Certification for Design Load Compliance
7t" Edition
Project Name: 6903 Salerno Road
Project Address: 6903 Salerno Road
Permit#: Occupancy Type:R-3 Construction Type:IV
INSTRUCTIONS FOR USE:
• This certification must be completed,signed,and sealed by the design professional of record.
• If submitting hard copy,submit(2)copies with all pertinent information.St Lucie Fire District requires a digitally
signed electronic version.
• If submitting electronically,form should be uploaded into Bluebeam.Separate submission to Fire is still required
• All digital files must be in an unlocked Portable Document Format(PDF)version
* Note: Form not required for interior renovations provided that no exterior structural elements are affected and
certain minor building permits at the discretion of the plan reviewer. Contact the#above for questions.
DESIGN PARAMETERS AND ASSUMPTIONS USED: (complete all that apply)
1. DESIGN CODE: Florida Building Code 7th Edition using ASCE 7-16
2. Structure Designed as(check one): X Enclosed Partially Enclosed Open
3. Risk Category: I X II III IV Exposure Category:-B X C D
4. Design Wind Velocity 160 mph ASD X LRFD End Zone Width: ft
5. Mean Roof Height 13.416 ft Roof Pitch:4 :12 Parapet: NSA ft
6. Components&Cladding Design Pressures Used:
Zone 4:41.50/45.01Zone 5: 35.03/42.63 Garage: 35.03/42.63
6a. Roofs
Maximum+/-pressures:+ psf - psf Or define individual zones on the plans
7. Design Loads: Floor: 100 TTL PSF Roof-Dead: 15 TC PSF Roof-Live:30 TC Balcony+/-NSA PSF
Dock: NSA PSF Deck: NSA PSF Stairs:40 PSF Fence: NSA PSF Railings:200 CL PSF
8. Were Shear Walls Considered For Structure?X Yes Not Applicable Please Explain:
9. Is a Continuous Load Path Provided?X Yes Not Applicable Explain Why Not:
10. Design Soil Bearing Pressure:2500 PSF Soil Test Reports Submitted? x Yes No Assumed
DESIGN PROFESSIONAL CERTIFICATION STATEMENT:
I certify that, to the best of my knowledge and belief, the attached plans & specifications have been designed to
comply with the applicable structural portions of the current Florida Building Code as adopted.
,E OF F(OR
Digitally signed by
P
y,. Scott B Disher
_ as nN•r=1I� Scott Disher AR 11586
Sit Ac'..,"""° aS(pVnaffiliated, _Print Name Cert#&Co.CertofAuthorization
srFREDAROa ou=A01 41 00000001 74
BCOA11FD0000E4FC,
"'<'°°n ,,,, cn=Scott B Disher
Date:2021.04.20 Architectural Studio, Inc., Palm Beach Gardens, FL
g m« < 10:00:59-04'00'
Revi— Company Name&Address