HomeMy WebLinkAboutCompaction test Creekside Lot 43-digio���NTr� • cFol�Os
g 2Universal
w
m
02Sciences
G
9`S TFSTING'Company
•
UES Project No: 3360.1800067.0000
Workorder No: 237058-1
Report Date: 06/18/2021
607 Northwest Commodity Cove, Port St. Lucie, FL 34986 - P: 772-924-3575 - F: 772-924-3580
In -Place Density Test Report
Client: D.R. HORTON, INC. EAST FLORIDA DIVISION UES Technician: Mark Rogers
1430 Culver Drive, NE Date Tested: 06/18/2021
Palm Bay, FL 32907
Project: CMT CREEKSIDE
Yorktown Drive & Okeechobee Road,Fort Pierce, St Lucie County, FL
Area Tested: Lot 43 - 3318 Trinity Circle, Ft. Pierce
Material: Backfill
Reference Datum: 0 = Top of Final Grade
The tests below meet the 95% minimum compaction requirement.
Type of Test:
Field: ASTM D-6938 Nuclear Gauge Method
Laboratory: ASTM D1557 Modified Proctor
Maximum
Optimum
Field Dry
Field
Soil
Pass
Test
Density
Moisture
Density
Moisture
Compaction
or
No.
Location of Test
Range
(pcf)
(%)
(pcf)
(%)
(%)
Fail
1
Northeast corner of lot
0-1 ft
118.6
10.8
114.1
10.5
96
Pass
2
Southeast corner of lot
0-1 ft
118.6
10.8
116.1
10.6
98
Pass
3
Center of lot
0-1 ft
118.6
10.8
115.5
10.3
97
Pass
Remarks: The in -place density tests were performed within the foundation/building pad footprint of the referenced residential lot. The test
results either meet or exceed the requirements of the FHA/HUD manual and the current edition of the Florida Building Code for soil
compaction. The Contractor is responsible for maintaining the tested soil subgrade in the same condition that existed at the time
GFA performed the referenced density tests. GFA is not responsible if the tested area is altered from the approved condition at
the time of testing.
Permit: 2011-0167
Reviewed By
GFA International, Inc
FBPE Registry No.4930
John Digitally signed
by John Kent
Date: 2021.06.18
Kent
15:47:28-04'00'
John Kent
Senior Project Engineer
STATE OF FLORIDA
Professional Engineer No. 63218
This item has been digitally signed and sealed by John Kent on the
date adjacent to the seal. Printed copies of this document are not
considered signed and sealed and the signature must be verified on
any electronic copies.
To establish a mutual protection to Universal's clients, the Public and ourselves, all reports are submitted as confidential property of our clients and
authorization for publication of statements, conclusions or extracts from or regarding Universal's reports is reserved pending our written approval.
Page 1