Wind Load Calculations
(cats �0 V�EVWED FOR CODE COMPLIANCE ST. LUCEE COUNTY to.NEMOjetc. TABLE DECK APPLICATION TYPE DESCRIPTION PAGE 1A Wood New or Reroof (Tear -Off) A-1 Bonded Insulation, Bonded Roof Cover 2 1B Wood New or Reroof (Tear -Off) A-2 Mech. Attached Anchor Sheet, Bonded Insulation, Bonded Roof Cover 3 1C Wood New, Reroof (Tear -Off) or Recover C-1 Mechanically Attached Insulation, Bonded Roof Cover 3 1D Wood New, Reroof (Tear -Off) or Recover D-2 Insulated, Mech. Attached Base Sheet, Bonded Roof Cover 4 1E Wood New or Reroof (Tear -Off) E-2 Non -Insulated, Mech. Attached Base Sheet (nails), Bonded Roof Cover 4-5 SF Wood New, Reroof (Tear -Off) or Recover E-2 Non -Insulated, Mech. Attached Base Sheet (screws & plates), Bonded Roof Cover 6 1G Wood New or Reroof (Tear -Off) F Non -Insulated, Bonded Roof Cover 6 The following notes apply to the systems outlined herein: 1 'The roof system evaluation herein pertains to above -deck roof components. Roof decks and structural members shall be in accordance with FBC requirements to the satisfaction of the Authority Having Jurisdiction. 2 Fasteners shall be of sufficient length for the following engagements: ➢ Wood Deck: Min. 0.75-inch plywood penetration or minimum 1-inch wood plank embedment. 3 Unless otherwise noted, insulation may be any one layer or combination of FBC Approved (Local or Statewide) board(s) that meet FBC 1505 and, for foam plastic, FBC Chapter 26, when installed with the roof cover. 4 Minimum 200 psi, minimum 2-inch thick FBC Approved lightweight insulating concrete may be substituted for rigid insulation board for System Types B-1, C-1, C-2, D-1 or D-2, whereby fasteners are installed through the lightweight insulating concrete to engage the structural deck. The structural deck shall be of equal or greater type, thickness and strength to the steel and structural concrete deck listings. Roof decks and structural members shall be in accordance with FBC requirements to the satisfaction of the Authority Having Jurisdiction. This is a wind uplift resistance allowance and does not purport to address non - wind -uplift -related issues, such as deck venting or moisture levels within the LWIC and the potential effect on overlying components. 5 Preliminary insulation attachment for System Type D: Unless otherwise noted, refer to Section 2.2.10.1.3 of FM Loss Prevention Data Sheet 1-29 (February 2020). 6 Unless otherwise noted, insulation adhesive application rates are as follows. Ribbon or bead width is at the time of application; the ribbons/beads shall expand as noted in the manufacturer's published instructions. ➢ RESISTOBOND: Continuous 0.5 to 0.75-inch wide ribbons, max.12-inch o.c. ➢ DuPont INSTA STIK Quik Set Insulation Adhesive (INSTA STIK): Continuous 0.75 to 1-inch wide ribbons, max.12-inch o.c. ➢ OMG OlyBond 500: Continuous 0.75 to 1-inch wide ribbons, max. 12-inch o.c. ➢ Note: When multiple layers(s) of insulation and/or coverboard are installed in ribbon -applied adhesive, board joints shall be staggered. ➢ Note: The maximum edge distance from the adhesive ribbon to the edge of the insulation board shall be not less than one-half the specified ribbons spacing. 7 Unless otherwise noted, all insulations are flat -stock or taper board of the minimum thickness noted. 8 For adhered,roof insulation and board -size: Unless otherwise noted, refer to Section 2.2.10.6.2 of FM Loss Prevention Data Sheet 1-29 (February 2020). 9 For mechanically attached components or partially -bonded insulation, the maximum design pressure for the selected assembly shall meet or exceed at least the Zone 1 PRIME design pressure determined in accordance with FBC Chapter 16. Elevated pressure zones shall employ an attachment density designed by a qualified design professional to resist the elevated pressure criteria. Commonly used methods are ANSI/SPRI WD1, FM Loss Prevention Data Sheet 1-29, Roofing Application Standard RAS 117 and Roofing Application Standard RAS 137. Assemblies marked with an asterisk* carry the limitations set forth in Section 2.2.10.1 of FM Loss Prevention Data Sheet 1-29 (February 2020) for Zone 2/3 enhancements. 10 For assemblies with all components fully bonded, the maximum design pressure for the selected assembly shall meet or exceed critical design pressure determined in accordance with FBC Chapter 16. No rational analysis is permitted for these systems. NEMO ETC, LLC Evaluation Report 7215.06.14-R9 for FL37084-119 Certificate of Authorization #32455 7TM EDITION (2020) FBC NON-HVHZ EVALUATION Revision 9: 09/18/2020 ©2019 NEMO ETC, LLC RESISTO, a division of Soprema, Inc.; (819) 478-2400 Appendix 1, Page 1 of 6 O_NEmoletc. 11 For mechanically attached components over existing decks, fasteners shall be tested in the existing deck for withdrawal resistance. A qualified design professional shall review the data for comparison to the minimum requirements for the system. Testing and analysis shall be in accordance with ANSI/SPRI FX-1 or Testing Application Standard TAS 105. 12 For bonded insulation or membrane over existing substrates in a re -roof (tear off) or recover installation, the existing deck or existing roof surface shall be examined for compatibility with the adhesive to be installed. If any surface conditions exist that bring system performance into question, field uplift testing in accordance shall be conducted on mock-ups of the proposed new roof assembly. For bonded insulation or membrane over existing substrates in a recover installation, the existing roof system shall be capable of resisting project design pressures on its own merit to the satisfaction of the Authority Having Jurisdiction, as documented through field uplift testing. Field uplift testing shall be in accordance with ASTM E907, FM Loss Prevention Data Sheet 1-52 or Testing Application Standard TAS 124. 13 Refer to FBC 1511 for requirements and limitations regarding recover installations. For Structural Concrete Deck or Recover Applications using System Type C-1, C-2, D-1 or D-2, the insulation is optional. Alternatively, an FBC Approved insulation board or coverboard may be used as a separation layer. Board products shall be preliminarily attached prior to roof cover installation (Note 5 herein). The separator component shall be documented as meeting FBC 1505 and, for foam plastic, FBC Chapter 26, when installed with the roof cover in Recover applications. 14 Lightweight insulating concrete (LWIC) shall be cast in accordance with FBC Section 1917 to the satisfaction of the Authority Having Jurisdiction. For systems where specific LWIC is referenced, refer to current LWIC Product Approval for specific deck construction and limitations. Unless otherwise noted, for systems where specific LWIC is not referenced, the minimum design mix shall be 300 psi. In all cases, the minimum top -coat thickness is 2-inches. For LWIC over structural concrete, reference is made to FBC Section 1917.4.1, Point 1. For "pre-existent" LWIC references, listings were established through testing over lightweight concrete cast using only foaming agent (ASTM C896), water and Portland cement (ASTM C150), with no proprietary additives, in accordance with procedures adopted by Miami -Dade BCCO (FBC CER1592). Use of these listings in new construction or re -roof (tear -off) applications is at the discretion of the Designer or Record and Authority Having Jurisdiction. 15 For bonded membrane applications, refer to the tables herein. The following are acceptable alternates to the listed membranes. ACCEPTABLE ALTERNATES RESISTO Product Alternate RESISTO LB1236 Beacon Roofing'TRI-BUILT Sand-R SA Shingle Underlayment" PrimeSource Building Products "Grip -Rite Eave & Valley Protector" SRS Distribution'TopShield ICE & WATER DEFENDER" 16 A slip -sheet of Modified Sopra-G or other approved ASTM D4601, Type II fiberglass base sheet may be loose laid atop the wood deck prior to the installation of overlying mechanically fastened components with no adverse effect on system performance. 17 "MDP" = Maximum Design Pressure is the result of testing for wind load resistance based on allowable wind loads. Refer to FBC 1609 for determination of design wind loads TABLE IA: ••r rECKS — NEW CONSTRUCTION OR REROOF (TEAR -OFF) SYSTEM TYPE A-1: BONDED INSULATION,BONDED ROOF COVER System Deck Base Insulation Layer Top Insulation Layer(s) Roof Cover (Note 15) Type Attach Type Attach Primer Base Ply Ply Cap Ply No. (Note 1) MDP (psf) (Notes 6,7,8) (Notes 6,7,8) APA rated, 7/16 CAT, 0.418 in., Min.1.5-inch RESISTOBOND, (Optional) RESISTOBOND, (Optional) (Optional) RESISTO BITUTAK MB W 1 Exposure 10SB, min.15/32" ACFoam II, SOPRA- INSTA STIK or Additional INSTA STIK or RESISTO RESISTO RESISTO BITUTAK SMOOTH or RESISTO -52.5 APA rated plywood or nominal ISO s, H-Shield or OlyBond 500, layers(s) base OlyBond 500, EXTERIOR a,self- adhering dheri MB SMOOTH, BITUTAK MB MINERAL, 1" T&G wood plank SOPRA-ISO r 12" o.c. insulation 12" o.c. PRIMER torch -applied torch -applied APA rated, 7/16 CAT, 0.418 in., Min.1.5-inch RESISTOBOND, (Optional) RESISTOBOND, (Optional) (Optional) RESISTO BITUTAK MB W 2' Exposure 1 OSB, min. 15/32" ACFoam II, SOPRA- INSTA STIK or Additional INSTA STIK or RESISTO RESISTO RESISTO BITUTAK SMOOTH or RESISTO APA rated plywood or nominal ISO s, H-Shield or OlyBond 500, layers(s) base OlyBond 500, 6" EXTERIOR LB3236, self- MB SMOOTH, BITUTAK MB MINERAL, -105.0 1" T&G wood plank SOPRA-ISO r 6" O.C. insulation O.C. PRIMER adhering torch -applied torch -applied NEMO ETC, LLC Evaluation Report 7215.06.14-119 for FL17084-R9 Certificate of Authorization #32455 7- EDITION (2020) FBC NON-HVHZ EVALUATION Revision 9: 09/18/2020 ©2019 NEMO ETC, LLC RESISTO, a division of Soprema, Inc.; (819) 478-2400 Appendix 1, Page 2 of 6 1 O.''INEMICI I etc. TABLE IB: .. . • REROOF SYSTEM TYPE A-2: MECHANICALLY ATTACHED ANCHOR SHEET, BONDED INSULATION, BONDED ROOF COVER Anchor Sheet Base Insulation Layer(s) Top Insulation Layer Roof Cover (Note 15) System No. Deck (Note 1) Primer MDP (psf) Type Fasteners Attach Type Attach Type Attach Base Ply Ply Cap Ply (Note 11) (Notes 6,7,8) (Notes 6,7,8) APA rated, 7/16 32 ga., 1-5/8- 8-inch o.c. at 4- (Optional) RESISTO CAT, 0.418 in., inch diameter inch wide side Min. 1.5-inch RESISTOBOND, (Optional) RESISTOBOND, (Optional) RESISTO RESISTO BITUTAK MB Exposure 1 OSB, tin caps with laps and 8-inch ACFoam II, INSTA STIK or Additional INSTA STIK or RESISTO LB1236, BITUTAK MB \ SMOOTH or W-3. min. 15/32" APA SA Nail Base o.c. at three (3) SOPRA-ISO s, layers(s) RESISTO -30.0,� rated plywood 12 ga. equally spaced H-Shield or OlyBond 500, base OlyBond 500, EXTERIOR self- SMOOTH, BITUTAK MB annular ring 12" o.c.12" o.c. PRIMER adhering torch - or nominal 1" rows in the center SOPRA-ISO rinsulation MINERAL, T&G wood plank shank nails of the sheet applied torch -applied APA rated, 7/16 32 ga., 1-5/8- 6-inch o.c. at 4- (Optional) RESISTO CAT, 0.418 in., inch diameter inch wide side Min. 1.5-inch (Optional) (Optional) RESISTO RESISTO BITUTAK MB Exposure 1 OSB, tin caps with laps and 6-inch ACFoam II, INSTA STIK, 12" Additional INSTA STIK, 12" RESISTO L81236, BITUTAK MB SMOOTH or W-4. min. 15/32" APA RESISTOFLEX o.c. at three (3) SOPRA-ISO s, layers(s) RESISTO -37.5• rated plywood 12 equally spaced H-Shield or O.C. base O.C. EXTERIOR self- SMOOTH, BITUTAK MB or nominal 1" u annular ring rows in the center SOPRA-ISO r insulation PRIMER adhering torch- MINERAL, T&G wood plank shank nails of the sheet applied torch -applied APA rated, 7/16 32 ga.,1-5/8- 6-inch o.c. at 4- (Optional) RESISTO CAT, 0.418 in., inch diameter inch wide side Min. 1.5-inch (Optional) (Optional) RESISTO RESISTO BITUTAK MB Exposure 1 OSB, tin caps with laps and 6-inch ACFoam II, INSTA STIK, 6" Additional INSTA STIK, 6" RESISTO LB3236, BITUTAK MB SMOOTH or W-5. min. 15/32" APA RESISTOFLEX 12ga. o.c. at four (4) SOPRA-ISO s, O.C. layers(s) O.C. EXTERIOR self- SMOOTH RESISTO -75.0 rated plywood annular ring equally spaced H-Shield or base PRIMER adhering , torch- BITUTAK MB or nominal 1" rows in the center SOPRA-ISO r insulation MINERAL, T&G wood plank shank nails of the sheet applied torch -applied TABLE 1C: WOOD DECKS —NEW CONSTRUCTION, REROOF (TEAR -OFF) OR RECOVER SYSTEMTYPEC-1: MECHANICALLY ATTACHED INSULATION, BONDED ROOF COVER Top Insulation Layer Roof Cover (Note 15) System Deck Base Insulation MDP No. (Note 1) (Note 13) Type Fasteners Attach Primer Base Ply Ply Cap Ply (Psf) (Note 11) Min. 15/32-inch (Optional) One or more Min.1.5-inch ACFoam II, Soprema #12 DP (Optional) W-6. APA rated layers, any SOPRA-ISO s, H-Shield, Fasteners with 1 per 1.6 RESISTO SA Smooth Ply None SA Cap GR or SA Cap FR -67.5 plywood at max. combination, loose laid SOPRA-ISO r Soprema 3" Metal ft Z EXTERIOR 40 GR 24-inch spans Insulation Plates PRIMER Min. 15/32-inch (Optional) One or more Min. 1.5-inch ACFoam II, Soprema #12 DP (Optional) RESISTO (Optional) RESISTO BITUTAK MB W-7. APA rated layers, any SOPRA-ISO s, H-Shield, Fasteners with 1 per 1.6 RESISTO L61236, self- RESISTO BITUTAK SMOOTH or RESISTO -67.5 plywood at max. combination, loose laid SOPRA-ISO r Soprema 3" Metal ftft2 EXTERIOR adhering MB SMOOTH, BITUTAK MB MINERAL, 24-inch spans Insulation Plates PRIMER torch -applied torch -applied NEMO ETC, LLC Certificate of Authorization #32455 ©2019 NEMO ETC, LLC 7T" EDITION (2020) FBC NON-HVHZ EVALUATION RESISTO, a division of Soprema, Inc.; (819) 478-2400 Evaluation Report 7215.06.14-119 for FL37084-119 Revision 9: 09/18/2020 Appendix 1, Page 3 of 6 TABLE ID: WOOD DECKS — NEW CONSTRUCTION, REROOF (TEAR -OFF) OR RECOVER SYSTEM TYPE rINSULATED, MECHANICALLY ATTACHED: BONDED ROOF COVER Base Sheet Roof Cover (Note 15) System Deck (Note 1) MDP Insulation Layer(s) Fasteners No. (Note 13) Type Attach ' Base Ply Ply • Cap Ply IPsfl (Note 11) APA rated, 7/16 CAT, 0.418 One or more layers, min. Trufast #12 DP with 8-inch o.c. at the 4-inch laps (Optional) RESISTO BITUTAK MB W 8' in., Exposure 1 OSB, min. any combination, SA Nail Trufast 3" Metal and at three RESISTO LB1236, RESISTO BITUTAK SMOOTH or RESISTO 82 5 15/32" APA rated plywood or loose -laid loose-lnch,aid Base Insulation Plates rows equally spaced center rows flinch spaced self -adhering MB SMOOTH, BITUTAK MB MINERAL, nominal 1" T&G wood plank torch -applied torch -applied APA rated, 7/16 CAT, 0.418 One or more layers, min. Trufast #12 DP with 8-inch o.c. at the 4-inch laps (Optional) (Optional) RESISTO BITUTAK MB W 9' in., Exposure 1 OSB, min. any combination, MODIFIED Trufast 3" Metal and at three RESISTO BITUTAK RESISTO BITUTAK SMOOTH or RESISTO -120.0 15/32" APA rated plywood or loose -laid loose-lnch,aid SOPRA-G Insulation Plates rows equally spaced center rows flinch spaced MB SMOOTH, MB SMOOTH, BITUTAK MB MINERAL, nominal i" T&G wood plank torch -applied torch -applied torch -applied TABLE IE: ••r rECKS— NEW CONSTRUCTION OR REROOF (TEAR -OFF) SYSTEM TYPE E-2: NON -INSULATED, MECHANICALLY ATTACHED BASE SHEET (NAILs), BONDED ROOF COVER Base Sheet Roof Cover (Note 15) System No., Deck Note 1 ( ) Primei MDP (psf) Base. Fasteners Attach Base Ply Primer Ply Cap Ply (Note 11) 32 ga., 1-5/8-inch 8-inch o.c. at 4-inch wide (Optional) APA rated, 7/16 CAT, side laps and 8-inch o.c. at RESISTO RESISTO BITUTAK MB W-10. 0.418 in., Exposure 1 SA Nail diameter tin caps with three (3) equally spaced None LB1236, self- None RESISTO BITUTAK SMOOTH or RESISTO BITUTAK -30.0„ OSB Base 12 ga. annular ring rows in the center of the adhering MB SMOOTH, MB MINERAL, torch -applied shank nails torch -applied sheet Min. 7/16-inch OSB or SOPRA-G 32 ga., 1-5/8-inch 6-inch o.c. at the 4-inch RESISTO RESISTO W-11, min. 15/32-inch APA or diameter tin caps with laps and 6-inch o.c. at four EXTERIOR SA Base EXTERIOR None SA Cap GR or SA Cap FR GR -37.5 , MODIFIED 11 ga. annular ring (4), equally spaced, rated plywood SOPRA-G shank nails staggered center rows PRIMER PRIMER 32 ga., 1-5/8-inch 7-inch o.c. at the 4-inch Min. 19/32-inch APA diameter tin caps with laps and 7-inch o.c. at RESISTO RESISTO W-12. SOPRA-G EXTERIOR SA Base EXTERIOR None SA Cap GR or SA Cap FR GR -37.5 rated plywood 11 ga. annular ring three (3), equally spaced, shank nails staggered center rows PRIMER PRIMER 32 ga., 1-5/8-inch 8-inch o.c. at the 4-inch Min. 15/32-inch APA SA Nail diameter tin caps with laps and 8-inch o.c. at (Optional) SA W-13. rated plywood Base 11 ga. annular ring three (3), equally spaced, None Smooth Ply 40 None None SA Cap GR or SA Cap FR GR 45.0 shank nails staggered center rows 32 ga., 1-5/8-inch 8-inch o.c. at the 4-inch (Optional) Min. 15/32-inch APA SA Nail diameter tin caps with laps and 8-inch o.c. at RESISTO RESISTO BITUTAK RESISTO BITUTAK MB W-14. None None SMOOTH or REBITUTAK -45.0 rated plywood Base 11 ga. annular ring three (3), equally spaced, aLB1236,self- adhering dheri MB SMOOTH, MB MINERAL, torch -applied rch-applied shank nails staggered center rows torch -applied NEMO ETC, LLC Certificate of Authorization #32455 ©2019 NEMO ETC, LLC 7T" EDITION (2020) FBC NON-HVHZ EVALUATION RESISTQ, dvision;of Soprema, Inc"s•. 819) 478-2400 Evaluation Report 7215.06.14-119 fo FL17084-R9. Revision 9: 09/18/2020 Appendix 1, Page 4 of 6 0.'NEMOjetc. TABLE IF: rrr rCONSTRUCTION,•.. . .. RECOVER SYSTEM TYPE E-2: NON -INSULATED, MECHANICALLY ATTACHED BASE SHEET (SCREWS & PLATES), BONDED ROOF Base Sheet Roof Cover (Note 15) System Deck ( Note i) No. MDP (Psfl Base Fasteners Attach Primer Base Ply Primer Ply Cap Ply (Note 11) Min.19/32-inch APA rated plywood or SA Nail Trufast #12 DP with 8-inch o.c. at the 4-inch laps (Optional) SA W-24. nominal 1" T&G wood Base Trufast 3' Metal and 8-inch o.c. at three (3), None Smooth Ply 40 None None SA Cap GR or SA Cap FR GR -127.5 plank Insulation Plates equally spaced center rows Min. 19/32-inch APA (Optional) rated plywood or SA Nail Trufast #12 DP with 8-inch o.c. at the 4-inch laps RESISTO RESISTO BITUTAK RESISTO BITUTAK MB W-25. nominal 1" T&G wood Base Trufast 3" Metal and 8-inch o.c, at three (3), None LB1236, self- None MB SMOOTH, SMOOTH or RESISTO BITUTAK -127.5 plank Insulation Plates equally spaced center rows adhering torch -applied MB MINERAL, torch -applied TABLE 1G: r.r r CONSTRUCTION OR REROOF (TEAR -OFF) SYSTEM TYPE F: r BONDED ROOF COVER System Roof Cover (Note 15) Deck (Notes 1 & 12) Primer MDP (psf) No. Base Ply Primer Ply Cap Ply Min. 7/16-inch APA rated OSB or min. RESISTO EXTERIOR RESISTO EXTERIOR W 26 15/32-inch APA rated plywood PRIMER SA Base PRIMER None SA Cap GR or SA Cap FR GR -45.0 W-27. Min. 15/32-inch APA rated OSB None SA Smooth Ply 40 None None SA Cap GR or SA Cap FR GR -67.5 W-28. Min. 15/32-inch APA rated OSB RESISTO EXTERIORPRIMER SA Smooth -Ely 40 None None SA Cap GR or SA Cap FR GR -75.0 W-29. APA rated, 7/16 CAT, 0.418 in., Exposure (Optional) RESISTO RESISTO LB1236, None (Optional) RESISTO BITUTAK RESISTO BITUTAK MB SMOOTH or RESISTO""" +e+� -97.5 1 OSB, min. 15/32" APA rated plywood EXTERIOR PRIMER self-adheri0g , M_B SMOOTH, torch -applied , BITUTAKMB MINERAL, t, arch -applied. 3r W-30. Min. 15/32-inch APA rated plywood None Ply 40 None None ' `SA Cap GR or 5A Cap FR-GR -105.0 W-31. Min. 15/32-inch APA rated I plywood RESISTO EXTERIOR SA Smooth Ply 40 None None SA Cap GR or SA Cap FR GR -112.5 PRIMER (Optional) RESISTO RESISTO LB1236, (Optional) RESISTO BITUTAK RESISTO BITUTAK MB SMOOTH or RESISTO W-32. Nominal 1" T&G wood plank EXTERIOR PRIMER self -adhering None MB SMOOTH, torch -applied BITUTAK MB MINERAL, torch -applied -135.0 NEMO ETC, LLC Certificate of Authorization #32455 ©2019 NEMO ETC, LLC 7T" EDITION (2020yFBC_NON H.VHZE_V�ALUATION RES15TO, a division of Soprema, Jnc;,(§19) 478-2400 Evaluation Report 7215.06.14-R9 for _6bb84.,R%,,, Revision 9: 09/18/2020 Appendix 1, Page 6 of 6 TABLE 1E: WOOD DECKS — NEW CONSTRUCTION OR REROOF (TEAR -OFF) SYSTEM TYPE E.-2: NON -INSULATED, MECHANICALLY ATTACHED BASE SHEET (NAILs), BONDED ROOF COVER Base Sheet Roof Cover;(Note 15) System Y No. - Deck (Note 1 ( ) Primer MDP (Pso Base Fasteners Attach : Base Ply Primer Ply Cap Ply (Note 11) Min.15/32-inch OSB 32 ga.;1-5/8-inch 6-inch o.c. at the 4-inch RESISTO RESISTO W-15. or min.15/32-inch SOPRA-G diameter tin caps with laps and 6-inch o.c. at four EXTERIOR SA Base EXTERIOR None SA Cap GR or SA Cap FR GR -45.0 APA rated plywood 11 ga. annular ring (4), equally spaced, PRIMER PRIMER shank nails staggered center rows 32 ga., 1-5/8-inch 6-inch o.c. at the 4-inch (Optional) Min. 15/32-inch APA SA Nail diameter tin caps with laps and 6-inch o.c. at four RESISTO RESISTO BITUTAK RESISTO BITUTAK MB W-16. rated plywood Base 12 ga. annular ring (4), equally spaced, None ,self- None MB SMOOTH, SMOOTH or REBITUTAK 52.5 a adhering dheri MB MINERAL, torch -applied rch applied shank nails staggered center rows torch -applied Min. 19/32-inch APA 32 ga., 1-5/8-inch 8-inch o.c. at the 4-inch W 17.. rated plywood or SA Nail diameter tin caps with laps and 8-inch o.c. at . None (Optional) SA None None ' a SA Cap GR or SA Cap FR.GR 60.0 : nominal 1" T&G wood Base 11 ga. annular ring three (3), equally spaced • Smooth Ply 40 plank shank nails center rows Min. 19/32-inchAPA 32 ga., 1-5/8-inch 8-inch o.c. at the 4-inch (Optional) rated plywood or SA Nail diameter tin caps with laps and 8-inch o.c. at RESISTO RESISTO BITUTAK RESISTO BITUTAK MB W 18. nominal 1" T&G wood Base 11 ga. annular ring three (3), equally spaced None ,self- None MB SMOOTH, SMOOTH or REBITUTAK 60.0 plank shank nails center rows a adhering dheri torch -applied rch-applied MB MINERAL, torch -applied APA rated, 7/16 CAT, GAP 6-inch o.c, at the 3-inch (Optional) (Optional) 0.418 in., Exposure 1 Organic Simplex MAXX Cap laps and 6-inch o.c, at RESISTO RESISTO BITUTAK RESISTO BITUTAK MB W-19. OSB or min.15/32- Base Fastener three (3), equally spaced None BITUTAK MB None MB SMOOTH, SMOOTH or RESISTO BITUTAK -60.0 inch APA rated Sheet center rows SMOOTH, torch -applied MB MINERAL, torch -applied plywood (#43) torch -applied Min. 19/32-inch APA 32 ga., 1-5/8-inch 6-inch o.c. at the 4-inch W-20. rated plywood or SA Nail diameter tin caps with laps and 6-inch o.c. at None (Optional) SA None None SA Cap GR or SA Cap FR GR -90.0 nominal 1" T&G wood Base 0.120" x 1.25" ring three (3), equally spaced Smooth Ply 40 plank shank roofing nails center rows Min. 19/32-inch APA 32 ga., 1-5/8-inch 6-inch o.c. at the 4-inch RESISTO (Optional) RESISTO BITUTAK MB W 21. rated plywood or SA Nail diameter tin caps with laps and 6-inch o.c. at None None RESISTO BITUTAK SMOOTH or REBITUTAK -90.0 nominal 1" T&G wood Base 0.120" x 1.25" ring three (3), equally spaced a,self- dheri adhering MB SMOOTH, rch applied MB MINERAL, torch -applied plank shank roofing nails center rows torch -applied Min. 19/32-inch APA 32 ga., 1-5/8-inch 4-inch o.c. at the 4-inch W 22. rated plywood or SA Nail diameter tin caps with laps and 4-inch o.c. at four None (Optional) SA None None SA Cap GR or SA Cap FR GR -105.0 nominal 1" T&G wood Base 0.120" x 1.25" ring (3), equally spaced center Smooth Ply 40 plank s shank roofing nails rows Min.19/32-inch APA 32 ga., 1-5/8-inch 4-inch o.c. at the 4-inch RESISTO (Optional) RESISTO BITUTAK MB W 23. rated plywood or SA Nail diameter tin caps with laps and 4-inch o.c, at four None None RESISTO BITUTAK SMOOTH or -105.0 nominal 1" T&G wood Base 0.120" x 1.25" ring (3), equally spaced center ,self adhering adhering MB SMOOTH, MB MINERAL, torch applied , torch -applied plank shank roofing nails rows torch -applied NEMO ETC, LLC Evaluation Report 7215.06.14-119 for FL17084-119 Certificate of Authorization #32455 7'" EDITION (2020) FBC NON-HVHZ EVALUATION Revision 9: 09/18/2020- ti ©-2019 NEMO ETC, LLC RESISTO, a division of Soprema, Inc.; (819) 478-2400 Appendix 1, Page 5 of 6