Loading...
HomeMy WebLinkAboutRevisions; Screen Enclosure added per buyer requestFILE COPY OFFICE USE ONLY: DATE FILED: REVISION FEE: -$ �03 i s PERMIT # RECEIPT # PLANNING & DEVELOPMENT SERVICES BUILDING & CODE REGULATION DIVISION 2300.VIRGINIA AVENUE FORT PIERCE, FL 34982.5652 (772) 462-1553 APPLICATION FOR BUILDING PERMIT REVISIONS PROJECT INFORMATION LOCATION/SITE ADDRESS: 5609 Myrtle Dr, Ft Pierce, 34982 - Indian River Estates Unit 08 - Block 54 Lot 40 DETAILED DESCRIPTION OF PROJECT REVISIONS: Screen enclosure added per buyer request C ONTRACTORINFORMATION: STATE of FL REG./CERT. #: CBC051145 BUSINESS NAME: GRBK GHO HOMES LLC QUALIFIERS NAME: WILLIAM HANDLER ADDRESS: 590 MERCANTILE PLACE CITY: PORT SAINT LUCIE -STATE: FL PHONE (DAYTIME): 772-773-0075 OWNER/BUILDER INFORMATION: NAME: GRBK GHO HOMES LLC ADDRESS:590 NW MERCANTILE PLACE CITY: PORT SAINT LUCIE PHONE (DAYTIME: 772-773-0075 RECEIVED MAY 1. g 1011 Permitting Department St. Lucie r,)unty ST. LUCIE CO CERT. #: 23565 ZIP: 34986' FAX: 561-688-0909 STATE: FL ZIP: 34986 FAX: 561-688-0909 ARCIHTECT/ENGINEER INFORMATION: NAME: Nuelle Engineering . ADDRESS: CITY: - PHONE (DAYTIME): 561-629-6975 SLCCC. 9123109 Revised 061 O lJ�c 1 STATE: FL ZIP: FAX: COLUMN SCHEDULE MARK 4TY SIZE TYPE DESCRIPTION Bx8 CONC. BILK. W/1 FULLY GROUTED CELL W/1—�5 VERT. EA. CELL C-1 39 BLOCK ®8'-0" 0/C MAX. OR AS LOCATED ON PLANS 6 8x16 CONC. BLK. W/2 FULLY GROUTED CELLS W/1—#5 VERT. EA. CELLBLOCK L-2 2 8x12 CONC. BILK. W/1 FULLY GROUTED CELL W/2—�5 VERT. BLOCK PROJECT LOG CONC. POURED FILLED CELL TYP. HOLLOW ISSUED FOR PRECON 07-21-20 51t. PER PLAN MASONRY BLOCK ISSUED FOR PERMIT 08.14.20 RUNNING BOND PER PLAN 1 BUYER LATE CHANGE 11-12-20 2 BUYER LATE CHANGE 05-06-21 DOWELL & EPDXY (1) #5 REBAR 7Z INTO SLAB 0 FILLED CELL LOCATION W/ 4° MIN. EMBED. INTO SLAB N CONC. SLAB & MONOUTHIC - - - - FOUNDATION PER PLAN MISSED COLUMN 0 STL. DETAIL Lq TE-2 A4 TE-2 i a 48 BAR DIA. SPLICE I LL N J 5 ' 0. W J111 Z + . • •r ¢. I 2 ._4. 1 14'-¢* a w3 �....`J: I W W a,'. ?• • .;.j : ", 7'-2" 7'-2 7'-D" 14'-4" 7_2 7'-2" w Z o 7 N LL Z. 8" MATCHING DOWELS FOR 8" MATCHING DOWELS FOR Y I p m COLUMN 48 BAR DIA. �1';. I MIN. 48��DIA. 8"x8' PRECAST I I ° Q MIN. Wl 7s HOOKS / } LINTEL. SEE LINTEL HB Z o N FlBERMESH OR FlBERMESH OR < 4 Y�8. ® C2 I I 2 5 HEAD WELDED WIRE MESH '� WELDED WIRE MESH f SHOP DWGS. ■ ■ �/ 8 O' ■ ■■ PAVERS ■■ 6-0" ■ ® a TRANSVERSE REBAR a FILL COLUMNS n WHERE OCCURS S Y AND LINTEL SOLID } SEE FOOTING SCHED. �EREWRSEEBAR W/ GROUT - - - - - - - - - - - - } . OCCURS SEE F TT SCHED. I Fl F, "- "• f�'y 8"x8' FILLED CELLS w/ 1 I I z VERT. (TYP. rnLn I I m TYPICAL DETAIL i I 8'-8" 5'-s° o o LINTEL ON COLUMN ■ I F1 I ■ ■ F1 ■ a� _ SCHED. SCHED. " L-. 2 0 y O38 I I c HE ®� c2 N +' 3 c7 (n cn G EXT. CONT. MONOLITHIC I i B' p" .-> m ad (D CU FUTUREA I L-------------------------------J n t° 1 ay a SCREEN FASTENERS BY C c -o v MESH ENCLOSURE SCREEN MFGR. I F1 n V w LU 1- CONT. BY SCREEN PAVERS IN SAND ■ I O F1 ■ N �o� 2 o c O m 3' MN. COVER 10° CONTRACTOR BY OTHERS I Fl �i g H p En m 34 THICKENED EDGE #1 FINISH GRADE I _ 0'-0' FIN. FLOOR SLAB 1 Lnn w o I _ Ln Y ae " 8° x 8" CONT. "� o I H t 0 `�° c� ce 0 CONIC. FTG. i REINFORCE W/ I ° NOTE: 1 -o A 1#5 CONT. ■ I ALL FOOTINGS ARE F1 U.N.O. 1 ■ SCREEN ENCLOSURE j a ° ALL COLUMNS ARE Cl U.N.O. �4 FORM SHOWER PAN FTG. DETAIL I , 1SID LARGER AC ALL � I �I 0 1�_g• SIDES THAN ACTUAL TE-1 8" 6' I FINISHED SHOWN HERE — — — r " MASONRY WALL BEYOND _ O •� 0 OVERHEAD GARAGE DOOR I SUPPLY U.G. POWER PAVER RECESS I & WATER TO ISLAND a° F2 o N CONC. BRICK PAVER OHD RECESS I o I a-� Tn SET IN SAND , ■ oo In SLOPE PER SURVEY xo `� lA fit .� S'. V FOOTING SEE SCHEDULE m `p+ y "' I I o� _ _ o o ° to 0 5'-3° � 2'- " {} o _ A/C CONDENSATE 20' O ° o I UNDER SLAB O❑ �� d 1 i DRIVEWAY / GARAGE INTERSECTION I I Z U wm QL--J Ln NOTE: FORM GARAGE SIDE DEMISING WALL O C%4 ■ I RECESS 1-1/2° SMALLER THAN ACTUAL = CV d i 4 FINISHED DIMS SHOWN HERE - PC a a I I J�J N G ■ I F1 _ 20'-0" "VISION V ISION I�.. COP o I I' 8' W X 5-" D RECESS i I ■ "� ® FOR PAVERS (FOOTING I g\j DEPTH MEASURED FROM ELE T. & CHAS� � (//�—(/tom ° I BOTTOM OF RECESS) W/ FRAME HAt r jjV W EU F -1 I I a 1 6' W X 3/4° D RECESS SEE DTL. SHEET A-(L BEHIND (SLOPED) a CODE COMPLIANC M ■ I F1 i F1 1 ST. LUCIE COUNT ° I i---------J �� U_ SOCC � } ■■ ■■ ■ CcF— a I ■ ■ ■ sTEP FT C2 A C2 V . uT®c LU O L--------- --- ---------I N U p[ Uj ■ ■ ■ ■ ■ � C OHEID 0 HEA ® G =J 8 O" 8" H O J �J Ln 1/4" = V-O" U.N.O. 11'-2° 6'-1" 2' 4" 2'-4` V-4' 16,-0" 2'-0° RECEIVED 23'-4" 5'-4° 2'-0' 19'-4' 5'-0• MAY is loll FOUNDATION permitting Department St. Lucie County A4 -- A-1 BLOCK ISOMETRIC VIEW MYRTLE WALL HEIGHT AT 9'-4° TYPICAL _-•-,r7,/ SCALE IS 1/8° : 1' v r" PSL 0 FOOTING SCHEDULE MARK SIZE WxD REINFORCING DESCRIPTION DETAIL N0. F-1 20' x 18" W/2 /5 CONT 8)M. EXTERIOR MONOLITHIC TYPICAL 1 F-1 20' x 18" W/2 ,�5 CONT. BTM. EXTERIOR MONOLITHIC ®RECESS 38 -i " x x CONT 1 THICKENED EDGE R 3 7E-2 8' x 8" x CONT. W/i/5 CONT. THICKENED EDGE AT SCREEN ENCLOSURE 59 FIXTURE SCHEDULE OTY NAME 1 DBL. KIT. SINK 1 DISH WASHER 3 LAV BOWL 2 SHOWER VALVE 2 TOILET 1 TUB 1 WASHER CALCULATIONS TOTAL U/A 1841 S.F. COVERED ENTRY COVERED PATIO GARAGE TOTAL AREA 41 S.F. 188 S.F. 432 S.F. 2502 S.F. FAN ADDITIONAL NOTES, 1. STANDARD HOLLOW CORE RAISED PANEL DOORS. 2. TILE TO 7'-0' IN MASTER SHOWER AND 7'-0" IN OTHER LOCATIONS. 3. FIBERGLASS BOARD OR DUR-O-ROCK TO 7'-0" A.F.F. OR SOFFIT AROUND TUBS/SHOWERS AND TO 4'-0" A.F.F. 0 MARBLE TUBS 4. ROUNDED CORNERS AT ALL LOCATIONS EXCEPT CLOSETS, SLIDERS, WINDOWS, DOORS, VERTICAL EDGES OF CEILINGS OR AS NOTED ON PLANS. 5. KNOCKDOWN CEILING TEXTURE AND ORANGE PEEL WALL TEXTURE. 6. R-40 BLOWN IN INSULATION AT ALL A/C AREAS 7. IMPACT ALL WINDOWS. IMPACT / LOW E GLAZING AT WINDOWS AND SLIDING GLASS DOORS TOTAL AIR VOLUME CUBIC FEET = 23697.1 U VALUE SHGC TYP. WINDOW IMPACT .62 / .25 VERTICAL HEIGHT SEPARATION IS 8" WINDOW SCHEDULE NUMBER SIZE DESCRIPTION WIDTH HEIGHT 1 4'-5" 6'-0" SH 36 EGRESS 2 4'-5" 6'-0" SH 36 EGRESS 3 2'-4" 3'-2" SH H33 TEMP 5 9'-O" 5-3" 2 SH 35 EGRESS - - P R-40 BLOWN -IN FIBER GLASS INSULATION AT ALL A/C AREAS ALL INSULATION SHALL COMPLY WITH FBC R302.10 FLAME SPREAD COMPLIANCE 25. SMOKE DEVELOPED INDEX 50. ALL CEILING AND WALL FINISHES SUCH AS PAINT SHALL COMPLY WITH FBC R302.9.1 Et R302.9.2 FLAME SPREAD INDEX NOT GREATER THAN 200. SMOKE DEVELOPED INDEX NOT GREATER THAN 450. FINISHED CEILING OPT. 2x WD BLOCKIN( EACH SIDE OF N FOR MOUNTING 2x MTL. STUDS TYP. FINISHED FLOOR TYP. MEDICINE CABINET GARAGE CEILING 15' EXT. DOOR SCHEDULE LETTER SIZE DESCRIPTION WIDTH HEIGHT A 16'-0" 7'-0" OHD. B 4'-6" 8'-2" 3080 EXT. DR. W/SIDELITE (MAIN EGRESS) C 8'-0" 8'-01, SGD. INT. DOOR SCHEDULE LETTER CITY SIZE DESCRIPTION WIDTH HEIGHT D 7 2'-8" 8'-0" INT. DR. E 4 2'-6" 8'-0" INT. DR. F 2 6'-0" 8'-0" INT. BIPASS DR. G 2 1'-6" 8'-0" INT. DR. (2) 110 SM.S. TOP & BOTTOM 0 EACH STUD FINISHED CEILING - SEE TYP. WALL SECTION 2x6 BLOCKING 0 CABINET LOCATIONS. FASTEN EA. END TO STUDS W/ (2) 110 S.M.S. EA. END 25 GAUGE CHANNEL SHAPED STUDS- 24X40/C) W/1 FULLSTUDS 0 16"OLLECNGTH 6 A RO OF 1/2- TYPE GYPSUM WALLBOARD APPLIED VERTICALLY & ATTACHED W/ 1" LONG BUGLE HEAD SCREWS TO EACH SIDE 0 12' 0/C CONT. 25 GAUGE METAL TRACKS TOP & BOTTOM CONC. FLOOR SLAB HILTI PINS .145" DIA x 1" LG. 0 16' 0/C W/ 1" WASHERS TYPICAL INTERIOR PARTITION ALONG CABINETRY BACKING SCALE 3/4' = 1'04 (2) 110 SM.S. TOP & BOTTOM 0 EACH STUD FINISHED CEILING - SEE TYP. WALL SECTION CONT. 25 GAUGE METAL TRACKS TOP & BOTTOM W/ (1) #10 SMS 0 24° 25 GAUGE CHANNEL SHAPED STUDS 24" O/C W/1 FULL LENGTH LAYER OF 1/2" TYPE GYPSUM WALLBOARD APPLIED VERTICALLY & ATTACHED W/ 1" LONG BUGLE HEAD SCREWS TO EACH SIDE 0 12° 0/C CONC. FLOOR SLAB HILTI PINS .145° DIA x 1" LG. 0 16" 0/C W/ 1' WASHERS 1 INTERIOR PARTITION A.2 3/4" =1,-D" CEILING 16" TYPICAL FRAMING 0 16' O.C. z FLOOR RO CEILING a ELECT. PANEL o 0 BACK TO o o BACK W/ 7, METER N w J w U O GARAGE FLOOR FINISHED FLOOR ELECT. PANEL / CHASE SOAP NICHE .1 N 7 W-6' WASHER DRY R O 28-1/2-1PPACE DRYER VENT i n AC 12' _. DRYER VENT LOCATION FRONT VIEW AC CONC, PAD DETAIL SCREEN ENCLOSUREA2 14'-4" 2''-4- 14'-4" 7'-2" 7'-2" 7'-0' 14'-4" 7' 2" 7'-2" O HB p 5'-B`L DBL OVEN CAE - - 160 a `6 o o �F — — — b o m DINING 9'-4" CLG. 2'-0' 1'-8" 3'-4' BACKING 0 36` 1r— J - 96" A.F.F. I N 1 3 z'� J fi m n Dw I " JII LL — KITCHEN 9'-4" CLG. 10'-10' 3'- ` — — — — — — — — — — — — V. PA I 9'-4" CLG. ABV. MAIN SLAB — — — — — — — — — o ASTER SUITE 9'-4" CLG. 13'-0° o 15'-4° 11= • , 3'-4` ° 3'-0' m 3'-0" 7'-4- 2'-2' L N I — N E R WI E 2-2" °0 GREAT ROOM 10'-8" CLG. 8'-8° 4'-10' 1'-B' 3'-6" - HIS 5 SH. N 0" V2°-2" 4'-8' I im MASTER 9'- BAT G " CLG. OAP NIC E _ ° I ANITY 96" jf _ ° ' N D D =+ e Y N r 5 SH. — ° 2 fi' 8'8° H R. BA "O 73-711 0 LG.� UTILITYN �G� m 4" 1'-10" �-/3'-4 3'- ' 9'-4" CLG. " D µ ° 7'-2- n D . U D N N D v 3'-4' 3'- " 7'-6- o -N 20 MIN. SOLID CORE ° GARAGE SEPERA E DOOR W/ RABBITTED PER F.B.C. R302. JAMB OVERSIZED WEATHERSTRIPPING N� a ��J EWH — — — — , co 8'8' HDR. — ID 6'-0' 5' D I'-4" ° N 9'-4 I FOYERPROVIDE / 10'-4; FF. A 2" STL BOLLARD W/ 6 x 6 x 3/8" BASE PLATE ATTACHED TO SLAB W/ (3) 3/8°0 W.A.B W/ WASHERS 4' LG. FIELD VERIFY c SMOOTH COAT LOCATION TO PROTECT N4i PER F.B.0 N STUCCO FINISH TWO BAY GARAGE EXCEPT AT DRYWALL LINE OF OVERHEAD DOOR EL I SEE D. I CT. & CH SE FRAME -'JUT SHEET 'JUT I R AB o N BEDROOM 2 9'-4" CLG. 1o'-1a' o N BEDROOM 3 9'-4" CLG. 10'-10• OV• 13'-"CL. ABV. MAIN — D" %el �J N^ S A O O 2' 4" V-4" 2'-0' 1'-4' 16,-0" 2'-D' 23'-4" 5'-4" 19'-4" 8" d �11 a b REVISION EI LE COPY 20 to ODE COMPLIANCE ;ST. LUCIE COUNTY pummcc � PROJECT LOG ISSUED FOR PRECON 07-21-20 ISSUED FOR PERMIT 08-14-20 BUYER LATE CHANGE 11-12-20 BUYER LATE CHANGE OS-08-21 Ld 11 S W m J � o Wa LLILj LL J W z 7)w J LL I O ® K r a W o Q O a an 01 m C O -0� Q�= O amo o, `mow cu �o'wn .0 rc = -O c0 3: ur n > m � 2 �-wa o n aY3`i o m cc o+, a�i c cn c� 150 o o ro w FA to Er S, o e " 'wn cn mpC=) vi w o '4@ Y Hvbi cOi ` Ca zu�5 Z 0 ce U- m z O Lu M U ICI W U J O LL O U O J OJ i L`n c 114" = 1'-n" I I N n FLOOR PLAN A-2 MYRTLE PSL 40