HomeMy WebLinkAboutAPPROVED, FL10884 SOLAR STAR-mergedINSTALLATION NOTES:
1.ONE (1) INSTALLATION ANCHOR IS REQUIRED AT EACH ANCHOR LOCATION SHOWN ON SHEETS 2 AND 3.
2.THE NUMBER OF INSTALLATION ANCHORS DEPICTED IS THE MINIMUM NUMBER OF ANCHORS TO BE
USED FOR PRODUCT INSTALLATION. ALL UNITS REQUIRE EIGHT (8) ANCHORS MINIMUM LOCATED AT ALL
CORNERS.
2.1.SEE VENT TOP VIEW ON SHEETS 2 AND 3.
2.2.FOR PLYWOOD SUBSTRATES NOT MEETING THE MATERIAL REQUIREMENTS OF NOTE 6.1 BELOW,AN
ADDITIONAL EIGHT (8) ANCHORS ARE REQUIRED. THEY SHALL BE SPACED MIDSPAN BETWEEN THE
EIGHT (8) CORNER ANCHORS REQUIRED FOR ALL INSTALLATIONS AND SHOWN ON SHEETS 2 AND 3.
3.FOR INSTALLATION INTO PLYWOOD/OSB ROOFING, USE NO. 10, TYPE AB, PAN HEAD, ROUND HEAD OR
TRUSS HEAD CORROSION RESISTANT STEEL TAPPING SCREWS MEETING ASME/ANSI B18.6.4 OF
SUFFICIENT LENGTH TO ACHIEVE FULL DEPTH OF EMBEDMENT INTO PLYWOOD/OSB SHEATHING A
MINIMUM OF 7/16" INCH IN THICKNESS. EDGE DISTANCE FROM CENTERLINE OF SCREW TO EDGE OF
PLYWOOD/OSB SHALL BE AT LEAST 1-1/4 INCH.
4.MINIMUM EMBEDMENT AND EDGE DISTANCE EXCLUDE ROOF FINISHES.
5.INSTALLATION ANCHORS MUST BE MADE OF CORROSION RESISTANT MATERIAL OR HAVE A CORROSION
RESISTANT COATING.
6. INSTALLATION ANCHOR CAPACITIES FOR PRODUCTS HEREIN ARE BASED ON SUBSTRATE MATERIALS
WITH THE FOLLOWING PROPERTIES:
6.1.7/16" THICK PLYWOOD - SPECIES GROUP 1 OR 2 (APA VOLUNTARY PRODUCT STANDARD PS 1)
MINIMUM.
6.1.1.FOR PLYWOOD SPECIES NOT MEETING SPECIES GROUP 1 OR 2, SEE NOTE 2.2 ABOVE FOR
ADDITIONAL ANCHORAGE REQUIRMENTS.
6.2.7/16" OSB - SHEATHING GRADE (APA VOLUNTARY PRODUCT STANDARD PS 2) MINIMUM.
GENERAL AND INSTALLATION NOTES
2
3
1
SHEET SHEET DESCRIPTION
TABLE OF CONTENTS
LOW PROFILE ELEVATION, ANCHORING & SECTIONS
REV.
B
B
B
GENERAL NOTES:
1.THE PRODUCT ANCHORAGE SHOWN HEREIN IS DESIGNED TO COMPLY WITH THE CURRENT EDITION
OF THE FLORIDA BUILDING CODE (FBC) INCLUDING ITS SUPPLEMENTS AND EXCLUDING THE HIGH
VELOCITY HURRICANE ZONE (HVHZ) AT THE DESIGN PRESSURES STATED HEREIN.
2.THE PRODUCT DETAILS CONTAINED HEREIN ARE BASED UPON SIGNED AND SEALED TEST REPORT
95385.01-301-44 AND ASSOCIATED LABORATORY STAMPED DRAWINGS.
3.THE PRODUCT HAS BEEN STRUCTURALLY TESTED AND FOUND TO BE IN CONFORMANCE TO THE
CURRENT EDITION OF THE FLORIDA BUILDING CODE (FBC). THE DESIGN PRESSURES SHOWN IN
DESIGN PRESSURE RATING TABLE ON SHEET 1 OF THIS DRAWING ARE BASED ON THE RESULTS OF
TEST REPORT NO. 95385.01-301-44 TESTING TO ASTM E330-02 DIVIDED BY A FACTOR OF SAFETY OF 2.
4.PLASTIC COMPONENTS OF THE SOLATUBE SOLAR STAR ROOF VENT HAVE BEEN EVALAUTED TO THE
REQUIREMENTS OF THE CURRENT EDITION OF THE FLORIDA BUILDING CODE AND ARE IN
COMPLIANCE AS DOCUMENTED IN PRODUCT EVALUATION REPORT NO. 1904 BY ROBERT J. AMORUSO,
P.E.
5.ADEQUACY OF THE EXISTING STRUCTURAL ROOF SHEATHING AND SUPPORTING 2X FRAMING AS A
MAIN WIND FORCE RESISTING SYSTEM CAPABLE OF WITHSTANDING AND TRANSFERRING APPLIED
PRODUCT LOADS TO THE FOUNDATION IS THE RESPONSIBILITY OF THE ENGINEER OR ARCHITECT OF
RECORD FOR THE PROJECT OF INSTALLATION.
6.THE INSTALLATION DETAILS DESCRIBED HEREIN ARE GENERIC AND MAY NOT REFLECT ACTUAL
CONDITIONS FOR A SPECIFIC SITE. IF SITE CONDITIONS CAUSE INSTALLATION TO DEVIATE FROM THE
REQUIREMENTS DETAILED HEREIN, A LICENSED ENGINEER OR ARCHITECT SHALL PREPARE SITE
SPECIFIC DOCUMENTS FOR USE WITH THIS DOCUMENT.
7.THE SOLAR STAR'S PRIMARY COMPONENTS ARE COMPRISED OF THE FOLLOWING MATERIALS:
7.1.FLASHING AND TOP PANEL: ALUMINZED STEEL EDDS T1-25 (TYPE 1)
7.2.STANDOFF, 10 x 1 x 74: ALUMINUM 6061-T6
7.3.FAN GRILL: POLYPROPYLENE
8.THIS PRODUCT EVALUATION DOCUMENT ADDRESSES THE STRUCTURAL ATTACHMENT OF THE ROOF
VENT TO THE ROOF SHEATHING ONLY. PREPARATION OF THE ROOF SHEATHING AND ROOF COVERING(S)
TO RECEIVE THE ROOF VENT SHALL BE PER THE MANUFACTURER'S INSTRUCTIONS.
9.INTERNAL MECHANISMS, ELECTRICAL COMPONENTS AND SOLAR COMPONENTS ARE BEYOND THE SCOPE
OF THIS PRODUCT EVALUATION DOCUMENT.PTC PRODUCT DESIGN GROUP, LLCPO BOX 520775LONGWOOD, FLORIDA 32752FBPE C.A. NO. 25935Phone: 321.690.1788Fax: 321.690.1789Email: info@ptc-corp.comTITLE:DRAWN BY:SCALE:REV:DATE:DRAWING NO:SHEET:PREPARED BY:PROJECT NUMBER:BYDATEDESCRIPTIONREVRobert J. Amoruso, P.E.
FL P.E. No. 49752
SOLATUBE
SOLAR STAR LOW & HIGH PROFILE ROOF VENTS
INSTALLATION ANCHORAGE DETAILS
HIGH PROFILE ELEVATION, ANCHORING & SECTIONS
SOLAR STAR
LOW PROFILE VENT
SECTION A
ROOF LINE
SOLAR STAR RM-1500
LOW PROFILE VENT
TOP VIEW
INSTALLATION ANCHORS
(SEE INSTALLATION
NOTES SHEET 1)
25.30"
A A
2.50"
3.88"
23.60"
25.30"
SECTION A-A
10.50"
A
7/16" MIN.
EMBEDMENT
6.38"
INSTALLATION ANCHORS AT
CORNERS, 8X REQUIRED25.30"
10.50"
A A
SOLAR STAR RM-2400
LOW PROFILE VENT
TOP VIEW
25.30"PTC PRODUCT DESIGN GROUP, LLCPO BOX 520775LONGWOOD, FLORIDA 32752FBPE C.A. NO. 25935Phone: 321.690.1788Fax: 321.690.1789Email: info@ptc-corp.comTITLE:DRAWN BY:SCALE:REV:DATE:DRAWING NO:SHEET:PREPARED BY:PROJECT NUMBER:BYDATEDESCRIPTIONREVRobert J. Amoruso, P.E.
FL P.E. No. 49752
SOLAR STAR
HIGH PROFILE VENT
B
ROOF LINE
SOLAR STAR RM-1500
HIGH PROFILE VENT
TOP VIEW
25.30"
B B
25.30"
10.50"
6.0"
3.88"
23.60"
9.88"
SECTION B-B
SECTION B
7/16" MIN.
EMBEDMENT
INSTALLATION ANCHORS
(SEE INSTALLATION
NOTES SHEET 1)
INSTALLATION ANCHORS AT
CORNERS, 8X REQUIRED25.30"
10.50"
B B
SOLAR STAR RM-2400
HIGH PROFILE VENT
TOP VIEW
25.30"PTC PRODUCT DESIGN GROUP, LLCPO BOX 520775LONGWOOD, FLORIDA 32752FBPE C.A. NO. 25935Phone: 321.690.1788Fax: 321.690.1789Email: info@ptc-corp.comTITLE:DRAWN BY:SCALE:REV:DATE:DRAWING NO:SHEET:PREPARED BY:PROJECT NUMBER:BYDATEDESCRIPTIONREVRobert J. Amoruso, P.E.
FL P.E. No. 49752