HomeMy WebLinkAboutAPPROVED FL16342-R2Business & Professional Regulation
BCIS Home ; Log In s User Registration t Hot Topics Submit Surcharge Stats & Facts Publications Contact Us ` BCIS Site Map Links Search
db r 4 Product Approval
USER: Public User
Protg_rt Approval Menu > Prgdut P„-APy>IM,Iion Search > Aoolication List > Application Detail
FL # FL16342-R2
Application Type Revision
Code Version 2017
Application Status Approved
Comments
Archived
Product Manufacturer Drexel Metals, Inc.
Address/Phone/Email 204 Railroad Drive
Ivyland, PA 18974
(502) 303-1511
jshumate@drexmet.com
Authorized Signature Jason Shumate
jshumate@drexmet.com
Technical Representative
Address/Phone/Email
Quality Assurance Representative
Address/Phone/Email
Category Roofing
Subcategory Underlayments
Compliance Method Evaluation Report from a Florida Registered Architect or a Licensed
Florida Professional Engineer
Evaluation Report - Hardcopy Received
Florida Engineer or Architect Name who developed Zachary R. Priest
the Evaluation Report
Florida License PE-74021
Quality Assurance Entity UL LLC
Quality Assurance Contract Expiration Date 12/31/2020
Validated By Locke Bowden P.E.
1: Validation Checklist - Hardcopy Received
Certificate of Independence FL16342 R2 COI DRX13004 2 2017 FBC Evaluation R port MetShield
FINAL.odf
Referenced Standard and Year (of Standard) Standard Year
ASTM D 1970 2015
Equivalence of Product Standards
Certified By
Sections from the Code
Product Approval Method Method 1 Option D
Date Submitted
09/15/2017
Date Validated
09/18/2017
Date Pending FBC Approval
09/20/2017
Date Approved
12/12/2017
Summary of Products
FL #
Model, Number or Name
Description
16342.1
MetShield
ASTM D 1970 self -adhering roofing underlayment
Limits of Use
Approved for use in HVHZ: No
Approved for use outside HVHZ: Yes
Impact Resistant: N/A
Design Pressure: N/A
Other: See evaluation report for limits of use
Installation Instructions
FL.16342 R2 II DRX13004,2 2017 FBC Evaluation Report
MetShield FINAL Ddf
Verified By: Zachary R. Priest 74021
Created by Independent Third Party: Yes
Evaluation Reports
EL16342 R2 AE DRX13004 2 2017 FBC Evaluation Report
MetShield FINAL odf
Created by Independent Third Party: Yes
Contact Us :: 2601 Blair Stone Road. Tallahassee FL 32399 Phone: 850-487-1824
The State of Florida is an AA/EEO employer. Copyright 2007-2013 State of Florida :: Privacy Statement :: Accessibility Statement :: Refund Statement
Under Florida law, email addresses are public records. If you do not want your e-mail address released in response to a public -records request, do not send electronic
mail to this entity. Instead, contact the office by phone or by traditional mail. If you have any questions, please contact 850.487.1395. -pursuant to Section
455.275(1), Florida Statutes, effective October 1, 2012, licensees licensed under Chapter 455, F.S. must provide the Department with an email address if they have
one. The emails provided may be used for official communication with the licensee. However email addresses are public record. If you do not wish to supply a
personal address, please provide the Department with an email address which can be made available to the public. To determine if you are a licensee under Chapter
455, F.S., please click here .
Product Approval Accepts:
® of trcY M�
Credit Card
CREEK
Certificate of Authorization No. 29824
17520 Edinburgh Drive
Tampa, FL 33647
TECHNICAL SERVICES, LLC (813) 480-3421
EVALUATION REPORT
FLORIDA BUILDING CODE, 6T" EDITION (2017)
Manufacturer:
DREXEL METALS, INC. Issued September 14, 2017
1234 Gardiner Lane
Louisville, KY 40213
(502) 716-7143
www.drexmet.com
Quality Assurance: UL LLC (QUA9625)
SCOPE
Category:
Roofing
Subcategory:
Underlayments
Code Sections:
1507.1.1, 1507.2.4
Properties:
Physical properties
REFERENCES
Entity
Report No. Standard Year
TrinitylERD (TST6049)
C41280.10.12 ASTM D 1970 2015a
ICC-ES (EVL2396)
ESR-2206 ASTM D 1970 2015a
PRODUCT DESCRIPTION
AND APPLICATION
MetShield
MetShield is a coated-polyolefin-composite
film surfaced, self -adhered ASTM D 1970
underlayment for use on steep slope roofs.
Deck Type:
Solid or closely fitted plywood sheathing for new or existing
construction. Plywood deck shall be installed in accordance
with FBC requirements. Roof decks shall have no more than
1/8" gap at abutting joints.
Min. slope:
In accordance with FBC requirements
Attachment method:
Underlayment shall be attached in accordance with the FBC
Table 1507.1.1 and manufacturer's installation instructions.
Min. application temperature:
40oF. Contact the manufacturer when installing at temperatures
below 40°F.
Allowable roof coverings:
Permitted to be used as prescribed in FBC Table 1507.1.1 with
mechanically fastened roof coverings.
DRX13004.2 FL16342-R2 Page 1 of 2
This evaluation report is provided for State of Florida product approval under Rule 61 G20-3. The manufacturer shall notify CREEK
Technical Services, LLC of any product changes or quality assurance changes throughout the duration for which this report is valid.
This evaluation report does not express nor imply warranty, installation, recommended use, or other product attributes that are not
specifically addressed herein.
CREEK DREXEL METALS, INC.
MetShield
TECHNICAL SERVICES, LLC
LIMITATIONS
1) This evaluation report is not use in the HVHZ.
2) Fire Classification is not within the scope of this evaluation.
3) Wind uplift resistance in not within scope of this evaluation.
4) Installation of the evaluated product shall comply with this report, the FBC, and the manufacturer's published
application instructions. Where discrepancies exist between these sources, the more restrictive and FBC
compliant installation detail shall prevail.
5) Deck substrates shall be clean, dry, and free from any irregularities and debris. All fasteners in the deck
shall be checked for protrusion and corrected prior to underlayment application.
6) MetShield may be used as described in other current FBC product approval documents.
7) MetShield shall not be used with adhered tile roof coverings nor installed over existing roof coverings.
8) MetShield shall be exposed on the roof deck for a maximum duration of 30 days.
9) All products listed in this report shall be manufactured under a quality assurance program in compliance with
Rule 61 G20-3.
COMPLIANCE STATEMENT
The products evaluated herein by Zachary R. Priest, P.E. have demonstrated compliance with the Florida Building
Code, 6th Edition (2017) as evidenced in the referenced documents submitted by the named manufacturer.
,•`�,,Q`6'\�P�G E N RjF.., 2017.09.14
No 74021
= 04'00'
STATE OF :•�/:
�0�..•� rL« Zachary R. Priest, P.E.
'�� �. •, < O R , p '• ���� Florida Registration No. 74021
AyOrganization No. ANE9641
fil
CERTIFICATION OF INDEPENDENCE
CREEK Technical Services, LLC does not have, nor will it acquire, a financial interest in any company manufacturing or distributing
products under this evaluation.
CREEK Technical Services, LLC is not owned, operated, or controlled by any company manufacturing or distributing products under
this evaluation.
Zachary R. Priest, P.E. does not have, nor will acquire, a financial interest in any company manufacturing or distributing products
under this evaluation.
Zachary R. Priest, P.E. does not have, nor will acquire, a financial interest in any other entity involved in the approval process of the
product.
END OF REPORT
DRX13004.2 FL16342-R2 Page 2 of 2
This evaluation report is provided for State of Florida product approval under Rule 61 G20-3. The manufacturer shall notify CREEK
Technical Services, LLC of any product changes or quality assurance changes throughout the duration for which this report is valid.
This evaluation report does not express nor imply warranty, installation, recommended use, or other product attributes that are not
specifically addressed herein.