HomeMy WebLinkAboutAPPROVED Flame & Spread Index - 6903 revisions
no. date
(1) BLD6. DEPT.COMMENTS 06/0&/21
designed SBD
project mgr. VHV
checked 5BD
date PERMIT_05/26/21
scale 1/4" = 1'-0" N.O.N)
j o b no. 200q 18_5F.mm.21 st
———————————————————————————————————— Digitally signed by
FCO�'i Scott B Disher
'I"x24" I I yP HF.o DN:c=US,
SOFF I T VENT
ARO 11586 V o=Unaffiliated,
I I ............ �.�� ou=A01410C000001
RED.ARG
ARCHITECTPURAL ASPHALT SHINGLES ON 50# FELT j y Z�� 74BCOA11 FDOOOOE4
HOT MOPPED OVER I5# FELT TIN TAGGED TO Iq/32" I I r"i,i hm inee.ee«,o�i<a�ivd[gi d
nd_I'db S-11B.Di-,AiA-1he FC cn=Scott B
(5/8") EXT.GRADE PLYWD.SHEATHING. I I dzge,n°w inthesgxmp°:i yadiyigai
Disher
Primedcopies dg documentarenog
°°,ide,d.i9oedaodseaiedx°d the,i9 Date:2021.06.09
PRE-EN6. WOOD ROOF TRUSS'S 024" 12 I I °gem°=gbe°e P5°a°veie<g,°°i
0/0 TYPICAL W/APPROVED GALV. I I 15:18:38-04'00'
TRU55 ANCHORS EA. END 4 I I
(SEE FRAMING PLAN) ; ; Scott Blakeslee Disher
GALV. MTL. DRIP I I AR-0011586 AA-0003285
ON P.T. IX2 R-50,BLOWN INSULATION I OFF RIDGE
(SEE ENERGY CALCS) i ROOF VENT
SEE ELEV._ . : : : : : • • • • • • I (TYP)
I I
CONT. 2X8 FASCIA .�,Fy I I
HIGH STRENGTH/RIGID GLG. BRO. I I
APPLIED TO UNDERSIDE OF TRU55'S I I
I I
2-16d GM TOE NAIL I I
® EA. TRU55 1'-`I" I I 12 I
FIRE STOP
I 4 I
-1"x24" SOFFIT VENT O.H. CONT. W%5" MA50NRY BOND BEAM I I
(TYP)
(SEE ROOF PLAN) I (SEE BEAM SCHEDULE) I I
I � I
CEMENTITIOUS COATING OVER CONT. METAL POUR STOP I I
HI-RIB P.B.GALV MTL LATHE I I I
SECURED TO TRUSSES. I/2" DRYWALL I I
5/b" GEMENTITIOU5 FIN15H I I
I
OVER W CONC. BLOCK IX2 P.T. FURRING® 24" O/C, W/ INSUL.. I
SEE ENERGY GALL. - TYPICAL I I
I I
I I
VERTICAL STEEL IN I I
GROUTED CELL I I
(SEE FOUNDATION PLAN) I"x4" HOOD NAILER
APPLIED WOOD BASE I I U
I I
z
FIN. FLOOR TO BE IS" MIN. W
I I/2" BLOCK RECESS II ABOVE GROWN OF ROAD MIN. I I
1 I I Q
MONOLITHIC CONCRETE I I
FOOTING(SEE FOOTING I I
FFLAME SPREAD & SMOKE DEVELOPED INDEX -0" T..0.5�AB II 5CHEOULE) 1'-4" TYP.
-a OVERHANG I W
R502A.1 FLAME SPREAD INDEX:
WALL AND CEILING FINISHES SHALL HAVE A FLAME SPREAD INDEX a° III—III— I I I
OF NOT GREATER THAN 200. z w I_III—III—III d,- III—III—I I I
o I I I-1 I I-1 I I; L__-
R502A.2 5MOKE-DEVELOPED INDEX: N `� 1 1=III=III ° °� —° III—III—III — ____ I .
WALL AND GEILIN6 _FINISHES SHALL HAVE A SMOKE-DEVELOPED - ___—°—_ —_m III=III=11� J U
1 I II II I II II I II II I II II I II II I II II I II II I II II I I- ' C M J
INDEX OF NOT GREATER THAN 450. -
INTERIOR WALL 8 CEILING FINISH BY OCCUPANCY: I 1=III—III—III—III—I I I� III
LL 0 �I w
O 5PR D w
EXIT ENCLOSURES,EXIT PAC505EWAYS, TYPICAL WALL SECTION ROOF PLAN w � 0
GORRIDOR56 ROOMS 6 ENCLOSED SPACES: GLA55 G(FLAME SPREAD 76-200)
(SMOKE DEVELOPED 0-450) SCALE: 5/4" = I'-O" SCALE: 1/8" = 1'-�" J J 121!. U)
INTERIOR FLOOR FINISH: MINIMUM CLASS II
U c¢ cn
z co N
CD
ATTIC VENTILATION REQUIREMENTS ` o
0
THE RATIO OF TOTAL NET FREE VENTILATION AREA TO THE AREA OF project
ATTIC CEILING SHOULD NOT BE LE55 THAN I:150
ROOF VENTILATION CALCULATION:
VENTILATION AREA REQUIRED FOR ATTIC,
ATTIC AREA = 2264/150 = 15.Oq 50.FT. OF VENT OR 2,1-15.44 50.I14.
VENTILATION AREA PROVIDED FOR ATTIC: �� I �� ��
SOFFIT VENT = 2,175.44 SQ.IN.
SOFFIT VENT = 7"X24" = 126 SQ.IN. NFA - I7 VENTS PROVIDED
EXTERIOR CEILING NOTE:
CEMENTITIOUS SOFFIT OVER
GABLE END WALL HI-RIB 6ALV. METAL LATHE
TO COMPLY
VAPOR RETARDER NOTE: H/FEY,-R 105.4 Architecture
AT COVERED ENTRY AND
APPLY CLASS II COVERED LANAI (TYP).
VAPOR RETARDER
(0.1 < PERM <-1.0 PERM) Planning
KRAFT-FACED FIBERGLASS
BATTS FOR ZONE II
PER FBC-R102.1 12
---,]4
PRE-ENGINEERED WD.ROOF ARCHITECTURAL ASPHALT
TRUSSES® 24" O/C TYPICAL ROOFING SHINGLES. Suite
Avenue of Champions
Suite 260
Palm Beach Gardens, Florida 33418
Phone 561.202.6990
Fax 561.296.2494
1'-4" archstudiofl.com
NP• EXTERIOR GEILIN6 NOTE:
O.H. CEMENTITIOU5 SOFFIT OVER
O (a
HI-RIB GALV. METAL LATHE
TO COMPLY W/FBG-R 705.4
V - - AT COVERED ENTRY AND drawing
PORCH FOYER °PE
" �; GALLERY `� OWNERS LANAI COVERED LANAI (TYP.).
SUITE OPEN SECTIONS &
ROOF PLAN
0'-0" FIN. FL.5LABAd
_ _ _ _ _ E. _ _ _1 I 1=1 I 1=1 I 1=1 I 1=1 I 1=1 I 1=1 11= _ = = _ _ _ _ _ _ _
IIIIIIIIIIIIIIII IIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIII I11I1I1I —III_ _III1II I11111IIII—III— IIIIIIIIIIIIIIIIIII I1—
—1II 111I-111 111 111 1 I 1 I-11I ' '—' ' ' ' ' ' ' ' ' '—' ' ' —' ' '— —111=111 1I1 1I1 1I1 111=111=111 iI 1- 1I-
-��1=1�1=111=111=1 I 1—���—�
sheet
A-A SECTION A-A A-3
A-3