APPROVED Design Pressure Report (Miletich) - Master Craft Aluminum Products
Property Information Owner:Miletich Address:9 El Camino Real Port St Lucie, Fl 34952 Building Information Wind Zone:160 MPH. Exposure Category:B Minimum Building Dimension:24 ft. Mean Roof Height:15 ft. Risk Category:II Design Pressure Calculations Opening Number Location Zone Device Width (in) Device Height (in) Device Elevation (ft) Max Positive Pressure (psf) Max Negative Pressure (psf) 1 Int 53 55 7 31.0 -33.7 2 Int 26 38 7 32.5 -35.2 3 Int 26 38 7 32.5 -35.2 4 Int 74 55 7 30.3 -33.0 5 Int 113 84 7 28.5 -31.3 6 Int 102 84 7 28.7 -31.5 7 Int 108 84 7 28.6 -31.3 8 Int 53 55 7 31.0 -33.7 9 Int 53 55 7 31.0 -33.7 Prepared in accordance with: ASCE 7-16, Chapter 30. Wind Loads - Components and Cladding. 7th Edition (2020) Florida Building Code. Page 1 of 1