HomeMy WebLinkAboutNOA Ridge Vent Owens corning
NOA No.: 21-0209.03
Expiration Date: 04/07/2022
Approval Date: 04/02/2021
Page 1 of 7
MIAMI-DADE COUNTY
PRODUCT CONTROL SECTION
DEPARTMENT OF REGULATORY AND ECONOMIC RESOURCES (RER) 11805 SW 26 Street, Room 208
BOARD AND CODE ADMINISTRATION DIVISION Miami, Florida 33175-2474
T (786) 315-2590 F (786) 315-2599
NOTICE OF ACCEPTANCE (NOA) www.miamidade.gov/economy
Owens Corning Roofing and Asphalt, LLC
One Owens Corning Parkway
Toledo, OH 43659
SCOPE:
This NOA is being issued under the applicable rules and regulations governing the use of construction materials. The
documentation submitted has been reviewed and accepted by Miami-Dade County RER - Product Control Section to be
used in Miami Dade County and other areas where allowed by the Authority Having Jurisdiction (AHJ).
This NOA shall not be valid after the expiration date stated below. The Miami-Dade County Product Control Section
(In Miami Dade County) and/or the AHJ (in areas other than Miami Dade County) reserve the right to have this product
or material tested for quality assurance purposes. If this product or material fails to perform in the accepted manner, the
manufacturer will incur the expense of such testing and the AHJ may immediately revoke, modify, or suspend the use
of such product or material within their jurisdiction. RER reserves the right to revoke this acceptance, if it is
determined by Miami-Dade County Product Control Section that this product or material fails to meet the requirements
of the applicable building code.
This product is approved as described herein, and has been designed to comply with the Florida Building Code
including the High Velocity Hurricane Zone of the Florida Building Code.
DESCRIPTION: VentSure® 4-Foot Strip Heat and Moisture Ridge Vents, VentSure® 4-Foot Strip Heat and
Moisture Ridge Vents with Weather PROtector® Moisture Barrier, VentSure® Sky Runner
LTE® Roll Vent.
LABELING: Each unit shall bear a permanent label with the manufacturer's name or logo, city, state and following
statement: "Miami-Dade County Product Control Approved", unless otherwise noted herein.
RENEWAL of this NOA shall be considered after a renewal application has been filed and there has been no change
in the applicable building code negatively affecting the performance of this product.
TERMINATION of this NOA will occur after the expiration date or if there has been a revision or change in the
materials, use, and/or manufacture of the product or process. Misuse of this NOA as an endorsement of any product, for
sales, advertising or any other purposes shall automatically terminate this NOA. Failure to comply with any section of
this NOA shall be cause for termination and removal of NOA.
ADVERTISEMENT: The NOA number preceded by the words Miami-Dade County, Florida, and followed by the
expiration date may be displayed in advertising literature. If any portion of the NOA is displayed, then it shall be done
in its entirety.
INSPECTION: A copy of this entire NOA shall be provided to the user by the manufacturer or its distributors and
shall be available for inspection at the job site at the request of the Building Official.
This NOA renews NOA No.20-0221.03 and consists of pages 1 through 7.
The submitted documentation was reviewed by Freddy Semino
NOA No.: 21-0209.03
Expiration Date: 04/07/2022
Approval Date: 04/02/2021
Page 2 of 7
ROOFING ASSEMBLY APPROVAL
Category: Roofing
Sub-Category: Ventilation
Materials: Plastic
TRADE NAMES OF PRODUCTS MANUFACTURED OR LABELED BY APPLICANT
Product
Dimensions
Test
Specification
Product
Description
VentSure® 4-Foot Strip
Heat and Moisture Ridge
Vents
Manufacturing Location
#1
Width = 14.875”
Length = 48”
Height = 1.25”
TAS 100(A) Plastic low profile attic ridge vent. For
installation in asphalt shingle roof systems.
VentSure® 4-Foot Strip
Heat and Moisture Ridge
Vents
Manufacturing Location
#2
Width = 14.375”
Length = 48”
Height = 1”
TAS 100(A) Plastic low profile attic ridge vent. For
installation in asphalt shingle roof systems.
VentSure® 4-Foot Strip
Heat and Moisture Ridge
Vents (with Weather
PROtector® Moisture
Barrier)
Manufacturing Location #1
Width = 14.375”
Length = 48”
Height = 1.25”
TAS 100(A) Plastic low profile attic ridge vent with a
polyester fabric moisture barrier. For
installation in asphalt shingle roof systems.
VenSure® Sky Runner
LTE® Roll Vent
Manufacturing Location #1
Width = 14.5”
Length = 30’
Height = 5/8 “
TAS 100 (A)
Plastic low profile attic shingle over ridge vent.
For installation in asphalt shingle roof systems.
VentSure Nail
Manufacturing Location #3
Length = 2.5”
Diameter = 0.125”
Head Diameter: 0.325”
TAS 114
Appendix E
Corrosion resistant nails for use with
VentSure Ridge Vents.
MANUFACTURING LOCATIONS
1. ML#1
2. ML#2
3. ML#3
NOA No.: 21-0209.03
Expiration Date: 04/07/2022
Approval Date: 04/02/2021
Page 3 of 7
EVIDENCE SUBMITTED
Test Agency/Identifier Name Report Date
PRI Construction Materials OCF-116-02-01 TAS 100(A) 05/12/09
Technologies OCF-112-02-01 ASTM G 155
ASTM D 638
05/11/09
OCF-132-02-01 TAS 114 Appendix E 10/05/09
OCF-223-02-01 TAS 100 (A) 06/06/14
OCF-159-02-01
OCF-160-02-01
OFC-161-02-01
ASTM D 1929
ASTM D635
ASTM D 2843
11/09/2010
11/09/2010
11/09/2010
OCF-155-02-01 TAS 110-2000 10/08/2010 - 05/01/2011
OCF-268-02-03 TAS 100(A) 01/07/2016
ETC Laboratories
ETC-08-718-21721.1 ASTM D 1929
ASTM D635
ASTM D 2843
12/08/08
APPROVED APPLICATIONS
Trade Name: VentSure® 4-Foot Strip Heat and Moisture RidgeVent (with or without Weather
PROtector® Moisture Barrier)
System Type A: Mechanical attachment of ridge vent system for asphalt shingle roofs
Slot: Cut a 2” opening (1” on each side of the ridge) centered in the deck at the ridge for
ventilation. The slot shall terminate approximately 6” from the rake edges.
Installation: Apply a ¼” bead of approved roofing cement along the entire length of the outside edges
of the vent to seal the vent to the field shingles.
Center the vent over the opening and fasten to the deck using the Ventsure Nails or
corrosion resistant 11 ga. 2 ½” galvanized ring shank nails. Fasteners are placed on both
sides of the vent at 1”, 12”, 24”, 36”, and 47” from the start of each vent piece. Nails shall
be of sufficient length to penetrate through the sheathing a minimum of 3/16”.
Prepare the adjacent vent section by applying the roofing cement along the edges, snap
together with fixed vent, and fasten to the deck in the same manner as the first section.
Fasten the ridge shingles over the vent to the deck on the marked “shingle nail line” with
(2) Ventsure nails per shingle or in accordance with the shingle manufacturer’s approved
Notice of Acceptance. Outside edges of the shingles are to be sealed with and approved
flashing cement.
Ventilation Calculations: Refer to manufacturer’s published literature for net free area.
Minimum Slope: 2:12
NOA No.: 21-0209.03
Expiration Date: 04/07/2022
Approval Date: 04/02/2021
Page 4 of 7
Trade Name: VentSure® Sky Runner LTE® Roll Vent
System Type B: Mechanical attachment of ridge vent system for asphalt shingle roofs
Slot: Cut a 1 1/4” wide cut-slot at ridge. Opening (5/8 ”on each side of the ridge) centered in
the deck at the ridge for ventilation. The slot shall terminate approximately 6” from the
rake edges.
Installation: Apply a ¼” bead of approved roofing cement along the entire length of the outside edges
of the vent to seal the vent to the field shingles.
Center the vent over the opening and fasten to the deck using the corrosion resistant 12 ga.
2” galvanized ring shank nails .Fasteners are placed on both sides of the vent at molded
location (4 per linear ft.) Remove any slack from the vent and nail the vent every 6 in.
nailing from one side of the vent than the other. Nails shall be of sufficient length to
penetrate through the sheathing a minimum of 3/16”.
Prepare the adjacent vent section by applying the roofing cement along the edges, snap
together with fixed vent, and fasten to the deck in the same manner as the first section.
Fasten the ridge cap shingles over the vent to the deck on the marked “shingle nail line”
with (2) nails per shingle or in accordance with the shingle manufacturer’s approved
Notice of Acceptance. Outside edges of the shingles are to be sealed with and approved
flashing cement. End plugs are built into the vent every 12 in. The vent should always
begin and end with an end plug. Refer to manufactures installation manual.
Ventilation Calculations: Refer to manufacturer’s published literature for net free area.
Minimum Slope: 2:12
NOA No.: 21-0209.03
Expiration Date: 04/07/2022
Approval Date: 04/02/2021
Page 5 of 7
GENERAL LIMITATIONS:
1. Refer to applicable building code for required ventilation.
2. The installation shall be applied in compliance with the manufacturer's current published application instruction
and the requirements set forth in applicable building code.
3. VentSure® 4-Foot Strip Heat and Moisture RidgeVent (with or without Weather PROtector® Moisture Barrier)and
Sky Runner LTE® Roll Vent is approved to be installed over asphalt shingles only .
4. VentSure® 4-Foot Strip Heat and Moisture RidgeVent (with or without Weather PROtector® Moisture Barrier) and
Sky Runner LTE® Roll Vent shall not be installed on roof mean heights greater than 75 ft.
5. All products listed herein shall have a quality assurance audit in accordance with the Florida Building Code and
Rule 61G20-3 of the Florida Administrative Code.
6. All plastic ridge vents manufacturers shall have an unannoucned follow-up quality control program from an
approved listing agency. Follow-up test results shall be made available to Miami-Dade Product Control Office
upon request.
7. All approved products listed herein shall be labeled and shall bear the imprint or identifiable marking of the
manufacturer's name or logo, city and state of manufacturing facility, and following statement: "Miami-Dade
County Product Control Approved" or the Miami-Dade County Product Control Seal as shown below.
NOA No.: 21-0209.03
Expiration Date: 04/07/2022
Approval Date: 04/02/2021
Page 6 of 7
PROFILE DRAWINGS
48"
14.875"14.375” or 14.875”
NOA No.: 21-0209.03
Expiration Date: 04/07/2022
Approval Date: 04/02/2021
Page 7 of 7
END OF THIS ACCEPTANCE