Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
APPLICATION FOR BUILDING PERMIT REVISIONS 6-4-21
OFFICE USE ONLY: "A , 1 DATE FILED: Ul' REVISION FEE: LOCATION/SITE ADDRESS: PERMIT # / 90 { '1)"7a L RECEIPT # PLANNING & DEVELOPMENT SERVICES BUILDING & CODE REGULATION DIVISION 2300 VIRGINIA AVENUE RECEIVED FORT PIERCE, FL 34982-5652 (772) 462.1553 i v)l U 4 2021 St. Lucia county APPLICATION FOR BUILDING PERMIT REVISIONS PROJECT INFORMATION DETAILED DESCRIPTION OF PROJECT CONTRACTOR INFORMATION: STATE of FL REG./CERT. #: I" CZ BUSINESS NAME: A' - QUALIFIERS NAME: ADDRESS: (�Ll CITY: S'Ii,,STATE: PHONE (DAYTIME): ass OWNER/BUILDER INFORMATION: NAME: ADDRESS: �f CITY: STATE: PHONE (DAYTIME: ARCHITECT/ENGINEER INFORMATION: r-c-- S `f Qoo,Z_ ST. LUCIE CO CERT. #: 4� u FAX: ZIP: ZIP: NAME: ADDRESS: CITY: STATE: ZIP: PHONE (DAYTIME): FAX: SLCCC: 9123109 -wAj Re REVISIOReIG"" REGEIvry JUN 0 4 2021 FORM R405-2017 St. Lucie County FLORIDA ENERGY EFFICIENCY CODE FOR ENO. I ING CONSTRUCTION Florida Department of Business and Professional Regulation - Residential Performance Method Project Name: INDIAN RIVER ESTATES LOT 8 Builder Name: COPPER ENTERPRISES Street: SEAGRAPE DRIVE Permit Office: ST. LUCIE COUNTY City, State, Zip: FT. PIERCE, FL, Permit Number: Owner: LOUIS FRISKNEY Jurisdiction: Design Location: FL, Fort Pierce County: St. Lucie (Florida Climate Zone 2 ) 1. New construction or existing New (From Plans) 9. Wall Types (1548.0 sqft.) Insulation Area 2. Single family or multiple family Detached a. Concrete Block - Int Insul, Exterior R=9.0 1353.00 ft2 b. Frame - Wood, Adjacent R=13.0 105,00 ft2 3. Number of units, if multiple family 1 c. N/A R= ft2 4. Number of Bedrooms 3 d. N/A R= Z ft2 5. Is this a worst case? No 10. Ceiling Types (1743.0 sqft.) ulation Area rR a. Cathedral/Single Assembly (Unvente 1743.00 6. Conditioned floor area above grade (ft2) 1743 b. N/A - ft2 Conditioned floor area below grade (ft2) 0 c. N/A R= ft2 11. Ducts R ft2 7. Windows(221.8 sqft.) Description Area a. Sup: Attic, Ret: Attic, AH: Garage 6 333 a. U-Factor: Sgl, U=1.03 148.00 ft2 SHGC: SHGC=0.29 b. U-Factor: Sgl, U=1.03 60.00 ft2 12. Cooling systems kBtu/hr Efficiency SHGC: SHGC=0.27 a. Central Unit 35.4 SEER:17.00 c. U-Factor: Sgl, U=1.01 9.33 ft2 SHGC: SHGC=0.32 13. Heating systems k13tu/hr Efficiency d. U-Factor: other (see details) 4.50 ft2 a. Electric Heat Pump 35.4 HSPF:8.50 SHGC: other (see details) Area Weighted Average Overhang Depth: 5.110 ft. Area Weighted Average SHGC: 0.286 14. Hot water systems a. Electric Cap: 80 gallons 8. Floor Types (1743.0 sqft.) Insulation Area EF: 0.920 a. Slab -On -Grade Edge Insulation R=0.0 1743.00 ft2 b. Conservation features b. N/A R= ft2 Solar:FEF=5.4 c. N/A R= ft2 15. Credits Pstat Glass/Floor Area: 0.127 Total Proposed Modified Loads: 48.91 PASS Total Baseline Loads: 57.75 I hereby certify that the plans and specifications covered by Review of the plans and t iE.STgT this calculation are in compliance with the Florida Energy Code. specifications covered by this calculation indicates compliance,,,,''� .y _ �0� �, `= PREPARED BY: __ with the Florida Energy Code. Before construction is completed urr„�%, =f ::• `'���„ �O I DATE: �=�Q21C this building will be inspected for compliance with Section 553.908 0l✓p1 �. * ° hereby certify that this building, as desi d'' in compliance Florida Statutes. COD with the Florida Energy C W'E'�� OWNER/AGE�F BUILDING OFFICIAL: DATE: DATE: - Compliance requires certification by the air handler unit manufacturer that the air handier enclosure qualifies as certified factory -sealed in accordance with R403.3.2.1. - Compliance requires an Air Barrier and Insulation Inspection Checklist in accordance with R402.4.1.1 and this project requires an envelope leakage test report with envelope leakage no greater than 7.00 ACH50 (114024.1.2). 6/2/2021 4:23 PM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 1 of 4 FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT PROJECT Title: BuildingType: Owner Name: # of Units: Builder Name: Permit Office: Jurisdiction: FamilyType: New/Existing: Comment: INDIAN RIVER ESTATES LO User LOUISFRISKNEY 1 COPPER ENTERPRISES ST. LUCIE COUNTY Detached New (From Plans) Bedrooms: 3 Conditioned Area: 1743 Total Stories: 1 Worst Case: No Rotate Angle: 0 CrossVentilation: Whole House Fan: Address Type: Street Address Lot# Block/Subdivision: PlatBook: Street: SEAGRAPE DRIVE County: St. Lucie City, State, Zip: FT. PIERCE, FL, CLIMATE V DesignLocation TMY Site Design Temp 97.5 % 2.5 % IntDesignTemp Heating Design Daily Temp Winter Summer Degree Days Moisture Range FL, Fort Pierce FL_VERO_BEACH_MUNI 39 90 70 75 299 62 Low BLOCKS Number Name Area Volume 1 Block1 1743 15687 SPACES Number Name Area Volume Kitchen Occupants Bedrooms InfiI1D Finished Cooled Heated 1 Main 1743 15687 Yes 1 3 1 Yes Yes Yes FLOORS # Floor Type Space Perimeter R-Value Area Tile Wood Carpet 1Slab-On-Grade Edgelnsulatio Main 175ft 0 1743 ft2 --_ 1 0 0 ROOF / # Type Materials Roof Gable: Roof Area Area Color Rad Solar SA Emitt EmittDeck Pitch Barr Absor. Tested Tested Insul. (deg) 1 Gable or shed Metal 1888 ft2 362 ft2 Light N 0.6 No 0.9 No 20 22.6 ATTIC V # Type Ventilation Vent Ratio (1 in) Area RBS IRCC 1 Full attic Unvented 0 1743 ft2 N N CEILING # Ceiling Type Space R-Value Ins Type Area Framing Frac Truss Type 1 Cathedral/SingleAssembly(Unvented) Main 0 Blown 1743 ft2 0.11 Wood 6/2/2021 4:23 PM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 2 of 4 FORM R405-21117 INPUT SUMMARY CHECKLIST REPORT WALLS V Space Cavity Width Height Sheathing Framing Solar Below #--OmtAdjacent To � Wa!!_Ty P R-Value Ft In Ft In Area R Ualue-Fraction- Absor-Grad ° 1 NE Exterior Concrete Block- Int Insul Main 9 52 9 468.0 ft2 0 0.6 0 2 SE Exterior Concrete Block - Int Insul Main 9 37 8 9 339.0 ft2 0 0.6 0 3 SW Exterior Concrete Block- Int Insul Main 9 30 6 9 274.5 ft2 0 0.6 0 4 NW Exterior Concrete Block- Int Insul Main 9 30 2 9 271.5 ft2 0 0.6 0 5 NW Garage Frame - Wood Main 13 21 8 9 195.0 ft2 0.23 0.6 0 DOORS # Omt poor Type Space Storms U-Value Width Height Area Ft In Ft In 1 NE Insulated Main None .28 3 6 8 28 ftZ WINDOWS Orientation shown is the entered, Proposed orientation. Wall Overhang # Ornt ID Frame Panes NFRC U-Factor SHGC Imp Area Depth Separation IntShade Screening 1 NE 1 Metal Low-E Single Yes 1.03 0.29 N 15.0 ft2 2 ft 0 in 1 ft 4 in Drapes/blinds None 2 NE 1 Metal Low-E Single Yes 1.03 0.29 N 15.0 ft2 2 ft 0 in 1 ft 4 in Drapes/blinds None 3 NE 1 Metal Low-E Single Yes 1.03 0.29 N 12.0 ft2 2 ft 0 in 1 ft 4 in Drapes/blinds None 4 NE 1 Metal Low-E Single Yes 1.03 0.27 N 60.0 ft2 12 ft 0 in 1 ft 4 in Drapes/blinds None 5 NE 1 Metal Low-E Single Yes 1.03 0.29 N 15.0 ft2 2 ft 0 in 1 ft 4 in Drapes/blinds None 6 SE 2 Metal Low-E Single Yes 1.03 0.29 N 15.0 ft2 2 ft 0 in 1 ft 4 in Drapes/blinds None 7 SE 2 Metal Low E Single Yes 1.03 0.29 N 15.0 ft2 2 ft 0 in 1 ft 4 in Drapes/blinds None 8 SE 2 Metal Low-E Single Yes 1.06 0.29 N 4.5 ft2 2 ft 0 in 1 ft 4 in Drapes/blinds None 9 SW 3 Metal Low-E Single Yes 1.03 0.29 N 15.0 ft2 2 ft 0 in 1 ft 4 in Drapes/blinds None 10 SW 3 Metal Low-E Single Yes 1.03 0.29 N 15.0 ft2 5 ft 0 in 1 ft 4 in Drapes/blinds None 11 SW 3 Metal Low-E Single Yes 1.03 0.29 N 15.0 ft2 5 ft 0 in 1 ft 4 in Drapes/blinds None 12 NW 4 Metal Low-E Single Yes 1.03 0.29 N 16.0 ft2 2 ft 0 in 1 ft 4 in Drapeslblinds None 13 NW 4 Metal Low-E Single Yes 1.01 0.32 N 9.3 ft2 210 in 1 ft 4 in Drapes/blinds None GARAGE # Floor Area Ceiling Area Exposed Wall Perimeter Avg. Wall Height ExposedWall Insulation 1 462 ft2 462 ft2 21 ft 9 ft 13 INFILTRATION # Scope Method SLA CFM 50 ELA EgLA ACH ACH 50 1 Wholehouse ProposedACH(50) .0004 1830.2 100.41 188.5 .1324 7 0 6/2/2021 4:23 PM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 3 of 4 FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT HEATING SYSTEM # System Type Subtype Speed Efficiency Capacity Block Ducts 1 Electric Heat Pump/ None Single HSPF:8.5 35.4 kBtu/hr 1 sys#1 COOLING SYSTEM # System Type Subtype Subtype Efficiency Capacity Air Flow SHR Block Ducts 1 Central Unit/ None Single SEER: 17 35.4 kBtu/hr 1062 cfm 0.75 1 sys#1 HOT WATER SYSTEM # System Type SubType Location EF Cap Use SetPnt Conservation 1 Electric None Garage 0.92 80 gal 60 gal 120 deg Solar SOLAR HOT WATER SYSTEM FSEC Cart # Company Name Collector System Model # Collector Model # Area Storage Volume FEF SRCC 40 APRICUS INC. ETC-30 ETC-30 47.33 ft2 120 gal. 5.4 DUCTS —Supply— V # Location R-Value Area --- Return --- Air Location Area Leakage Type Handler CFM25 TOT CFM25 OUT QN RLF HVAC# Heat Cool 1 Attic 6 333 ft2 Attic 83 ft2 Default Leakage Garage (Default) (Default) 1 1 TEMPERATURES ProgramableThermostat: Y Cooling Jan Feb Mar Venting Jan Feb ki Mar Ceiling Fans: Apr May Jun Jul Jul rl � i Apr I i May Mun riAug Aug Sep riSep M Oct Oct H Nov Nov H Dec Dec ThermostatSchedule: HERS 2006 Reference Schedule Type 1 2 3 Hours 4 5 6 7 8 9 10 11 12 Cooling (WD) AM 78 PM 80 Cooling (WEH) AM 78 PM 78 Heating (WD) AM 66 PM 68 Heating (WEH) AM 66 PM 68 78 78 80 78 78 78 78 78 66 66 68 68 66 66 68 68 78 78 78 78 78 78 78 78 78 78 78 78 78 78 78 78 66 66 68 68 68 68 68 68 66 66 68 68 68 68 68 68 78 78 78 78 68 68 68 68 80 78 78 78 68 68 68 68 80 78 78 78 68 68 68 68 80 78 78 78 68 66 68 66 80 78 78 78 68 66 68 66 MASS Mass Type Area Thickness FurnitureFraction Space Default(8lbs/s .ft. 0 ft2. 0 ft 0.3, Main 6/2/2021 4:23 PM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 4 of 4 NOTE: SEE WINDOW. DOOR, AND FINISH SCHEDULE ON SHEET EV-2 i1 V 1 Osulm j j II II II enaxa_ _. f11CONE .� � Etgf_ r.,► ... MWELMA IN►1 is^� � Ep� f' 0 N N HOUSE FRONT FACING ROAD FLOOR PLAN SCALE: 114' - T-W WA UGEND r� rhG oxw�.zGZF�zrx wuu xlu�lur. I. excnrmz mzbren awaG. ux.cncurtomunuc�rucG wrn ma+nxre.Gunuwurlox. nwcxvii,4vz s*ucm rvvesn. uuv as,ewrn ruxsnm raxrzo Gar+mu GH9N.1 OOnFD EtxrCWK9 i0 a Ix /(%.OgM'Kr.'bnn zIOZ O.IM rnC20t. M40n@SMxnN. COOL. ru.Vcsrww •xGswre Gzvnoranma eoc . nasno neurox wzsl so-n�..+rmwAr.,n n::. szr..n ls. sm�Go-ns.ao msiunmir cnw wz.lm h+..�w�o ru�s�.a zsam,.. s,rwc..cos.. <soar.,. o.m. ca..n a -la r� sr..,x zs. s�o..eavea so ze. srwa si ns p Isa wrtv�wcwws. Iwn r�i lawrr�u,:c ou s°nui'Malsiasnum cw ru e+nvm+, rnl.«oarzwu. <o Gvlxc wan svuwmx wws rox wu.a. SQUARE FOOTAGE: LIVING H/C AREA 1743 SQ. FT. TOTAL H/C AREA 1743 SQ.FT. FRONT ENTRY 134 SO. FT. SCALE: 1/4" = T-0- BACK PATIO GARAGE 216 SO. Fr. 492SQ.Fr. auG TOTALAREA 2585 SQ: FT. 3b1rmn wi TOTAL H/C VOLUME 17,539 CU.FT. w mm 7 JUNE 2p18 I 2017 EPL DFSPLA-Y CARD ENERGY PERFORMANCE LEVEL (EPL) DISPLAY CARD ESTIMATED ENERGY PERFORMANCE INDEX* = 85 The lower the Energy Performance Index, the more efficient the home. 1. New home or, addition 1. New (From Plans) 12. Ducts, location & insulation level a) Supply ducts R 6.0 2. Detached or multiple -family 2. Detached b) Return ducts R 6.0 c) AHU location Garage 3. No. of units (if multiple -family) 3. 1 4. Number of bedrooms 4. 3 13. Cooling system: Capacity 35.4 a) Split system SEER 5. Is this a worst case? (yes/no) 5. No b) Single package SEER c) Ground/water source SEER/COP 6. Conditioned floor area (sq. ft.) 6. 1743 d) Room unit/PTAC EER e) Other 17.0 7. Windows, type and area a) U-factor:(weighted average) 7a. 1.030 b) Solar Heat Gain Coefficient (SHGC) 7b. 0.286 14. Heating system: Capacity 35.4 c) Area 7c. 221.8 a) Split system heat pump HSPF b) Single package heat pump HSPF 8. Skylights c) Electric resistance COP a) U-factor:(weighted average) Ba. NA d) Gas furnace, natural gas AFUE b) Solar Heat Gain Coefficient (SHGC) 8b. NA e) Gas furnace, LPG AFUE f) Other 8.50 9. Floor type, insulation level: a) Slab -on -grade (R-value) 9a. 0.0 b) Wood, raised (R-value) 9b. 15. Water heating system c) Concrete; raised (R-value) 9c. a) Electric resistance EF 0.92 b) Gas fired, natural gas EF 10. Wall type and insulation: c) Gas fired, LPG EF A. Exterior: d) Solar system with tank EF 5.40 1. Wood frame (Insulation R-value) 10A1. e) Dedicated heat pump with tank EF 2. Masonry (Insulation R-value) 10A2. 9.0 f) Heat recovery unit HeatRec% B. Adjacent: g) Other 1. Wood frame (Insulation R-value) 10131. 13.0 2. Masonry (Insulation R-value) 10132. 16. HVAC credits claimed (Performance Method) 11. Ceiling type and insulation level a) Ceiling fans a) Under attic 11 a. b) Cross ventilation No b) Single assembly 11 b. 0.0 c) Whole house fan No c) Knee walls/skylight walls 11c. d) Multizone cooling credit d) Radiant barrier installed 11 d. No e) Multizone heating credit f) Programmable thermostat Yes *Label required by Section R303.1.3 of the Florida Building Code, Energy Conservation, if not DEFAULT. 1 certify that this home has complied with the Florida Building Code, Energy Conservation, through the above energy saving features which will be installed (or exceeded) in this home before final inspection. Otherwise, a new EPL display card will be completed based on installed code compliant features. Builder Signature: Date:, Address of New Home: SEAGRAPE DRIVE City/FL Zip: FT. PIERCE, FL 6/2/2021 4:23:47 PM EnergyGauge® USA 7.0.01 - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 1 of 1 2017 - AIR BARRIER AND INSULATION INSPECTION COMPONENT CRITERIA TABLE 402.4.1.1 AIR BARRIER AND INSULATION INSPECTION COMPONENT CRITERIA Project Name: INDIAN RIVER ESTATES LOT 8 Builder Name: COPPER ENTERPRISES Street: SEAGRAPE DRIVE Permit Office: ST. LUCIE COUNTY City, State, Zip: FT. PIERCE, FL, Permit Number: Y Owner: LOUIS FRISKNEY Jurisdiction: Lu Design Location: FL, Fort Pierce c� COMPONENT AIR BARRIER CRITERIA INSULATION INSTALLATION CRITERIA General A continuous air barrier shall be installed in the building envelope. Air -permeable insulation shall requirements The exterior thermal envelope contains a continuous air barrier. not be used as a sealing material. Breaks or joints in the air barrier shall be sealed. Ceiling/attic The air barrier in any dropped ceiling/soffit shall be aligned with The insulation in any dropped ceiling/soffit the insulation and any gaps in the air barrier shall be sealed. shall be aligned with the air barrier. Access openings, drop down stairs or knee wall doors to unconditioned attic spaces shall be sealed. Walls The junction of the foundation and sill plate shall be sealed. Cavities within corners and headers of frame walls The junction of the top plate and the top of exterior walls shall be shall be insulated by completely filling the cavity sealed. with a material having a thermal resistance of R-3 Knee walls shall be sealed. per inch minimum. Exterior thermal envelope insulation for framed walls shall be installed in substantial contact and continuous alignment with the air barrier. Windows, skylights The space between window/door jambs and framing, and and doors skylights and framing shall be sealed. Rim joists Rim joists shall include the air barrier. Rim joists shall be insulated. Floors The air barrier shall be installed at any exposed edge of Floor framing cavity insulation shall be installed to (including insulation. maintain permanent contact with the underside of above -garage subfloor decking, or floor framing cavity insulation and cantilevered shall be permitted to be in contact with the top side floors) of sheathing, or continuous insulation installed on the underside of floor framing and extends from the bottom to the top of all perimeter floor framing members. .Crawl space walls Exposed earth in unvented crawl spaces shall be covered with Where provided instead of floor insulation, insulation a Class I vapor retarder with overlapping joints taped. shall be permanently attached to the crawlspace Shafts, penetrations Duct shafts, utility penetrations, and flue shafts opening to exterior or unconditioned space shall be sealed. Batts in narrow cavities shall be cut to fit, or narrow Narrow cavities cavities shall be filled by insulation that on installation readily conforms to the available cavity spaces. Garage separation Air sealing shall be provided between the garage and conditioned spac as. Recessed lighting Recessed light fixtures installed in the building thermal envelope Recessed light fixtures installed in the building shall be sealed to the drywall. thermal envelope shall be air tight and IC rated. Plumbing and wiring Batt insulation shall be cut neatly to fit around wiring And plumbing in exterior walls, or insulation that on installation readily conforms to available space shall extand behind piping and wiring, Shower/tub The air barrier installed at exterior walls adjacent to showers and Exterior walls adjacent to showers and tubs shall on exterior wall tubs shall separate them from the showers and tubs. be insulated. Electrical/phone box or The air barrier shall be installed behind electrical or communication exterior walls boxes or air -sealed boxes shall be installed. HVAC register boots HVAC register boots that penetrate building thermal envelope shalt be sealed to the sub -floor or drywall. Concealed When required to be sealed, concealed fire sprinklers shall only be sprinklers sealed in a manner that is recommended by the manufacturer. Caulking or other adhesive sealants shall not be used to fill voids between fire sorinkler cover plates and walls or ceflinas. a. In addition, inspection of log walls shall be in accordance with the provisions of ICC-400. 6/2/2021 4:23 PM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 1 of 1 Planning & Development Services Department Building & Regulations Division RECEIVED Product Review Affidavit JUN 0 4 2021 Building Permit # 0-1 _ 0 � ZZ- Owners Name Applicant: St. Lucl® County Permitting Product Opening Design Pressures Product Rated Design Pressure Manufacturer Model Number Product Approval Number Glass T e Method of Attachment Windows 5 7 A (06' Mullions Fixed Glass Block Glass Skylights Sliding Glass Doors q,d 'I 7� — r Qs�, S60-411MA Swing Type Doors French Doors Garage Doors Hurricane Protection Roof Ventilation Roofing Material Revised 07/22/2014 I have reviewed the above components or cladding and I have approved their use in,this structure. These products provide adequate resistance to the wind loads and forces specified by current code provisions. Name: Signature: seal Design Prof: Cert. No. Date: FILE COPY O CV LQ rim NOTE: SEE WINDOW, DOOR, AND FINISH SCHEDULE ON SHEET EV-2 18'-O" 1 1 '-4" ---------B-2---------� 12" CMU COLUMN 9'-4" FLAT CEILING I PA970 O 1 18 O" X 1 2' O" I I OPEN WITH HIP ROOF I II I1 14'-1 IT 1 I 26-1 " 1 1 12'-1OTT 6'-7" 5'-3" I I 12'-4" 01 7'-6" I I 6'-O" Il II II II /�� „ � <E l L �I nn n nP in, I i <B A CO F- — z w[1W � I � l m I2/ 1O'� t? 3 1 10 I O 15 J I I _ 9FLAT CEE�ILING U 0 (DC} } EDROUwl3 Q I I 104 12' O" X 1 2' 8" 0 W Cv °0 i2x(O X (p LO 02 q I I r r I M �S R I t2DG�M 12 X (DY l Q ii1 12'-2" r I BEDRO M I o0 (20G1�^ 13' 3" X 16 1 O" I � COFFERED O 1 0' I I VC AAU E�D CEILING-%4 L rU NCBROO�btFROM E�,LmwrL 1 9'FLAT EILING I 1 ' 6" X IS' 1 O" 3' . 2''7" 6'_3" N OD 00 4068 BIFOLD ��` HELVE I--------- ---I �__ ----- -------- ---------- N 1 SHELF CV FO FV TUB ACCESS Q 2g0 1 O 3 i1 t VAULTED COLIN AUT 9' FL T �� CEIL INQ BRE219CF�S .,, , c o i l IM ' A 10' O" X 10'25' 1" cn 3 8, O d 1 tt N = (DDO IZ �Q N tt °= tct n N © IZOG,n IZi�(fJX� 3Q o „ m It > 6,_8„ �ZXfDYLP 10'-O" CZ D Q lCk l� 1 SHELF 0) cn 68 106 --i �Jp �I' N B�TF 2 6, .• 1 sH U- 68BIFOL15 LF 1' Q N 0 Inv) 9' FLAT c gO CEILING � fn 2 °v OD CO::I 3 4" 2'-7" 6'-3" io m V• �9.TR N N K VAULTED CEILING - � N _ 4 OSE7 - DIVING z 9' Fc 0� 1 O' O'.' X 1 1' 6" co lD i 4 • 9' ILING CD 109 N A O N to OD 7' O' 1 t " 1 O' 9" os Q m 1 O 1 t7) ¢ N 3 n 3068 rC 10, _ 1 s F o� �?j( W/ FLIT 9' FLAT CEILING O 6'-4" EDROON 2 ; m �' wH 4" STEP Q 2' 0" X 12' 8" N - SERVICE 80gal. Eo sl a' DOWN :` 13'-8" Q DISCONNECT ofwate N wASN .;: '". TT MMEg REFRIG / 3OPLAI FC7RM H. �$�� ' LO 4" STEP DOWN .Y .. CU LINES GARAGE TO HODUSEPARATIONIN ACCORDANCE WITH 302.6 RESIDENTIAL FBC -"1 ('7 O •Jf ...1 �`.��� ATTIC ACCESS O .. 01 5'-2" 5' 10" 4'-8" I 38= r•BLOCKa',• fLO• +' _Y I I Q b © 200 AMP ELECT. ,`• 131-0" I I I METER MAIN U I I� •- EN7RT / O 4 WITH CIRCUITS ���i [ j 9'-4" FLAT CEILING �A��. �y' I I 1 ,. 9 g-4�� FLAT CEILING 1 3,-8„ 16,-1 l}�J 21'O"X20' 10" N 22'-8" m — B-1 N e-- —----- —�J 5 12" CMU COLUMN 8"W 16"D CC CRETE B AM -------------------- \ /'I (3) PLCS. d " I I CONCRETE E TENDS 3" BEYOND COLU AN AND E AMS ' \ 5 16' X 7' OH GARAGE DOOR "''" --` ' •• 3,_4,; 1601' 3'-4" 22'-8" 91.0" 6'-811 110, 52'-01' HOUSE FRONT FACING ROAD FLOOR PLAN SCALE: 1 /4" - 1'-0" • 13'-8" , GENERAL DOTES 1. FIELD VERIFY ALL FIELD DIMENSIONS AND UTILITIES PRIOR TO CONSTRUCTION, 2. VERIFY ANY DISCREPANCIES WITH THE DESIGNER/ CONTRACTOR 3. OPENINGS CLOSE TO INSIDE CORNERS SHOULD HAVE A MIN 4" CLEARANCE TO ALLOW FOR CASING 4. CABIN ETRYAND FINISHES SHALL BE SELECTED BY THE OWNER 5. PLACE EXTRA FURRING AND BACKING TO ALLOW FOR CABINET PLACEMENT AND WINDOW TREATMENTS WALL -LEGEND 0 5" CMU WALLS AND COLUMNS. INTERIOR OF WALLS SHALL HAVE I X PRESSURE TREATED FURRING. ALL UN -GROUTED CELLS WILL BE FILLED WITH EXPANDABLE FOAM INSULATION. EXTERIOR WILL HAVE STUCCO FINISH. INTERIOR WILL BE SMOOTH FINISHED PAINTED DRYWALL. GYPSUM BOARD MATERIALS TO BE IN ACCORDANCE WITH R702.3. I OF THE 2014 FLORIDA RESIDENTIAL CODE. FLAME SPREAD AND SMOKE DEVELOPED INDEX FOR: WALL AND CEILING FINISHES (SECTION 302.9) Sheetrock Gy5pum Panel Flame Spread 15, Smoke -Developed 0 INSULATION (SECTION 302. 10) Icynene R-30 Flame Spread 25 or le55, Smoke -Developed 450 or le55, Owens Cornmg R- 13 Flame Spread 25, Smoke -Developed 50 a 2X4 SPRUCE STUDS @ I G" OC INTERIOR WALLS. 1/2" DRYWALL BOTH 51DES AND PAINTED. MIN R- I I BATT INSULATION SHALL BE INSTALLED ON ALL BATHROOM, LAUNDRY ROOM, AND LIVING AREA SEPARATION WALLS FOR SOUND. SQUARE FOOTAGE: LIVING H/C AREA 1743 SQ. FT. TOTAL HIC AREA 1743 SQ.FT. FRONT ENTRY 134 SQ. FT. SCALE: 1 /411 = 1'-011 BACK PATIO 216 SQ. FT.�� GARAGE 492 SQ. FT. Design By Cooper Enterprises 4.0, LLC TOTAL AREA 2585 SQ. FT. 25 11 SW Regency Rd. Stuart, FI. 34997 IwV4ww.cooperentllc.clonstruction 772-600-5300 TOTAL HIC VOLUME 17,539 CU.FT. 7 JUNE 2018 H CEILING H SIDES. OF 2%) NC. SLAB 4" N 5 o 0 ZO WQ G1 Z 0 co > La W� x p z O Z IL (f) LLJ 0 0 W W W .J O -J (10 O C LLj cV 9 .> .> 00 I� M C %D • �— LZ O USA V M M L. A� W o L L O 0 (a U LL. IL FILE # SHEETA FP-1