Avg. Wall Height Exposed Wall Insulation
1 280 ft2
280 ft2
35 ft
8 ft 11
MASS
# Mass Type
Area
Thickness FumitureFraction Space
_ 1 Default(8lbs/sq.ft.)
0 ft2
0 ft
0.30 MASTER BEDROOM
_2 Default(8lbs/sq.ft.)
Oft'
Oft
0.30 DEN
_3 Default(8lbs/sq.ft.)
Oft'
Oft
0.30 SINKAREA
-4 Default(8lbs/sq.ft.)
0 ft2
0 ft
0.30 CLOSET
-5 Default(8lbs/sq.ft.)
Oft
0 It
0.30 GREAT ROOM
_ 6 Default(81bs/sq.fL)
0 ft2
0 It
0.30 MASTER BATH
_7 Default(8lbs/sq.ft.)
Oft'
Oft
0.30 POWDER
_8 Default(8lbs/sq.ft.)
0ft2
Oft
0.30 KITCHEN
_9 Default(8lbs/sq.ft.)
Oft'
Oft
0.30 LAUNDRY
10 Default(8lbs/sq.ft.)
0 ft2
Oft
0.30 STORAGE
HEATING SYSTEM
# System Type
Subtype/Speed
AHRI # Efficiency Capacity -Geothermal HeatPump- Ducts
Block
kBtu/hr Entry Power Volt Current
1 Electric Heat Pump
Split/Single
HSPF: 8.20 27.0 0.00 0.00 0.00 sys#1
1
COOLING SYSTEM
# System Type
Subtype/Speed
AHRI# Efficiency
Capacity Air Flow SHR Duct
Block
kBtu/hr chn
1 Central Unit
Split/Single
SEER:14.0 29.0 0 0.80 sys#1
1
6/7/2021 11:47:00 AM EnergyGauge® USA 7.0.00 - FlaRes202O FBC 7th Edition (2020) Compliant Software Page 4
FORMR405-2020 INPUT SUMMARY CHECKLIST REPORT
HOT WATER SYSTEM
# System Type
Subtype
Location
EF(UEF) Cap Use
SetPnt
Fixture Flow Pipe Ins.
Pipe length
1 Electric
Tankless
Garage
0.60 (0.60) 1.00 gal 61 gal
120 deg
Standard None
82
Recirculation
Recim Control
Loop Branch Pump DWHR
Facilities Equal DWHR
OtherCredits
System
Type
length length power
Connected Flow Eff
1 No
NA NA NA No
NA
NA NA
None
DUCTS
Supply ——Return-----
Air
CFM 25 CFM 25
HVAC #
JDuct
# Location
R-Value Area Location R-Value Area Leakage Type
Handler
TOT OUT QN
RLF Heat Cool
1 Attic
6.0 120 ft'
Attic
6.0 45 ft' Default Leakage
Attic
(Default) (Default)
1 1
TEMPERATURES
Programable Thermostat: N
Ceiling Fans: N
Cooling [ ] Jan
[] Feb
[I Mar
[ ] Apr
[ ] May [X] Jun [X] Jul
[X] Aug
[X] Sep [ ] Oct [ ]
Nov [ ] Dec
Heating [X] Jan
[X] Feb
Pq Mar
[ ] Apr
[ ] May [ ] Jun [ ] Jul
[ ] Aug
[ ] Sep [ ] Oct [X] Nov [X] Dec
Venting [ ] Jan
[] Feb
[X] Mar
[X] Apr
(] May [I Jun []Jul
[ ] Aug
[ ] Sep [X] Oct (X] Nov [ ] Dec
Thermostat Schedule: HERS 2006 Reference
Hours
Schedule Type
1
2
3 4 5 6
7
8 9 10
11 12
_Cooling(WD)
AM
78
78
78 78 78 78
78
78 78 78
78 78
PM
78
78
78 78 78 78
78
78 78 78
78 78
_Cooling(WEH)
AM
78
78
78 78 78 78
78
78 78 78
78 78
PM
78
78
78 78 78 78
78
78 78 78
78 78
Heating (WD)
AM
68
68
68 68 68 68
68
68 68 68
68 68
PM
68
68
68 68 68 68
68
68 68 68
68 68
_Heating(WEH)
AM
68
68
68 68 68 68
68
68 68 68
68 68
PM
68
68
68 68 68 68
68
68 68 68
68 68
6f7/2021 11:47:00 AM EnergyGauge® USA 7.0.00 - FlaRes2020 FBC 7th Edition (2020) Compliant Software Page 5
2020 - AIR BARRIER AND INSULATION INSPECTION COMPONENT CRITERIA
TABLE 402.4.1.1
AIR BARRIER AND INSULATION INSPECTION COMPONENT CRITERIAa
Project Name: WYNNE BUIDLING-THE COTTAGE IMPACT Builder Name: WYNNE BUILDING CORP.
Street: THE COTTAGE Permit Office: ST. LUCIE COUNTY
City, State, Zip: FT. PIERCE, FL, Permit Number:
Y
Owner: WYNNE BUILDING CORP. Jurisdiction: U
Design Location: FL, Fort Pierce County: St. Lucie(Florida Climate Zone 2) _
U
COMPONENT
AIR BARRIER CRITERIA
INSULATION INSTALLATION CRITERIA
General
A continuous air barrier shall be installed in the building envelope.
Air-permeableinsulationshall
requirements
The exterior thermal envelope contains a continuous air barrier.
not be used as a sealing material.
Breaks orjoints in the air barrier shall be sealed.
The air barrier in any dropped ceiling/soffit shall be aligned with
The insulation in any dropped ceiling/soffit
Ceiling/attic
the insulation and any gaps in the air barrier shall be sealed.
shall be aligned with the air barrier.
Access openings, drop down stairs or knee wall doors to
unconditioned attic spaces shall be sealed.
Walls
The junction of the foundation and sill plate shall be sealed.
Cavities within comers and headers of frame walls
The junction of the top plate and the top of exterior walls shall be
shall be insulated by completely filling the cavity with
sealed.
a material having a thermal resistance of R-3 per
Knee walls shall be sealed.
inch minimum
Exteriorthermal envelope insulation for framed walls
shall be installed in substantial contact and
continuous alignment with the air barrier.
Windows, skylights
The space between window/doorjambs and framing, and
anddoors
skylights and framing shall be sealed.
Rim joists
Rim joists shall include the air barrier.
Rim joists shall be insulated.
Floors
The air barrier shall be installed at any exposed edge of
Floor framing cavity insulation shall be installed to
(including
insulation.
maintain permanent contact with the underside of
above -garage
subfloor decking, or floor framing cavity insulation
and cantilevered
shall be permitted to be in contact with the top side
floors)
of sheathing, orcontinuous insulation installed on
the underside of floor framing and extends from the
bottom to the top of all perimeter floor framing
members.
Crawl space walls
Exposed earth in unvented crawl spaces shall be covered
Where provided instead of floor insulation, insulation
with a Class l vapor retarder with overlapping joints taped.
shall be permanently attached to the crawlspace walls.
Shafts, penetrations
Dud shafts, utility penetrations, and flue shafts opening to
exterior or unconditioned space shall be sealed.
Narrow cavities
Batts in narrow cavities shal I be cut to fit, or narrow
cavities shall be filled by insulation that on
installation readily conforms to the available cavity
spaces.
Gawgeseparation
Air sealing shall be provided between the garage and
conditionedspaces.
Recessedlighting
Recessed lightfixtures installed in the building thermal
Recessed lightfixtures installed in the building
envelope shall be sealed to the finished surface.
thermal envelope shall be air tight and IC rated.
Plumbing and wiring
Batt insulation shall be cot neatly to fit around wiring
and plumbing in exterior walls, or insulation that on
installation readily conforms to available space shal I
extend behind piping and wiring.
Shower/tub
The air barrier installed at exterior walls adjacent to showers
Exterior walls adjacent to showers and tubs shall
on exteriorwall
and tubs shall separate them from the showers and tubs.
beinsulated.
Electrical/phonebox
The air barrier shall be installed behind electrical or
on exteriorwalls
communication boxes orair-sealed boxes shall be installed.
HVAC register boot
HVAC supply and return register boots that penetrate building
thermal envelope shall be sealed to the sub -floor, wall covering
or ceiling penetrated by the boot.
Concealed
When required to be sealed, concealed fire sprinklers shall only
sprinklers
be sealed in a manner that is recommended by the manufacturer.
Caulking or other adhesive sealants shall not be used to fill voids
voids between fire sprinkler cover plates and walls or ceilings.
a. In addition, inspection of log walls shall be in accordance with the provisions of ICC-400.
6/7/2021 11:47:00 AM EnergyGauge® USA 7.0 - FlaRes2020 FBC 7th Edition (2020) Compliant Software Page 1
FORM R405-2020
ENERGY PERFORMANCE LEVEL (EPL) DISPLAY CARD
ESTIMATED ENERGY PERFORMANCE INDEX* = 96
The lower the EnergyPerformance Index, the more efficient the home.
THE COTTAGE,FT. PIERCE,FL,
1. New construction or existing New (From Plans)
2. Single family or multiple family
Detached
3. Number of units, if multiple family
1
4. Number of Bedrooms
1
5. Is this a worst case?
Yes
6. Conditioned floor area above grade (ft2)
1306
Conditioned floor area below grade (ft2)
0
7. Windows- Description
Area
a. U-Factor: Sgl, U=1.02
76.04 ft2
SHGC: SHGC=0.29
b. U-Factor: Sgl, U=1.03
40.00 ft2
SHGC: SHGC=0.27
c. U-Factor: Sgl, U=1.02
12.85 ftZ
SHGC: SHGC=0.26
Area Weighted Average Overhang Depth:
4.701 ft
Area Weighted Average SHGC:
0.281
8. Skylights Description
Area
U-Factor:(AVG) N/A
N/A ft2
SHGC(AVG): N/A
9. Floor Types Insulation
Area
a. Slab -On -Grade Edge Insulation R= 0.0
1306.00 ft2
b. N/A R=
ft2
c. N/A R=
ft2
10.
Wall Types(1718.3 sqft.)
Insulation
Area
a. Concrete Block - Int Insul, ExteriorR=4.1
1478.30 ft2
b. Frame - Wood, Adjacent
R=11.0
240.00 ft2
c. N/A
R=
ft2
d. N/A
R=
ft2
11.
Ceiling Types(1336.0 sqft.)
Insulation
Area
a. Under Attic (Vented)
R=30.0
1306.00 ft2
b. Knee Wall (Vented)
R=19.0
30.00 ft2
c. N/A
R=
ft2
12.
Ducts, location & insulation level
R ft2
a. a. Sup: Attic, Ret: Attic, AH: Attic
6 120
b.
C.
13.
Cooling Systems
kBtu/hr
Efficiency
a. Central Unit
29.0 SEER:14.00
14.
Heating Systems
kBtu/hr
Efficiency
a. Electric Heat Pump
27.0
HSPF:8.20
15. Hot Water Systems
a. ElectricTankless Cap: 1 gallons
EF: 0.600
b. Conservation features
None
16. Credits None
I certify that this home has complied with the Florida Energy Efficiency Code for Building
Construction through the above energy saving features which will be installed (or exceeded)
in this home before final inspection. Otherwise, a new EPL Display Card will be completed
based on installed Code compliant features.
Builder Signature: Date: �9 `� \
Address of New Home: THE COTTAGE City/FL Zip: FT. PIERCE,FL,
*Note: This is not a Building Energy Rating. If your Index is below 70, your home may qualify for
energy efficient mortgage (EEM) incentives if you obtain a Florida Energy Rating. For information about the
Florida Building Code, Energy Conservation, contact the Florida Building Commission's support staff.
**Label required by Section R303.1.3 of the Florida Building Code, Energy Conservation, if not DEFAULT.
677/2021 11:47:00 AM EnergyGauge@ USA 7.0.00 - FlaRes2020 FBC 7th Edition (2020) Compliant Software Page 1 of 1