APPROVED Manual J's - 6903 Salermo Road
Pro S Job: #20011 +� wrightsoft° Project Date: Aug,2020 6903 Salermo Rd By: Florida Eng.Services,Inc. FES, Inc. 34 NW 168TH ST,NORTH MIAMI BEACH,FL 33169 Phone:305-653-0212 Fax:305-653-0232 License:EB0003628 Project • • For: SINGLE FAMILY HOME,(Owner:21ST STREET,LLC) P`ORcEm3FOm No.43414 `= DigRally,ignad by Alb rcS.Sh°b PE43414 STATE OF :mac; oN:c US,U--FI°dda,I=North %9�`•.,F- 'tV Miami Beach,o=F.E.S.INC., A' Sh°b PE43414, Notes: Site: 6903 SALERMO ROAD °ss "'':202103�`e7:11:1 ❑nilmm° oae:zoz1 o324 n:na4-o4'00• FORT PIERCE,FL34951 Ad°b,Aa°bat 2021,00120145 =9or nA m°,ctlenrea�o�� Design • • Weather: West Palm Beach Intl AP,FL,US Winter Design Conditions Summer Design Conditions Outside db 48 °F Outside db 91 °F Inside db 68 °F Inside db 75 °F Design TD 20 °F Design TD 16 °F Daily range L Relative humidity 50 % Moisture difference 57 gr/Ib Heating Summary Sensible Cooling Equipment Load Sizing Structure 11319 Btuh Structure 17482 Btuh Ducts 0 Btuh Ducts 2512 Btuh Central vent(74 cfm) 1606 Btuh Central vent(74 cfm) 1304 Btuh Outside air Outside air Humidification 0 Btuh Blower 0 Btuh Piping 0 Btuh Equipment load 12925 Btuh Use manufacturer's data n Rate/swin multiplier 0.96 Infiltration Equipmen�sensible load 20446 Btuh Method Simplified Latent Cooling Equipment Load Sizing Construction quality Average Fireplaces 0 Structure 4243 Btuh Ducts 0 Btuh Central vent(74 cfm) 2882 Btuh Heating Cooling Outside air Area(ft�) 1222 1222 Equipment latent load 7125 Btuh Volume(ft3) 10998 10998 Air changes/hour 0.35 0.35 Equipment Total Load(Sen+Lat) 27572 Btuh Equiv.AVF(cfm) 64 64 Req.total capacity at 0.70 SHR 2.4 ton Heating Equipment Summary Cooling Equipment Summary Make Make Trade Trade Model Cond AHRI ref Coil AHRI ref Efficiency 80AFUE Efficiency 0 SEER Heating input 0 Btuh Sensible cooling 0 Btuh Heating output 0 Btuh Latent cooling 0 Btuh Temperature rise 0 °F Total cooling 0 Btuh Actual airflow 795 cfm Actual airflow 795 cfm Air flow factor 0.070 cfm/Btuh Air flow factor 0.040 cfim/Btuh Static pressure 0 in H2O Static pressure 0 in H2O Space thermostat Load sensible heat ratio 0.75 Bolc0talic values have been manually overridden Calculations approved byACCA to meet all requirements of Manual J 8th Ed. wrightsoft" 2021-Mar-23 23:44:07 M,a Right-Sute®Uriversal 20l9 l9.0.15 RSU25464 Page 1 '�Cp` ...4951\Single Family Home(6903 Salermo Road).rup Calc=MJ8 House faces:W