Loading...
HomeMy WebLinkAboutattachment 1Date..• � � i 6 � L"A." IL Contractor: lob Address. Construction: Planning & Development Services Building & Cade Regulatloon Division 2300 Virginia Ave-, Rm 201 Fort Pierce, FL 34982 Phone: 772-462-2165 Fax: 772-462-6443 BLOWER DOOR TEST FORM House Infiltration Test Certification Prescriptive and Performance Method Cal Permit M. 9 Z i7 S t'I P..de✓ Cco.a� �d � L T /�o.ta ^�-L ? �7 �' New Construction —Complete ( )Existing — After Addition House Infiltration Test Results CFM (50) `i � Volume �1 ACH (50) = CFM (50) x 60 / Volume = � `� Passing results must be & ACH (50) or less PLC Climate Zone 2 Test Date: 2,0,1 Mechanical Ventilation required less than (V) Pass ( ) Fail 3 ACH F13C, energy The building or dwelling unit shall be tested and verified as having an air leakage rate of not exceeding 7 air changes per hour in Climate Zone 1, 2 and 3 air changes per hour in Climate Zones 3 through 8. Testing shall be conducted with a blower door at a pressure of 0.2 inches w. g. (50 Pascals). Testing shall be conducted by either 1-ndividual5 as defined in Section 553.993(5) or (7), Florida Statutes or individuals licensed as set forth in Section 489.105 (3)(f), (g) or (i) or an approved third party. A written report of the results of the test shall be signed by the party conducting the test and provided to the code official. Testing shall be per -formed at any time after creation of all penetrations of the building thermal envelope. f:BC, Residential Where the air infiltration rate of a dwelling unit is fens than 3 air changes per hour when tested with a blower door at a pressure of 0.2 inch w. c. (50 Pa) in accordance with Section R402.4.1.2 of the Florida Buildl*ng Cade, Energy Conservotl'on the dwelling unit shall be provided with whale -house mechanical ventilation an accordance with section M1507.3. Testing Company Company Name.. Pro -Duct Services Address-. 1915 Rio Vista Drive, Ft. Pierce, FL 34949 hereby certify that the above House Infiltration results demonstrate compliance with FBC Energy Conservation requirements in accordance with Section R402.4.1.2 Climate done 2. Im Signature: Printed Name: Martin Klein License/Certi�icativn #.E 5061633 4 Planning & Development Services Building & Code Regulation Division 2300 Virginia Ave, Rm 201 Fort Pierce, FL 34982 772-462-2165 Fax 772-462-6443 FBC ENERGY CONSERVATION CODE Duct Sealing Cerbificatlan rrescrlptive and Performance Method oats:: � � � b � L �' �[ Pemnit 6 7 dot #: Contractor: � `� .a Address. ram' •:����e�r��f -�.j ���� � �' 1 C-onstructon: Post Construction Test o Rough -in Test Test Conditions: Dam' � �'� t Floor Area (ft2)- Time: Primary Location of Supply Ductwork t �. indoor Temperature (F): Primary Location of Return Ductwork Outdoor Temperature (F): IM-4aka-g-o Test (Outside� Duct Leakage: o Default �. Leak Free o Proposed On _ � • '' 3 Test Pressure: "z-- - - (Pa) Baseline Duct Pressure (optional) —(Pa) duct Press. (Pa) Flow Ring Fan Press Flow (ch) Resufts:Iss o Fail Installed (Pa 0 Taal Leakage (cfm)4. Total Leakage per 100 sqft: rWL - 3° � � .� � • �' �- CFM25 x 100 divided by the CFA Duct Leakage CFM/1 00 sqft. Testns Comony Company Name: Pry -Dust Services Address: I hereby cetfy that the above Duct Sealing Leakage results demonstrate compliance wfth 5�1 Edifion FBC Energy Conservabon requirements in accordance with Section R403.2.21. Signature: Printed Name: Marfin Klein License/Cerfificate #: 50616331, �37 } lb 41 I 10 _.BUILDING PERFORMANCE INSTITUTE, INC 107 Hermes Road. Suite 210 Malta, NY 12020 (877) 274-1274 w��v.bpi.org ode-. Martin Klein 11 BPI ID '. 5061633 (-ShE RE ER CE SIDE FOR DESIGNATIONS ANO EXPIRATION DATES) CERTIFIED PROFESS*NAL MI N TION EXPIRATION DATE InffitraUon & Dui! Leakagc 412612024 BUILDING PERFORMANCE INSTITUTE, INC