Loading...
HomeMy WebLinkAboutREVIEWED, 5304 OAKLAND LAKE CIR-MANUAL JCalculations approved by ACCA to meet all requirements of Manual J 8th Ed. 2021-Jun-15 13:37:53 Right-Suite® Universal 2021 21.0.07 RSU08101 Page 1 ...AC\GARAGE MINI SPLIT-5304 OAKLAND LAKE CIR..rup Calc = MJ8 Front Door faces: N Job:Project Summary Date:Entire House By: QUICK CALCS, INC. 317 ST. LUCIE LANE, FT. PIERCE, FL 34946 Phone: 772-466-6799 Email: QUICKCALCS@AOL.COM Project Information GARAGE MINI SPLITFor:5304 OAKLAND LAKE CIRCLE, FT. PIERCE, FL Notes: Design Information Fort Pierce, FL, USWeather: Winter Design Conditions Summer Design Conditions Outside db °F42 Outside db °F90Inside db °F70 Inside db °F75 Design TD °F28 Design TD °F15Daily range M Relative humidity %50Moisture difference gr/lb61 Heating Summary Sensible Cooling Equipment Load Sizing Structure Btuh9530 Structure Btuh10039 Ducts Btuh1551 Ducts Btuh2011Central vent (0 cfm) Btuh0 Central vent (0 cfm) Btuh0 (none) (none)Humidification Btuh0 Blower Btuh0 Piping Btuh0Equipment load Btuh11081 Use manufacturer's data n Rate/swing multiplier 0.95InfiltrationEquipment sensible load Btuh11447 Method Latent Cooling Equipment Load SizingSimplified Construction quality Average0Fireplaces Structure Btuh2136 Ducts Btuh616Central vent (0 cfm) Btuh0 CoolingHeating (none)420420Area (ft²) Equipment latent load Btuh2752 42004200Volume (ft³)Air changes/hour 0.320.61 Equipment Total Load (Sen+Lat)Btuh14199 Equiv. AVF (cfm) 2243 Req. total capacity at 0.70 SHR ton1.4 Heating Equipment Summary Cooling Equipment Summary Make Carrier Make CarrierTrade CARRIER Trade CARRIER Model 38MARBQ18AA3 Cond 38MARBQ18AA3AHRI ref 206348137 Coil 40MAHBQ18XA3 AHRI ref 206348137Efficiency 13 HSPF Efficiency 12.5 EER, 21.5 SEER Heating input Sensible cooling Btuh12600Heating output Btuh @ 47°F17400 Latent cooling Btuh5400 Temperature rise °F26 Total cooling Btuh18000Actual air flow cfm600 Actual air flow cfm600 Air flow factor cfm/Btuh0.054 Air flow factor cfm/Btuh0.050Static pressure in H2O0 Static pressure in H2O0 Space thermostat Load sensible heat ratio 0.81Capacity balance point = 31 °F Backup:Input = 3 kW, Output = 9078 Btuh, 100 AFUE Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. 2021-Jun-15 13:37:53Right-Suite® Universal 2021 21.0.07 RSU08101 Page 1...AC\GARAGE MINI SPLIT-5304 OAKLAND LAKE CIR..rup Calc = MJ8 Front Door faces: N Job:Right-J® Worksheet Date:Entire House By:QUICK CALCS, INC. 317 ST. LUCIE LANE, FT. PIERCE, FL 34946 Phone: 772-466-6799 Email: QUICKCALCS@AOL.COM 1 Room name Entire House GARAGE 2 Exposed wall 82.0 ft 82.0 ft 3 Room height 10.0 ft 10.0 heat/coolft 4 Room dimensions ft20.0x21.0 5 Room area 420.0 ft²420.0 ft² Ty Construction U-value Or HTM Area (ft²)Load Area (ft²)Load number (Btuh/ft²-°F)(Btuh/ft²-°F)(Btuh/ft²)(Btuh/ft²)or perimeter (ft) (Btuh)or perimeter (ft) (Btuh) Heat Cool Gross N/P/S Heat Cool Gross N/P/S Heat Cool 6 WW 13AB-0ocs13AB-0ocs 0.2580.258 nn 7.227.22 4.494.49 210 91 657 409 210 91 657 409 .DD 11J011J0 0.6000.600 nn 16.8016.80 15.9015.90 119 119 1999 1892 119 119 1999 1892 .WW 13AB-0ocs13AB-0ocs 0.2580.258 ee 7.227.22 4.494.49 200 200 1445 898 200 200 1445 898 .WW 13AB-0ocs13AB-0ocs 0.2580.258 ww 7.227.22 4.494.49 10 10 72 45 10 10 72 45 11 PP 12C-0sw12C-0sw 0.0910.091 --2.552.55 1.061.06 400 379 966 400 400 379 966 400 DD 11D011D0 0.3900.390 nn 10.9210.92 10.3410.34 21 21 229 217 21 21 229 217 CC 16B-19ad16B-19ad 0.0490.049 --1.371.37 2.452.45 420 420 576 1029 420 420 576 1029 FF 22A-tpl22A-tpl 0.9890.989 --27.6927.69 0.000.00 420 82 2271 0 420 82 2271 0 6 c) AED excursion 0 0 Envelope loss/gain 8216 4889 8216 4889 12 a) Infiltration 1314 369 1314 369 b) Room ventilation 0 0 0 0 13 Internal gains: Occupants @ 230230 6 1380 6 1380 Appliances/other 3400 3400 Subtotal (lines 6 to 13)9530 10039 9530 10039 Less external loadLess external load 0 0 0 0 Less transferLess transfer 0 0 0 0 RedistributionRedistribution 0 0 0 0 14 Subtotal 9530 10039 9530 10039 15 Duct loads 16%20%1551 2011 16%20%1551 2011 Total room load 11081 12049 11081 12049 Air required (cfm)Air required (cfm)600 600 600 600 Job #: Performed for: GARAGE MINI SPLIT 5304 OAKLAND LAKE CIRCLE FT. PIERCE, FL QUICK CALCS, INC. 317 ST. LUCIE LANE FT. PIERCE, FL 34946 Phone: 772-466-6799 QUICKCALCS@AOL.COM Scale: 1 : 85 Page 1 Right-Suite® Universal 2021 21.0.07 RSU08101 2021-Jun-15 13:38:19 ...SPLIT-5304 OAKLAND LAKE CIR..rup N Sheet 1 GARAGE EXISTING 18,000 BTU MINI SPLIT SYSTEM 2021-Jun-15 13:37:53 Right-Suite® Universal 2021 21.0.07 RSU08101 Page 1 ...AC\GARAGE MINI SPLIT-5304 OAKLAND LAKE CIR..rup Calc = MJ8 Front Door faces: N Job:Duct System Summary Date:Entire House By: QUICK CALCS, INC. 317 ST. LUCIE LANE, FT. PIERCE, FL 34946 Phone: 772-466-6799 Email: QUICKCALCS@AOL.COM Project Information GARAGE MINI SPLITFor: 5304 OAKLAND LAKE CIRCLE, FT. PIERCE, FL CoolingHeating External static pressure in H2O0in H2O0 Pressure losses in H2O0in H2O0 Available static pressure in H2O0in H2O0 Supply / return available pressure 0.000 / 0.000 in H2O in H2O0.000 / 0.000 Lowest friction rate in/100ft0in/100ft0 Actual air flow cfm600cfm600 Total effective length (TEL) ft0 Supply Branch Detail Table Design Htg Clg Design Diam H x W Duct Actual Ftg.Eqv Name (Btuh)(cfm) (cfm)FR (in)(in)Matl Ln (ft)Ln (ft) Trunk 00VlFx0x00060060012049cGARAGE Return Branch Detail Table Grille Htg Clg TEL Design Veloc Diam H x W Stud/Joist Duct Name Size (in) (cfm)(cfm)(ft)FR (fpm)(in)(in)Opening (in) Matl Trunk rb1 0x 6000 600 0 0 0 0 x0 0 VlFx