Product Approval Menu > Product or Application Search > Application List > Application Detail
FL # FL10626-R20
Application Type Revision
Code Version 2020
Application Status Approved
Comments
Archived
Product Manufacturer GAF
Address/Phone/Email 1 Campus Drive
Parisppany, NJ 07054
(800)766-3411
mstieh@gaf.com
Authorized Signature Robert Nieminen
Ireith@nemoetc,com
Technical Representative William Broussard
Address/Phone/Email 1 Campus Drive
Parsippany, NJ 07054
(800) 766-3411
TechnicaIQuestionsGAF@gaf.com
Quality Assurance Representative
Address/Phone/Email
Category Roofing
Subcategory Underlayments
Compliance Method Evaluation Report from a Florida Registered Architect or a Licensed Florida
Professional Engineer
Evaluation Report - Hardcopy Received
Florida Engineer or Architect Name who developed the Robert Nieminen
Evaluation Report
Florida License PE-59166
Quality Assurance Entity UL LLC
Quality Assurance Contract Expiration Date 12/17/2021
Validated By John W. Knezevich, PE
Certificate of Independence
Referenced Standard and Year (of Standard)
Validation Checklist - Hardcopy Received
FL10626 R20 COI 2021 01 COI NIEMINEN pdf
Standard
ASTM D1970
ASTM D4533
ASTM D4798
ASTM D4869
ASTM D5035
ASTM D6164
ASTM D6757
FM 4474
Year
2015
2015
2011
2016
2011
2011
2016
2011
Equivalence of Product Standards
Certified By
Sections from the Code
Product Approval Method
Date Submitted
Date Validated
Date Pending FBC Approval
Date Approved
Date Revised
of Prod
Method 1 Option D
02/01/2021
02/07/2021
02/09/2021
04/13/2021
04/14/2021
I FL # Model, Number or Name j Description
10626.1 GAF Roof Underlayments Roofing Underlayments for use in sloped roof systems
Limits of Use
Approved for use in HVHZ: No
Approved for use outside HVHZ: Yes
Impact Resistant: N/A
Design Pressure: +N/A/-442.5
Other: 1.) The design pressure noted in this
application relates to one particular
underlayment system. Refer to ER Section 5.8.3
for details. 2.) Refer to ER Section 5 for other
Limits of Use.
Installation Instructions
FL10626 R20 II 2021 01 28 FINAL ER GAF UNDERLAYMENTS FL10626-
R20.pdf
Verified By: Robert Niemien 59166
Created by Independent Third Party: Yes
Evaluation Reports
FL10626 R20 AE 2021 01 28 FINAL ER GAF UNDERLAYMENTS FL10626-
R20.pdf
Created by Independent Third Party: Yes
Contact Us :: 2601 Blair Stone Road, Tallahassee FL 32399 Phone: 850-487-1824
The State of Florida is an AA/EEO employer. Copyright 2007-2013 State of Florida :: Privacy Statement :: Accessibility Statement :: Refund Statement
Under Florida law, email addresses are public records. If you do not want your e-mail address released in response to a public -records request, do not send electronic
mail to this entity. Instead, contact the office by phone or by traditional mail. If you have any questions, please contact 850.487.1395. *Pursuant to Section 455.275(1),
Florida Statutes, effective October 1, 2012, licensees licensed under Chapter 455, F.S. must provide the Department with an email address if they have one. The emails
provided may be used for official communication with the licensee. However email addresses are public record. If yo
provide the Department with an email address which can be made available to the public. To determine if you are a liu do not wish to supply a personal address, please
censee under Chapter 455, F.S., please click here .
Product Approval Accepts:
PW cheek ,
Credit Card
Safe
NS
NEMO I etc.
Certificate of Authorization #32455
353 Christian Street, Unit #13
Oxford, CT 06478
(203)262-9245
ENGINEER EVALUATE TEST CONSULT
EVALUATION .O.
GAF Evaluation Report 01506.04.08-1120
1Campus Drive FL10626-1120
Parsippany, NJ 07054 Date of Issuance: 04/25/2008
(800) 766-3411 Revision 20: 01/28/2021
SCOPE:
This Evaluation Report is issued under Rule 61G20-3 and the applicable rules and regulations governing the use of
construction materials in the State of Florida. The documentation submitted has been reviewed by Robert Nieminen,
P.E. for use of the product under the Florida Building Code and Florida Building Code, Residential Volume. The products
described herein have been evaluated for compliance with the 711 Edition (2020) Florida Building Code sections noted
herein.
f DESCRIPTION: GAF Roof Underlayments
LABELING: Labeling shall be in accordance with the requirements of the Accredited Quality Assurance Agency noted
herein and FBC 1507.1.1.
CONTINUED COMPLIANCE: This Evaluation Report is valid until such time as the named product(s) changes, the referenced
Quality Assurance or production facility location(s) changes, or Code provisions that relate to the product(s) change.
Acceptance of our Evaluation Reports by the named client constitutes agreement to notify NEMO ETC, LLC of any
changes to the product(s), the Quality Assurance or the production facility location(s). NEIVIO ETC, LLC requires a
complete review of its Evaluation Report relative to updated Code requirements with each Code Cycle.
ADVERTISEMENT: The Florida Product Approval Number (FL#) preceded by the words "NEMO I etc. Evaluated" may be
displayed in advertising literature. If any portion of the Evaluation Report is displayed, then it shall be done in its
entirety.
INSPECTION: Upon request, a copy of this entire Evaluation Report shall be provided to the user by the manufacturer or
its distributors and shall be available for inspection at the job site at the request of the Building Official.
This Evaluation Report consists of pages 1 through 8.
Prepared by:
Robert J.M. Nieminen, P.E.
Florida Registration No. 59166, Florida DCA ANE1983
The facsimile seal appearing was authorized by Robert
Nieminen, P.E. on 01/28/2021. This does not serve as an
electronicall si ned d
CERTIFICATION OF INDEPENDENCE: y g ocument.
I. NEW ETC, LLC does not have, nor does it intend to acquire or will it acquire, a financial interest in any company manufacturing or
distributing products it evaluates.
2. NEMO ETC, LLC is not owned, operated or controlled by any company manufacturing or distributing products it evaluates.
3. Robert Nieminen, P.E. does not have nor will acquire, a financial interest in any company manufacturing or distributing products for
which the evaluation reports are being issued.
4. Robert Nieminen, P.E. does not have, nor will acquire, a financial interest in any other entity involved in the approval process of the
product.
5. This is a building code evaluation. Neither NEMO ETC, LLC nor Robert Nieminen, P.E. are, in any way, the Designer of Record for any
project on which this Evaluation Report, or previous versions thereof, is/was used for permitting or design guidance unless retained
specifically for that purpose.
©2019 NEMO ETC, LLC
(NNEMOJetc.
ROOFING COMPONENT EVALUATION:
SCOPE:1.
Product Category:
Roofing
Sub -Category:
Underlayment
Compliance Statement: GAF
Roof Underlayments, as produced by GAF, have demonstrated compliance with the
following sections of the 7t' Edition (2020) Florida Building Code through testing in accordance
with the following
Standards. Compliance is subject
to the Installation Requirements and Limitations / Conditions of Use set forth
herein.
2. STANDARDS.
Section
Pro a
Standard
Year
1504.3.1
Wind resistance
FM 4474
2011
1507.1.1, 1507.2.4, 1507.2.9.2 /
Material standard
ASTM D1970
2015
R905.1.1, R905.2.8.2
1507.1.1.1(2&3, Exception),
Tear Strength
ASTM D4533
2015
1507.1.1.1(5) / R905.1.1.1(2&3,
Exception), R905.1.1.1(5)
1507.1.1.1(2&3, Exception),
Tensile strength
ASTM D5035
2011
1507.1.1.1(5) / R905.1.1.1(2&3,
Exception), R905.1.1.1(5)
1507.1.1.1(5) / R905.1.1.1(5)
Liquid water transmission
ASTM D4869
2016
1507.1.1 / R905.1.1
Material standard
ASTM D6757
2016
1507.3.3, R905.3.3
Material standard
FRSA/TRI, Sixth Edition
2018
1507.11.2
Material standard
ASTM D6164
2011
TAS 110
Accelerated Weathering
ASTM D4798
2011
3. REFERENCES'
Entity
Examination
Reference
Date
ERD (TST 6049)
ASTM D1623 & FRSA/TRI (Slippage)
G34150.08.11
11/14/2011
ERD (TST 6049)
ASTM D6164 (GA)
G40630.01.14-26
01/07/2014
ERD (TST 6049)
ASTM D6164 (GA)
G46160.09.14-3A
09/09/2014
ERD (TST 6049)
ASTM D1970 (GA)
GAF-SC13285.03.17-3
03/01/2017
ERD (TST 6049)
ASTM D1970 (GA)
GAF-SC13285.03.17-4
03/01/2017
ERD (TST 6049)
ASTM D1970 (GA)
GAF-SC13285.03.17-1
03/08/2017
ERD (TST6049)
ASTM D1970 (IN)
GAF-SC16440.12.17
12/31/2017
Intertek(TST 1558)
ASTM D4869 (Dadra, India)
F8549.02-106-18
11/08/2016
NEMO (TST 6049)
Physical Properties (ON)
4q-GAF-I9-SSMBB-03.A
05/13/2019
PRI (TST 5878)
ASTM D1970 (IN)
GAF-324-02-01
11/30/2011
PRI (TST 5878)
ASTM D226 (OK)
GAF-339-02-01
03/13/2012
PRI (TST 5878)
ASTM D4798 (NC)
GAF-349-02-01
07/03/2012
PRI (TST 5878)
Wind Uplift
GAF-434-02-01
09/16/2013
PRI (TST 5878)
Wind Uplift
GAF-434-02-03
09/16/2013
PRI (TST 5878)
Wind Uplift
GAF-434-02-04
09/16/2013
PRI (TST 5878)
ASTM D4533 (various)
GAF-818-02-01
12/05/2017
PRI (TST 5878)
ASTM D1970(AL)
MSA-047-02-01
04/11/2018
PRI (TST 5878)
ASTM D4533 (LA)
GAF-826-02-01
06/4/2018
PRI (TST 5878)
ASTM D4533 (Dadra, India)
GAF-847-02-01
06/4/2018
PRI (TST 5878)
ASTM D4533 (Dadra, India)
GAF-914-02-01
04/10/2019
PRI (TST 5878)
ASTM D4533, D5035 (VA)
376T0012
07/15/2019
PRI (TST 5878)
ASTM D4533 (Umerkui Kilvani, India)
376T0018
07/31/2019
PRI (TST 5878)
ASTM D4533 (Parzai, India)
376T0018
07/31/2019
PRI (TST 5878)
ASTM D1970 (AR)
376T0032
10/22/2019
PRI (TST 5878)
ASTM D5035 (various)
376TO103
09/11/2020
UL(TST 1740)
ASTM D6757(TX)
02NK22569
06/04/2002
NEMO ETC, LLC Evaluation Report 01506.04.08-1120
Certificate ojAuthorization#32455 1T"EDITION (2020) FBC NON-HVHZ EVALUATION F1.10626-1120
GAF Roof Underlayments Revision 20: 01/28/2021
Page 2 of 8
4.
4.1
4.2
4.3
4.4
4.5
4.6
4.7
4.8
4.9
4.10
4.11
En__. tity
Examination
UL (TST 1740)
ASTM D6757 (NC)
NEMO ETC
Traceability
UL, LLC (QUA 9625)
Quality Control
UL, LLC (QUA 9625)
Quality Control
UL, LLC (QUA 9625)
Quality Control
tONEMO I etc.
Reference Date
10NK11990 05/18/2011
FBC Cross -Listing 04/22/2020
Service Confirmation 09/29/2020
Service Confirmation (AL) 05/04/2020
Florida BCIS Current
PRODUCTDESCRIPTION'
Product
Material Standard
Plant(s)
Liberty'm SBS Self -Adhering Base/Ply
Mt. Vernon, IN
Sheet
ASTM D1970
Savannah, GA
StormGuard® Film Surfaced Leak Barrier
ASTM D1970
Mt. Vernon, IN
Savannah, GA
Arkadelphia, AR
WeatherWatch® Mineral Surfaced Leak
Mt. Vernon, IN
Barrier
ASTM D1970
Savannah, GA
Tuscaloosa, AL
Deck-Armor"Premium Breathable Roof
1507.1.1.1(2&3, Exception) J
Deck Protection
R905.1.1.1(2&3, Exception)
Dadra, India
FeltBuster® High -Traction Synthetic
1507.1.1.1(2&3, Exception),
Dadra, India
Roofing Felt
1507.1.1.1(5) / R905.1.1.1(2&3,
Richmond, VA
Exception), R905.1.1.1(5)
Spartanburg, SC
Shingle -Mate® Roof Deck Protection
ASTM D226, Type II (Table 1)
Pryor, OK
StormSafell Anchor Sheet
1507.1.1.1(2&3, Exception) /
North Bay, ON
R905.1.1.1(2&3, Exception)
Tiger PawT"" Roof Deck Protection
1507.1.1.1(2&3, Exception) /
Dadra, India
R905.1.1.1(2&3, Exception)
Parzai, India
Umerkui Kilvani, India
VersaShield® Fire -Resistant Roof Deck
Protection
ASTM D6757
Conover, NC
Ruberoid® Mop Granule
ASTM D6164
Savannah, GA
FRSA/TRI 09-18
Ruberoid® Mop Granule FR
ASTM D6164
Savannah, GA
FRSA/TRI 09-18
LIMITATIONS:S.
5.1 This is a building code evaluation. Neither NEMO ETC, LLC nor Robert Nieminen, P.E. are, in any way, the Designer
of Record for any project on which this Evaluation Report, or previous versions thereof, is/was used for permitting
or design guidance unless retained specifically for that purpose.
5.2 This Evaluation Report is not for use in FBC High Velocity Hurricane Zone jurisdictions (i.e., Broward and Miami -
Dade Counties).
5.3 This Evaluation Report pertains to above -deck roof components. Roof decks and structural members shall be in
accordance with FBC requirements to the satisfaction of the Authority Having Jurisdiction.
5.4 This Evaluation Report does not include evaluation of fire classification. Refer to FBC 1505 for requirements and
limitations regarding roof assembly fire classification. Refer to FBC 2603 for requirements and limitations
concerning the use of foam plastic insulation.
NEMO ETC, LLC Evaluation Report 01506.04.08-R20
Certificate of Authorization #32455 77H EDITION (2020) FBC NON-HVHZ EVALUATION FL10626-R20
GAF Roof Underlayments Revision 20: 01/28/2021
Page 3 of 8
ONEMOletc.
5.5 GAF Roof Underlayments may be used with any prepared roof cover where the product is specifically referenced
within FBC approval documents. If not listed, a request may be made to the Authority Having Jurisdiction for
approval based on this evaluation combined with supporting data for the prepared roof covering.
5.6 Allowable Roof Covers:
TABLE 1: ROOF COVER OPTIONS
FBC Section:
1507.2
1507.3
1507.4 and 1507.5
1507.7
1507.8 and 1507.9
Clay and Concrete Tile
Metal
Slate or
Wood
Underlayment
Asphalt
Shingles
Slate -Type
Mechanical
Adhesive
Panels
Shingles
Shingles
Shakes
Shingles
g
Yes
Yes
Liberty- SBS Self -Adhering
Yes
No
No
No
No
No
(joint strips,
(joint strips,
Base/Ply Sheet
1507.1.1.3/
1507.1.1.3/
R905.1.1.3)
R905.1.1.3)
Yes
Yes
StormGuard® Film Surfaced Leak
Yes
No
No
Yes
Yes
Yes
(Joint strips,
(joint strips,
Barrier
1507.1.1.3 /
1507.1.1.3 /
R905.1.1.3)
R905.1.1.3)
Yes
Yes
WeatherWatch® Mineral Surfaced
Yes
No
No
No
No
No
Leak Barrier
1,507.1.13/
1,507.1.13/
R905.1.1.3)
R905.1.1.3)
Deck -Armor'" Premium Breathable
Yes
No
No
Yes
Yes
Yes
No
No
Roof Deck Protection
FeItBuster® High -Traction
Yes
No
No
No
No
No
No
No
Synthetic Roofing Felt
Shingle -Mate" Roof Deck
Yes
No
No
No
No
No
No
No
Protection
Tiger Paw'" Roof Deck Protection
Yes
No
No
Yes
Yes
Yes
No
No
VersaShield® Fire -Resistant Roof
Yes
No
No
No
No
No
No
No
Deck Protection
Yes
Yes
Ruberoid® MopGranule
No
(Cap Sheet in
(Cap Sheet in
No
No
NO
NO
NO
2-ply system)
2-ply system)
See 5.6.1
Yes
Yes
Ruberoid® MopGranule FR
No
(Cap Sheet in
(Cap Sheet in
No
No
No
No
No
2-ply system)
2-ply system)
See 5.6.1
5.6.1 Adhesive -set is limited to use of following underlayment / tile -adhesive combinations.
TABLE 1A: ALLOWABLE UNDERLAYMENT / TILE -ADHESIVE COMBINATIONS'
Underlayment
Adhesive
Florida Product Approval
Ruberoid® Mop Granule; Ruberoid® Mop Granule FIR
Dupont "Tile BondT' Roof Tile Adhesive"
FL22525
I Refer to Tile Manufacturer's or Adhesive Manufacturer's Florida Product Approval for Overturning Moment Resistance Performance.
NEMO ETC, LLC Evaluation Report 01506.04.08-R20
Certificate of Authorization #32455 7T" EDITION (2020) FBC NON-HVHZ EVALUATION FL10626-R20
GAF Roof Underlayments Revision 20: 01/28/2021
Page 4 of 8
ONEMOletc.
5.7 Allowable Substrates:
TABLE 2: SUBSTRATE OPTIONS FOR ADHERED UNDERLAYMENTS
Underlayment
Application
Primer
Substrates
Liberty'" SBS Self -Adhering Base/Ply Sheet
self -adhering
(Optional)
ASTM D41
plywood
StormGuard® Film Surfaced Leak Barrier
Weather Watch® Mineral Surfaced Leak Barrier
Liberty"" SBS Self -Adhering Base/Ply Sheet
self -adhering
None
ASTM D226 felt, Type 11
StormGuard® Film Surfaced Leak Barrier
Weather Watch® Mineral Surfaced Leak Barrier
Liberty'" SBS Self -Adhering Base/Ply Sheet
self -adhering
ASTM D41
metal (flashing metal, valley metal,
etc.)
StormGuard® Film Surfaced Leak Barrier
Weather Watch® Mineral Surfaced Leak Barrier
Ruberoid® Mop Granule
hot asphalt
ASTM D41
structural concrete
Ruberoid® Mop Granule FR
Ruberoid® Mop Granule
hot asphalt
None
GAFGLAS® #80 Ultimall Base Sheet
or Ruberoid® 20 Smooth
®
Ruberoid Mop Granule FR
5.8 Attachment Limitations:
5.8.1 For use under mechanically attached NON -TILE prepared roof coverings, attachment shall be in accordance with
the manufacturer's installation instructions, but —for mechanically attached underlayments or base sheets - not
less than FBC 1507.1.1 or R905.1.1.
5.8.2 For use under tile roof systems, attachment shall be in accordance with the manufacturer's installation
instructions, but — for mechanically attached base sheets - not less than:
• FRSA/TRI Florida High Wind Concrete and Clay Roof Tile Installation Manual, Sixth Edition, Appendix A,
Table 1(for Two -Ply Asphalt Applied Hot Mop Underlayment)
or
• Section 5.8.3 herein (for other underlayment systems).
5.8.3 Wind Resistance for Underlayment Systems in Tile Roof Applications:
The following wind uplift limitations apply to underlayment systems that are not prescriptive in the FRSA/TRI
Florida High Wind Concrete and Clay Roof Tile Installation Manual, Sixth Edition. The Maximum Design Pressure
is the result of testing for wind load resistance based on allowable wind loads, and reflects the ultimate passing
pressure divided by 2 (the 2 to 1 margin of safety per FBC 1504.9 has already been applied).
5.8.3.1 Direct -to -Deck:
The maximum design pressure for the selected assembly shall meet or exceed that required under FRSA/TRI
Florida High Wind Concrete and Clay Roof Tile Installation Manual, Sixth Edition, Appendix A, Table 1A or the
critical (highest) design pressure determined in accordance with FBC 1609 or FBC Residential Chapter 3.
#1 Maximum Design Pressure = -442.5 psf.
Deck: Min. 2,500 psi structural concrete to meet project requirements to satisfaction of Authority Having
Jurisdiction
Base Sheet: GAFGLAS #75 Base Sheet, Tri-Ply #75 Base Sheet, GAFGLAS #80 Ultima Base Sheet, GAFGLAS Ply 4,
Tri-Ply Ply 4 or GAFGLAS Flex Ply 6 applied in full mopping of ASTM D312, Type IV hot asphalt at 20
to 25 Ibs/square.
Cap Sheet: Ruberoid® Mop Granule or Ruberoid® Mop Granule FR applied in full mopping of ASTM D312, Type
IV hot asphalt at 20 to 25 Ibs/square.
MEMO ETC, LLC Evaluation Report 01506.04.08-R20
Certificate of Authorization #32455 7'" EDITION (2020) FBC NON-HVHZ EVALUATION FL10626-R20
GAF Roof Underlayments Revision 20: 01/28/2021
Page 5 of 8
(NNEMOJetc.
5.8.3.2 Mechanically -Attached Base Sheet:
The maximum design pressure for the selected assembly shall meet or exceed that required under FRSA/TRI
Florida High Wind Concrete and Clay Roof Tile Installation Manual, Sixth Edition, Appendix A, Table 1A or the
critical (highest) design pressure determined in accordance with FBC 1609 or FBC Residential Chapter 3.
Alternatively, the maximum design pressure for the selected assembly shall meet or exceed at least the Zone 1
design pressure determined in accordance with FBC 1609 or FBC Residential Chapter 3. Elevated pressure zones
shall employ an attachment density designed by a qualified design professional to resist the elevated pressure
criteria. Commonly used methods are ANSI/SPRI WD1, FM Loss Prevention Data Sheet 1-29, Roofing Application
Standard RAS 117 and Roofing Application Standard RAS 137. Assemblies marked with an asterisk* carry the
limitations set forth in Section 2.2.10.1 of FM Loss Prevention Data Sheet 1-29 (February 2020) for
enhancements.
#2 Maximum Design Pressure = -45 psf.
Deck: Min. 19/32-inch plywood to meet project requirements to satisfaction of Authority Having
Jurisdiction.
Base Sheet: GAFGLAS® #80 UltimaT' Base Sheet or Ruberoid® 20 Smooth mechanically attached with 12 ga.,
min. 1.25-inch long ring shank nails through 32 ga., 1-5/8-inch diameter tin caps spaced 9-inch D.C.
at the min. 4-inch wide side laps and 9-inch D.C. at two (2), equally spaced, staggered center rows
in the field of the sheet.
Cap Sheet: Ruberoid® Mop Granule or Ruberoid® Mop Granule FR applied in full mopping of ASTM D312, Type
IV hot asphalt at 20 to 25 Ibs/square.
#3 Maximum Design Pressure = -75 psf.
Deck: Min. 19/32-inch plywood to meet project requirements to satisfaction of Authority Having
Jurisdiction.
Base Sheet: GAFGLAS® #80 UltimaT' Base Sheet or Ruberoid® 20 Smooth mechanically attached with 12 ga.,
min. 1.25-inch long ring shank nails through 32 ga., 1-5/8-inch diameter tin caps spaced 8-inch o.c.
at the min. 4-inch wide side laps and 8-inch o.c. at three (3), equally spaced, staggered center rows
in the field of the sheet.
Cap Sheet: Ruberoid® Mop Granule or Ruberoid® Mop Granule FR applied in full mopping of ASTM D312, Type
IV hot asphalt at 20 to 25 Ibs/square.
#4 Maximum Design Pressure = -97.5 psf.
Deck: Min. 19/32-inch plywood to meet project requirements to satisfaction of Authority Having
Jurisdiction.
Base Sheet: GAFGLAS® #80 UltimaTm Base Sheet or Ruberoid® 20 Smooth mechanically attached with 11 ga.,
min. 1.25-inch long ring shank nails through 32 ga., 1-5/8-inch diameter tin caps spaced 4-inch D.C.
at the min. 2-inch wide side laps and 4-inch o.c. at four (4), equally spaced center rows in the field
of the sheet.
Cap Sheet: Ruberoid® Mop Granule or Ruberoid® Mop Granule FR applied in full mopping of ASTM D312, Type
IV hot asphalt at 20 to 25 Ibs/square.
NEMO ETC, LLC Evaluation Report 01506.04.08-1120
Certificate of Authorization #32455 7T" EDITION (2020) FBC NON-HVHZ EVALUATION FL10626-R20
GAF Roof Underlayments Revision 20: 01/28/2021
Page 6 of 8
ONEMOJetc.
5.9 Exposure Limitations:
TABLE 3: EXPOSURE LIMITATIONS
Underlayment
Prepared Roof Cover
Maximum
Exposure
Installation Type
(days)
Deck -Armor TM Premium Breathable Roof Deck Protection, FeltBuster® High -Traction
Synthetic Roofing Felt, Shingle -Mate® Roof Deck Protection, StormSafeTm Anchor
Sheet, Tiger Pawl Roof Deck Protection, VersaShield® Fire -Resistant Roof Deck
Mechanically attached
30
Protection, LibertyTM' SBS Self -Adhering Base/Ply Sheet, StormGuard® Film Surfaced
Leak Barrier and WeatherWatch® Mineral Surfaced Leak Barrier
Ruberoid® Mop Granule and Ruberoid® Mop Granule FIRAdhesive
set the roof system
180
Mechanically attached
UNLIMITED
5.10 Tile Slippage Limitations: When loading roof tiles on the underlayment in direct -deck tile roof assemblies, the
maximum roof slope shall be as follows. These slope limitations can only be exceeded by using battens during
loading of the roof tiles.
TABLE 4: TILE SLIPPAGE LIMITATIONS FOR DIRECT -DECK TILE INSTALLATIONS
Underlayment
Tile Profile
Staging Method
Maximum Staging Slope
Ruberoid® Mop Granule
Flat
Max. 10-tile stack
4:12
Flat
Max. 6-tile stack (4 over 2)
5:12
Lugged
Max. 10-tile stack
5:12
Ruberoid® Mop Granule FR
Flat or Lugged
Max. 6-tile stack (4 over 2)
5:12
Lugged
Max. 10-tile stack
4:12
INSTALLATION:
6.1 GAF Roof Underlayments shall be installed in accordance with GAF published installation instructions subject to
the Limitations set forth in Section 5 herein and the specifics noted below.
6.2 Re -fasten any loose decking panels, and check for protruding nail heads. Sweep the substrate thoroughly to
remove any dust and debris prior to application and prime the substrate (if applicable).
6.3 Deck-Armor"I Premium Breathable Roof Deck Protection or Tiger Paw'"" Roof Deck Protection:
6.3.1 Shall be installed in compliance with requirements for a synthetic underlayment in FBC 1507.1.1.1(2, Exception)
or 1507.1.1.1(3, Exception) or FBC Residential R905.1.1.1(2, Exception) or R905.1.1.1(3, Exception) for the type
of prepared roof covering to be installed, and the manufacturer's installation instructions. FBC requirements take
precedence over the manufacturer's installation instructions.
6.4 FeltBuster" High -Traction Synthetic Roofing Felt:
6.4.1 Shall be installed in compliance with requirements for a synthetic underlayment in FBC 1507.1.1.1(2, Exception),
1507.1.1.1(3, Exception) or 1507.1.1.1(5) or FBC Residential R905.1.1.1(2, Exception), R905.1.1.1(3, Exception)
or R905.1.1.1(5) for the type of prepared roof covering to be installed, and the manufacturer's installation
instructions. FBC requirements take precedence over the manufacturer's installation instructions.
6.5 1 StormSafe"" Anchor Sheet:
6.5.1 StormSafeT' Anchor Sheet is limited to use as a mechanically attached base layer in 2-ply underlayment systems.
6.5.2 Shall be installed in compliance with requirements for a synthetic underlayment in FBC 1507.1.1.1(2, Exception)
or 1507.1.1.1(3, Exception) or FBC Residential R905.1.1.1(2, Exception) or R905.1.1.1(3, Exception) for the type
of prepared roof covering to be installed, and the manufacturer's installation instructions. FBC requirements take
precedence over the manufacturer's installation instructions.
NEMO ETC, LLC Evaluation Report 01506.04.08-1120
CertifcateofAuthorization#32455 7'"EDITION (2020) FBC NON-HVHZ EVALUATION FL10626-R20
GAF Roof Underlayments Revision 20: 01/28/2021
Page 7 of 8
U(4
MEMO I etc.
6.5.3 One the same day, install LibertyTM SBS Self -Adhering Base/Ply; StormGuard® Film Surfaced Leak Barrier or
WeatherWatch® Mineral Surfaced Leak Barrier over the StormSafeTm Anchor Sheet.
6.6 Shingle -Mate® Roof Deck Protection:
6.6.1 Shall be installed in compliance with requirements for an approved mechanically attached underlayment (ASTM
D226, Type II) in FBC Table 1507.1.1.1 or FBC Residential Table R905.1.1.1 for the type of prepared roof covering
to be installed, and the manufacturer's installation instructions. FBC requirements take precedence over the
manufacturer's installation instructions.
6.7 VersaShield® Fire -Resistant Roof Deck Protection:
6.7.1 Shall be installed in compliance with requirements for an approved mechanically attached underlayment (ASTM
D6757) in FBC Table 1507.1.1.1 or FBC Residential Table R905.1.1.1 for the type of prepared roof covering to be
installed, and the manufacturer's installation instructions. FBC requirements take precedence over the
manufacturer's installation instructions.
6.8 Liberty' SBS Self -Adhering Base/Ply Sheet, StormGuard® Film Surfaced Leak Barrier or WeatherWatch®
Mineral Surfaced Leak Barrier:
w.U.flu UQ M]ldI11=U III wiiiNudnc a wim requirements ror an approved selt-adhering underlayment (ASTM D1970) in
FBC 1507.1.1.1 or 1507.1.1.3 or FBC Residential R905.1.1.1 or R905.1.1.3 for the type of prepared roof covering
to be installed, and the manufacturer's installation instructions.
6.8.2 Back -nailing is required. Back -nailing shall consist of Approved cap nails spaced 18-inch o.c., encapsulated within
min. 4-inch side laps.
6.8.3 When installed over a mechanically attached, FBC Approved ASTM D226 Type II felt, the felt shall be fastened in
accordance with FBC 1507.1.1 or R905.1.1.
6.8.4 Liberty'"" SBS Self -Adhering Base/Ply Sheet, StormGuard" Film Surfaced Leak Barrier or WeatherWatch®
Mineral Surfaced Leak Barrier may be installed as a secondary water barrier using minimum 4-inch wide rolls to
seal plywood deck joints prior to installation of the primary underlayment system.
6.9 Ruberoid® Mop Granule; Ruberoid® Mop Granule FR:
6.9.1 Shall be installed in compliance with requirements as an alternate to the "Hot Asphalt Applied Cap Sheet" in the
"Two Ply System" in the FRSA/TRI Florida High Wind Concrete and Clay Roof Tile Installation Manual, Sixth
Edition, and the manufacturer's installation instructions.
6.9.2 Refer to Sections 5.8.2 and 5.8.3 herein for attachment limitations.
6.9.3 Refer to Table 4 for tile staging limitations.
REQUIREMENTS:7. BUILDING PERMIT
As required by the Building Official or Authority Having Jurisdiction to properly evaluate the installation of this
product.
8. MANUFACTURING PLANTS'
Contact the named QA entity for manufacturing facilities covered by F.A.C. Rule 6111320-3 QA requirements. Refer
to Section 4 herein for products and production locations having met codified material standards.
QUALiTyAssURANCE ENTITY:
UL, LLC. — QUA9625; (414) 248-6409; karen.buchmann@ul.com
- END OF EVALUATION REPORT -
NEIVIO ETC, LLC Evaluation Report 01506.04.08-R20
Certificate of Authorization #32455 fH EDITION (2020) FBC NON-HVHZ EVALUATION FL10626-R20
GAF Roof Underlayments Revision 20: 01/28/2022
Page 8 of 8