HomeMy WebLinkAboutAPPROVED, Polyglass MTS TUMAX ver 2020Business
'Professional Regulation
aCIS Home = Log In . User Registration . Hot Topics Submit Surcharge Stats A Facts
dUpr
Product Approval
USER: Public User
Pr u P_Pros I nu a Froduct or pp n earth > gypllratipn List > Application Detail
FL #
FL5259-R31
Application Type
Revision
Code Version
2020
Application Status
Approved
Comments
Archived
.'W.
r
Publications Contact Us , SCIS Site Map Links Search
Product Manufacturer POLYGLASS USA
Address/Phone/Email 1111 W. Newport Center Drive
Deerfield Beach, FL 33442
(954) 233-1330 Ext242
ma [pert@poIygIass.com
Authorized Signature Maury Alpert
malpert@polyglass,com
Technical Representative TECH REP
Address/Phone/Email 1111 West Newport Center Drive
Deerfield Beach, FL 33442
(866) 802-8017
uspolyglasstechnical@palyglass, cam
Quality Assurance Representative QA REP
Address/Phone/Email 1111 West Newport Center Drive
Deerfield Beach, FL 33442
(888) 410-1375
uspoIygIasstechnicaI@p0lygless. co
Category Roofing
Subcategory Underlayments
Compliance Method Eva luatlon Rep art from a Florida Registered Architect or a Licensed Florida
Professional Engineer
Evaluation Report - Hardcopy Received
Florida Engineer or Architect Name who developed the Robert Nieminen
Evaluation Report
Florida License PE-59166
Quality Assurance Entity UL LLC
Quality Assurance Contract Expiration Date 10/21/2022
Validated By John W. Knezevich, PE
Validation Checklist - Hardcopy Received
Certificate of Independence FL5�� 20 01 CQI NIEMINEN p
ff
Referenced Standard and Year (of Standard) Standard Year
ASTM D1970 2015
ASTM D226 2009
ASTM D4798 Z011
ASTM D6163 2015
ASTM D6164 2011
ASTM D6222 2011
ASTM ❑6509 2015
FM 4424 2011
FRSAITRI, Eton Edition 2018
UL 1892 2015
Equivalence of Product Standards
Certified By
Sections from the Code
Product Approval Method Method 1 Option D
Date Submitted
10/22/2020
Date Validated
10/26/2020
Date Pending PI C Approval
11/01/2020
Data Approved
12/15/2020
Date Revised
12/21/2020
Summary of Products
FL #
Nodelr Number or
Name
Description
5259.1
Polyglass Roof
Undedayments
Roeflng underlayments
llmid of Use
Approved for use in HVHZ: No
Approved for use outside HVHZ: red
Impact Resistanto N/A
Design Pressure: +N/A/-622.5
Other: 1.) The design Pressure in this
application relates to one Particular
underlayment system for use in tile roof
systems. Refer to ER Section 5.8.3 for other
systems and associated maximum deslgn
Installation Instructions
F R i I[ 020 0 0 RNA R POLY ERL YM F
R33.pd[
Vetfled By: Robert Nieminen PE-59166
Created by Independent Third party: Yes
Evaluation Reports
H 5259 R31 AE 2020 09 30 RNAL Eg p0I UNpFgIAyME,T,
R3lual f
Created by Independent Third Party: Yes
Pressures. 2.) Refer to ER Section 5 for
other limps of use.
ER Nekt
camont ua :: 26Oi 91ar5 RnaE Te eaa=z-+ t _Ppone1 aW-e81-la,
The Stale M Handle is an luVEEe empbyer n .: m_sw n
,lade, hands owl Mail addresses are public rtCprts.It you We me want ywre-mail Balms reand in spame Na publk-nI request Ep net send mmmmm ,I to she ¢,lily, oneaE, wsR as name I Ilene er by hadulmal mall. If you hem any meners, please uI 850 a$7,1395.-PUT.nt b Seed., 9s5,]RMI
,men Sunburn, areamee October 1, 2011 'Ile—, bomead under chapter 95$ E5. Met pmvpe the wimrtment wbm an ¢mall allrta Is linen hove one. The email, provided many be used b at —Will at—Wilwith the lirna s. Nowmr email addresses are pubnc moN. If you do not wish to supply a personal address, game
arcade Me Department win an email address which am be made available to Me public'a detamine If Was are a immune under chapter 955, Is., please cien brG.
Pm.. PP-1 Amepfa:
rr9L®EE®
Credit Card
Safe
NEnno etc.
CenAcore o)Autaodzallon x32A5s
353 Christian Street, Unit #13
Oxford, CT 06478
(203)262-9245
ENGINEER EVALUATE TEST
CONSULT
Polyglass USA, Inc. Evaluation Report P12060.02.09-1127
1111 West Newport Center Drive FL5259-R31
Deerfield Beach, FL 33442 Date of Issuance: 02/24/2009
(954)233.1330 Revision 27: 09/30/2020
SCOPE:
This Evaluation Report is issued under Rule 61G20-3 and the applicable rules and regulations governing the use of
construction materials in the State of Florida. The documentation submitted has been reviewed by Robert Nieminen, P.E. for
use of the product under the Florida Building Code and Florida Building Code, Residential Volume. The products described
herein have been evaluated for compliance with the 7"' Edition (2020) Florida Building Code sections noted herein.
DESCRIPTION: Polyglass Roof Underlayments
LABELING: Labeling shall be in accordance with the requirements the Accredited Quality Assurance Agency noted herein and
FBC 1507.1.1.
CONTINUED COMPLIANCE: This Evaluation Report is valid until such time as the named product(s) changes, the referenced Quality
Assurance or production facility location(s) changes, or Code provisions that relate to the product(s) change. Acceptance of our
Evaluation Reports by the named client constitutes agreement to notify NEMO ETC, L1C of any changes to the product(s), the
Quality Assurance or the production facility location(s). NEMO ETC, LLC requires a complete review of its Evaluation Report relative
to updated Code requirements with each Code Cycle.
ADVERTISEMENT: The Florida Product Approval Number (FUI) preceded by the words "NEMOI etc. Evaluated" may be displayed in
advertising literature. If any portion of the Evaluation Report is displayed, then it shall be done in its entirety.
INSPECTION: Upon request, a copy of this entire Evaluation Report shall be provided to the user by the manufacturer or its
distributors and shall be available for inspection at thejob site at the request ofthe Building Official.
This Evaluation Report consists of pages 1 through 17.
Prepared by:
„ ,r -
Robert J.M. Nieminen, P.E.
Florida Registmtian No. 59166, Florida OC4ANE1983
'�xs'. ,"„',`£"efdalmiWsealappearlgwasauthalzedby Robert Nlemfm,P.E.on
09M20M.T ismesnofsery asaneleRmnlallyslgneddommem
CEM"CeTON OF INMPENDENCE:
1. NEMO ETC, LLC does not have, nor does it intend to acquire or will it acquire, a financial interest in any company manufacturing or distributing
products it evaluates.
2. NEMO ETC, LLC is not owned, operated or controlled by any company manufacturing or distributing products It evaluates.
3. Robert Nieminen, P.E. does not have nor will acquire, a financial interest in any company manufacturing or distributing products for which the
evaluation reports are being issued.
4. Robert Nieminen, P.E. does not have, nor will acquire, a financial interest in any other entity involved in the approval process of the product.
5. This is a building code evaluation. Neither NEMO ETC, LLC nor Robert Nieminen, P.E. are, in any way, the Designer of Record for any project on
which this Evaluation Report, or previous versions thereof, is/was used for pennitting or design guidance unless retained specifically for that
purpose.
02019 NEMO ETC, LLC
ROOFING COMPONENT EVALUATION: fkmojetc.
Product Category: Roofing
Sub -Category: Underlayment
Compliance Statement: Roof Underlayments, as produced by Polyglass USA, Inc., have demonstrated compliance with the
following sections of the 7Lh Edition )2020) Florida Building Code through testing in accordance with the following Standards.
Compliance is subject to the Installation Requirements and Limitations / Conditions of Use set forth herein.
aeGrlon
roe
StandardYear
1504.3.1
Wind resistance
FM 47474
4
201
1504.3.1
Wind resistance
UL 1697
20155
1507.1.1/R905.1.1
Material standard
ASTM 0226
2009
1507.1.1, 1507.2.4, 1507.2.9.2 /
Material standard
ASTM D1970
2015
R905.1.1, R905.2.8.2
1507.3.3/ R905.3.3
Material standard
FRSA/TRL Sj#h Edition
2018
1507.11.2/11905.11.2
Material standard
ASTM D6163
2015
1507.11.2/
R905.11.2
Material standard
ASTM D61M
2011
1507.11.2/
R905.11.2
Material standard
ASTM D6222
2011
1507.11.2/
R905.11.2
Material standard
ASTM D6509
2015
TAS 310
3, REFERENCES:
Accelerated Weathering ASTM M798
2011
loft
Euninau.n
Before
Date
k'
Eumira0an
ggypnce
Data
ERDiT5T6049)
Wind Uplift
11757.01
08/13Q003
ERD(TSTE049)
30/90 Physicals
PLYG-SC1190D.03.17
03/10/2017
ERDITST6049)
Wind Uplift
11776.06.02
01/16/2003
ERD (TST 6049)
TM 103
PLYG-SC12115.W.17
08/08/2017
ERDITST60491
Wind Uplift
P3740.01.07
01/04/2007
ERDnITa i5 i
TAS 103
PLYG-SC1303S08.17
10/31/2017
ERD RST 6049)
A MD070
P511O.M.07-1
04/11/3007
FM ITST 1867)
Wind Uplft
3004091
01/12/2000
ERD ITST 6049)
Wind Upim
P9260.03.06
03/22/201
ICC-E5(EVL am)
IRCCompllance
ESR-1697
M/0112019
ERD(M 6049)
Wind Upl"dt
1`30540.11U0 R1 11/30QW3
M-D (Cl 3592)
HVH2 Compliance
NOA 17-0614.22
07/0/2017
ERDOW6049)
Tensile Adhesion
P21030.11.09-1
11/30/2009
Mir (TST 2508)
ASTM DUN
1%2DH7A
N/0VMN
ERDITST6o491
Wind Uplift
P11030.11.09-2
31/30/2009
NEMO(f5T6p49)
ATM D1970
MPLYG-18410.4.03.18
03/29/2018
ERD ITST 61
ATM D4977
P11030.11.09-3
11/30/3009
NEMODST6o491
Wind Uplift
4L-PLYG-18-003A1.19
01/11/2019
ERD DST 6049)
ATM UB70
P33360.06.10
06/25/2010
NEMOITST6M9)
ASTM M163
45-PLYG-18-002.01.1&A
01/24/2019
ERD DST 6049)
TAS 103
I'M370.03.11
03/02/2011
NEMO (TST EM9)
ASTM D6222
4 PL(G-18L0205.19C
05/20/2019
ERD(TST6049)
Tensile Adhesion
P33370.04.11
04/26/2011
NEMO ITST F049)
ASTM D1970
y.PLYG-19-SUDL-WA
09/30/2019
ERo(Mii 91
ASTM D1970
P37300.SO3]
10/19/2011
NEMO ITSF 6049)
TAS 103
4S-PLYG-18-004.10.1"
10/08/2019
ERD ITST 60491
TAS 103
P40390o&22-1
08/06/2012
MEMO ITST 60491
TAS 103
45-0LYG-18-004.10.19-I
10/08/3019
ERD (T5T 6049)
Temile Adhesion
P40390.08.13-2
08/07/2012
NEMOITST6D49)
TAS 103
45VLYG-18O04.1¢14L
10/09/2019
ERD(rST 6049)
Tensie Adhesion
C41420.09.12-3
09/11/2012
NEMO (TST 6049)
TAS 103
4J-PLYG-I9-SWDL-01A
10/10/2019
ERD LUST 6049)
Wind Uplift
P39680.03.13
03/04/2013
NEMO(M W49)
TAS 103
45-PLYG-18-004.12.19-F
12/11W019
ERD (TST 60,19)
WIA D1970
P4S370.04.13
006/2013
NEMO ITST 6049)
TM 203
4)-PLYG-19-55UDL-02A
01/02/2020
Den M spas)
Wind Uplift
P1738A2.07-R2
MAN/2013
NEMO(A 6049)
ASTM D1970
4S-PLVG-18-004.C1.20.H
01/14/20M
ERDmiT6049)
wend Uplift
11757.04.01 I-R3 W/30/2013
NEMOrWacae
ASTM D1970
"LYG-1&004.01.201
01/14/2020
ERD (TST spas)
ASTM D61M
P37590.03.13-3A 05/06/2013
NEMOITST6pA9)
TAS 103
4 PLYG-18004.01.20.A
o1/16/2020
ERD UST 6049)
ASTM D65D9
P37590.03.13.1-RS
06/26/2U13
NEMO MT seas)
ASrM D6164
45-PLYG-18A04.01.20.11
01/16/2020
ERD MT 6049)
Wind Uplift
1`41630.08.13
08/06/2013
NEMO(TST6M9)
ATM D6222
4S-PLYG-18 002.12.19-Ci1
03/07/2MO
ERDMised9)
ASTM D4601
Pose10.09.13
M/04/2013
NEMO ITST E49)
TAS 103
PLYG-SCI5855.05.20.A
05/29/2020
ERD(TT6049)
Wind Uplift
P11751.05.03-R1
11/26/2013
NEMO(TST 6049)
TAS 103
41-PLYG-2055UDL-01
07/06/2020
ERD ITST 60491
Wind Uplift
PI1781.11.03-R1
11/26/2013
NEW)(T5T 5049)
ASTMD62R
44-PIYG-1455Mu-MA
07/23/2020
ERD(TST6oap)
30/90 physicals
P45270.05.24
05/12/2014
NEMO(Mliea9)
ASTM D4798/01623
4j-PLYG-I9-SSUDL-05.A
M/10/2020
ERD (TST E009)
Tensile adheuon
6020.09.1a-5
09/08/2014
NEMOITT60491
ASTM DI970
41-PLYG-2OSSUDL-05.A
09/30/2020
ERD(TST a049)
Tendleadhesion
6020.09.1 6
09/08/2014
NEMO ITST 6(49)
TAS 103
4J-PLYG-I0-SSUDL-05.0
09/30/2020
Dan(TST 6049)
Tenslleadhesion
P46520.10.14
10/03/2014
NEMO mn 6049)
TAS 103
4jrPLYG-20-SSUDL-11
09/W/2020
NEMO ETC, LLC.
Evaluated Report P12060.U2.09-R27
Cerelk. fAUhedUaUon p32455
7-EDITION 20201NON-
( ) XVN2 EVALUATION
FI5259-11t31
Polyglass Roof Undedayments
Revision 27: Defila 020
Page 2 of 17
tn�
Examlraeon
Rd 6
R&_
IBM
pamkwtfm
ERD (TST 6049)
ASTM p1970/WM
P43290.10.14
10/17/2014
PRI(T5T5878)
Tensile Adhesion
ERD RST(019)
TAR IM
PLYG-SC7550.M.15
03124/20M
PRI ITST 5878)
TAS to
ERD(M E049)
Teoffe adhemn
P4390.04.15
041W/2ads
PRI (TST 5979)
TAS 103
ERD ITST 6049)
TAS 103
PM360.10.14-R1
05/18/2015
PRI (TST 5878)
TAS 103
ERD(TST6W9)
Wind uplilt
PLYGSC8905.05.161
05/17/2016
PRI TST 5878)
ASTM D6222
ERD (TST 6019)
ASTM D3970
PLYG-SCUn30.06.161
05/27/2016
PRIM75878)
ASTM 1:6164
ERD (TST E049)
Tensileadhesion
PLYG-SC10130.W 163
06/27/2016
Powlass USA
P/LAMdavk
ERD MT sods)
TAS 103
PLYGSC30130.W.1F3
06/27/20H
PoNgla"USA
Materials ATRda4t
ERD RST 6049)
ASTM D"M/04798
PLYG-SC80110.07.16
07/16/2016
ut pull
Quality Control
ERD TIST 6049)
Wind Uplift
PLYGSC12025.10.16
10/12/2016
UL (QUA9625)
Quallry Control
ERD (TST 6049)
TAS 103
PLYG-Sc13040.12.16
12/27/2016
UL(QUM625)
quality Control
4. PRODUCT
4.1
4.2
4.3
4.4
4.5
4.6
4.7
4.8
4.9
55D:
4.11
4.12
4.13
4.14
ONEMOletc.
Reference pate
PRW1111 04/08/2002
PUSH-00 a 02-01 07/14/20G3
PUSH-0354)2-01 ]"/2006
PUSA-055-02-02 12/10/2007
PUS4461 02-02 01/28/2008
PUM-080-02-01 07/29/2009
Mule -Hide Cr.L' 03/01/2008
P,wAick Compound OB/18/2011
Service (FL) 1/13/201
Smite Contrmation (TX) 11/07/2019
Flarlda BCli Current
r
Product
Material Standard
Plant(s)
Desalption
Elastobase
ASTM D6163
FL
Fiberglass -reinforced, SBS modified bitumen base sheet
Elastobase P
ASTM D6164
FL
Polyester -reinforced, SBS modified bitumen base sheet
Elastofiex S6 G
ASTM D6164
FL, PA
Polyester -reinforced, SBS modified bitumen cap sheet
FRSA/TRI 09-18
Elastoflex S6 G FR
ASTM D6164
FL
Polyester -reinforced, SBS modified bitumen cap sheet
FRSA/TRI 09-18
HydraGuard Dual Pro
ASTM D1970
FL
Nominal 60-mil thick dual -layer rubberized asphalt
waterproofing membrane, fiberglass reinforced, with a
Polyester fabric surface
HydraGuard Tile Pro
ASTM D1970
FL
Nominal 60-mil thick dual -layer rubberized asphalt
FRSA/TRI 09-18
waterproofing membrane, fiberglass reinforced, with a
Polyester fabric surface
Mule -Hide SA-APP Cap Sheet
ASTM D6222
FL
Polyester -reinforced, APP modified bitumen cap sheet
FRSA/7RI 09-18
Mule -Hide SA-APP Cap Sheet
ASTM D6222
FL
Polyester -reinforced, APP modified bitumen cap sheet
(FR)
FRSA/TRI 0948
Polyfiex G
ASTM D6222
FL
Polyester -reinforced, APP modified bitumen cap sheet for
FRSA/TRI 09-18
use as an alternate to Heat Applied"Cap Sheet" in the
'Two Ply System" from FRSA/TRl Florida High Wind
Concrete and Cloy Roof Tile Installation Manual, Sixth
Edition beneath mechanically fastened or adhered tile
roof systems
Polyflex G FR
ASTM D6222
FL
Polyester -reinforced, APP modified bitumen cap sheet for
FRSAITRI09-18
use as an alternate to Heat Applied"Cap Sheet" in the
"Two Ply System" from FRSA/TRI Florida High Wind
Concrete and Clay Roof Tile Installation Manual, Sixth
Edition beneath mechanically fastened tile roof systems
Polyfiex SA P
ASTM D6222
FL, TX
Polyester -reinforced, APP modified bitumen cap sheet
FRSA/TR109-18
Polyflex SA P FR
ASTM D6222
FL, TX
Polyester -reinforced, APP modified bitumen cap sheet
FRSA/TRI 09-18
Polyglass Base
ASTM D6509
FL
Fiberglass -reinforced, APP modified bitumen base sheet
Polyglass G2 Base Sheet I
ASTM D4601
AL
Fiberglass -reinforced, asphaltic base sheet
NEMO ETC, U.C. Evaluation Report P12060.02A9-11a7
Cenl/Imteof,%MWationn32a55 7'EDITION f20201 FBC NON-HVHZ EVALUATION R.5259-831
Polyglad Boor Undedayments Revialon27:09/30/2a20
Page 3 of 17
M
4.15
1G 4.16
T 4.17
4.18
4.19
4.20
4.21
5.1
5.2
5.3
5.4
5.5
Old caan l ur'
r
Product
Material Standard
Plant(s)
Description
Polystick lR-Xe
ASTM D1970
FL, PA, TX
Nominal 60-mil thick rubberized asphalt -waterproofing
membrane, glass fiber reinforced, with an aggregate
surface
Polystick RATS Plus
ASTM D1970
F4 NV,
Nominal 60-mil thick rubberized asphalt waterproofing
FRSA/TRI 09-18
PA, TX
membrane, glass fiber reinforced, surfaced with
polyolefinic film surface
Polystick MU-X
ASTM D1970'
FL, NV, PA
Nominal 54-mil thick dual -layer rubberized asphalt
waterproofing membrane, fiberglass reinforced, with a
polypropylene film surface
Polystick TU Max
ASTM D1970
FL, PA, TX
Nominal 60-mil thick rubberized asphalt waterproofing
FRSA/TRI09-18
membrane with a 190 g/mL polyester fabric surface
Polystick TU P
FRWMI 09-18
FL, PA, TX
Nominal 130-mil thick rubberized asphaltwaterproofing
membrane, glass-fiber/polyester reinforced, with a
granular surface
Polystick TU Plus
ASTM D1970
FL, PA, TX
Nominal 80-mil thick rubberized asphalt waterproofing
FRSA/rRI 09-18
membrane, glass fiber reinforced, with a polyester fabric
surface
Polystick XFR
AS TM D1970
NV, TX
Nominal 80-mil thick rubberized asphalt waterproofing
FRSAITRI09-18
membrane, glass fiber reinforced, surfaced with
teMured film surface
This is a Building Code Evaluation. Neither NEMO ETC, LLC nor Robert Nlemmen, P.E. are, in anyway, the Designer of Record for
any project on which this Evaluation Report, or previous versions thereof, is/was used for permitting or design guidance unless
retained specifically for that purpose.
This Evaluation Report is not for use in FBC High Velocity Hurricane Zone jurisdictions (i.e., Broward and Miami -Dade Counties).
This Evaluation Report pertains to above -deck roof components. Roof decks and structural members shall be in accordance with
FBC requirements to the satisfaction of the Authority Having Jurisdiction.
This Evaluation Report does not include evaluation of fire classification. Refer to FBC 1505 for requirements and limitations
regarding roof assem bly Ore classification. Refer to FBC 2603 for requirements and limitations concerning the use of foam plastic
insulation.
Polyglass Roof Underlayments may be used with any prepared roof cover where the product is specifically referenced within
FBC approval documents. If not listed, a request may be made to the Authority Having Jurisdiction for approval based on this
evaluation combined with supporting data for the prepared roof covering.
PolysOckMU-Xhaz beenJourW through comparative testlne to have alesserno tlentaJfrv'ctlan than ASrM 0226 rooFn9felt in a drymadltion, testedat standard
labovaforymndltIons. AgroarraMbet soon ponchos.. and sell", as setforth In Secflan 43, Note 3 oFA5TM E,1970.15, should be established os to slip reslston..
REMO ETC, LK.
Certlpmfe of,UMorization a31455 7- EOmON 2020 FRC NON- Evaluation Report P1Z06 F1.5259-RZ9
HVHZints EVALUATION FL529a-R20
Polyglass Roof Underlaymerda Revision 27: 09/30/2020
Page 4of 17
6.6 Allowable Roof Covers: ONEIVIO I etc.
TABIE I: ROOF COVER OPTIONS
Asphalt
Cleyand Cencretenle
Metal
am.
Undedaymnent
Shingles
NwPa)
saite-Tm
Wood
Meehankal
Adhesive.
Panek
Shlrgle6
Shkw.
Shngles
Attach
Set
lES 4
(107.51
05071)
fg5a121
ShalumptWg)
Elastobase
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Wlemamb
nII6, iyHlll
W.a".1
Inamesu ,
(µemabb
Ipheman.
(...b
uhunnampYM,
IlJumelem o336,
See see)
6ees.631
nII6.TyWll1
sons"xxio
UR6,'ne"I
Typelll
Type lh
Elastobase P
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
W nmt<
p334MeYl
Wa.aneL
ow.1nex,
Parcmne.
unwM<em
IAinmuiem
unemn.m02M
ul^en°3e
ses.&3)
6ee5831
o3M,T3venl
o336,1Y 11)
pRa,Tsvell)
T3neef
Ivu
rype111
Polyglass Base
No
Yes
Yes
Wevesnen,
Iazaxval
No
No
No
No
No
sx683)
sees.t31
P.Ini.ss G2 Base
No
Yes
Iazamanxe,
Yes
(eaxshex
No
No
No
No
sxs.gN
sxxe3l
No
Elastuflex S6G
No
Yes
Yes
No
No
(see5A2)
No
Na
No
EWa 011"56G FR
No
Yes
No
No
No
No
No
No
Hyd.Guafd Dual Pro
Yes
No
No
Yes
Yes
Yes
Yes
Yes
ln1M $IR.SSOT.t13
gtlrRneps, 15a,113
/IWs.1.131
/R9Pi.1.1.31
HydraGuard Tile Pro
Yes
Yes
Yes
Yes
Yes
Yes
Yen
Yes
(See5.6.1)
"MvnMu03.113
Wntvm I%7.113
/0.9a5.1131
/pVs.1.13)
Mule -Hide SA-APP Cap Sheet
No
Yes
Yes
No
No
I3eese.1)
No
No
No
Mule -Hide SA-APP Dap Sheet (FR)
No
Yes
Yes
No
(See 5.6.1)
No
No
No
No
Polyflex G
No
Yes
Yes
No
No
N0
(See5.6.1)
No
No
Polyflex G FR
No
Yes
No
N0
No
No
No
No
Polyflex SAP
N0
Yes
YB5
No
No
No
No
(See5.6.1)
No
Polyflex SA P FR
No
Yes
Yen
No
No
No
Ove5k.1)
No
No
Pol stick lR-Xe
Y
Yes
No
No
No
No
Yes
Yes
Yes
Poe-P,asn)113
gdmeuo,,ssm.iu
/0.ffis.LM)
/P335]].3)
Polstick NITS Plus
Y
Yes
Yes
No
Yes
Yes
Yes
Yes
Yes
IldMnnPe, Lw6313
(gmmblx, vse1113
/asa.1131
/R415113)
POlystick MU-X
Yes
No
No
Yes
Yes
Yes
Yen
Yes
IWMNgu, 15%.1.1a
gdMnryy15N.113
/19351131
/p9M.113)
Polystick TU Max
No
Yes
Yes
Yen
Yes
No
Yes
Yen
(See 5.6.1)
dmnax,3Wl1L3
gaietabiP; 15%113
/6sns3.u)
/reus.1.1.31
Polystick TUP
No
Yes
Yes
No
No
No
Yes
Yes
(Sees.6.1)
(gM[ne111[150).1.1.3
OeM WIps, 15N].a3
/reos.la.31
/wosa1.3
Polyetick TU Plus
Yen
Yes
Yes
Yes
Yes
Yen
Yes
Yes
(See 5.6.1)
gppnSMry,ssW.113
Odmnrps, l5oT.1.13
/fWs.l.1.31
/R905.1.131
Pol stick XFR
Y
Yes
Yes
No
Yes
Yes
Yes
Yen
Yes
Odmaax, LAn.113
OdMsmaz,ssM113
J .'")
/R90533.M
NEMO ETC, LLC.
CertiT.o7AuoYotleatkn#32Ais YTM EDRION 2020 FBC NON- Evaluation Report P3206 F 2 59-B2T
( ( NVyments UATH)N FL/30/2031
Polyglass Roof Underlayments Revision 27: 09/30/2020
Page 5 of 17
5.6.1 Adhesive -set tile is limited to use of the following underlavrnant /tila_oAHue:.,e .,.....:__.:-__ W NEMO j etc.
TABLE 1A: ALLOWABLE UNDERIA MENT/TILE-ADMUM COMBINATION5a
Und=SA
Adhesive
Florida Product Approval
Pnlystick TU Max or Polystick TU PlusDAP
Foam "Touch'n SealStormBond
Roof Tile Adhesive"
FL14506HydraGuard
Tile Pro, PolyflaxSA P, Pololystick TU P or Polystick
Dupont"Tile Bond"' Roof TileTU
PlusAdhesive"
FL22525
ElastaFlex S6 G, HydraGuard Tile Pro, MP Cap Sheet, Mule -Hide SA-
APPCapSheet(FR),Polytlex G, POIyFleA P FR, Polystick% Max,
ICPAdhesives and SealantsPolystick
TU P or Polystick TU plus'Polyset•
AHS60"
ElastoFlex S6 G, HydraGuard Tile Pro, Mue-eSA-APP Cap Sheet, Mule -Hide SA-
APP Cap Sheet (FR), PolyFlex G, PolYH-SA P, Polyflex SA P FR, Polystick TU Max,
ICP Adhesives and Sealants
Polystick TU P or Polystick TU Plus
"POlyset• RTA-1"
FW276
5.7 Allowable Substrates:
TABLE 2: SUSSMU OPTIONS FOR ADHERED UNDERLAYMEM
Underlayment
HydraGuard Dual Pro,
HydaGuard Tile Pro, Polystick lR-
Xe, Polystick MTS Plus, Polystick
MU-X, Polystick TU Max,
Polystick TU P, Polystick TU Plus,
Polystick XFR, Mule -Hide SA-APP
Cap Sheet, Mule -Hide SA-APP
Application
self
adhering
g
Substrates (designed
to meet wind loads for project)
Type
Deck/
sheathing
Primer
(Optional) ASTM
D41
MMeNaI(s)
Plywood,OSB, Southern yellow Pine or Huber Engineered
Woods ZIP System"Panels
ASTM D41
structural wn<rete
Insulation
(Optional)ASTM
D41 or WB-3000
ASTMC1299 Type 11 Class l polyisocyanurate, ASTM
C1289 Type V polyisccyanurute-composite, DenSDeck
Prime or SECUROCK Gypsum -Fiber Roof Board
Cap Sheet (FR), Poh/Flex SA P or
PolyFlex SA P FR
Base Sheet
N/A
ASTM D226, Type II deli, Elastobase, Elastobase P or Mule-
Hide Nall Base
Deck
ASTM D41
structural concrete
Elast flex S6 G or Elastoflex S6G
hetasphak
Insulation
(Optional)ASTM
D41
Dens0eck Prime or SECUROCK Gypsum -Fiber Fiber Roof Board
Base Sheet
N/A
ASTM D226, Type II felt, Elastobase, Elastobase P, Mule -
Hide Nail Base or Polyglass G2 Base
Deck
ASTM D41
structural concrete
PolyFlexG or PolyflexG FR
torch-
applied
Insulation
(Optional)ASTM
D41
DensDeck Prime or SECUROCK Gypsum -Fiber Roof Board
Base Sheet
N/A
Eobase, Elastobase P, Mule -Hide Nail Base, Polyglass
G2lastBase Or Polyglass Base
2 Refer to Tile Manufacturer's or Adhesive Manufacturer's Florida ProductAPProvalfor Overturning Moment Resistance Performance.
NEMO ETC, I.I.C.Evaluation Report PnW.02.09-R27
Oara$m1en7Auffi aae32455 7^ EDITION (2020) FBC NON-HVHZ EVALUATION FB259-01
Polyglass Roof UndeNaymenb Re si0n 27: 09130/20ZO
Page 6 0117
5.8 Attachment Limitations, ®NEMO I etc.
5.8.1 For use under mechanically attached NON -TILE prepared roof coverings, attachment shall be in accordance with the
manufacturer's installation instructions, but —for mechanically attached underlayments or base sheets - not less than FBC
1507.1.1 or 11905.1.1.
5.8.2 For use under tile roof systems, attachment shall be in accordance with the manufacturer's installation instructions, but —
for mechanically attached base sheets - not less than:
• FRSA/TRI Florida High Wind Concrete and Clay Roof Tile Installation Manual, Sixth Edition, Appendix A, Table 1 (for Two -
Ply Asphalt Applied Hot Mop Underlayment)
or
• Section 5.8.3 herein (for other underlayment systems).
5.8.3 Wind Resistance for UnderlaymentSystems in T'lle Roof Appl' tons:
The following wind uplift limitations apply to underlayment systems that are not prescriptive in the FRSA/TRI Florida High
Wind Concrete and Clay Roof Tile Installation Manual, Sixth Edition. The Maximum Design Pressure is the result of testing
for wind load resistance based on allowable wind loads, and reflects the ultimate passing pressure divided by 2 (the 2 to 1
margin of safety per FBC 1504.9 has already been applied).
5.8.3.1 Direct -to -Deck:
The maximum design pressure for the selected assembly shall meet or exceed that required under FRSA/TRI Florida High
Wind Concrete and Clay Roof Tile Installation Manual, Sixth Edition, Appendix A, Table 3A or the critical (highest) design
Pressure determined in accordance with FBC 1609 or FBC Residential Chapter 3.
#1 Maximum Design Pressure =-52.5 psf:
Deck: APA rated,7/16 CAT,0.418 in., Exposure 1, 058 sheathing to meet project requirements to satisfaction of Authority Having
Jurisdiction.
Joins: Min. 4-inch wide strips of Elastoflex SA-V over all OSB joints
Base Ply: Polystick MTS Plus, self -adhered.
Underlayment: Mule -Hide SA-APP Cap Sheet, Mule -Hide SA-APP Cap Sheet (FRI, Polyflex SA P, POlyflex SA P FR, Polystick TU Max, Polystick
TU P or Polystick TU Plus, self -adhered.
#2 Maximum Design Pressure =-90 sf:
Deck: MIn.15/32-inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction.
Primer: None
Base Ply: (Optional) Polystick MIS Plus, self -adhered.
Underlayment Mule -Hide SA-APP Cap Sheet, Mule -Hide SA-APP Cap Sheet (FR), Polyfiex SA P, Polyflex SA P FR, Polystick TU Max, Polystick
TU P or Polystick TU Plus, self -adhered.
#3 Maximum Design Pressure =.975 PsC
Deck: Min.15/32-Inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction.
Primer: PG1W or ASTM D41
Base Ply: (Optional) Polystick MTS Plus, self -adhered.
Underlayment: Mule -Hide SA-APP Cap Sheet, Mule -Hide SA-APP Cap Sheet FR), Polyflex SA P, Polyflex SA P FR, Polystick TU Max, Polystick
TU P or Polystick TU Plus, self -adhered and back -nailed within the selvedge -edge side laps using 12 ga. x 1X' ring shank
nails through 32 ga.,1-5/9- diameter tin ups spaced 12-inch o.c.
44 Maximum Design Pressure =-105 Psf,
Deck: Min.15/32-inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction.
Primer: W8-3000
Base Ply: (Optional) Polystick MTS Plus, self -adhered.
Underlayment Mule -Hide SA-APP Cap Sheet, Mule -Hide SA-APP Cap Sheet (FR), Polyflex SA P, Polyflex SA P FR, Polystick TU Max, Polystick
TU P or Polystick TU Plus, self -adhered and back -nailed within the selvedge -edge side laps using 12 ga. x 13C ring shank
nails through 32 ga.,1-5/8' diameter tin caps spaced 12-Inch o.c.
REMO ETC, U.C. Evaluation Report P12060.02.09-R37
Csrrft.r of gaNaruerb1#32455 7- E0m[ON 120Z01 FBC NONMVHZ EVALUATION FL5259,ul
Polyglass Roof Undedayments Revision 27: 09/30/2020
Page 7 of 17
#5 Maximum Design Pressure = .111osf: NNEMOJetc.
Deck: MIn.15/32-inch plywood to meet project requirementsto satisfaction of Authority Having Jurisdiction.
Primer: (Optional) PG100 or ASTM D41
Base Ply: (Optional) Polystck Mrs Plus, self -adhered.
Joints: Min. flinch wide strips of ElwtoflexSA-V over all Plywood joints.
Undedayment Mule -Hide SA-APP Cap Sheet, Mule -Hide SA-APP Cap Sheet (FRI. Polyflex SA P, Polyflex SA P FR, Polystick TU Max, Polystick
TU P or Polystick TU Plus, self -adhered.
#6 Maximum Design Pressure . -315 Mf:
Deck: Structural concrete to meet project requirements to satisfaction of Authority Having Jurisdiction.
Primer: PG300 or ASTM D41
Base Ply: (Optional) Polystick NITS Plus, self -adhered.
Underlayment: HydreGuard Tile Pro, Mule -Hide SA-APP Cap Sheet, Mule -Hide SA-APP Cap Sheet (Fit), Polyflax SA P, Polyflex SA P FR,
Polystick TU Max, Polystick TU P or Polystick TU Plus, self -adhered.
#7 Maximum Design Pressure =-6225 psf:
Deck: Structural concrete to meet Project requirements to satisfaction of Authority Haying Jurisdiction.
Primer: PG100 of ASTM D41
Underlayment: Elastoflex S6 G, applied in full mopping of hot asphalt or Polyflex G, torch -applied.
#8 All other direct -deck, adhered underlayment systems beneath tile roof systems carry a Maximum Design Pressure of.45 psf.
5.8.3.2 Mechanically -Attached Base Sh t:
The maximum design pressure for the selected assembly shall meet or exceed that required under FRSA/TRI Florida High
Wind Concrete and Clay Roof Tile Installation Manual, Sixth Edition, Appendix A, Table IA or the critical (highest) design
pressure determined in accordance with FBC 1609 or FBC Residential Chapter 3.
Alternatively, the maximum design pressure for the selected assembly shall meet or exceed at least the Zone 1 design
pressure determined in accordance with FBC 1609 or FBC Residential Chapter 3. Elevated pressure zones shall employ an
attachment density designed by a qualified design professional to resist the elevated pressure criteria. Commonly used
methods are ANSI/SPRI WDS, FM Loss Prevention Data Sheet 1-29, Roofing Application Standard RAS 117 and Roofing
Application Standard RAS 137. Assemblies marked with an asterisk` carry the limitations set forth in Section 2.2.10.1 of FM
Loss Prevention Data Sheet 1-29 (February 2020) for enhancements.
#9 Maximum Design Press =-30 0 f•:
Deck: Min.15/32-Inch OSB to meet project requirements to satisfaction of Authority Having Jurisdiction,
Base Sheet: Elastobase or Mule -Hide Nail Base (poly -film top surface)
Fasteners: 11 ga. x 1.25-Inch long x 1-inch head diameter round metal up nails
Spacing: 6-inch o.c. at the 3-inch wide side laps and 6-inch o.c. at two (2) equally spaced staggered center rows.
Base Ply: (Optional) Polystick MTS Plus, self -adhered.
Underlayment; Mule -Hide SA-APP Cap Sheet, Mule -Hide SA-APP Cap Sheet (Fit), Polyflex SA P, Polyflex SA P FR, Polystick TU Max, Polystick
TU P or Polystick TU Plus, self -adhered.
#10 Maximum Design Pressure =-375 PsP:
Deck: Min.15/32-inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction.
Base Sheet: Elastobase or Mule -Hide Nail Base(poly-fllm top surface)
Fasteners: 11 ga.x 1.25-Inch long 1-inch head diameter round metal cap nails
Spacing: 6-inch o.c. at the 34rich wide side laps and 6-inch o.c. at two (2) equally spaced staggered center rows.
Base Ply: (Optional) Polystick NITS Plus, self -adhered.
Underlayment: Mule -Hide SA-APP Cap Sheet, Mule -Hide SA-APP Cap Sheet (Hit), Polyflex SA P, Polyflex SA P Fit, Polystick TU Max, Polystick
TU P or Polystick TU Plus, self -adhered.
#I1 Maximum Design Pressure =-375 OSP:
Deck: MIn.19/32-inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction.
Base Sheet: One (1) or two (2) layers ASTM D226, Type II felt
Fasteners: 11 ga. x 1.25-Inch long x 1-Inch head diameter round meal up falls
Spacing: E inch o.c. at the 3-inch wide side laps and 12-inch D.C. at two (2) equally spaced staggered center rows.
Underlayment Elastoflex S6 G, applied in full mopping of hot asphalt.
NEMO ETC, LLG Evaluation Report P32060.02.09-R27
Ondiww nfAutawuarun#32455 7r'EDITION (2020)FBE NON-WHZ EVALUATION Ft5259ltll
Polyglass Roof Undedaymems Revision 27: 0/30/20ZO
Page 8 0 17
#12 Maximum Design Pressure =d5 psfe: NNEMO I etc.
Deck: Min.19/32-inch Plywood to meet project requirements to satisfaction of Authority Having Jurisdiction.
Base Sheet: One (1) layer ASTM D226, Type II felt
Fasteners: 11 ga. x 1.25-Inch x 3/8-Inch head diameter annular ring shank roofing nails at 1-5/8 inch diameter tin caps
Spacing: &inch o.c. at the 2-inch wide side laps and 4-inch o.c. at two (2) equally spaced staggered center rows.
Base Ply: (Optional; for use with self -adhering underlayment only) Polystick MTS Plus, self -adhered.
Underlayment Mule -Hide SA-APP Cap Sheet, Mule -Hide SA-APP Cap Sheet (FRI, Polyflex SA P, Polyflex SA P FR, Polystick TU Max, Polystick
TU P or Polystick M Plus, self -adhered.
#13 Maximum Design Pressure =fi5 osP:
Deck: Min.19/32-Inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction.
Base Sheet: Two (2) layers ASTM D226, Type II felt
Fasteners: 11 ga. x 1.25-inch long x 3/8-inch head diameter annular ring shank roofing nails at 1-5/84nch diameter tin caps
Spacing: 9-Inch O.C. at the 2-inch wide side laps and 9-inch o.c. at two (2) equally spaced staggered center rows.
Base Ply: (Optional; for use with self -adhering underlayment only) Polystick MTS Plus, self -adhered.
Underlayment Mule -Hide SA-APP Cap Sheet, Mule -Hide SA-APP Cap Sheet (FR), Polyflex SA P, Polyflex SA P FR, Polystick M Max, Polystick
TU P or Polystick M Plus, self -adhered or Elastoflex S6 G, applied In full mopping of hat asphalt.
#14 Maximum Design Pressure =-45 DsE
Deck: Min.15/32-Inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction.
Base Sheet: Elastobase(sanded top surface for hot -asphalt or torch -applied cap or Poly -film surface for torch -applied cap)
Fasteners: Simplex MAXI( Cap Fasteners
Spacing: 9-inch o.c. at the 2-inch wide side laps and 18-inch o.c. at two (2) equally spaced staggered center rows.
Underlayment: Elastoflex S6 G, applied In full mopping of hat asphalt or Polyflex G, torch -applied.
#15 Maximum Design Pressue-4S0Dsf:
Deck: APA rated,7/16 CAT,0.418 in., Exposure 1, OSB sheathing to meet project requirements to satisfaction of Authority Having
Jurisdiction.
Base Sheet: Elastobase or Mule -Hide Nail Base(poly-film top surface)
Fasteners: 12 ga, annular ring shank nails with 1-5/8" diameter tin caps
Spacing: 6-inch O.C. at the 3-inch wide side laps and &inch o.c. at four (4) equally spaced staggered center rows.
Base Ply: (Optional) Polystick MTS Plus, self -adhered.
Underlayment: Mule -Hide SA-APP Cap Sheet, Mule -Hide SA-APP Cap Sheet (Fit), Polyflex SA P, Polyflex SA P FR, Polystick TU Max, Polystick
TU P or Polystick TU Plus, self -adhered.
#16 Maximum Design Pressure =-050 f:
Deck: APA rated, 7/16 CAT, 0.418 in., Exposure 1, OSB sheathing to meet project requirements to satisfaction of Authority Having
Jurisdiction.
Base Sheet Elastobase(sand top surface)
Fasteners: 12 ga. annular ring shank nails with 1-5/8" diameter tin raps
Spacing: &inch o.c. at the 3-Inch wide Side laps and 6-incho.c. at four(4) equally spaced staggered center rows.
Underlayment Elastoflex S6 G, applied in full mopping of hot asphalt.
#17 Maximum Design Pressure --450gsf:
Deck: APA rated,7/16 CAT,0.418 in., Exposure 1, OSB sheathing to meet project requirements to satisfaction of Authority Having
Jurisdiction.
Base Sheet: Elastobase or Polygiass Base
Fasteners: 12 ga. annular ring shank nails with 1-5/8" diameter tin caps
Spacing: 6-inch D.c. at the 3-inch wide side laps and 6-inch o.c. at four(4) equally spaced staggered center rows.
Underlayment: Polyflex G, torch -applied.
#18 Maximum Design Pressure =-525 Dsf:
Deck: MIn.15/32-Inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction.
Base Sheet: Elastobase(sanded top surface for hot -asphalt ortorch-applied cap or poly -film surface for torch -applied up)
Fasteners: Simplex MAXX Cap Fasteners
Spacing: 9-inch o.c. at the 2-inch wide side laps and 12-inch o.c. at two (2) equally spaced staggered center rows.
Underlayment Elastoflex 56 G, applied in full mopping of hot asphalt or Polyflex G, torch -applied.
NEMO ETC, LLG Evaluation Report P12060.02.09-R27
Certificate O7Amlmrrm.02N 7TH EDITION (2020) FBC NON.HVHZ EVALUATION FL5259.R31
Polyglass Roof Undedaymeme Revision 27: 09/30/2020
Page 9.f17
#19 Maximum DesienP ess a=-525 sf: ONEMOjetc.
Oeck: MIn.15/32-inch plywood to meet project requirementsto satisfaction Of Authority Having Jurisdiction.
Base Sheet: Elastobase or Mule -Hide Nail Base (Poly -film top surface)
Fasteners: Simplex Original Cap Nails
Spacing: 6-inch o.c. at the 3-Inch wide side laps and 6-inch o.c. at four (4) equally spaced staggered center rows.
Base Ply: (Optional) Polystick MTS Plus, self -adhered.
Underlayment Mule -Hide SA-APP Cap Sheet, Mule -Hide SA-APP Cap Sheet (Fit), Pnlyflex SA P, Polyflex SA P Fit, Polystick TU Max, Polystick
TU P or Polysdck TU Plus, self -adhered.
#20 Maximum Design Pressure = -52.5 psf:
Deck: MIn.15/32-inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction.
Base Sheet: Elastobase(sanded tap surface for hot -asphalt or torch -applied cap or poly -film surface for torch -applied cap)
Fasteners: Simplex Original Cap Nails
Spacing: 6-inch o.c. at the 3-inch wide side laps and 6-inch O.C. at four (4) equally spaced staggered center rows.
Underlayment: Elastoflex Sb G, applied in full mopping of hot asphalt or Polyflex G, torch -applied.
#21 Maximum Design Pressure - -60 of:
Deck: Min.19/32-inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction.
Base Sheet: Elastobase(sanded top surface for hot -asphalt or torch -applied cap or Poly -film surface for torch -applied cap)
Fasteners: 11 ga. x 1.25-inch long x 3/8-inch head diameter annular ring shank roofing nails at 1-5/8-inch diameter tin caps
Spacing: 8-Inch o.c. at the 4-inch wide side laps and 8-inch o.c. at three (3) equally spaced staggered center rows.
Underlayment Elastoflex S6 G, applied in full mopping of hot asphalt or Polyflex G, torch -applied.
#22 Maximum Design Pressure =-60 psf:
Deck: Min.19/32-inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction.
Base Sheet Elastobase(sanded top surface for hot -asphalt or torch -applied cap or poly -film surface for torch -applied cap)
Fasteners: OMG #12 Standard Roofgrip with OMG Fiat Bottom Metal Plates
Spacing: 12-inch o.c. at the &Inch wide side laps and 12-Inch o.c. at two (2) equally spaced staggered center rows.
Underlayment: Elastoflex S6 G, applied in full mopping of hot asphalt or Polyflex G, torch -applied.
#23 Maximum Design Press =-600 osf:
Deck: APA rated,]/16 CAT,0.418 in., Exposure 1, OSB sheathing to meet project requirements to satisfaction of Authority Having
Jurisdiction.
Base Sheet: Elastobase or Mule -Hide Nail Base (poly -film top surface)
Fasteners: Simplex MA Cap Fasteners
Spacing: 8-Inch o.c. at the 34ach wide side laps and 8-inch o.c. at three (3) equally spaced staggered center rows.
Primer: PG 100 or ASTM D41 primer applied to stress plates.
Base Ply: (Optional) Polystick MTS Plus, self -adhered.
Underlayment: Mule -Hide SA-APP Cap Sheet, Mule -Hide SA-APP Cap Sheet (Fit), Polyflex SA P, Polyfiex SA P FR, Polystick TU Max, Poh/stick
TU P or Polystick TO Plus, self -adhered.
#24 Maximum Design Pressure = -60.0 osf:
Deck: APA rated, ]/16CAT, 0.418 in., Exposure 1, 05B sheathing to meet project requirements to satisfaction of Authority Having
Jurisdiction.
Base Sheet Elastobase(sand top surface)
Fasteners: Simplex MAXX Cap Fasteners
Spacing: 8-inch o.c. at the 3inch wide side laps and 8-inch o.c. at three (3) equally spaced staggered center rows.
Underlayment: Elastoflex S6 G, applied in full mopping of hot asphalt.
#25 Maximum Design Pressure - -0.0 osf:
Deck: APA rated, /16CAT, 0.418 in., Exposure 1, OSB sheathing to meet project requirements to satisfaction of Authority Having
Jurisdiction.
Base Sheet: Elastabase Or Polyglass Base
Fasteners: Simplex MA0( Cap Fasteners
Spacing: 8-inch o.c. at the 3-Inch wide side laps and B-inch o.c. at three (3) equally spaced staggered center rows.
Underlayment: Poh/flex G, torch -applied.
NEMO ETC, LUC. Evaluation Report P12060.02.09 R27
tertif.h,gfAo4m@grloa49a455 TTM EDITION (2020) FBC NON-HVHZ EVALUATION FL5259-R31
Polyglass ROOF Uoderlayments Revision 27: 09/30/2020
Page 10 of 17
#26 Maximum Design Pressure =-675 psf: NNEMi
Deck: MIn.15/32-inch plywood to meet project requirement to satisfaction of Authority Having Jurisdiction.
Base Sheet: Polyglass 62 Base or Polyglass Base (requires use of torch applied underlaymem)
Fasteners: 12 ga. x 1.25-Inch long x 3/8-inch head diameter annular ring shank roofing nails at 1-5/8-inch diameter tin caps
Spacing: 8-inch o.c. at the 41nch wide side laps and 8-inch o.c. at four (4) equally spaced staggered center rows.
Underlayment: Elastoflex S6 G, applied in full mopping of hot asphalt or torch -applied or Polyflex G, torch -applied.
#27 Maximum Design Pressure =47 5 Dsf:
Deck: APA rated, 19/32 CAT, 0.578 in., Exposure 1, OSB sheathing to meet project requirements to satisfaction of Authority
Having Jurisdiction.
Base Sheet: Elastobase or Mule -Hide Nall Bass (Poly -film top surface)
Fasteners: TRUFAST Versa -fast Fasteners & Plates with two (2) screws per plate installed 180' into the holes of the plate, parallel to
the width direction of the sheet.
Spacing: 12-inch o.c. at the flinch wide side laps and 12-Inch O.C. at two (2) equally spaced staggered center rows.
Primer: (Optional) PG300 or ASiM 041 primer applied to stress plates.
Base Ply: (Optional) Polystick NITS Plus, self -adhered.
Underlayment Mule -Hide SA-APP Cap Sheet, Mule -Hide SA-APP Cap Sheet (FR), Poyflex SA P, Polyflex SA P FR, Polystick TU Max, Polystick
TU P or Polystick TU Plus, self -adhered.
#28 Maximum Design Press =-675 Dsf:
Deck: APA rated, 19/32 CAT, 0.578 in., Exposure 1, OSB sheathing to meet project requirements to satisfaction of Authority
Having Jurisdiction.
Base Sheet Elastobase (sand top surface)
Fasteners: TRUFAST Versa -fast Fasteners & Plates with two (2) screws per plate installed 180' Into the holes of the plate, parallel to
the width direction of the sheet.
Spacing: 12-Inch O.C. at the 4-inch wide side laps and 12-inch o.c. at two (2) equally spaced staggered center rows.
Underlayment: Elastoflex S6 G, applied in full mopping of hot asphalt.
#29 Maximum Design Press ={7 5 DO:
Deck: APA rated, 19/32 CAT, 0.S78 in., Exposure 1, OSB sheathing to meet project requirements to satisfaction of Authority
Having Jurisdiction.
Base Sheet: Elastobase or Polyglass Base
Fasteners: TRUFAST Versa -Fast Fasteners & Plates with two (2) screws per plate installed 180' into the holes ofthe plate, parallel to
the width direction of the sheet.
Spacing: 12-Inch o.c. at the 44nch wide side laps and 12-inch O.C. at two (2) equally spaced staggered center rows.
Underlayment Polyflex G, torch -applied.
#30 Maximum Design Pressure --75 Dsf:
Deck: Min.15/32-inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction.
Base Sheet: Polyglass 62 Base or Polyglass Base (requires use of [arch -applied undedgyment)
Fasteners: Dekfast#14 with Dekfast Hex Plates, OMG#14 HD with OMG 3" Galvalume Steel Plates, OMG Roofgrip#14 with OMG Flat
Bottom Plates (AccuTrach Trufast HD with Trufast 3-inch Insulation Plates or Simplex MAX)( Cap Fasteners
Spacing: 104nch o.c. at the flinch wide side laps and 10-inch o.c. at three (3) equally spaced staggered center rows.
Underlayment Elastoflex S5 G, applied in full mopping of hot asphalt or torch -applied or Polyflex G, torch -applied.
#31 Maximum Design Press =-90 PsE
Deck: Min.35/32-inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction.
Base Sheet: Elastobase(sanded top surface for facasphalt or torch -applied cap or poly -film surface for torch -applied rap)
Fasteners: Simplex MAXX Cap Fasteners
Spacing: 6-inch o.c. at the 2-Inch wide side laps and 6-inch o.c. at two (2) equally spaced staggered center rows.
Underlayment: Elastoflex 56 G, applied in full mopping of hot asphalt or Polyflex G, torch -applied.
#32 Maximum Design Pressure =-90Dsf:
Deck: MIn.15/32-inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction.
Base Sheet: Elastobase(sanded tap surface for hot -asphalt or torch -applied up or poly -film surface for torch -applied cap)
Fasteners: OMG #12 Standard Rcofgdp or OMG #14 Heavy Duty with OMG 3" Round Metal Plates or OMG Flat Bottom Metal Plates
Spacing: 6-Inch o.c, at the 4-inch wide side laps and 5-inch o.c. at three (3) equally spaced staggered center rows.
Underlayment: Elastoflex S6 G, applied In full mopping of hot asphalt or Polyflex G, torch -applied.
NEMO FrC, LLD. Evaluation Report P12060.02.09-1127
CotipmceofAvthonzaamitcaxs 7TM EDITION (2020) FBE NON.HVHZ EVALUATION FL5259-R31
Polyglass Roof Undedaymems Revision 27: 09/30/3020
Page 11 of 17
#33 Maximum Design P =-90 f: ONEMOletc.
Deck: Min.15/32-Inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction.
Base Sheet: Elastobase(sanded top surface)
Fasteners: Trufast#12 DP or Trufast#14 HD with Trufast 3" Metal Insulation Plates
Spacing: 6-inch o.c. at the 4-Inch wide side laps and &inch o.c. at three (3) equally spaced staggered center rows.
Underlayment: Elastoflex S6 G, applied In full mopping of hot asphalt
#34 Maximum Design Pressure --90 psf:
Deck: Min.15/32-inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction.
Base Sheet: Polyglass G2 Base or Polyglass ease (requires use of torch -applied Underlayment)
Fasteners: Dekfast#14 with Dekfast Hex plates, OMG #14 HD with OMG 3" Galvalume Steel Plates, OMG ROOfgnp#14 with OMG Flat
Bottom Plates(ACCOTrac), Trufast HD with Trufast 3-inch Insulation Plates or Simplex iy J Cap Fasteners
Spacing: 9-Inch o.c. at the flinch wide side laps and 9-inch O.C. at four (4) equally spaced staggered center rows.
Underlayment: Elartaflex S6 G, applied In full mopping of hot asphalt or torch -applied or Polyflex G, torch -applied.
#35 Maximum Design Pressure =-900 psf:
Deck: APA rated,7/16 CAT,0.418 in., Exposure 1, OSB sheathing to meet project requirements to satisfaction of Authority Having
Jurisdiction.
Base Sheet: Elastobase or Mule -Hide Nail Base (Poly -film top surface)
Fasteners: TRUFAST Versa -Fart Fasteners & Plates with two (2) screws per plate installed 1800 into the holes of the plate, parallel to
the width -direction of the sheet
Spacing: 9-inch O.C. at the 2-Inch wide side laps and 12-inch o.c. at two (2) equally spaced staggered center rows.
Primer: PG10O or ASTM D41 primer applied to stress plates.
Base Ply: (Optional) Polystick MTs Plus, self -adhered.
Underlayment: Mule -Hide SA-APP Cap Sheet, Mule -Hide SA-APP Cap Sheet (FIR), Polyflex SA P, Polyflex SA P FR, Polystick TU Max, Polystick
TU P or Polystick TU Plus, self-atlhered.
#36 Maximum Design Pressure =-900 psf:
Deck: APA rated,7/16 CAT,0.418 in., Exposure 1, OSB sheathing to meet project requirements to satisfaction of Authority Having
Jurisdiction.
Base Sheet Elastobase (sand top surface)
Fasteners: TRUFAST Versa -Fast Fasteners & Plates with two (2) screws per plate installed 18W into the holes of the plate, parallel to
the width -direction of the sheet
Spacing: 9-inch o.c. at the 2-inch wide side laps and 12-inch o.c. at two (2) equally spaced staggered center rows.
Underlayment ElastoBex S6 G, applied in full mopping of hat asphalt.
#37 Maximum Design Pressure =-900 psf:
Deck: APA rated,7/16 CAT,0.418 in., Exposure 1, OSB sheathing to meet project requirements to satisfaction of Authority Having
Jurisdiction.
Base Sheet Elastobase or Polyglass Base
Fasteners: TRUFAST Versa -Fast Fasteners & Plates with two (2) screws per plate installed I80° into the holes of the plate, parallel to
the width-direcdon of the sheet
Spacing: 9-inch o.c. at the 2-inch wide side laps and 12-inch o.c. at two (2) equally spaced staggered center rows.
Underlayment: Polyflex G, torch -applied.
#38 Maximum Design Press --975 O:
Deck: Min.19/32-Inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction.
Base Sheet Elastobase or Mule -Hide Nall Base (poly -film top surface)
Fasteners: 11 ga, x 1.25-inch x 3/8-inch head diameter annular ring shank roofing nails at I-5/8-inch diameter tin caps
Spacing: 4-inch o.c. at the 4-inch wide side laps and 4-inch o.c. at four (4) equally spaced staggered center rows.
Base Ply: (Optional) Polystick NITS Plus, self -adhered.
Underlayment: Mule -Hide SA-APP Cap Sheet, Mule -Hide SA-APP Cap Sheet (FR), Polyflex SA P, Polyflex SA P FIR, Polystick TU Max, Polystick
TU P or Polystick TU Plus, se# -adhered.
NEMO ETC, UC. Evaloallon Report P12060.02.09 RZ7
lerafkate ofAVMPtlMion #32455 PEDITION (2020)FBC NON-HVHZ EVALUATION FL5259-R31
Polyglass Roof UMerlayments Revision 27: 09/30/20ZO
Page 12 of 17
#39 Maximum Desien P sure = A7 5 laid:: ONEI'lil
Deck: APA rated, 19/32 CAT, 0.578 in., Exposure 1, OS8 sheathing to meet project requirements to satisfaction of Authority
Having Jurisdiction.
Base Sheet- Elastobase or Mule -Hide Nail Bass (poly -film top surface)
Fasteners: Simplex MAXXCap Fasteners
Spacing: 6-Inch o.c. at the flinch wide side laps and 6-inch O.C. at four (4) equally spaced staggered center rows.
Primer: PG100 or ASTM D41 primer applied to stress plates.
Base Ply: (Optional) Polystick MTS Plus, self -adhered.
Underlayment: Mule -Hide SA-APP Cap Sheet, Mule -Hide SA-APP Cap Sheet (Fit), Polyflex SA P, P0lyflex SA P FR, Polystick TU Max, Poh/stick
TU P or Polystick TU Pius, self -adhered.
#40 Maximum Design Press - -975 nsf.,
Deck: APA rated, 19/32 CAT, 0.578 in., Exposure 1, OSB sheathing to meet project requirements to satisfaction of Authority
Havinglurisi iction.
Base Sheet: Elastobase(sand top surface)
Fasteners: Simplex Ml Cap Fasteners
Spacing: 6-inch o.c. at the 4-inch wide side laps and 6-inch o.c. at four (4) equally spaced staggered center rows.
Undedayment- Elastoflex S6 G, applied in full mopping of hot asphalt.
#41 Maximum Design Pressure =-975 all
Deck: APA rated, 19/32 CAT, 0.578 In., Exposure 1, OSB sheathing to meet project requirements to satisfaction of Authority
Having Jurisdiction.
Base Sheet: Elastobase or Polyglass Base
Fasteners: Simplex MAXX Cap Fasteners
Spacing: 6-inch O.C. at the 4-inch wide side laps and 6-inch o.c. at four (4) equally spaced staggered center rows.
Underlayment: Poll G, torch -applied.
#42 Maximum Design Pressure =-105 lal
Deck: Min.15/32-inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction.
Base Sheet: Elastobase(sanded top surface for hot -asphalt or torch -applied cap or poly -film surface for torch -applied cap)
Fasteners: Simplex MAXX Cap Fasteners
Spacing: 6-inch o.c. at the 2-inch wide side laps and 6-Inch o.c, at three (3) equally spaced staggered center rows.
Underlayment: Elastoflex 56 G, applied in full mopping of hot asphalt or Polyflex G, torch -applied.
#43 Maximum Design Pressure =-1050 Did:
Deck: APA rated,7116 CAT, 0.418 In., Exposure 1, OSB Sheathing to meet project requirements to satisfaction of Authority Having
Jurisdiction.
Base Sheet: Elastobase or Mule -Hide Nail Base (poly -film top surface)
Fasteners: TRUFAST Versa -Fart Fasteners & Plates with two (2) screws per plate installed 180° into the holes of the plate, parallel to
the width -direction of the sheet
Spacing: &inch o.c. at 4-inch wide side laps and 6-Inch o.c. at three(3) equally spaced staggered center rows.
Primer: PG300 or ASTM D41 primer applied to stress plates.
Base Ply: (Optional) Polystick MTS Plus, self -adhered.
Underlayment: Mule -Hide SA-APP Cap Sheet, Mule -Hide SA-APP Cap Sheet (Fit), Polyflex SA P, Polyflex SA P FR, Polystick TU Max, Polystick
TU P or Polystick TU Plus, self -adhered.
044 Maximum Design Pressure =-2050 psf:
Deck: APA rated, 7116 CAT, 0.418 In., Exposure 1, 058 sheathing to meet project requirements to satisfaction of Authority Having
Jurisdiction.
Base Sheet: Elastobase(sand top surface)
Fasteners: TRUFAST Versa -Fast Fasteners & Plates with two (2) screws per plate Installed 380° into the holes of the plate, parallel to
the width -direction of the sheet
Spacing: 6-inch o.c. at the 4-inch wide side laps and 6-inch O.C. at three(3) equally spaced staggered center rows.
Underlayment: Elastoflex 56 G, applied in full mapping of hot asphalt.
NEMO ETC, U.C. Evaluation RePint 1`32060.02.09-R27
Roboosu oJAWJxxxakx#32455 7TM EDMON(2020) FBC NON-RVHZ EVALUATION F1.5259-1131
Pull Ronf l.dedavorems Revlaion27:09/30/2020
Page 13 of 17
#45 Maximum Design Pressure =-105 0 Di f: ®NEMO I eft.
Deck: APA rated,7/16 CAT,0.418 in., Exposure 1, OSB sheathing to meet project requirements to satisfaction of Authority Having
Jurisdiction.
Base Sheet: Elastobase or Polyglass Base
Fasteners: TRUFAST Versa -Fast Fasteners & Plates with Two screws per plate installed 180° into the holes of the plate, parallel to
the width -direction of the sheet
Spacing: 6-inch D.C. at the 4-inch wide side laps and 6-inch D.C. at three (3) equally spaced staggered center rows.
Underlayment: Polyflex G, torch -applied.
#46 Maximum Design Pressure - -112.5 ME
Deck: Min.19/32-inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction.
Base Sheet: Elastobase or Mule -Hide Nail Base (poly -film top surface)
Fasteners: 11 ga. x 1.25-inch x3/8-inch head diameter annular ring shank roofing nails at 1-5/8-inch diameter tin caps
Spacing: 6-inch D.C. at the finch wide side laps and 6-inch o.c. at four (4) equally spaced staggered center rows.
Primer: PG100 or ASTM MI primer at all tin -caps
Base Ply: Polystick MTS Plus, self -adhered
Underlayment Mule -Hide SA-APP Cap Sheet, Mule -Hide SA-APP Cap Sheet (FR), Polyflex SA P, Polyflex SA P FR, Polystick TU Max, Polystick
TU P or Polystick TU Plus, self -adhered.
#47 Maximum Design Pressure = -120 sf:
Deck: Min.15/32-Inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction.
Base Sheet Elastobase (sanded top surface for hot -asphalt or torch -applied cap or poly- film surface for torch -applied cap)
Fasteners: OMG #12 Standard Roofgdp or OMG #14 Heavy Duty with OMG 3" Round Metal Plates or DIMS Flat Bottom Meldl Plates
Spacing: 6-inch D.C. at the 4-inch wide side laps and 6-inch D.C. at five (5) equally spaced staggered renter rows.
Underlayment: Elastoflex 56 G, applied in full mopping of hot asphalt or Polyflex G, torch -applied.
#48 Maximum Design Pressure =-220 Dsf:
Deck: Min.15/32-inch Plywood to meet project requirements to satisfaction of Authority Having Jurisdiction.
Base Sheet Elastobase (sanded top surface)
Fasteners: Trufast#12 DP or Trufast#14 HD with Trufast 3" Metal Insulation Plates
Spacing: 6-inch o.c. at the 4-inch wide side laps and 6-inch D.C. at five IS) equally spaced staggered center rows.
Underlayment: Elastoflex S6 G, applied in full mopping of hot asphalt.
949 Maximum Design Press =-127 5 P
Deck: APA rated, 19/32 CAT, 0.578 in., Exposure 1, OSB sheathing to meet project requirements to satisfaction of Authority
Having Jurisdiction.
Base Sheet: Elastobase or Mule -Hide Nall Base (poly -film top surface)
Fasteners: TRUFAST Versa -Fast Fasteners & Plates with one (1) screw per plate, in the center hole.
Spacing: 9-inch D.C. at the 4-inch wide side laps and 9-inch D.C. at four (4) equally spaced staggered center rows.
Primer: PG1DD or ASTM D41 primer applied to stress plates.
Base Ply: (Optional) Polystick MTS Plus, self -adhered.
Underlayment: Mule -Hide SA-APP Cap Sheet, Mule -Hide SA-APP Cap Sheet (FR), Polyflex SA P, Polyflex SA P FR, Polystick TU Max, Polystick
TU P or Polystick TU Plus, self -adhered.
#50 Maximum Design Pressure =-127 5 psf:
Deck: APA rated, 19/32 CAT, 0.578 in., Exposure 1, OSB sheathing to meet project requirements to satisfaction of Authority
Having Jurisdiction.
Base Sheet: Elastobase (sand top surface)
Fasteners: TRUFAST Versa -Fast Fasteners & Plates with one (1) screw per plate, in the center hole.
Spacing: 9-inch D.C. at the 4-Inch wide side laps and 9-inch o.c. at four (4) equally spaced staggered center rows.
Underlayment: Elastoflex 56 G, applied In full mapping of hot asphalt.
#51 Maximum Design Pressure =-1275 Dist:
Deck: APA rated, 19/32 CAT, 0,578 In., Exposure 1, OSB sheathing to meet project requirements to satisfaction of Authority
Having Jurisdiction.
Base Sheet: Elastobase or Polyglass Base
Fasteners: TRUFAST Versa -Fast Fasteners & Plates with one (1) screw per plate, in the center hole.
Spacing: 9-inch D.C. at the 4-inch wide side laps and 9-inch D.C. at four (4) equally spaced staggered center rows.
Underlayment Polyflex G,tomh-applied.
NEW ETC. LLC. Evaluation Report P32060.02.09-R27
Cerririmteu7ANlmnzodga#3]pi5 7"EDITION (2020)FBC NON-HVHZ EVALUATION FB259-891
Polyglass Rod Undedayments Revision 27: 09/30/20M
Page 14 of 17
5.9 Exposure LLimitations- ONEMOjetc.
TAaIE 3: EXPp$pPE tlMrrAmpN$
Underlaymem
Prepared Roof Cover
Maximum
Elastobase, Elastobase P, Polyglass G2 Rase or Polyglass Base
Installation Type
Exposure(days)
Mechanically attached
30
Polystick lR-Xe or Polystick MU-X
Mechanically attached
90
HydraGuard Dual Pro, HydraGuard Tile Pre, Polystick MTS Plus, Polystick TU Max, Polystick
TU P, Polystick TU Plus or Polystick XFR
Any type (per Table 1)
1gp
Elartoflex 56 G, ElastoRex S6 G FR, Mule -Hide SA-APP Cap Sheet, Mule -Hide SA-APP Cap
Adhesive -set the roof system
180
Sheet(FRI, Polyflex G, Polynex G IN, Polyflex SA P or Polyflex SA P FR
Mechanically attached
UNLIMITED
5.10 Tile Slippage Limitations: When loading roof tiles on the underlayment in direct -deck the roof assemblies, the maximum roof
slope shall be as follows. These slope limitations can on IV be exceeded by ndna l,.ne.,. d:.,.,,.
TAaIE 4: THE SLIPPAGE LJMRATiONS FOR DIaECf-DECKMLE PUTAL ATI0N5
Urlderlaymem
Tile Profile
Staging Medged
Maximum Staging Slope
Elartoflex 56 G or S6 G FR
Flat or Lugged
6-tile stack (4 over 2)
Prohibited without battens
HydraGuard Tile Pro
Flat or Lugged
4tile stack (4 over 2)
7:12
POlyflex G or G FR
Flat or Lugged
6-tile stack (4 over 2)
4:12
Polyflex SA P or SA P FR
Flat or Lugged
6-tile stack (4 over 2)
4:12
Polystick MTS Plus
Flat
6-tile stack (4 over 2)
5:12
Lugged
6-tle stack (4 over 2)
4:12
Polystick TU Max
Flat
6-tile stack (4 over 2) or 10-tlie stack
7:12
Lugged
&tile stack (4 Over 2)
7:12
Lugged
10-tile stack
6:12
Polystick TU P
Flat or Lugged
6-tile stack (4 over 2)
7:12
Polystick TU Plus
Flat or Lugged
6-tile stack (4 over 2)
7;12
Flat or Lugged
10-tile stack
6:12
Polystick XFR
Flat or Lugged
Prohibited without battens
Prohibited without battens
NEMO ETC. U.C. Evaluallan R.Pon P1206o.02.09-R27
CPrdQmfe o/Authonosup g32455 P EDITION (2020) PIC NON-HVHS EVALUATION 0.5259-R31
Polyglass Roof Underlayments Revision 27: 09/30/2020
Page 15 or 17
6. INSTALLATION; ®NEMO j etc.
6.1 Polyglass Roof Underlayments shall be installed In accordance with Polyglass published installation instructions subject to the
Limitations set forth in Section 5 herein and the specifics noted below.
6.2 Re -fasten any loose decking panels, and check for protruding nail heads. Sweep the substrate thoroughly to remove any dust
and debris prior to application, and prime the substrate (if applicable).
6.3 Elastobase, Elastobase P or Mule -Hide Nail Base:
6.3.1 Non -Tile Applications:
Shall be installed in compliance with requirements for an approved mechanically attached underlayment (ASTM D226, Type
II) in FBC Table 1507.1.1.1 or FBC Residential Table R905.1.1.1 for the type of prepared roof covering to be installed, and the
manufacturer's installation instructions. FBC requirements take precedence over the manufacturer's Installation instructions.
Elastobase, Elastobase P or Mule -Hide Nail Base may be covered with a layer of Polystick IR-Xe, Polystick MTS Plus, Polystick
MU-X, Polystick TU Max, Polystick TU P, Polystick TU Plus, Polystick XFR, Polyflex SAP, Polyflex SA P FR, Mule -Hide SA-APP Cap
Sheet or SA-APP Cap Sheet (FR), self -adhered, Elastoflex S6 G or Elastoflex S6 G FR in hot asphalt or PolyRex G or Polyflex G
FR, torch applied. Roof cover limitations are those are those associated with the top -layer underlayment, asset forth in Table
1.
6.3.2 Tile Applications
6.3.2.1 Elastobase (poly -film top), Elastobase P (poly -film top) and Mule -Hide Nail Base are limited to use as a mechanically attached
base sheet in the "TWO-PLY SYSTEM" from FRSA/TRI Florida High Wind Concrete and Clay Roof Tile Installation Manual, Sixth
Edition, followed by Polystick MTS Plus, Polystick TU Max, Polystick TU P, Polystick TU Plus, Polystick XFR, Polyflex SAP, Polyflex
SA P FR, Mule -Hide SA-APP Cap Sheet or SA-APP Cap Sheet (FR), self -adhered or Polyflex G or Polyflex G Fit, torch -applied. Tile
roof installation method is limited by the selected Cap Sheet, as set forth in Table 1. Refer to Section 5.8.3.2 herein for
attachment requirements.
6.3.2.2 Elastobase (sanded -top) and Elastobase P(sanded-top)e are limited to use as a mechanically attached base sheet in the "TWO-
PLY SYSTEM" from FRSAjTRI Florida High Wind Concrete and Gay Roof Tile Installation Manual, Sigh Edition, followed by
Elastoflex S6 G, Elastoflex S6 G FR or an FBC Approved Mineral Surfaced Cap Sheet (ASTM D6380), asphalt -applied or Polyflex
G or Polyflex G FR, torch -applied. Tile roof installation method is limited by the selected Cap Sheet, as set forth in Table 1.
• When Elastobase (sanded -top) or Elastobase P (sanded -top) is followed by asphalt -applied Elastoflex 56 G, Elastoflex S6
G FR or FBC Approved Mineral Surfaced Cap Sheet (ASTM D6380), refer to FRSA/TRI, Sixth Edition, Appendix A, Table 1
or Section 5.8.3.2 herein for attachment requirements.
• When Elastobase (sanded -top) or Elastobase P(sanded-top) is followed by torch -applied Polyflex G or Polyflex G FR, refer
to Section 5.8.3.2 herein for attachment requirements.
6.4 HydraGuard Dual Pro, HydraGuard Tile Pro, Mule -Hide SA-APP Cap Sheet, Mule -Hide SA-APP Cap Sheet (FR), Polyflex SA P,
Polyflex SA P FR, Polystick IR-Xe, Polystick RM Plus, Polystick MU-X, Polystick TU Max, Polystick TU P, Polystick TU Plus or
Polystick XFR:
6.4.1 Generale
All seal -lap seams (selvage laps) must be firmly rolled with a
in accordance with Polyglass requirements to ensure full
contact and adhesion. For HydraGuard Dual Pro and
HydraGuard Tile Pro, align the edge of the top sheet to the
end of the glue pattern (the sheet will overlap the fabric).
View Of Ovelap Seam of HydraGuard Dual Pro and HydraGuard Tlie Pro
NEMO ETC, uc.m Evaluation Report PI2060A1.09-R27
Cettifimteo)PurMnffiion #32A55 7P'EDITION 12010)FBC NON-HVHZ EVALUATION FL5259-131
Polyglass Roof Undedaymenta Revision 27: M/30/2010
Page 16 of 17
6.4.2 Non -Tile Applications: *Nwojetc.
Shall be Installed in compliance with requirements for an approved self -adhering underlayment (ASTM D3970) in FBC
1507.1.1.1 or 1507.1.1.3 or FBC Residential R905.1.1.1 or R905.1.1.3 for the type of prepared roof covering to be installed,
and the manufacturer's Installation instructions.
When installed over a mechanically attached base sheet of FBC Approved ASTM D226, Type II felt, Elastobase, Elastobase P or
Mule -Hide Nail Base, the base sheet shall be fastened in accordance with FBC 1507.1.1 or R905.1.1.
6.4.3 Tile Applications (excludes Hdrat and DUal Pm, Polystick IR_Xand P lyst kMUXI
Shall be installed in compliance with the requirements for Self -Adhered Membrane set forth in FRSA/TRI Florida High Wind
Concrete and day Roof Tile Installation Manual, Sixth Edition and the manufacturer's installation instructions.
Refer to Section 5.8.3 herein for attachment limitations.
Refer to Table 4 herein for tile staging limitations.
6.4.4 Multi -Ply Underlavm tSystems:
Polystick MTS Plus or Polystick XFR followed by HydraGuard Tile Pro, PolyneXSA P, Polystick MTS Plus, Polystick MU-X, Polystick
TU Max, Polystick TU P, Polystick TU Plus or Polystick XFR is allowable for use under mechanically attached prepared roof
systems. Limits of use are those associated with the top -layer material. This is not a requirement, but is allowable if a 2-ply
underlayment system is desired.
Polystick MTS Plus followed by HydraGuard Tile Pro, Polyflex SA P, Polystick TU Max, Polystick TU P or Polystick TU Plus is
allowable for use under adhesive -set tile systems. Limits of use are those associated with the top -layer material. Thisisnota
requirement, but is allowable if a 2-ply underlayment system is desired.
6.5 ElastoRex 56 G or Elastoflex 56 G FR:
6.5.1 Shall be installed incompliance with requirements as an alternate to the "Hot Asphalt Applied Cap Sheet" in the 'Two Ply
System" in the FRSA/7RI Florida High Wind Concrete and Clay Roof Tile Installation Manual, Sixth Edition, and the
manufacturer's installation instructions.
Refer to Section 5.8.2 and 5.8.3 herein for attachment limitations.
Refer to Table 4 herein for the staging limitations.
6.6 Polyflex G or Polyflex G FR:
6.6.1 Shall be installed in compliance with requirements as an alternate to the "Heat Applied Cap Sheet" in the Two Ply System" in
the FRSA/TRI Florida High Wind Concrete and Clay Roof Tile Installation Manual, Sixth Edition, and the manufacturer's
installation instructions.
Refer to Section 5.8.3 herein for attachment limitations.
Refer to Table 4 herein for tile staging limitations.
required by the Building Official or Authority Having Jurisdiction to properly evaluate the installation of this
Contact the named CIA entity for manufacturing facilities covered by F.A.C. Rule 61G20-3 CIA requirements. Refer to
4 herein for products and production locations having met codified material standards.
UL LLC— QUA9625; (414) 248-6409;
END OF EVALUATION REPORT -
NEMO ETC, I.I.C. Evaluation Report P32060.02.U9-R27
Cem7,wocvAulhwdatkar3Nss 7" EDmON(2020)FBC NON-HVHZ EVALUATION FL5259-R31
Poinlass Roof Underleyments Revislon 27:09/W/2020
Page 17 of 17